DESIGNER SOLUTIONS  
1.3 CLEANING  
PRECAUTIONS / SAFETY WARNINGS  
1
·
·
Unplug the PNP400 before cleaning.  
Please read this manual carefully before using your  
PNP400 and keep it handy for future reference.  
These safety instructions are to ensure the long life  
of your PNP400 and to prevent fire and shock  
hazards. Please read them carefully and heed all  
warnings.  
Clean only with a dry cloth. Never use strong  
detergents or solvents such as alcohol or  
thinner. Do not use a wet cloth or water to clean  
the unit. Do not open the unit to clean.  
1.4 FCC NOTICE  
1.1 GENERAL  
·
This device complies with Part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
interference that may cause undesired  
operation.  
·
There are no user serviceable parts inside.  
Qualified ALTINEX service personnel must  
perform all service on the PNP400.  
1.2 HANDLING  
·
For best results, place the PNP400 on a flat,  
leveled surface in a dry area away from dust and  
moisture.  
·
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant to Part 15 of the FCC Rules.  
These limits are designed to provide reasonable  
protection against harmful interference when the  
·
To prevent fire or shock, do not expose this unit  
to water or moisture. Do not place the PNP400  
in direct sunlight, near heaters, or heat-radiating  
appliances, or near any liquid. Exposure to direct  
sunlight, smoke, or steam can harm internal  
components.  
equipment is operated in  
a
commercial  
environment. This equipment generates, uses,  
and can radiate radio frequency energy and if  
not installed and used in accordance with  
instructions found herein, may cause harmful  
interference to radio communications. Operation  
of this equipment in a residential area is likely to  
cause harmful interference in which case the  
user will be required to correct the interference  
at his own expense.  
·
·
·
·
·
·
·
Handle the PNP400 carefully. Dropping or  
jarring can damage the unit.  
Do not pull any cables that are attached to the  
PNP400.  
Do not place heavy objects on top of the  
PNP400.  
·
Any changes or modifications to the unit not  
expressly approved by ALTINEX, Inc. could void  
the user’s authority to operate the equipment.  
Do not use excessive force to push down on the  
top of the unit.  
Be careful. Serious injury could result because  
of the sharp edges inside of the PNP400.  
To turn off main power, disconnect the power  
cord powering the PNP400 outlets.  
We recommend using wall outlets with a Ground  
Fault Circuit Interrupter (GFCI) for maximum  
protection.  
400-0109-006  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
ABOUT YOUR PNP400  
2
TECHNICAL SPECIFICATIONS  
3
Specifications are subject to change.  
See www.altinex.com for up-to-date information.  
PNP400  
POP 'N PLUG TOWER  
MECHANICAL  
PNP400 (standard)  
4.00 in (102 mm)  
0.25 in (6 mm)  
2.909 in (74 mm)  
5.760 in (146 mm)  
6.674 in (170 mm)  
4.840 in (123 mm)  
Black  
The PNP400 Interconnect Tabletop Solution is  
designed for installation into a conference room  
table. The PNP400 provides a means of connecting  
audiovisual, network, and power sources into a  
presentation system. It is ideal for use with  
ALTINEX computer video interfaces like the  
VA6804FC. The PNP400 can “pop up” into a raised  
position to provide access to connectors, or it can  
be lowered into a table when not in use. The  
PNP400 uses a tower-type construction with a gas  
spring to raise the interface into position above the  
tabletop.  
Maximum Table Thickness  
Minimum Table Thickness  
Height Above Table (open)  
Height Below Table Surface  
Base Width  
Base Depth  
Finish  
The PNP400 Interconnect has two openings on  
either side of the unit, servicing both sides of a  
table. Several optional sectional plates are  
available for the following: AC power, computer  
video (15-pin HD), composite video (RCA), audio  
T° Operating  
10°C-35°C  
T° Maximum  
50°C  
Humidity  
90% non-condensing  
(RCA),  
computer  
audio  
(3.5 mm stereo),  
phone/modem (RJ-11), RS-232 (9-pin D-sub),  
network (RJ-45), etc. Contact the ALTINEX Sales  
Department for additional information regarding  
optional connectors.  
Table 1. PNP400 Mechanical  
The PNP400 Interconnect is designed for use with  
tables ranging from 0.25-4.0 in (6-102 mm) thick.  
The PNP400 comes in a standard matte black  
finish. Custom finishes for the top of the PNP400  
allow the unit to accent any tabletop and are  
available on a custom order basis for an additional  
charge.  
400-0109-006  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
PRODUCT DESCRIPTION  
4
POP-UP LID  
MOUNTING HOLES  
FOR ACCESSORY PLATES  
(front and back)  
GAS SPRING  
BEZEL  
TABLETOP  
THUMB SCREW  
MOUNTING  
BRACKET  
CHASSIS  
400-0109-006  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
APPLICATION DIAGRAMS  
DIAGRAM 1: TYPICAL SETUP  
5
400-0109-006  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 2: CUTOUT  
400-0109-006  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 3: TOP VIEW  
6.530"  
[166mm]  
7.860"  
[200mm]  
400-0109-006  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 4: FRONT VIEW  
2.909"  
[74 mm]  
5.760"  
[146 mm]  
6.674"  
[170 mm]  
400-0109-006  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 5: SIDE VIEW  
2.909"  
[74 mm]  
5.760"  
[146 mm]  
4.840"  
[123 mm]  
400-0109-006  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 6: MOUNTING  
2 MOUNTING BRACKETS  
MOUNTING BRACKETS DETAILS  
TOP VIEW  
SIDE VIEW  
2 THUMB SCREWS  
SIDE VIEW  
TABLETOP  
Install the mounting  
brackets into the grooves  
on both sides of the unit  
using the grooves that  
best fit the thickness of  
the tabletop.  
Thread the thumb screws  
through the mounting  
brackets as shown until  
the PNP400 is securely  
mounted to the tabletop.  
FRONT VIEW  
400-0109-006  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 7: ACCESSORY INSTALLATION  
ALIGN MOUNTING  
HOLES  
FEED CABLES  
THROUGH FRONT  
AND DOWN  
THROUGH CHASSIS  
(SP3201AV shown here.)  
PLASTIC RIVETS  
Insert this side  
through holes  
until it sits flush  
with the metal.  
Insert this side  
all the way  
down until it  
sits flush with  
dome surface.  
FASTEN WITH  
PLASTIC RIVETS  
BEFORE  
AFTER  
Feed any cables attached to the sectional plate through the front of the PNP400, then  
down through the opening in the bottom of the chassis. Make sure the cables exit the  
chassis on the same side as the plate. They should NOT cross over the center of the unit.  
1
Align the mounting holes of the sectional plate and PNP400 chassis.  
2
3
Use the plastic rivets supplied with the sectional plate to fasten the sectional plate to the  
chassis. A rivet tool is supplied with the PNP400.  
The plastic rivets may be removed by pressing  
the center pin all the way through the material  
using a small screwdriver. Then use small pliers  
to remove the plastic, being careful not to scratch  
the metal.  
NOTE:  
400-0109-006  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
DIAGRAM 8: CABLES/ACCESSORIES  
Model No.  
CUTOUT COVERS  
CVR1001  
Description  
Cover for PNP/TNP cutouts  
SECTIONAL PLATES  
Dual AC Power Outlet for United States &  
Canada with 2 slots and 12 ft (4 m) metal  
conduit  
SP2107US  
AC Power Outlet for United Kingdom,  
Singapore & Hong Kong  
SP2201UK  
SP2301CE  
SP2401AU  
SP3102EP  
SP3103EP  
SP3201AV  
AC Power Outlet for Continental Europe  
AC Power Outlet for Australia &  
New Zealand  
Dual, Empty Snap-in Ports with 1 slot  
Dual, Empty Ortronics CAT-6 Snap-in Ports  
with 1 slot  
15-pin HD-Female to Male + 3.5 mm  
Stereo Female to Male  
15-pin HD-Female to Female Gender  
Changer + 3.5 mm Stereo Female to  
Terminal Block  
4-pin Mini DIN + RCA Female 3.5 mm  
Stereo with 1 slot (universal plate for  
PNP400)  
SP3202AV  
SP3204AV  
REPLACEMENT PARTS  
AC401-303  
Gas Spring for PNP400 Series  
400-0109-006  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
Step 7. Secure the power cord using the cable  
clamp provided. Pass the power cord  
(if any) from the bottom of the housing  
and attach it to the table leaving a service  
loop beneath the unit. Before tightening  
the clamp, open and close the unit from  
the top several times. Set the service loop  
for smooth operation only. Do NOT leave  
excessive cable hanging below the table.  
INSTALLING YOUR PNP400  
Step 1. Refer to the ALTINEX  
6
website,  
www.altinex.com, to download the latest  
templates and instructions for tabletop  
cutting requirements and installation.  
In order to do this, locate the PNP400 on  
the website and go to its detail page. The  
links to the templates, user’s guide, and  
more are on the left-hand side of the  
screen.  
NOTE: The table can be 0.25-4.0 in  
(6-102 mm) thick.  
Step 2. Print all information applicable to the  
installation of the PNP400, including the  
templates and any detailed installation  
instructions.  
Step 3. Mark the table’s surface to indicate the  
correct positioning of the unit. The face of  
the unit is typically parallel to the longest  
sides of the tables.  
Step 4. Cut an opening into the table’s surface.  
This operation should be performed by  
experienced professionals in order to  
insure accuracy and to be aesthetically  
pleasing.  
Step 8. Secure other cables from the PNP400 to  
the table separate from the power cord.  
All cables should be secured using a  
service loop to allow the unit to open and  
close easily.  
NOTE: Always confirm dimensions before  
cutting to insure that specifications have  
not changed.  
Step 9. Once you have connected power and the  
proper cables to the unit, you may raise  
the unit. To raise the PNP400 into  
position, press the top of the unit.  
Step 5. Lower the PNP400 into the opening in the  
table and make sure the bezel of the unit  
sits evenly in the table.  
Step 10. To lower the PNP400, push on the top of  
the unit until it locks into place. Do NOT  
use excessive force to press down on the  
pop-up.  
Step 6. From under the table, insert the mounting  
brackets into the slots on the side of the  
unit. See DIAGRAM 6 on page 10 for  
details. Place the brackets at the desired  
height for the table thickness and secure  
them to the bottom of the table using the  
thumb screws provided. There are two  
support brackets, one for each side of the  
unit.  
400-0109-006  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DESIGNER SOLUTIONS  
OPERATION  
7
ALTINEX POLICIES  
9
7.1 INSTALL SECTIONAL PLATES  
9.1 LIMITED WARRANTY/RETURN POLICIES  
Install sectional plates in the empty slots on each  
side of the PNP400 until the plates snap into place.  
Secure the plates using the plastic, removable  
rivets as shown in DIAGRAM 7.  
Please see the ALTINEX website at  
www.altinex.com for details on warranty and  
return policies.  
9.2 CONTACT INFORMATION  
ALTINEX, Inc.  
TROUBLESHOOTING GUIDE  
8
592 Apollo Street  
We have carefully tested and found no problems in  
the supplied PNP400; however, we would like to  
offer suggestions for the following:  
Brea, CA 92821 USA  
TEL: 714 990-2300  
·
Please make sure that the highest quality video,  
audio, network, and telephone cables or  
connectors are used.  
TOLL FREE: 1-800-ALTINEX  
·
If there has been damage, then do not use the  
PNP400 unit. Immediately contact the ALTINEX  
Sales Department to have the unit repaired.  
400-0109-006  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3M Oxygen Equipment 7048 User Manual
AB Soft Network Router TDW 33 User Manual
Acer Computer Monitor PD725P User Manual
Acer Server G300 Series User Manual
Acer Server R310 User Manual
Acer Tent AC701 User Manual
Aiphone Intercom System JF 1FD User Manual
Airlink101 Network Card AWLH4030 User Manual
American Standard Indoor Furnishings 0410021 User Manual
BK Stereo Amplifier ST3030 Series II User Manual