1. INTRODUCTION  
Thank you for purchasing PLANET Serial over Fast Ethernet Media Converter – ICS-10x series. Terms of “Serial Media  
Converter” means the products mentioned titled in the cover page of this User’s manual  
1.1 Package Contents  
Open the box of the Serial Media Converter and carefully unpack it. The box should contain the following items:  
Check the contents of your package for following parts:  
Serial Media Converter x1  
CD-ROM user's manual x1  
Quick installation guide x1  
External 5VDC / 2.5A power adapter x 1  
If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the  
original packing material, and use them against to repack the product in case there is a need to return it to us for repair.  
1.2 How to Use This Manual  
This Media Converter User Manual is structured as follows:  
ƒ
ƒ
Section 2, Installation  
It explains the functions of ICS-10x and how to physically install the ICS-10x.  
Section 3, Management  
The chapter explains how to manage the converter by Web interface.  
ƒ
ƒ
Section 4, Web Configuration  
It contains information about the Smart function of ICS-10x.  
Section 5, Software VCOM Utility  
It explains the software VCOM how to use with the operation Virtual COM.  
ƒ
Appendices  
It contains cable information of ICS-10x.  
-1-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
1.3 Product Description  
The Web-Smart ICS-10x series Media Converter / Device Server provide to converts Serial RS-232 / RS-422 / RS-485  
communication interface over Fast Ethernet networking. There are RJ-45/SC connectors and  
single-mode/multi-mode media for your needs. Ethernet signal that allows two types of segments to connect easily,  
efficiently and inexpensively. This converter can be used as a stand-alone unit or as a slide-in module to the PLANET  
Media Converter Chassis (MC-700, MC-1000 and MC-1500). It’s time saving expense for user and SI, no need to  
replace the existing Serial equipment and software system.  
It extends the distance of deploying Serial equipments and hosts. The selectable fiber-Optic wires on the basis of  
distance are flexibly provided. Therefore, this product will perfectly satisfy the diverse demands while providing reliable  
and efficient network solutions based on the distance and budgets of installation.  
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a  
TCP/IP networking immediately. Each Web-Smart converter is able to manage through the Web Interface. The powerful  
Web-Smart Media Converter supports Application mode, Serial operation mode connect alarm and IP address, etc.  
Management function helps reduce the amount of valuable time that a network administrator spends detecting and  
locating network problems, otherwise it requires visual inspection of cabling and equipment. Multiple connection options  
for large networking environment are available as well.  
1.4 Applications  
Access Control System – traditional installation  
Most of the enterprise and government use access control plate and Mifare or RFID to authorize the entrance identity.  
With traditional deploy, access control machine use RS-232 or RS-485 serial interface and cables connect to login server.  
With connection to ICS-10x Serial over Fast Ethernet Converter, the access control machine is able to be extend over  
longer distances via fiber optical interface. The distance can be up to 20km in a local range. Or the ICS-10x can be linked  
to a xDSL router to get the internet access capability; the access control can be set and monitored over the internet.  
Figure 1-1 Serial Converter for Access Control System application  
-2-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Process Control  
To monitor, configure and manage the Robot conveyer including other machines in a manufacturing, PLC (Programmable  
Logical Control) is required. The PLC is used to drive above the manufacturing machines process. The ICS-10x can be set  
to TCP Server mode and connect the PLC. The administrator can configure and set command settings through Fast  
Ethernet intranet to control the PLC, the administrator and workstation. There is no need to be always sets by the side of  
the I/O machine.  
Figure 1-2 Serial Converter for factory PLC application  
RTU Data Collect – UDP Mode  
Connect with RTU (Remote Terminal Unit) to collect and monitor the data of waves, signal and power utilization. ICS-10x  
can be used to set-up UDP mode and send data over Fast Ethernet to Local server or over internet to remote server  
automatically.  
Figure 1-3 Serial Converter for factory RTU application  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Surveillance motion control – Pair Connection Mode  
Using pair connection along with fiber optical patch cord, the ICS-10x extend RS-232/RS-485 interfaces distance from  
surveillance and scanner to the control keyboard/joystick which is installed in the remote monitor center.  
Figure 1-4 Serial Converter for distance extend application  
1.5 Product Features  
Serial Interface  
One RS-232/422/485 port to one 10/100Base-TX or 100Base-FX Media Converter  
Cost effective solution for RS-232 to Ethernet application  
Supports RS-232, 4-wire RS-422 or 2/4-wire RS485 operation  
Asynchronous serial data rates up to 921600b/s  
Ethernet Interface  
Complies with IEEE 802.3, IEEE 802.3u 10/100Base-TX, 100Base-FX standard  
Supports auto MDI/MDI-X function on RJ-45 Port  
Choice of fiber-connector from SC, multi-mode / single-mode fiber  
Smart Functions  
Standard TCP/IP interface and versatile operation modes  
Software Protocol Support ARP, ICMP,TCP/IP, UDP, HTTP server, DHCP client, Telnet server/client  
Built-in IP-Base Web interface for remote management  
Serial Operation mode selected via Web management  
Pair Connection mode for connecting two serial devices over a network  
PLANET Smart Discovery utility automatically finds xxx devices on the network  
Firmware upgrade via HTTP protocol  
Hardware  
Compact size for easy Installation:  
¾
Standalone - Wall mountable or DIN-Rail mounting (Optional accessory)  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
¾
Co-work with PLANET MC family Media Chassis ( MC-700/1000R/1500)  
LED indicators for easy network diagnose  
Reset Button at the front panel for reset to factory default  
1.6 PRODUCT SPECIFICATION  
Products  
ICS-100  
ICS-102  
ICS-102S15  
Hardware Specification  
Interface  
RS-232 / RS-422 / RS-485  
3-in-1 DB9  
Connector  
Baud rate  
110 to 921600bps  
Character Bits 5,6,7,8  
Parity type  
Stop Bit  
1,2  
Serial Port  
None, Even, Odd  
None, RTS/CTS, Xon/Xoff  
Flow Control  
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND  
RS-422: Tx+, Tx-, Rx+, Rx-, GND RS-485 (2-wire): Data+, Data-  
RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-  
Signals  
IEEE 802.3 10Bas-T  
Standard  
IEEE 802.3u 10/100Base-TX, 100Base-FX  
Connector  
Fiber Mode  
RJ-45  
-
SC  
Multi-Mode  
Full-Duplex  
2km  
Single-Mode  
Full-Duplex  
15km  
Ethernet Port  
Transmission  
Mode  
Full-Duplex / Half-Duple  
Distance  
100m  
-
Optical  
1300nm  
1310nm  
Wavelength  
50/125μm or  
9/125μm single-mode  
Cable  
Twisted-pair  
62.5/125μm  
cable  
multi-mode fiber cable  
Protection  
LED Indicators  
Built-in 1.5KV magnetic isolation  
System: Power  
TP or Fiber Port: Link / Active  
Serial Port: Link / Active  
Web Management  
Management  
PLANET VCOM Utility  
PLANET Smart Discovery Utility  
TCP Server  
TCP Client  
UDP Client  
Operation Mode  
Virtual COM  
Telnet Server  
Pair Connection – Remote (Slave)  
Pair Connection – Local (Master)  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Dimension (W x D x H)  
Weight  
97 x 70 x 26mm  
200g  
Power Supply  
Power Consumption  
Mechanical  
External Power Adaptor 5V DC / 2A max.  
5.5 Watts (maximum)  
Metal  
Operating Temperature: 0~50 Degree C  
Storage Temperature: -10~70 Degree C  
Humidity: 10%~90% RH (operating)  
5%~90% RH (Storage)  
Environment  
Emissions  
FCC Class A, CE Certification Class A  
IEEE 802.3 10Base-T  
Standards  
IEEE 802.3u 100Base-TX / 100Base-FX  
EIA/TIA RS-232/422/485  
Regulatory Approval  
RoHS  
Compatible Media Converter  
Chassis  
MC-700 / 1000R / 1500  
Note.  
Reset Button at the rear panel for reset to factory default  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
2. INSTALLATION  
This section describes the hardware features and installation of the ICS-10X’s components on the desktop or shelf. For  
easier management and control of the ICS-10x, familiarize yourself with its display indicators, and ports. Front panel  
illustrations in this chapter display the unit LED indicators. Before connecting any network device to the Serial Media  
Converter, please read this chapter completely.  
2.1 Hardware Description  
2.1.1 Product Layout  
Figure 2-1 to Figure 2-4 show layout and front panel of ICS-10X.  
ICS-100 – RS-232 / RS-422 / RS-485 over 10/100Base-TX  
Figure 2-1 ICS-100 panel layout  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Figure 2-2 PLANET ICS-100 Front Panel  
ICS-102 / ICS-102S15 – RS-232 / RS-422 / RS-485 over 10/100Base-FX  
Figure 2-3 ICS-102 / ICS-102S15 panel layout  
Figure 2-4 PLANET ICS-102 Front Panel  
-8-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
2.1.2 LED Indicators  
LED  
Color  
Function  
PWR  
Green  
Lights to indicate that the Converter is powered on.  
To indicate that the Fast Ethernet Port is successfully connecting to  
the network at 10Mbps or 100Mbps  
Lights  
TP or Fiber  
Serial  
Green  
Green  
Blinks To indicate the Fast Ethernet Port is receiving or sending data  
Lights To indicate that the UART Port is connected successfully  
Blinks To indicate the UART Port is receiving or sending data  
2.1.3 DB9 Pin Define  
DB9 Pin Define for RS-232 / RS-422 / RS-485  
RS-422/485  
4-wire  
RS-485  
2-wire  
DB9-PIN  
RS-232  
1
2
3
4
5
6
7
8
9
DCD  
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
CTS  
RI  
RX-  
Data B(-)  
Data A(+)  
TX-  
RX+  
TX+  
2.1.4 ICS-10X Rear Panel  
The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2.5A.  
ICS-10x series  
Figure 2-5 Rear Panel of ICS-10x  
1.  
2.  
The device is a power-required device, it means, it will not work till it is powered. If your  
networks should active all the time, please consider using UPS (Uninterrupted Power Supply)  
for your device. It will prevent you from network data loss or network downtime.  
Power  
Notice:  
In some area, installing a surge suppression device may also help to protect your Media  
Converter from being damaged by unregulated surge or current to the converter or the power  
adapter.  
-9-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
To press and release the RESET button. The ICS-10X will back to the factory default mode. Be sure that  
you backup the current configuration of ICS-10X; else the entire configuration will be erased when  
pressing the “RESET” button.  
Press and release the RESET button shortly, the device will be rebooted.  
Press the RESET button more than 10 seconds, the device will back to the factory default  
mode; the entire configuration will be erased.  
2.2 Install the Converter  
This section describes how to install your ICS-10X Web Smart Media Converter and make connections to the converter.  
Please read the following topics and perform the procedures in the order being presented. The hardware installation of  
PLANET ICS-10X Web Smart Media Converter do not need software configuration. To install your ICS-10X on a desktop  
or shelf, simply complete the following steps.  
2.2.1 Stand-alone Installation  
To install an ICS-10X stand-alone, on a desktop or shelf, simply complete the following steps:  
Step 1: Turn off the power of the device/station in a network to which the ICS-10X will be attached.  
Step 2: Ensure that there is no activity in the network.  
Step 3: Attach RJ-45 / SC Fiber cable from the ICS-10X to the network.  
Step 4: Attach RS-232/RS-485 cable from the ICS-10X to the want to connect devices.  
Step 5: Connect the 5VDC power adapter to the ICS-10X and verify that the Power LED lights up.  
Step 6: Turn on the power of the device/station; the PWR LED (Green) should light when all cables are attached.  
Figure 2-6 ICS-100 stand alone installation  
-10-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Figure 2-7 ICS-102 / ICS-102S15 stand alone installation  
Please refers to APPENDIX-A for detailed wiring information of the ICS-10X.  
To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the  
converter.  
2.2.2 Chassis Installation and Rack Mounting  
To install the Media Converter in a 10-inch or 19-inch with standard rack, follow the instructions described below.  
Step 1: Place your ICS-10X on a hard flat surface, with the front panel positioned towards your front side.  
Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis.  
Figure 2-8 Insert a Media Converter into an available slot  
Step 3: Attach a rack-mount bracket to each side of the Chassis with supplied screws attached to the package.  
-11-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Step 4: After the brackets are attached to the chassis, use suitable screws to securely attach the brackets to the rack, as  
shown in Figure 2-2.  
Step 5: Precede with the steps 4 and steps 5 of session 2.2.1 Stand-alone Installation to connect the network cabling  
and supply power to your converter.  
You must use the screws supplied with the mounting brackets. Damage caused to the parts by using  
incorrect screws would invalidate your warranty.  
Figure 2-9 Mounting the Chassis in a Rack  
-12-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
3. MANAGEMENT  
This chapter describes how to manage the ICS-10X. Topics include:  
- Overview  
- Management methods  
- Assigning an IP address to the ICS-10X  
- Logging on to the ICS-10X  
3.1 Overview  
This chapter gives an overview of converter management. The ICS-10X provides a simply WEB browser interface.  
Using this interface, you can perform various converter configuration and management activities, including:  
System  
Network Configuration  
Operation Mode  
Serial Port Configuration  
Please refer to the following Chapter 4 for more details.  
3.2 Requirements  
Network cables.  
For ICS-100: Use standard network (UTP) cables with RJ45 connectors.  
For ICS-102 / ICS-102S15: Use Multi-mode or Single Mode fiber patch cord with SC connectors.  
Subscriber PC installed with Ethernet NIC (Network Card)  
Workstations of subscribers running Windows 98/ME, NT4.0, 2000/2003/XP, MAC OS X or later, Linux, UNIX or  
other platform compatible with TCP/IP protocols.  
Above PC installed with WEB Browser, such as Microsoft Internet Explore or Mozilla Firefox  
It is recommended to use Internet Explore 6.0 or above to access Serial Media  
Converter.  
-13-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
3.3 Management Methods  
The way to manage the ICS-10X:  
- Web Management via a network or dial-up connection  
3.3.1 Web Management  
The PLANET Web-Smart Media Converter provides a built-in browser interface. You can manage the ICS-10X remotely  
by having a remote host with web browser, such as Microsoft Internet Explorer, Netscape Navigator or Mozilla Firefox.  
Using this management method:  
The ICS-10X must have an Internet Protocol (IP) address accessible for the remote host.  
Figure 3-1 Web Management over Ethernet  
3.3.2 Login the Media converter  
Before you start configure the ICS-10X, please note the ICS-10X is configured through an Ethernet connection, make sure  
the manager PC must be set on same the IP subnet address.  
For example, the default IP address of the ICS-10X is 192.168.0.100, then the manager PC should be set at 192.168.0.x  
(where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0.  
1.  
2.  
Use Internet Explorer 6.0 or above Web browser. Enter IP address http://192.168.0.100 (the factory-default IP  
address) to access the Web interface.  
When the following login screen appears, please enter the default username and password (default user name and  
password is "admin"). Press Login to enter the main screen of ICS-10X. The login screen in Figure 3-1 appears.  
Default IP Address: 192.168.0.100  
Default Account: admin  
Default Password: admin  
-14-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Figure 3-2 Login screen  
1. For security reason, please change and memorize the new password after this first setup.  
2. Only accept command in lowercase letter under web interface.  
-15-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4. WEB CONFIGURATION  
The ICS-10X Web Smart Media Converter provide Web interface for Converter smart function configuration and make the  
Converter operate more effectively - They can be configured through the Web Browser. A network administrator can  
manage and monitor the ICS-10x from the local LAN. This section indicates how to configure the Media Converter to  
enable its smart function.  
4.1 Main Menu  
After a successful login, the main screen appears, the main screen displays the converter Welcome page. The screen in  
Figure 4-1 appears.  
Figure 4-1 Web Main screen  
As listed at the left of the main screen, the configurable smart functions are shown as below:  
System –  
Check the hardware, software version and System MAC address and IP address  
of the converter. And the password changed firmware upgrade / Factory default /  
system reboot.  
Network Configuration-  
Setup the IP address of the converter.  
Operation Mode –  
Setup the serial port mode: “TCP server”, “TCP client”, “UDP client”, “Virtual  
COM”, “Telnet Server”, “Pair Connection – Remote (Master)” and “Pair  
Connection – Remote (Slave)”.  
Setup the serial port value  
Serial Port Configuration-  
-16-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.2 System  
4.2.1 System Information  
The System Information page provides information for the current device. System Info page helps a network manager to  
identify the versions and IP Address etc. The screen in Figure 4-2 appears.  
Figure 4-2 System Information screen  
The page includes the following fields:  
Specifies the device Model Name.  
Model Name  
Software Version  
MAC Address  
IP Address  
The current software version running on the device.  
Specifies the device MAC address.  
The current IP Address of the device. The IP Address could be manual assigned.  
The factory default value is 192.168.0.100.  
The current IP Subnet Mask setting on the device. The factory default value is  
255.255.255.0.  
Subnet Mask  
Gateway  
The default gateway for the IP interface. The factory default value is  
192.168.0.254.  
The current IP Subnet Mask setting on the device.  
Show the current serial port operation mode.  
System Name  
Current Operation  
Mode  
-17-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.2.2 Password Setting  
This function provides administrator to secure Web login. The screen in Figure 4-3 appears.  
Figure 4-3 Password Setting screen  
The page includes the following configurable data:  
Login Name  
Displays the user name.  
New Password  
Specifies the new password. The password is not displayed. As it entered an “y”  
corresponding to each character is displayed in the field.  
(The maximum length is 15 characters)  
Confirm Password  
This confirms the new password. The password entered into this field must be  
exactly the same as the password entered in the Password field.  
After change the default password, if you forget the password. Please press and release the “Reset”  
button in the front panel of ICS-10X, the current setting will be lost and the ICS-10X will restore to the  
default mode.  
-18-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.2.3 Firmware upgrade  
The Firmware Upgrade page contains fields for downloading system image files from the Local File browser to the  
device. The screen in Figure 4-4 appears.  
Figure 4-4 Firmware Upgrade screen  
To open Firmware Upgrade screen perform the folling:  
2. Click System -> Firmware Upgrade then click Load.  
3. The Firmware Upgrade screen is displayed as in Figure 4-5.  
Figure 4-5 Firmware Upgrade screen  
-19-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4. Then the “Firmware Upgrade Mode” displayed as in Figure 4-6.  
Figure 4-6 Firmware Upgrade screen  
Click the “Browse” button of the main page, the system would pop up the file selection menu to choose firmware.  
Figure 4-7 Windows file selection menu popup  
5. Select on the firmware then click “Upgrade”. The firmware upgrade may take 60 seconds.  
Do not power off the converter until the update progress is complete.  
Do not quit the Firmware Upgrade page without press the “Upgrade” button - after the image is  
loaded. Or the system won’t apply the new firmware. Users have to repeat the firmware  
upgrade processes again.  
-20-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4.2.4 Factory Default  
The Factory Default can reset the ICS-10x back to the factory default mode. Be aware that the entire configuration will be  
reset, and the IP address of the ICS-10x will be set to “192.168.0.100”. The screen in Figure 4-8 appears.  
Figure 4-8 Factory Default progress screen  
4.2.5 System Reboot  
The System Reboot can restart the ICS-10x. The screen in Figure 4-9 appears.  
Figure 4-9 System Reboot progress screen  
-21-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.3 Network Configuration  
This function allows setting the value for network configuration. The value is DHCP client, IP address, Subnet Mask,  
Gateway, DNS and system name. Press the “Apply” button to set the value. The screen in Figure 4-10 appears.  
Figure 4-10 Network Configuration screen  
The page includes the following configurable data:  
DHCP Client  
Disable or enable the DHCP function.  
When DHCP Client is set to “Enable”, the ICS-10x will send a DHCP request to the  
DHCP server in the network. Once the DHCP Server get the request, it will assign a  
dynamic IP address, netmask and gateway to the ICS-10x.  
The factory default setting is “Disable”  
Assign the converter IP Address.  
IP Address  
Subnet Mask  
Gateway  
DNS  
The factory default value is 192.168.0.100  
Assign the converter Subnet Mask.  
The factory default value is 255.255.255.0  
Assign the converter gateway.  
The factory default value is 192.168.0.254  
DNS is the way that Internet domain names are identified and translated into IP  
addresses. A domain name is an alphanumeric name, such as planet.com, that it is  
usually easier to remember. Assign the DNS server IP address.  
System Name  
Allow set value for system name. (The maximum length is 15 characters).  
-22-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
When DHCP Client is set to Enable, the IP Address, Subnet Mask, Gateway and DNS fields are not  
allow to be changed.  
If the Media Converter is set to DHCP Client enable, you can use PLANET Smart Discovery or  
PLANET VCOM Utility to search the Media Converter which with DHCP assigned IP address.  
4.4 Operation Mode  
The ICS-10x make connected Serial equipment becomes IP-based. That also makes them be able to connect to a TCP/IP  
networking immediately. The ICS-10x allow traditional Computer/Client COM ports access to a serial equipment  
anywhere on the Ethernet LAN network.  
This Operation Mode configure page allows setup Serial interface operation mode as below:  
TCP Server  
TCP Client  
UDP Client  
Virtual COM  
Telnet Server  
Pair connection (local)  
Pair connection (Master)  
Figure 4-11 Operation Mode Configuration screen  
Select the operation mode for the application and press the “Apply” button to take affect.  
4.4.1 TCP server mode  
When the ICS-10x be configured to TCP Server mode, it allows Serial device that connected to serial port of ICS-10x to  
establish TCP communication over Intranet or Internet network between:  
Remote Host (Computer) with Serial applications using TCP/IP network socket programs  
-23-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Other ICS-10x with TCP Client mode  
It opens the TCP port of ICS-10x to wait for serial application to establish a TCP connection. After the connection is  
established, data can be transmitted in both directions.  
The parameter defines the maintenance status for listen for the TCP connection.  
Figure 4-12 TCP Server mode  
The screen in Figure 4-13 appears. When the changed operation mode, the user should be changed the Serial Port  
Configuration.  
Figure 4-13 TCP Server Configuration screen  
The page includes the following fields:  
Serial Port Operation  
Mode  
Choose different mode:  
TCP Server  
TCP Client  
UDP Client  
Virtual COM  
Telnet Server  
Pair connection (local)  
Pair connection (Master)  
The default mode is “TCP Server”.  
TCP Port Number  
The TCP port that ICS-10X uses to listen to connections and that other device  
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the  
default is set to “1024”.  
-24-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Inactive Timeout  
Example: Use Microsoft Windows Hyper Terminal, TCP/IP Winsock mode  
HyperTerminal is a program that you can use to connect to other computers, Telnet sites, online services, and host  
computers, using either your modem, a null modem cable, a Console cable or Ethernet connection.  
The users want to use the TCP Server mode to connect to a Ethernet Switch via Hyper Terminal, Winsock mode  
1.  
2.  
Setup Operation Mode and Serial Port of ICS-10x  
Hyper Terminal set up a new connection with the TCP/IP Winsock  
Setup Operation Mode and Serial Port of ICS-10x  
1.  
From the WEB interface, set the Serial operation mode of ICS-10x to “TCP Server” and set the TCP Port Number to  
23”.  
Figure 4-14 Example: TCP Server Configuration screen  
2.  
Set the Serial Port Configuration of ICS-10x as below:  
Mode:  
RS-232  
9600  
8
Baudrare:  
Character Bits:  
Parity Type :  
Stop Bit :  
none  
1
Hardware Flow Control:  
none  
-25-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-15 Example: Serial Port Configuration screen  
Hyper Terminal setup a new connection with TCP/IP Winsock  
3.  
Open HyperTerminal  
Figure 4-16 Example Hyper Terminal screen  
-26-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4.  
5.  
6.  
On the File menu, click New Connection.  
In the Name box, type a name that describes the connection.  
In the Icon box, click the appropriate icon, and then click OK.  
Figure 4-17 Example: Hyper Terminal – Create new connection  
7.  
In the Connect To dialog box, choose which port or modem you want to use in the Connect using drop-down box.  
Figure 4-18 Example: Hyper Terminal – Connect type  
8.  
9.  
In this case we are connecting via TCP/IP (Winsock), enter the host address and port number, and then click OK.  
If the Port Settings dialog box is displayed, complete the information, and click OK.  
-27-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-19 Example: Hyper Terminal configuration  
Value  
Description  
Host address  
The address or name of the connection you want to create. This can be in standard Internet  
dotted notation (for example, w.x.y.z) or can be the site's user-friendly name.  
port  
The number of the port that you want the connection to use. Port 23 is the default.  
10. Then can use the console like connect the serial cable with the switch.  
Figure 4-20 TCP/IP Winsock connection screen  
-28-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4.4.2 TCP Client mode  
When the ICS-10x be configured to TCP Client mode, it allows Serial device that connected to serial port of ICS-10x to  
establish TCP communication actively over Intranet or Internet network between:  
Remote Host (Computer) with Serial applications using TCP/IP network socket programs  
Other ICS-10x with TCP Server mode  
After the data has been transferred, the ICS-10x can disconnect automatically from the Remote Host depends on the TCP  
Inactive timeout settings. The parameter defines the maintenance status for listen for the TCP connection.  
Figure 4-21 TCP Client Mode  
The screen in Figure 4-22 appears. When the changed operation mode, the user should be changed the Serial Port  
Configuration.  
Figure 4-22 TCP Client Configuration screen  
The page includes the following fields:  
Remote Host IP  
Address  
Allow the ICS-10X to connect actively to the remote host whose IP address is set  
by this parameter.  
Remote Host Port  
Number  
The remote host port number that ICS-10X uses to listen to connections and that  
other device must use to contact ICS-10X. To avoid conflicts with well known  
TCP ports, the default is set to “1024”.  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Inactive Timeout  
-29-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.4.3 UDP Client mode  
When the ICS-10x be configured to UDP Client mode, it allows Serial device that connected to serial port of ICS-10x to  
quickly transmit data to multiple Remote Hosts over Intranet or Internet network by unicast or multicast. It also makes the  
Serial device to receive data from more than one Remote Hosts.  
The parameter defines the maintenance status for listen for the UDP connection. In UDP Client mode, you need to define  
the remote IP Address and Local listen port number.  
Figure 4-23 UDP Client Mode  
The screen in Figure 4-24 appears. When the changed operation mode, the user should be changed the Serial Port  
Configuration.  
Figure 4-24 UDP Client Configuration screen  
-30-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
The page includes the following fields:  
Local UDP Port  
Remote Address  
Remote Port  
Enter the local port number  
Enter the IP address of the remote device.  
Enter the remote port number of the remote device.  
4.4.4 Virtual COM mode  
When the ICS-10x be configured to Virtual COM mode, it allows Serial device that connected to serial port of ICS-10x to  
establish TCP communication over Intranet or Internet network between Remote Host (Computer). The Virtual COM Port  
driver has to be installed at the Remote Host. Users can send data by Virtual COM port, and Virtual COM port will transfer  
data to Ethernet by windows socket. The Virtual COM driver maps IP Address / Port of ICS-10x to a local COM port on the  
Remote Host (Computer). Once the Virtual COM connection is established, the applications work as the serial device is  
direct connected to the Remote Host’s real COM port. After the connection is established, data can be transmitted in both  
directions.  
With connect to ICS-10x Serial over Fast Ethernet Converter, the serial devices are not limited to physical connection to  
the PC/Remote Host COM port and able to be extension over longer distance. The parameter defines the maintenance  
status for the Virtual COM.  
Figure 4-25 Virtual COM Mode  
When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-14  
appears.  
Figure 4-26 Virtual COM Configuration screen  
-31-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
The page includes the following fields:  
TCP Port Number  
The TCP port that ICS-10X uses to listen to connections and that other device  
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the  
default is set to “1024”.  
Inactive Timeout  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Example: Use PLANET VCOM Utility + Microsoft Windows Hyper terminal COM  
Port mode  
Figure 4-27 Example Virtual COM Mode  
The user want to use the virtual COM like to use the serial cable connect the switch.  
1.  
2.  
3.  
Setup Operation Mode and Serial Port of ICS-10x  
Use PLANET VCOM Utility to create virtual COM Port  
Hyper Terminal set up a new connection with the virtual COM port  
Setup Operation Mode and Serial Port of ICS-10x  
1.  
From the WEB interface, set the Serial operation mode of ICS-10x to “Virtual COM” and set the TCP Port Number  
to “23”.  
-32-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-28 Example: Virtual COM Configuration screen  
2.  
Set the Serial Port Configuration of ICS-10x as below:  
Mode:  
RS-232  
9600  
8
Baudrare:  
Character Bits:  
Parity Type :  
Stop Bit :  
none  
1
Hardware Flow Control:  
none  
Figure 4-29 Example: Serial Port Configuration screen  
-33-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
VCOM Utility to create virtual COM port  
3.  
This mode will run with the software-“PLANET VCOM Utility”. Open the VCOM utility, click “Search Device” to point  
out the ICS-10x that want to be configured.  
Figure 4-30 Example: Virtual COM Configuration screen  
4.  
Choose the VCOM tab and create COM 9 like below:  
Figure 4-31 Example: Virtual COM Configuration screen  
-34-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Hyper Terminal setup a new connection with virtual COM port  
5.  
6.  
7.  
On the File menu, click New Connection.  
In the Name box, type a name that describes the connection.  
In the Icon box, click the appropriate icon, and then click OK.  
Figure 4-32 Example: HyperTerminal Configuration screen  
8.  
In the Connect to dialog box, choose which port you want to use in the Connect using drop-down box. In this case,  
choose COM9 (as created in Step-4)  
Figure 4-33 Example: HyperTerminal Configuration screen  
9.  
Set the parameter like below, click “Apply” to take effect.  
-35-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-34 Example: HyperTerminal Com port properties screen  
10. After the Virtual COM connection is established, open the VCOM utility again to check the COM9 information.  
Figure 4-35 Example: VCOM Utility, COM9 information  
11. Then can use the console like connect the serial cable with the switch.  
-36-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-36 Example: Hyper Terminal COM port screen  
4.4.5 Telnet Server mode  
TELNET (TELecommunication NETwork) is a network protocol used on the Internet or local area network (LAN)  
connections. The Telnet protocol type is the correct setting for most servers and serial devices, such as Managed Ethernet  
switches or Gateways. In most of the case, the telnet use TCP port 23 as communication port.  
The parameter defines the maintenance status for Telnet server.  
Figure 4-37 Com port screen  
When the changed operation mode, the user should be changed the Serial Port Configuration. The screen in Figure 4-38  
appears.  
-37-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Figure 4-38 Telnet Server Configuration screen  
The page includes the following fields:  
TCP Port Number  
The TCP port that ICS-10X uses to listen to connections and that other device  
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the  
default is set to “1024”.  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Inactive Timeout  
The ICS-10X’s “telnet server mode”--if the user used the MS-DOS telnet command it will  
show double character. So the user can use other Telnet software like: “putty” or “NetTerm”.  
Example 1: Telnet Command in Windows Platform  
Figure 4-39 Example Telnet Server  
-38-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Setup Operation Mode and Serial Port of ICS-10x  
1. Set the ICS-10X mode to “Telnet server mode” from web interface.  
2. Set the Serial Port Configuration of ICS-10x as below:  
Mode:  
RS-232  
9600  
8
Baudrare:  
Character Bits:  
Parity Type :  
Stop Bit :  
none  
1
Hardware Flow Control:  
none  
Execute “Telnet” command from Windows Start Menu  
3. Click the Start Menu and go to Run  
4. Type "telnet" without the quotes, and hit enter.  
Figure 4-40 Example Windows Excuse - Telnet  
5. While the Telnet window appears, type “open xxx,xxx,xxx,xxx”, xxx is the IP address of the ICS-10x Telnet Server.  
In this case we type “open 192.168.0.100” and press enter.  
Figure 4-41 Example Windows Excuse - Telnet  
6. Then can use the telnet connection to configure the switch just like console direct connect to the COM port of the  
switch.  
-39-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-42 Example Windows Excuse - Telnet  
7. To quit the Telnet session, press “CTRL+]” and then type “quit”  
Figure 4-43 Example Windows Excuse - Telnet  
Example 2: Putty software in Windows Platform  
PuTTY is a free implementation of Telnet and SSH for Win32 and Unix platforms, along with an xterm terminal emulator.  
In this case we use Putty to telnet to the ICS-10x-Telnet Server mode for remote console login.  
1. Set the ICS-10X mode to “Telnet server mode” from web interface.  
2. Run the Telnet software like “Putty” and set the parameter like below:  
-40-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-44 Putty Configuration screen  
8. Then can telnet IP address like to telnet switch’s IP.  
Figure 4-45 Putty telnet screen  
-41-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4.4.6 Pair Connection– Local mode  
The parameter defines the maintenance status for listen for the pair connection. To make a long distance communication  
between two serial equipment, configure two ICS-10x with Pair Connection mode and setup one as a Master (Local side)  
and the other as a Slave (Remote side).  
Pair Connection – Local (Master) – the ICS-10x is locate close to the Host Computer or control device and  
connect to it via serial interface.  
Pair Connection – Remote (Slave) – the ICS-10x is locate close to the remote serial equipment and connect to  
it via serial interface..  
Figure 4-46 Pair Connection mode  
In effect, this converter will be acting as a TCP server. The screen in Figure 4-46 appears. When the changed operation  
mode, the user should be changed the Serial Port Configuration.  
Figure 4-47 Pair Connection – Local (Master) Configuration screen  
TCP Port Number  
The TCP port that ICS-10X uses to listen to connections and that other device  
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the  
default is set to “1024”.  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Inactive Timeout  
-42-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
4.4.7 Pair Connection – Remote mode  
The parameter defines the maintenance status for listen for the pair connection. In effect, this converter will be acting as a  
TCP client. The screen in Figure 4-48 appears.  
When the changed operation mode, the user should be changed the Serial Port Configuration.  
Figure 4-48 Pair Connection – Remote (Slave) Configuration screen  
TCP Port Number  
The TCP port that ICS-10X uses to listen to connections and that other device  
must use to contact ICS-10X. To avoid conflicts with well known TCP ports, the  
default is set to “1024”.  
Use the parameter to set an inactive timeout. The unit drops the connection if  
there is no activity on the serial line before the set time expires. To disable the  
inactive timeout enter “0”.  
Inactive Timeout  
Important!  
While using Pair Connection mode for two RS-232 services distance extend, the DB9/RS-232 cables  
are very importance in this application. There are much kind of RS-232 cables, such as straight cable  
(standard) and Null-Modem cable. Please make sure the DB9/RS-232 cables match the below  
constriction:  
Serial Device to ICS-10x/Remote (Slave) – Use the original RS-232 serial cable attached in the  
serial device package.  
Host / Client to ICS-10x/Local (Master) – It has to use the Null-Modem cable!  
Users can use the Null-Modem cable directly connect to the ICS-10x (Master), or use the Null-Modem  
DB9 connector, as the picture shows:  
Once the Pair Connection mode of two ICS-10x be correctly configured but still fail link, check the  
RS-232 cables!  
-43-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Example: Two ICS-10x with Pair Connection mode  
One be configured as Pair Connection – Local (Master)  
The other one be configured as Pair Connection – Remote (Slave)  
Via the RS-485 interface, the external scanners, speed dome cameras and PTZ receivers can be controlled by the  
keyboard which provides upward, downward, leftward, rightward, clockwise and counterclockwise with the joystick. In this  
case, we use two ICS-10x to extend the distance between an IP surveillance PT Camera and a Control keyboard. Both of  
the two equipments are implemented with RS-485 interface.  
The two of the ICS-10x master and slave with below settings:  
ICS-10x Master  
Connect to  
Control Keyboard  
IP Address / Subnet Mask  
192.168.0.100 / 255.255.255.0  
Mode: Pair Connection – Local  
TCP Port Number : 1024  
Operation Mode  
Serial Mode: RS-485  
Baudrare: 9600  
Character Bits: 8  
Parity Type : none  
Stop Bit : 1  
Serial Port Configuration  
Hardware Flow Control: none  
ICS-10x Slave  
Connect to  
Speed Dome Camera, PTZ or Scanner  
192.168.0.101 / 255.255.255.0  
IP Address / Subnet Mask  
Mode: Pair Connection – Remote  
Remote Host IP Address : 192.168.0.100  
Remote Host Port Number : 1024  
Operation Mode  
Serial Mode: RS-485  
Baudrare: 9600  
Character Bits: 8  
Parity Type : none  
Stop Bit : 1  
Serial Port Configuration  
Hardware Flow Control: none  
Topology:  
Figure 4-49 Two ICS-10x configured with Pair-Connection  
-44-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
1. Connect the converter with the IP camera for RS-485 interface like PLANET product: “ICA-651”.  
2. Connect the converter with the control keyboard for RS-485 interface like PLANET product: “CAM-KB300”.  
ICS-10x – Master: be configured as Pair-Connection-Local  
3. From Web interface, login the ICS-10x with IP address = 192.168.0.100, set up the operation mode of this unit to be  
Pair Connection-Local (master)”  
Figure 4-50 Pair Connection – Local, operation mode configuration  
4. Set the Serial Port mode of ICS-10x-Master to RS-485.  
Figure 4-51 Pair Connection – Local, serial port configuration  
ICS-10x – Slave: be configured to Pair-Connection-Remote  
5. From Web interface, login the ICS-10x with IP address = 192.168.0.101, set up the operation mode of this unit to be  
Pair Connection-Local (master)”  
-45-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 4-52 Pair Connection –Remote, operation mode configuration  
6. Set the Serial Port mode of ICS-10x-Slave to RS-485.  
Figure 4-51 Pair Connection – Local, serial port configuration  
7. Then the control keyboard cans remote control the IP camera.  
-46-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
4.5 Serial Port Configuration  
The page shows the converter’s serial Port configuration. The screen in Figure 4-52 appears.  
Figure 4-52 Converter Status page screen  
The page includes the following fields:  
Mode  
From the drop-down menu, select the serial port mode:  
RS232  
RS-422  
RS-485  
Baudrate  
The unit and attached serial device, such as a modem, must agree on a speed or  
baud rate to use for the serial connection, Valid baud rates.  
It’s in the range of 110bps to 921600bps.  
Character Bits  
Indicates the number of the bits in a transmitted data package. The allowed value  
is 5,6,7,8  
The default is “8”.  
Parity type  
Checks for the parity type. The default value is “none”.  
The stop bit follows the data and parity bits in serial communication. It indicates  
the end of transmission. The default is “1”.  
Stop Bit  
Flow control manages data flow between devices in a network to ensure it is  
processed efficiently. Too much data arriving before a device is prepared to  
manage it causes lost or retransmitted data.  
Hardware Flow Control  
XON/XOFF, RTS/CTS, DTR/DSR  
The default value is “none”.  
Delimiter  
Character The Character 1 and Character 2 allow the use to enter two ASCII  
character (in hex format) that delimit the beginning and end of a message. When  
a message with both there delimiters is received at the serial port, the data  
-47-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
contained in the serial buffer is paced in an Ethernet packet and sent out the  
Ethernet port.  
Silent Time: For the defined period of time passed, the serial port stops data  
transmission and close the connection to remote host.  
Drop Character: If the incoming data contain character 1 or character 2, the  
packet will be dropped  
The default value is “Disable”  
Logout  
Press this function; the web interface will go back to login screen. The screens in Figure 4-53 and Figure 4-54 appear.  
Figure 4-53 Logout dialogues screen  
Figure 4-54 Login screen  
-48-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
5. SOFTWARE VCOM UTILITY  
The ICS-10X Web Smart Media Converter provides software for Converter smart function configuration when the  
Converter operation mode on “Virtual COM”. - They can be configured through the Console. Two function groups are  
provide to easy used, can search device and create virtual COM to view as the console port.  
This program can search ICS-10x Series devices, it will show information of the device. And user can use VCOM function  
creates virtual com port for user using. Users can send data by virtual com port, and virtual com port will transfer data to  
Ethernet by windows socket. While VCOM got data from Ethernet, it will transfer data to virtual com port by virtual com  
component.  
The VCOM is an integrated software suite that bundles Device Server Administrator and IP Serial Library, and provides  
something you need to monitor your ICS-10X from a remote location.  
5.1 Installing the VCOM Utility  
1.  
Once the Setup program starts running, click Next when the Welcome window opens to proceed with the  
installation.  
Figure 5-1 VCOM installation screen  
2.  
Click Install to install the program.  
Figure 5-2 VCOM installation screen  
-49-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
3.  
4.  
The Installing window reports the progress of the installation.  
Click Finish to complete  
Figure 5-3 VCOM installation screen  
5.  
To run the PLANET VCOM utility on the computer, click “Start” \ “Programs” \ “PLANET VOM Utility” \ “VCOM”  
Figure 5-4 VCOM program path  
The VCOM contains two pages: Search Device and VCOM. The Search Device has device information and the VCOM  
show the virtual COM information.  
-50-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
5.2 Search the Device  
Click the Search Device button to find the ICS-10X. It will show the ICS-10X device name, project name, MAC address, IP  
address, Sub Mask, Gateway and the connect port number.  
1.  
2.  
Click the shortcut of VCOM on the desktop to run the VCOM program.  
Click "Search Device" button in Search Device tab. If any ICS-10x series device on the LAN, it will show the device  
name in the tree report. While user click the device name, it will show device information in the list report.  
Figure 5-5 VCOM Device Search  
5.3 Virtual COM  
This function should be set the ICS-10X’s operation mode to “Virtual COM” on the Web.  
Choose to create port like below:  
1.  
2.  
3.  
4.  
If the device support Telnet, while user click device name, it will show VCOM tab.  
While user click VCOM tab, it will fill IP Address and Port number automatically.  
Select COM Port Name  
Click "Create Port" button to create new virtual com port and establish telenet connection  
-51-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
Figure 5-6 VCOM Configuration  
Then set the HyperTerminal parameter  
5.  
Figure 5-7 Hyper Terminal Configuration  
6.  
then the VCOM will show connect information like below:  
-52-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
Figure 5-8 VCOM Configuration  
7.  
Once the Virtual COM Port- COM9 connection is established, from the Windows Device Manager, a COM Port is  
added to the device list.  
Figure 5-9 Windows Device Server - Virtual COM Port  
When the Virtual COM create com port, the Device Manager will add “Virtual Serial Port”.  
And delete the Port on the VCOM, the device will disappear.  
-53-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
User’s Manual of ICS-10x  
APPENDIX A  
A.1 PLANET Smart Discovery Utility  
For easily list the ICS-10X in your Ethernet environment, the Planet Smart Discovery Utility from user’s manual CD-ROM  
is an ideal solution.  
The following install instructions guiding you for run the Planet Smart Discovery Utility.  
1. Deposit the Planet Smart Discovery Utility in administrator PC.  
2. Run this utility and the following screen appears.  
Figure A-1 Planet Smart Discovery Utility Screen  
If there are two LAN cards or above in the same administrator PC, choose different LAN card by  
use the “Select Adapter” tool.  
3. Press “Refresh” button for list current connected devices in the discovery list, the screen is shown as follow.  
Figure A-2 Planet Smart Discovery Utility Screen  
-54-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
1. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version,  
Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices.  
2. After setup completed, press “Update Device”, “Update Multi” or “Update All” button to take affect. The meaning of  
the 3 buttons above are shown as below:  
Update Device: use current setting on one single device.  
Update Multi: use current setting on choose multi-devices.  
Update All: use current setting on whole devices in the list.  
The same functions mentioned above also can be finding in “Option” tools bar.  
3. To click the “Control Packet Force Broadcast” function, it can allow assign new setting value to the Web Smart  
Switch under different IP subnet address.  
6. Press “Connect to Device” button then the Web login screen appears.  
7. Press “Exit” button to shutdown the planet Smart Discovery Utility.  
A.2 Device‘s RJ-232/RS-422/RS-485 Pin Assignments  
¾
DB9 Pin Define for RS-232 / RS-422 / RS-485  
RS-422/485  
4-wire  
RS-485  
2-wire  
DB9-PIN  
RS-232  
1
2
3
4
5
6
7
8
9
DCD  
RXD  
TXD  
DTR  
GND  
DSR  
RTS  
CTS  
RI  
RX-  
Data B(-)  
Data A(+)  
TX-  
RX+  
TX+  
A.3 Device‘s RJ-45 Pin Assignments  
10/100Mbps, 10/100Base-TX  
Contact  
MDI  
MDI-X  
1
1 (TX +)  
2 (TX -)  
3 (RX +)  
6 (RX -)  
Not used  
3
2
6
3
6
1
2
4, 5, 7, 8  
Not used  
Implicit implementation of the crossover function within a twisted-pair cable, or at a wiring panel, while not expressly  
forbidden, is beyond the scope of this standard.  
-55-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
A.4 RJ-45 cable pin assignment  
21  
3
6
6
321  
6
3
2
1
There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation  
and color of straight cable and crossover cable connection:  
Straight Cable  
SIDE 1  
SIDE2  
1 = White / Orange  
2 = Orange  
1 = White / Orange  
2 = Orange  
1
2
3
4
5
6
7
8
SIDE 1  
SIDE 2  
3 = White / Green  
4 = Blue  
3 = White / Green  
4 = Blue  
5 = White / Blue  
6 = Green  
5 = White / Blue  
6 = Green  
1
2
3
4
5
6
7
8
7 = White / Brown  
8 = Brown  
7 = White / Brown  
8 = Brown  
Straight Cable  
SIDE 1  
SIDE2  
1 = White / Orange  
2 = Orange  
1 = White / Orange  
2 = Green  
1
2
3
4
5
6
7
8
SIDE 1  
SIDE 2  
3 = White / Green  
4 = Blue  
3 = White / Orange  
4 = Blue  
5 = White / Blue  
6 = Green  
5 = White / Blue  
6 = Orange  
1
2
3
4
5
6
7
8
7 = White / Brown  
8 = Brown  
7 = White / Brown  
8 = Brown  
Figure A-1: Straight-Through and Crossover Cable  
Please make sure your connected cables are with same pin assignment and color as above picture before deploying the  
cables into your network.  
-56-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
User’s Manual of ICS-10x  
A.5 Fiber Optical Cable Connection Parameter  
The wiring details are as below:  
Fiber Optical patch Cables: (For ICS-102 / ICS-102S)  
Standard  
100Base-FX  
(1300nm)  
Fiber Type  
Cable Specification  
Multi-mode  
50/125μm or 62.5/125μm  
100Base-FX  
(1310nm)  
Multi-mode  
50/125μm or 62.5/125μm  
Single-mode  
9/125μm  
A.6 Power Information  
The power jack of ICS-10X is with 2.5mm in the central post and required +5VDC power input. It will conform to the  
bundled AC-DC adapter and Planet’s Media Chassis. Should you have the problem to make the power connection, please  
contact your local sales representative.  
Please keep the AC-DC adapter as spare parts when your ICS-10X is installed to a Media Chassis.  
2.5mm  
DC Receptacle 2.5mm  
+5V for each slot  
DC receptacle is 2.5mm wide that conforms to and matches the Media Converter 2.5mm DC  
jack's central post. Do not install any improper unit, model of the Media Converter  
2080-AA3600-000  
-57-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
EC Declaration of Conformity  
For the following equipment:  
*Type of Product: RS-232 / RS-422 / RS-485 over 10/100Base-TX Media Converter  
(1 DB9, 1 RJ-45)  
*Model Number : ICS-100  
* Produced by:  
Manufacturer‘s Name  
:
Planet Technology Corp.  
Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien  
Taipei, Taiwan , R. O.C.  
is herewith confirmed to comply with the requirements set out in the Council Directive on the  
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility  
Directive on (89/336/EEC).  
For the evaluation regarding the EMC, the following standards were applied:  
Emission  
EN 55022  
(1994 + A1:1995 + A2:1997  
Class A)  
Harmonic  
Flicker  
Immunity  
ESD  
RS  
EFT/ Burst  
Surge  
EN 61000-3-2  
EN 61000-3-3  
EN 55024  
IEC 61000-4-2  
IEC 61000-4-3  
IEC 61000-4-4  
IEC 61000-4-5  
IEC 61000-4-6  
IEC 61000-4-8  
IEC 61000-4-11  
(2000)  
(1995 + A1:2001)  
(1998)  
(1995 + A1:1998 + A2:2000)  
(1995 + A1:1998 + A2:2000)  
(1995 + A1:2000)  
(1995 + A1:2000)  
(1996 + A1:2000)  
(1993 + A1:2000)  
(1994 + A1:2000)  
CS  
Magnetic Field  
Voltage Disp  
Responsible for marking this declaration if the:  
Manufacturer  
Authorized representative established within the EU  
Authorized representative established within the EU (if applicable):  
Company Name:  
Planet Technology Corp.  
Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C  
Person responsible for making this declaration  
Name, Surname  
Position / Title :  
Kent Kang  
Product Manager  
Taiwan  
18, March., 2008  
Place  
Date  
Legal Signature  
PLANET TECHNOLOGY CORPORATION  
11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528  
Download from Www.Somanuals.com. All Manuals Search And Download.  
EC Declaration of Conformity  
For the following equipment:  
*Type of Product: RS-232 / RS-422 / RS-485 over 100Base-FX Media Converter  
(1 DB9, 1 Fiber SC connector)  
*Model Number : ICS-102 / ICS-102S15 / ICS-105A  
* Produced by:  
Manufacturer‘s Name  
:
Planet Technology Corp.  
Manufacturer‘s Address : 11F, No. 96, Min Chuan Road, Hsin Tien  
Taipei, Taiwan , R. O.C.  
is herewith confirmed to comply with the requirements set out in the Council Directive on the  
Approximation of the Laws of the Member States relating to Electromagnetic Compatibility  
Directive on (89/336/EEC).  
For the evaluation regarding the EMC, the following standards were applied:  
Emission  
EN 55022  
(1994 + A1:1995 + A2:1997  
Class A)  
Harmonic  
Flicker  
Immunity  
ESD  
RS  
EFT/ Burst  
Surge  
EN 61000-3-2  
EN 61000-3-3  
EN 55024  
IEC 61000-4-2  
IEC 61000-4-3  
IEC 61000-4-4  
IEC 61000-4-5  
IEC 61000-4-6  
IEC 61000-4-8  
IEC 61000-4-11  
(2000)  
(1995 + A1:2001)  
(1998)  
(1995 + A1:1998 + A2:2000)  
(1995 + A1:1998 + A2:2000)  
(1995 + A1:2000)  
(1995 + A1:2000)  
(1996 + A1:2000)  
(1993 + A1:2000)  
(1994 + A1:2000)  
CS  
Magnetic Field  
Voltage Disp  
Responsible for marking this declaration if the:  
Manufacturer  
Authorized representative established within the EU  
Authorized representative established within the EU (if applicable):  
Company Name:  
Planet Technology Corp.  
Company Address: 11F, No.96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C  
Person responsible for making this declaration  
Name, Surname  
Position / Title :  
Kent Kang  
Product Manager  
Taiwan  
24, March., 2008  
Place  
Date  
Legal Signature  
PLANET TECHNOLOGY CORPORATION  
11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. Tel:886-2-2219-9518 Fax:886-2-2219-9528  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer MPA 700 User Manual
Philips Digital Photo Frame GPIM 08 User Manual
Philips Stereo System DCM292 37 User Manual
Pioneer Stereo Receiver XS 950 User Manual
Planet Technology Network Card NAS 7201 User Manual
Planet Technology Network Card WL U350 User Manual
Porter Cable Cordless Saw 90550119 User Manual
Powermate Portable Generator PMA535202 User Manual
ProForm Home Gym PFBE66080 User Manual
PYLE Audio Computer Monitor PLDVDBG5 User Manual