Caution: Changes or modifications not expressly approved by
the party responsible for compliance could void the user's
authority to operate the equipment.
Auto Shut-Off Feature
Precautions
One Year Limited Warranty
TE10R
TThe scale will automatically shut off after 3 minutes of nonuse
to conserve the battery. The auto-shut off feature can be
disabled to allow the scale to operate continuously. To disable
the auto-shut off feature:
This scale is engineered to give you years of satisfactory
service if you handle it carefully. Here are a few precautions:
This product is warranted against defects in materials or
workmanship for one (1) year from date of original purchase for the
original purchaser. It does not cover damages or wear resulting
from accident, misuse, abuse, or unauthorized adjustment and/or
repair. Should this product require service (or replacement at our
option) while under warranty, please pack the item carefully and
return it prepaid, along with receipt showing date of purchase and
a note explaining reason for return to:
Note: This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation. This equipment has been
tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful
interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more
of the following measures:
1. Always read instructions thoroughly to ensure that you have
the full benefit of all the unit's features.
Digital Portion
Control Scale
Leading the Way in Accuracy
1. While the scale is off, press and hold the “UNIT CONVERSION”
button.
2. While continuing to hold down the “UNIT CONVERSION”
button, also press and hold down the “ON/OFF” button.
3. The display will show “88888”, then “A-oF” The auto-off
feature is now disabled. Release the buttons.
4. To enable the auto-off feature again, repeat steps 1 and 2.
“A-on” will appear. The auto-off feature is now functional.
2. DO NOT immerse unit in water, as doing so will cause
damage to internal components and void the warranty. If
you spill liquid on it, dry it immediately with a soft, lint-free
cloth.
3. DO NOT clean the unit with an abrasive or corrosive
material. This may scratch the plastic parts and corrode the
electronic circuits.
4. DO NOT subject the units to excessive force, shock, dust,
temperature or humidity. This may result in malfunction,
shorter electronic life span, damaged battery and distorted
parts.
5. DO NOT tamper with the unit's internal components. Doing
so will invalidate the warranty on the units and may cause
damage. The unit contains no user-serviceable parts.
6. This scale is an extremely sensitive weighing device. To avoid
damage to the unit or the battery, do not store anything on
the scale.
7. Remove the battery if the scale will not be used for a long
period of time.
8. DO NOT dispose of batteries in fire. Disposing of this product
in fire could cause batteries to explode or leak. Remove the
battery if the unit will not be used for a long period of time.
®
Taylor Precision Products, Inc.
2220 Entrada Del Sol, Suite A
Las Cruces, New Mexico 88001 USA
Customer Service Phone: 1-800-225-4834
Customer Service Fax: 1-575-526-4347
Specifications
Platform: 8-1/16” x 5”, Stainless steel (TE10ROS 10” x 6.75”)
There are no expressed warranties except as listed above. This warranty
gives you specific legal rights, and you may also have other rights which
vary from state to state.
For additional product information, or warranty information in Canada
or elsewhere outside the USA, please contact us through
Power: (1) 9 Volt battery (not included) or AC adaptor
(included)
Dimensions: 8-1/16” x 7-3/4” x 2-1/4”
Weight: 2 lbs, 3 oz (TE10ROS 3lbs, 3oz)
Capacity: 10 lb x 1/8 oz
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
10 lb x 0.05 oz
©2013 Taylor Precision Products, Inc. and its affiliated companies, all
rights reserved. Taylor® and Leading the Way in Accuracy® are
registered trademarks of Taylor Precision Products, Inc. and its affiliated
companies. All rights reserved.
160 oz x 0.05 oz
-Consult the dealer or an experienced radio/TV technician for
help.
5000 g x 1 g
Resolution:0 to 10 lbs by 1/8 oz increments
0 to 10 lbs by 0.05 oz increments
0 to 5000 g by 1 g increments
Accuracy: oz mode, +/-10 division
g mode, +/-10 division
Made to our exact specifications in China.
NOT LEGAL FOR TRADE
Instruction Manual
TE10R - 11.13WC
Thank you for purchasing a Taylor® Digital Portion Control Scale. Your
scale is an example of superior design and craftsmanship. In order to
optimize its function, be sure the read this instruction manual carefully
before use. Keep instructions handy for future reference.
General Operation (continued)
Main Features (continued)
• ON/OFF Button
When pressed, turns the scale “ON” or “OFF”.
• Backlit Display
Will illuminate when weight is added or removed from
platform. Press and Hold “ TARE ” to turn On/Off backlight
function.
• Moisture Resistant
Components are sealed for resistance to moisture.
• Auto Shut Off
Scale powers off after 3 minutes of nonuse.
• Low Battery Indicator
Appears on LCD screen when battery is low.
• Overload Signal
Warning appears when weight is at 10% above the scale's
rated capacity, even after tare up to 50% of capacity (in
pound mode).
Battery Installation
General Operation
The Digital Portion Control Scale operates with a rechargeable
battery (included). To install and charge the battery:
1. Remove the battery compartment door on the bottom of the
scale.
POWER
Tare capability example: On a 10 pound scale (TE10), a load of 5 lbs
(50%) can be tared out. Once tared out, an added weight of 11 lbs (full
capacity plus 10%) can still be weighed without causing an overload
condition.
To turn the scale on, press the button marked “ON/OFF”. The display
will first show “88888” followed by “
”. To turn the scale off, push
Description of Parts
the “ON/OFF” button. The scale will remember the unit mode last
If a load that exceeds 50% of the scale's capacity is tared out, the
additional weight that can be measured will be reduced accordingly.
shown, and this unit will display when the scale is turned on again.
Ounces
Display
Hold
Kilogram
Display
Pound
Grams
Display
2. Plug the male connector of the rechargeable battery onto the
female connector, which is located in the battery compartment.
3. Place the rechargeable battery into the battery box.
4. Replace the battery door.
Hold
Button
On/Off
Button
Display
Display
UNIT CONVERSION
HOLD OPERATION
Press the Unit Conversion Button to switch from fractional ounces to
decimal ounces to grams to ounces. When the scale is turned off, it
will remember the unit mode last shown and will turn-on in that mode.
HOLD
NET
The “HOLD” function may be used to lock the weight on the display for
ten (10) seconds, even after the load is removed from the platform.
g
o
z
k
g
lb
5. To charge the battery, insert the connector plug of the adaptor
into the jack at the back of the scale. Plug the other end of the
adaptor into the proper electrical outlet. A red LED on the side of
the scale will light up, indicating the battery is charging. When the
LED light changes to green, the battery is completely charged.
6. Allow at least 12 hours for the scale to charge completely. The
scale will then operate continuously for approximately 14 hours.
7. The battery life cycle is approximately 500 recharges. If the scale
does not function properly after at least 12 hours of charging, the
battery may need to be replaced. The scale will still operate on
adaptor power if the battery is not charged.
To use the hold function, press the “HOLD” button. A small triangle will
appear in the upper left corner of the display next to the word “hold”,
indicating the hold function is turned on. This triangle and the “hold”
function will remain in place until the “HOLD” button is pressed again.
This pressing of the “HOLD” button a second time will cancel the “hold”
function, and the triangle will disappear from the display. While the
scale is in “HOLD” mode:
WEIGHING
When the display shows “0”, the scale is ready to weigh an object. If
the object exceeds the capacity of the scale by more than 10%, the
display will show “Err” (for error). Until the overload condition is
reached, additional objects may be placed on the platform. The
display will show the sum of the weights of all the objects. When one
of multiple objects is removed from the platform, the weight of the
remaining objects will display.
Scale Stable
Display
LCD
Display
LED
Indicator
Tare / Light
Button
Unit Conversion
Button
Place a load on the platform. When the weight is locked in, the triangle
will begin to flash. When the load is removed from the platform, the
display will continue to show the weight for ten seconds. After the ten
second period is up, the triangle will stop flashing, and the display will
show “0”. If the load is not removed from the platform, the triangle will
continue to flash. The ten second “hold” period will begin once the
load is finally removed from the platform.
Main Features
• LCD Screen
1.0” digits display weight.
• Hold Button
8. To purchase a new rechargeable battery (model TERBAT), please
contact customer service at 1-800-225-4834.
9. There is also an AC adaptor included with this scale and can be
used in place of the Rechargeable Battery.
TARE OPERATION
To tare (zero out) a load on the platform (example: the weight of a
container), press the “TARE” button. The display will show the value
“0”.
When pressed, the weight will display for ten seconds, even
Before You Begin
after the weight is removed.
During the “TARE” mode, a new item can be added to the platform.
The display will show the sum of the weights of the added items.
Another item may be added, if desired. The display will show the sum
of all additional item weights above and beyond the tared out load.
During the ten (10) second period, the load can be tared out, causing
the display to show “0”. And additional load will be displayed and held
for another ten second period, etc.
NOTE: please recycle or dispose of batteries per local regulations.
1. Remove the scale from its box, along with its platform
• Unit Conversion Button
assembly and the adaptor.
When pressed, converts the weight display from fractional oz
WARNING: Batteries may pose a choking hazard. As with all small items,
do not let children handle batteries. If swallowed, seek medical
attention immediately.
2. Install the platform assembly onto the scale by matching the
plastic posts of the platform assembly with the mating holes
on the top of the scale (no special orientation is required).
to decimal oz to grams.
If the “HOLD” button is pressed again, the scale will revert to its normal
• Tare Button
TARE CAPABILITY
operating mode.
When pressed, the scale reading returns to zero. Additionally,
it can be used to offset the weight of a container or other
object up to 50% of the scale's capacity.
A load of up to 50% of the scale's capacity can be tared out, while still
allowing the weighing of an additional object, up to the full capacity
of the scale.
PRECAUTION: Do not dispose of batteries in fire. Batteries may explode
or leak. Remove the batteries if the scale will not be used for a long
period of time.
When the scale turns off, the hold function is cancelled. When the scale
is turned on again, it will be in normal operating mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
|