Fluke Thermometer 561R User Manual

Safety Information  
Battery Replacemant  
Warning  
A Warning identifies conditions and actions that pose hazards  
to the user. To avoid electrical shock or personal injury, follow  
these guidelines:  
Do not point laser directly at eye or indirectly off  
reflective surfaces.  
561R Infrared Thermometer  
Quick Reference Guide  
Battery door  
locking latch  
Before using the Thermometer inspect the case. Do not use  
the Thermometer if it appears damaged. Look for cracks or  
missing plastic.  
Replace the batteries as soon as the battery indicator (  
appears.  
Laser  
)
Do not use the Thermometer if it operates abnormally.  
Protection may be impaired. When in doubt, have the  
Thermometer serviced.  
Do not operate the Thermometer around explosive gas,  
vapor, or dust.  
Trigger  
Do not connect the optional external probe to live electrical  
circuits.  
To avoid a burn hazard, remember that highly reflective  
objects will often result in lower than actual temperature  
measurements.  
Do not use in a manner not specified by this guide or users  
manual or the protection supplied by the equipment may be  
impaired.  
AA  
Batteries  
(2)  
(+)  
Battery  
Cover  
Caution  
To avoid damaging the thermometer or the equipment under  
test protect them from the following:  
Display  
EMF (electro-magnetic fields) from arc welders, induction  
heaters, etc.  
Static electricity.  
Features  
Function Buttons  
Thermal shock (caused by large or abrupt ambient  
temperature changes- allow 30 minutes for the  
Thermometer to stabilize before use).  
Do not leave the Thermometer on or near objects of high  
temperature.  
The Thermometer includes:  
• Single-spot Laser Sighting  
• Backlit Display  
• Current Temperature Plus MIN, MAX, DIF Temperature  
Displays  
Thermometer Buttons  
Button  
Symbols  
• Easy Emissivity Selector  
• Type-K Thermocouple  
• Two AA Batteries  
Description  
Symbol  
Explanation  
Risk of danger. Important information. See Manual.  
Warning. Laser.  
Press  
and then press to toggle between the MIN,  
MAX, and DIF options.  
• Users Manual on CD  
The  
button is used to show the MIN, MAX, and DIF  
Conforms to requirements of European Union and  
European Free Trade Association (EFTA)  
functions in the secondary display, whichever was pressed  
most recently.  
Operating the Thermometer  
Do not dispose of this product as unsorted municipal  
waste. Contact Fluke or a qualified recycler for  
disposal.  
To measure temperature, pull and hold trigger. Release  
the trigger to hold a temperature reading. The  
thermometer turns off when no activity is detected for  
seven seconds.  
Selects the emissivity setting. You can toggle between LO  
(0.3), MED (0.7), or HI (0.95) using  
.
You may need  
Battery  
to adjust emissivity for shiny metalic objects.  
Chinese manufacturing mark for products  
manufactured in the Peoples Republic of China (PRC)  
PN 2797301 December 2006  
©2006 Fluke Corporation. All rights reserved. Printed in USA.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Edimax Technology Switch ES 5224RS+ User Manual
Everpure Water System CGT 10S User Manual
Excalibur electronic Motorized Toy Car 8628 User Manual
Fellowes Laminator Jupiter A3 User Manual
Fundex Games Games Jelly Bean Jumble User Manual
GE Monogram Dishwasher ZBD6890NII User Manual
GE Monogram Range JBP64 User Manual
GE Monogram Range ZDP486LDPSS User Manual
GE Washer Dryer EWA2000 User Manual
GE Water System GNPR40L User Manual