FAQs
Applications
What are the primary applications for the Model 1058 VDSL Modem?
LAN Extension & Service Integration
Used in pairs (Central Office and Customer Premise), the Model 1058 establishes a high-
speed, line sharing, symmetrical 12.5 Mbps voice and data link. The Model 1058 inter-
connects two geographically separated LANs over a voice-grade twisted pair wire. Operation
is simple: packets destined for the remote LAN are sent transparently, at full line rate, to the
peered LAN. The Model 1058DVs built-in splitter allows users to simultaneously talk on the
phone while surfing the web, downloading files or receiving e-mails.
Other Applications include:
·
·
·
MTU/MDU Integrated Services (Voice and Data)
Network Backbones
Hybrid Copper-Fiber Infrastructure
·
Fiber To The Closet/VDSL to the desktop
Fiber To The Curb (FTTC)/VDSL to the home
·
·
·
·
Remote Workstations and Equipment
ISP Last Mile Extension
Remote Medical Imaging
1
Download from Www.Somanuals.com. All Manuals Search And Download.
FAQs
What are the distance limitations of the Model 1058 using different gauge
wires?
Using 24 AWG (0.5 mm) wire, the Model 1058 is capable of providing Ethernet extensions up
to 4,656 ft (1.42 km) including the potential 328 ft (100 m) Ethernet connections on both
ends of the communications link. Using 26 AWG (0.4 mm) wire, the Model 1058 is capable of
providing Ethernet extensions up to 3,856 ft (1.18 km). Actual distance and link performance
will vary based on the environment (cross talk/noise) and type/gauge of wire used. The chart
below shows an example of how the gauge of wire affects the distance.
Wire Gauge: AWG (mm)
26 AWG (0.4 mm)
24 AWG (0.5 mm)
22 AWG (0.64 mm)
20 AWG (0.81 mm)
18 AWG (1.0 mm)
16 AWG (1.29 mm)
Distance: Feet (km)
3856’ (1.18 km)
4656’ (1.42 km)
5256’ (1.60 km)
5556’ (1.69 km)
5756’ (1.75 km)
5856’ (1.78 km)
*NOTE: Distances are based on a minimum to no cross talk environment. This distance table includes
the potential 328ft (100 m) Ethernet connections on both ends of the communications link.
Can the line rate be altered on the Model 1058 to achieve lower bandwidths
and/or longer distances?
No, the line rate is factory configured at 12.5Mbps. Please inquire for special factory
configurations.
Can the Model 1058 be configured for symmetrical or asymmetrical
transmission from the field?
No, the Model 1058 is factory configured for symmetrical transmission only. Please inquire for
asymmetrical versions.
Does the Model 1058 operate in pairs?
Yes, the Model 1058 must operate in pairs. For each link, a Central Office (1058D/CO or
1058DV/CO) and Customer Premise (1058D/CP or 1058DV/CP) unit is required.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
FAQs
Which end of the link should the “CO” Central Office unit and “CP” Customer
Premise unit be located?
The Model 1058D/CO or 1058DV/CO and 1058D/CP or 1058DV/CP should be located according
to their descriptions. The CO should to be placed at the Central Office and the CP should be
placed at the Customer Premise due to special filtering for each application.
Does the Patton Model 1058 support VLAN or WLAN?
The Model 1058 does not support WLAN (802.11). The Model 1058 will support VLAN
(802.1Q) by passing the larger sized packets transparently. The Model 1058 does not have
configuration commands to add a VLAN tag to a packet.
Does the Patton Model 1058 pass higher layer protocol such as TCP/IP
packets?
Yes, the Model 1058 does pass higher layer protocols such as TCP/IP. The Model 1058 does
not read the TCP/IP packets, but will pass the packets on transparently.
Is the Model 1058 capable of bridging?
Yes, the Model 1058 will automatically learn, age, and filter 32 source addresses. Destination
addresses of incoming frames are compared with the Source Address in the address table and
discarded if an entry exists; otherwise, they are forwarded over the VDSL link.
Can voice and data be used simultaneously?
Yes, voice and data can be used simultaneously.
Will the POTS/ISDN port on the Model 1058DV operate without power?
The built-in POTS/ISDN Splitter (1058DV only) is a passive element and does not require
power to operate. The POTS/ISDN port is able to provide a “life-line” telephone link provided
the physical connection between the CO and CP VDSL modems is still intact.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
FAQs
Ethernet (10 or 100Base-T) Interface
What devices typically connect to the Ethernet 10/100Base-T port?
Devices that typically connect to the Ethernet port are Ethernet Hubs/Switches, Remote PC’s,
and any other network enabled device.
How is the Ethernet port configured to accept 10 or 100Base-T?
There is absolutely no configuration necessary. The Ethernet port automatically senses 10 or
100Base-T Ethernet connections.
Does the Ethernet port require configuration for full or half-duplex
connections?
The Model 1058 will automatically sense full or half-duplex Ethernet connections.
Power Supply
What are the power supply options for the Model 1058’s?
The Model 1058’s come standard with an external 120VAC or UI (100-240VAC) power supply.
–48, -24, or -12VDC power supplies are optional.
5