Altinex Network Card CP451 008 User Manual

SPECIAL APPLICATION  
CP451-008 shown with optional docking cradle.  
MANUAL PART NUMBER: 400-0518-001  
CP451-008  
MULTITOUCH WIRELESS  
TOUCH SCREEN CONTROLLER  
USER’S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
1.4 FCC NOTICE  
PRECAUTIONS / SAFETY WARNINGS  
1
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
Please read this manual carefully before using your  
CP451-008 and keep it handy for future reference.  
These safety instructions are to ensure the long life  
of your CP451-008 and to prevent fire and shock  
hazards. Please read them carefully and heed all  
warnings.  
1.1 GENERAL  
·
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
·
Do not open the unit or power supply case, there  
are high-voltage components inside.  
·
There are no user serviceable parts inside.  
Qualified ALTINEX service personnel must  
perform all service on the CP451-008.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and if  
not installed and used in accordance with  
instructions found herein, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
·
Handle the CP451-008 carefully.  
1.2 HANDLING  
·
For best results, place the CP451-008 in a dry  
area away from dust and moisture.  
·
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the  
CP451-008 in direct sunlight, near heaters, or  
heat-radiating appliances, or near any liquid.  
Exposure to direct sunlight, smoke, or steam can  
harm internal components.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
·
·
·
·
Handle the CP451-008 carefully. Dropping or  
jarring can damage the unit.  
Do not pull any cables that are attached to the  
CP451-008.  
Do not place heavy objects on top of the  
CP451-008.  
If the CP451-008 is not used for an extended  
period, disconnect the adapter from the wall to  
avoid fire, shock, and loss of power.  
1.3 CLEANING  
·
·
Unplug the CP451-008 adapter before cleaning.  
Clean only with a dry cloth. Never use strong  
detergents or solvents such as alcohol or  
thinner. Do not use a wet cloth or water to clean  
the unit. Do not open the unit to clean.  
400-0518-001  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
The CP451-008 is small, lightweight, and powerful.  
It can easily be carried from room to room and used  
to control several devices on one or more wireless  
networks.  
ABOUT YOUR CP451-008  
2
CP451-008 SERIES  
Wireless Touchscreen Controller  
AVSnap is preinstalled on each CP451-008 making  
it easy to integrate into any control environment.  
AVSnap provides a complete environment for  
designing simple to sophisticated graphical user  
interfaces (GUIs). Design high-quality GUIs with  
minimum effort by way of user-friendly toolbars for  
buttons, volume controls, progress bars, and much  
more. AVSnap incorporates a simple programming  
language with an organized interface that makes  
even complex programming code easy to read and  
maintain.  
The CP451-008 touch screen controller is ideal for  
a great many applications including multimedia  
control systems, general computing, real-time data  
terminals, etc. Each controller runs Windows XP  
Embedded and includes these key features:  
· Battery Powered  
· Wireless Local Area Network (WLAN)  
· Bluetooth Personal Area Network (PAN)  
· Enhanced Write Filter (EWF) Protection  
· AVSnapProfessional AV System Integration Tool  
Everything needed to start is included in a sample  
application. Use the predefined procedures and  
functions to communicate with devices over the  
WLAN, or create your own custom subroutines. If  
you can program Crestron or AMX, you can  
program AVSnap.  
The CP451-008 senses “touch” from a finger,  
stylus, pen, pencil, gloved finger, or other tool. The  
touch screen is very accurate and responsive to the  
touch. The CP451-008 incorporates effortlessly into  
PC based control systems.  
The EWF prevents changes to the internal drive  
without specific intent and access. This protects the  
BIOS and operating system files from becoming  
corrupt due to power outages or other power  
interruptions.  
Since the CP451-008 can run on battery power,  
most setups use the WLAN feature. For added  
flexibility, consider the ALTINEX AC301-201  
TCP/IP to RS-232 Adapter. This adapter allows  
RS-232 communication through a standard LAN  
connection. Place the AC301-201 on an RS-232  
controlled device and then connect it to a wireless  
router for an instant wireless network.  
The AC404-101 is an optional docking cradle  
available for the CP451-008 that includes 2 USB  
ports, an Ethernet/LAN (RJ-45) port, and an input  
for DC power. Power is provided to the cradle using  
the power adapter supplied with the unit. The USB  
and LAN ports make the cradle an ideal base  
station that allows for a permanent LAN connection  
as well as inputs for a USB keyboard and mouse.  
When not in use, the CP451-008 can be placed  
back on the cradle for charging.  
The AC301-201 has both serial (DB9) and network  
(RJ-45) connections. The AC301-201 connects to a  
serial device using its DB9 connection, and to the  
LAN using standard network cable. AVSnap,  
HyperTerminal, or other RS-232 communication  
software can then be used to control the serial  
device using the IP address of the adapter in place  
of the COM port. In this way, a single controller can  
be used to control any number of serial devices  
using their unique IP address.  
The Bluetooth module inside each CP451-008 is  
compatible with most peripheral devices like  
headsets, barcode readers, printers, cell phones,  
and more.  
400-0518-001  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
TECHNICAL SPECIFICATIONS  
3
MECHANICAL  
CP451-008  
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
Magnesium-Aluminum  
Alloy  
Enclosure  
FEATURES/  
CP451-008  
Color  
Black  
7.9 in (200 mm)  
9.6 in (240 mm)  
0.9 in (23 mm)  
2.0 lb (0.9 kg)  
3.1 lb (1.4 kg)  
0-40°C  
DESCRIPTION  
Height  
Details  
Width  
LCD Size  
Resolution  
Colors  
8.4”  
800 x 600 max.  
32 bit  
Depth  
Weight  
AMD Geode™ LX 800  
500 MHz  
CPU  
Shipping Weight (approx.)  
T° Operating  
T° Maximum  
Humidity  
RAM  
512 MB  
802.11 b/g  
WLAN  
60°C  
PAN  
Bluetooth  
90% non-condensing  
40,000 hrs (min.)  
Solid State Drive (SSD)  
External Connections  
External Battery  
Docking Bay  
USB  
CF Type II, 1GB  
MTBF (calculations)  
7-pin (1)  
9-pin (1)  
Table 2. CP451-008 Mechanical  
ELECTRICAL  
CP451-008  
Type A F (1)  
DC Jack (1)  
3.5 mm F (1)  
3.5 mm F (1)  
External Connections  
USB 2.0 Voltage  
USB 2.0 Current  
LAN Speed  
12VDC  
Microphone  
Headphones  
Agency Approval  
EMC  
5V  
100 mA max.  
10/100 Mbps  
(from adapter)  
42 W max.  
FCC Class B  
UL, CE  
Power Consumption  
+12VDC  
Safety  
Accessories Included  
Internal Battery  
Li-Ion 14 W  
+12VDC  
Table 3. CP451-008 Electrical  
Power Adapter+  
AC Power Cord  
Stylus  
Non-electronic  
Optional Accessories  
Docking Cradle with  
USBx2, 12 VDC In, LAN  
AC404-101  
AC404-102  
Desktop Stand  
Table 1. CP451-008 General  
400-0518-001  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
PRODUCT DESCRIPTION  
4
Power/Charging LED  
Microphone  
Network LED  
Stylus  
Headphones  
Microphone In  
Power  
Switch  
Brightness  
Control  
USB Port  
+12VDC In  
Speaker  
Docking Port Connector  
400-0518-001  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
400-0518-001  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
DIAGRAM 2: DIMENSIONS  
400-0518-001  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
DIAGRAM 3: AC404-101 (OPTIONAL)  
Height............ 3.0 in (76 mm)  
Width............. 6.5 in (165 mm)  
Depth............. 7.7 in (196 mm)  
Weight........... 1.3 lb (0.6 kg)  
The docking cradle uses the CP451-008’s power  
supply as its input power source. The cradle makes  
an excellent charging station as well as providing  
an Ethernet port and 2 additional USB ports. A  
network connection, USB keyboard, and USB  
mouse can be permanently attached to the cradle  
making it a central base and charging station.  
400-0518-001  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
INSTALLING YOUR CP451-008  
6
CONTROL SOFTWARE SET UP  
Step 1. The CP451-008 only requires power to be  
operational. If using the docking cradle,  
determine the best location for installation.  
The docking cradle should be centrally  
located to the CP451-008’s operational  
area so users will remember to return the  
unit to the cradle for charging. One power  
adapter is shipped with the CP451-008.  
This power adapter can power either the  
cradle or the CP451-008.  
Step 1. Prepare the control software using your  
normal software development station. The  
CP451-008  
is  
not  
required.  
We  
recommend using AVSnap as the control  
software. It is free, easy to use, and has  
many features designed for use with the  
CP451-008.  
Step 2. Debug the control software using the  
device for which it was written. The  
CP451-008 is a normal computer and its  
LAN/WLAN ports work the same as a  
desktop computer.  
Additional power adapters can be  
purchased if the CP451-008 is continually  
used for long periods away from the  
docking cradle. In this case, a second  
power adapter can be used at remote  
locations while not disturbing the docking  
station setup.  
Step 3. When the control software is complete,  
copy all necessary files to a USB drive.  
Step 4. Start the CP451-008 and then escape out  
of the AVSnap demo application and  
return to the desktop.  
ADDITIONAL CONSIDERATIONS  
·
If the CP451-008 connects to the  
network through the docking cradle,  
LAN access and a network cable are  
required.  
Step 5. Install the USB drive into the CP451-008  
and copy the files over to the “C” drive. If  
any application software is required,  
install it at this time. Once all the software  
has been installed, close all open  
applications and run the COMMIT batch  
file located on the desktop. This will  
commit the changes made to the internal  
drive.  
·
Make sure there is access to the USB  
ports. One USB port is accessible  
from the side of the CP451-008 and  
there are 2 USB ports accessible from  
the back of the docking cradle.  
NOTE: If an installation wizard requests a restart  
to complete the installation, answer NO.  
The COMMIT batch file must be run first.  
Step 2. Route all cables required for the  
CP451-008 to the installation location.  
Make sure the cables are long enough to  
allow for service loops and to be routed  
neatly to their destinations.  
Step 6. Restart the CP451-008 and verify all the  
changes are present. Place a shortcut to  
the new control software into the startup  
folder and remove the AVSnap demo.  
Run the COMMIT batch file again and  
restart the CP451-008.  
Step 3. Press the power switch on the side of the  
unit to turn power on. The unit will start  
Windows and then automatically launch  
the AVSnap demo application.  
Step 7. The unit is now operational. Verify the  
CP451-008 boots up and automatically  
launches the new control software.  
400-0518-001  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
7.3 INSTALLING FILES AND APPLICATIONS  
OPERATION  
7
The CP451 utilizes the Windows XP Embedded  
EWF to protect its internal drive from accidental or  
unauthorized changes. The EWF appears to read  
and write from the internal drive, but executes  
everything in RAM. All changes WILL be lost after  
reset or shutdown unless the changes are  
committed to memory. Three batch files are  
provided for direct control over the EWF and should  
be used cautiously.  
The CP451-008 is designed for use in a fixed  
application where the system boots up directly into  
the user application and does not allow access to  
the operating system. The application and GUI  
interface are normally created using a standard  
desktop computer and then installed onto the  
CP451-008 using a USB drive or network  
connection.  
Once set up, the CP451-008 will work trouble-free  
1. COMMIT.BAT – Write to hard drive  
without user intervention.  
This batch file resides on the desktop and writes  
the RAM data onto the hard drive for permanent  
storage while EWF is enabled. Close open  
applications before running this batch file or the  
changes may not be committed to memory.  
7.1 POWER UP and SHUTDOWN  
In most installations, the system boots directly into  
the end-user application the same as the default  
demo application.  
The CP451-008 can be powered down using the  
shutdown/power off option from the START menu,  
or directly from an AVSnap application using the  
“App.Shutdown” function.  
2. ENABLE.BAT – Turn on EWF  
This batch file resides in the root directory and  
turns on the EWF. In this mode, no changes  
made to the system are saved unless the  
COMMIT batch file is executed. This is the  
default condition for all CP450s.  
7.2 PREPARING CONTROL SOFTWARE  
It is not recommended to design and create control  
software directly on the CP451-008. In most  
situations, it is easier and faster to write and debug  
control software on a standard desktop computer  
and then transfer the completed file when ready.  
However, if the CP451-008 needs to be  
programmed “in place”, use an external USB  
keyboard and mouse. Simply plug in the devices  
and wait for the system to recognize the new  
hardware and load the drivers.  
3. DISABLE.BAT – Turn off EWF  
This batch file resides in the root directory and  
turns off the EWF. In this mode, the system  
operates like a normal computer reading and  
writing data directly to the hard drive.  
WARNING  
When the EWF is turned off, the user MUST  
shutdown the computer properly. If power is  
turned off or lost without executing the normal  
shutdown procedure, data can be lost, or  
corrupted, including the BIOS and operating  
system (OS). If the BIOS or OS are damaged,  
the entire system can become unusable.  
Remember, the CP451-008 employs the Enhanced  
Write Filter (EWF) to protect the contents of the  
internal drive. Read the next section carefully  
before attempting to install, create, or edit any data  
files or applications on the CP451-008. If not  
executed properly, changes will be lost.  
7.3.1 INSTALLING LARGE FILES  
The best way to create and edit on the CP451-008  
is to use a USB drive plugged into the bottom of the  
unit and make changes directly to the USB drive  
then copy the final files to the CP451’s “C” drive.  
If the application or file is too large for the available  
RAM, the operation will be aborted. Use the disable  
batch file before installing the software. Make sure  
to reset the EWF when done.  
400-0518-001  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
7.4 AVSNAP  
TROUBLESHOOTING GUIDE  
8
AVSnap provides a complete environment for  
designing simple to sophisticated graphical user  
interfaces (GUIs). AVSnap is preinstalled on each  
CP451-008 making it easy to integrate into any  
control environment.  
We have carefully tested and found no problems in  
the supplied CP451-008; however, we would like to  
offer suggestions for the following:  
8.1 POWER IS NOT ON  
Cause 1: No AC power.  
Everything needed to start is included in a sample  
application. Use the predefined procedures and  
functions to communicate with devices over LAN or  
WLAN, or create your own custom functions. In  
addition to standard communication and control,  
the functions below are useful for typical touch  
screen applications and can be assigned to buttons  
or placed in startup and shutdown routines. The  
samples shown here require an application object  
named “App” to be part of the application.  
Solution: Verify the adapter is plugged into a  
working AC outlet and that the outlet  
has power. Use only the AC adapter  
shipped with the unit.  
Cause 2: Adapter is not plugged into  
CP451-008.  
Solution: Verify the DC power plug coming  
from the AC adapter is plugged all  
the way into the CP451-008.  
App.Shutdown................ Close the application and  
turn off the computer.  
Cause 3: The CP450 has a problem.  
Solution: If there is AC power to the adapter  
and the LED still does not turn on,  
the CP451-008 or the power adapter  
may require service, call ALTINEX  
at (714) 990-2300.  
App.SleepMonitor........... Turn off monitor power.  
App.Quit ......................... Quit  
the  
runtime  
environment and return to  
edit mode if running an  
AMT file. If running an  
EXE file, quit the EXE  
and close the application.  
8.2 SOFTWARE/FILES ARE MISSING  
Cause 1: Changes were not committed to  
memory.  
App.Stop ........................ Stop  
the  
executable  
application.  
Use with EXE files only!!!  
Solution: Make changes to the CP451-008  
then run the COMMIT batch file on  
the desktop before shutting down or  
restarting the CP451-008.  
App.Powersave .............. Hibernate (standby) the  
computer per display  
property settings.  
Cause 2: File/application was open when  
COMMIT was executed.  
App.RunScreensaver ..... Launch the screensaver.  
If no screensaver is  
Solution: Any files that are open for editing  
must be closed before executing the  
COMMIT batch file. For best results,  
close all applications and files before  
running the COMMIT batch file.  
installed this command  
has no effect.  
400-0518-001  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIAL APPLICATION  
ALTINEX POLICIES  
9
9.1 LIMITED WARRANTY/RETURN POLICIES  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
592 Apollo Street  
Brea, CA 92821 USA  
TEL: 714 990-2300  
TOLL FREE: 1-800-ALTINEX  
400-0518-001  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Aastra Telecom IP Phone SIP9133i User Manual
AEG Dishwasher 4270 I User Manual
Alloy Computer Products Network Card WDS2454AP User Manual
Altinex Network Card PNP400 User Manual
Altinex Stereo Amplifier DA1506RT User Manual
American Standard Plumbing Product 2097012 User Manual
Audiovox Car Satellite Radio System JSIR900H User Manual
Audiovox Stereo Amplifier BTR120 User Manual
Barco Crib Toy RS976986 08 User Manual
Eureka Tents Tent Nergy 1210 User Manual