Nikon Microscope Magnifier LV100D User Manual

Industrial Microscopes LV150/150A/100D  
Industrial Microscopes  
Specifications and equipment are subject to change without any notice or obligation  
on the part of the manufacturer. April 2005. ©2000-05 NIKON CORPORATION  
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS  
WARNING  
CAREFULLY BEFORE USING YOUR EQUIPMENT.  
NIKON CORPORATION  
Fuji Bldg., 2-3, Marunouchi 3-chome, Chiyoda-ku,  
Tokyo 100-8331, Japan  
NIKON INSTECH CO., LTD.  
Parale Mitsui Bldg., 8, Higashida-cho, Kawasaki-ku,  
Kawasaki, Kanagawa 210-0005, Japan  
phone: +81-44-223-2175 fax: +81-44-223-2182  
NIKON INSTRUMENTS EUROPE B.V.  
P.O. Box 222, 1170 AE Badhoevedorp, The Netherlands  
phone: +31-20-44-96-222 fax: +31-20-44-96-298  
NIKON INSTRUMENTS INC.  
1300 Walt Whitman Road, Melville, N.Y. 11747-3064, U.S.A.  
phone: +1-631-547-8500; +1-800-52-NIKON (within the U.S.A.only) fax: +1-631-547-0306  
NIKON FRANCE S.A.S.  
NIKON CANADA INC.  
FRANCE phone: +33-1-45-16-45-16 fax: +33-1-45-16-00-33  
NIKON GMBH  
GERMANY phone: +49-211-9414-0 fax: +49-211-9414-322  
NIKON INSTRUMENTS S.p.A.  
ITALY phone: + 39-55-3009601 fax: + 39-55-300993  
NIKON AG  
SWITZERLAND phone: +41-43-277-2860 fax: +41-43-277-2861  
NIKON UK LTD.  
CANADA phone: +1-905-625-9910 fax: +1-905-625-0103  
NIKON INSTRUMENTS (SHANGHAI) CO., LTD.  
CHINA phone: +86-21-5836-0050 fax: +86-21-5836-0030  
(Beijing office)  
CHINA phone: +86-10-5869-2255 fax: +86-10-5869-2277  
NIKON SINGAPORE PTE LTD  
SINGAPORE phone: +65-6559-3618 fax: +65-6559-3668  
NIKON MALAYSIA SDN. BHD.  
MALAYSIA phone: +60-3-78763887 fax: +60-3-78763387  
UNITED KINGDOM phone: +44-20-8541-4440 fax: +44-20-8541-  
En  
Printed in Japan (0504-05)T  
Code No. 2CE-KWFH-7  
This brochure is printed on recycled paper made from 40% used material.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Versatility  
The modular design of the Eclipse LV series  
allows an unprecedented level of versatility. The  
Eclipse LV series offers flexibility that enables it  
to cover a wide variety of products and  
applications, extending from development and  
quality control to inspection in the manufacturing  
process. Users will recognize the superb  
performance of the Eclipse LV series when  
inspecting semiconductors, FPD, packages,  
electronics substrates, materials (material  
science), medical devices, cast/metallic/ceramic  
parts, precision molds, MEMS, telecommuni-  
cations devices, and a wide variety of other  
samples.  
Accepts taller samples  
Extensive range of industrial stages and  
accessories  
Users can select suitable models based on sample and stage  
stroke. All stages are highly durable with triple-plate design.  
Dia base unit for diascopic illumination  
The maximum sample height can be increased to 82mm from  
47mm by inserting the LV-CR Column Riser 35 between the  
main body and arm of the microscope. This feature is useful  
for viewing the surfaces of precision molds, optical materials  
and other thick samples.  
In the Eclipse LV series, the LV-DIA Dia Base is available for  
diascopic illumination OEM use. Users can now take full  
advantage of the modular design. A UN2 transformer is used  
for the power supply.  
Compact industrial stage: LV-S32 3x2 Stage  
The newly designed LV-S32 3x2 is a compact stage for  
industrial microscopes. Its triple-plate design ensures  
durability, stability and ease of  
Roll-out section  
Roll-in section  
Tape-suction  
section  
Tape-transport  
section  
use, even when heavy samples  
such as metallic materials are  
observed. The standard glass  
plate makes this stage suitable  
Stage section  
82mm  
47mm  
for episcopic and diascopic  
illumination.  
LV-S32 3x2 Stage  
Stroke: 75 x 50 mm  
Without column riser  
With column riser  
An example of LV-DIA Dia Base built into a taped sample inspection system  
LV-S64 6x4 Stage  
Stroke: 150 x 100 mm  
Non-Nikon stages (LV150 or LV150A  
only)  
Modular design  
Use of non-Nikon stages, such as the Suruga Seiki B23-60CR,  
in combination with the LV-SUB Substage 2 allows the  
microscope to handle taller samples of up to 116.5 mm,  
thereby enabling the observation of fiber ends and other  
tools.  
LV-S6 6x6 Stage  
Stroke: 150 x 150 mm  
LV-DIA Bia Base  
LV-SUB Stage  
LV-SUB Substage 2  
(exclusive for LV150/LV150A)  
(exclusive for LV150/LV150A)  
Combination of LV-150 with LV-SUB Substage 2  
and Suruga Seiki B23-60CR stage  
L-S6WH Wafer Holder 6  
(for LV-S6 6x6 Stage)  
L-S6PL ESD Plate  
(for LV-S6 6x6 Stage)  
LV150 standard combination  
LV-S32PL ESD Plate  
(for LV-S32 3x2 Stage)  
LV-S32SGH Slideglass Holder  
(for LV-S32 3x2 Stage)  
Appropriate holder and substage are selected based on  
sample and stage combination.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Versatility  
Extend your vision  
Optical Performance  
A wide variety of observation methods is available with the Eclipse LV series. Observations with first-order  
compensator, UV polarizing, and epi-fluorescence observations with UV excitation, in addition to brightfield,  
darkfield, DIC, simple polarizing, epi-fluorescence (excitation using visible light) and double-beam  
interferometry are all possible. Two new light sources also have been developed: high-intensity, low power-  
consumption 12V-50W halogen light source and adjustable high-intensity mercury-fiber light source.  
Transmission wavelength coverage  
extended to UV  
CFI LU Plan Fluor series  
The new CFI LU Plan Fluor series covers transmission  
wavelength ranges up to UV. These objective lenses are suitable  
for various research, analysis and examination needs, while  
maintaining Nikon’s commitment to high NA and long working  
distance. Only one kind of objective lens is needed for  
brightfield, darkfield, simple polarizing, observation with first-  
order compensator, DIC and UV epi-fluorescence observations.  
These objective lenses, which offer high resolution and easy-to-  
use performance, can be combined not only with microscopes  
but also with other equipment for even greater versatility.  
Universal epi-illuminator: LV-UEPI  
High-intensity 12V-50W halogen  
light source:  
The LV-UEPI universal epi-illuminator enables  
brightfield, darkfield, simple polarizing and DIC  
observations. Field and aperture diaphragms are  
automatically opened when the observation is switched  
from brightfield to darkfield, and return to their original  
position when switched back to brightfield.  
CFI60 LU Plan Fluor EPI series  
LV-LH50PC Precentered  
Lamphouse  
Although the LV-LH50PC Precentered Lamphouse  
is 12V-50W, the brightness is equivalent to or  
higher than that of 12-100W types. The low power-  
consumption halogen light source contributes to  
the compact design of the microscope while also  
being friendly to the environment. Focus drift due  
to heat from the illuminator is substantially  
reduced.  
Objective lenses with correction ring  
CFI L Plan EPI CR series  
CFI60 LU Plan Fluor BD series  
The CFI60 series now includes the CFI L Plan EPI CR series to  
cope with the thinner coverglass used in liquid crystal displays,  
and highly integrated, and dense devices. Coverglass correction  
can be continuously made from 0 mm up to 1.2 mm (0-0.7 mm  
and 0.6-1.3 mm for 100x) with the correction ring. The 100x  
objective lens offers 0.85 high NA, while enabling high-contrast  
imaging of cells and patterns without being affected by the  
coverglass.  
Brightfield  
Darkfield  
Simple polarizing  
DIC  
CFI60 L Plan EPI CR series of objective lenses  
with correction ring  
Environmentally friendly  
The eco glass used in the CFI LU Plan Fluor and L Plan EPI CR  
series does not contain harmful substances such as lead and  
arsenic.  
Auto optimal illumination  
selection  
Universal epi-illuminator 2: LV-UEPI2  
Field  
diaphragm  
Aperture  
diaphragm  
Shutter  
UV-cut  
filter  
The LV-UEPI2 universal episcopic illuminator is  
equipped with advanced optics suited to a wide variety of  
observation methods—brightfield, darkfield, DIC and epi-  
fluorescence—and automatically sets optimal  
illumination in accordance with the field and aperture  
diaphragm, shutter, and filters, including diffuser and  
ND. This design enables the operator to concentrate on  
the observation.  
BF  
Any diameter  
Open  
Any diameter  
Open  
Open  
Open  
Open  
Open  
Insert  
Insert  
Without correction (50x)  
With correction at 0.7 mm (50x)  
DF  
FL1  
FL2  
Any diameter  
Any diameter  
Any diameter  
Any diameter  
CFI60 Series Objectives  
Model  
Magnification  
2.5X  
5X  
NA  
0.075  
0.15  
0.30  
0.45  
0.80  
0.90  
0.40  
0.55  
0.80  
0.35  
0.45  
0.70  
0.95  
0.95  
1.25  
Working Distance (mm)  
Model  
Magnification  
5X  
NA  
Working Distance (mm)  
CFI L Plan EPI  
CFI LU Plan Fluor EPI  
New  
8.8  
23.5  
17.3  
4.5  
CFI LU Plan Fluor BD  
0.15  
0.30  
0.45  
0.80  
0.90  
0.40  
0.55  
0.80  
0.90  
0.90  
18.0  
15.0  
4.5  
10X  
New  
10X  
20X  
20X  
50X  
1.0  
50X  
1.0  
100X  
20X  
1.0  
100X  
20X  
1.0  
CFI LU Plan BD ELWD  
CFI LU Plan Apo BD  
13.0  
9.8  
CFI LU Plan EPI ELWD  
CFI L Plan EPI SLWD  
13.0  
10.1  
3.5  
50X  
50X  
100X  
100X  
150X  
3.5  
100X  
20X  
0.51  
0.4  
24.0  
17.0  
6.5  
50X  
100X  
100X  
150X  
150X  
CFI LU Plan Apo EPI  
CFI L Plan Apo EPI WI  
0.4  
0.3  
Brightfield  
Darkfield  
Simple polarizing  
0.25  
Observation with first-order compensator  
UV polarizing epi-fluorescence  
DIC  
Model  
Magnification  
20x  
NA (mm)  
0.45  
Working Distance (mm) Glass Thickness Correction Range  
CFI L Plan EPI CR  
CFI L Plan EPI CR  
CFI L Plan EPI CRA  
CFI L Plan EPI CRB  
10.9-10.0  
3.9-3.0  
0-1.2mm  
0-1.2mm  
0-0.7mm  
0.6-1.3mm  
New  
New  
New  
New  
Epi-fluorescence (UV excitation possible)  
50x  
0.7  
100x  
0.85  
1.2-0.85  
1.3-0.95  
100x  
0.85  
7
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Observation Methods  
Improved performance  
Simple polarizing  
Brightfield  
Usability has been vastly improved as has durability and rigidity.  
In addition to simple  
polarizing, a lambda plate  
can be inserted into the  
optical path to achieve  
observations with a first-  
order compensator. This is  
useful for liquid crystal  
inspections (when used in  
combination with the LV-  
UEPI 2).  
The antiflare design applied  
to the objective lenses and  
light source ensures bright,  
high-contrast images.  
Tilting trinocular eyepiece tube  
Thorough ESD protection  
Darkfield  
Nikon’s unique “Fly-eye  
Lens” used in the darkfield  
illuminator yields a  
LV-TT2 Tilting Trinocular Eyepiece  
Tube  
The newly developed LV-TT2 tilting trinocular  
eyepiece tube (erect image) offers comfort to all  
users, regardless of their stature or viewing  
position. The optical path changeover of  
100:0/20:80 allows the simultaneous use of a  
monitor.  
threefold increase in  
brightness over previous  
models. This allows high-  
sensitivity detection of  
defects and height gaps in  
samples.  
YM-PO  
L-AN  
LV-PO  
LV-FLAN  
LV-P  
Polarizer  
Analyzer  
Polarizer  
FL Analyzer  
Plate  
Nomarski DIC  
Epi-fluorescence  
UV, V, BV, B or G excitation  
fluorescence filter blocks can  
be selected. This method is  
perfect for the observation of  
OEL, ion migration and other  
substrate uses.  
All parts of the microscope that might be touched,  
including the body, tube and stage, have been  
insulated. This improves anticontamination and  
prevents samples from being harmed by static  
electricity, thereby improving yields.  
Highly durable motorized nosepiece  
L-DIC DIC Prism (standard)  
L-DIHC DIC Prism (high contrast)  
Brightfield  
Epi-fluorescence B-2A  
Electrostatic decay time: 1000-10V, within 0.2 sec.  
Standard or high contrast DIC  
sliders can be selected to suit  
the sample. This method is  
useful for the surface  
Highly rigid, vibration-free body  
The use of structural analysis during the design process  
has improved rigidity and antivibration parameters to  
yield clear images even at high magnification.  
observations of various  
devices and precision molds.  
YM-PO L-AN  
Polarizer Analyzer DIC Prism High-contrast  
DIC Prism  
L-DIC  
L-DICH[??]  
LV-UV  
Polarizer  
LV-FLAN FL  
Analyzer  
LV-NU5A Nosepiece  
Fluorescence filter blocks  
The LV-NU5A motorized universal quintuple  
nosepiece is 10 times more durable than its  
predecessor and can be used with the LV150A. In  
combination with the LV-NCNT motorized  
nosepiece controller, it can also be used in other  
devices.  
Double-beam interferometry equipment  
(measures minute height gaps)  
Diascopic illumination  
Michelson (TI) and Mirau (DI)  
types of episcopic double-  
beam interferometry can be  
carried out. A filar micrometer  
eyepiece can be used to  
Diascopic illumination is  
used to observe optical  
parts, FPD and other samples  
that transmit light.  
Manual nosepiece  
A variety of manual nosepieces are available to suit  
all needs.  
examine or measure samples  
while avoiding direct contact.  
C-N6 Nosepiece  
(Brightfield)  
L-NBD5 Nosepiece  
(Bright/darkfield)  
L-NU5 Nosepiece  
(Universal)  
Condenser  
Episcopic Two-beam Interferometry Equipment TI/DI  
8
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Applications  
(Episcopic illumination type)  
Semiconductor (IC wafer)  
Semiconductor (IC wafer)  
MEMS (optical switch)  
LV-TI3 Trinocular Tube  
LV-LH50PC Precentered Lamphouse  
A trinocular tube with an  
optical path changeover  
of 100:0/0:100.  
A low power-consumption 12V-50W  
halogen light source equivalent to or  
higher than the 12V-100W type.  
CFI-series eyepiece  
Brightfield  
Darkfield  
Brightfield  
LV-UEPI  
An illuminator that can be  
used for brightfield,  
darkfield, simple  
polarizing and DIC  
observations.  
Micro bump  
Compact disc (CD)  
Image sensor (CCD)  
LV150/LV150A  
The LV150 and LV150A  
microscopes are used for  
episcopic illumination.  
LV-NU5A Nosepiece  
A universal motorized  
nosepiece that is 10 times  
more durable than its  
predecessors.  
CFI LU Plan Fluor series  
These objective lenses feature a  
high NA, long working distances  
and an extended transmission  
wavelength range.  
Brightfield  
Simple polarizing  
Brightfield  
LV-S6 6x6 Stage  
An episcopic illumination  
stage capable of inspecting  
150mm wafers. (With 6”  
wafer holder)  
PCB (ion migration)  
PCB (ion migration)  
Precision mold  
L150A controls  
Brightfield  
Epi-fluorescence  
DIC  
Motorized nosepiece controls  
10  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Applications  
(Episcopic/diascopic illumination type)  
LCD (color filter)  
LCD (conductive particle)  
Test reticle  
LV-TI3 Trinocular Tube  
LV-LH50PC 12V-50W Lamphouse  
A trinocular tube with an  
optical path changeover  
of 100:0/0:100.  
A low power-consumption 12V-50W  
halogen light source equivalent to or  
higher than the 12V-100W type.  
CFI-series eyepiece  
Diascopic brightfield  
DIC  
Diascopic brightfield  
Carbon paper  
Nodular graphite cast iron  
リシャ輝石??  
LV-UEPI2  
LV100D  
The LV-UEPI2 illuminator  
enables brightfield,  
darkfield, DIC, simple  
polarizing, and UV  
excitation epi-fluorescence  
observations.  
The LV100D microscope is  
capable of episcopic and  
diascopic illumination.  
Nosepiece  
CFI LU Plan Fluor Series  
Selectable from C-N6  
(brightfield), L-NBD5  
(bright/darkfield) and L-  
NU5 (universal) nosepieces.  
These objective lenses feature  
high NA, long working distances  
and an extended transmission  
wavelength range.  
DIC  
Brightfield  
DIC  
LV-S32 3x2 Stage  
This small, industrial-use  
stage has a triple-plate  
design and can be used for  
episcopic and diascopic  
illumination.  
Tourmaline  
Tourmaline  
Tourmaline  
Brightfield  
DIC  
Double-beam interferometry  
12  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Eyepiece tubes  
Illuminators  
Double Port  
Polarizing/DIC accessories  
Simple Polarizing  
Observation with first-order compensator  
LV-TI3 Trinocular  
LV-TT2 Tilting Trinocular Eyepiece Tube  
Eyepiece Tube ESD  
Y-IDP Double Port  
LV-UEPI  
(Beamsplit 45:55/0:100)  
Y-IDP Double Port 0/100  
(Beamsplit 100:0/0:100)  
Eyepieces  
Model  
YM-PO  
Polarizer  
L-AN  
Analyzer  
LV-PO  
Polarizer Analyzer  
LV-FLAN FL  
LV-P  
Plate  
F.O.V.  
22  
Remarks  
CFI 10x  
CFI 10xM  
UV polarizing epi-fluorescence  
DIC  
22  
Photomask included  
CFI 10×CMfor C-TE binocular ergo tube 22  
Crosshairs and micrometer included  
CFI 12.5x  
16  
CFI 15x  
14.5  
25  
CFI UW 10x  
LV-UEPI2  
CFI UW 10xM  
Mirometer eyepiece 10xN  
25  
Photomask included  
20  
Stroke 10 mm  
Main scale: 0.1 mm/increments  
Sub scale: 0.01 mm/increments  
LV-UV  
Polarizer  
LV-FLAN FL  
Analyzer  
YM-PO  
Polarizer Analyzer Prism  
L-AN  
L-DIC DIC L-DICH  
High-contrast  
DIC Prism  
Nosepieces  
Substages (LV150/LV150A)  
C-N6 Nosepiece L-NBD5 Nosepiece  
L-NU5  
Nosepiece  
(Universal)  
LV-NU5A Motorized  
Nosepiece (Universal)  
(Brightfield)  
(Bright/darkfield)  
LV-SUB Stage  
LV-SUB Stage 2  
Objective lenses  
Stages  
CFI LU PLAN FLUOR EPI series  
CFI L PLAN EPI CR series  
LV-S6 6x6 Stage  
LV-S64 6x4 Stage  
LV-S32 3x2 Stage  
Holders  
CFI LU PLAN FLUOR BD series  
For LV-S6 6x6 Stage  
For LV-S32 3x2 Stage  
Objective adapters  
LU objective  
Adapter M32-25  
C-OA 15mm Adapter  
L-S6WH Wafer  
Holder  
L-S6PL ESD Plate  
LV-S32PL  
ESD Plate  
LV-S32SGH  
Slideglass Holder  
Diascopic illumination condensers  
Micrometers  
Objective micrometer  
Eyepiece micrometer  
Grid micrometer  
LWD  
Slide  
C-C Abbe  
C-C Achro  
DF (Dry)  
Achromat  
(Swing-out??)  
Achromat  
2-100x  
14  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Digital cameras for microscopes  
Ultrahigh-definition Digital Camera  
The DXM1200F produces true-to-life, extremely high-quality images with up to approximately 12 million output pixels. It meets  
the demanding requirements of professional users and is excellent for image analysis in advanced R&D fields.  
The Digital Sight series is a powerful imaging system for monitoring/capturing images taken under brightfield,  
darkfield, DIC, epi-fluorescence, and other observation methods.  
Standalone type  
PC-connection type  
This type comes with an LCD monitor, making it  
convenient for on-screen monitoring without a PC and i
applications that require long/multiple exposures.  
This type requires connection to a PC and allows  
observation on a PC monitor, image capture,  
measurement and analysis when special application  
software, ACT-2U, is used.  
• Approx. 12 million output pixels comparable to film  
high-end cameras, thanks to Nikon’s exclusive micro-  
step high-density imaging technology  
Real imaging camera—DS-2Mv-L1  
• Live image display at 30fps max.  
• Image size: 1600 x 1200 pixels  
• 6.3” TFT monitor  
Real imaging camera—DS-2Mv-U1  
• Live image display at 12fps (800 x 560)  
• Live image display at a frame rate of 12 fps max.  
• Image size: 1600 x 1200 pixels  
• The wide exposure latitude produces true-to-life  
images regardless of brightness level.  
• Analog RGB output  
• CompactFlash card slot  
• USB mass-storage-class  
compatible  
• PC connection via USB2.0  
• Dedicated application software—ACT-2U  
• Direct print function (Pict  
bridge compatible)  
optional*1  
• Ethernet (100BASE/TX) port*2  
Camera control software  
*1: A CP900DC dedicated printer  
and C-mount adapter are  
necessary. Provided with real 10  
mode (10X printing).  
ACT-1  
time shooting.  
All essential sections, including live image preview, ᕢ  
captured image window, thumbnail, and image  
Option: camera control software  
Dedicated camera control  
software ACT-2U  
Minimizes fatigue during large-volume, extended  
*2: FTP Client/Server, HTTP Server Telnet Server functions provided.  
ACT-2  
The optional ACT-2U software offers the following  
capture parameter setting panel, are simultaneously  
Camera control software for DS-L1/DS-U1  
Scene mode—optimal imaging with a single mouse click  
Optimal imaging parameters have been preset for each sample type, therefore anyone, regardless of experience, can easily perform  
photography of the highest level.  
arrays of convenient measurement tools.  
displayed on a single screen, enabling users to easily  
understand image capture procedures. The size of the  
parameter setting panel has been reduced to leave more  
Two-point distance  
Scale  
Circumference/diameter  
Area  
space for image display.  
Wafer/IC chip  
Metal/ceramics  
PCB  
Point to line distance  
Intersection angle  
XY scale  
A host of measuring tools  
Two-point distance  
Scale  
Point to line distance  
Intersection angle  
Circumference/diameter  
Screen pattern (crossline, circle)  
Screen pattern  
(crossline, circle)  
Cross scale  
(DS-L1 only)  
Area (DS-U1 only)  
XY scale  
*Dedicated ACT-2U camera control software is necessary when using the DS-U1.  
Camera heads  
Select the best type to match your sample and use.  
For fluorescence observations  
(that require long exposure)  
For brightfield, darkfield, DIC observations  
DS-2MBW  
DS-5M  
DS-2MBWc  
DS-5Mc  
Image size: 1600 x 1200 pixels  
15 fps (30 max.)  
Superb movie  
Image size: 2560 x 1920 pixels  
True-to-life recording of minute  
images  
Image size: 1600 x 1200 pixels  
Sensitivity approx. 5 times greater Includes a Peltier device  
Image size: 2560 x 192pixels  
than predecessors  
Brilliant images with minimum noise  
Includes a Peltier device  
Brilliant images with minimum noise  
16  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Digital Camera  
Dimensional diagrams  
LV150A/LV150  
LV-TI3 Trinocular  
Tube ESD  
LV-TT2 Tilting  
Trinocular Tube  
LV-CR Column Riser 35  
95.5  
155  
35  
IN  
0
OUT  
100  
100  
0
φ10  
192.7  
65.5  
φ
φ
60  
50  
264.6  
66 31  
φ
52  
E.P.  
E.P.  
IN  
0
OUT  
100  
100  
0
φ
φ
51  
51  
60  
67  
202.5  
341  
250  
456.8  
90  
267.0  
LV-S6 6x6 Stage  
LV-S64 6x4 Stage  
LV-S32 3x2 Stage  
205  
129  
299  
140.5  
95.5  
227  
181  
LV100D  
JAPAN  
JAPAN  
317  
40  
31  
217  
299  
25.5  
25.5  
357  
317  
φ
34  
φ
34  
φ34  
109  
109  
109  
JAPAN  
341  
250  
LV-SUB Stage  
LV-SUB Stage 2  
LV-S32PL  
ESD Plate  
LV-S32SGH Slideglass  
Holder  
76  
151  
94  
50  
122  
122  
LV-UEPI Universal Epi-illuminator  
LV-UEPI2 Universal Epi-illuminator 2  
30  
66  
96  
54  
336  
295  
410.5  
106  
120  
370  
25.5  
110  
76.5  
13  
113.3  
300.5  
60  
276  
LV-NU5A  
LV-NCNT Nosepiece  
Controller  
LV-DIA Dia Dase  
250  
100  
250  
φ48  
Nosepiece  
φ21  
φ51  
336  
295  
410.5  
370  
ケーブル長  
25.5  
:定部より160mm  
110  
149  
55.7  
93.7  
116  
73.5  
Cable length 220mm  
(cord bush exit to connector exit)  
Cable length 220mm  
(cord bush exit to connector exit)  
13  
60  
115  
113.3  
300.5  
276  
55  
111  
341  
367  
φ21  
φ51  
18  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Polarizers/analyzers/plate  
Main specifications  
YM-PO Polarizer  
LV-PO Polarizer  
LV-UVPO Polarizer  
L-AN Analyzer  
85.4  
79  
85.4  
79  
85.4  
79  
90  
LV150/150A  
Main body  
Baseless type (spacer insertable between arm and stand); Max. sample height 47mm (when configured with 3x2 stage/6x4 stage),  
82mm with column riser, 116.5mm with Suruga Seiki B23-60CR; 12V-50W brightness control transformer built in  
Focusing section  
Coaxial coarse/fine focus knob, left: coarse/fine, right: fine; Stroke 40mm, coarse 14.0mm/rotation (torque adjustable, with  
refocusing mechanism), fine focusing 0.1mm/rotation (1mm/increments)  
LV-FLAN FL Analyzer  
LV-P Plate  
Nosepiece  
C-N6 Nosepiece (brightfield, sextuple), L-NBD5 Nosepiece (bright/darkfield quintuple, with flare prevention), L-NU5 Nosepiece  
(universal quintuple, with flare prevention), LV-NU5A Nosepiece (for LV150A, high-durability motorized universal quintuple, with  
flare prevention)  
113.5  
47  
Episcopic illuminator  
LV-U EPI  
12V-50W high-intensity halogen lamp (ESD-applied); Field (centerable) and aperture diaphragms synchronized with B/D  
changeover; ø25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer mountable  
90  
Episcopic illuminator  
LV-U EPI2  
12V-50W high-intensity halogen lamp (ESD-applied); 120W high-intensity mercury-fiber illuminator (with brightness  
control, no centering necessary) mountable; Centerable field and aperture diaphragms synchronized with B/D changeover;  
f25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer/l plate insertable, excitation balancer insertable  
Objective lenses  
Eyepiece tube  
Stage  
LV-TI3 Trinocular (erect image, F.O.V. 22/25), LV-TT2 Tilting Trinocular (erect image, F.O.V. 22/25), Y-TF Trinocular (inverted  
image, F.O.V 22/25), Y-TB Binocular (inverted image, F.O.V 22), C-TE Tilting Binocular (inverted image, F.O.V 22)  
CFI LU PLAN FLUOR  
LV-S32 3x2 Stage (stroke: 75x50 mm including glass plate), ESD-applied (excluding glass plate)  
LV-S64 6x4 Stage (stroke: 150x100 mm including glass plate), ESD-applied (excluding glass plate)  
LV-S6 6x6 Stage (stroke: 150x150 mm; only for episcopic illumination)  
CFI LU Plan Fluor EPI 5X  
CFI LU Plan Fluor EPI 10X  
CFI LU Plan Fluor EPI 20X  
CFI LU Plan Fluor EPI 50X  
CFI LU Plan Fluor EPI 100X  
φ30  
φ30  
φ29  
φ29  
φ29  
φ23.8  
φ23.8  
M25x0.75  
M25x0.75  
Eyepiece  
CFI eyepiece series  
CFI60 series  
φ23.8  
φ23.8  
φ23.8  
M25x0.75  
M25x0.75  
M25x0.75  
Objective lens  
Electrostatic decay time  
Power consumption  
Weight  
JAPAN  
JAPAN  
L.U  
L.U  
JAPAN  
1000-10V, within 0.2 sec.  
1.2A/75W  
JAPAN  
JAPAN  
5X / 15A  
WD23.5  
L.U  
L.U  
10X / 30A  
WD17.5  
L.U  
50X / 80A  
WD1.0  
100X / 90A  
20X / 45A  
WD4.5  
WD1.0  
Approx. 8.6kg  
φ8.5  
φ8.8  
φ17.5  
φ20  
φ9  
φ17.5  
φ21.8  
φ24  
φ18  
φ21.8  
φ24  
LV100D  
CFI LU PLAN FLUOR BD  
Main body  
Baseless type (spacer insertable between arm and stand); Max. sample height 29mm, 64mm with column riser; 12V-50W  
brightness control transformer built in  
CFI LU Plan Fluor BD 5X  
CFI LU Plan Fluor BD 10X  
CFI LU Plan Fluor BD 20X  
CFI LU Plan Fluor BD 50X  
CFI LU Plan Fluor BD 100X  
40.4  
40.4  
(Over head screw)  
φ36  
φ34  
φ36  
φ34  
φ36  
φ34  
(Over head screw)  
Focusing section  
Nosepiece  
Coaxial coarse/fine focus knob, left: coarse/fine, right: fine; Stroke 30mm, coarse 14.0mm/rotation (torque adjustable, with  
refocusing mechanism), fine focusing 0.1mm/rotation (1mm/increments)  
φ40  
φ35  
φ40  
φ35  
φ30.8  
M32x0.75  
φ30.8  
φ30.8  
M32x0.75  
M32x0.75  
φ30.8  
M32x0.75  
M32x0.75  
φ30.8  
C-N6 Nosepiece (brightfield, sextuple), L-NBD5 Nosepiece (bright/darkfield quintuple, with flare prevention), L-NU5 Nosepiece  
(universal quintuple, with flare prevention)  
JAPAN  
JAPAN  
L.U  
L.U  
JAPAN  
L.U  
JAPAN  
L.U  
JAPAN  
5X / 15A  
WD18  
10X / 30A  
WD15  
L.U  
Episcopic illuminator  
LV-U EPI  
12V-50W high-intensity halogen lamp (ESD-applied); Field (centerable) and aperture diaphragms synchronized with B/D  
changeover; f25mm filter (NCB11, ND16, ND4) insertable; Polarizer/analyzer insertable  
20X / 45 A  
WD4.5  
100X / 90 A  
WD1.0  
50X / 80 A  
WD1.0  
Episcopic illuminator  
LV-U EPI2  
12V-50W high-intensity halogen lamp (ESD-applied); 120W high-intensity mercury-fiber illuminator (with brightness control,  
no centering necessary) mountable; Centerable field and aperture diaphragms synchronized with B/D changeover; f25mm filter  
(NCB11, ND16, ND4) insertable; Polarizer/analyzer/l plate insertable, excitation balancer insertable  
φ27.6  
φ35.5  
φ26.2  
φ33.5  
φ25  
(φ28.4)  
φ37  
(φ28.4)  
φ37  
Diascopic illuminator  
Eyepiece tube  
Stage  
12V-50W high-intensity halogen lamp; Field (centerable) and aperture diaphragms synchronized with B/D changeover; Filters  
(ND8, NCB11) insertable  
CFI L PLAN EPI CR  
LV-TI3 Trinocular (erect image, F.O.V. 22/25), LV-TT2 Tilting Trinocular (erect image, F.O.V. 22/25), Y-TF Trinocular (inverted  
image, F.O.V 22/25), Y-TB Binocular (inverted image, F.O.V 22), C-TE Tilting Binocular (inverted image, F.O.V 22)  
CFI L PLAN EPI 100XCRB  
CFI L PLAN EPI 20XCR  
CFI L PLAN EPI 50XCR  
CFI L PLAN EPI 100XCRA  
φ35.5  
φ34  
φ33.5  
φ32  
φ35.5  
φ34  
φ35  
φ33.5  
φ29.5  
φ27.5  
LV-S32 3x2 Stage (stroke: 75x50 mm including glass plate)  
LV-S64 6x4 Stage (stroke: 150x100 mm including glass plate)  
φ29  
φ29.5  
φ28.5  
φ29.5  
φ28.5  
φ23.8  
M25x0.75-6g  
M25x0.75  
φ27  
M25x0.75  
φ23.8  
Eyepiece  
CFI eyepiece series  
CFI60 series  
Objective lens  
Electrostatic decay time  
Power consumption  
Weight  
L
50X / 0.70  
JAPAN  
L
100X / 0.35  
JAPAN  
L
1000-10V, within 0.2 sec.  
1.2A/75W  
100X / 0.35  
JAPAN  
L
20X/0.45  
JAPAN  
φ13  
φ18.8  
φ11.5  
φ19.8  
φ24.8  
φ14.5  
Approx. 9.4kg  
φ20  
φ31.5  
φ19.8  
φ24.8  
φ27  
φ23.3  
φ26  
φ31.5  
φ27  
φ32.5  
φ32.5  
20  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System diagram  
LV150 LV150A  
LV100D  
Camera Mount  
Camera Mount  
Filar Micrometer  
10xN  
Filar Micrometer  
10xN  
Eyepieces  
Eyepieces  
DXM1200F  
DS-5M DS-2M  
DXM1200F  
DS-5M DS-2M  
C-CT  
Centering  
Telescope  
C-CT  
Centering  
Telescope  
Photomicrographic  
System FX-III Series  
Photomicrographic  
System FX-III Series  
L-W  
L-W  
CFI UW  
10x M  
CFI UW  
10x M  
CFI UW  
10x  
CFI UW  
10x  
CFI  
10x  
CFI  
CFI  
CFI  
CFI  
15x  
CFI  
10x  
CFI  
CFI  
CFI  
CFI  
15x  
ENG-mount CCTV Camera  
C-mount CCTV Camera  
C-mount  
ENG-mount CCTV Camera  
C-mount CCTV Camera  
C-mount  
10x  
10x  
10xM 10xCM 12.5x  
10xM 10xCM 12.5x  
ESD  
ESD  
C-mount  
Zooming  
Adapter  
C-mount  
Zooming  
Adapter  
ENG-mount  
Zooming  
Adapter  
CCTV Adapters  
ENG-mount  
Zooming  
Adapter  
CCTV Adapters  
ENG-mount  
CCTV Adapter  
ENG-mount  
CCTV Adapter  
0.35x  
0.45x  
0.6x  
0.35x  
0.45x  
0.6x  
Adapter  
Adapter  
ENG-mount  
C-mount Direct  
CCTV Adapter  
ENG-mount  
C-mount Direct  
CCTV Adapter  
CCTV Adapters  
0.45x  
0.6x  
CCTV Adapters  
0.45x  
0.6x  
C-mount  
C-mount  
C-mount  
Adapter A  
0.7x  
C-mount  
Adapter A  
0.7x  
Projection  
Lenses  
PLI 2x  
0.7x  
Projection  
Lenses  
PLI 2x  
0.7x  
CCTV Adapter  
CCTV Adapter  
F.N.ø25  
F.N.ø25  
F.N.ø22  
E
F.N.ø22  
E
F
F
Relay  
Lens 1x  
Relay  
Lens 1x  
PLI 2.5x  
PLI 4x  
PLI 5x  
PLI 2.5x  
PLI 4x  
PLI 5x  
Relay  
Relay  
Zooming  
Lens  
Lens  
1x  
Zooming  
Lens  
Lens  
1x  
C-mount  
CCTV  
C-mount  
CCTV  
C-mount  
C-mount  
Adapter  
VM2.54x  
Adapter  
VM2.54x  
CCTV  
CCTV  
Adapter  
VM4x  
Adapter  
VM4x  
Epi-fluorescence Accessories  
Epi-fluorescence Accessories  
V-T Photo  
Adapter  
V-T Photo  
Adapter  
C-FL Fluorescence  
Filter Block  
C-FL Fluorescence  
Filter Block  
L-AN  
Analyzer  
YM-PO  
Polarizer  
D-FB Excitation  
Light Balancer  
L-AN  
Analyzer  
YM-PO  
Polarizer  
D-FB Excitation  
Light Balancer  
D-FB  
D-FB  
R
R
O
P
Q
Q'  
O
P
Q
Q'  
NCB Slider  
NCB Slider  
NCB11  
NCB11  
P'  
P'  
C-mount  
Adapter  
0.55x  
C-mount  
Adapter  
0.55x  
LV-PO  
LV-PO  
S
ND Slider  
S
ND Slider  
LV-FLAN FL Analyzer  
LV-FLAN FL Analyzer  
ND16  
ND4  
ND16  
ND4  
Polarizer  
Polarizer  
LV-TV TV Tube  
LV-TV TV Tube  
λ IN  
λ IN  
T
OUT  
T
OUT  
LV-λPλPlate  
LV-UVPO Polarizer  
LV-λPλPlate  
LV-UVPO Polarizer  
Intermediate Modules  
C-ER Eyelevel Riser  
Intermediate Modules  
C-ER Eyelevel Riser  
Eyepiece Tubes  
Eyepiece Tubes  
LV-TT2 Tilting  
LV-TT2 Tilting  
E
F
E
F
Trinocular Tube  
Trinocular Tube  
F
F
E
F
E
F
0.5x 2nd  
Objective  
0.5x 2nd  
Objective  
Y-TB  
Binocular Tube  
Y-TB  
Binocular Tube  
Y-IDP Double Port (1000 / 5545)  
Y-IDP Double Port (1000 / 5545)  
LV-TI3 Trinocular  
Tube ESD  
LV-TI3 Trinocular  
Tube ESD  
LV-UEPI Universal  
Epi-Illuminator  
LV-UEPI Universal  
Epi-Illuminator  
P
P
Other Eclipse series eyepiece  
tubes can be used.  
Other Eclipse series eyepiece  
tubes can be used.  
Y-IDP Double Port (1000 / 0100)  
Y-IDP Double Port (1000 / 0100)  
I
I
Q
Q
LV-UEPI2  
Universal  
S
LV-UEPI2  
S
Universal  
R
R
Epi-Illuminator 2 P'  
Epi-Illuminator 2 P'  
O
O
I’  
I’  
LV-CR Column Riser 35  
LV-CR Column Riser 35  
Q'  
Q'  
T
T
C-SP Simple  
Polarizing  
Polarizer  
S
S
B
A
A
LV-SUB Substage  
B
C
Condensers  
D-C  
Abbe  
C-C  
Achromat  
LWD  
Achromat  
Slide (Swing-out??)  
Achromat 2-100x  
Surugaseiki  
B23-60CR  
DF (dry)  
LV-SUB  
Substage 2  
I
Lamphouses  
LV-HL50W 12V-50W-LL  
Halogen Lamp  
C
LV-LH50PC  
Precentered Lamphouse  
Stages  
Lamphouses  
LV-HL50W 12V-50W-LL  
Halogen Lamp  
L-S6WH Wafer  
Holder  
L-S6PL  
ESD Plate  
Stages  
LV-S32SGH  
Slidegalss Holder  
LV-S32PL  
ESD Plate  
LV-S32SGH  
Slidegalss Holder  
LV-S32PL  
ESD Plate  
12V-100W  
Lamp  
I
I’  
LV-LH50PC  
Precentered Lamphouse  
D-LH 12V-100W Precentered  
Lamphouse (Requires  
TE2 External External Power  
Supply)  
POWER  
MIN.  
MAX.  
LV-S6  
6x6 Stage  
LV-S64  
6x4 Stage  
LV-S32  
3x2 Stage  
LV-S64  
LV-S32  
3x2 Stage  
12V-100W  
Lamp  
I
I’  
6x4 Stage  
100W TE2  
Power Supply  
POWER  
D-LH 12V-100W Precentered  
Lamphouse (Requires  
TE2 External Power Supply)  
MIN.  
MAX.  
POWER  
B
B
A
TE2-PS100W Power Supply  
(YM-EPI3 3-pin extension  
cord is required)  
I’  
MIN.  
MAX.  
Fiber  
100W TE2  
Power Supply  
C-HGF Fiber  
Adapter  
L-DIC DIC Prism  
L-DIC DIC Prism  
Nosepieces  
Nosepieces  
A
External Power Supply  
I’  
C-HGF Fiber  
Adapter  
Adapter  
Adapter  
L-DIHC High  
Contrast DIC Prism  
L-DIHC High  
Contrast DIC Prism  
LV-NU5A  
Motorized  
Nosepiece  
L-NBD5 DB5  
Nosepiece  
P-N P-N5  
Nosepiece  
L-NBD5 DB5  
Nosepiece  
P-N P-N5  
Nosepiece  
L-NU5 U5  
Nosepiece  
L-NU5 U5  
Nosepiece  
C-N C-N6  
Nosepiece  
C-N C-N6  
Nosepiece  
External Power Supply  
LU Nosepiece  
Adapter  
M32-25  
LU Nosepiece  
Adapter  
M32-25  
LU Plan Fluor  
BD Objective  
LU Plan Fluor  
BD Objective  
LU Plan Fluor  
EPI Objective  
LU Plan Fluor  
EPI Objective  
C-OA 15MM  
Adapter  
CFI L/LU  
EPI P  
Objective  
C-OA 15MM  
Adapter  
CFI L/LU  
EPI P  
Objective  
TI Objective Adapter  
TI Objective Adapter  
LV-NCNT  
Nosepiece  
Controller*  
LV-NCNT  
DI Objective  
DI Objective  
Nosepiece  
Controller Cable  
10m  
*Not necessary on the LV150A as the operation unit has been built into the main body.  
22  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Cooktop KM 2356 User Manual
Multiquip Trash Compactor HATZ1D81S 325 User Manual
NETGEAR Network Router CG814WG User Manual
Nilfisk ALTO Vacuum Cleaner SR 1301 P User Manual
North Star Pressure Washer M1573001A User Manual
Omega Vehicle Security Network Card OMG USB DIO48 User Manual
Oregon Scientific Portable Radio BAR383HG User Manual
Oregon Scientific Radar Detector WMR90A User Manual
Palsonic CRT Television 5120B User Manual
Patton electronic Network Card 1058DVs User Manual