$'(0&2ꢀ9,67$ꢁꢂꢃꢀ
ꢀꢁ3DUWLWLRQHGꢂ6HFXULW\ꢂ6\VWHPꢂ
ꢂ
ꢂ
,QVWDOODWLRQ DQG 6HWXS *XLGH
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
N7001V5 5/04 Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
.
Table of Contents
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
List of Figures...................................................................................................................................... v
Conventions Used in This Manual..................................................................................................... vi
SECTION 1: General Description.....................................................................................................1-1
About the VISTA-40 ...........................................................................................................................................................1-1
Features.............................................................................................................................................................................1-1
SECTION 2: Partitioning...................................................................................................................2-1
Theory of Partitioning.........................................................................................................................................................2-1
Setting-Up a Partitioned System ........................................................................................................................................2-1
SECTION 3: Installing the Control ...................................................................................................3-1
Mounting the Control Cabinet ............................................................................................................................................3-1
Installing the Cabinet Lock.................................................................................................................................................3-1
Grade A Mercantile Premises Listing Guidelines...............................................................................................................3-1
Grade A Mercantile Safe and Vault Listing Guidelines ......................................................................................................3-2
Installing the Control’s Circuit Board ..................................................................................................................................3-2
Installing the Keypads........................................................................................................................................................3-3
Installing External Sounders...............................................................................................................................................3-4
Telephone Line Connections .............................................................................................................................................3-5
Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9 ...................................................................................3-6
Installing RPM Devices ....................................................................................................................................................3-10
Wireless Zone Expansion.................................................................................................................................................3-13
Installing Relay Devices ...................................................................................................................................................3-16
Installing the Ground Start Module...................................................................................................................................3-17
Installing a Remote Keyswitch .........................................................................................................................................3-18
Remote Keypad Sounder.................................................................................................................................................3-19
Long Range Radio Connected to the J7 Triggers............................................................................................................3-19
Installing a 4100SM..........................................................................................................................................................3-19
Installing the 4285/4286 VIP Module ...............................................................................................................................3-20
Installing the Audio Alarm Verification Module.................................................................................................................3-22
Connecting the Transformer.............................................................................................................................................3-23
Panel Earth Ground Connections.....................................................................................................................................3-25
Determining the Control’s Power Supply Load.................................................................................................................3-25
Determining the Size of the Standby Battery ...................................................................................................................3-26
SECTION 4: Programming................................................................................................................4-1
Program Modes..................................................................................................................................................................4-1
Entering and Exiting Programming Mode...........................................................................................................................4-1
Data Field Programming Mode ..........................................................................................................................................4-1
#93 Menu Mode Programming...........................................................................................................................................4-2
Zone Number Designations................................................................................................................................................4-4
Zone Response Type Definitions .......................................................................................................................................4-5
Zone Input Type Definitions ...............................................................................................................................................4-6
Programming for 4100SM ..................................................................................................................................................4-7
Programming for Access Control........................................................................................................................................4-7
SECTION 5: Data Field Descriptions ...............................................................................................5-1
About Data Field Programming..........................................................................................................................................5-1
Programming Data Fields...................................................................................................................................................5-1
SECTION 6: Downloading Primer ....................................................................................................6-1
General Information ...........................................................................................................................................................6-1
Getting On-Line with a Control Panel.................................................................................................................................6-2
Direct-Wire Downloading....................................................................................................................................................6-3
Telco Handoff.....................................................................................................................................................................6-3
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
SECTION 7: Setting the Real-Time Clock........................................................................................7-1
General Information ...........................................................................................................................................................7-1
Setting the Time and Date .................................................................................................................................................7-1
SECTION 8: User Access Codes......................................................................................................8-1
General Information ...........................................................................................................................................................8-1
User Codes & Levels of Authority ......................................................................................................................................8-1
Multiple Partition Access ....................................................................................................................................................8-2
Adding a Master, Manager, or Operator Code...................................................................................................................8-3
Changing a Master, Manager, or Operator Code...............................................................................................................8-4
Adding an RF Key to an Existing User...............................................................................................................................8-4
Deleting a Master, Manager, or Operator Code.................................................................................................................8-4
Exiting the User Edit Mode.................................................................................................................................................8-4
SECTION 9: Testing the System ......................................................................................................9-1
Battery Test........................................................................................................................................................................9-1
Dialer Test..........................................................................................................................................................................9-1
Burglary Walk-Test (Code + [5] TEST)...............................................................................................................................9-1
Armed Burglary System Test..............................................................................................................................................9-1
Testing Wireless Transmitters............................................................................................................................................9-2
Trouble Conditions.............................................................................................................................................................9-3
To the Installer ...................................................................................................................................................................9-3
APPENDIX A: Regulatory Agency Statements ...............................................................................A-1
UL Installation Requirements............................................................................................................................................ A-1
UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault ...................................................................... A-1
UL365 Police Station Connected Burglar Alarm ............................................................................................................... A-1
UL611/UL1610 Central Station Burglary Alarm................................................................................................................. A-2
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup Requirements ........................................ A-2
APPENDIX B: Summary of System Commands ............................................................................ B-1
APPENDIX C: Specifications........................................................................................................... C-1
APPENDIX D: Contact ID Event Codes........................................................................................... D-1
TABLE OF CONTACT ID EVENT CODES........................................................................................................................D-1
Index ...........................................................................................................................................Index-1
THE LIMITATIONS OF THIS ALARM SYSTEM
LIMITED WARRANTY
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Figures
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Figure 3-1: Installing the Lock...............................................................................................................................................3-1
Figure 3-2: Cabinet Attack Resistance Considerations.........................................................................................................3-2
Figure 3-3: Mounting the PC Board.......................................................................................................................................3-2
Figure 3-4: Keypad Connections to Control Panel ................................................................................................................3-3
Figure 3-5: Using A Supplementary Power Supply...............................................................................................................3-3
Figure 3-6: Wiring Polarized Fire Devices.............................................................................................................................3-4
Figure 3-7: Wiring Nonpolarized Burglary Devices ..............................................................................................................3-5
Figure 3-8: Telephone Line Connections................................................................................................................................3-6
Figure 3-9: Wiring Connections for Zones 1-9 .......................................................................................................................3-6
Figure 3-10: 2-Wire Smoke Detector on Zone 1 .....................................................................................................................3-7
Figure 3-11: 4-Wire Smoke Detectors ....................................................................................................................................3-8
Figure 3-12: Wiring a 333PRM to the Control.......................................................................................................................3-8
Figure 3-13: Wiring a 333PRM using a 4204 ........................................................................................................................3-9
Figure 3-14: Wiring a 333PRM using a 4204 and a Power Supply ......................................................................................3-9
Figure 3-15: Wiring Latching Glassbreaks to Zone 8...........................................................................................................3-10
Figure 3-16: Polling Loop Connections to the VISTA-40 ....................................................................................................3-11
Figure 3-17: Polling Loop Connections Using One 4297 Extender Module .......................................................................3-12
Figure 3-18: Polling Loop Connections Using Multiple Extender Modules .......................................................................3-12
Figure 3-19: Installing the 5881ENHC with Tamper Protection ........................................................................................3-13
Figure 3-20: 5881 RF Receiver (cover removed) ..................................................................................................................3-14
Figure 3-21: 4204 Relay Module...........................................................................................................................................3-17
Figure 3-22: 4204CF Relay Module......................................................................................................................................3-17
Figure 3-23: Ground Start Module Connections..................................................................................................................3-18
Figure 3-24: Remote Keyswitch Wiring ...............................................................................................................................3-19
Figure 3-25: Remote Keypad Sounder Wiring.....................................................................................................................3-19
Figure 3-26: 4100SM Using a Serial Printer........................................................................................................................3-20
Figure 3-27: VIP Module Connections .................................................................................................................................3-21
Figure 3-28: UVS Connections to the Control Panel...........................................................................................................3-23
Figure 3-29: 1361 Transformer and Battery Connections ..................................................................................................3-24
Figure 3-30: 1361X10 Transformer Connections.................................................................................................................3-24
Figure 6-1: Direct-Wire Downloading Connections...............................................................................................................6-3
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Conventions Used in This Manual
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Before you begin using this manual, it is important that you understand the meaning of the following
symbols (icons).
These notes include specific information that must be followed if you are installing this system for
a UL Listed application.
U
L
These notes include information that you should be aware of before continuing with the
installation, and that, if not observed, could result in operational difficulties.
This symbol indicates a critical note that could seriously affect the operation of the system, or
could cause damage to the system. Please read each warning carefully. This symbol also
denotes warnings about physical harm to the user.
Many system options are programmed in an interactive mode by responding to
alpha keypad display prompts. These prompts are shown in a single-line box.
ZONE PROG?
1 = YES 0 = NO 0
✴
✴
00
Additional system options are programmed via data fields, which are indicated by a “star” ( )
followed by the data field number.
PRODUCT MODEL NUMBERS:
Unless noted otherwise, references to specific model numbers represent ADEMCO products.
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
1
General Description
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About the VISTA-40
The VISTA-40 is a 2-partition, UL Listed control panel with the following features:
•
•
Provides 64 zones using hardwired, polling loop and wireless.
Provides 70 user access codes
Features
Hardwire and Optional Expansion Zones
•
•
•
•
•
•
Provides 9 hardwire zones.
Supports up to 16 2-wire smoke detectors on zone 1.
Supports up to 50 2-wire latching glassbreak detectors on zone 8.
Supports up to 55 additional expansion zones using a built-in polling (multiplex) loop.
Supports up to 64 wireless zones (fewer if using hardwire and/or polling loop zones).
Provides three keypad panic keys: 1 + ✴ (A), ✴ + # (B), and 3 + # (C).
Peripherals Devices
•
•
Supports up to 16 addressable devices, (keypads, RF receivers, relay modules, etc.).
Provides 8 relays using 4204 and X-10 devices. Can activate relays in response to system events (e.g., alarm, fault,
etc.).
•
Supports the 4285/4286 VIP Module, which allows access to the system from either a remote location or on the
premises
The VIP Module is not Listed for use with the VISTA-40 Control Panel in a UL installation.
U
L
•
Supports the 4146 Keyswitch on any one of the system’s 2 partitions.
Arming/Disarming and Bypassing
Provides global arming capability (ability to arm both partitions the user code has access to in one command).
Partitioning
•
•
Can control 2 separate areas independently, each functioning as if it had its own separate control.
System Communication
•
Supports ADEMCO Contact ID; ADEMCO High Speed; ADEMCO Express; and 3+1, 4+1, and 4+2 ADEMCO and
Sescoa/Radionics Low-Speed formats.
•
Provides an Audio Alarm Verification (AAV) option that permits voice dialog between an operator at the central
station and a person at the premises. An AAV unit, such as ADEMCO UVS, is required.
Downloading
Supports upload and download capability.
•
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Event Log
•
•
•
Provides an event log (history log) that can store up to 100 events.
Can print the event log on a serial printer using a 4100SM.
Can view the event log on an alpha keypad.
Additional Features
•
•
Provides up to 20 installer-defined, custom words that can be used for zone descriptors.
Contains a built-in User’s Manual, which provides the end user with a brief explanation of the function of a key
when the user presses any of the function keys on the keypad for 5 seconds.
•
Provides trigger outputs, which may interface with Long Range Radio equipment or other devices such as keyswitch
LEDs or printer.
At least one 2-line alpha keypad (6139/6160) must be connected to the system for programming (if you are using
keypad programming), and must remain connected to the system in order to allow the primary user to program
additional user codes into the system at a later time.
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
2
Partitioning
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Theory of Partitioning
This system provides the ability to arm and disarm up to 2 different areas, as if each had its own control. These areas
are called partitions. A Partitioned system allows the user to disarm certain areas while leaving other areas armed, or
to limit access to certain areas to specific individuals. Each system user can be assigned to operate any or all partitions,
and can be given a different authority level in each.
Before anything can be assigned to those partitions, you must first determine how many partitions (1-2) are required.
Following are some facts you need to know about partitioning.
Keypads
Each keypad must be given a unique "address" and be assigned to one partition.
Zones
Each zone must be assigned to one partition. The zones assigned to a partition will be displayed on that partition’s
keypad(s).
Users
Each user may be given access to one or more partitions. If a user is to operate more than one partition and would like
to arm/disarm all or some of those partitions with a single command, the user must be enabled for Global Arming for
those partitions (when entering user codes).
A user with access to more than one partition (multiple access) can "log on" to one partition from another partition’s
keypad, provided that program field 2*18: Enable GOTO is enabled for each partition he/she wants to log on to from
another.
Setting-Up a Partitioned System
The basic steps to setting up a partitioned system are described below. If you need more information on how to program
the options, see SECTION 4: Programming.
1. Determine how many partitions the system will consist of (programmed in field 2*00).
2. Assign keypads to partitions (Device Programming in the #93 Menu Mode).
3. Assign zones to partitions (Zone Programming in the #93 Menu Mode).
4. Confirm zones are displayed at the keypad(s) assigned to those partitions.
5. Assign users to partitions.
6. Enable the GOTO feature (program field 2*18) for each partition a multiple-access user can log on to (alpha keypad
only).
7. Program partition-specific fields (see the Data Field Descriptions section).
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
3
Installing the Control
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
This section describes the procedures for mounting and wiring the control panel and all the peripheral devices.
Mounting the Control Cabinet
To mount the control cabinet, perform the following steps:
Step
Action
1
Before mounting the circuit board, remove the metal knockouts for the wiring entry that you will be using.
DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS AFTER THE CIRCUIT BOARD HAS BEEN
INSTALLED.
2
Using fasteners or anchors (not supplied), mount the control cabinet to a sturdy wall in a clean, dry area
that is not readily accessible to the general public. The back of the cabinet has 4 holes for this purpose.
To provide certificated burglary service for UL installations, refer to the special requirements and Figure 3-2
Cabinet Attack Resistance Considerations to follow. For UL Commercial Burglary installations that require
ATTACK RESISTANCE, use the cabinet included in the VISTA-ULKT kit.
U
L
Installing the Cabinet Lock
PUSH
ON LOCK
UNTIL IT
IS SEATED
SECURELY
1. Remove cabinet door, then remove the lock
knockout from the door. Insert the key into the
lock.
CHECK
SNAP
TAB
POSITION
LOCKED
PUSH
2. Position the lock in the hole, making certain
that the latch will make contact with the latch
bracket when the door is closed.
SNAP
TAB
UNLOCKED
3. When correctly positioned, push the lock until
it is held securely by its snap tabs.
CABINET DOOR
BOTTOM
STEP 1
STEP 2
Use Part Number K4445 Lock (supplied).
Figu r e 3-1: In sta llin g th e Lock
Grade A Mercantile Premises Listing Guidelines
•
•
•
The panel door must be supervised. Mount the
clip-on tamper switch (supplied) to the cabinet’s
right side wall as shown in the diagram below, and
wire it to one of the hardwire zones.
•
•
•
•
All wiring between the bell and panel must be run
in conduit. Remaining wires do not need to be run
in conduit.
All wiring that is not run in conduit must exit from
the knockout openings on the bottom or back of the
cabinet.
Use a bell with a tamper-protected housing such as
the AB12. The bell housing’s tamper switch and
inner tamper linings must also be wired to the
hardwire zone.
All unused knockouts must be plugged using the
disc plugs and carriage bolts (supplied), as
indicated in the diagram below.
Assign the tampers’ hardwire zone to a burglary
partition. Program the hardwire zone for day
trouble/night alarm (zone type 5) when only one
burglary partition is used. Program it for 24-hr.
audible alarm (zone type 7) when more than one
burglary partition is used.
Fasten the cabinet door to the cabinet backbox
using the 18 one-inch-long Phillips-head screws
(supplied) after all wiring, programming, and
checkout procedures have been completed.
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
(Shows typical local Grade A listing installation)
RUN BELL WIRES
IN CONDUIT
PLUG THIS
KNOCKOUT
TO PLUG AN UNUSED KNOCKOUT OPENING,
REMOVE KNOCKOUT AND INSTALL A PAIR OF
DISC PLUGS AND A CARRIAGE BOLT AS SHOWN.
CLIP-ON DOOR
TAMPER SWITCH
DISC PLUGS (DIMPLES IN DISC
PLUG SHOULD REGISTER INSIDE
KNOCKOUT OPENING)
CABINET
MOUNTING
HOLE
PC
BOARD
KNOCKOUT
OPENING
(4 PLACES)
PLUG THIS
KNOCKOUT
CARRIAGE BOLT
PLUG THIS
KNOCKOUT
HEX NUT AND
WASHER
CABINET SIDE WALL
(OUTSIDE)
PLUG THIS
KNOCKOUT
RUN ALL REMAINING
WIRE THROUGH HERE
cabattack-001-V0
F igu r e 3-2: Ca bin et Atta ck Resista n ce Con sid er a tion s
Grade A Mercantile Safe and Vault Listing Guidelines
•
Follow the guidelines given above for Grade A
Mercantile Premises listing.
•
For safe and vault applications, a UL Listed
contact must be used inside the cabinet through
one of the knockouts for pry-off tamper purposes.
This sensor also must be wired to a hardwire zone.
•
Mount a shock sensor such as Sentrol No. 5402 to
the control’s backbox. Follow the manufacturer’s
instructions for proper sensor mounting. This
sensor also must be wired to a hardwire zone.
Installing the Control’s Circuit Board
Notes:
To install the circuit board in the cabinet, perform the
following steps:
•
Make certain that the mounting screws are tight.
This ensures that there is a good ground connection
between the PC board and the cabinet.
Step
Action
Hang the three mounting clips on the raised
cabinet tabs. Refer to Figure 3-3 (Detail B).
1
•
Dress field wiring away from the microprocessor
(center) section of the PC board. Use the loops on
the left and right sidewalls of the cabinet for
anchoring field wiring using tie wraps (Detail C).
These steps are important to minimize the risk of
panel RF interference with television reception.
Make sure the clip orientation is exactly as
shown in the diagram to avoid damage. This
will also avoid problems with insertion and
removal of the PC board.
Insert the top of the circuit board into the slots
at the top of the cabinet. Make certain that the
board rests in the slots as indicated (Detail A).
2
3
DETAIL A
SIDE VIEW OF
BOARD INSERTED
INTO SLOTS
Swing the base of the board into the mounting
clips and secure the board to the cabinet with
the accompanying screws.
DETAIL C
SIDE VIEW
OF SLOTS
+
+
+
DETAIL B
SIDE VIEW OF SHORT
MOUNTING CLIPS
(TYP.)
hi_end_mnt-PCB
Figu r e 3-3: Mou n tin g th e P C Boa r d
3-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
Installing the Keypads
•
Up to 31 addressable keypads (addresses 00-30)
may be used (you may need to use an auxiliary
power supply if the 750mA aux. output is
Addressing the Keypads
The keypads will not operate until they are
physically addressed and enabled in the
system’s Device Programming in the #93 Menu
Mode.
exceeded). The following keypads may be used:
•
2-line alpha display, 6139/6160
Set each keypad for an individual address (00-15)
according to the keypad’s instructions. Set an alpha
keypad for address 00 and other keypads for higher
addresses. Any keypads set for address 02 and above
will appear blank until they are enabled in the system’s
program. Each keypad must be set for a different
address.
•
•
The length of all wire runs combined,
regardless of the wire gauge, must not
exceed 2000 feet when unshielded quad
conductor cable is used (1000 feet if
unshielded cable is run in conduit, which
acts a shield, or if shielded cable is used).
If more than one keypad is wired to one run,
then the above maximum lengths must be
divided by the number of keypads on the run
(e.g., the maximum length is 225 feet if two
keypads are wired on a #22 gauge run).
•
Do not set any keypads to address 31
(nonaddressable mode). They will interfere
with other keypads (as well as other devices)
connected to the keypad terminals.
•
If an “OC” or “OPEN CIRCUIT” message is
present on a keypad, data from the control is
not reaching the keypad. Please check your
wiring.
To wire the keypads, perform the following steps:
Step
Action
1
Determine wire gauge by referring to the
Wire Run Length/Gauge table below.
Wire Run Length/Gauge Table
Supplementary Power Supply for Additional Keypads
When the control’s auxiliary power load for all devices
exceeds 750mA, you can power additional keypads from
a regulated 12VDC power supply (e.g., AD12612
(1.2A)). Use a UL Listed, battery-backed supply for UL
installations.
Connect the additional keypads as shown in Figure 3-5,
using the keypad wire colors shown. Be sure to observe
the current ratings for the power supply used.
Wire Gauge
#22 gauge
#20 gauge
#18 gauge
#16 gauge
Length
450 feet
700 feet
1100 feet
1750 feet
2
Wire keypads to a single wire run or connect
individual keypads to separate wire runs.
The maximum wire run length from the
control to a keypad, which is homerun back
to the control must not exceed the lengths
listed in the table.
•
Make connections directly to the screw
terminals as shown in Figure 3-5. Make no
connection to the keypad blue wire (if
present).
•
Be sure to connect the negative (–) terminal
on the power supply unit to terminal 7 (–) on
the control.
3
4
Run field wiring from the control to the
keypads (using standard 4-conductor cable
of the wire gauge determined in step 1).
SUPPLEMENTARY
POWER SUPPLY
CONTROL TERMINAL STRIP
AUX. AUX. DATA DATA
Connect the keypad(s) to terminals 6, 7, 8,
and 9 on the control board, as shown in
Figure 3-4.
IN OUT
+
6
–
7
–
+
8
9
RED
6
IMPORTANT:
MAKE THESE
CONNECTIONS
DIRECTLY TO
SCREW
BLACK
7
KEYPADS
GREEN
8
TERMINALS AS
SHOWN.
YELLOW
9
CONTROL
TERMINALS
TO
TO
MAIN
KEYPAD
SECONDARY
KEYPAD
Figu r e 3-4: Keypa d Con n ection s to Con tr ol P a n el
Figu r e 3-5: Usin g A Su pplem en ta r y P ower Su pply
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Installing External Sounders
The VISTA-40 provides a bell circuit output for
operating fire and burglary alarm notification
appliances. The alarm output is rated as follows:
10VDC – 14VDC, 1.7A max., power-limited.
Alarm Output Supervision
When supervision is enabled, the VISTA-40 monitors
the alarm output wiring for open and short circuit
faults while the output is inactive. The system provides
a trouble indication (Zone 70) when an open occurs; or
when a short occurs between the Bell (+) and Bell (-)
terminal wiring, or between the Bell (+) terminal wiring
and earth ground.
The output has the following options:
•
•
•
Selectable for supervision.
Selectable for confirmation of arming ding.
Selectable to chime when entry/exit or perimeter
zones are faulted.
The VISTA-40 indicates the trouble condition
regardless of whether the system is armed or disarmed.
The zone displays on the keypads, reports to the event
log, and transmits to the central station (if
•
Selectable for no timeout or timeout of 2-30
minutes.
programmed) on Partition 1. The Contact ID event code
is 321, Bell Trouble. The trouble is cleared from the
display by entering the user code + OFF.
•
•
Burglary bell circuits must be programmed
for a timeout of 16 minutes or longer.
U
L
For Household Fire and combination
Household Fire/Burglary installations, the
total current drawn from the auxiliary power,
polling loop, and alarm output combined
must not exceed 750mA.
Wiring the Alarm Output
The wiring of the alarm output depends upon whether
you are going to supervise the output or not. Use the
appropriate procedure below for your application.
•
For Household Burglary installations, the
total current drawn from the alarm output
must not exceed 1.7A. A battery must be
installed, as it supplies the current for the
combined auxiliary power, polling loop, and
alarm output in excess of 750mA.
Use only UL Listed sounding devices for UL
installations.
U
L
Compatible Alarm Indicating Devices
Model Number Device Type
Polarizing
Diode
719
Compact Outdoor Siren
(not UL Listed)
Indoor Siren
Yes
UL1023 Household Burglary Installations
For Household Burglary installations, the total current
drawn from the alarm output must not exceed 1.7A. A
battery must be installed, as the battery supplies
current from the combined auxiliary power, polling
loop, and alarm output in excess of 750mA.
747
Yes
Yes
No
AB12
Grade A Bell
System Sensor
MA 12/24D
Fire Piezo Horn
System Sensor
P12575
Fire Horn/Strobe
Fire Horn/Strobe
No
No
UL985 Household Fire or Combination Household
Fire/Burglary Installations
Wheelock
For installations that must provide UL Listed
protection, the total combined current drawn from the
alarm output, auxiliary power output, and polling loop
must not exceed 750mA in order to comply with the
battery independence requirements. If, for example,
two System Sensor PA400 piezo alarm sounders, wired
in parallel, are used (24mA total), then 726mA (750mA
– 24mA) is available for auxiliary output and polling
loop use.
AS-121575W
4
2
3
5
6
7
8
1
+
-
ALARM SOUNDER OUTPUT:
1-VDC - 13.8VDC
1.7A MAXIMUM
+
-
Non-UL Installations
BELL
For non-UL installations, the total current drawn from
this output can be up to 1.7 amps. A battery must be
installed, as the battery supplies current in excess of
750mA. Up to two 719 sirens can be used wired in
parallel.
HORN
This control complies with National Fire
U
L
Figu r e 3-6: Wir in g P ola r ized Fir e Devices
Protection Association (NFPA) requirements for
temporal pulse sounding of fire notification
appliances.
3-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
POLARIZING DIODES
(MUST MOUNT AT INDICATING DEVICE)
PANEL BELL
TO
OTHER
DEVICES
HORN
BELL
BELL
PANEL BELL
NONPOLARIZED BURGLARY
INDICATING DEVICES
POLARIZED FIRE
INDICATING DEVICE
non_polar_devices
Figu r e 3-7: Wir in g Non p ola r ized Bu r gla r y Devices
Supervising the Alarm Output
Using a Siren Driver
To wire the alarm output using the supervision feature,
perform the following steps:
To install a siren driver, perform the following steps:
Step
Action
Step
Action
1
2
Mount the siren driver in the panel’s cabinet.
1
Wire polarized fire-indicating devices to the
alarm output as shown in Figure 3-6.
Wire the siren driver to the control and to the
speaker(s). (See the driver’s instructions.)
2
3
Wire nonpolarized burglary indicating
devices to the alarm output using a polarizing
diode (two 2A diodes supplied), as shown in
Figure 3-7.
3
4
Cut the blue jumper on the upper left-hand
corner of the panel’s PC board.
Program Zone 70 with no response type (00).
Program Zone 70 with a response type of 05
(trouble by day/alarm by night).
If a device such as a siren driver with a high-
resistance trigger input (drawing less than 5mA)
is used in a UL Household Fire installation, the
siren driver must independently supervise siren
speaker wiring.
U
L
The minimum load on the alarm output must
exceed 5mA at 12V for proper supervision
operation.
Disabling the Supervision of the Alarm Output
To install the alarm output and disable the supervision
feature, perform the following steps:
Step
Action
1
Wire the devices to terminals 4 and 5,
observing polarity if necessary.
2
3
Cut the blue jumper on the upper left-hand
corner of the panel’s PC board.
Program Zone 70 with no response type (00).
Telephone Line Connections
Connect the main dialer output to telephone company
lines using the RJ31X cables supplied.
To prevent the risk of shock, disconnect phone
lines at the telco jack before servicing.
If the communicator is connected to a PABX, be
sure it has a backup power supply that can
support the PABX for 24 hours (central station)
or 60 hours (remote station). Many PABXs are
not power-backed up, and this can result in a
communication failure if power is lost.
The telephone line inputs have overvoltage
protection in accordance with UL1459, as
specified in UL985/UL1023.
U
L
Reporting Formats
The system supports the following formats:
ADEMCO Low Speed 3+1; 4+1; 4+2; Sescoa/Radionics
3+1; 4+1; 4+2; ADEMCO 4+2 Express; ADEMCO High
Speed; ADEMCO Contact ID
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Incoming
Handset
26 27
Telco Line
28
29
30
TERMINALS
ON CONTROL
EARTH GROUND
INCOMING TELCO LINE
DIRECT
CONNECT
CORD
TIP
RING
RJ31X
JACK
PREMISES
PHONES
PLUG
Figu r e 3-8: Teleph on e Lin e Con n ection s
Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9
The maximum zone resistance is 100 ohms for
zones 1 and 8, and 300 ohms for all other
zones (excluding the 2K EOL resistor).
•
Connect N.C. devices in series with the high (+)
side of the loop. The 2K EOL resistor must be
connected in series with the devices, following the
last device.
To wire burglary and panic devices to zones 1-9, connect
sensors/contacts to the hardwire zone terminals (10
through 23). See Figure 3-9. Connect N.C. and N.O.
devices as follows:
•
Connect N.O. devices in parallel (across) the loop.
The 2K EOL resistor must be connected across the
loop wires at the last device.
Red Jumper
ZONE 2 ZONE 3
ZONE 4 ZONE 5
ZONE 6 ZONE 7
ZONE 8 ZONE 9
10
11
ZONE 1
12
13
14
15
16
17
18
19
20
21
22
23
+
+
+
+
-
-
N.C.
N.C.
N.C.
N.C.
N.O.
N.O.
N.O.
N.O.
2k EOLR 2k EOLR
2k EOLR
2k EOLR
+
-
+
+
+
-
+
-
GLASS
BREAK
Fire
Usage
N.C.
N.C.
SMOKE
N.C.
N.C.
N.C.
N.O.
N.O.
N.C.
N.O.
Burg.
Usage
2k EOLR
2k EOLR
2k EOLR
N.O.
Zone resistance (Excluding EOLR):
ZONE 1,8: 100 OHMS MAXIMUM
ALL OTHER ZONES: 300 OHMS MAXIMUM
Zone response time:
2k EOLR
ZONES 1-8: 350mSec-500mSec
ZONE 9: Programmable for
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec
(default response)
Figu r e 3-9: Wir in g Con n ection s for Zon es 1-9
3-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
Using 2-Wire Smoke Detectors on Zone 1
Zone 1 can support up to 16 2-wire smoke detectors.
(+)
(-)
(+)
(-)
10
The alarm current on zone 1 supports only one
smoke detector in the alarmed state.
2-WIRE SMOKE
DETECTOR
11
Compatible 2-Wire Smoke Detectors
DETECTOR TYPE
DEVICE MODEL #
Photoelectric, direct-wire
System Sensor 2400
System Sensor 2400TH
System Sensor 2451
System Sensor 2451TH
System Sensor 1400
System Sensor 1451
System Sensor 2451
System Sensor 2451
System Sensor 1451DH
System Sensor 1100
System Sensor 1151
System Sensor 2100
System Sensor 2100T
System Sensor 2151
Figu r e 3-10: 2-Wir e Sm ok e Detector on Zon e 1
Photoelectric w/heat sensor, direct-wire
Photoelectric w/B401B base
Photoelectric w/heat sensor & B401B
Ionization, direct-wire
Using 4-Wire Smoke Detectors on Zones 1-8
You may use as many 4-wire smoke detectors as can be
powered from the panel’s Auxiliary Power output
without exceeding the output’s rating (750mA).
Ionization w/B401B base
Photoelectric duct detect (DH400 base)
Photoelectric duct detect (DH400 base)
Ionization duct detector (DH400 base)
Ionization, direct-wire
Auxiliary power to 4-wire smoke detectors is
not automatically reset after an alarm, and
therefore must be momentarily interrupted
using a 4204 Relay Module.
Ionization w/B110LP base
Compatible 4-Wire Smoke Detectors
Photoelectric, direct-wire
Photoelectric w/heat sensor, direct-wire
Photoelectric w/B110LP base
Use any UL Listed 4-wire smoke detector that is rated
for 10-14VDC operation and that has alarm reset time
not exceeding 6 seconds. Some compatible 4-wire
smoke detectors are listed below.
These smoke detectors are UL Listed for use
with the VISTA-40 and are the only 2-wire
smoke detectors that may be used.
Detector Type
Detector Model #
U
L
Photoelectric, direct wire
System Sensor 2412
Photoelectric w/heat
sensor, direct wire
System Sensor 2412TH
Wiring 2-Wire Smoke Detectors to Zone 1
Ionization, direct wire
System Sensor 1412
2K EOL resistors must be used on fire zones
and must be connected across the loop wires
of each zone at the last detector.
Wiring 4-Wire Smoke Detectors
Power to 4-wire smoke detectors must be
To wire 2-wire smoke detectors to zone 1, perform the
following steps:
U
L
supervised with an EOL device (use a System
Sensor A77-716B EOL relay module
connected as shown in Figure 3-11).
Step
Action
1
Select up to 16 2-wire smoke detectors from
the list of compatible detectors.
To wire 4-wire smoke detectors to zones 1-8, perform
the following steps:
2
3
Connect 2-wire smoke detectors across zone 1
terminals (10 and 11) as shown in Figure 3-
10. Observe proper polarity when connecting
the detectors.
Step
Action
1
Select 4-wire smoke detectors (see list of
compatible detectors shown previously in
this section).
Connect the EOL resistor at the last detector
in the loop across the zone 1 terminals. The
EOL resistor must be connected across
the loop wires at the last detector.
2
3
Connect detectors (including heat detectors,
if used) across terminals of the zone selected.
All detectors must be wired in parallel. See
Figure 3-11.
Connect the EOLR at the last detector in the
loop across the zone’s terminals. You must
connect the EOLR across the loop wires
at the last detector.
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
TO
AUXILIARY
POWER
TERMINALS
+
+
4-WIRE
SMOKE
EOL POWER
SUPERVISION
RELAY MODULE
A77-716B
DETECTORS
+
+
NOTES:
NO CONNECTION
· PROGRAM THE RELAY TO
TRANSFER ON FIRE ZONE
RESET (ACTIVATION CODE 54).
SEE 4204 RELAY MODULE
SECTION FOR DETAILS.
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST.
C
NC NO
RESET
2k
EOLR
HEAT
DETECTOR
· SECOND CODE AND OFF
ENTERED AT CONSOLE
MOMENTARILY INTERRUPTS
DETECTOR POWER.
RELAY 1, 2, 3, OR 4
4204 RELAY MODULE
+
TO
FIRE ZONE
TERMINALS
V128BP-002-V0
Figu r e 3-11: 4-Wir e Sm ok e Detector s
Using Smoke Power Reversal Module
The 333PRM reverses polarity to smoke detectors
with Integral Temp-3 Sounders. Typically, in
alarm, each draws 49-60mA of current. The
control panel supplies only enough current for one
smoke detector. In order to attach more than
one, an external power supply and an external
relay may be required.
The 333PRM Polarity Reversing Module is used to
reverse the polarity of the positive and negative
voltages powering smoke detectors. The module is for
use with 4-wire smoke detectors that employ a sounder
and voltage-reversing feature. The module is triggered
by a pulsing bell output.
Smoke Detectors Compatible with the 333PRM
Installing the 333PRM
The 333PRM may be used with the System Sensor
2112/24AT and similar models with the required
operating features previously stated.
Mount the 333PRM inside the control panel’s cabinet or
in a separate cabinet using the double-sided tape
provided. Wire the 333PRM as shown in Figures 3-12,
3-13 or 3-14. Refer to the 333PRM Installation
Instructions for detailed information on the installation
of the module.
CONTROL PANEL
6
7
4
NC
MOMENTARY
RESET SWITCH
8
7
6
5
4
3
+
–
4-WIRE SMOKE
EOL POWER
DETECTORS
SUPERVISION
RELAY MODULE
+
+
A77-761B
-
-
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST
-2
+1
P1
2000
OHM
EOLR
JUMPER
HEAT
DETECTOR
JUMPER P1 ON
333 MODULE
MUST BE IN
-
+
"B" POSITION
FOUR-WIRE DETECTOR CIRCUIT
TO FIRE ZONE
TERMINALS
Figu r e 3-12: Wir in g a 333P RM to th e Con tr ol
3-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
CONTROL PANEL
6
7
4
8
7
6
5
4
3
+
–
4-WIRE SMOKE
DETECTORS
EOL POWER
SUPERVISION
RELAY MODULE
A77-761B
+
+
-
-
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST
-2
+1
P1
2000
OHM
EOLR
JUMPER
HEAT
DETECTOR
JUMPER P1 ON
333 MODULE
MUST BE IN
-
+
"B" POSITION
FOUR-WIRE DETECTOR CIRCUIT
TO FIRE ZONE
TERMINALS
1
2
3
4
12
NO NC
C
4204
Figu r e 3-13: Wir in g a 333P RM u sin g a 4204
CONTROL PANEL
6
7
4
8
7
6
5
4
3
+
–
4-WIRE SMOKE
DETECTORS
EOL POWER
SUPERVISION
RELAY MODULE
A77-761B
+
+
-
-
SHOWN POWERED.
RELAY OPENS WHEN
POWER IS LOST
-2
+1
P1
JUMPER P1 ON
333 MODULE
MUST BE IN
2000
OHM
EOLR
JUMPER
"B" POSITION
HEAT
DETECTOR
-
+
FOUR-WIRE DETECTOR CIRCUIT
TO FIRE ZONE
TERMINALS
+
USE A 12VDC,
BATTERY-BACKED,
UL LISTED POWER
SUPPLY.
Figu r e 3-14: Wir in g a 333P RM u sin g a 4204 a n d a P ower Su p p ly
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Using 2-Wire Latching Glassbreaks on Zone 8
GLASSBREAK
DETECTOR
Zone 8 can support 2-wire glassbreak detectors. The
zone provides enough standby current to power up to 50
2-wire glassbreak detectors meeting the requirements
listed below.
ZONE 8
2000
OHMS
EOLR
(+)
(-)
21
22
LATCHING TYPE GLASS
BREAK DETECTOR LOOP
Compatible Glassbreak Detectors
Use detectors that meet the following ratings:
Standby
Voltage:
5VDC–13.8VDC
F igu r e 3-15: Wir in g La tch in g Gla ssbr ea k s to Zon e 8
Standby
Resistance:
Greater than 20k ohms (equivalent
resistance of all detectors in parallel)
•
•
The alarm current provided by zone 8
supports only one glassbreak detector in
the alarmed state.
Alarm
Resistance:
Less than 1.1k ohms (see note below)
Do not use other N.O. or N.C. contacts
when using glassbreak detectors on zone
8. Other contacts may prevent proper
glassbreak detector operation.
Alarm
Current:
2mA–10mA
Reset Time:
Less than 6 seconds
NOTES:
To wire 2-wire latching glassbreak detectors to zone 8,
perform the following steps:
•
You can use detectors that exceed 1.1k ohms in
alarm, provided they maintain a voltage drop of
less than 3.8 volts in alarm.
Step
Action
•
The ASC-SS1 detector has been tested and found to
be compatible with these ratings.
1
Select compatible 2-wire glassbreak
detectors that meet the requirements stated
previously.
2
3
Connect detectors across zone 8 (terminals
21 and 22). See Figure 3-15.
Connect the EOL resistor at the last detector
in the loop across the zone’s terminals. You
must connect the EOL resistor across
the loop wires at the last detector.
Installing RPM Devices
The polling loop provides both power and data to the
RPM devices, and is constantly monitoring the status of
all zones enabled on the loop. The maximum current
draw of all devices on the polling loop cannot total more
than 64mA (unless the system uses a 4297 Polling Loop
Extender Module).
Compatible Polling Loop Devices
Model Number Type
4208
8-Zone Expander
4190WH
4278
2-Zone Expander
Quad PIR
4275
Dual PIR
Devices that can be programmed via either DIP
switches or the built-in unique serial number
must be set for the serial number mode
operation.
4194
Surface-Mount Reed Contact (Wide Gap)
Extender Module
4297
4192SD
4192SDT
Photoelectric Smoke Detector Devices
Photoelectric Smoke Detector w/Heat
Detector
All devices on the polling loop must be wired in parallel
to the [+] and [-] polling loop terminals of the control
panel (24 and 25). You can wire from device to device,
or have multiple branches connected directly to the
control panel in a star configuration.
4192CP
Ionization Smoke Detector
4101SN
Serial Number Single-Output Relay Module
Universal 8-Zone Expander
4208U
4939SN-BR
4939SN-GY
4191SN-WH
4959SN
Serial Number Surface-Mount Reed
Contacts
Serial Number Recessed Reed Contact
Aluminum Overhead Door Contact
3-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
To install polling loop devices, perform the following steps:
Model Number Type
7500
Single Technology Glassbreak Detector
Step
Action
9500
Dual Technology Glassbreak Detector
Universal Group Zoning Module
Serialized 2-Zone Expander
Serialized 1-Zone Expander
Serialized 2-Zone Expander
Serialized PIR
1
Select devices from the list of compatible
devices shown previously.
4209U
4193SN
4293SN
4190SN
998MX
2
Set the DIP switches in the device (if
required). Refer to the device’s instructions
for the DIP Switch Tables.
3
4
Mount each device in the desired location.
Refer to the device’s instructions.
•
•
The 4208 must be mounted either inside the
control panel’s cabinet or in a separate
enclosure that has a tamper-supervised cover.
U
L
Run wires from the control panel to each
device on the polling loop (see Figure 3-16).
No individual wire run may exceed the
lengths shown in the following table.
The 4190WH right loop must not be used, and
the left loop must be EOLR-supervised.
•
•
•
The 4278 right loop cannot be used.
The 4194 is not UL Listed.
Maximum Polling Loop Wire Runs
Wire Gauge
#22 gauge
#20 gauge
#18 gauge
#16 gauge
Max. Length
650 feet
The 4297 must be powered from the control
panel’s Auxiliary Power Output or from a UL
Listed supplementary power supply.
950 feet
1500 feet
2400 feet
•
•
The 7500 and 9500 detectors are not UL Listed.
For new polling loop installations, always use
twisted pair wiring. In many cases, existing
non-twisted pair wiring may be used, but it is
more susceptible to interference from other
sources, and may be problematic in installations
with long wire runs or in high noise
5
Wire each device to the polling loop, making
sure of the correct polarity (refer to the
device’s instructions).
NOTE: If you are using serial number
devices, and intend to enroll each device
through the keypad automatically, wire no
more than 25 of these devices to the
control at a time. Then power up and
program them before connecting the next 25.
Leave previously enrolled devices connected.
If you intend to manually enter the serial
numbers through the keypad or through
Compass downloading software, all the
devices may be connected before powering
up to program.
environments.
•
Always locate polling loop wiring at least six
inches (15cm) of AC power, telephone, or
intercom wiring. The polling loop carries data
between the control panel and the devices;
interference on this loop can cause an
interruption of communication. The polling loop
can also cause outgoing interference on the
intercom or phone lines. If this spacing cannot
be achieved, shielded wire must be used. (Note
that the maximum total wire length supported is
cut in half when shielded wire is used.)
21
22
23
24
25
+
-
POLLING LOOP RATING:
128mA MAXIMUM
•
•
No more than 64mA may be drawn on any
individual wire run.
When a star configuration is used, the total
length of all wire runs combined cannot exceed
4000 ft (2000 ft. if you are using unshielded wire
in conduit or shielded wire).
4190
RPM
TO RIGHT LOOP
IMPORTANT NOTE: If the installation exceeds or deviates
from these parameters, refer to the application note on the
Honeywell website for additional information. To access
the application note:
4192SD
SMOKE
4278
PIR
1. Go to the honeywell.com/security website
2. Click the Honeywell Security & Custom Electronics link.
3. Click the Commercial link.
Figu r e 3-16: P ollin g Loop Con n ection s to th e
VISTA-40
4. Click the Documentation link.
5. Click the V-Plex Application Note.
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Polling Loop Supervision
Using the 4297 Polling Loop Extender
A short on the polling loop is indicated by a trouble on
zone 997 and reports as a trouble condition only. If
annunciation is desired, program the zone as type 05.
If a device on the polling loop fails (the panel cannot
"see" that device), the system displays a trouble
condition for all zones on that device. If the panel is
armed when a device fails, and the zone is a burglary
zone, the will go into alarm
The 4297 Polling Loop Extender may be used to provide
additional polling loop current, to extend the polling
loop wire run length, and/or to provide individual
electrically isolated polling loops. Refer to Figures 3-17
and 3-18, to follow.
Be sure to include the total current drawn on
the polling loop when figuring the total auxiliary
load on the panel’s power supply.
A trouble on zone 97 prevents a partition from
being armed, unless all polling loop zones on
that partition are bypassed.
INPUT POLLING LOOP
EXTENSION POLLING LOOP
TO
RPM
RPM
RPM
RPM
OTHER
RPMS
CONTROL PANEL
4297
INPUT LOOP LIMITS:
EXTENSION POLLING LOOP LIMITS = SAME AS INPUT LOOP
• 64 mA MAX. LIMIT CURRENT TO 64mA ON ANY
INDIVIDUAL WIRE RUN.
• NO MORE THAN 55 DEVICES MAY BE USED.
•
NO INDIVIDUAL WIRE RUN CAN EXCEED:
GAUGE LENGTH
COMBINED INPUT AND EXTENSION LOOP LIMITS:
#22
#20
#18
#16
650 FT
950 FT
1500 FT
2400 FT
• NO MORE THAN 55 DEVICES COMBINED.
• TOTAL LENGTH OF ALL WIRE RUNS ON BOTH LOOPS
COMBINED CANNOT EXCEED 5200 FT. (2600 FT. IF
USING UNSHIELDED WIRE IN CONDUIT, OR IF USING
SHIELDED WIRE).
• TOTAL LENGTH OF ALL WIRE RUNS COMBINED CANNOT
EXCEED 5200FT. (2600FT. IF USING UNSHIELDED WIRE).
Figu r e 3-17: P ollin g Loop Con n ection s Usin g On e 4297 Exten d er Mod u le
•
DO NOT CONNECT 4297 MODULES IN
SERIES (i.e., DO NOT CONNECT ONE
MODULE'S EXTENSION LOOP TO
ANOTHER MODULE'S INPUT LOOP.)
EXTENSION POLLING LOOP #1
RPM
4297
INPUT POLLING LOOP
CONTROL PANEL
EXTENSION POLLING LOOP #2
RPM
4297
COMBINED INPUT AND EXTENSION LOOP LIMITS:
NO MORE THAN 55 DEVICES COMBINED ON THE INPUT LOOP AND EXTENSION
LOOP #1. NO MORE THAN 55 DEVICES COMBINED ON THE INPUT LOOP AND
EXTENSION LOOP #2.
•
• TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT LOOP AND EXTENSION LOOP #1
COMBINED CANNOT EXCEED 5200 FT. (2600 FT. IF USING UNSHIELDED WIRE IN
CONDUIT, OR SHIELDED WIRE). TOTAL LENGTH OF ALL WIRE RUNS ON THE INPUT
LOOP AND EXTENSION LOOP #2 COMBINED CANNOT EXCEED 5200 FT. (2600 FT. IF
USING UNSHIELDED WIRE IN CONDUIT, OR SHIELDED WIRE).
Figu r e 3-18: P ollin g Loop Con n ection s Usin g Mu ltip le Exten d er Mod u les
NOTE: The input loop limits stated in Figure 3-17 apply to Figure 3-18 as well.
3-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
Wireless Zone Expansion
•
•
Use two identical receivers to provide either a
greater area of coverage or redundant protection.
They must be set for different addresses.
The 5881ENHC RF Receiver and the 5869 Holdup
U
L
Switch Transmitter are listed for UL Commercial
Burglary applications. All other RF receivers and
transmitters are not listed for UL Commercial
Burglary applications.
Any zone from 1 to 64 can be used as a 5800 Series
wireless zone, with the exception of zone 64
(reserved for a wireless keypad).
The following table lists the receivers that may be used
and the number of zones they support.
5800 Series Receivers
RF System Installation Advisories
•
•
•
Place the receiver in a high, centrally located area.
Do not place it on or near metal objects. This will
decrease the range and/or block transmissions.
Receiver
5881L
Zones
up to 8
up to 16
up to 64
5881M
5881H
Install the RF receiver at least 10 feet from the
control panel or any keypads, to avoid interference
from the microprocessors in these units.
In Canada, 5800 systems must use 5882 Series
receivers: 5882L/5882H. Information to the 5881
Receivers applies as well to the 5882 Receivers.
Both receivers use the same transmitters.
If dual receivers are used:
a. They must be at least 10 feet from each other,
as well as from the control panel and remote
keypads.
b. Each receiver must be set to a different device
address. The receiver set to the lower address
is considered the 1st RF receiver for supervisory
purposes.
RF System Operation and Supervision
The 5800 RF system operation has the following
characteristics:
•
•
•
The receiver responds to a frequency of 345MHz.
The receiver has a nominal range of 200 feet.
c. The House IDs must be the same.
d. Using two receivers does not increase the
number of transmitters the system can support
(63 zones using the 5881H, plus a wireless
keypad).
Supervised transmitters send a supervisory signal
every 70-90 minutes.
•
Zones 88 and 90 are used to supervise the RF
reception of receivers 2 and 1, respectively. The
reception is supervised for two conditions:
Installation and Setup of the 5881 RF Receivers
1. The receiver goes “deaf” (doesn’t hear from any
transmitter) within a programmed interval of
time (defined by program field 1*30).
Take note of the address you select for the RF
receiver, as this address must be enabled in
the system’s Device Programming in the #93
Menu Mode.
2. Proper RF reception is impeded (i.e., jamming
or other RF interference). The control checks
for this condition every 45 seconds.
A response type (05 Day/Night) must be
programmed for zones 90 (1st receiver) and 88
U
L
(2nd receiver) for UL installations.
•
The 5881ENHC receiver contains front and back
tampers that permit its use in commercial burglary
installations.
•
•
You may only mount the 5881ENHC its own plastic
housing. Otherwise, the receiver constantly reports
a tamper condition.
The control checks the receiver connections about
every 45 seconds. The receiver supervisory zone is
89 and 91 for receivers 2 and 1, respectively.
SCREW
NOTE: These zones must be programmed with a
response type (e.g., type 05 Day/Night Trouble)
before they supervise the connection to the receiver.
5881ENHC-001-V0
Figu r e 3-19: In sta llin g th e 5881ENHC with Ta m p er
P r otection
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
To install the 5881 RF receiver, perform the following
steps:
Step
Action
Step
Action
4
Connect the receiver’s wire harness to the
keypad terminals (6, 7, 8, and 9). Plug the
connector at the other end of the harness into
the receiver.
1
Mount the receiver, following the advisories
stated previously.
2
3
Set the DIP switches in the receiver for the
address (01-07). See Figure 3-20.
5
Refer to the Installation Instructions
provided with the receiver for installations
regarding antenna mounting, etc.
Make sure the address setting is not
being used by another device (keypad,
relay module, etc.).
If installing a 5881ENHC, install a flat-head
screw (supplied) in the case tamper tab as
shown in Figure 3-19. When the receiver is
pried from the wall, the tamper tab will break
off and remain on the wall. This will activate
a tamper switch in the receiver and cause
generation of a tamper signal. Note that this
signal will also be generated when the
receiver’s front cover is removed.
ANTENNAS
TO CONTROL'S REMOTE KEYPAD
CONNECTION POINTS.
USE MAX. of 220 ft. [67m of #22 (0.64mm)
WIRE or 550 ft. (168m) of #18 (1mm) WIRE
FOR EACH RUN. OBSERVE 20 ft. MAX.
FOR COMMERCIAL FIRE INSTALLATIONS.
(SEE RECEIVER'S INSTRUCTIONS.)
INSERT IN
RIGHT-HAND
TERMINALS
CIRCUIT
BOARD
MOUNTING
HOLES
YELLOW
RED
BLACK
DIP SWITCH WHITE AREAS = SWITCH
HANDLES. POSITION 2-4 DETERMINE
RECEIVER'S ADDRESS. CONSULT
CONTROL'S INSTRUCTIONS FOR
ADDRESS TO USE. DIP SWITCH BELOW
SHOWN SET FOR ADDRESS "0."
GREEN
WIRING
OPENING
RECEIVER ADDRESS SETTINGS
(" - " MEANS OFF)
SWITCH
POSITION
0
1
2
3
4
5
6
7
PRESENT ONLY ON 5881EH (SEE TEXT AT LEFT)
5
4
ON
ON
ON
ON
ON ON
ON ON
3
DIP SWITCH
INTERFERENCE
INDICATOR LED
PLUG & SOCKET
ON ON ON ON
FOR FUTURE USE
2
1
DIP SWITCH #5 (PRESET ONLY ON 5881EH)
ON: SETS 5881EH FOR USE IN COMMERCIAL
FIRE APPLICATIONS (SEE THE RECEIVER'S
INSTRUCTIONS)*.
OFF: USE IN NON-COMMERCIAL FIRE
INSTALLATIONS.
* FOR COMMERCIAL FIRE APPLICATIONS
THE 5881EH PC BOARD MUST BE MOUNTED
IN A SEPARATE CABINET (SEE RECEIVER'S
INSTRUCTIONS FOR DETAILS).
Figu r e 3-20: 5881 RF Receiver (cover r em oved )
3-14
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
5800 Series Transmitter Setup
Installing the 5800TM Module
5800 Series transmitters have the following
characteristics:
Installation of this module is necessary only if you are
using a 5827BD or 5804BD Bi-directional device.
•
Transmitters have built-in serial numbers that
must be enrolled in the system using the #93 Menu
Mode Programming, or input to the control via the
downloader.
The address for the 5800TM must be enabled
in the control’s Device Programming in the #93
Menu Mode as a keypad and then assigned to
a partition.
•
•
Transmitters do not have DIP switches (except
5827, described separately).
Some transmitters, such as the 5816 and 5817, can
support more than one “zone” (referred to as loops
or inputs). Each loop must be assigned a different
zone number.
For button-type transmitters (wireless keys), such
as the 5804 and 5804BD, you must assign a unique
zone number to each individual button used on the
transmitter.
To install the 5800TM, perform the following steps:
Step
Action
1
Mount the unit using its accompanying
mounting bracket near the RF receiver.
•
The 5800TM must not be installed within
the control cabinet. It must be between
one and two feet from the receiver’s
antennas.
Transmitter Input Types
2
3
Set the module for the appropriate address.
For Address Setting 28 cut the red jumper;
for Address 29 cut the white jumper; for
Address 30 cut both jumpers.
All transmitters have one or more unique factory-
assigned input (loop) codes. Transmitters can be
programmed as one of the following types:
Type
Description
Connect the module’s wire harness to the
keypad terminals (6, 7, 8, and 9). Plug the
connector at the other end of the harness into
the module.
RF
Sends periodic check-in signals, as well as
fault, restore, and low-battery signals. The
transmitter must remain within the receiver’s
range.
(Supervised
RF)
House ID Sniffer Mode
UR
Sends all the signals that the RF type does, but
the control does not supervise the check-in
signals. The transmitter may therefore be
carried off-premises.
(Unsupervised
RF)
This mode applies only if you are using a wireless
keypad (e.g., 5827) or bi-directional devices (e.g.,
5804BD). Use the House ID Sniffer mode to make sure
you do not choose a House ID that is in use in a nearby
system. The House ID must be programmed for the
receiver in Device Programming in the #93 Menu Mode.
BR
These send only fault signals. They do not
send low-battery signals until they are
activated. The transmitter may be carried off-
premises.
(Unsupervised
Button RF)
To enter House ID Sniffer mode, enter your Installer
Code + [#] + [2].
Transmitter Supervision
The receiver now “sniffs” out any House IDs in the area
and displays them. Keep the receiver in this mode for
about 2 hours. Use a House ID that is not displayed.
Exit the Sniffer mode by entering your Installer Code
+ OFF.
Supervised RF transmitters send a check-in signal to
the receiver at 70–90 minute intervals. If at least one
check-in is not received from each supervised
transmitter within a programmed period (field 1∗31),
the “missing” transmitter number(s) and “CHECK” or
“TRBL” are displayed. Unsupervised RF transmitters
(5802MN, 5804) may be carried off the premises.
As Sniffer mode effectively disables RF point
reception, Sniffer mode cannot be entered
while any partition is armed.
Some transmitters have built-in tamper protection, and
annunciate a “CHECK” condition if covers are removed.
If a loss of supervision occurs on a transmitter
programmed for Fire, it reports in Contact ID as
a Fire Trouble (373), not Loss of Supervision
(381), to the central station.
3-15
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Transmitter Battery Life
Some transmitters (e.g., 5802, 5802CP, and 5803)
contain long-life but nonreplaceable batteries. At the
end of their life, the complete unit must be replaced
(and a new serial number enrolled at the control).
Batteries in the wireless transmitters may last from 4
to 7 years, depending on the environment, usage, and
the specific wireless device being used. Factors such as
humidity, high or low temperatures, as well as large
swings in temperature may all reduce the actual
battery life in a given installation.
Button-type transmitters (e.g., 5801, 5802, 5802CP and
5803) should be periodically tested, as these
transmitters do not send supervisory check-in signals.
The wireless system can identify a true low battery
situation, thus allowing the dealer or user of the system
time to arrange a change of battery and maintain
protection for that point within the system.
To test the transmitters using the Transmitter
ID Sniffer mode and the Go/NoGo Test Mode,
see SECTION 10: Testing the System for the
procedures.
Compatible 5800 Series Transmitters
Model
Product
Input Type
UR or RF
BR Only
Model
Product
Input Type
5801
Panic Transmitter
5806/5807/
5808
Wireless Photoelectric Smoke
Detectors
RF
5802
Pendant (Personal Emergency
Transmitter)
5816
Door/Window Transmitter
Miniature Door/Window Transmitter
Temperature Sensor Transmitter
Multi-Point Universal Transmitter
Recessed Transmitter
RF
5802CP
Belt Clip (Personal Emergency
Transmitter)
5816MN
5816TEMP
5817
5802MN
Miniature (Personal Emergency
Transmitter)
UR or RF
UR or RF
RF
5818
RF
5802MN2
Miniature (Personal Emergency
Transmitter)
5827
Wireless Keypad
House ID
House ID
RF
5827BD
5849
Wireless Bi-directional Keypad
Glassbreak Detector
5804
Wireless Key Transmitter
BR Only
BR Only
5804BD
Wireless Key Bi-directional
Transmitter
5850
Glassbreak Detector
RF
5890
PIR Detector
RF
5804BDV
Wireless Key Bi-directional
Transmitter with Voice
BR Only
5890PI
PIR Detector with Pet Immunity
RF
Installing Relay Devices
The VISTA-40 support up to 8 relays. Each device must
be programmed as to how to act (ACTION), when to
activate (START), and when to deactivate (STOP). The
4204 and/or X-10 devices may be used as relay devices.
To install the relay modules, see Figures 3-21 and 3-22
and perform the following steps:
Step
Action
1
Set the 4204 or 4204CF’s DIP switches for a
device address 01-15.
Installing the 4204 Relay Modules
Do not use an address being used by another
device (keypads, RF receivers, etc.).
Each 4204 module provides 4 relays with Form C
(normally open and normally closed) contacts.
2
3
Mount the 4204 and 4204CF Modules per the
instructions provided with them.
The relay module will not operate until the
device address you have set the DIP switches
for is enabled in the control’s Device
Connect the module’s wire harness to the
control (6, 7, 8, and 9). Plug the connector
(other end of harness) to the module.
Programming in the #93 Menu Mode.
If you are mounting remotely, homerun each
module to the control. The table below shows
the maximum wire run lengths. Refer to the
instructions provided with the 4204CF for its
maximum permissible wire lengths.
Wire Gauge Maximum Length
#22
#20
#18
#16
125 feet
200 feet
300 feet
500 feet
3-16
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
SWITCH
POSITION
4 2 0 4 C F A D D R E S S S E T T I N G S
SWITCH
POSITION
4 2 0 4 A D D R E S S S E T T I N G S
©
©
©
©
("—" means "OFF")
("—" means "OFF")
OFF
ON
OFF
ON
0
1
2
3
—
4
5
—
6
ON
—
7
—
8
9
10 11
12 13 14 15
0
1
2
3
—
4
5
—
6
ON
—
7
—
8
9
10 11
12 13 14 15
©
©
ON
—
ON
—
ON
ON
—
ON
—
ON
—
—
ON
—
ON
—
—
—
—
—
2
3
4
5
ON
—
ON
—
ON
ON
—
ON
—
ON
—
—
ON
—
ON
—
—
—
—
—
2
3
4
5
©
©
©
©
©
©
ON ON
ON ON
ON ON
—
ON
—
—
ON ON
ON ON
—
ON ON
ON ON
ON ON
ON ON
—
ON
—
—
ON ON
ON ON
—
ON ON
ON
ON
ON
—
—
ON ON
—
—
—
—
—
ON
ON
ON
—
—
ON ON
—
—
—
—
—
ON ON
ON ON
ON
—
—
—
—
—
ON ON
ON ON
ON
—
—
—
—
—
- ALARM POLARITY
SHOWN
–
©
DIP SWITCH
- EACH OUTPUT
PROVIDES
RELAY
NOTIFICATION
APPLIANCE B
2K EOLR
C
4204
NC
NC
FOR SETTING DEVICE
ADDRESS AND
ENABLING/DISABLING
TAMPER
4
©
STYLE Y
NC
NO
C
DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER
TYPICAL
SUPERVISION
#610-7
+
(SHOWN "OFF")
- EACH OUTPUT
RATED 1.2A MAX
- USE
NOTIFICATION
APPLIANCES
COMPATIBLE
WITH
POLARIZED
NOTIFICATION
APPLIANCE
–
NC
NC
RELAY
COVER TAMPER (REED) SWITCH
NC
NO
3
COVER TAMPER (REED) SWITCH
4-PIN CONSOLE PLUG
©
NOTIFICATION
APPLIANCE A
2K EOLR
4-PIN CONSOLE PLUG
C
RELAY
©
NOTIFICATION
APPLIANCE
POWER SUPPLY
VOLTAGE
EITHER OR BOTH
CAN BE USED
NC
NO
C
2
#610-7
+
©
©
EITHER OR BOTH
+
TB1
NC
NC
CAN BE USED
RATING
©
RELAY
©
POWER FOR
–
13 14 15 16
TB1
}
NOTIFICATION APPLIANCE A,
NOTIFICATION APPLIANCE B
8-28VDC OR VFW. UP TO 2.4A
DEPENDING ON BELL CURRENT
NC
1
L
13 14 15 16
NO
YEL
DATA IN
FROM CONTROL
TB2
L
BLK
GRN
RED
YEL
BLK
GRN
RED
TB2
DATA IN
(–) GROUND
NOTIFICATION APPLIANCE AND
CONSOLE DATA OUTPUTS ARE
POWER LIMITED
FROM CONTROL
DATA OUT
TO CONTROL
(–) GROUND
(+) 12V; SUPPLIES POWER TO MODULE
CIRCUITRY (INCLUDING NOTIFICATION
APPLIANCE RELAY COILS). CURRENT
DRAIN AT 12V IS: 25 mA + (80 mA PER
ACTIVE OUTPUT)
DATA OUT
TO CONTROL
(+) 12V
Figu r e 3-21: 4204 Rela y Mod u le
Figu r e 3-22: 4204CF Rela y Mod u le
Installing X10 Devices
X-10 devices are either plugged into standard AC
outlets or wired into the AC electrical system by a
X-10 devices require the use of a 1361X10 transformer
in place of the regular 1361 transformer.
licensed electrician, depending on the type of device
used.
X-10 devices respond to “on” and “off” commands sent
from the panel through the 1361X10 transformer.
To connect the 1361X10 transformer, see Connecting the
Transformer, later in this section.
Note each device’s House and Unit Code
setup, as these codes will be used to program
the devices in Output Programming in #93
Menu Mode described in the Programming
Guide.
Installing the Ground Start Module
To install the 675 Ground Start Module, perform the
following steps:
The Ground Start Module is not intended for
U
L
use in UL Listed applications.
Step
Action
1
Determine which side of the telephone line
is the RING side by connecting the (+) lead
of a DC voltmeter to earth ground, and the
(-) lead to one side of the telephone line.
Output 1 may be used to trigger an optional 675
Ground Start Module for installations having telephone
lines that require ground start instead of loop start
operation to obtain a dial tone from the telco central
office.
The wire that reads + 50VDC is the
RING side.
When the panel has a message to transmit to the
central station, it seizes the line, goes off hook, and then
triggers the 675 Module to connect the RING side of the
telephone line to earth ground. The panel causes the
module to break the connection between RING and
earth ground when it obtains a dial tone.
2
3
Connect the 675 Ground Start Module to
the panel’s J7 connector trigger output 1, to
auxiliary power, and to the RING side of
the telephone line as shown in Figure 3-23.
Program field 1✳46 Auxiliary Output
Enable with a [0].
You cannot use Output 1 for the Ground Start if
you are using it for Open/Close or an AAV
module.
3-17
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
J7 CONNECTOR
4142TR
CABLE
GRAY (GROUND)
GROUND START
TRIGGER
675
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
GROUND
START
MODULE
BLUE
TO AUX. POWER
TERM. 7
BLACK
VIOLET
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)
(CUT ORANGE
JUMPER)
TO AUX. POWER
TERM. 6
(50mA CURRENT DRAW)
IF USED:
1. OUT 1 IS NO LONGER
USABLE FOR SMOKE DETECTOR RESET
(SEE FIELD 1*46).
TO
TELCO
RING
TO
EARTH
GROUND
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
3. THE 675 IS NOT UL LISTED.
F igu r e 3-23: Gr ou n d Sta r t Mod u le Con n ection s
Installing a Remote Keyswitch
A UL-Listed remote keyswitch, such as the 4146, can be
used for remote arming/disarming of the burglary
portion of the system and for silencing alarms. The
keyswitch can operate in only one particular partition.
Keyswitch Tamper Operation
The tamper switch need not be used for fire or UL
Household Burglary installations. For UL Commercial
Burglary installations, the tamper switch must be
wired to a zone (zone 6 in Figure 3-24).
The keyswitch is wired across zone 7. This zone is no
longer available as a protection zone. Be sure to
program Zone 7 with a response type (e.g., type 10).
Program that zone for Day Trouble/Night Alarm
(response type 5). When the keyswitch is removed from
the wall, the tamper switch opens, causing an alarm or
trouble on the zone. This also causes the control to
disable keyswitch operation until the tamper is restored
and the associated partition is disarmed.
Operation
•
A momentary short across zone 7 arms the
partition in the AWAY mode, and a short held for
more than 3 seconds arms the partition in STAY
mode. A subsequent short disarms the partition.
Wiring for the Remote Keyswitch
•
•
The keyswitch LEDs indicate the partition’s status
(see table below).
To install the 4146 keyswitch, perform the following
steps:
A momentary short across Zone 7 silences alarm
bell and keypad sounds, and disarms the system if
it was armed. A subsequent short across Zone 7
clears the alarm memory indication and resets 2-
wire smoke and glassbreak detectors (if used).
Step
Action
1
Connect the 4146 to the panel as shown in
Figure 3-24.
2
If you are using the tamper, make sure it is
connected to a zone.
LED Indications
Green
On
Red
Indication
Off
Disarmed & Ready
Disarmed & Not Ready
Armed Away
Off
Off
Off
On Steady
Slow Flash
Rapid Flash
Off
Armed Stay
Off
Alarm Memory
The keyswitch reports as user 0, if Open/Close
reporting is enabled in field ✳40.
3-18
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
TO AUX POWER
(TERMINAL 6)
YELLOW
RED
(ARMED)
WHITE
GREEN
(READY)
820
ohms
820
ohms
RED
BLACK
TO J7 / OUT 2
TO J7 / OUT 4
2K ELOR
ZONE
ZONE
+
TAMPER SWITCH
(CONTACTS CLOSE WHEN
SWITCH DEPRESSED).
LOCK SWITCH
(NORMALLY OPEN)
TO ZONE 7 (+)
(TERMINAL 20)
2K ELOR
J7_keyswitch
Figu r e 3-24: Rem ote Keyswitch Wir in g
Remote Keypad Sounder
An optional Amseco PAL 328N Piezo Sounder can be
used to duplicate the sounds produced by the keypad’s
built-in sounder. The panel will remote all sounds (e.g.,
alarm, trouble, chime, entry/exit, etc.) produced by the
keypad’s built-in sounder except for the short beeps
associated with keypad key depression. One application
of this feature might be to produce chime sounds at a
distant location from the panel’s keypads.
To duplicate the keypad sounds for a particular
partition, program that partition number in field ✳15.
Program field 1✳46 Auxiliary Output Enable with a [2].
J7 CONNECTOR
IF USED.
4142TR CABLE
GRAY (GROUND)
1. OUT 1 IS NO LONGER
USABLE FOR SMOKE
DETECTOR RESET
OR GROUND START
(SEE FIELD 1*46).
2. OUT 2 & 4 CAN NO LONGER
BE USED TO PROVIDE
ALARM TRIGGERS.
YELLOW (OUT 1)
WHITE (GROUND)
RED (OUT 2)
BLACK
–
AMSECO PAL-328N
PIEZO SOUNDER
Remote Keypad Sounder Setup
GREEN (GROUND)
BROWN (OUT 3)
BLUE (GROUND)
BLACK (OUT 4)
+
To setup for a remote keypad sounder, connect the piezo
sounder to the panel’s positive auxiliary power output
and to Output 1 on the J7 connector as shown in Figure
3-25.
TO AUX POWER +
TERMINAL 6
10mA CURRENT DRAIN)
RED
J7_trigcon-001-V1
Figu r e 3-25: Rem ote Keypa d Sou n d er Wir in g
Long Range Radio Connected to the J7 Triggers
These triggers may be used to trip auxiliary alarm
signaling equipment such as the 7720, 7720ULF, and
7920SE Long Range Radios.
The fire and burglary/audible panic alarm triggers are
normally LOW and go HIGH until a User Code + OFF
is entered in all enabled partition(s) that display these
conditions.
The triggers are common to all partitions and must be
The silent panic/duress trigger latches HIGH, except for
duress, which is momentary.
enabled for each partition (field 2✳20).
Refer to the installation instructions that accompany
your radio for the connections to the control panel.
Installing a 4100SM
The 4100SM is used to print event log reports to a
serial printer.
NOTE: See SECTION 4: Programming for the
programming details when using the 4100SM.
Printer Configurations
Configure the serial printer as follows:
•
•
•
8 data bits, no parity, 1 stop bit
1200 baud
Hardware handshaking using DTR.
3-19
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Connecting the 4100SM to a Serial Printer
1
2
3
4
5
6
7
8
9
J8 CONNECTOR
NU
To connect a serial printer using the 4100SM, refer to
Figure 3-26 and perform the following steps:
Action
Step
OUND
IN
2
IN
3
OUND
GR
OUND
OUT
5
OUT
6
GR
GR
Connect terminal 1 on the 4100SM to the
Violet wire on the 4142TR cable.
1
4142TR CABLE (SUPPLIED WITH 4100SM)
4100SM SERIAL MODULE
To TB6 Aux. Power (+)
(25mA current draw)
Connect terminal 6 on the 4100SM to the
Brown wire on the 4142TR cable.
2
3
4
8
7
6
5
4
3
2
1
+ PWR
- (GND)
RXD
To TB7 Aux. Power (-)
Connect the 4142TR cable to J8 on the
control.
not used
not used
TXD
Connect terminals 8 and 7 of the 4100SM to
terminals 6 and 7 (aux. power (+) and (-)),
respectively of the control.
not used
DTR
RED
BLUE WHITE
Connect the UL EDP Listed serial printer to
the 4100SM Interface Module.
5
3M
Cable
USE GENDER CHANGER
SUPPLIED WITH 4100SM
IF PRINTER HAS DB25
MALE CONNECTOR
Supplied with
4100SM
The 4100SM Module is supplied with a 10-
foot RS232 cable. A longer cable can be used
if the VISTA-40 is separated from the serial
printer by more than 10 feet, but the total
cable length should be less than 50 feet.
4100SM JUMPERS
(CUT TO SET RESPECTIVE SIGNAL FLOATING)
COLOR
FUNCTION
PIN #
SERIAL PRINTER
SET FOR: 8 DATA BITS
EVEN PARITY
RED
BLUE
WHITE
CD
CTS
DSR
8
5
6
STOP BIT
300/1200 BAUD
Figu r e 3-26: 4100SM Usin g a Ser ia l P r in ter
NOTE: See the 4100SM Installation Instructions for
details concerning the serial printer operation.
Installing the 4285/4286 VIP Module
The 4285/4286 VIP Module is an add-on accessory that
permits the user to access the security system (and
relays) via a TouchTone telephone. This may be done
either from the premises or by calling the premises from
a remote location. Only one VIP Module can be used in
a security system. This module must be enabled as
Device Address 4 in the Device Programming in #93
Menu Mode, and must be assigned to a partition.
The 4285/4286 VIP Module features:
•
Allows the user to receive synthesized voice
messages over the phone regarding the status of
the security system.
•
Allows the user to arm and disarm the security
system and perform most other commands using
the telephone keypad.
•
•
•
Allows the user to control relays using the
telephone keypad.
The 4285/4286 VIP Module is not permitted in
UL installations.
U
L
Provides voice annunciation over the phone to
confirm any command that is entered.
Announces many of the same words that would
normally be displayed on an alpha keypad under
the same system conditions. Refer to the words in
bold on the Alpha Vocabulary list found in the #93
Menu Mode in the Programming Guide.
Detailed operating instructions for phone access
to the security system are provided with the VIP
Module.
The 4285/4286 is wired between the control panel and
the premises’ handset(s) (see Figure 3-27). It listens for
TouchTones on the phone line and reports them to the
control panel. During on-premises phone access, it
powers the premises phones. During off-premises phone
access, it seizes the line from the premises phones and
any answering machines.
•
Can be supervised for connection to control panel
(annunciated and reported as Zone 804).
• The VIP module will not operate until the
device address (04) is enabled in the control’s
Device Programming in #93 Menu Mode.
• Do not mount the VIP Module on the cabinet
door or attempt to attach it to the PC board.
3-20
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
To install the VIP module, perform the following steps:
Step
Action
Step
Action
1
Mount the module in the control cabinet if
space is available or, if this is not possible, on
the side of the cabinet or adjacent to it.
4
Connect the module to the phone line as
shown below. See Figure 3-27.
4285/4286 Terminal
Connects to direct
connect cord:
If you mount the VIP Module inside the
control cabinet, attach it to the cabinet’s
interior surface with 2-faced adhesive tape.
You may leave the module’s cover off if it is
mounted within the cabinet.
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5. No Connection
6. Audio Out 1∗
green wire
red wire
brown wire
gray wire
If you mount the module outside the
cabinet, use the screw holes at the rear to
mount horizontally or vertically (2-faced
adhesive tape may be used, if preferred).
Speaker
Speaker
7. Audio Out 1∗
Supported by the 4286 only
2
3
Affix the 4285/4286 connections label
(supplied separately) to the inside of the VIP
Module’s cover, if the cover is used.
Otherwise, affix the label to the inside of the
control cabinet’s door.
Use an RJ31X Jack with the phone cable
supplied with the control to make connections
to the VIP module. Make connections exactly
as shown in Figure 3-27. This is essential,
even if the system is not connected to a
central station. The 4285/4286 will not
function if this is not done.
Make 12V (+) and (–) and data-in and data-
out connections from the VIP Module to the
control, using the connector cable supplied
with the VIP Module. These are the same
connections as for remote keypads.
• If touch-tones are not present following phone
access to the security system via an on-
premises phone, try reversing the pair of
wires connected to terminals 3 and 4 on the
4285/4286.
• If the phone plug is disconnected from the
control, the premise’s phones will not operate.
SPEAKER NOTE: IF CONNECTING SINGLE SPEAKER, USE 8-ohm SPEAKER ONLY.
IF CONNECTING 2 SPEAKERS, USE 4-ohm or 8-ohm SPEAKERS
AND CONNECT IN SERIES.
INCOMING TELCO LINE
SEE SPEAKER NOTE
4286 VIP MODULE
NOTE:
GREY
BROWN
TIP
RING
RJ31X
JACK
4286 DEVICE
ADDRESS IS
FACTORY SET
TO “4”
SPEAKER
VOLUME
CONTROL
PREMISES
ANSWERING
MACHINE AND
PHONES
CALLER ID
UNIT
NO
CONNECTION
KEYED
HEADER
ANSWERING
MACHINE
EARTH
GROUND
TO CONTROL PANEL
KEYPAD CONNECTIONS
TIP RING TIP RING
HANDSET INCOMING
TELCO LINE
YELLOW
GREEN
4500
YELLOW
THERMOSTAT
NO CONNECTION
RED
BLACK
GREEN
IMPORTANT NOTE FOR EXISTING INSTALLATIONS:
EXISTING WIRES CONNECTED TO THE “HANDSET”
TERMINALS ON CONTROL MUST BE MOVED FROM
THERE TO TERMINALS 3 AND 4 ON THE 4286.
THIS DEVICE COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION No. AC3USA-74659-KX-N
RINGER EQUIVALENCE: 1.0B
U.S. PATENT No. 4791658
FOR COMPLETE INFORMATION, SEE INSTALLATION
INSTRUCTIONS N6431-3 ACCOMPANYING 4286 VIP
MODULE
4286_wiring-002-V1
Figu r e 3-27: VIP Mod u le Con n ection s
3-21
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Installing the Audio Alarm Verification Module
Audio Alarm Verification (AAV) is not permitted
in UL installations.
If the phone plug is disconnected from the
control, the premise’s phones will not operate.
U
L
NOTES:
•
•
•
685 Receiver software must be rev. 4.6 or
higher. Earlier versions will not hold the
phone line connection.
•
•
•
When the AAV indicates that the audio alarm
verification session is completed, all keypad sounds
are restored. Sirens are restored if the alarm
timeout period has not expired.
As part of its fail-safe software, the control limits
all audio alarm verification sessions to 15 minutes.
This is because once the session begins, the AAV
Module controls the duration.
If a new Fire alarm should occur during a session,
the control breaks the phone connection and sends
the new Fire Alarm report, then re-triggers the
AAV Mode. All other dialer messages triggered
during ongoing conversation are held until either
the AAV Module signals that it is inactive, or the
15-minute timeout occurs.
Contact ID code for “Listen-in to Follow” is
606. Contact ID is the only reporting format
that will send a “Listen-in to Follow.”
If you are also using a 4285/4286 VIP
Module, be sure to follow Figure 3-30 when
making connections.
The UVS consists of a UVCM and at least one UVST.
The UVCM board has a DC power jack and a 34-
position terminal block for making connections to a DC
power source, UVSTs, telephone lines, music source, or
to the 4286 VIP Module; and to a control panel’s voice
trigger and bell outputs (if required). Refer Figure 3-28
for wiring connections. For a detailed explanation of
the wiring connections and the functions of the DC
power jack and terminal block positions, refer to the
installation instructions that accompany the UVS.
3-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
UVCM AND UVST SUMMARY OF CONNECTIONS
Refer to UVS Installation and Setup Guide K4214 for complete information
SW
SWITCH BANK 2
NOTE 1: CONNECT TO PROPER EARTH GROUND.
SW
SWITCH BANK 1
NOTE 2: POWER MAY ALSO BE SUPPLIED BY A LISTED CLASS 2
POWER SUPPLY RATED 12VDC, MIN 600mA CONNECTED TO THE
UVCM +12VDC IN AND GND TERMINALS.
1
2
3
4
5
6
7
8
FUTURE USE, SET TO ON
FUTURE USE, SET TO ON
1
2
3
4
5
6
7
8
UVST 1 AUX AUDIO, ON = ENABLED
UVST 2 AUX AUDIO, ON = ENABLED
UVST 3 AUX AUDIO, ON = ENABLED
UVST 4 AUX AUDIO, ON = ENABLED
UVST 5 AUX AUDIO, ON = ENABLED
UVST 6, ON = OUTSIDE, OFF = INSIDE
UVST 7, ON = OUTSIDE, OFF = INSIDE
VOICE TRIGGER, ON = IMMED, OFF = CALLBACK
TELEPHONE RING, ON = ENABLED
END USER VOICE, ON = DISABLED
FUTURE USE, SET TO ON
CS CODE LEARN, ON = DISABLED
USER CODE LEARN, ON = DISABLED
FUTURE USE, SET TO ON
NOTE 3: SOME CONTROL PANELS USE BUILT-IN TRIGGER AND SOME
USE 4204 RELAY MODULE. REFER TO AAV SECTION OF CONTROL PANEL
INSTALLATION AND SETUP GUIDE FOR CONNECTION.
NOTE 4: EITHER MUSIC SOURCE OR 4286 VIP MODULE CAN BE USED BUT
NOT AT THE SAME TIME.
NOTE 5: DO NOT CONNECT IF 4286 VIP MODULE IS USED.
SHIPPED WITH ALL SWITCHES IN "ON" POSITION.
ON
1
ON
1
2
3
4
5
6
7
8
2
3
4
5
6
7
8
SWITCH BANK 1
SWITCH BANK 2
ALTERNATE
+12 VDC IN FOR
PLUG-IN WALL PACK
(SEE NOTE 2)
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
NOTE 1
MUSIC SOURCE
OPTIONAL
(NOTE 4)
AUDIO OUT
GND
TIP
RJ31X
JACK
INCOMING
TELCO
LINES
PLUG
CONTROL PANEL
RING
DIRECT
CONNECT
CORD
INCOMING RING
INCOMING TIP
HANDSET RING
HANDSET TIP
SPEAKER
VOLUME
CONTROL
SPEAKER
VOLUME
TRIM POT
VOLUME CONTROL DIAL
4286 VIP
MODULE
OPTIONAL
(NOTE 4)
UVST
P3
P7
KEYED
HEADER
ANSWERING
MACHINE
P2
TYPICAL 1 OF 7
P1
FOR COMPLETE INFORMATION, SEE
4286 VIP MODULE INSTRUCTIONS.
COMPLIES WITH FCC RULES, PART 68
FCC REGISTRATION NO. AC3 USA-40133-SP-T
RINGER EQUIVALENCE: 1.0B
PREMISES
ANSWERING
MACHINE AND
PHONE (S)
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
WARNING: TO PREVENT RISK
OF ELECTRICAL SHOCK,
DISCONNECT TELCO JACK
BEFORE SERVICING THIS PANEL.
Figu r e 3-28: UVS Con n ection s to th e Con tr ol P a n el
Connecting the Transformer
This product uses the 1361 transformer (1361CN in
Canada). If you are using X-10 devices, the 1361X10
transformer interface must be used in stea d of the
regular 1361 transformer. The 1361X10 supplies the
control panel with AC, and also sends control pulses
through the premises electrical system to control the X-
10 devices.
Use 1361CN Transformer in Canadian
installations.
U
L
3-23
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Power Limiting Outputs
Failure to observe the polling loop current
rating will cause polling loop malfunction.
Failure to observe the auxiliary power current
rating will result in a battery that does not
charge properly or possibly a tripped circuit
breaker.
All outputs are power-limited as per UL985/UL1023.
The following table shows the maximum current that
may be drawn from each output.
Output
Maximum Current Draw
Auxiliary Power
Polling Loop
Alarm Output
750mA
64mA
1.7A
To connect the transformer to the control, perform the
following steps:
Step
Action
For Household Fire or Combination Household
Fire/Burglary Installation: The total current drawn
from the auxiliary power, the polling loop, and the
alarm output combined must not exceed 750mA to
comply with the battery independence requirements in
UL985.
1
2
Connect all installed devices to the control.
Wire the 1361 Transformer (1361CN in
Canada) to the panel (before connecting the
battery) as shown in Figure 3-29, or wire the
1361X10 Transformer as shown in Figure 3-
30 (if using X-10 devices).
For Household Burglary-Only Installations: The
total current drawn from the alarm output may be up to
1.7A. A battery must be installed to supply the current
of the combined auxiliary power, polling loop, and
alarm output in excess of 750mA.
3
Plug the transformer into a 24-hour,
uninterrupted, 120VAC, 60Hz outlet. After
a few seconds, the keypad display appears.
BATTERY
TABS
PRIMARY POWER
Connect to
12VDC, 4AH
or 12VDC, 7AH
Supplied by a transformer
which is rated at
16.5VAC, 40VA.
Caution must be taken when
wiring this transformer to the
panel to guard against blowing
the fuse inside the transformer
(non-replaceable).
1
2
3
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7VDC
Connect to
24hr. source
of AC mains
TRANSFORMER
16.5VAC, 40VA
NOTE:
WHEN POWERING UP
THE PANEL, PLUG THE
TRANSFORMER IN BEFORE
CONNECTING THE BATTERY.
ADEMCO No.1361
or 1361X10, if X-10
DEVICES WILL BE USED.
Figu r e 3-29: 1361 Tr a n sfor m er a n d Ba tter y Con n ection s
X10 TRANSFORMER/INTERFACE
1
2
3
4
5
6
7
8
9
J8 CONNECTOR
4142TR CABLE
TERMINALS
ON CONTROL
BOARD
1361X10-001-V0
Figu r e 3-30: 1361X10 Tr a n sfor m er Con n ection s
3-24
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
Panel Earth Ground Connections
In order for the lightning transient protective devices in
this product to be effective, the designated earth ground
terminal (terminal 30) must be terminated in a good
earth ground. Recommended wire gauge for the ground
connection is #16 AWG, run no farther than 30 feet.
The following are examples of good earth grounds
available at most installations:
•
AC Power Outlet Ground: Available from 3-
prong, 120VAC, power outlets only. To test the
integrity of the ground terminal, use a three-wire
circuit tester with neon lamp indicators, such as
the UL-Listed Ideal Model 61-035, or equivalent,
available at most electrical supply stores.
The panel requires the earth ground
connection for its lightning transient protection
devices.
•
Metal Cold Water Pipe: Use a noncorrosive metal
strap (copper is recommended) firmly secured to the
pipe to which the ground lead is electrically
connected and secured.
Determining the Control’s Power Supply Load
Use the tables that follow to calculate the total current
for the Auxiliary Power, the Alarm Output, and the
Polling Loop. In each table, multiply each device’s
standby and/or alarm current by the number of units
used.
2. In Table 2, enter devices used on Auxiliary Power.
Calculate standby and alarm currents, then add to
get Auxiliary Power current subtotal.
Table 2: Auxiliary Power Current Load
1. In Table 1, enter devices used on the polling loop.
Calculate total current draw on the polling loop.
Total Current
Device
Model #
Device Current X
# of Units
Standby
Alarm
Table 1: Total Polling Loop Current Draw
Polling Loop Device Current # of Units
Total
Auxiliary Power Subtotal
(terminals 6 & 7 – 750mA max.)
Polling Loop Subtotal
(terminals 24 & 25 – 64mA) ✳
✳ The total current cannot exceed 64mA. If total load exceeds
64mA, then a 4297 Loop Extender Module can be used. Note
that the total number of points connected to the panel cannot
exceed 55.
3-25
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
3. In Table 3, enter devices connected to the Alarm
Output. Calculate alarm currents, then add to get
the Alarm Output current subtotal.
4. In Table 4, enter the total calculated subtotals of
all listed outputs from Tables 1 through 3, then add
to get the combined current.
Table 3: Alarm Output Current Load
Table 4: Total VISTA-40 Current Load
Total Current
Total Current
Device
Model # # of Units
Device Current X
Standby
Alarm
Standby Alarm
Polling Loop Subtotal (see Table 1)
Aux. Power Subtotal (see Table 2)
Alarm Output Subtotal (see Table 3)
XXXXXX
XXXXXX
XXXXXX
XXXXXX
XXXXXX
XXXXXX
XXXXXX
VISTA-40 PCB Current (Includes 2-
wire smoke detector loading on
250mA
330mA
zone 1)
Total Current Load
Alarm Output Subtotal
(terminals 4 & 5 – 1.7A max.)
Determining the Size of the Standby Battery
The cabinet supplied with the control panel can house
batteries of up to 12V, 14AH (two 12V, 7AH batteries
wired in parallel). The VISTA-ULKT kit provides a
cabinet that can house batteries of up to 12V, 17.2AH
and that may be used with this panel. The total
standby current drawn from the auxiliary power and
polling loop outputs combined must be limited to
270mA when 14AH batteries are used; and to 390mA
when 17.2AH batteries are used.
Use Table 5 to determine the required backup battery
capacity and use Table 6 to determine the battery
model number. A dual battery harness is supplied
that allows two batteries to be wired in parallel for
increased capacity.
5. Using the total calculated from Table 4, calculate
the battery capacity required for the installation.
Table 5: Battery Capacity Calculation Table
Calculated
Value
Capacity Formula
DO NOT use Gates batteries (sealed lead-acid
type). These batteries require a different
charging voltage than is supplied by the panel.
Standby
Capacity
For 4-hour standby time:
Total standby current X 4 hours
X 1.4 contingency factor.
Household Fire or Combination
For 24-hour standby time:
Total standby current X 24
hours X 1.1 contingency factor.
U
L
Household/Fire/Burglary installations require
the use of a backup battery that is capable of
providing 24 hours of standby time followed by
4 minutes of alarm time. UL1023 Household
Burglary-only installations require the use of a
backup battery that is capable of providing 4
hours of standby time followed by 4 minutes of
alarm time.
Alarm
Capacity
For 4-, 5-, or 15-minute alarm
time:
Total alarm curr.
X 0.067 (4 min)
X 0.250 (15 min)
Total
Add standby and alarm
Capacity capacities
3-26
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3 - Installing the Control
6. Use the Battery Selection Table to select the
appropriate battery for the installation.
7. Connect the battery, referring to Figure 3-29.
Table 6: Battery Selection Table
The standby battery is automatically tested for
10 minutes every 4 hours, beginning 4 hours
after exiting Programming mode. In addition,
entry into the Test mode initiates a battery test.
Capacity Recommended Battery
Comment
4AH
7AH
12AH
Yuasa NP4-12
Yuasa NP7-12
Yuasa NP12-12
Fits in large
mercantile
cabinet only.
14AH
Yuasa NP7-12
Connect two
in parallel.
17.2AH
Yuasa NPG18-12
Fits in large
mercantile
cabinet only.
3-27
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
3-28
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
4
Programming
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Program Modes
The factory-loaded defaults (✳97) enable
keypad addresses 00-03 only. A keypad set to
one of these addresses must be used to
program the system initially.
There are two programming modes for the VISTA-40.
These are the Data Field Program Mode and the #93
Menu Mode. The Data Field Program Mode is where
many system options are programmed. The #93 Menu
Mode is an interactive mode that requires a 2-line
alpha keypad (6139/6160).
Local keypad programming can be disabled
through Compass downloading software. If
this is done, Program mode can only be
accessed via the downloading software.
Entering and Exiting Programming Mode
Enter Programming mode using either method a or b:
Exit the Programming mode by either method a or b:
a. Press [✳] + [9] + [8]. Exiting by this method
prevents the installer code from being used to re-
enter Programming mode. Only method “a” can be
used to re-enter Programming mode.
a. Press both the [✳] and [#] keys at the same time
within 30 seconds after power is applied to the
control.
b. Enter the Installer Code + [8] + [0] + [0] keys.
The factory installer code can be changed once in
the Program mode (field ✳00).
b. Press [✳] + [9] + [9]. Exiting by this method
permits the installer code to be being used to re-
enter Programming mode.
NOTE: The default for the Installer Code is 4140.
Data Field Programming Mode
In the Data Field Program Mode you may access any
field simply by entering either [✳] or [#] + the field
number:
Moving Between Programming Levels
The data fields are grouped into three levels (referred to
as “pages”). The first page is accessed as soon as
Programming Mode is entered.
•
To write or change information in a field press [✳]
+ the field number (✳03).
The second and third pages of data fields are indicated
at the keypad by a 1 and 2, respectively, in front of the
2-digit field address. “ALT PROGRAM MODE” is
displayed along with a “100” or “200,” indicating which
page of program fields is accessed.
•
To read the information in a field press [#] + the
field number (#03).
When the entries for a field are completed, the keypad
beeps three times and advances to the next field.
To access the next level of programming fields, perform
the following steps:
Summary of Data Field Programming Commands
Step
Action
Select partition for programming partition-specific fields
Display the software revision level of the control panel
Enter Menu mode programming
✳91
✳92
✳93
✳94
✳99
1
2
Press ✳94.
Press [7] + [XX], where XX = the last two
digits of the program field, and make the
desired entry.
Go to next page of fields
NOTES:
Go back to previous page of fields or exit
Programming Mode with no installer code lockout
Press ✳94 to move to 2nd page, (fields 1✳01 - 1✳76);
press ✳99 to move back to 1st page.
Exit Programming Mode with Installer Code lockout
✳98
Press ✳94 to move to 3rd page (fields 2✳00 - 2✳21); press
✳99 to move back to 2nd page
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
NOTE: If the number of digits that you enter in a data
field is fewer than the maximum permitted (for
example, a phone number), the keypad displays the last
entry and waits. To proceed, enter [✳] + the next data
field you wish to program.
Entry Errors
•
If an address is improperly entered, the keypad
displays “FC.”
•
If a program entry is improperly entered (for
example, a larger number than is permitted), the
keypad display will go blank.
Programming Partition-Specific Data Fields
In either of the above cases, simply re-enter [✳] + the
correct field number and then enter the correct data.
To program partition-specific data fields once in
Program Mode, do the following:
Step
Action
Programming System-Wide Data Fields
1
Enter Program Mode: Installer Code + 8 0
0.
Values for some programming fields are system-wide
(global), and some can be different for each partition
(partition-specific).
2
3
Press ✳91, which will prompt you for the
partition number desired.
The partition-specific programming fields are
automatically skipped when programming the
global fields. If the system has only 1 partition,
the partition-specific fields are not automatically
skipped.
Enter a partition-specific field number (e.g.,
✳09) to begin programming.
When the first field’s entry is completed, the
next partition-specific field is automatically
displayed. When all partition-specific fields
are programmed, the system returns to the
global programming fields (page 1 fields).
To program system-wide data fields, perform the
following steps:
Step
Action
4
Repeat this procedure for the other partition.
1
Enter Program Mode: Installer Code + 8 0 0.
The following display appears:
NOTE: To return to the global program fields before
finishing all fields, enter any global field number.
Programming Partition-Specific Fields
Program Mode
Press ✳91 to select a partition.
✳Fill # View – 00
p
Enter the partition to be programmed.
2
3
If the control has not been programmed before,
enter ✳97 to load factory defaults.
p
Enter a partition-specific field number and make
entry.
Press [✳] and enter the first field number to be
programmed (for example, ✳00, Installers
Code). Make the desired entry. When the field
is complete, the keypad beeps three times and
advances to the next field. If you do not want to
change the next field, press [✳] and enter the
next field number to be programmed.
p
Enter any global field number to return to the global
fields at any time.
First Page of fields
(✳00 - ✳90)
To change to the next page of fields, press ✳94.
To return to the previous page of fields, press
✳99.
4
Press ✳99 or ✳98 to exit Program Mode.
#93 Menu Mode Programming
The #93 Menu Mode is an interactive mode through
which much of the system’s programming is done. In
this mode, there are “question and answer” prompts
that can be accessed once Data Field Program Mode has
been entered. These prompts require a 2-line alpha
keypad (6139/6160).
After programming all system-related programming
fields in the usual way, press #93 while still in
programming mode to display the first choice of the
menu-driven programming functions. Press 0 (NO) or 1
(YES) in response to the displayed menu selection.
Pressing 0 will display the next choice in sequence.
4-2
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Below is a list of the main menus. For details refer to the VISTA-40 Programming Guide.
MAIN MENU
OPTIONS
For programming the following:
ZONE PROG?
•
Zone Number
1 = YES 0 = NO
0
•
•
•
•
•
Zone Response Type
Partition Number for Zone
Dialer report code for zone
Input Device Type for zone (whether RF, polling loop, etc.)
Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.
Same as Zone Programming except:
EXPERT MODE?
1 = YES 0 = NO
•
Done with a minimum number of keystrokes.
0
0
•
Can program wireless keys using pre-defined templates.
For entering alpha descriptors for the following:
ALPHA PROG?
1 = YES 0 = NO
•
Zone Descriptors
Installer’s Message
Custom Words
•
•
•
•
Partition Descriptors
Relay Descriptors
For defining the following device characteristics for addressable devices, including keypads, RF
receivers (5881), relay modules (4204), and 4285/4286 VIP Module:
DEVICE PROG?
1 = YES 0 = NO
0
•
Device Address
•
•
•
Device Type
Keypad Options (including Partition assignment)
RF House ID
For defining relay device functions.
RELAY PGM?
1 = YES 0 = NO
0
0
0
For entering voice descriptors for relays to be used with the 4285/4286 VIP Module.
For creating custom word substitutes for VIP Module annunciation.
RLY VOICE DESCR?
1 = YES 0 = NO
CUSTOM INDEX ?
1 = YES 0 = NO
Following is a list of commands used while in the Menu Mode:
#93 Menu Mode Programming Commands
#93
Enters Menu Mode.
Serves as [ENTER] key. Press to have keypad accept entry.
[✳]
[#]
Backs up to previous screen.
0
Press to answer NO.
1
Press to answer YES.
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option.
00, or 000+[✳]
4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Zone Number Designations
The VISTA-40 supports up to 64 zones of hardwire,
polling loop and/or wireless protection, distributed
among up to 2 partitions. The following table lists the
zone numbers and the types of sensors that can be used
with each, and some alternate functions of the zones.
Zone Index
The zones are designated as follows:
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
As indicated
01 – 64
Protection
zones
Zone
1
Function
2-wire Smoke Detectors (if used)
Audio Alarm Verification (if used)
Keyswitch (if used)
70, 88, 89, System
90, 91, &
97
70:
88:
Bell Supervision
2nd Wireless Receiver –
Supervisory
Zones
5
not receiving signals
7
89:
90:
91:
97:
2nd Wireless Receiver –
not talking to control
1st Wireless Receiver –
not receiving signals
1st Wireless Receiver –
not talking to control
8
Latching-Type Glassbreak Detectors (if used)
Traditional Hardwired Zones
5800 Series Wireless Devices
Polling Loop Devices
✳ + 1 Panic
1-9
1-64
10-64
95
Polling Loop (short
circuit)
96
# + 3 Panic
99
✳ + # Panic
92, 95, 96, Duress and
& 99 Keypad Panics
92:
95:
96:
99:
Duress
Zone Defaults
1 + ✳ panic (A key)
3 + # panic (C key)
✳ + # panic (B key)
Zone #
Zone Type
Zone #
70
Zone Type
01
09
03
03
03
03
03
03
03
03
00
00
00
00
00
00
N/A
00
00
05
06
02
87
Supervisory zones should be given a response type of 05
(Trouble by Day, Alarm by Night).
03
88
04
90
05
91
06
92*
95
07
08
96
09
97
10–64
99
NOTES: *Zone 92 is the Duress zone. Programming of the
zone response type is not applicable. This zone requires only
the report code programming.
Communication Defaults
*45 PRIMARY FORMAT
*46 LOW SPEED FORMAT (Prim) [0] ADEMCO Low Speed
*47 SECONDARY FORMAT [1] ADEMCO Contact ID
*48 LOW SPEED FORMAT (Sec.) [0] ADEMCO Low Speed
*49 CHECKSUM VERIFICATION [0] [0]
[1] ADEMCO Contact ID
*51 DUAL REPORTING
*52 STANDARD/EXPANDED REPORT FOR PRIMARY
[0] [0] [0] [0] [0] [0]
[0] no
standard
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
*53 STANDARD/EXPANDED REPORT FOR SECONDARY
[0] [0] [0] [0] [0] [0]
standard
No checksum
Primary Secondary
Alarm Rstr Bypass Trbl Opn/Cls Low Bat
*50 SESCOA/RADIONICS SEL.
[0] Radionics
4-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4 – Programming
Communication Defaults for Zones
ZONE #
1st
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
01
02
03
04
05
2nd
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
ZONE #
21
1st
06
07
08
09
10
11
12
13
14
15
01
02
03
04
05
16
17
18
19
10
2nd
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
ZONE #
41
1st
11
12
13
14
15
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
2nd
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
ZONE #
61
62
63
64
70
88
89
90
1st
01
02
02
04
00
00
00
00
00
11
00
00
06
06
00
00
00
00
00
2nd
00
00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
91
92 (DURESS)
95
96
97
99
ALARM RST.
TROUBLE
TRBLE. RST
BYPASS
BYP. RST.
38
39
40
58
59
60
Zone Response Type Definitions
Each zone must be assigned a zone type, which defines
the way in which the system responds to faults in that
zone. There are three keypad-activated zones (panic
keys; see note) for each partition, a polling loop
supervision zone, and four RF supervisory zones, two
for each RF receiver installed. Zone types are defined
below.
Type 03: Perimeter Burglary
Provides an instant alarm if the zone is faulted and the
system is armed in the AWAY, STAY, INSTANT, or
MAXIMUM mode.
Assign this zone type to all exterior door and window
zones.
Type 04: Interior, Follower
Type 00: Zone Not Used
Provides a delayed alarm (using the programmed entry
delay time) if an entry/exit zone is faulted first.
Otherwise it produces an instant alarm. It is active
when the system is armed in the AWAY or MAXIMUM
mode, but the MAXIMUM mode eliminates the entry
delay.
Program with this zone type if the zone is not used.
Type 01: Entry/Exit #1 Burglary
Provides entry delay whenever the zone is faulted and
the system is armed in the AWAY or STAY mode. When
the panel is armed in the INSTANT or MAXIMUM
mode, no entry delay is provided. Exit delay begins
whenever the control is armed, regardless of the arming
mode selected. These delays are programmable.
Zones programmed for Interior Follower zone are
automatically bypassed when the panel is armed in the
STAY or INSTANT mode.
Assign this zone type to zones that are used for primary
entry to and exit from the facility.
Assign this zone type to a zone covering an area such as
a foyer, lobby, or hallway through which one must pass
upon entry or exit (to and from the keypad).
Type 02: Entry/Exit #2 Burglary
Type 05: Trouble by Day/Alarm by Night
Provides a secondary entry delay, if the system is
armed in the AWAY or STAY modes and the zone is
faulted. When the panel is armed in the INSTANT or
MAXIMUM mode, no entry delay is provided.
Secondary exit delay begins whenever the control is
armed, regardless of the arming mode selected. These
delays are programmable.
Provides an instant alarm if the zone is faulted and the
system is armed in the AWAY, STAY, INSTANT, or
MAXIMUM mode. During the disarmed state (day), the
system annunciates a latched trouble sounding from
the keypad (and a central station report, if desired).
Assign this zone type to a zone that contains a foil-
protected door or window (such as in a store), or to a
zone covering a sensitive area such as a stock room or
drug supply room. It can also be used on a zone in an
area where immediate notification of an entry is
desired.
Assign this zone type to zones that are used for entry
and exit of the facility and require more time than the
primary entry and exit point. Delay times for this zone
type must be greater than those for zone type 01 (e.g., a
garage, loading dock, or basement door).
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Type 06: 24-Hour Silent Alarm
Type 20: Arm-STAY (5800 Series devices only)
Sends a report to the central station but provides no
keypad display or sounding. Assign this zone type to a
zone containing an Emergency button.
Causes the system to arm in the STAY mode when the
zone is activated.
Type 21: Arm-AWAY (5800 Series devices only)
Type 07: 24-Hour Audible Alarm
Causes the system to arm in the AWAY mode when the
zone is activated.
Sends a report to the central station and provides an
alarm sound at the keypad and an audible external
alarm. Assign this zone type to a zone containing an
Emergency button.
Type 22: Disarm (5800 Series devices only)
Causes the system to disarm when the zone is
activated.
Type 08: 24-Hour Auxiliary Alarm
Type 23: No Alarm Response
Sends a report to central station and provides an alarm
sound at the keypad only. (No bell output is
provided.) Assign this zone type to a zone an
Emergency button or one containing monitoring devices
such as water sensors or temperature sensors.
Used on a zone when an output relay action is desired,
but with no accompanying alarm (e.g., for access door).
NOTE FOR PANIC KEYS: Keypad panic zones share the same
zone response type for both partitions, but panics may be
individually enabled for each partition.
Type 09: Supervised Fire (Without Verification)
Provides a fire alarm on a short circuit and a trouble
condition on open circuit. A fire alarm produces a
pulsing of the bell output. A zone of this type is always
active and cannot be bypassed.
IMPORTANT! FAULT ANNUNCIATION
Polling loop and RF troubles (zones 88, 89, 90, 91, and 97) report
as trouble conditions only, and as such, should be assigned zone
type 05 if annunciation is desired. See Polling Loop Supervision
and RF System Operation and Supervision in SECTION 3
Installing the Control for more information.
Type 10: Interior with Delay
Provides entry and exit delays (using the programmed
entry and exit delay times) when armed in the AWAY
mode. Provides only exit delay when armed in the
MAXIMUM mode (no entry delay). Delay begins
whenever sensors in this zone are violated, regardless of
whether or not an entry/exit delay zone was tripped
first.
Zones programmed for Interior with Delay are
automatically bypassed when the panel is armed in the
STAY or INSTANT mode.
Assign this zone type to a zone covering an area such as
a foyer, lobby, or hallway through which one must pass
upon entry or exit (to and from the keypad).
Zone Input Type Definitions
Each zone must be assigned an input type, which
defines the where the system will “look” for status of the
zone (RF receiver, polling loop, etc.). Zone input types
are defined below.
Type 05 Unsupervised Button RF (BR)
Select for 5800 Series RF transmitters specifically
designed for this input type. Check the transmitter’s
instructions for proper programming of the input type.
These transmitters send only fault signals. They do not
send low-battery signals until they are activated. The
transmitter may be carried off-premises.
Type 01 Hardwired (HW)
Reserved for the built-in hardwired zones 1-9.
Type 03 Supervised RF (RF)
Type 06 Serial Number Polling Loop (SL)
Select for 5800 Series RF transmitters that will be
supervised for check-in signals. The transmitter must
remain within the receiver’s range.
Select for polling loop devices with a built-in serial
number.
Type 07 DIP Switch Loop (DP)
Type 04 Unsupervised RF (UR)
Select for polling loop devices that use DIP switches for
programming the zone number of the device.
Select for 5800 Series RF transmitters that will not be
supervised for check-in signals. The transmitter may
therefore be carried off-premises.
Type 08 Dip Switch Polling Loop Right Loop (PS)
Select for the second loop of two-zone polling loop
devices (e.g., 4190WH; 4278).
4-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4 – Programming
Programming for 4100SM
•
•
•
1✳40 & 1✳41 Date and Time Set Report Codes
1✳70 Event Log Types (1=enable; 0=disable
1✳71 12/24-Hour Time Stamp (0=12 hr; 1=24 hr)
Programming for Access Control
A user can trigger an access point (i.e., door strike) for 2
seconds by entering User Code + [0].
To program the VISTA-40 for access control, perform
the following steps:
Step
Action
1
Enter Relay Programming in the #93 Menu
Mode.
2
3
Program the relay type as 1, or 2.
For type 1, program the ECP address and
relay number.
4
5
For type 2, program the house and unit codes.
Program the relay number in field 1∗76
(partition-specific).
See Relay Programming in the Programming Guide for
a detailed explanation.
4-7
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
4-8
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
5
Data Field Descriptions
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Data Field Programming
The following pages list this control’s data fields in numerical order. Field numbers are listed in the left column, followed
by a “Title and Data Entries column, which lists the valid entries for each field. Experienced installers can simply follow
this column when programming the data fields. The “Explanation” column provides explanatory information and special
notes where applicable.
NOTE: Refer to the Programming Guide for the default values. They are not listed in this section.
Use the Programming Guide to record the data for this installation.
Programming Data Fields
Data field programming involves making the appropriate entries for each of the data fields. Start Data Field
programming by entering the installer code + 8 + 0 + 0.
FIELD
TITLE and DATA ENTRIES
EXPLANATION
The Installer Code is a 4-digit code reserved for installation company use.
Installer Code
Enter 4 digits, 0-9
*00
This is the only code that can be used to enter the Program Mode from
the keypad. This code cannot be used to disarm the system if it isn’t used
to arm the system. This code cannot be used to re-enter Program Mode if
Program Mode is exited by the *98 command.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Response Types for Zones 01–08
Response Types for Zones 09–16
Response Types for Zones 17–24
*02
*03
*04
*05
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Response Types for Zones 25–
27, 97, 95, 96, and 99
Entry delay defines the delay time that allows users to re-enter the
premises through a door that has been programmed as an entry delay
door and disarm the system without sounding an alarm. The system must
be disarmed within this period or an alarm will occur.
Entry Delay #1 (partition-specific)
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
*09
NOTE: The delay may not exceed 45 seconds for UL installations.
Exit delay defines the delay period that allows users to leave the premises
through a door that has been programmed as an entry/exit delay door
after arming the system without setting off the alarm.
Exit Delay #1 (partition-specific)
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
*10
*11
Entry Delay #2 is used for a secondary door requiring a longer delay than
those assigned to Entry Delay #1.
Entry Delay #2 (partition-specific)
Enter 02-15 multiplied by 15 seconds.
00 = no delay.
NOTE: The delay may not exceed 45 seconds for UL installations.
5-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Exit Delay #2 is used for a secondary door requiring a longer delay than
those assigned to Exit Delay #1.
Exit Delay #2 (partition-specific)
Enter 03-15 multiplied by 15 seconds.
00 = no delay.
*12
NOTE: The delay may not exceed 60 seconds for UL installations.
Defines the length of time the Bell Output and the keypad’s sounder will
sound for all audible alarms.
Alarm Sounder Duration
*13
(partition-specific)
Enter 01-15 multiplied by 2 minutes.
00 = no timeout.
Must be minimum 16 minutes for UL Commercial Burglary installations.
Select the response time for devices connected to zone 9.
Zone 9 Fast/Slow Response
0 = slow 350ms
1 = fast 10ms
*14
*15
The keyswitch requires the use of zone 7 wired loop (zone 7 is no longer
available as protection zone). The fire and panic alarm voltage triggers
(J7) automatically become ARMING and READY status outputs for the
Keyswitch LEDs.
Keyswitch Assignment
Enter 1-2 partition keyswitch is being used.
Enter 0 if the keyswitch is not used.
Openings/closing report as user “0” if enabled in field *40.
If enabled, produces ½-second external alarm sounding (“ding”) at the end
of exit delay (or after kissoff from the central station, if sending closing
reports).
Confirmation of Arming Ding
(partition-specific)
0 = disable
*16
Must be 1 for UL installations.
1 = enable
If enabled, sounding at the keypad (rapid beeping) occurs when AC power
is lost (sounding occurs about 2 minutes after actual AC loss).
AC Loss Keypad Sounding
0 = disable
1 = enable
*17
*19
If enabled, randomizes AC loss reporting between 10 and 40 min. after an
actual AC loss.
Randomize AC Loss Report
0 = disable
1 = enable
If disabled, AC loss reporting about 2 minutes after actual AC loss.
Selecting this option helps prevent an overload of AC loss messages at the
central station during a community blackout.
If a 4285/4286 Voice Module is being used, enter the 2-digit phone code
used to access the system.
VIP Module Phone Code
1-9 = first digit of access code
*20
*21
or # = second digit of access code (enter #
+11 for “∗”, or # +12 for “#”)
Must be disabled for UL installations.
To disable enter 00 for the 1st digit
If enabled, there is no timeout of the alarm sounder duration for all fire
zones, regardless of partition, so that fire sounding continues until the
system is reset.
Prevent Fire Timeout
0 = disable (timeout)
1 = enable (no timeout)
If disabled, (timeout) the normal burglary sounder duration (field ✳13)
applies to fire alarms.
If enabled, the keypad panics (zones 995, 996, and 999) may be used in
this partition. There are 3 entries in this field, one for each panic.
Keypad Panic Enables (partition-
*22
*23
specific)
0 = disable
1 = enable
If enabled, allows more than one alarm sounding for a given zone during
an armed period.
Multiple Alarms (partition-
specific)
0 = disable
1 = enable
NOTE: that multiple alarm soundings will not occur more frequently
than allowed by the programmed alarm sounder duration. This has no
impact on the number of communication messages transmitted.
Must be 1 for UL installations.
5-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 – Data Field Descriptions
FIELD
TITLE and DATA ENTRIES
EXPLANATION
If disabled, the system monitors the tampers on expansion zones.
Ignore Expansion Zone Tamper
0 = disable (tamper detection)
1 = enable (no tamper detection)
*24
NOTE: Only applicable to certain polling loop sensors with tamper
switches or 5800 Series transmitters.
Must be 0 for UL installations.
If enabled, allows triggering of Output 3 (pin 7) of the J7 header to
include zone response type 8 (24-hr. auxiliary).
Burglary Trigger for Response
*25
*26
Type 8
0 = disable
1 = enable
If enabled, no test report is sent if any other type of report was sent since
the last test report.
Intelligent Test Report
0 = disable
1 = enable
If disabled, test reports are sent at the set intervals, regardless of
whether or not any other report has been sent.
Must be 0 for UL applications.
Test Report Interval
Enter 001-199 for the test report interval in
hours.
If a test report is desired, enter a test code in field *81 and *82. Set first
test report time in field *83.
*27
*28
Maximum Test report interval is 024 for UL installations.
Enter 000 for test reporting.
If enabled, the system, upon power-up, reverts to its status prior to a
complete power loss.
Power-Up in Previous State
0 = disable
1 = enable
If disabled, the system always powers up in a disarmed state.
NOTE: Neither authority level 0 nor 5 can be used to disarm the system
if the control powers up armed.
Must be 1 for UL applications.
If enabled, allows arming of the burglary system in AWAY, STAY,
INSTANT, or MAXIMUM mode by using the [#] key instead of the user
code.
Quick Arm (partition-specific)
*29
*30
0 = disable
1 = enable
NOTES:
When armed, the system reports closing as User 0 if Open/Close reporting
for User #2 (typically a Master level user) was enabled for a given
partition.
If Quick Arm is used, the Installer Code and Authority Level 5 codes
cannot disarm the system.
Select the dialing method for the system
TouchTone or Rotary Dial
0 = disable
1 = enable
If you select TouchTone, make sure the subscriber has requested and is paying for TouchTone service. Note that
whether or not TouchTone dialing for call placement is permitted, communication by the use of DTMF signaling
(ADEMCO High Speed) will still take place. See field 1*33 for TouchTone w/Rotary backup
This field is used to enter up to four 2-digit numbers representing the
prefix needed to obtain an outside telco line. If not required, enter
nothing and proceed to next field.
PABX Access Code
*31
*32
Enter 00-09; B-F (11-15)
Enter a 3- or 4-digit (depending on report format) primary subscriber
account number. Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3-digit account number is to be
used, enter data only in the first 3 locations, and enter * in the fourth
location.
Primary Subscriber’s Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
5-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Enter the primary central station phone number, up to 17 digits. This is
the phone number the control will use to transmit Alarm and status
messages to the central station. Do not fill unused spaces.
Primary Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
*33
NOTE: Backup reporting is automatic only if a secondary phone number
is entered.
Enter the secondary phone number, up to 17 digits. The secondary phone
number is used if communication on the primary number is unsuccessful,
or if split/dual reporting is desired. Do not fill unused spaces.
Secondary Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
*34
NOTE: If this field is programmed, a secondary subscriber account
number (field *90) must also be programmed.
Enter the downloading phone number, up to 17 digits. Do not fill unused
spaces.
Download Phone Number
Enter 0-9; #11 for *, #12 for #, #13 for a 2-
second pause.
*35
*36
NOTE: This field is applicable only if downloading is utilized.
Enter eight digits.
Download ID Number
Make entries as 2-digit numbers as follows:
00=0 01=1 02=2 03=3 04=4 05=5
06=6 07=7 08=8 09=9 10=A 11=B
12=C 13=D 14=E 15=F
NOTE: This field is applicable only if downloading is utilized.
Enabling a function means that you are able to perform that function via
the Compass Downloading software.
Download Command Enables
0 = disable
1 = enable
*37
Functions are as follows: Dialer Shutdown; System Shutdown; Not Used;
Remote Bypass; Remote Disarm; Remote Arm; Upload Program;
Download Program.
For UL installations, all entries must be 0.
Enter two digits for zone that cannot be bypassed by the user.
Prevent Zone XX Bypass
*38
*39
*40
*41
*42
NOTES:
(partition-specific)
Enter a zone number (01-64).
Enter 00 if all zones can be bypassed.
The actions manual bypass, and STAY/INSTANT arming modes cannot
bypass any zone programmed in this field.
If enabled, whenever the Installer Code is used to arm or disarm the
partition, an open/close report is sent to the central station.
Enable Open/Close Report for
Installer Code (partition-specific)
0 = disable
1 = enable
If enabled, whenever the keyswitch is used to arm or disarm the partition,
an open/close report is sent to the central station.
Enable Open/Close report for
Keyswitch
0 = disable
1 = enable
If disabled, end-of-line resistors must be used on zones 2-8.
Normally Closed or EOLR (Zones
If enabled end-of-line resistors cannot be used and only normally closed
devices must be used.
2-8)
0 = disable
1 = enable
Must be 0 for UL installations.
Enter the time the system waits for dial tone before dialing. Applies if
true dial tone is not selected in field *43.
Dial Tone Pause
Enter the wait time for dial tone detection:
0 = 5 seconds; 1 = 11 seconds; 2 = 30
seconds.
Must be 0 for UL installations.
5-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 – Data Field Descriptions
FIELD
TITLE and DATA ENTRIES
EXPLANATION
If enabled, the system waits for true dial tone. If no dial tone is detected,
control dials at end of pause programmed in field *42.
Dial Tone Detection
0 = disable
1 = enable
*43
If disabled, the system pauses for seconds entered in field *42, then dials.
NOTE: Disabling may be necessary in high-noise environment telco
networks where noise can be confused with dial tone, resulting in
premature dialing.
Only applicable if using a 4285/4286 VIP Module and/or if station-
initiated downloading will be used.
Ring Detection Count
Enter 00 to disable ring detection.
Enter 01-14 for ring counts of 1-14.
Enter 15 to select Answering Machine
Defeat Mode
*44
NOTES:
Do not enter 00 if a 4285/4286 is installed.
In the Answering Machine Mode, the caller should let the phone ring
once, then hang up, and call again within 30 seconds. The system, upon
hearing one ring followed by nothing, does not answer the first call, but
readies itself to pick up on the first ring of the next incoming call that is
received within 30 seconds (i.e., the downloader calling again).
Must be 00 for UL installations.
Enter the reporting format for the primary telephone number.
Primary Format
*45
*46
*47
*48
*49
0=Low Speed; 1=Contact ID; 2=ADEMCO
High Speed; 3=ADEMCO Express
Enter the low speed format for the primary telephone number.
Enter the reporting format for the secondary telephone number.
Enter the low speed format for the secondary telephone number.
Low Speed Format (Primary)
0 = ADEMCO Low Speed
1 = Sescoa/Radionics
Secondary Format
0=Low Speed; 1=Contact ID; 2=ADEMCO
High Speed; 3=ADEMCO Express
Low Speed Format (Secondary)
0 = ADEMCO Low Speed
1 = Sescoa/Radionics
If enabled, the system for either or both primary/secondary formats sends
a verification digit to validate the message at the receiver without having
to send two message rounds. Selection is valid for 3+1, 4+1, and 4+2
reports.
Checksum Verification
Enter 2 digits, one for the primary and one
for the secondary.
0 = disable
1 = enable
If disabled, selects Radionics, which uses hexadecimal 0-9, B-F reporting.
If enabled, selects Sescoa, which uses only numeric reporting (0-9).
Sescoa/Radionics Select
0 = disable
1 = enable
*50
*51
NOTE: The selection applies to both primary and secondary phone
numbers.
If enabled, all reports are to be sent to both primary and secondary phone
numbers.
Dual Reporting
0 = disable
1 = enable
NOTE: If used with Split Reporting option 1 (1*34), alarms go to both
primary and secondary numbers, while all other reports go to secondary
only. If used with Split Reporting option 2, alarms go to both lines,
open/close and test messages go to secondary only, while all other reports
go to primary.
5-5
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
primary phone number if low speed format is selected in field *45.
Standard/Expanded Reporting
*52
Primary
0 = disable
1 = enable
NOTE: Expanded overrides 4+2 format.
This field has six entries as follows: Alarm, Restore, Bypass, Trouble,
Open/Close, Low Battery. If enabled, expanded reports are sent to the
secondary phone number if low speed format is selected in field *47.
Standard/Expanded Reporting
*53
Secondary
0 = disable
1 = enable
NOTE: Expanded overrides 4+2 format.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 01–08
ID Digit for Zones 01–08
*54
*55
*56
*57
*58
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 09–16
ID Digit for Zones 09–16
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 01–16
Enter 00-15.
NOTE: Each report code is the same for zones 01-16. When using 4+2
format, the system uses the ID digit of the zone (fields *55 and *57).
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 17–24
ID Digit for Zones 17–24
*59
*60
*61
*62
*63
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 25–32
ID Digit for Zones 25–32
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 17–32
Enter 00-15.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *60 and *62).
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 33–40
ID Digit for Zones 33–40
Alarm Code for Zones 41–48
ID Digit for Zones 41–48
*64
*65
*66
*67
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
5-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 – Data Field Descriptions
FIELD
TITLE and DATA ENTRIES
EXPLANATION
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 33–48
Enter 00-15.
*68
NOTE: Each report code is the same for zones 33-48. When using 4+2
format, the system uses the ID digit of the zone (fields *65 and *67).
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 49–56
ID Digit for Zones 49–56
*69
*70
*71
*72
*73
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 57–64
ID Digit for Zones 57–64
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 49–64
Enter 00-15.
NOTE: Each report code is the same for zones 49-64. When using 4+2
format, the system uses the ID digit of the zone (fields *70 and *72).
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 87–88
ID Digit for Zones 87–88
*74
*75
*76
*77
*78
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 89–99
ID Digit for Zones 89–99
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 87–99
Enter 00-15.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *75 and *77).
This field has eight entries, one for each zone type. Select the zone types
that will send Restore reports.
Zone Type Restores for Zone
*79
*80
*81
Types 1-8
0 = disable
1 = enable
This field has two entries, one for each zone type. Select the zone types
that will send Restore reports.
Zone Type Restores for Zone
Types 9 and 10
0 = disable
1 = enable
This field has ten two-digit entries as follows: Close, Open Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code 01-15 for each type of report.
Enter 00 for no report.
Non-Alarm Report Codes (First
Digit
Enter 00-15.
5-7
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
This field has ten two-digit entries as follows: Close, Open, Low Battery,
Low Battery Restore, AC Loss, AC Restore, Test, Power-up, Cancel, and
Program Tamper. Enter the report code 01-15 for each type of report.
Enter 00 for no report.
Non-Alarm Report Codes
(Second Digit
Enter 00-15.
*82
Enter the day and time that the first Test report shall be transmitted.
Enter 00 in all locations if the Test report is to be sent immediately upon
exiting. Enter 00 in the day location if the report is to be sent at the next
occurrence of the time that is set.
First Test Report Time
Enter 00-07 the for day (01 = Monday)
Enter 00-23 for the hour
*83
*84
*85
*86
Enter 00-59 for the minutes
This option limits the number of messages (alarms or troubles) sent for a
specific zone in an armed period.
Swinger Suppression (partition-
specific)
Enter 01-15.
Must be 00 for UL installations.
Enter 00 for unlimited reports
This field has four entries as follows: Zone 95, 96, 99, and Duress. Enable
for each partition that the panics and duress reporting is desired.
Enable Dialer Reports for Panics
& Duress (partition-specific)
0 = disable
NOTE: Non-zero report code must be assigned to zone 92 to enable
Duress reporting.
1 = enable
Entering 1 allows a single 4208 to be set to zone numbers 10-17, but
precludes the use of any other polling loop devices.
Entering 0 allows all other configurations, such as no 4208, more than
4208 Module Zone Assignment
0 = other configurations
1 = 10-17 only
one 4208, or other polling loop expansion present.
4208 Zone #s available when:
When *86 = 1 4208 DIP switches must be set to:
*86 = 1
10-17
*86 = 0
10-16
With word OFF
sw 2 = ON
With word ON
sw 2 = OFF
sw 3 = OFF
sw 4 = OFF
sw 5 = ON
Precludes use 17-24
of any other
sw 3 = ON
25-32
sw 4 = ON
polling loop
33-40
sw 5 = OFF
expansion
41-48
49-56
57-64
Select the type of warning for the entry delay period.
Entry Warning (partition-specific)
0 = 3 short beeps
1 = slow continuous beeps
*87
*88
Select the delay, if any, for burglary alarm communications.
Burglary Alarm Communicator
Delay (partition-specific)
0 = no delay
Must be 0 for UL installations.
1 = 16-second delay
Select the time when restore reports are sent after an alarm.
Restore Report Timing
0 = instant
1 = after bell timeout
*89
*90
Must be 2 for UL installations.
2 = when system is disarmed
Enter a 3- or 4-digit (depending on report format) secondary subscriber
account number. Each number requires a 2-digit entry so as to allow
entry of hexadecimal digits (B-F). If a 3-digit account number is to be
used, enter data only in the first 3 locations, and enter * in the fourth
location.
Secondary Subscriber Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
NOTE: This field must be programmed if a secondary phone number is
used (field *34). This account number can be the same as the primary
account number.
5-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 – Data Field Descriptions
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Response Types for Zones 28–32
1*01
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Response Types for Zones 33–40
Response Types for Zones 41–48
Response Types for Zones 49–56
Response Types for Zones 57–64
Response Types for Zones 87–91
RF Transmitter Low Battery
1*02
1*03
1*04
1*05
1*09
1*28
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Skip this field. Use #93 Menu Mode, Zone Programming to program the
response types. Refer to the Programming Guide for details.
Select when the RF transmitter low-battery condition should display and
audible beep annunciate on the keypad.
Sound
Must be 1 for UL installations.
0 = disarmed state only
1 = both armed and disarmed states
If enabled, the system sends a Trouble message for RF transmitter low-
battery condition to the central station.
RF Transmitter Low Battery
1*29
1*30
Reporting
0 = disable
1 = enable
NOTE: The Trouble message will be sent for a transmitter supervision
failure, independent of this selection.
Must be 1 for UL.
Select the check-in monitoring interval for the RF receiver(s).
RF Receiver Supervision Check-
in Interval
Enter 02-15 times 2 hours (4-30 hours).
00 = disable receiver supervision.
Failure of a receiver to receive any RF signal within the time entered
results in the activation of the response type programmed for zone 990 for
the first receiver and zone 988 for the second receiver and their related
communication reports.
Maximum is 2 (4 hr) for UL installations.
Select the check-in monitoring interval for the RF transmitters.
RF Transmitter Check-in Interval
Enter 02-15 times 2 hours (4-30 hours).
00 = disable transmitter supervision.
1*31
Failure of an individual transmitter to send a supervision signal within
the time entered will result in a trouble response and related
communication report.
Maximum is 2 (4 hr) for UL.
If enabled, the system reverts to rotary dialing if communicator is not
successful in dialing using TouchTone DTMF on first attempt.
TouchTone with Rotary Backup
1*33
1*34
0 = disable
1 = enable
Select the type of split reporting for system communication.
Communicator Split Reporting
0 = Split Reporting disabled
NOTE: See *51 for split/dual reporting combinations.
1 = Alarm, Alarm Restore, and Cancel
reports to primary, all others to secondary
2 = Open/Close and Test reports to
secondary, all other reports to primary
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 65–72
1*35
5-9
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
ID Digit for Zones 65–72
1*36
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
Alarm Code for Zones 73–80
ID Digit for Zones 73–80
1*37
1*38
1*39
Skip this field. Use #93 Menu Mode, Zone Programming to program the
report codes. Refer to the Programming Guide for details.
This field has five two-digit entries as follows: Alarm Restore, Trouble,
Trouble Restore, Bypass, and Bypass Restore. Enter the report code 01-15
for each type of report. Enter 00 for no report.
Supervisory and Restore Codes
for Zones 65–80
Enter 00-15.
NOTE: Each report code is the same for zones 17-32. When using 4+2
format, the system uses the ID digit of the zone (fields *75 and *77).
This field has two two-digit entries as follows: Arm STAY, and Time/Date
set or Event Log Reset. Enter the report code 01-15 for each type of
report. Enter 00 for no report.
Arm Stay and Time Set Report
Codes (First Digit)
Enter 00-15.
1*40
1*41
1*43
This field has two two-digit entries as follows: Arm STAY, and Time/Date
set or Event Log Reset. Enter the report code 01-15 for each type of
report. Enter 00 for no report.
Arm Stay and Time Set Report
Codes (Second Digit)
Enter 00-15.
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
Permanent Keypad Display
Backlighting (partition-specific)
0 = disable
1 = enable
NOTE: When a key is pressed, display backlighting turns on for all
keypads in that partition.
If enabled, when more than 40 key depressions are received without a
valid sequence (arm, disarm, etc.), the control panel disables the wireless
keypad. The inhibit is removed once a valid key sequence is received from
a wired keypad.
Wireless Keypad Tamper Detect
1*44
1*45
0 = disable
1 = enable
If enabled, the system produces slow beeping from the keypads during
exit delay and reverts to rapid beeping during the last 10 seconds of the
exit delay.
Exit Delay Sounding (partition-
specific)
0 = disable
1 = enable
NOTE: The duration of the beeping is the programmed value of field *10
regardless of which entry/exit zone is used to exit the premises.
Select the mode for output 1 on the J7 triggers.
NOTES:
Auxiliary Output Mode
0 = ground start output.
1 = open/close trigger.
2 = keypad sounds at an auxiliary sounder.
3 = AAV module.
1*46
Only one of the options may be active within the system.
Open/close trigger is produced only when both partitions are armed.
Keypad sounds apply only to the partition enabled in field *15.
If enabled, the system produces chime annunciation on the external
alarm sounder.
Chime on External Siren
(partition-specific)
0 = disable
1*47
1*48
1 = enable
Select the partition in which RF keypad is used.
Wireless Keypad Assignment
0 = none
1-8 = partition number
5-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5 – Data Field Descriptions
FIELD
TITLE and DATA ENTRIES
Suppress Transmitter
Supervision Sound
0 = disable
EXPLANATION
If enabled, no trouble soundings occur on the keypad for transmitter
check-in failures.
1*49
Must be 0 for UL.
1 = enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
Send Cancel If Alarm + Off
(partition-specific)
0 = disable
1*52
If disabled, Cancel reports are sent within Bell Timeout period only.
1 = enable
NOTE: This option must be enabled so Cancel reports are always sent.
Select whether a callback from the control panel is required for
downloading.
Disable Download Callback
0 = callback required
1 = no callback required
1*53
1*57
Must be 0 for UL installations.
If enabled, the system arms/disarms in accordance with the button’s
user’s global arming settings.
Enable 5800 RF Button Global
Arm
0 = disable
1 = enable
If enabled, allows the RF button user to force a bypass of all faulted zones
when arming the system.
Enable 5800 RF Button Force
1*58
Arm
0 = disable
1 = enable
NOTE: When attempting to arm the system, the keypad beeps once after
the button is pressed if any faulted zones are present. The user should
then press the button again within 4 seconds to force-bypass those zones
and arm the system.
If enabled, zone 5 is used for 2-way audio (AAV).
Must be 0 for UL installations.
Zone 5 Audio Alarm Verification
1*60
1*70
1*71
0 = disable
1 = enable
NOTE: Zone 5 cannot be used as protection zone.
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
and System. If enabled, the system logs those events into the event log.
Event Log Types
0 = disable
1 = enable
Select the type of time stamping for the event log.
12/24 Hour Type Stamp Format
0 = 12-hour
1 = 24-hour
This is used for Relay Programming in the #93 Menu Mode Programming
relay command “56.”
Relay Timeout XXX Minutes
1*74
1*75
1*76
Enter 000-127 times 2 minutes (000-254).
This is used for Relay Programming in the #93 Menu Mode Programming
command “57.”
Relay Timeout YYY Seconds
Enter 000-127 seconds.
If enabled, the assigned relay closes for 2 seconds when the user enters
his code and presses 0.
Must be 00 for UL installations.
Access Control Relay (partition-
specific)
01-08 = relay number
00 = relay not used.
Enter the number of partitions used in the system.
Enter the months (00-12) in which daylight saving time starts and ends.
Number of Partitions
2*00
2*01
Enter 1-2.
Daylight Saving Time Start/End
Enter 00, 00 if daylight saving time does not apply to the user’s region.
Standard setting for U.S. is 04,10.
Month
0 = disable
1 = enable
5-11
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
EXPLANATION
Enter the start and end weekends for daylight saving time as follows:
1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from
last. Standard setting for U.S. is 1,5.
Daylight Saving Time Start/End
2*02
Weekend
0 = disable
1 = enable
This field has two 2-digit entries. Enter the number user codes for each
partition. The total number of user codes cannot exceed 70 for the system.
Enter 01 for an unused partition.
Number of Codes per Partition
2*17
2*18
Enter 01-69
NOTE: The installer code is automatically assigned to each partition
regardless of whether that partition has been enabled.
If enabled, this partition can be accessed from another partition’s keypad
using the GOTO command.
Enable GOTO for this Partition
(partition-specific)
0 = disable
1 = enable
If enabled, the normal keypad display will include a partition number and
four-digit descriptor.
Use Partition Descriptor
0 = disable
1 = enable
2*19
2*20
If enabled, the J7 triggers function for this partition.
Enable J7 Triggers for Partition
(partition-specific)
0 = disable
1 = enable
There are three entries in this field as follows: Fire, Burglary/Audible
Panic, Silent Panic/Duress.
Supervision Pulses for LRR
0 = disable
1 = enable
2*21
If enabled, causes the control to send periodic short pulses on the J7 radio
triggers to the LRR. The LRR uses these pulses to determine that its
connection to the control is still intact.
Must be 1 for UL installations.
5-12
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
6
Downloading Primer
(Remote Downloading is not a UL Listed feature)
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
Access Security
Downloading allows the operator to remotely access,
program, and control the security system over normal
telephone lines. Anything that can be done directly
from the keypad can be done remotely, using the
COMPASS downloading software. To communicate
with the control panel, the following is required:
The following four levels of protection guard the control
against compromise while it is being accessed from a
remote location:
1. Security code handshake: The subscriber’s account
number as well as an 8-digit ID number (known
only to the office) must be matched between the
control and computer.
1. IBM PC-compatible 486 33MHz PC or better with
30 MB of available hard disk space and at least
8MB of RAM (12MB is preferred). Windows 3.X,
Windows 95, 98, or Windows NT.
2. Hang-up and callback: The control panel “hangs
up” and calls the computer back at the pre-
programmed number only if the security codes
match.
2. One of the following modems:
•
•
ADEMCO CIA
3. Data encryption: All data that is exchanged
between the computer and control is encrypted to
reduce the possibility of anyone “tapping” the line
and corrupting data.
Hayes Smartmodem 1200 (external: level 1.2 or
higher; internal: level 1.1 or higher)
•
•
•
•
Hayes Optima 24 + Fax 96 external
Hayes Optima 336
4. Operator access levels: Operators may be assigned
various levels of access to the downloader, each
having its own log-on code. The access levels allow
the operators read/write capabilities of the
customers’ account information. For a detailed
explanation of the access levels, see the
BizComp Intellimodem 1200 w/volume
BizComp Intellimodem 2400
Other brands are not compatible, even if claimed to
be 100% compatible.
3. COMPASS DOWNLOADING software available on
CD ROM with a complete User’s Manual. It may
also be downloaded from the Honeywell web page.
downloading software User Manual.
NOTES:
•
Each time the control panel is accessed
successfully, a Callback Requested report is sent to
the central station, if Opening reports are
programmed.
Internal modems must have a 4-position DIP
switch. Modems with a 6-position DIP switch
will not work.
•
•
When the system is downloading, the keypad
displays “MODEM COMM.”
After each download or save, an automatic time
stamp is done, to indicate the last download (or
save) and the operator ID number.
•
A complete hard copy of each individual account
can be obtained by connecting a printer to the
computer. Refer to your computer Owner’s Manual
or contact your dealer for printer recommendations.
6-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Getting On-Line with a Control Panel
At the protected premises, the control panel must be
connected to the existing telephone line (refer to
SECTION 3: Installing the Control). No programming
of the panel is required before downloading to an initial
installation unless you are performing an unattended
download.
To download a control without programming any
information, perform the following steps:
Step
Action
1
Enter the Installer Code + [#] + [5]. The
panel temporarily enables a ring count of 5
and sets the Download Callback option to “1”
(callback not required).
When establishing a connection between the computer
and the control panel, the following occurs:
2
From the computer, call the panel using the
downloader software set to “First
Communication” Mode.
Stage
What Happens
1
The computer calls up the control panel.
(The phone number for each customer must
be entered into the customer’s account file
on the computer.)
The downloader establishes a session with no
callback. The panel information can then be
downloaded.
2
The control panel answers the phone call at
the pre-programmed ring count and executes
a handshake with the computer.
On-Line Control Functions
The following functions can be performed while on-line
with a control panel (see field *37):
3
4
The computer sends a request for callback to
the control, unless callback is not required.
•
Arm the system in the AWAY Mode; disarm the
system
The panel acknowledges the request and
hangs up. During the next few seconds, the
control processes the request, making sure
certain encrypted information received from
the computer matches its own memory.
•
•
Bypass a zone
Force the system to accept a new program
download
•
Shut down communication (dialer) functions (for
nonpayment of monitoring fees in an owned
system)
5
Upon a successful match, the control panel
seizes the phone line and calls the computer
back, unless callback is not required. (The
phone number to which the computer’s
modem is connected must be programmed
into the control field ✳35.)
•
•
•
Shut down all security system functions (for
nonpayment for a leased system)
Inhibit local keypad programming (prevents
takeover of your accounts)
6
7
The computer answers, usually by the
second ring, and executes a handshake with
the panel.
Leave a message for customer
NOTE: Messages sent to the control panel from the
downloader will be viewable at ALL partitions.
The panel then sends other default
information to the computer. If this
information matches the computer’s
information, a successful link is established.
The system is now “on-line” with the
computer.
•
•
Command the system to upload a copy of its
resident program to the office
Read: arming status, AC power status, list of
faulted zones, list of bypassed zones, 100 event log,
list of zones currently in alarm, list of zones
currently in trouble, and ECP equipment list
•
Set the real-time clock
Alarms and Trouble responses and reports are
disabled during actual uploading or
downloading sessions.
6-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 24 - Downloading Primer
Direct-Wire Downloading
The VISTA-40 can be downloaded without using a
modem or telephone line by using a 4100SM Serial
Module and Compass Downloading Software. The
direct-wire downloading connection is to be temporary,
and is not part of the permanent installation. Direct-
wire downloading is meant as a tool for the installer
during the installation process.
Connector J8 on the main PC board (see the Summary
of Connections diagram on the inside back cover of this
manual) is intended to be interfaced to either a local
serial printer (see SECTION 3:Installing the Control) or
a computer. Make connections to a computer as shown
below. Note that the violet wire connection for a
computer differs from that used when connecting
a serial printer.
The connections between the control and the
4100SM are different than those shown in the
4100SM Installation Instructions. See Figure 6-
1 for the correct connections. In addition, in
place of the green wire, referred to in step 2 of
the “IN CASE OF DIFFICULTY” section of the
4100SM Instructions, use the violet wire
instead.
Figu r e 6-1: Dir ect-Wir e Down loa d in g Con n ection s
Telco Handoff
Telco handoff is another method of getting on-line with the downloader. The installer or customer enters the User Code
+ [#] + [1], while on the phone line with the computer’s modem phone line. The customer will get cut-off and the panel
and download computer will establish a connection.
6-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
6-4
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
7
Setting the Real-Time Clock
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
Use a 6139/6160 alpha keypad to set the real-
time clock, or set the clock via the downloader
software. Only users with Installer or Master
authority level can set the clock.
This system provides a real-time clock, which must be
set in order for the system’s event log to keep track of
events by time and date.
Setting the Time and Date
To set the real time clock, perform the following steps:
Step
Action
1
Enter Installer or Master Code + [#] 63.
Typical display shows:
TIME/DATE –– THU
12:01 AM
01/01/90
The day of the week is automatically
calculated based on the date entered. Time
and date entries are made by simply entering
the appropriate hour, minute, month, day
and year.
Press [✳] to move the cursor to the right of
the display, to the next position.
Press [#] to move the cursor to the left of the
display, to the previous position.
2
3
4
Enter the correct hour. Then press [✳] to
move to the “minutes” field.
Enter the correct minutes. Press [✳] to move
to the AM/PM position.
Press any key 0-9 to change AM to PM, or PM
to AM. Press [✳] to move cursor to the
“month” field position.
5
6
7
Enter the correct month using a 2-digit entry.
Press [✳] to move cursor to the “day” field
position.
Enter the correct day using a 2-digit entry.
Press [✳] to move cursor to the “year” field
position.
Enter the correct year.
Press [✳] to continue.
7-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
7-2
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
8
User Access Codes
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
The VISTA-40 allows a total of 70 security access codes
to be allocated. Each security access code is identified
by a user ID number. A maximum of 69 user codes may
be assigned to any one of the partitions. The installer
code is automatically assigned to both partitions
regardless of whether both partitions are used.
User code number 2 must be programmed in
order for the Quick Arm feature to function.
Open/Close reporting for Quick Arm is enabled if
User 2 is enabled for Open/Close and reports as
User 0.
The Quick Arm feature can also be programmed
(partition-specific program field *29). The Quick Arm
feature allows the user to arm the system by pressing
the [#] key instead of the security code. The security
code must always be entered to disarm the system.
User Codes & Levels of Authority
Each user of the system can be assigned a level of
authority, which authorizes the user for certain system
functions. A user can have different levels of authority
within different partitions
Use the “View Capabilities” keypad function (User
Code + [✳] + [✳]) to view the partitions and authority
levels for which a particular user is authorized. These
levels are described below.
Level 0: Installer (User 1) Code
Level 2: Manager Codes
•
Programmed in field *00 (default = 4-1-4-0).
Installer Open/Close reporting selected in field *39.
•
Can perform all system functions (arm, disarm,
bypass, etc.) programmed by Master.
•
Can perform all system functions (arm, disarm,
bypass, etc.), but cannot disarm if armed by
another code (or by Quick Arm).
•
May add, delete, or change other users of the
system below this level (Manager cannot assign
anybody a level of 0, 1, or 2).
•
•
Can add, delete, or change all other codes, and can
select Open/Close reports for any user.
Is the only code that can be used to enter program
mode. The Installer Code can be prevented from re-
entering the Program Mode by exiting using ∗98.
Must program at least one Master Code during
initial installation. Master Codes are codes
intended for use by the primary user(s) of the
system.
•
•
May change his own code.
Open/Close reporting is automatically the same as
that of the Manager who is adding the new user.
Levels 3-5: Operator Codes
•
Can operate a partition, but cannot add or modify
any user code (see table below).
•
Level Title
Functions Permitted
Arm, Disarm, Bypass
Arm, Disarm
3
4
5
Operator A
Level 1: Master Codes
Operator B
Operator C
•
•
Can perform all normal system functions.
Can be used to assign up to 68 lower-level codes,
which can be used by other users of the system.
Cannot assign anybody a level of 0 or 1.
May change his own code.
Can add, delete, or change Manager or Operator
Codes. Each user’s code can be individually
eliminated or changed at any time.
Arm, Disarm only if armed with
same code
•
Operator C (sometimes known as the Babysitter
Code) cannot disarm the system unless the system
was armed with that code. This code is usually
assigned to persons who may need to arm and
disarm the system at specific times only (e.g., a
babysitter needs to control the system only when
babysitting).
•
•
•
•
Open/Close reporting is automatically the same as
that of the Master who is adding the new user.
8-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Level 6: Duress Codes
Duress Reporting Note: A non-zero report
code for zone 92 (duress) must be programmed,
and partition-specific field *85 duress location
enabled, to enable Duress reporting.
•
Sends a silent alarm to a central monitoring station
if the user is being forced to disarm (or arm) the
system under threat (system must be connected to
a central station).
•
The Duress report-triggering logic activates on the
5th key depression (such as OFF), not the 4th key
depression (last digit of code). Duress reports are
not triggered if the 5th key is a [*], such as when
you perform a GOTO or view the capabilities of a
user.
•
When the system’s Auxiliary Voltage Triggers are
connected to another communication’s media
(Derived Channel/Long Range Radio), note that
duress is signaled on the same trigger that signals
silent panic (whereas duress has its own unique
report when digitally communicated).
•
Assigned on a partition-by-partition basis, and can
be any code or codes desired.
Open/Close Reporting Note: When a user is added,
the system prompts for Open/Close reporting capability
only if the installer is adding the new user. When a
Master or Manager adds a new user, the new user’s
Open/Close reporting is the same as that of the Master
or Manager who is adding the user. If Open/Close
reports are required to be selectable by the Master or
Manager, the Installer should assign two Master or
Manager user codes: one with Open/Close reporting
enabled, and one without.
General Rules on Authority Levels and Changes
The following rules apply to users when making modifications
within the system based on the user code authority levels:
•
Master Codes and all lower-level codes can be used
interchangeably when performing system functions within a
partition (a system armed with a user’s temporary code can
be disarmed with the Master Code or another user’s
temporary code), except the Operator Level C Code
described above.
•
•
•
•
•
A user may not delete or change the user code of the SAME
or HIGHER authority than that which he is assigned.
Note that Open/Close reporting of Quick Arm is enabled
if User 02 is enabled for Open/Close reporting, and that
Quick Arm reports as User 00. In order for Quick Arm
reports to be sent for all partitions, User 02 must have
authority and Open/Close must be enabled for all
partitions. If a code with access to all partitions is not
desired, it is suggested that user 02 be assigned
authority level 5 in all partitions, and that the code be
kept secret. Authority level 5 cannot disarm the system
unless armed by that user.
A user (levels 0, 1 and 2 only) may only ADD users to a
LOWER authority level.
A user may assign other users access to only those
partitions to which he himself has access.
A user code can be DELETED or CHANGED only from
within the partition it was created in.
User numbers must be entered in 2-digits. Single-digit user
numbers must, therefore, always be preceded by a “0” (e.g.,
03, 04, 05, etc.). Make sure the end user understands this
requirement. Temporary codes are entered as 4-digit
numbers.
ADEMCO Contact ID format is capable of
reporting Users 01-70 uniquely. If any other
report format is used, only user numbers 01 –
15 can uniquely report to the central station.
Users 16 – 70 will report as User 15.
Multiple Partition Access
Each user is programmed for a primary (home)
partition. A user can also be given access to operate one
or both partitions. Within each partition, each user
may be programmed to have different levels of
authority. For example, User 03, the VP of
Engineering, could be assigned to work within the
Engineering Department (Partition 1) of ABC
Manufacturing. Because he needs the full capabilities
in his area, he is assigned as a MASTER with Level 1
authority.
The control automatically assigns him the same user
number within Partition 2.
EXAMPLE OF MULTIPLE PARTITION ACCESS
Part 1
Part 2
User 3
Level 1
Master
User 3
Level 4
Oper B
In the above example, User 3 has MASTER authority in
Partition 1 and OPERATOR B authority in Partition 2.
His user number is the same for both partitions.
He must also be able to gain access to the
manufacturing area (Partition 2) on an emergency
basis. You can set this up easily by requesting that he
also be assigned to Partition 2, with a level of authority
set lower, such as Level 4 (OPERATOR Level B).
8-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 9 – User Access Codes
Adding a Master, Manager, or Operator Code
†
During user code entry, normal key
Enter Installer Code + [8] + new user no. (02-69) +
new user’s code
depressions at other keypads in a partition are
ignored. However, panic key depression
causes an alarm and terminates user entry.
†
Or Master or Manager Code, but the code must be a
higher level of authority than the code being changed
(e.g., a Manager Code can add an Operator-level Code,
but cannot add a Master or another Manager Code).
Keypad prompts for the authority level for this user.
PROMPT
EXPLANATION
Enter the level number as follows:
1 = Master
User Number = 03
Enter Auth. Level
2 = Manager
3 = Operator Level A
4 = Operator Level B
5 = Operator Level C
6 = Duress
Keypad then prompts for Open/Close reporting option for this user.
Press 0 (NO) or 1 (YES), depending on whether or not arming/disarming by this user will trigger Opening
and Closing reports. This prompt appears only if the Installer Code is used to add a user.
Open/Close Rep.?
0 = NO , 1 = YES
If a 5800 Series button transmitter has been enabled for arming/disarming functions, and is not assigned to
a user, this prompt appears. Press 0 (NO) or 1 (YES).
RF Button ?
0=NO , 1=YES
If you answered “yes” to the RF button question, the zone number for the button is requested. Enter any
one of the zone numbers assigned to the button transmitter as AWAY, STAY, or DISARM. The system then
assigns all buttons of the transmitter to this user number.
Enter Button ZN #
(01-63)
Press 0 (NO) if the user is to have access to this partition only. Press 1 (YES) if the user is to have access
to more than one partition. If NO, the program exits this mode. If YES, the keypad prompts for the Global
Arm option for this user.
Multi-Access ?
0 = NO , 1 = YES
Press 0 (NO) or 1 (YES), depending on whether this user will be allowed to arm more than one partition via
Global Arm prompts.
Global Arm ?
0 = NO , 1 = YES
The keypad now prompts for the user’s access to the next partition.
Press 0 (NO) or 1 (YES), depending on whether this user will have access to the displayed partition
number. If NO, the keypad displays this prompt for the next partition number in sequence.
Part. 2 – SHOP ?
0 = NO , 1 = YES
If YES, the keypad prompts for the following:
•
•
•
User’s authority level in the displayed partition (see Authority Level prompt above).
Open/Close option for this user in the displayed partition (see Open/Close prompt above).
Global Arm option for this user in the displayed partition (see Global Arm prompt above).
When all partitions have been displayed, the keypad will scroll through all partitions to which access has
been assigned, and will display the user number, authority level, open/close and global arm options that
were programmed for each partition to which the user was granted access. See next prompt.
Note that the “G” following the authority level indicates that the global arm feature is enabled for this user in
the displayed partition, and that the period at the end of the second line indicates Open/Close reporting is
enabled for this user in the displayed partition. The “ ” indicates the partition from which the user may be
changed or deleted.
Part. 1 A0 WHSE
User 03 Auth=3G.
8-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Changing a Master, Manager, or Operator Code
*
Enter Installer Code + [8] + new user no. (02-69) + new user’s code
*
Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a
Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code).
PROMPT
EXPLANATION
The system detects that the user number is already assigned, and prompts if this is a new user.
Press 0 (NO).
User Number = 03
NEW USER?
The system then confirms that the change is allowed based on authorization level.
Adding an RF Key to an Existing User
To add an RF key to an existing user, or to change a user’s global arm option, first delete that user’s code, then re-add
the user code as described in the “Adding a Master, Manager, or Operator Code” paragraph.
Deleting a Master, Manager, or Operator Code
*
Enter your code + [8] + new user no. (02-69) + your code again
*
Or Master or Manager Code, but the code must be a higher level of authority than the code being changed (e.g. a
Manager Code can add an Operator-level Code, but cannot add a Master or another Manager Code).
PROMPT
EXPLANATION
The system prompts to confirm that you want to delete this user. Press 0 (NO) or 1 (YES).
OK TO DELETE 03?
If you answer “yes,” that user’s code is removed from all partitions to which it was assigned, and all
authorization levels and other information about that user are deleted. Note: A user can be deleted only by
a user with a higher authority level. A user cannot delete himself.
0=NO
1=YES
A user code can be deleted only from the partition through which it was entered. If an attempt is made to
delete from another partition, the message “User [XX] Not Deleted” is displayed.
Exiting the User Edit Mode
Press either [7] or [#], or don’t press any key for 10 seconds.
8-4
Download from Www.Somanuals.com. All Manuals Search And Download.
S E C T I O N
9
Testing the System
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Battery Test
When AC power is present, the VISTA-40 runs a brief
battery test every 4 hours to determine if there is a
battery connected.
It also sends a Low Battery report to the central station
(if programmed). The keypad is cleared by entering any
security code + OFF, and a Restore report is sent to the
central station if the situation has been corrected.
If the VISTA-40 finds that the battery voltage is low
(less than approximately 11.5V), it initiates a keypad
“SYSTEM LOBAT” display and a rapid keypad beeping
sound.
Dialer Test
The VISTA-40 may be programmed to automatically
transmit test reports to a central station at intervals
ranging from once per hour to once per 199 hours (field
✳27).
UL requires the test report to be transmitted at least
once every 24 hours. The system can be programmed to
send the first report at any time of the day, or on any
day of the week (field ✳83).
Burglary Walk-Test (Code + [5] TEST)
This test causes the system to sound keypad beeps in
response to faults on zones for the purpose of allowing
proper zone operation to be checked without triggering
alarms. This test can be activated by any-level user by
entering the corresponding security code and pressing
TEST while the burglary portion of the system is
disarmed. UL requires that this test be conducted on a
weekly basis.
Open and close each protected door and window in turn.
Each action should produce 3 beeps from the keypad.
Walk in front of any motion detectors. Listen for three
beeps when the detector senses movement.
The keypad displays the zone number and alpha
descriptor while a door or window remains open or
while a detector remains activated. The system
automatically issues a Zone 8 Glassbreak Detector
Power Reset about 10 seconds after it finds a fault on
this zone, to allow faulted detectors to be reset.
When this test is first entered, the system activates the
alarm output for 3 seconds. The system sends a test
message to the central station. The keypad displays
“Test in Progress” and sounds a single beep every 15
seconds while the test remains active.
To end this test, enter any security code and press OFF.
Armed Burglary System Test
To perform an armed burglary test, proceed as follows:
Alarm messages are sent to the central station
during the armed system tests. Notify the
central station that a test will be in progress.
Step
Action
1
Notify the central station that a test of the
system is being performed.
2
3
4
Arm the system.
A display of “COMM. FAILURE” indicates a
failure to communicate (no kissoff by the
receiver at the central station after the maximum
number of transmission attempts is tried). If this
occurs, verify that the phone line is connected,
the correct report format is programmed, etc.
Fault one or more zones.
Silence alarm sounder(s) each time by
entering the code and pressing OFF.
NOTE: The system must be rearmed after
each code + off sequence.
5
Check that entry/exit delay zones provide the
assigned delay times.
9-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Step
Action
6
Check the keypad-initiated alarms, if
programmed, by pressing the panic key pairs
(✳ and #, 1 and ✳, and/or 3 and #).
The word ALARM and a descriptor “99” are
displayed for ✳ and #. If [1] and [✳] are
pressed, “95” is displayed; if [3] and [#] are
pressed, “96” is displayed.
7
8
If the system has been programmed for
audible emergency, the keypad emits a loud,
steady alarm sound. Silence the alarm by
entering the security code and pressing OFF.
If the system has been programmed for silent
panic, there are no audible alarms or
displays. A report is sent to the central
station, however.
Notify the central station that all tests are
finished, and verify results with them.
Testing Wireless Transmitters
Transmitter ID Sniffer Mode
Go/No Go Test Mode
Use the Transmitter Sniffer Mode to test that
transmitters have all been properly programmed.
Checking the transmitters in this mode assists in
determining good mounting locations, and verifies that
the RF transmission has sufficient signal amplitude
margin for the installed system.
If a transmitter does not have its serial number
“enrolled,” it will not turn off its zone number.
•
All partitions containing wireless
transmitters must be placed in the test
mode for sensitivity reduction of the RF
receiver (50% sensitivity). Otherwise, the
RF receiver remains at full strength.
To enter the Transmitter ID Sniffer Mode, proceed as
follows:
•
Make sure that all partitions are disarmed
when performing this test, as the wireless
receiver gain is reduced in half.
Step
Action
1
Enter Installer Code + [#] + [3]. The
keypad displays all zone numbers of wireless
units programmed into the system.
To enter the Go/No Go Test Mode, proceed as follows:
Step
Action
2
3
Fault each wireless zone, causing each device
to transmit.
1
2
Enter Installer Code + [5].
Fault each wireless transmitter, causing each
device to transmit.
As the system receives a signal from each of
the transmitters, the zone number of that
transmitter disappears from the display.
NOTE: If a single receiver is used, the
keypad beeps three times to indicate signal
reception. If two receivers are used, the
keypad beeps once if the first receiver
received the signal, twice if the second
receiver received the signal, and three times
if both receivers heard the signal.
Enter Installer Code + OFF to exit the
Sniffer Mode.
3
4
If the keypad does not beep, reorient or move
the transmitter to another location. Usually
a few inches in either direction is all that is
required.
Enter Installer Code + OFF to exit the
Go/No Go Test Mode.
9-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 10 – Testing The System
Trouble Conditions
Check or Trouble Messages
Power Failure
Display Description
Display
CHECK
Description
This indicates that a problem exists on
the zone number displayed. Zone trouble
may be caused by one of the following
conditions:
AC LOSS
This indicates that the system is
operating on battery power only. Check
to see that the circuit breaker for the
branch circuit that your system’s
transformer is wired to has not been
accidentally turned off. Instruct the
user to call a service representative
immediately if AC power cannot be
restored.
POWER
LED is off
•
•
•
•
A hardwired fire zone is open
(broken wire).
A Day/Night zone (zone type 5) is
faulted.
A polling loop zone is not seen by
the control panel.
A polling loop zone has been
tampered (cover removed on a
4190).
Other System Messages
Display
Description
COMM
FAILURE
This indicates that a failure occurred in
the telephone communication portion of
your system.
•
A wireless zone has not checked in
during the time programmed in field
1✳31.
LO BAT
This indicates that a low-battery
condition exists in the wireless
transmitter displayed. Pressing any key
silences the audible warning sound.
•
•
A 5800 Series transmitter has been
tampered (cover removed).
A system trouble exists (RF
receiver, bell output, etc.).
SYSTEM LO This indicates that a low-battery
BAT
condition exists with the system’s backup
battery.
If the problem has been corrected, enter an
OFF sequence (Security Code + OFF) twice
to clear the display.
RCVR
SETUP
ERROR
This indicates that the system has more
wireless zones programmed than the
wireless receiver can support. If this is
not corrected, none of the zones in the
system will be protected. If additional
wireless zones are desired, use an
appropriate receiver.
MODEM
COMM
This indicates that the control is on-line
with a remote computer.
To the Installer
Regular maintenance and inspection (at least annually)
by the installer and frequent testing by the user are
vital to continuous satisfactory operation of any alarm
system.
Turning the System over to the User
Fully explain the operation of the system to the user by
going over each of its functions, as well as the User’s
Manual supplied.
The installer should assume the responsibility of
developing and offering a regular maintenance program
to the user as well as acquainting the user with the
proper operation and limitations of the alarm system
and its component parts. Recommendations must be
included for a specific program of frequent testing (at
least weekly) to ensure the system’s proper operation at
all times.
In particular, explain the operation of each zone
(entry/exit, perimeter, interior, fire, etc.). Be sure the
user understands how to operate any emergency
feature(s) programmed into the system.
9-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Having this information handy will make it easier for
us to serve you quickly and effectively.
Contacting Technical Support
PLEASE, before you call Technical Support, be sure
you:
You may contact Technical Support via Toll-Free Fax.
Please include your return fax number. You will receive
a reply within 24 hours.
•
•
•
READ THE INSTRUCTIONS!
Check all wiring connections.
Determine that the power supply and/or backup
battery are supplying proper voltages.
•
•
•
Verify your programming information where
applicable.
Verify that all keypads and devices are addressed
properly.
Note the proper model number of this product, and
the version level (if known) along with any
documentation that came with the product.
•
Note your customer number and/or company name.
Technical Support:.................................................... 1-800-645-7492 (8 a.m.-8 p.m. EST)
ATLIS-FAX FAXBACK Automated Fax Retrieval System:.................... 1-800-573-0153 or
.................................................................................................1-516-921-6704 / ext. 1667
World Wide Web Address: .......................................... http://www.honeywell.com/security
9-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
A
Regulatory Agency Statements
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
UL Installation Requirements
The following requirements apply to both UL Residential and UL Commercial Burglary installations:
•
•
•
•
All partitions must be owned and managed by the same person(s).
All partitions must be part of one building at one street address.
The audible alarm device(s) must be placed where it/they can be heard by all partitions.
The control cabinet must be protected from unauthorized access. This can be done by installing a tamper switch on
the cabinet door (not supplied with VISTA-40) or by installing a UL Listed passive infrared detector positioned to
detect cabinet access. Wire the selected device to any EOLR-supervised zone (Zone 1-8). Program this zone for day
trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour alarm response must be used
for multiple-partitioned systems.
•
Remote downloading and auto-disarming are not UL Listed features.
NOTE: UL Commercial Burglary installations require the attack resistant cabinet. The cabinet is included in the
VISTA-ULKT kit.
UL609 Grade A Local Mercantile Premises/Local Mercantile Safe & Vault
Use the following guidelines for a Grade A Local Mercantile Premises/Local Mercantile Safe & Vault installation:
•
•
•
All zones must be configured for EOLR supervision (✳41=0). Wireless sensors may not be used. If 4190WH RPMs
are used, set field ✳24 to “0” to enable tamper detection.
Attach a door tamper switch (supplied) to the VISTA-40 cabinet backbox. For safe and vault installations, a shock
sensor (not supplied) must also be attached to the backbox. (Also see SECTION 3: Installing the Control)
Wire an AB12 Grade A Bell/Box to the bell output. Bell wires must be run in conduit. Program the bell output for a
timeout of 16 minutes or longer timeout and for confirmation of arming ding. (Also see SECTION 3: Installing the
Control.)
•
•
Wire the VISTA-40 tamper switch and AB12 Bell/Box tamper switches to any EOLR-supervised zone (zones 1-8).
Program this zone for day trouble/night alarm (type 05) or 24-hour audible alarm (type 07) response. The 24-hour
alarm response must be used for multiple-partitioned systems.
Entry delays must not exceed 45 seconds, and exit delays must not exceed 60 seconds.
UL365 Police Station Connected Burglar Alarm
Follow the instructions for UL609 local installations given above.
For Grade A Service:
•
•
You may use the VISTA-40 dialer alone, or the 7720 Long Range Radio alone.
When using the dialer, program it to send Burglary Alarm, Low Battery, and Communicator Test reports. Field ✳27
must be set to “024” (or less).
•
If you are using the 7720, connect it to the VISTA-40 burglary/audible panic alarm trigger.
For Grade AA Service:
•
•
You must use a 7920SE Long Range Radio.
Connect the 7920SE to the VISTA-40 burglary/audible panic alarm trigger.
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
UL611/UL1610 Central Station Burglary Alarm
Follow the instructions for UL609 Local installations given above.
For Grade A Service:
•
•
You must use the VISTA-40 dialer with a 7720 Long Range Radio.
Connect the control’s burglary/audible panic alarm trigger (on J7 header) and the 659EN’s phone line monitor
output to the 7720. The 7720 will send a report to the central station when a telephone line fault condition is
detected.
•
•
Also connect the 7720’s radio fault output to one of the VISTA-40 EOLR-supervised zones (i.e., 1-8). Program this
zone for a trouble by day/alarm by night (type 05) or a 24-hour alarm (type 07, 08) response to radio faults.
Program the control’s dialer to send Burglary Alarm, Trouble, Opening/Closing, and Low Battery reports.
For Grade AA Service:
Follow the instructions for Grade A service, except use the 7920SE in place of the 7720.
California State Fire Marshal (CSFM) and UL Residential Fire Battery Backup
Requirements
The California State Fire Marshal and UL have regulations that require all residential fire alarm control panels to have
backup battery with sufficient capacity to operate the panel and its attached peripheral devices for 24 hours in the
intended standby condition, followed by at least 4 minutes in the intended fire alarm signaling condition.
The VISTA-40 can meet this requirement without using a supplemental power supply, provided that the panel’s outputs
(including the current drawn from the auxiliary power output terminals) are limited as shown below:
•
•
•
Output current is limited to 750mA maximum total auxiliary power, polling loop, and bell output current.
Maximum auxiliary current is 300mA (including polling loop current).
A 14AH battery is used. (Yuasa model NP7-12 recommended; use two connected in parallel.) A dual-battery harness
is provided with the 4100EOLR Resistor Kit (kit also contains EOL resistors having spade lug/heat shrink tubing
construction approved by UL and CSFM for fire zone usage). Both batteries fit inside the panel’s cabinet.
A-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A – Regulatory Agency Statements
FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems, disconnect the control panel by removing the plug from the
RJ31X (CA38A in Canada) wall jack. We recommend that you demonstrate disconnecting the phones on
installation of the system. Do not disconnect the phone connection inside the control panel. Doing so will
result in the loss of your phone lines. If the regular phone works correctly after the control panel has been
disconnected from the phone lines, the control panel has a problem and should be returned for repair. If
upon disconnection of the control panel, there is still a problem on the line, notify the telephone company that
it has a problem and request prompt repair service. The user may not under any circumstances (in or out of
warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized
service agency for all repairs.
FCC PART 68 NOTICE
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that
contains, among other information, the FCC registration number and ringer equivalence number (REN) for
this equipment. If requested, this information must be provided to the telephone company.
This equipment uses the following jacks:
An RJ31X is used to connect this equipment to the telephone network.
The REN is used to determine the quantity of devices that may be connected to the telephone line. Excessive
RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most,
but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices
that may be connected to the line, as determined by the total RENs, contact the telephone company to
determine the maximum REN for the calling area.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance
that temporary discontinuance of service may be required. If advance notice is not practical, the telephone
company will notify the customer as soon as possible. Also, you will be advised of your right to file a
complaint with the FCC if you believe necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures that could
affect the operation of the equipment. If this happens, the telephone company will provide advance notice in
order for you to make the necessary modifications in order to maintain uninterrupted service.
If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty
information. If the trouble is causing harm to the telephone network, the telephone company may request
that you remove the equipment from the network until the problem is resolved.
There are no user serviceable components in this product, and all necessary repairs must be made by the
manufacturer. Other repair methods may invalidate the FCC registration on this product.
This equipment cannot be used on telephone company-provided coin service. Connection to Party Line
Service is subject to state tariffs.
This equipment is hearing-aid compatible.
When programming or making test calls to an emergency number, briefly explain to the dispatcher the
reason for the call. Perform such activities in the off-peak hours, such as early morning or late evening.
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
CANADIAN EMISSIONS STATEMENTS
This Class B digital apparatus complies with Canadian ICES-003
NOTICE
AVIS
L’étiquette d’Industrie Canada identifie le
matériel homologué. Cette étiquette certifie que le
matériel est conforme aux normes de protection,
d’exploitation et de sécurité des réseaux de
télécommunications, comme le prescrivent les
documents concernant les exigences techniques
relatives au matériel terminal. Le Ministère
n’assure toutefois pas que le matériel fonctionnera
à la satisfaction de l’utilisateur. Avant d’installer
ce matériel, l’utilisateur doit s’assurer qu’il est
permis de le raccorder aux installations de
l’enterprise locale de télécommunication. Le
matériel doit également être installé en suivant
une méthode acceptée da raccordement. L’abonné
ne doit pas oublier qu’il est possible que la
conformité aux conditions énoncées ci-dessus
n’empêche pas la dégradation du service dans
certaines situations.
The Industry Canada Label identifies certified
equipment. This certification means that the
equipment meets telecommunications network
protective, operational and safety requirements as
prescribed in the appropriate Terminal Equipment
Technical
Requirements
document(s).
The
Department does not guarantee the equipment
will operate to the user’s satisfaction.
Before installing this equipment, users should
ensure that it is permissible to be connected to the
facilities of the local telecommunications company.
The equipment must also be installed using an
acceptable method of connection. The customer
should be aware that compliance with the above
conditions may not prevent degradation of service
in some situations.
Repairs to certified equipment should be
coordinated by a representative designated by the
supplier. Any repairs or alterations made by the
Les réparations de matériel nomologué doivent
être coordonnées par un représentant désigné par
le fournisseur. L’entreprise de télécommunications
peut demander à l’utilisateur da débrancher un
user
to
this
equipment,
or
equipment
malfunctions, may cause the telecommunications
company to request the user to disconnect the
equipment.
appareil
à
la suite de réparations ou de
modifications effectuées par l’utilisateur ou à
Users should ensure for their own protection that
the electrical ground connections of the power
utility, telephone lines, and internal metallic
water pipe system, if present, are connected
together. This precaution may be particularly
important in rural areas.
cause de mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit
s’assurer que tous les fils de mise à la terre de la
source
téléphoniques
d’energie
et
électrique,
des canalisations
de
lignes
d’eau
métalliques, s’il y en a, sont raccordés ensemble.
Cette précaution est particulièrement importante
dans les régions rurales.
Caution: Users should not attempt to make such
connections themselves, but should contact an
appropriate electric inspection authority, or
electrician, as appropriate.
Avertissement : L’utilisateur ne doit pas tenter
de faire ces raccordements lui-même; il doit avoir
racours à un service d’inspection des installations
électriques, ou à un électricien, selon le cas.
NOTICE: The Ringer Equivalence Number
(REN) assigned to each terminal device provides
an indication of the maximum number of
terminals allowed to be connected to a telephone
interface. The termination on an interface may
consist of any combination of devices subject only
to the requirement that the sum of the Ringer
Equivalence Numbers of all the devices does not
exceed 5.
AVIS : L’indice d’équivalence de la sonnerie
(IES) assigné à chaque dispositif terminal indique
le nombre maximal de terminaux qui peuvent être
raccordés à une interface. La terminaison d’une
interface téléphonique peut consister en une
combinaison de quelques dispositifs, à la seule
condition que la somme d’indices d’équivalence de
la sonnerie de tous les dispositifs n’excède pas 5.
A-4
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
B
Summary of System Commands
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
User Code
Commands
Add A User Code = User Code + 8 + New User Number + New User’s Code
Change a Code = User Code + 8 + User Number + New User’s Code
Delete a User’s Code = Your User Code + 8 + User Number to Be Deleted + Your Code
Again
View User Capability = User’s Code + [✳] + [✳]
Set Real-Time Clock (Installer, Master Only) = Code + [#] + 63
Programming
Commands
Site Initiated Download = User Code + [#] + 1.
Direct-Wire Download Enable = User Code + [#] + 5.
Enter Program Mode = Installer Code + 800.
Enter Interactive Program Mode = Installer Code + 800 + [#] + 93
Exit Program Mode = ✳99 or ✳98.
Event Logging
Commands
Event Log Display = Code + [#] + 60 (Installer or Master Only)
Event Log Print = Code + [#] + 61 (Installer or Master Only)
Clear Event Log = Code + [#] + 62 (Installer or Master Only)
Wireless System
Commands
House ID Sniffer Mode = Code + [#] + 2 (Installer Only)
Transmitter ID Test = Code + [#] + 3 (Installer Only)
Go/No Go Test = Code + 5 (Test Key)
Additional
Commands
Partition GOTO
GOTO Home Partition
Panics
User Code + [✳] + Partition Number 0-2.
User Code + [✳] + 0.
[✳] + 1 or A Key (Zone 95).
[✳] + [#] or B Key (Zone 99).
[#] + 3 or C Key (Zone 96).
Press 0 for 5 Seconds.
View Downloaded Messages
Display All Zone Descriptors
Display User Self Help
Press [✳] for 5 Seconds.
Hold Any Key for 5 Seconds.
Relay Device
Control Commands
Activate Relay Device as Programmed = User Code + [#] + 71.
Activate Relay Device as Programmed = User Code + [#] + 72.
Activate Relay Device Manually = User Code + [#] + 70.
Activate Access Relay for Current Partition = User Code + 0.
Access Control
Commands
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
B-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
C
Specifications
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
VISTA-40 CONTROL
Physical:
Standard Cabinet (included) 12 1/2" W x 14 1/2" H x 3" D
UL Cabinet (optional)
Electrical:
14 1/2" W x 18" H x 4.3" D (Included in the VISTA-ULKT kit)
Voltage Input:
From the 1361 Plug-In Transformer (use 1361CN in Canada) or 1361X10 transformer
(for X-10 installations) rated 16.5VAC, 40 VA.
Alarm Sounder Output:
Auxiliary Power Output:
Backup Battery:
10VDC-13.8VDC, 1.7 amps max. (UL1023, UL609 installations); 750mA less aux.
current draw (UL985 installations).
9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the
output must be UL Listed, and rated to operate in the above voltage range.
12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH)
recommended.
Standby Time:
4 hours min. with 750mA aux. load using 7 AH battery.
Circuit Protectors:
PTC circuit breakers are used on battery input to protect against reverse battery
connections and on alarm sounder output to protect against wiring faults (shorts).
A solid-state circuit breaker is used on auxiliary power output to protect against wiring
faults (shorts).
Digital Communicator
Formats Supported:
ADEMCO High Speed, ADEMCO 4 + 2 Express, ADEMCO Low Speed, ADEMCO
Contact ID, Sescoa and Radionics Low Speed
Line Seize:
Double Pole
0.7B
Ringer Equivalence:
FCC Registration No.:
AC398U-68192-AL-E
Remote Keypads
6139
6160
Physical:
Physical:
Width:
Height:
6.25 inches
Width:
Height:
7.437 inches
5.25 inches
1.312 inches
4.75 inches
1.25 inches
Depth:
Depth:
Electrical:
Electrical:
Voltage Input:
12VDC
100mA
Voltage Input:
12VDC
150mA
Current Drain:
Interface Wiring:
RED:
Current Drain:
Interface Wiring:
RED:
12VDC input (+) auxiliary
power
12VDC input (+) auxiliary
power
BLUE:
Not Used
BLUE:
Not Used
GREEN:
YELLOW:
BLACK:
Data to control panel
Data from control panel
GREEN:
YELLOW:
BLACK:
Data to control panel
Data from control panel
Ground and (-) connection from
supplemental power supply
Ground and (-) connection from
supplemental power supply
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
C-2
Download from Www.Somanuals.com. All Manuals Search And Download.
A P P E N D I X
D
Contact ID Event Codes
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
TABLE OF CONTACT ID EVENT CODES
Code
110
121
122
123
131
132
134
135
150
301
302
305
306
309
321
332
333
344
373
380
Definition
Code
381
382
383
384
401
403
406
407
408
409
411
441
570
602
606
607
621
625
626
Definition
Fire Alarm
Loss of Supervision (RF)
Loss of RPM Supervision
RPM Sensor Tamper
RF Transmitter Low Battery
O/C by User
Duress
Silent Panic
Audible Panic
Perimeter Burglary
Interior Burglary
Entry/Exit Burglary
Day/Night Burglary
24-Hour Auxiliary
AC Loss
Power-Up Armed/Auto-Arm
Cancel by User
Remote Arm/Disarm (Download)
Quick Arm
Keyswitch O/C
Low System Battery
System Reset
Callback Requested
Armed STAY
Program Tamper
Battery Test Fail
Bell 1 Trouble
Bypass
Communicator Test
Listen-In to Follow
Burglary Walk-Test
Event Log Reset
Poll Loop Short-Trouble
Expansion Module Failure
RF Jam
Time/Date Reset
Fire Loop Trouble
Trouble (global)
Time/Date Inaccurate
D-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
D-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
#93 Menu Mode Programming.................................... 4-2
#93 Menu Mode Programming Commands................. 4-3
12/24 Hour Type Stamp Format................................ 5-11
1361 ...................................................................3-24, C-1
1361X10 Transformer ...................................... 3-17, 3-24
24-hour Audible Alarm Type 07................................... 4-6
24-hour Auxiliary Alarm Type 08 ................................. 4-6
24-hour Silent Alarm Type 06...................................... 4-6
2-Wire Latching Glassbreak Detectors...................... 3-10
2-Wire Smoke Detectors ............................................. 3-7
333 PRM ..................................................................... 3-8
4100SM.............................................................. 3-19, 4-7
4100SM Serial Module................................................ 6-3
4146 .......................................................................... 3-18
4197 Polling Loop Extender ...................................... 3-12
4204 and 4204CF Relay Modules............................. 3-16
4208 Module Zone Assignment................................... 5-8
4285/4286 VIP Module.............................................. 3-20
4297 Polling Loop Extender ...................................... 3-12
4-Wire Smoke Detectors ............................................. 3-7
5800 Series Transmitters .......................................... 3-15
5800TM Module ........................................................ 3-15
5869 .......................................................................... 3-13
5881 RF Receivers.................................................... 3-13
5881ENHC ................................................................ 3-13
6139 ............................................................................C-1
6160 ............................................................................C-1
675 Ground Start Module.......................................... 3-17
685 Receiver ............................................................. 3-22
719 .............................................................................. 3-4
747 .............................................................................. 3-4
7720 .......................................................................... 3-19
7720ULF.................................................................... 3-19
7920SE...................................................................... 3-19
Alarm Code for Zones 25–32 .......................................5-6
Alarm Code for Zones 33–40 .......................................5-6
Alarm Code for Zones 41–48 .......................................5-6
Alarm Code for Zones 49–56 .......................................5-7
Alarm Code for Zones 57–64 .......................................5-7
Alarm Code for Zones 65–72 .......................................5-9
Alarm Code for Zones 73–80 .....................................5-10
Alarm Code for Zones 87–88 .......................................5-7
Alarm Code for Zones 89–99 .......................................5-7
Alarm Output Current Load ........................................3-26
Alarm Output Supervision ............................................3-4
Alarm Sounder Duration...............................................5-2
ALPHA PROG..............................................................4-3
Arm Stay and Time Set Report Codes (First Digit).....5-10
Arm Stay and Time Set Report Codes (Second Digit)5-10
Arm-Away Type 21.......................................................4-6
Arm-STAY Type 20 ......................................................4-6
Audio Alarm Verification Module ................................3-22
AUXILIARY OUTPUT ENABLE........................ 3-17, 3-19
Auxiliary Output Mode................................................5-10
Auxiliary Power Current Load.....................................3-26
B
BACK-UP BATTERY...................................................C-1
Battery Capacity Worksheet.......................................3-27
Battery Selection Table..............................................3-27
Battery Test..................................................................9-1
Burglary Alarm Communicator Delay...........................5-8
Burglary Trigger for Response Type 8 .........................5-3
Burglary Walk Test.......................................................9-1
Button RF (BR) Type 05..................................... 3-15, 4-6
C
A
Cabinet Lock ................................................................3-1
California State Fire Marshal (CSFM) ......................... A-2
Callback .......................................................................6-2
Callback Requested .....................................................6-1
CANADIAN EMISSIONS STATEMENTS.................... A-4
Changing a User Code.................................................8-4
Check Messages..........................................................9-3
Checksum Verification..................................................5-5
Chime on External Siren ............................................5-10
CIRCUIT PROTECTORS............................................C-1
Code + TEST [5] ..........................................................9-1
Cold Water Pipe.........................................................3-25
COMM FAILURE..........................................................9-3
Communication Defaults ..............................................4-4
Communicator Split Reporting Selection......................5-9
Compass Downloading Software ......................... 6-1, 6-3
Compatible 2-Wire Smoke Detectors...........................3-7
Compatible 4-Wire Smoke Detectors...........................3-7
Compatible 5800 Series Transmitters........................3-16
Compatible Alarm Indicating Devices...........................3-4
Compatible Glass Break Detectors ............................3-10
AAV ........................................................................... 3-22
AB12............................................................................ 3-1
ABB1031 ..................................................................... 3-4
AC Loss Keypad Sounding.......................................... 5-2
AC Outlet Ground...................................................... 3-25
Access Control ............................................................ 4-7
Access Control Commands......................................... B-1
Access Relay Number............................................... 5-11
Adding a User Code.................................................... 8-3
Adding an RF Key to a User Code .............................. 8-4
Addressing the Keypads.............................................. 3-3
ADEMCO 4+2 EXPRESS.....................................3-5, C-1
ADEMCO CONTACT ID..............................................C-1
ADEMCO HIGH SPEED..............................................C-1
ADEMCO LOW SPEED .......................................3-5, C-1
Agency Statements ..................................................... A-1
Alarm Code for Zones 01–08 ...................................... 5-6
Alarm Code for Zones 09–16 ...................................... 5-6
Alarm Code for Zones 17–24 ...................................... 5-6
In d ex-1
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
Compatible Polling Loop Devices.............................. 3-11
Confirmation of Arming Ding ....................................... 5-2
CONTACT ID EVENT CODES....................................D-1
Contacting Technical Support ..................................... 9-4
Control Unit Power Supply Load ............................... 3-26
Conventions Used in This Manual.................................. vi
CUSTOM INDEX......................................................... 4-3
EXPERT MODE ...........................................................4-3
External Sounders........................................................3-4
F
FCC Part 15 STATEMENT.......................................... A-3
FCC PART 68 NOTICE............................................... A-3
FCC REGISTRATION NO...........................................C-1
First Communication ....................................................6-2
First Test Report Time..................................................5-8
D
Data Encryption........................................................... 6-1
Data Field Descriptions ............................................... 5-1
Data Field Programming Mode.................................... 4-1
Daylight Saving Time Start/End Month...................... 5-11
Daylight Saving Time Start/End Weekend ................ 5-12
Deleting a User Code.................................................. 8-4
DEVICE PROG............................................................ 4-3
Dial Tone Detection..................................................... 5-5
Dial Tone Pause.......................................................... 5-4
Dialer Test................................................................... 9-1
DIGITAL COMMUNICATOR........................................C-1
DIP Switch Loop (DP) Type 07.................................... 4-6
Dip Switch Polling Loop Right Loop (PS) Type 08 ...... 4-6
Direct-Wire Downloading............................................. 6-3
Disable Download Callback....................................... 5-11
Disarm Type 22........................................................... 4-6
Download Command Enables..................................... 5-4
Download ID Number.................................................. 5-4
Download Phone Number ........................................... 5-4
Downloading................................................................ 6-1
Downloading Access Security ..................................... 6-1
Downloading Requirements ........................................ 6-1
Dual Reporting ............................................................ 5-5
Duress Codes Level 6 ................................................. 8-2
Duress Reporting ........................................................ 8-2
G
General Description......................................................1-1
Getting On-Line with a Control Panel...........................6-2
Global Arm ? ................................................................8-3
Go/No Go Test Mode ...................................................9-2
Grade A Mercantile Premises Listing...........................3-1
Grade A Mercantile Safe and Vault Listing ..................3-2
Grade A Service...................................................A-1, A-2
Grade AA Service.................................................A-1, A-2
Ground Start Module..................................................3-17
H
Hardwire and Optional Expansion Zones.....................1-1
Hardwired (HW) Type 01..............................................4-6
House ID Sniffer Mode...............................................3-15
I
ID Digit for Zones 01–08 ..............................................5-6
ID Digit for Zones 09–16 ..............................................5-6
ID Digit for Zones 17–24 ..............................................5-6
ID Digit for Zones 25–32 ..............................................5-6
ID Digit for Zones 33–40 ..............................................5-6
ID Digit for Zones 41–48 ..............................................5-6
ID Digit for Zones 49–56 ..............................................5-7
ID Digit for Zones 57–64 ..............................................5-7
ID Digit for Zones 65–72 ..............................................5-9
ID Digit for Zones 73–80 ............................................5-10
ID Digit for Zones 87–88 ..............................................5-7
ID Digit for Zones 89–99 ..............................................5-7
Ignore Expansion Zone Tamper...................................5-3
Installer (User 1) Code Level 0.....................................8-1
Installer Code...............................................................5-1
Installing RPM Devices ..............................................3-10
Installing The Control ...................................................3-1
Installing the Control's Circuit Board ............................3-2
Intelligent Test Report..................................................5-3
Interior w/Delay Type 10 ..............................................4-6
Interior, Follower Type 04 ............................................4-5
E
Earth Ground............................................................. 3-25
Enable 5800 RF Button Force Arm ........................... 5-11
Enable 5800 RF Button Global Arm.......................... 5-11
Enable Dialer Reports for Panics & Duress................. 5-8
Enable GOTO for this Partition.................................. 5-12
Enable J7 Triggers for Partition................................. 5-12
Enable Open/Close Report for Installer Code ............. 5-4
Enable Open/Close report for Keyswitch..................... 5-4
Entering Programming Mode....................................... 4-1
Entry Delay #1............................................................. 5-1
Entry Delay #2............................................................. 5-1
Entry Warning.............................................................. 5-8
Entry/Exit #1 Type 01.................................................. 4-5
Entry/Exit #2 Type 02.................................................. 4-5
Event Log .................................................................. 3-19
Event Log .................................................................... 1-2
Event Log Types ....................................................... 5-11
Event Logging Commands.......................................... B-1
Exit Delay #1 ............................................................... 5-1
Exit Delay #2 ............................................................... 5-2
Exit Delay Sounding.................................................. 5-10
Exiting the User Edit Mode.......................................... 8-4
K
Keypad Panic Enables.................................................5-2
Keypads .......................................................................2-1
Keyswitch ...................................................................3-18
Keyswitch Assignment .................................................5-2
In d ex-2
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Keyswitch Tamper..................................................... 3-18
Prevent Zone XX Bypass .............................................5-4
Primary Format.............................................................5-5
Primary Phone Number................................................5-4
Primary Subscriber’s Account Number.........................5-3
Printer Configurations ................................................3-19
Program Modes............................................................4-1
Programming................................................................4-1
Programming Commands ........................................... B-1
PROGRAMMING COMMANDS ...................................4-1
Programming Entry Errors............................................4-2
Programming Partition-Specific Data Fields.................4-2
Programming System-Wide Data Fields ......................4-2
L
LINE SEIZE.................................................................C-1
List of Figures..................................................................v
LO BAT........................................................................ 9-3
Long Range Radio to J7 Triggers ............................. 3-19
Low Speed Format (Primary) ...................................... 5-5
Low Speed Format (Secondary).................................. 5-5
M
Q
Manager Codes Level 2 .............................................. 8-1
Master Codes Level 1.................................................. 8-1
MODEM COMM ................................................... 6-1, 9-3
modems....................................................................... 6-1
Mounting The Control Cabinet .................................... 3-1
Multi-Access ? ............................................................. 8-3
Multiple Alarms............................................................ 5-2
Multiple Partition Access ............................................. 8-2
Quick Arm............................................................. 5-3, 8-1
R
RADIONICS LOW SPEED ..........................................C-1
Randomize AC Loss Report.........................................5-2
RCVR SETUP ERROR ................................................9-3
Real-Time Clock...........................................................7-1
Regulatory Agency Statements................................... A-1
RELAY PGM ................................................................4-3
Relay Timeout XXX Minutes ......................................5-11
Relay Timeout YYY Seconds.....................................5-11
Remote Keypad Sounder...........................................3-19
Reporting Formats........................................................3-5
Response Types for Zones 01–08 ...............................5-1
Response Types for Zones 09–16 ...............................5-1
Response Types for Zones 17–24 ...............................5-1
Response Types for Zones 25–27, 97, 95, 96,
N
No Alarm Response Type 23 ...................................... 4-6
Non-Alarm Report Codes (First Digit........................... 5-7
Non-Alarm Report Codes (Second Digit...................... 5-8
Non-UL Installations.................................................... 3-4
Normally Closed or EOLR (Zones 2-8)........................ 5-4
Number of Codes per Partition.................................. 5-12
Number of Partitions.................................................. 5-11
O
and 99 ......................................................................5-1
Response Types for Zones 28–32 ...............................5-9
Response Types for Zones 33–40 ...............................5-9
Response Types for Zones 41–48 ...............................5-9
Response Types for Zones 49–56 ...............................5-9
Response Types for Zones 57–64 ...............................5-9
Response Types for Zones 87–91 ...............................5-9
Restore Report Timing .................................................5-8
RF Receiver Supervision Check-in Interval..................5-9
RF System Installation Advisories..............................3-13
RF System Operation and Supervision......................3-13
RF Transmitter Check-in Interval .................................5-9
RF Transmitter Low Battery Reporting.........................5-9
RF Transmitter Low Battery Sound..............................5-9
Ring Count ...................................................................6-2
Ring Detection Count...................................................5-5
RINGER EQUIVALENCE............................................C-1
RJ31X ..........................................................................3-5
RJ31X jack.................................................................3-21
RLY VOICE DESCR.....................................................4-3
OC or OPEN CIRCUIT ................................................ 3-3
On-Line Control Functions .......................................... 6-2
Open/Close Reporting................................................. 8-2
Operator Access Levels .............................................. 6-1
Operator Codes Levels 3-5 ......................................... 8-1
Output Device Control Commands.............................. B-1
Output Devices.......................................................... 3-16
Overvoltage Protection................................................ 3-5
P
PA400.......................................................................... 3-4
PABX Access Code..................................................... 5-3
Partitioned System ...................................................... 2-1
Partitioning ........................................................... 1-1, 2-1
Perimeter Type 03....................................................... 4-5
Peripherals Devices..................................................... 1-1
Permanent Keypad Display Backlighting................... 5-10
Phone Module Access Code ....................................... 5-2
Polling Loop............................................................... 3-10
Polling Loop Current Draw ........................................ 3-26
Polling Loop Supervision........................................... 3-12
Power Failure .............................................................. 9-3
Power-Up in Previous State ........................................ 5-3
Prevent Fire Timeout................................................... 5-2
S
Secondary Format........................................................5-5
Secondary Phone Number...........................................5-4
Secondary Subscriber Account Number ......................5-8
Send Cancel If Alarm + Off ........................................5-11
In d ex-3
Download from Www.Somanuals.com. All Manuals Search And Download.
VISTA-40 Installation and Setup Guide
serial number devices................................................ 3-11
Serial Number Polling Loop (SL) Type 06................... 4-6
Serial Printer.............................................................. 3-20
SESCOA .....................................................................C-1
Sescoa/Radionics........................................................ 3-5
Sescoa/Radionics Select............................................. 5-5
Siren Driver ................................................................. 3-5
Smoke Power Reversal Module .................................. 3-8
Specifications ..............................................................C-1
Standard/Expanded Reporting Primary....................... 5-6
Standard/Expanded Reporting Secondary.................. 5-6
Standby Battery Size................................................. 3-27
Supervised Fire (Without Verification) Type 09........... 4-6
Supervised RF........................................................... 3-15
Supervised RF (RF) Type 03....................................... 4-6
Supervision Pulses for LRR....................................... 5-12
Supervisory and Restore Codes for Zones 01–16 ...... 5-6
Supervisory and Restore Codes for Zones 17–32 ...... 5-6
Supervisory and Restore Codes for Zones 33–48 ...... 5-7
Supervisory and Restore Codes for Zones 49–64 ...... 5-7
Supervisory and Restore Codes for Zones 65–80 .... 5-10
Supervisory and Restore Codes for Zones 87–99 ...... 5-7
Supplementary Power Supply..................................... 3-3
Suppress Transmitter Supervision Sound................. 5-10
Swinger Suppression .................................................. 5-8
System Commands ..................................................... B-1
System Communication............................................... 1-1
SYSTEM LO BAT........................................................ 9-3
System LoBat”............................................................. 9-1
System Messages ....................................................... 9-3
System Sensor A77-716B EOL Relay Module ............ 3-7
System Sensor MA 12/24D ......................................... 3-4
System Sensor P12575............................................... 3-4
UL609 Grade A Local Mercantile Premises/Local
Mercantile Safe & Vault........................................... A-1
UL611/UL1610 Central Station Burglary Alarm........... A-2
UL985 Household Fire or Household Fire/Burglary
Installations ..............................................................3-4
Unsupervised RF........................................................3-15
Unsupervised RF (UR) Type 04...................................4-6
Use Partition Descriptor .............................................5-12
User Access Codes......................................................8-1
User Code Authority Levels..........................................8-1
User Code Commands................................................ B-1
User Code Rules..........................................................8-2
Users............................................................................2-1
V
View Capabilities..........................................................8-1
VIP Module.................................................................3-20
VIP Module Phone Code..............................................5-2
VISTA-40 Current Load..............................................3-26
W
Wheelock AS-121575W ..............................................3-4
Wire Run Length/Gauge ..............................................3-3
Wireless Keypad Assignment.....................................5-10
Wireless Keypad Tamper Detect................................5-10
Wireless System Commands ...................................... B-1
Wireless Zone Expansion...........................................3-13
Wiring Devices to Zones 1-9 ........................................3-6
Wiring the Alarm Output...............................................3-4
Wiring the Keypads......................................................3-3
Worksheets to calculate the total current ...................3-26
World Wide Web Address............................................9-4
T
X
Telco Handoff.............................................................. 6-3
Telephone Line Connections....................................... 3-5
TELEPHONE OPERATIONAL PROBLEMS................ A-3
Test Report Interval..................................................... 5-3
Testing The System..................................................... 9-1
TouchTone or Rotary Dial ........................................... 5-3
TouchTone with Rotary Backup .................................. 5-9
Transformer Connections.......................................... 3-24
Transmitter Battery Life............................................. 3-16
Transmitter ID Sniffer Mode ........................................ 9-2
Transmitter Input Types............................................. 3-15
Transmitter Supervision............................................. 3-15
Trouble by Day/Alarm by Night Type 05...................... 4-5
Trouble Conditions ...................................................... 9-3
Trouble Messages....................................................... 9-3
Turning the System Over to the User.......................... 9-3
X-10............................................................................3-17
Y
Yuasa.........................................................................3-27
Z
Zone 5 Audio Alarm Verification.................................5-11
Zone 804....................................................................3-20
Zone 9 Fast/Slow Response ........................................5-2
Zone Defaults...............................................................4-4
Zone Index ...................................................................4-4
Zone Input Type Definitions .........................................4-6
Zone Number Designations..........................................4-4
ZONE PROG...........................................................vi, 4-3
Zone Response Type Definitions .................................4-5
Zone Type Restores for Zone Types 1-8 .....................5-7
Zone Type Restores for Zone Types 9, and 10............5-7
Zones ...........................................................................2-1
U
UL Installation Requirements ...................................... A-1
UL1023 Household Burglary Installations ................... 3-4
UL365 Police Station Connected Burglar Alarm.......... A-1
In d ex-4
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING!
THE LIMITATIONS OF THIS ALARM SYSTEM
While this System is an advanced wireless security system, it does not offer guaranteed protection against burglary, fire or
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a vari-
ety of reasons. For example:
•
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or
disconnect an alarm warning device.
•
Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work with-
out power. Battery-operated devices will not work without batteries, with dead batteries, or if the batteries are not put in
properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.
•
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the
signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path.
•
•
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not acti-
vate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the
Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may
not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not
sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side
of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor de-
tector, for example, may not sense a first floor or basement fire. Finally, smoke detectors have sensing limitations. No
smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by
carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable
materials, overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire
and/or location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to
allow all occupants to escape in time to prevent injury or death.
•
•
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their
installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams
of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion
or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows.
Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical
system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the
ambient temperature of the protected area approaches the temperature range of 90° to 105°F (32° to 40°C), the detection
performance can decrease.
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the
other side of closed or partly open doors. If warning devices are located on a different level of the residence from the bed-
rooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear
the warning if the alarm is muffled by noise from a stereo, radio, air conditioner or other appliance, or by passing traffic.
Finally, alarm warning devices, however loud, may not warn hearing-impaired people.
•
•
•
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or
temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect them-
selves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately.
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to
last as long as 20 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This
alarm system should be tested weekly to make sure all sensors and transmitters are working properly. The security keypad
(and remote keypad) should be tested as well.
Wireless transmitters (used in some systems) are designed to provide long battery life under normal operating conditions.
Longevity of batteries may be as much as 4 to 7 years, depending on the environment, usage, and the specific wireless device
being used. External factors such as humidity, high or low temperatures, as well as large swings in temperature, may all
reduce the actual battery life in a given installation. This wireless system, however, can identify a true low battery situation,
thus allowing time to arrange a change of battery to maintain protection for that given point within the system.
Installing an alarm system may make the owner eligible for a lower insurance rate, but an alarm system is not a substitute
for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and
continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm
systems owe it to themselves and their loved ones to learn about these developments.
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
Honeywell International Inc., 165 Eileen Way, Syosset, New York 11791, warrants its product(s) to be in
conformance with its own plans and specifications and to be free from defects in materials and workmanship
under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s)
not having a date stamp, for 12 months from date of original purchase unless the installation instructions or
catalog sets forth a shorter period, in which case the shorter period shall apply. Seller’s obligation shall be
limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is
proved not in compliance with Seller’s specifications or proves defective in materials or workmanship under
normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the
product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. For
warranty service, return product(s) transportation prepaid, to Honeywell Factory Service, 165 Eileen Way,
Syosset, New York 11791.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A
PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE
FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL
OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR
IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR
DAMAGE IS CAUSED BY THE SELLER’S OWN NEGLIGENCE OR FAULT.
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the
product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that
the product(s) will in all cases provide adequate warning or protection. Customer understands that a
properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or
other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not
occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER
SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS
BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS
HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING
UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN,
SELLER’S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF
THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST
SELLER.
This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s).
No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTES
Download from Www.Somanuals.com. All Manuals Search And Download.
165 Eileen Way, Syosset, New York 11791
Copyright © 2004 Honeywell International, Inc.
¬1ꢀꢁꢁꢂ9ꢃ+lꢄ
N7001V5 5/04 Rev A
Download from Www.Somanuals.com. All Manuals Search And Download.
|