Instructions
®
Dyna-Star HP Vent
Valve Kit
332519F
EN
Used with the Dyna-Star HP or HF Pump to reduce system pressure and allow injector to
reset. For professional use only.
Part No.: 77X540
Maximum Working Pressure: 3500 psi (241 bar, 24 MPa)
Important Safety Instructions
Read all warnings and instructions in this
manual and the Dyna-Star HP and HF Pump
instruction manual included with your unit. Save
all instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
Instructions
5. Loosen, remove and discard the 3 socket head cap
Vent Valve Installation
a
Reference numbers used in these instructions corre-
spond to Parts included in Kit and are provided on page
5. Parts identified with an alpha character are user pro-
vided or already installed components.
b
c
To ensure the correct pressure relief valve is used and
pressure settings are correct, always use new parts
included in your Vent Valve Kit for reassembly.
1. If unit has already been in service, relieve pressure
FIG. 3
Discard these parts according to state and local
codes for proper disposal. These parts will not be
used for reassembly.
2. Disconnect Dyna-Star HP or HF pump from main
power source.
3. Remove outlet tubing from port marked “0” on the
7. Grease o-rings (8) and install o-rings in vent valve
8
FIG. 4
a
Clean surface of the Dyna-Star pump outlet with a
clean dry cloth. Inspect pump surface for scratches or
nicks. A scratched surface can result in fluid leakage.
FIG. 2
4. Remove plug or inlet tubing from port marked “1” on
332519F
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Instructions
8. Install vent valve (1) to pump surface using the 3
vent valve tight to the surface of the pump to ensure
o-rings stay in place during installation.Torque
screws to 17-19 ft-lbs (23-26 N.m).
d
c
1
4
FIG. 7
12. Install other end of cable (d) to solenoid control
device.
FIG. 5
NOTE:
•
Cable (d) is available from Graco. See Accesso-
9. Install lubrication line to vent valve pump outlet port
•
•
Connector termination is a Deutsch DT-04-2P.
Solenoid inputs are not polarity dependent.
Voltage can be applied in either direction.
•
Solenoid should be activated when the pump is
running. See wiring diagrams in pump manual
for more details.
10
13. Reconnect pump to main power supply.
14. Test system to ensure proper operation.
FIG. 6
•
•
a plug (10).
inlet plumbing necessary to attach a fill pump.
NOTE:
•
•
For tube-in-tube pump models, the “1” inlet can
be used as a fill port.
For models equipped with a follower plate, with-
out a tube-in-tube, the “1” inlet deposits grease
on top of the follower plate.
4
332519F
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
Parts
2
Ref Description
Qty
1
2
3
4
8
9
MANIFOLD, electric vent valve
1
1
1
3
2
1
1
VALVE, cartridge, 24VDC
VALVE, pressure relief, 3500 psi
SCREW, cap, socket, M8 x 1.25
O-RING
9
8
PLUG, pipe, 1/8 in. npt
10 PLUG, 1/4 in. npt
1
Accessories
Part No. Description
24N402 CABLE, 6 ft, vent valve, 2 pin for vent valve
10
control
77X529 CABLE, power injector system only. Use
with 77X528
77X528 CABLE, power extension, 15 ft (4.6m), use
with 77X529
3
4
Technical Data
.
Vent Valve for Dyna-Star HP
US
Metric
24.1 MPa, 241 bar
Maximum working pressure*
Inlet/Outlet Sizes
3500 psi
Outlet (marked “0”)
3/8 in. npt(f)
3/8 in. npt(f)
Inlet (refill - marked “1”)
Pressure Relief Valve
Factory Set Pressure
Reset Pressure
Relief Rate**
4000 psi + 250 psi
27 MPa, 275 bar + 10%
80% of set pressure
0.1 gallons/minute @3500 psi
0.4 liters/minute @24.1 MPa. 241 bar
0.65 liters/minute
Solenoid Valve
Flow**
Up to gpm 0.2 gallons/minute,
3
40 in /minute
Wetted materials
Weight
Zinc plated steel, carbon steel, aluminum, fluoroelastomer, polyurethane
4.0 lbs
IP65K
1.8 kg
IP Rating
Solenoid Coil
24 VDC
Resistance (DC) (Ohms) @ 68°F (20°C) Initial Current Draw (Amps)
28.8 0.83
*Dyna-Star HP Pump Models are rated for 5000 psi (34.47 MPa, 344 bar) maximum working pressure, however,
when a vent valve is installed on the HP Pump, the maximum working pressure must be reduced to 3500 psi (24.1
MPa, 241 bar).
**Flow capability depends on viscosity, type of fluid, temperature, etc.
332519F
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
4.95 in.
(12.57 cm)
1.5 in (3.81 cm)
2.5 in.
(6.36 cm)
1.5 in.
(3.81 cm)
4.0 in.
(10.16 cm)
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 332519
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
August 2014
Download from Www.Somanuals.com. All Manuals Search And Download.
|