Icom Network Router IC FR5100 User Manual

INSTRUCTION MANUAL  
VHF FM REPEATER  
iFR5100  
UHF FM REPEATER  
iFR6100  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FORWARD  
SUPPLIED ACCESSORIES  
Thank you for purchasing this Icom repeater. The  
IC-FR5100/IC-FR6100 vhf/uhf fm repeaters is de-  
signed and built with Icom’s state of the art technol-  
ogy and craftsmanship. With proper care, this product  
should provide you with years of trouble-free opera-  
tion.  
The following accessories are supplied.  
Handles  
For handles attachment  
Spacers  
Screws  
We want to take a couple of moments of your time to  
thank you for making the IC-FR5100/IC-FR6100 your re-  
peater of choice, and hope you agree with Icom’s philos-  
ophy of “technology first.Many hours of research and  
development went into the design of your IC-FR5100/  
IC-FR6100.  
Function name stickers*  
DC power cable  
KEY SEAL  
D FEATURES  
m Up to 2 channels operation  
* Used for labelling the programmable function  
keys according to their assinged functions.  
You can install a channel extension module (op-  
tional UR-FR5100/UR-FR6100) into a repeater. 2  
channels can be operated as the repeater when a  
channel extension module is installed.  
m Built-in 5-Tone, DTMF encoder & decoder  
Multiple signaling systems are equipped as stan-  
dard. These systems are fully compatible with  
Icom F-series radios.  
TABLE OF CONTENTS  
m DTMF remote control capability  
You can control the repeater from a remote loca-  
tion over the air or over a phone line with DTMF.  
m D-Sub 25 pin ACC port equipped  
You can use the optional equipment via the D-sub  
25 pin ACC port equipped on the repeater’s rear  
panel.  
m Other features  
- Wide frequency coverage  
(136 to 174 MHz, 400 to 470 MHz)  
- PC programmable  
- 19 inch rack mount  
- Optional Voice Scrambler Unit (UT-109R/  
UT-110R) for base operating mode  
VOICE CODING TECHNOLOGY  
The AMBE+2™ voice coding Technology embodied in this  
product is protected by intellectual property rights including  
patent rights, copyrights and trade secrets of Digital Voice  
Systems, Inc. This voice coding Technology is licensed  
solely for use within this Communications Equipment. The  
user of this Technology is explicitly prohibited from attempt-  
ing to extract, remove, decompile, reverse engineer, or  
disassemble the Object Code, or in any other way convert  
the Object Code into a human-readable form. U.S. Patent  
Nos. #5,870,405, #5,826,222, #5,754,974, #5,701,390,  
#5,715,365, #5,649,050, #5,630,011, #5,581,656,  
#5,517,511, #5,491,772, #5,247,579, #5,226,084 and  
#5,195,166.  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PANEL DESCRIPTION  
1
n Front panel  
r
t
y
Function  
display  
q
w
e
P
0
P
1
P
2
P
3
P
4
o
i
u
q INTERNAL SPEAKER  
u
MICROPHONE CONNECTOR [MIC]  
This 8-pin modular jack accepts the optional micro-  
Monitors received signals.  
phone.  
w VOLUME CONTROL [VOLUME] (p. 7)  
KEEP the [MIC] connector cover attached to the  
repeater when the optional microphone is not  
used.  
Adjusts the audio output level.  
e SELECTOR DIAL [SELECT]  
Rotate to adjust the squelch threshold level, select  
the operating channel. (Depending on the pre-  
programmed condition.)  
q +8 V DC output (Max. 15 mA)  
w Output port for PC programming  
e NC  
q
i
r M PTT (Input port for TX control)  
t Microphone ground  
y Microphone input  
u Ground  
r POWER INDICATOR [POWER]  
Lights green at ‘A’ module's indicator while the  
repeater power is turned ON.  
i Input port for PC programming  
When a channel extension module is installed:  
Lights green at the selected module indicator  
(‘A’ or ‘B’) while the repeater power is turned  
ON.  
Lights orange at the un-selected module indica-  
tor (‘A’ or ‘B’) while the repeater power is turned  
ON.  
i POWER SWITCH [POWER]  
Push to turn the repeater power ON.  
Push and hold for 3 sec. to turn the repeater  
power OFF.  
When a channel extension module is installed:  
While the repeater power is turned ON, push  
to select the desired module to operate the re-  
peater as the base station.  
t TRANSMIT INDICATOR [TX]  
Lights red while transmitting.  
• The power indicator of the selected module unit  
lights green.  
y BUSY INDICATOR [BUSY]  
Lights green while receiving a signal or when the  
noise squelch is open.  
o DEALER-PROGRAMMABLE KEYS  
Desired functions can be programmed indepen-  
dently by your dealer.  
About [PWR], [TX] and [BUSY] indicators:  
‘A’ and ‘B’ modules indicators are available for  
these indications. ‘A’ module's indicator correspond  
to the original module, and ‘B’ module's indicator  
correspond to an extended module.  
Ask your dealer for details.  
• Because these keys are programmable, the functions  
of these keys are unique to each unit.  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
PANEL DESCRIPTION  
D Function display  
q
w
e
r
t
ICOM Inc.  
y
q SIGNAL STRENGTH INDICATOR  
r COMPANDER INDICATOR  
Indicates relative signal strength level.  
Appears when the compander function is activated.  
1
w LOW POWER INDICATOR  
t SCRAMBLER/ENCRYPTION INDICATOR  
Appears when the voice scrambler/encryption  
function is activated.  
Appears when low output power is selected.  
2
e AUDIBLE INDICATOR  
3
y ALPHANUMERIC DISPLAY  
Appears when the channel is in the ‘audible’ (un-  
mute) condition.  
Shows a variety of text or code information.  
4
5
n Rear panel  
6
q
w
e
r
t
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
The optional channel extention module can be installed.  
Ask your dealer for details.  
q
EXTERNAL SPEAKER CONNECTOR [SP]  
r DC POWER RECEPTACLE  
Connect the optional SP-22.  
Connects the supplied DC power cable from this  
connector to an external 13.2 V DC power supply.  
w RECEIVE ANTENNA CONNECTOR [RX]  
Connects a receive antenna (impedance: 50 ˘)  
and inputs receiving signals.  
t TRANSMIT ANTENNA CONNECTOR [TX]  
Connects a transmit antenna (impedance: 50 ˘)  
and outputs transmit signals.  
e ACCESSORY CONNECTOR [ACC]  
Connects to the accessory connector.  
• See pgs. 3 for accessory connector information.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
1
PANEL DESCRIPTION  
D Accessory connector  
!
@
q
!
Pin No. Pin Name  
Description  
Specification  
1
2
3
4
5
6
7
8
NC  
TXD  
No connection  
Output terminal for serial communication data.  
Input terminal for serial communication data.  
Output terminal for request-to-send data.  
Input terminal for clear-to-send data.  
No connection  
RXD  
RTS  
CTS  
NC  
GND  
MOD IN  
Serial/digital signal ground  
Modulator input from an external terminal unit.  
Input level: 300 mV rms  
Output terminal for AF signals from the AF detector circuit.  
Output level is fixed, regardless of [AF] control.  
The desired function can be assigned.*  
(Default: Null)  
9
DISC OUT  
EXT. D/A  
Output level: 300 mV rms  
10  
11  
12  
13  
14  
VCC  
EXT. A/D  
NC  
13.2 V DC output  
Output current: Less than 1 A  
Customize A/D input (Not used)  
No connection  
GND  
Ground  
The desired function can be assigned.*  
(Default: Null)  
15  
16  
17  
18  
19  
EXT.I/O 15  
EXT.I/O 16  
EXT.I/O 17  
EXT.I/O 18  
EXT.I/O 19  
+5 V pull up, Active=L  
+5 V pull up, Active=L  
+5 V pull up, Active=L  
+5 V pull up, Active=L  
+5 V pull up, Active=L  
The desired function can be assigned.*  
(Default: P0 Monitor Output)  
The desired function can be assigned.*  
(Default: Busy Output)  
The desired function can be assigned.*  
(Default: Null)  
The desired function can be assigned.*  
(Default: EPTT Input)  
20  
21  
DATA IN  
Input terminal for data.  
The desired function can be assigned.*  
(Default: Analog Audible Output)  
The AF detector Output.  
EXT.I/O 21  
+5 V pull up, Active=L  
22  
23  
AF OUT  
The desired function can be assigned.*  
(Default: Mic Mute Output)  
EXT.I/O 23  
+5 V pull up, Active=L  
The desired function can be assigned.*  
(Default: Null)  
24  
25  
EXT.I/O 24  
EXT.I/O 25  
+5 V pull up, Active=L  
+5 V pull up, Active=L  
The desired function can be assigned.*  
(Default: Mic Hanger Output)  
* The desired function can be assigned using the optional CS-FR5000 cloning software. Ask your dealer for details.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
INSTALLATION AND CONNECTIONS  
2
n Unpacking  
n Antenna connection  
After unpacking, immediately report any damage to  
the delivering carrier or dealer. Keep the shipping car-  
tons.  
For radio communications, the antenna is a critical  
component, along with output power and sensitivity.  
Select antenna(s), such as a well-matched 50 ˘ an-  
tenna, and feedline. 1.5:1 or better of Voltage Stand-  
ing Wave Ratio (VSWR) is recommended for desired  
band. Of course, the transmission line should be a  
coaxial cable.  
For a description and a diagram of accessory equip-  
ment included with the repeater, see ‘SUPPLIED AC-  
CESSORIES’ on p. ii of this manual.  
CAUTION: Protect repeater from lightning by using  
a lightning arrestor.  
n Selecting a location  
NOTE: There are many publications that describe  
proper antennas and their installation. Check with  
your local dealer for more information and recom-  
mendations.  
Select a location for the repeater that allows adequate  
air circulation, free from extreme heat, cold, or vibra-  
tions, and away from TV sets, TV antenna elements,  
radios and other electromagnetic sources.  
1
2
3
TYPE-N CONNECTOR INSTALLATION EXAMPLE  
4
Nut Rubber gasket  
q
15 mm  
Slide the nut, flat washer, rubber gasket and clamp over the coaxial  
cable, then cut the end of the cable evenly.  
5
6
Washer  
Clamp  
Center  
conductor  
w
Strip the cable and fold the braid back over the clamp.  
7
8
3 mm  
6 mm  
e
r
Solder hole  
9
Soft solder the center conductor. Install the center conductor pin and  
solder it.  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
No space  
Carefully slide the plug body into place aligning the center conductor  
pin on the cable. Tighten the nut onto the plug body.  
Be sure the center conductor is  
the same height as the plug body.  
15 mm (1932 in) 6 mm (14 in) 3 mm (18 in)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
INSTALLATION AND CONNECTIONS  
n Front panel connection  
P0  
P1  
P2  
P3  
P4  
HM-152 HAND  
MICROPHONE  
(optional)  
SM-25 DESKTOP  
MICROPHONE CONNECTOR (Front panel view)  
MICROPHONE  
q +8 V DC output (Max. 10 mA)  
w Output port for PC programming  
(optional)  
q
i
e NC  
r M PTT (Input port for TX control)  
t Microphone ground  
y Microphone input  
u Ground  
i Input port for PC programming  
CAUTION: DO NOT short pin 1 to ground as this can  
damage the internal 8 V regulator. DC voltage is applied  
to pin 1 for microphone operation. Only Icom micro-  
phones are recommended.  
n Rear panel connection  
SP-22 EXTERNAL SPEAKER  
ACC CONNECTOR (p. 3)  
Used for external equipment control.  
Connect a 4 ˘ external speaker.  
[TX ANT] (p. 4)  
[RX ANT] (p. 4)  
20 A  
fuses  
R CAUTION! NEVER remove  
the fuse-holder from the DC  
DC power supply  
AC outlet  
power receptacle.  
13.2 V; at least 20 A  
Red Black  
+
_
R When you disconnect the  
DC power cable, take care  
no crack of your fingernail.  
AC cable  
w
Supplied  
DC power cable  
Red  
Black  
q Push  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2
INSTALLATION AND CONNECTIONS  
n Power supply connection  
n Mounting the repeater  
Make sure the repeater’s power is turned OFF when  
connecting a DC power cable.  
D Using the supplied handle  
The supplied handles are available for mounting the  
repeater into a 19 inch rack. The handles can be in-  
stalled to the repeater’s front panel.  
CAUTION: Voltages greater than 16 V DC will dam-  
age the repeater. Check the source voltage before  
connecting the power cable.  
q Attach the supplied handles to both sides of the re-  
peater’s front panel with the spacers, then tighten  
the screws as below.  
1
P
0
P
1
P
2
P
3
P
4
2
Screw  
Handle  
3
Spacer  
4
wThe completed installation should look like as  
below.  
5
6
P
0
P
1
P
2
P
3
P
4
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
OPERATION  
3
n Receiving and transmitting  
D Base station operation  
D Repeater operation  
Ask your dealer for details of the repeater’s program-  
ming.  
Receiving  
q Push [POWER] to turn the power ON.  
w Set the audio and squelch levels.  
Rotate [SELECT]*1 fully counterclockwise in ad-  
vance.  
When the power is turned ON, the [PWR] indicator  
lights green. (p. 1)  
Rotate [VOLUME] to adjust the audio output  
level.  
The [TX] and [BUSY] indicators light simultane-  
ously while transmitting/receiving a signal.  
• The [TX] indicator lights red.  
Rotate [SELECT]*1 clockwise until the noise  
disappears.  
• The [BUSY] indicator lights green.  
e Push [CH Up]*2 or [CH Down]*2 to select the de-  
sired channel.  
NOTE: A power amplifier protector is built-in to the  
repeater. The protector is activated when the re-  
peater temperature becomes extremely high due  
to the frequently access to the repeater to reduce  
the transmit output power level. The output power  
will return to the normal level when the repeater  
has cooled down.  
• When receiving a signal, the [BUSY] indicator lights  
green and audio is emitted from the speaker.  
• Further adjustment of [VOLUME] to a comfortable lis-  
tening level may be necessary at this point.  
*1 When the [SQL Level Up/Down] key function is assigned  
to [SELECT].  
*2 When the [CH Up]/[CH Down] key functions are as-  
signed.  
Transmitting  
q Take the microphone off hook.  
w Wait for the channel to become clear.  
e Push and hold [PTT] to transmit, then speak into  
the microphone at your normal voice level.  
r Release [PTT] to receive.  
IMPORTANT:  
To maximize the audio quality of the transmitted sig-  
nal:  
(1) Pause briefly after pushing [PTT].  
(2) Hold the microphone 1 to 2 inch (2.5 to 5 cm) from  
your mouth, then speak into the microphone at a  
normal voice level.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
MAINTENANCE  
4
n Troubleshooting  
If you are unable to locate the cause of a problem or  
solve it through the use of this chart, contact the near-  
est Icom Dealer or Service Center.  
The following chart is designed to help correct prob-  
lems which are not equipment malfunctions.  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
REF.  
Power does not come • DC power cable is improperly connected. • Re-connect the DC power cable correctly.  
on when [POWER] is  
pgs.  
5, 6  
pushed.  
• Fuse is blown.  
• Check the cause, then replace the fuse with p. 8  
a spare one.  
No sounds from the • Volume level is too low.  
speaker.  
• Rotate [VOLUME] clockwise to obtain a p. 7  
suitable listening level.  
• While in base operating mode, rotate [SE- p. 7  
LECT] to counterclockwise to open the  
squelch. (When the [SQL Level Up/Down]  
key function is assigned to [SELECT].)  
1
• The squelch is closed.  
2
• The audio mute function is activated.  
• Push [MONI] (if assigned) to the audio  
mute function OFF.  
3
• A selective call or squelch function is acti- Turn the appropriate function OFF.  
vated such as 5 tone call or tone squelch.  
4
• The front speaker is set to OFF.  
• Turn the front speaker ON using the op-  
tional CS-FR5000 cloning software. Ask  
your dealer for details.  
5
6
Sensitivity is low and • Antenna feedline or the antenna connector • Check and re-connect (or replace if neces- p. 5  
only strong signals are has a poor contact or is short-circuited.  
audible.  
7
sary), the antenna feedline or antenna con-  
nector.  
8
Received signal cannot • Optional voice scrambler is turned OFF.  
Turn the optional voice scrambler ON.  
• Reset the scrambler code.  
be understood.  
• Scrambler code is not set correctly.  
9
Output power is too low. • Output power is set to Low.  
• Push [HIGH/LOW] (if assigned) to select  
the High power.  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
• Power amplifier protection circuit is acti- • Cool down the repeater or stop accessing  
vated.  
to the repeater until it has cooled down.  
No contact possible with • The other station is using tone squelch.  
Turn the tone squelch function ON.  
another station.  
• While in base operating mode, the re- • Set the repeater to simplex, when other  
peater is set to duplex. transceiver is set to simplex.  
n Fuse replacement  
If a fuse blows or the repeater stops functioning, try to  
find the source of the problem, and then replace the  
damaged fuse with a new, rated fuse.  
CAUTION: DISCONNECT the DC power cable  
from the repeater. Otherwise, there is danger of  
electric shock and/or equipment damage.  
D Line fuse replacement  
Fuse rating: 20 A  
USE the 20 A fuse only.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
OPTIONS  
5
• SP-22 external speaker  
Compact and easy-to-install.  
Input impedance : 4 ˘  
Max. input power : 5 W  
• HM-152 hand microphone  
• SM-25 desktop microphone  
UR-FR5100/UR-FR6100 channel extension modules  
• UT-109R voice scrambler unit  
Non-rolling type (max. 32 codes).  
• UT-110R voice scrambler unit  
Rolling type (max. 1020 codes).  
* The scrambler systems of the UT-109R and UT-  
110R are not compatible with each other.  
Some options may not available in some countries.  
Please ask your dealer for details.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ABOUT CE  
6
INSTALLATION NOTES  
• Compliance of base station transmitter installa-  
tions with EN50385  
• Installation with a vertical type antenna at VHF-  
UHF  
The installation of this equipment and it’s associated  
antenna should be made in such a manner as to re-  
spect the EC recommended electromagnetic (EM)  
field exposure limits. (1999/519/EC)  
You need to consider the distances between the an-  
tenna and any point where persons may have access.  
Allowing an average height of 1.8 m for a person in  
the vicinity of the antenna the clearance distances  
can be evaluated as follows. For the antenna a for-  
ward gain of 1.6 and downward gain of unity has been  
assumed.  
In order not to exceed these exposure limits it is nec-  
essary to determine the ‘Compliance Boundary,’ that  
means the volume within which the EM field radiated  
by the transmitter/antenna installation may exceed the  
1999/519/EC limits. You will then need to ensure that  
members of the general public do not have access  
within this area. The actual Compliance Boundary for  
this repeater will be totally dependant on the antenna,  
feeder, RF amplifier and other passive or active de-  
vices used in the installation.  
Height  
clearance clearance  
Front  
Power  
EIRP Distance  
1.6 watts 0.32 m  
1
1 watt  
2.1 m  
2.8 m  
3.4 m  
5 m  
0.4 m  
1.3 m  
2 m  
2
10 watts  
25 watts  
16 watts  
40 watts  
1 m  
1.6 m  
3.2 m  
10 m  
3
100 watts 160 watts  
1 kW 1600 watts  
4 m  
12 m  
13 m  
4
The RF output power of this repeater is 25 watts.  
5
The figures contained in this guide are based on the  
recommended limits for the general public and are  
obtained by ‘worst case’ numerical analysis. For a de-  
finitive evaluation of any given installation, measure-  
ments should be made with an EM field meter and a  
broadband calibrated probe.  
• Installation with a yagi or directive type antenna  
Exposure distance assumes that the predominant ra-  
diation pattern is forwards and that radiation vertically  
downwards is at unity gain (sidelobe suppression is  
equal to main lobe gain). This is true of almost every  
gain antenna today. Exposed persons are assumed  
to be beneath the antenna array and have a typical  
height of 1.8 m.  
6
7
8
• Installation  
9
The antenna should be installed as high as possible  
for maximum efficiency and minimum EM field at  
ground-level. The evaluation of radiated field should  
take into account any additional RF amplifiers used,  
any loss in the antenna feeder cable and the gain of  
the antenna used as well as its polar radiation pattern.  
The figures assume the worst case emission of con-  
stant carrier.  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
RF power Clearance heights by frequency band  
13 cm  
and above  
Watts  
10–2 m  
70 cm  
23 cm  
If there are any objects or structures larger than  
half a wavelength close to the antenna, or within the  
clearance distances specified, then these can cause  
reflections which will have an effect on the overall ra-  
diation pattern.  
1
10  
25  
2.1 m  
2.8 m  
3.4 m  
5 m  
2 m  
2.7 m  
3.3 m  
4.7 m  
2 m  
2.5 m  
2.7 m  
3.6 m  
7.3 m  
2 m  
2.3 m  
2.5 m  
3.2 m  
6.3 m  
100  
1000  
12 m 11.5 m  
For any installation you need to consider ‘height clear-  
ance’ (i.e. the height above any place where persons  
may have access) and ‘front clearance’ (i.e. the dis-  
tance in front of the antenna where the radiated field  
may exceed the recommended limits). Normally with  
an antenna installed on a reasonably high mast or  
tower, there will not be any access point directly in  
front but care should be exercised when there are  
other buildings higher than the antenna within the vi-  
cinity.  
EIRP  
Forward clearance, EIRP by frequency band  
13 cm  
Watts  
10–2 m  
70 cm  
23 cm  
and above  
0.7 m  
3 m  
100  
1000  
10,000  
100,000  
2 m  
6.5 m  
20 m  
65 m  
2 m  
6 m  
18 m  
60 m  
1.1 m  
3.5 m  
11 m  
35 m  
7 m  
29 m  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
6
ABOUT CE  
• Typical installation example  
• Operating Notes  
A UHF base station transmitter is to be installed on  
the roof of an office.  
All of the above comments on RF safety assume that  
the radio is transmitting continuously in a constant  
carrier mode such as FM or RTTY etc.  
The transmit power is 25 watts, there is 20 m of  
RG-213 coaxial cable and the antenna is vertically  
polarised dipole.  
The RF exposure limits recommended by the EC are  
based on the mean power averaged over a 6 minute  
period.  
The specification of the RG-213 cable gives a loss  
of 1.5 dB/10 m. There will be 3 dB loss for the 20 m  
length used.  
Therefore if the total transmit time during any 6  
minute period is reduced, then the installation will be  
even further within the recommended limits.  
The RF power at the antenna input will be 12.5 watts.  
The dipole antenna has a forward gain of 0 dBd or  
1.6, giving an EIRP of 20 watts.  
CE Versions of the IC-FR5100/IC-FR6100  
which display the “CE” symbol on the serial  
number seal, comply with the essential re-  
quirements of the European Radio and  
Telecommunication Terminal Directive  
1999/5/EC.  
Referring to the table above for VHF/UHF vertical  
antennas, this gives a front clearance distance of ap-  
prox. 1.5 m and a height clearance of 3 m.  
The antenna installation needs to ensure that the low-  
est part of the antenna is at least 3 m above any point  
where the general public may gain access and that  
they cannot pass within 1.5 m in front of the antenna.  
This warning symbol indicates that this  
equipment operates in non-harmonised  
frequency bands and/or may be subject to  
licensing conditions in the country of use.  
Be sure to check that you have the correct  
version of this radio or the correct pro-  
gramming of this radio, to comply with na-  
tional licensing requirement.  
If there is no general public access to the roof in  
question then the antenna could be mounted on a  
short stub mast. If there is such access to the roof  
then the antenna could be mounted on top of a short  
mast of 3.2 m high. The mast position should be such  
that the antenna can radiate clearly i.e. no other ob-  
ject or structure is within 1.5 m (preferably more).  
• List of Country codes (ISO 3166-1)  
Country  
Austria  
Belgium  
Bulgaria  
Croatia  
Czech Republic  
Cyprus  
Denmark  
Estonia  
Codes  
Country  
Codes  
1
2
3
4
5
6
7
8
9
AT  
BE  
BG  
HR  
CZ  
CY  
DK  
EE  
FI  
FR  
DE  
GR  
HU  
IS  
18 Liechtenstein  
19 Lithuania  
20 Luxembourg  
21 Malta  
22 Netherlands  
23 Norway  
LI  
LT  
It should be relatively easy to fulfil all these recom-  
mendations.  
LU  
MT  
NL  
NO  
PL  
PT  
RO  
SK  
SI  
ES  
SE  
CH  
TR  
GB  
If for any reason such minimum distances are impos-  
sible to guarantee then some type of access con-  
trol fence or barrier around the antenna installation  
should be provided.  
24 Poland  
25 Portugal  
26 Romania  
27 Slovakia  
28 Slovenia  
29 Spain  
30 Sweden  
31 Switzerland  
32 Turkey  
Finland  
10 France  
11 Germany  
12 Greece  
13 Hungary  
14 Iceland  
15 Ireland  
16 Italy  
Should a Yagi type antenna be used then you will  
have to obtain a 3 dimensional polar plot of the radia-  
tion characteristic from the manufacturer and evaluate  
the clearance distances in both vertical and horizontal  
planes.  
IE  
IT  
33 United Kingdom  
17 Latvia  
LV  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
ABOUT CE  
DECLARATION  
OF CONFORMITY  
We Icom Inc. Japan  
1-1-32, Kamiminami, Hirano-ku  
Osaka 547-0003, Japan  
0168  
Declare on our sole responsibility that this equipment complies with the  
essential requirements of the Radio and Telecommunications Terminal  
Equipment Directive, 1999/5/EC, and that any applicable Essential Test  
Suite measurements have been performed.  
Düsseldorf 16th Apr.2008  
Place and date of issue  
Kind of equipment: VHF REPEATER  
1
Type-designation:  
iC-fr5100/ur-fr5100  
Authorized representative name  
136–174 MHz 6.25 kHz/12.5 kHz/25 kHz  
136–174 MHz 6.25 kHz/12.5 kHz/20 kHz  
2
Version (where applicable):  
Y. Furukawa  
General Manager  
3
This compliance is based on conformity with the following harmonised  
standards, specifications or documents:  
i)  
EN 301 489-1 v1.4.1 (August 2002)  
EN 301 489-5 v1.3.1 (August 2002)  
EN 300 086-2 v1.1.1 (March 2001)  
EN 301 166-2 v1.1.1 (December 2001)  
EN 300 219-2 v1.1.1 (March 2001)  
EN 300 113-2 v1.3.1 (December 2003)  
EN 60950-1: 2001  
4
ii)  
iii)  
iv)  
v)  
5
Signature  
vi)  
vii)  
viii)  
6
EN 50385: 2002  
7
8
DECLARATION  
OF CONFORMITY  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
We Icom Inc. Japan  
1-1-32, Kamiminami, Hirano-ku  
Osaka 547-0003, Japan  
0168  
Declare on our sole responsibility that this equipment complies with the  
essential requirements of the Radio and Telecommunications Terminal  
Equipment Directive, 1999/5/EC, and that any applicable Essential Test  
Suite measurements have been performed.  
Düsseldorf 25th Feb.2008  
Place and date of issue  
Kind of equipment: UHF REPEATER  
Type-designation:  
iC-fr6100/ur-fr6100  
Authorized representative name  
400–470 MHz 6.25 kHz/12.5 kHz/25 kHz  
400–470 MHz 6.25 kHz/12.5 kHz/20 kHz  
Version (where applicable):  
Y. Furukawa  
General Manager  
This compliance is based on conformity with the following harmonised  
standards, specifications or documents:  
i)  
EN 301 489-1 v1.4.1 (August 2002)  
EN 301 489-5 v1.3.1 (August 2002)  
EN 300 086-2 v1.1.1 (March 2001)  
EN 301 166-2 v1.1.1 (December 2001)  
EN 300 219-2 v1.1.1 (March 2001)  
EN 300 113-2 v1.3.1 (December 2003)  
EN 60950-1: 2001  
ii)  
iii)  
iv)  
v)  
Signature  
vi)  
vii)  
viii)  
EN 50385: 2002  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
< Intended Country of Use >  
AT BE CY CZ DK EE  
FI  
IT  
FR DE GR HU IE  
LV LT LU MT NL  
PL PT SK SI  
ES SE  
GB IS  
RO TR HR  
LI  
NO CH BG  
A-6636H-1EU-w  
Printed in Japan  
© 2008 Icom Inc.  
Printed on recycle paper with soy ink.  
1-1-32 Kamiminami, Hirano-ku, Osaka 547-0003, Japan  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Scuba Diving Equipment 312497G User Manual
Harbor Freight Tools Motorcycle Accessories 94813 User Manual
Harbor Freight Tools Paint Sprayer 02471 User Manual
Honeywell Carbon Monoxide Alarm C8600A User Manual
Hotpoint Dishwasher BCI450 User Manual
HP Hewlett Packard Personal Computer a6230 User Manual
Hunter Fan Ventilation Hood 82003 User Manual
Husky Switch HME 421E User Manual
Husqvarna Water Pump 966613502 User Manual
iHome Computer Keyboard iDM5 User Manual