Black Box Network Hardware EncrypTight Enforcement Point ETEP Installation Guide User Manual

ET0010A  
ET0100A  
ET1000A  
EncrypTight Enforcement Point (ETEP) Installation Guide  
EncrypTight acts as a transparent overlay that  
integrates easily into any existing network  
architecture, providing encryption rules and keys  
to EncrypTight Enforcement Points.  
EncrypTight consists of a suite of tools that performs various tasks of  
appliance and policy management, including Policy Manager (PM),  
Key Management System (KMS), and EncrypTight Enforcement Points  
(ETEPs).  
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)  
Customer  
Support  
Information  
FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746  
Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
4
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
6
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
About This Document  
Purpose  
The ET VSE-series Installation Guide describes how to cable and install the Black Box™ ETEP  
EncrypTight Enforcement Points.  
Intended audience  
This document is intended for use by network technicians and security administrators who are familiar  
with setting up and maintaining network equipment.  
Assumptions  
This document assumes that its readers have an understanding of the following:  
Basic principles of TCP/IP networking, including IP addressing, switching and routing.  
Personal computer (PC) operation and common PC terminology  
Terminal emulation software and FTP operations.  
Conventions used in this document  
Bold  
Indicates one of the following:  
a menu title  
the name of a command  
the name of a parameter  
Italics  
Indicates a new term  
Monospaced  
Monospaced bold  
Indicates machine text, such as terminal output or a file name  
Indicates a command to be issued by the user  
Contacting Black Box Technical Support  
Contact our FREE technical support, 24 hours a day, 7 days a week:  
Phone  
Fax  
724-746-5500  
724-746-0746  
e-mail  
Web site  
ETEP Installation Guide  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
About This Document  
8
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1 Product Overview  
This section includes the following topics:  
ETEP Introduction  
The EncrypTight Enforcement Point (ETEP) Variable Speed Encryptors (VSEs) are purpose-built  
encryption appliances that provide multi-layer data protection. With straightforward setup and  
configuration, the ETEP has the flexibility to provide Ethernet frame encryption for Layer 2 networks, IP  
packet encryption for Layer 3 networks, and Layer 4 data payload encryption for MPLS networks.  
The ETEP’s variable speed capability lets you enable just the bandwidth you need, using a software  
license. As your bandwidth needs increase, simply update your license. No need to replace your  
hardware. The ET VSE-series offer full-duplex, line rate encryption from 3 Mbps to 1 Gbps using the  
AES-256 encryption algorithm.  
ETEP Installation Guide  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Product Overview  
Figure 1  
Multipoint Ethernet Encryption using EncrypTight  
The ETEP interfaces with network equipment through two data ports, the local port and the remote port.  
Unencrypted traffic that originates from a trusted, local network is received on the local port, where the  
ETEP applies security processing to it. The encrypted traffic is then sent from the remote port to an  
untrusted network such as the Internet. At the opposite endpoint the process is reversed. Encrypted traffic  
is received on the ETEP remote port and decrypted. Then the decrypted traffic is sent from the local port  
to the destination.  
The ETEP is managed in-line or out-of-band through a dedicated Ethernet management interface. The  
ETEP can be managed in two ways, depending on the size and complexity of your deployment:  
Command Line Interface (CLI)  
The CLI is all you need to manage a standalone deployment, typically a pair of ETEPs. CLI  
commands are available to perform initial setup of the ETEP, along with diagnostic and  
troubleshooting commands. In Layer 2 deployments, you can configure the ETEPs for operation and  
create Layer 2 point-to-point policies using the CLI commands.  
EncrypTight Policy and Key Manager™  
EncrypTight is an application for managing group encryption deployments. EncrypTight separates the  
functions of policy management, key generation and distribution, and policy enforcement. As a result,  
multiple ETEPs can use common keys. This works for complex mesh, hub and spoke, and multicast  
networks, as well as in straightforward point-to-point topologies. Figure 1 shows ETEPs deployed in a  
multipoint Ethernet network.  
EncrypTight includes the following components:  
EncrypTight Element Management System (ETEMS) for appliance configuration and management  
EncrypTight Policy Manager (ETPM) for policy definition and deployment  
EncrypTight Key Management System (ETKMS) for key generation and distribution  
10  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ET0010A Physical Description  
ET0010A Physical Description  
The ET0010A is a rack-mountable encryptor that can run at speeds ranging from 3-50 Mbps. It has three  
data ports on the front panel labeled Remote, Local, and Aux1. The following sections describe the  
ET0010A connectors and LED indicators.  
Front Panel Connectors  
The ET0010A front panel connectors are shown in Figure 2.  
Figure 2  
ET0010A Front Panel Connectors  
Elements in Figure 2:  
1)  
2)  
3)  
4)  
5)  
RS-232 management port  
Ethernet management port  
Auxiliary port (not enabled in this release)  
Remote port (encrypted traffic):  
Local port (clear traffic):  
ETEP Installation Guide  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Product Overview  
Status Indicators  
The ET0010A status indictors are shown in Figure 3. The status indications are described in Table 1.  
Figure 3 ET0010A Status Indicators  
Elements of Figure 3:  
1)  
2)  
3)  
4)  
Power LED  
Alarm LED  
Status indicators  
Link indicators  
The following table describes how to interpret the ET0010A status indicators.  
Table 1 ET0010A Status Indicators  
Indicator Light  
Power (green)  
State  
Off  
Indication  
Unit is powered off.  
On  
Unit is powered on.  
10/100 link status  
(green)  
Off  
Loss of signal on the 10/100 link.  
a
On  
The 10/100 link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the 10/100 link.  
Loss of signal on the Gigabit link.  
Blinking  
Off  
Gigabit link status  
(amber)  
On  
The Gigabit link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the Gigabit link.  
Normal operation.  
Blinking  
Off  
Alarm (green)  
On  
The unit is in an error state. This occurs when the  
diagnostics detect a boot failure, a critical error threshold is  
exceeded, or a FIPS test fails when the ETEP is in FIPS  
mode.  
Status (1,2,3,4)  
Off  
On  
Unit is up and operational.  
Displays diagnostic codes during boot up.  
a. The link status LEDs are on the remote and local data ports, Ethernet management port, and Aux1 port.  
12  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
ET0100A Physical Description  
Rear Panel  
The ET0010A rear panel and external power supply are shown in Figure 4.  
Figure 4 ET0010A Rear Panel and External Power Supply  
Elements of Figure 4:  
1)  
2)  
External power supply power connector  
Rear panel power connector  
ET0100A Physical Description  
The ET0100A is a rack-mountable encryptor that can run at speeds ranging from 100–250 Mbps. The  
following sections describe the connectors and LED indicators that appear on the front and rear panels of  
the ET0100A.  
ETEP Installation Guide  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Product Overview  
Front Panel Connectors  
The ET0100A front panel connectors are shown in Figure 5.  
Figure 5  
ET0100A Front Panel Connectors  
Elements of Figure 5:  
1)  
2)  
3)  
4)  
10/100 Ethernet management port  
RS-232 port  
Remote port (encrypted traffic)  
Local port (clear traffic)  
LED Indicators  
The ET0100A LED indictors are shown in Figure 6. The LED indications are described in Table 2.  
Figure 6 ET0100A LED Indicators  
Elements of Figure 6:  
1)  
2)  
3)  
4)  
Diagnostic display  
Alarm LED  
Link indicators  
Power indictor  
14  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
ET0100A Physical Description  
The following table describes how to interpret the LEDs on the ET0100A front panel.  
Table 2 ET0100A Front Panel LED Indicators  
Indicator Light  
State  
Off  
Indication  
Power (green)  
Unit is powered off.  
Unit is powered on.  
Loss of signal on the 10/100 link.  
On  
Ethernet port status  
Off  
a
(green)  
On  
The link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the 10/100 link.  
Loss of signal on the Gigabit link.  
Blinking  
Off  
Gigabit link status (amber)  
Alarm (green)  
On  
The Gigabit link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the Gigabit link.  
Normal operation.  
Blinking  
Off  
On  
The unit is in an error state. This occurs when the  
diagnostics detect a boot failure, a critical error threshold is  
exceeded, or a FIPS test fails when the ETEP is in FIPS  
mode.  
Diagnostic code display  
On  
Displays diagnostic codes during boot up. After boot up, it  
reflects the operational state of the appliance and error  
conditions.  
a. The link status LEDs are on the remote and local data ports, and Ethernet management port.  
Rear Panel  
The ET0100A rear panel is shown in Figure 7.  
Figure 7 ET0100A Rear Panel  
Elements of Figure 7:  
1)  
2)  
3)  
Power receptacle  
Fan  
Product ID label  
ETEP Installation Guide  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Product Overview  
ET1000A Physical Description  
The ET1000A is a rack-mountable 1 Gbps encryptor with dual power supplies. It can operate at speeds  
ranging from 500 Mbps–1 Gbps. The following sections describe the ET1000A connectors and LED  
indicators.  
Front Panel Connectors  
The ET1000A front panel connectors are shown in Figure 8.  
Figure 8  
ET1000A Front Panel Connectors  
Elements of Figure 8:  
1)  
2)  
3)  
4)  
5)  
6)  
RS-232 serial port  
10/100 Ethernet management port  
Gigabit Ethernet management port (not enabled in this release)  
Aux1 port (not enabled in this release)  
Remote port (encrypted traffic)  
Local port (clear traffic)  
LED Indicators  
The ET1000A LED indicators are shown in Figure 9. The LEDs are described in Table 3.  
16  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
ET1000A Physical Description  
Figure 9  
ET1000A LED Indicators  
Elements of Figure 9:  
1)  
2)  
3)  
4)  
5)  
6)  
7)  
Power LED  
Alarm LED  
Diagnostic display  
Link indicators: 10/100 Ethernet management port  
Link indicators: Gigabit management port  
Link indicators: Aux1, Remote and Local ports  
Power supply status LEDs  
Table 3 describes how to interpret the LEDs on the ET1000A front panel.  
Table 3 ET1000A Front Panel LED Indicators  
Indicator Light  
State  
Off  
Indication  
Power (green)  
Unit is powered off.  
Unit is powered on.  
Normal operation.  
On  
Alarm (green)  
Off  
On  
The unit is in an error state. This occurs when the  
diagnostics detect a boot failure, a critical error threshold is  
exceeded, or a FIPS test fails.  
Diagnostic code display  
10/100 link status (green)  
On  
Displays diagnostic codes during boot up. After boot up, it  
reflects the operational state of the appliance and error  
conditions.  
Off  
Loss of signal on the 10/100 link.  
On  
The 10/100 link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the 10/100 link.  
Loss of signal on the Gigabit link.  
Blinking  
Off  
a
Gigabit link status (green)  
On  
The Gigabit link is up but no traffic is passing over the link.  
Indicates the presence of traffic on the Gigabit link.  
Blinking  
Off  
Power supply status  
Power supply is not operational. Possible causes include  
power supply unplugged, power supply removed from  
chassis, or a malfunction.  
On  
Power supply is operational.  
a. Gigabit links include the remote and local data ports, gigabit Ethernet management port, and Aux1 port.  
ETEP Installation Guide  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Product Overview  
Rear Panel  
The ET1000A rear panel is shown in Figure 10.  
Figure 10 ET1000A Rear Panel  
Elements of Figure 10:  
Power Supply # 2  
1)  
2)  
3)  
4)  
Release lever for power supply 2  
Power supply 2 receptacle  
Power cord clip for power supply 2  
Status LED for power supply 2. Green indicates normal operation. Red indicates a  
power fail state.  
Power Supply # 1  
5)  
6)  
Power cord clip for power supply 1  
Status LED for power supply 1. Green indicates normal operation. Red indicates a  
power fail state.  
7)  
8)  
Release lever for power supply 1  
Power supply 1 receptacle  
18  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Features  
Features  
ETEPs share many of the same features and capabilities across hardware models, as shown in Table 5.  
Hardware differences between the ETEP models are summarized in Table 4.  
Table 4  
ETEP Hardware Comparison  
Dual  
Power  
Supplies  
Form  
Factor  
Data Port  
Speed  
Data Port  
Interface  
Mgmt Port  
Interface  
Auxiliary  
port  
Model  
ET0010A  
1u rack-  
mount  
(2) 3–50  
Mbps  
RJ-45  
RJ-45  
SFP  
RJ-45  
Yes  
No  
ET0100A  
ET1000A  
1u rack-  
mount  
(2) 100–  
250 Mbps  
RJ-45  
No  
No  
1u rack-  
mount  
(2) 500–  
1000 Mbps  
RJ-45 and  
SFP  
Yes  
Yes  
The ETEP features are summarized in Table 5.  
Table 5  
Category  
Throughput  
ETEP Feature Summary  
Feature  
ET0010A: Supports encrypted throughput rates of 3, 6, 10, 25  
and 50 Mbps  
ET0100A: Supports encrypted throughput rates of 100, 155, and  
250 Mbps  
ET1000A: Supports encrypted throughput rates of 500, 650, and  
1000 Mbps  
Encryption Support  
Advanced Encryption Standard (AES): FIPS 197 (256 bit keys)  
3DES: ANSI X9.52 (168 bit keys), standard CBC mode  
User-configurable for Layer 2 Ethernet or Layer 3 IP encryption,  
with option to encrypt only the Layer 4 payload  
Authentication Methods  
Encapsulation Modes  
Device Management  
X.509 v3 digital certificates (management interface)  
HMAC-SHA-1-96  
HMAC-MD5-96  
Layer 2: Ethernet payload encryption  
Layer 3: IPSec Tunnel mode with original IP header preservation  
IPSec Transport mode for Layer 4 payload encryption option  
EncrypTight software for device and policy management  
Out-of-band management  
Alarm condition detection and reporting  
Syslog support  
SNMPv2c and SNMPv3 managed object support  
Audit logging  
Management access using X.509 v3 digital certificates  
Security options include TLS, SSH, IKE/IPsec  
ETEP Installation Guide  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Product Overview  
Table 5  
ETEP Feature Summary  
Feature  
Category  
Network Support  
Ethernet  
VLAN tag preservation  
MPLS tag preservation  
Jumbo frame support (ET0100A, CEP100-XSA, CEP1000,  
ET1000A)  
Link state pass-through  
IPv4  
IPv6 (Layer 2 Ethernet encryption mode)  
NTP  
Host or gateway packet reassembly option  
Source or destination IP address  
Source or destination port number  
Protocol ID (Layer 3 IP packet and Layer 4 payload options)  
VLAN ID (Layer 2 encryption option)  
Multicast address  
Policy Selector Options  
Specifications  
This section lists the mechanical and environmental specifications for the following ETEP models:  
ET0010A specifications are listed in Table 6  
ET0100A specifications are listed in Table 7  
ET1000A specifications are listed in Table 8  
Table 6  
Category  
Interfaces  
ET0010A Mechanical and Environmental Specifications  
Specification  
(2) 10/100 Mbps Ethernet ports for encrypting and decrypting  
traffic  
(1) 10/100 Mbps Ethernet auxiliary port (ET0010A only, not  
enabled)  
10/100/1000 Mbps auto-sensing Ethernet LAN port for  
management  
RS-232 port for management  
20  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Specifications  
Table 6  
Category  
ET0010A  
ET0010A Mechanical and Environmental Specifications  
Specification  
19 inch rack mount design  
Electrical/Mechanical Dimensions  
1u tamper evident chassis  
Dimensions: 1.6” H x 8.0” W x 5.8” D  
Weight (without external power supply),1 pound 4 ounces  
External power supply:  
Weight: 11 ounces  
Input voltage: 100-240 VAC @ 1.5 amps, 50/60 Hz, auto-  
sensing  
Output voltage: 12 VDC @ 5 amps  
Nominal input current: 0.25 amps  
Nominal power dissipation: 36 watts  
Thermal power: In-rush 102 BTU/hour, steady state 102 BTU/  
hour  
Environmental  
Regulatory  
Operating temperature: 0 to 40 degrees C (32 to 104 degrees F)  
Operating humidity: Up to 90% (non-condensing)  
Operating altitude: -200 to 10,000 feet AMSL  
Table 7  
ET0100A Mechanical and Environmental Specifications  
Category  
Specification  
Interfaces  
(2) 10/100/1000 Mbps Ethernet ports for encrypting and decrypting  
traffic  
10/100 Mbps auto-sensing Ethernet LAN port for management  
RS-232C port for management  
Electrical/Mechanical  
Dimensions  
19 inch rack mount design  
1U tamper evident chassis  
Dimensions: 1.75” H x 17” W x 10” D  
Weight: 6 pounds  
100-240 VAC @ 4 amps, 50/60 Hz, auto-sensing  
Nominal input current: 1.0A  
Nominal power dissipation: 65 watts  
Thermal power: In-rush 380 BTU/hour, steady state 140 BTU/hour  
Operating temperature: 0 to 40 degrees C (32 to 104 degrees F)  
Operating humidity: Up to 90% (non-condensing)  
Operating altitude: -200 to 10,000 feet AMSL  
Environmental  
Regulatory  
ETEP Installation Guide  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Product Overview  
Table 8  
ET1000A Mechanical and Environmental Specifications  
Specification  
Category  
Interfaces  
(2) Gigabit Ethernet ports for encrypting and decrypting traffic  
(single mode, multimode, or copper)  
10/100 Mbps auto-sensing Ethernet LAN port for management  
RS-232C port for management  
(1) Auxiliary Gigabit port for data traffic (not enabled)  
(1) Gigabit Ethernet port for management (not enabled)  
19 inch rack mount design  
ET1000A  
Electrical/Mechanical  
Dimensions  
1U tamper evident chassis  
Dimensions: 1.75” H x 17” W x 15.5” D  
Weight: 10 pounds  
100-240 VAC @ 3-1.5A, 47-63 Hz, auto-sensing  
Nominal input power: 72 watts  
Maximum power: 90 watts  
Nominal input current: 0.65 A @ 110V  
Thermal power, single power supply: In-rush 266 BTU/hour, steady  
state 222 BTU/hour  
Thermal power, dual power supplies: In-rush 440 BTU/hour, steady  
state 263 BTU/hour  
Environmental  
Regulatory  
Operating temperature: 0 to 40 degrees C (32 to 104 degrees F)  
Operating humidity: Up to 90% (non-condensing)  
Operating altitude: -200 to 10,000 feet AMSL  
22  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
2 Installation  
This section includes the following topics:  
Before You Start  
Before you prepare the ETEP for installation, review the following information:  
Safety Guidelines  
The ETEP does not contain any field-replaceable internal parts. Do not remove the unit’s cover for any  
reason. The cover is to be removed only by authorized Black Box service personnel.  
Authorized service personnel should review the following safety information prior to performing service  
or maintenance procedures on the ETEP.  
CAUTION  
Disconnect all power cords before servicing.  
ETEP Installation Guide  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Installation  
WARNING  
The ETEP contains a lithium battery, which users should not attempt to replace. Battery replacement must  
be performed by qualified Black Box personnel. Risk of explosion if battery is replaced by an incorrect  
type. Used batteries should be disposed of according to the manufacturer’s instructions.  
CAUTION  
Electrostatic discharge (ESD) can damage electronic components and equipment. ESD occurs when  
electronic components are improperly handled and can result in complete or intermittent failures. Always  
follow ESD-prevention procedures when removing and replacing components.  
Qualified service personnel should use the following guidelines to prevent ESD damage:  
Always use an ESD wrist or ankle strap and ensure that it makes skin contact.  
Connect the equipment end of the strap to an unpainted metal chassis surface.  
If no wrist strap is available, ground yourself by touching the metal chassis.  
Software Requirements  
ETEP software is factory installed on the appliance. A backup copy of the software is provided on the  
ETEP CD. To learn how to reinstall your software or install an update, refer to the user guide for your  
management software.  
If you are using EncrypTight to manage your ETEPs, you will need to install the EncrypTight software  
on the management station to configure the ETEPs for network operation and to create and deploy  
policies. See the EncrypTight User Guide for more information about using ETEPs in a EncrypTight  
deployment.  
The third party software listed in Table 9 is used when managing the ETEP in a standalone deployment.  
See the EncrypTight User Guide for additional third party software you may want to install when using in  
EncrypTight to manage EncrypTight appliances.  
Table 9  
Software  
FTP server  
Third party management station software  
How it’s used  
Vendor  
Copies files to and from  
EncrypTight appliances,  
including log files and new  
firmware  
Microsoft FTP server, included  
with Windows XP  
SFTP server (optional: available  
with ETEP 1.6 and later)  
Secures file transfers to and  
from EncrypTight appliances  
Cerberus FTP Server 4 –  
Professional Edition  
PDF reader  
Opens the user documentation  
files on the product CD  
Adobe Acrobat Reader version  
6.0 or higher. Free download  
available from www.adobe.com.  
SSH client (ETEPs)  
Securely connects to the ETEP  
CLI  
PuTTY, included with the  
ETEMS installation  
24  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Before You Start  
ETEP Site Preparation  
Most ETEP models can be mounted in a standard 19-inch rack using the supplied mounting kit, or simply  
placed on a rack shelf or solid surface. Before installing the ETEP in a 19-inch rack, consider the  
following guidelines:  
Ambient temperature  
Install the ETEP in an environment compatible with the 40ºC maximum recommended ambient  
temperature. Extra clearance above or below the unit on the rack is not required; however, be aware  
that equipment placed in the rack beneath the ETEP can add to the heat load. Therefore, avoid  
installing in an overly congested rack. Air flowing to or from other equipment in the rack might  
interfere with the normal flow of cooling air through the ETEP, increasing the potential for  
overheating.  
Air flow  
Make sure that there is sufficient flow of air around the ETEP so that safe operation is not  
compromised. Maintain a clearance of at least 3 inches (7.62 cm) at the sides of the ETEP to ensure  
adequate air intake and exhaust. If installing in an enclosed rack, make sure the rack has adequate  
ventilation or an exhaust fan. An enclosed rack with a ventilation system that is too powerful can  
prevent proper cooling by creating negative air pressure around the ETEP.  
Mechanical Loading  
Keep the center of gravity in the rack as low as possible. This ensures that the weight of the ETEP  
will not make the rack unstable. Make sure that the rack is secured and use the proper mounting  
hardware to secure the ETEP to the rack.  
Circuit Loading  
Consider the connection of the ETEP to the supply circuit and the effect that overloading of circuits  
might have on overcurrent protection and supply wiring. Consult the voltage and amperage ratings on  
the UL label affixed to the unit’s rear panel when addressing this concern.  
Grounding  
Maintain reliable grounding of a rack-mounted ETEP. Pay particular attention to supply connections  
other than direct connections to the branch circuit, such as the use of power strips.  
Maintenance  
Allow at least 19 inches (48.3 cm) of clearance at the front of the rack for maintenance. Use a cable-  
management system to help keep cables organized, out of the way, and free from kinks or bends that  
degrade cable performance.  
ETEP Installation Guide  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
Firewall Ports  
Table 10 lists the protocols that are used by the ETEPs and the EncrypTight system. Make sure that any  
firewalls in your system are configured to allow for the protocols that are required for your deployment:  
standalone ETEPs used for point-to-point encryption or ETEPs used in an EncrypTight system.  
Table 10  
Firewall ports  
Standalone  
ETEPs  
Cipher-  
Engine  
Protocol  
Port  
Description  
FTP  
TCP 20,  
21  
Used for upgrading the software on the  
ETEP and retrieving appliance log files.  
Yes  
Yes  
ICMP/Ping  
Used to check connectivity with a device.  
Yes  
Yes  
Yes  
IKE /  
ISAKMP  
UDP 500  
Used to establish security associations in  
IKE policies.  
IPSec ESP  
IP  
protocol  
50  
Used in encryption policies.  
Yes  
Yes  
Yes  
SFTP  
TCP 22  
Used for secure FTP operations.  
Yes  
Yes  
SNMP  
UDP  
161, 162  
Used to send SNMP traps from the ETEPs  
to a management workstation.  
SNTP  
UDP 123  
Used for time synchronization among  
EncrypTight components.  
Yes  
SSH  
TCP 22  
Used to securely access the CLI on ETEPs.  
Yes  
Yes  
Yes  
Syslog  
UDP 514  
Used to send syslog messages from the  
ETEPs to a syslog server.  
TLS  
(HTTPS)  
TCP 443  
TCP 443  
A secure method of communicating  
management information between ETEMS  
and the ETEPs.  
Yes  
Yes  
XML-RPC  
Used for communications between  
EncrypTight components.  
Installing the ET0010A  
This section describes how to install ET0010A. To prepare the ET0010A for installation, review the  
installation steps in Table 11, unpack the shipping carton, and prepare a space for the installation of the  
appliance.  
26  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installing the ET0010A  
The steps to perform for a typical installation are listed below.  
Table 11  
Installation Steps  
Step  
Action to Perform  
Description  
1
2
3
4
5
Review the cabling requirements.  
Unpack the shipping package.  
Install the ETEP in a rack or on a solid surface.  
Connect the cables.  
Apply power to the ETEP.  
Cabling Requirements: ET0010A  
Table 12 outlines the standard cables used with each port on the ETEP. The connector type listed  
indicates only what is required to connect to the ETEP port, and may or may not be the same connector  
type required for the other end of the cable. Some cables are supplied by Black Box and others are user-  
supplied.  
Table 12  
ETEP Port  
ET0010A Standard Cables  
Cabling  
Supplied by...  
Black Box  
Power receptacle  
RS-232 port  
Power supply and power cable  
1.8 meter shielded null modem  
cable with an RJ45 connector at  
one end and a DB9 female  
Black Box  
connector at the opposite end.  
Ethernet Management Port  
Unshielded Category 5 straight  
through cable (UTP), RJ-45  
connectora.  
Black Box  
Aux1 port  
Not applicable. Port is not  
enabled in this release.  
Not applicable  
User  
Remote and Local ports  
(2) Unshielded Category 5  
straight through cables (UTP),  
a
RJ-45 connector  
a. The local, remote, and Ethernet management ports are auto-sensing for polarity. You can use shielded Category 5  
straight through cables or crossover cables when connecting to these ports.  
Unpacking the Shipping Carton: ET0010A  
Remove all product components from the shipping carton and compare the contents to the packing list.  
Keep all packaging in case it is necessary to return the unit.  
The ETEP is packaged with the standard items listed below. Additional cables, country-specific power  
cords, and other accessories can be ordered separately.  
1
2
ET0010A  
Firmware and software is factory-installed on the unit.  
Accessory Kit  
(1) Power cable (US)  
(1) Power supply  
ETEP Installation Guide  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installation  
(1) Shielded null modem cable with an RJ-45 connector at one end and a DB-9 female connector  
at the opposite end.  
(1) Unshielded Category 5 straight through cable (UTP) with RJ-45 connectors  
Rack mount kit includes 2 mounting brackets, 4 large screws (#10-32), and 4 small black screws.  
The kit also includes 4 rubber feet and 4 small silver-toned screws with built-in washers for solid  
surface installations (see Figure 11).  
CD containing user documentation and a backup copy of the ETEP software  
Figure 11 Accessory screws and feet  
Elements of Figure 11:  
1)  
2)  
3)  
4)  
Large screws (#10-32), used to attach the mounting brackets to the rack  
Small black screws, used to attach the mounting brackets to the ETEP  
Rubber feet, used for solid surface installation  
Small silver-toned screws with built in washers, used to attach rubber feet to the  
bottom of the ETEP  
Installation Instructions: ET0010A  
The ET0010A can be mounted in a standard 19-inch rack using the mounting kit, or simply placed on a  
rack shelf or solid surface. Before installing the ETEP in a 19-inch rack, review the mounting guidelines  
Rack Mount Installation  
To mount the ETEP in a standard 19-inch equipment rack, have the following tools and materials  
available:  
28  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the ET0010A  
External power supply  
Two mounting brackets, supplied in the Accessory Kit  
(4) small black screws and (4) large #10-32 screws, supplied in the Accessory Kit  
#1 Phillips and #2 Phillips screwdrivers (user-supplied)  
To install the ETEP in a rack:  
Place the unit on a solid surface, with the bottom panel facing up.  
1
When looking at the ET0010A from the bottom rear, the bracket that holds the power supply is on the  
right, as shown in Figure 12.  
Figure 12 Bottom rear view of the ET0010A, with rack mount brackets  
Elements of Figure 12:  
1)  
2)  
3)  
4)  
5)  
6)  
Mounting bracket  
Regulatory label on the bottom of the unit  
Rear panel  
Power supply connector  
Mounting bracket with power supply cradle  
Front panel  
2
Attach the mounting brackets to each side of the unit using the four small black screws provided in  
the Accessory Kit (item 2 in Figure 11), and a #1 Phillips screwdriver.  
When looking at the ET0010A from the bottom rear, the bracket that holds the power supply is on the  
right, as shown in Figure 13.  
ETEP Installation Guide  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Figure 13 Attach mounting brackets to the bottom panel. ET0010A is shown below.  
3
Turn the ETEP face up and locate the external power supply. With the label side facing down, place  
the power supply in the mounting bracket cradle and snap it into place, as shown in Figure 14.  
Figure 14 Power supply installed in mounting bracket cradle on the ET0010A  
4
Connect the power supply cable to the rear panel connector.  
Figure 15 shows the ET0010A power connector.  
30  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the ET0010A  
Figure 15 Insert the power supply cable into the connector on the rear panel  
5
Attach the mounting brackets to the rack’s front supports with the large #10-32 screws (item 1 in  
Figure 11), using a #2 Phillips screwdriver. Insert two screws in each bracket, using the top and  
bottom holes.  
Figure 16 Front view of ET0010A mounting brackets and power supply  
Solid Surface Installation  
When installing the ET0010A on a solid surface, have the following tools and materials available to  
attach the rubber feet to the bottom of the unit:  
External power supply  
(4) rubber feet, supplied in the Accessory Kit (item 3 in Figure 11).  
(4) small silver screws with built-in washers, supplied in the Accessory Kit (item 4 in Figure 11).  
#1 Phillips screwdriver (user-supplied)  
To install the ETEP on a solid surface:  
1
2
Place the unit on a solid surface, with the bottom panel facing up.  
Locate the four screw holes on the bottom of the unit (Figure 17).  
ETEP Installation Guide  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
Figure 17 Screw holes for rubber feet installation on bottom of unit  
3
Place one of the rubber feet over the hole and insert a screw into the opening (Figure 18). Tighten the  
screw.  
Figure 18 Rubber feet installed  
4
5
6
Repeat step 3 for the remaining feet.  
Turn the unit over so that it is resting on the rubber feet.  
Attach the external power supply to the power connector on the rear panel.  
Figure 19 shows the ET0010A rear panel and power supply.  
32  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installing the ET0010A  
Figure 19 ET0010A rear panel connector for external power supply.  
Connecting the Cables: ET0010A  
Follow the instructions below to connect the ET0010A to the appropriate network devices (see Figure  
20).  
To cable the ET0010A:  
1
For initial setup, connect the RS-232 serial port directly to a PC or workstation. Using the null  
modem cable supplied by Black Box, insert the RJ-45 connector in the RS-232 port and connect the  
DB-9 female connector to your PC. This cable can be removed after initial setup is complete.  
2
3
Connect the Ethernet management port to a LAN using a Category 5 cable with an RJ-45 connector.  
Connect the remote port to the untrusted network, typically via a router port, using a Category 5 cable  
with an RJ-45 connector.  
4
Connect the local port to the local device, such as a server or switch, using a Category 5 cable with an  
RJ-45 connector.  
ETEP Installation Guide  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation  
Figure 20 ET0010A Cabling  
NOTE  
The Aux1 port on the ET0010A is not enabled in this release.  
Powering On the ET0010A  
Use the following procedure to power up the ETEP.  
Figure 21 Attaching the power cables on the ET0010A  
34  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installing the ET0100A  
To power on the ETEP:  
1
Check that the power supply cable is properly inserted in the power connector on the ETEP rear  
panel. The ET0010A is shown in Figure 21.  
2
Plug the power cord into the ETEP power supply. Attach the opposite end to a power source to apply  
power to the appliance.  
When the appliance powers up, all LEDs illuminate. The power LED remains lit until the unit is powered  
off.  
During the boot process the ETEP cycles through its startup tests, and the corresponding status LEDs are  
illuminated (see “Status Codes: ET0010A” on page 63). After the tests execute successfully, the status  
indicators turn off.  
NOTE  
During the boot process the ETEP discards all traffic on its data ports. Once the appliance is operational,  
the default mode of operation passes all packets in the clear until you deploy security policies.  
Installing the ET0100A  
To prepare the ET0100A for installation, review the installation steps in Table 13, unpack the shipping  
carton, and prepare a space for the installation of the appliance.  
The steps to perform for a typical installation are listed below.  
Table 13  
ET0100A Installation Steps  
Step  
Action to Perform  
Description  
1
2
3
4
5
Review the cabling requirements.  
Unpack the shipping package.  
Prepare a space for installation of the ET0100A.  
Connect the cables.  
Apply power to the ET0100A.  
Cabling Requirements: ET0100A  
Table 14 outlines the standard cables used with each port on the ET0100A. The connector type listed  
indicates only what is required to connect to the ET0100A port, and may or may not be the same  
ETEP Installation Guide  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
connector type required for the other end of the cable. Some cables are supplied by Black Box and others  
are user-supplied.  
Table 14 ET0100A Standard Cables  
ET0100A Port  
Cabling  
Supplied by...  
Power receptacle  
Power supply cable certified  
and approved for use in the  
country of interest  
Black Box  
RS-232 Port  
Shielded copper null modem  
cable, RS-232 DB9 connector  
(female to male)  
Black Box  
Black Box  
User  
10/100 Ethernet Management  
Port  
Shielded Category 5 straight  
through cable (STP), RJ-45  
a
connector  
Remote and Local ports  
Shielded Category 5 straight  
through cables (STP), RJ-45  
connector  
a. The local, remote, and Ethernet management ports are auto-sensing for polarity. You can use shielded Category 5  
straight through cables or crossover cables when connecting to these ports.  
NOTE  
To meet the requirements of FCC Part 15 and the EU EMC Directive 2004/108/EC, use only shielded  
cables with the ET0100A (DB-9 null modem cables and Category 5 STP cables).  
Unpacking the Shipping Carton: ET0100A  
Remove all product components from the shipping carton and compare the contents to the packing list.  
Keep all packaging in case it is necessary to return the unit.  
The ET0100A is packaged with the standard items listed below. Additional cables, country-specific power  
cords, and other accessories can be ordered separately.  
1
2
ET0100A chassis  
Firmware and software is factory-installed on the unit.  
Accessory Kit  
Rack mount kit containing two mounting brackets and 10 screws  
(1) Power cable (US)  
(1) Shielded DB-9 null modem cable (female to male)  
(1) Shielded Category 5 straight through cable (STP) with RJ-45 connector  
CD containing user documentation and a backup copy of the ETEP software  
Rack-Mount Installation: ET0100A  
The ET0100A can be mounted in a standard 19-inch rack using the mounting kit, or simply placed on a  
rack shelf or solid surface. Before installing the ET0100A in a 19-inch rack, review the rack-mounting  
36  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installing the ET0100A  
To mount the ETEP in a standard 19-inch equipment rack, have the following tools and materials  
available:  
Two mounting brackets, supplied in the Accessory Kit  
(6) small screws and (4) large screws, supplied in the Accessory Kit  
#1 Phillips and #2 Phillips screwdrivers (user-supplied)  
To install the ETEP in a rack:  
1
Attach a mounting bracket to each side of the ETEP (near the front panel). Attach each bracket with  
three small screws provided in the Accessory Kit, using a #1 Phillips screwdriver.  
2
Attach the ETEP to the rack’s front supports with the large screws, using a #2 Phillips screwdriver  
(Figure 22). Insert two screws in each bracket, using the top and bottom holes.  
Figure 22 Rack Mounted ETEP, Front Panel View  
Connecting the Cables: ET0100A  
The procedure in this section describes how to connect the ET0100A to your network devices, as shown  
in Figure 23.  
To cable the ET0100A:  
1
2
3
4
For initial setup, connect the RS-232 port directly to a PC or workstation using a DB-9 null modem  
cable. This cable can be removed after initial setup is complete.  
Connect the 10/100 Ethernet management port to a LAN using a Category 5 shielded twisted pair  
(STP) cable with an RJ-45 connector.  
Connect the remote port to the untrusted network, typically via a router port, using a Category 5 STP  
cable with an RJ-45 connector.  
Connect the local port to the local device, such as a server or switch, using a Category 5 STP cable  
with an RJ-45 connector.  
ETEP Installation Guide  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installation  
Figure 23 ET0100A Cabling  
Powering on the ET0100A  
Use the following procedure to power up the ET0100A.  
To power on the ET0100A:  
On the appliance’s rear panel, plug the power cord into the ET0100A power receptacle. Attach the  
opposite end to a power source to apply power to the appliance.  
Due to the shielding in the power cable, you must exert significant pressure to properly insert the power  
cord into the ET0100A power receptacle. A properly seated power cord cannot be moved within the  
receptacle (Figure 24). Wiggling or jostling an improperly seated power cord may cause the appliance to  
reboot (Figure 25).  
Figure 24 Properly seated ET0100A power cable  
38  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installing the ET1000A  
Figure 25 Improperly seated ET0100A power cable  
When the appliance powers up, all LEDs illuminate (see Figure 26). The Alarm LED illuminates briefly  
and the diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning.  
The power LED remains lit until the unit is powered off.  
During the boot process the ET0100A cycles through its startup tests, and the corresponding diagnostic  
codes are displayed (see “Diagnostic Codes: ET0100A and ET1000A” on page 64). After the tests  
execute successfully, the diagnostic code display is solidly illuminated with code 00.  
NOTE  
During the boot process the ET0100A discards all traffic on its data ports. Once the appliance is  
operational, the default mode of operation passes all packets in the clear until you deploy security policies.  
Figure 26 ET0100A Front Panel Status Indicators  
Elements of Figure 26:  
1)  
2)  
3)  
Diagnostic display  
Alarm LED  
Power indicator  
Installing the ET1000A  
To prepare the ET1000A for installation, review the installation steps in Table 15, unpack the shipping  
carton, and prepare a space for the installation of the appliance.  
ETEP Installation Guide  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
The steps to perform for a typical installation are listed below.  
Table 15  
ET1000A Installation Steps  
Step  
Action to Perform  
Description  
1
1
2
3
4
Review the cabling requirements.  
Unpack the shipping package.  
Prepare a space for installation of the ET1000A.  
Connect the cables.  
Apply power to the ET1000A.  
Cabling Requirements: ET1000A  
Table 16 outlines the standard cables used with each port on the ET1000A. The connector type listed  
indicates only what is required to connect to the ET1000A port, and may or may not be the same  
connector type required for the other end of the cable. Some cables are supplied by Black Box and others  
are user-supplied.  
Table 16  
ET1000A Port  
Power receptacles  
ET1000A Standard Cables  
Cabling  
Supplied by...  
Power supply cables certified  
and approved for use in the  
country of interest  
Black Box  
RS-232 Port  
Shielded copper null modem  
cable, RS-232 DB9 connector  
(female to male)  
Black Box  
Black Box  
Ethernet Management Port  
(RJ-45)  
Shielded Category 5 straight  
through cable (STP), RJ-45  
a
connector  
Ethernet Management port  
(SFP)  
Not applicable. Port is not  
enabled in this release.  
Not applicable  
Local and Remote Gigabit  
Ethernet ports  
1000Base-LX SFPs  
Available as accessory options  
9/125μm single-mode duplex  
fiber or simplex fiber pair (1  
transmit, 1 receive), 1310 nm  
nominal wavelength, LC  
connector  
Optical SFP transceivers  
OR  
1000Base-SX SFPs  
62.5/125μm multi-mode  
duplex fiber or simplex fiber  
pair (1 transmit, 1 receive),  
850nm nominal wavelength,  
LC connector  
Local and Remote Gigabit  
Ethernet ports  
Shielded Category 5 straight  
through cable (STP), RJ-45  
connector  
Available as accessory options  
Not applicable  
Copper SFP transceivers  
Aux1 port (SFP)  
Not applicable. Port is not  
enabled in this release.  
a. The 10/100 Ethernet management port is auto-sensing for polarity. You can use a shielded Category 5 straight  
through cable or a shielded crossover cable when connecting to this port.  
40  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installing the ET1000A  
NOTE  
To meet the requirements of FCC Part 15 and the EU EMC Directive 2004/108/EC, use only shielded  
Category 5 cables with the ET1000A Ethernet management port.  
Unpacking the Shipping Carton: ET1000A  
Remove all product components from the shipping carton and compare the contents to the packing list.  
Keep all packaging in case it is necessary to return the unit.  
The ET1000A is packaged with the standard items listed below. Additional cables, country-specific power  
cords, SFPs, and other accessories can be ordered separately. A list of approved transceivers is included  
in the ETEP Release Note.  
1
2
ET1000A chassis  
Firmware and software is factory-installed on the unit.  
Accessory Kit  
Rack mount kit includes 2 mounting brackets, 4 large screws (#10-32), and 8 small black screws  
(2) Power cables (US)  
(1) 6 ft. shielded DB-9 null modem cable (female to male)  
(1) 6 ft. shielded Category 5 straight through cable (STP) with RJ-45 connector  
CD containing user documentation and a backup copy of the ETEP software  
Rack Mount Installation: ET1000A  
The ET1000A can be mounted in a standard 19-inch rack using the mounting kit, or simply placed on a  
rack shelf or solid surface. Before installing the ET1000A in a 19-inch rack, review the rack-mounting  
To mount the ET1000A in a standard 19-inch equipment rack, have the following tools and materials  
available:  
Two mounting brackets, supplied in the Accessory Kit  
8 small black screws and (4) large #10-32 screws, supplied in the Accessory Kit  
#1 Phillips and #2 Phillips screwdrivers (user-supplied)  
CAUTION  
In order to safely and securely and install the ET1000A in a rack, you must use the mounting brackets  
supplied in the Accessory Kit. Other brackets may fail to properly support the weight of the ET1000A.  
ETEP Installation Guide  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Installation  
To install the ET1000A in a rack:  
1
Place the unit on a solid surface, with the top facing up. Position the mounting brackets on each side  
of the appliance, as shown in Figure 27.  
Figure 27 Mounting bracket orientation  
2
Attach the mounting brackets to each side of the unit using the 8 small black screws provided in the  
accessory kit, and a #1 Phillips screwdriver, as shown in Figure 28.  
Figure 28 Each bracket is attached to the side of the ET1000A using four screws  
3
Attach the mounting brackets to the rack’s front support with the large #10-32 screws, using a #2  
Phillips screwdriver. Insert two screws in each bracket, using the top and bottom holes (Figure 29).  
Figure 29 Front view of mounting brackets  
Connecting the Cables: ET1000A  
Follow the instructions below to connect the ET1000A to the appropriate network devices (see Figure  
30).  
42  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Installing the ET1000A  
To cable the ET1000A:  
1
2
3
For initial setup, connect the RS-232 port directly to a PC or workstation using a DB-9 null modem  
cable. This cable can be removed after initial setup is complete.  
Connect the Ethernet management port to a LAN using a Category 5 shielded twisted pair (STP)  
cable with an RJ-45 connector.  
Plug an SFP Gigabit transceiver into the ET1000A remote port. If you are using an optical SFP, insert  
the fiber cable in the SFP and connect the other end to the untrusted network, typically via a router  
port. If you are using a copper SFP, use a shielded Category 5 straight through cable.  
4
Plug a second SFP Gigabit transceiver into the ET1000A local port. If you are using an optical SFP,  
insert the fiber cable in the SFP and connect the other end to the local device, such as a server or  
switch. If you are using a copper SFP, use a shielded Category 5 straight through cable.  
Figure 30 ET1000A Cabling  
NOTE  
The Gigabit management and Aux1 ports are not enabled in this release.  
Powering on the ET1000A  
Review the following guidelines prior to powering up the ET1000A:  
The ET1000A has two power supplies. We recommend that you connect the power cords to separate  
live circuits to provide redundancy in the case of a power outage on one of the circuits.  
When manually cycling the power, remove power on both circuits, wait five seconds, and then  
reapply power on both circuits.  
ETEP Installation Guide  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Installation  
Figure 31 Dual power supplies on the ET1000A rear panel  
Elements of Figure 31:  
1)  
2)  
3)  
4)  
5)  
Power cord clips  
Status LED for power supply 2  
Power receptacle for power supply 2  
Power receptacle for power supply 1  
Status LED for power supply 1  
To power on the ET1000A:  
1
2
On the appliance’s rear panel, plug the power cords into the power receptacles for each power supply.  
Attach the opposite end of the first power cord to a power source. Attach the second power cord to a  
a power source on a different circuit. The power supply status LED illuminates when power is  
applied.  
3
After the power cords are plugged in, secure the cords using the clips on the rear of the unit.  
Figure 32 The power cord for power supply # 1 is secured with a clip  
44  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Shutting Down the ETEP  
When the appliance powers up, all of the front panel LEDs illuminate (see Figure 33). The Alarm LED  
illuminates briefly and the diagnostic code LED displays 88 to verify that the diagnostic display segments  
are functioning. The power LED remains lit until the unit is powered off. The Power Supply LEDs  
illuminate for each operational power supply.  
During the boot process the ET1000A cycles through its startup tests, and the corresponding diagnostic  
codes are displayed (see “Diagnostic Codes: ET0100A and ET1000A” on page 64). After the tests  
execute successfully, the diagnostic code display is solidly illuminated with code 00.  
NOTE  
During the boot process the ET1000A discards all traffic on its data ports. Once the appliance is  
operational, the default mode of operation passes all packets in the clear until you deploy security policies.  
Figure 33 ET1000A Front Panel Status Indicators  
Elements of Figure 33:  
1)  
2)  
3)  
4)  
Alarm LED  
Diagnostic display  
Power indicator  
Power supply LEDs  
Shutting Down the ETEP  
It is important that a proper system shutdown is performed prior to powering off the appliance. The  
shutdown command halts all running tasks on the ETEP and prepares it for being powered off. Failure to  
perform a shutdown may lead to file system corruption and potential appliance failure.  
The ETEP remains in a shutdown state until the power is cycled. The shutdown state is indicated with an  
operational code on the status/diagnostic display as shown in Table 17.  
Table 17  
Appliance model  
ET0010A  
ET0100A, CEP100-XSA, CEP1000, ET1000A  
Shutdown operational codes  
Operational code  
2, 3, 4  
– –  
ETEP Installation Guide  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installation  
You can perform a shutdown using a CLI command or ETEMS. The following procedure describes the  
CLI command.  
To shut down the ETEP from the CLI:  
1
2
Log in as Administrator (user name admin) or Ops (user name ops).  
At the command prompt, type shutdown. After the system shutdown is complete, the following  
message is displayed on the terminal.  
Power cycle required to reboot appliance  
3
Unplug the power cable from the back of the unit or from the power outlet.  
Example  
In the following example the user logs in as admin and shuts down the ETEP.  
pep login: admin  
Password:  
Last login: Tue Apr 8 15:12:21 2008 on ttyS0  
Welcome admin it is Tue Apr 8 15:17:57 UTC 2008  
admin> shutdown  
Related topic:  
“shutdown” on page 148  
46  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3 Initial Setup  
This section includes the following topics:  
Overview  
The following steps are required for initial setup of the ETEP:  
1
2
3
4
Log in through a serial link.  
Configure the management port.  
Set the date and time.  
Enter the throughput license.  
Logging In Through a Serial Link  
Initial setup is performed through a serial link to the RS-232 port. The initial setup commands are  
available to the Admin and Ops users. The procedures and examples in this chapter assume that the  
Admin user is performing the setup tasks.  
ETEP Installation Guide  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Initial Setup  
To log in to the CLI via a serial link:  
1
2
Connect the RS-232 serial port directly to a PC or workstation, as described in Chapter 2.  
Open a terminal session through a VT-100 terminal emulation program such as HyperTerminal. Enter  
the connection name, the appropriate serial port (usually COM1 or COM2), and the following serial  
port parameters:  
Baud Speed  
Parity  
38,400  
None  
8
Data Bits  
Stop Bits  
1
Flow Control  
None  
3
4
In the terminal session window, press ENTER. The login prompt displays.  
Linux 2.6.16.17 on mips  
pep login:  
At the login prompt, type the default user name admin and press ENTER. User names and  
passwords are case-sensitive.  
5
6
At the password prompt, type the default password admin and press ENTER.  
When you are successfully logged in, the command line prompt displays as shown below (password  
text is not displayed).  
pep login: admin  
Password:  
Last login: Tue Jan 29 19:18:59 2008 on ttyS0  
Welcome admin it is Tue Jan 29 19:37:12 UTC 2008  
admin>  
It is strongly recommended that you change the default passwords when you configure the ETEP for  
operation. For more information about user management see the documentation for your management  
software: ETEP CLI User Guide or the EncrypTight User Guide.  
Configuring the Management Port  
The ETEP can be managed in-line or out-of-band through a dedicated Ethernet management interface.  
Management port configuration consists of the following items:  
Setting the IP address and default gateway  
Reviewing the auto-negotiation settings  
About the management port IP address, mask and gateway  
The management port must have an assigned IP address in order to be managed remotely and  
communicate with other devices. An IPv4 IP address is mandatory, even when the ETEP is operating in  
an IPv6 network. When the ETEP is operating in an IPv6 network, configure the ETEP for dual-homed  
operation by assigning an IPv4 and an IPv6 address to the management port.  
48  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Configuring the Management Port  
The Ethernet management port IP address identifies the ETEP to the management workstation. The  
subnet mask is the portion of the IP address that identifies the network or subnetwork for routing  
purposes.  
When the ETEP management port and the management workstation are on different subnets, the ETEP  
uses a default gateway to route packets to the other devices. The default gateway identifies the local  
router port that is on the same subnet as the ETEP Ethernet management port. The appliance sends all  
packets to the specified router for forwarding to the management station or other EncrypTight  
components (key generation server, time server). When the management port and workstation are on the  
same subnet a default gateway is not needed to route packets between the devices.  
Figure 34 shows an example of a default gateway when the management station and ETEP are on  
different subnets. The management station’s IP address is 192.168.1.10, and the ETEP’s management port  
IP address is 192.168.10.10. To send packets between the two devices, the local port on Router #1 is  
specified as the default gateway (192.168.10.1). The gateway address must match the subnet of the  
management port.  
Figure 34 Management Port Default Gateway  
About auto-negotiation  
The default setting for the ETEP enables auto-negotiation, which negotiates the link speed, duplex setting,  
and flow control. Use the autoneg command if the device that the ETEP connects to from a particular  
port does not support auto-negotiation or flow control.  
It is important to configure the ETEP and the other device the same way. Both devices should either auto-  
negotiate or be set manually to the same speed and duplex mode. Having one device set manually and the  
other auto-negotiate can cause problems that make the link perform slowly. When manually setting the  
ETEP link speed, configure the speed and duplex mode to match that of the other device.  
On the management port, the ETEPs can negotiate to the following link speeds:  
Table 18  
Link speeds on the management port  
Auto-negotiate  
ET0010A  
Auto-negotiate  
Fixed Speed  
All ETEPs  
Link speed  
ET0100A, ET1000A  
10 Mbps Half-duplex  
10 Mbps Full-duplex  
100 Mbps Half-duplex  
100 Mbps Full-duplex  
3
3
3
3
3
3
3
3
3
3
3
3
ETEP Installation Guide  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initial Setup  
Table 18  
Link speeds on the management port  
Auto-negotiate  
ET0010A  
Auto-negotiate  
ET0100A, ET1000A  
Fixed Speed  
All ETEPs  
Link speed  
1000 Mbps Full-duplex  
1000 Mbps Half-duplex  
3
3
To configure the management port:  
1
2
3
At the command prompt, type configureto enter configuration mode.  
At the config>prompt, type management-interface.  
Assigning an IPv4 address to the management port is mandatory. To set the management port IPv4  
address, mask, and gateway, type  
ip <ip address> <subnet mask> [gateway]  
ip address  
subnet mask  
gateway  
Management port IP address, entered in dotted decimal notation.  
IP subnet mask, entered in dotted decimal notation.  
Specifies how to route traffic between the ETEP management port and the  
management station. When the management port is on a different subnet than  
the management station, specify the IP address of the router’s local port on  
the same subnet as the ETEP management port (see Figure 34). If the  
devices are on the same subnet, you do not need to enter a default gateway.  
After entering the new IP address, it takes 10-20 seconds for the ETEP to set the address on the  
management port. During that time you cannot enter any CLI commands. When the operation is  
complete, the man-if>prompt is displayed.  
4
Optional. If the ETEP is operating in an IPv6 network you can also assign an IPv6 address to the  
management port. To do so, type  
ip6 {<ip address>/<prefix-length>} [gateway]  
ip address  
IPv6 address of the ETEP management port. This is a 128-bit address  
consisting of eight hexadecimal groups that are separated by colons. Each  
group is a 4-digit hexadecimal number. The hexadecimal letters in IPv6  
addresses are not case sensitive.  
prefix-length  
gateway  
A decimal value that indicates the number of contiguous, higher-order bits of  
the address that make up the network portion of the address. The decimal  
value is preceded by a forward slash (/).  
IPv6 address of the router port that is on the same local network as the ETEP  
management port.  
5
6
Auto-negotiation is enabled by default. If you want to disable auto-negotiation and manually set the  
link speed and flow control, configure the autoneg command. Attributes are described in Table 19.  
autoneg {enable} | {disable [<speed>] [<flow-control>]}  
Type exitto return to the config prompt, or type top to return to the command prompt.  
50  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setting the Date and Time  
Table 19  
Management port autoneg command description  
Description  
Attribute  
enable  
Enables auto-negotiation on the management port. This is the default  
setting.  
disable  
speed  
Disables auto-negotiation on the management port. Use this setting to  
manually configure link speed and flow control.  
[100m-full | 10m-full | 100m-half | 10m-half]  
When auto-negotiation is disabled, the speed attribute specifies the link  
speed and duplex setting. The speed defaults to 100m-full.  
flow control  
[on | off]  
When auto-negotiation is disabled, this attribute configures the flow control  
setting to be on or off. The flow control setting defaults to on.  
Example  
The following example sets the management port IPv4 address, subnet mask, and gateway for the  
ETEP as shown in Figure 34. Auto-negotiation is left at its default setting of enabled.  
admin> configure  
config> management-interface  
man-if> ip 192.168.10.10 255.255.255.0 192.168.10.1  
man-if> exit  
The next example sets the management IPv4 address and subnet mask, and omits the default gateway.  
The default gateway can be omitted when the management station and the ETEP management port  
and are wired directly to each other on the same subnet. Auto-negotiation is disabled. The link speed  
is set to 100 Mbps full-duplex and flow control is turned on.  
admin> configure  
config> management-interface  
man-if> ip 192.168.10.10 255.255.255.255  
man-if> autoneg disable 100m-full on  
man-if> exit  
The following example sets an IPv6 address, prefix length, and default gateway on the management  
port.  
admin> configure  
config> management-interface  
man-if> ip6 2001:DB8::211:11FF:FE58:743/642001:DB8::20F:F7FF:FE84:BFC2  
man-if> exit  
config>  
Setting the Date and Time  
Setting the date and time on the ETEP helps ensure that the appliance’s time can be synchronized  
properly with other ETEPs or components in the EncrypTight system.  
The time zone on the ETEP is set to UTC 0 (Coordinated Universal Time), and is not user configurable.  
Enter the date and time relative to UTC 0, also referred to as Greenwich Mean Time (GMT). To calculate  
ETEP Installation Guide  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Initial Setup  
the local time relative to UTC, add or subtract the offset hours from UTC for the local time zone (UTC ±  
n). The following examples give the local time at various locations at 12:00 UTC when daylight saving  
time is not in effect:  
New York City, United States: UTC-5; 07:00  
New Delhi, India: UTC+5:30; 17:30  
To set the date and time:  
1
2
At the command prompt, type configureto enter configuration mode.  
At the config>prompt, type date <year> <month> <day> <hour> <minutes>  
<seconds>  
year  
2008-2037  
01-12  
month  
day  
01-31  
hour  
00-23  
minutes  
seconds  
00-59  
00-59  
3
Type exitto return to the command prompt.  
Example  
admin> configure  
config> date 2008 10 11 15 30 00  
config> exit  
Entering a Throughput License  
The method for entering licenses on the ETEP depends on your management software:  
For ETEPs that are managed exclusively through the command line, follow the procedure in this  
section.  
For EncrypTight deployments, throughput licenses must be managed with the EncrypTight software.  
Licenses entered from the CLI are not recognized as valid in an EncrypTight deployment. See the  
EncrypTight User Guide for more information.  
Each ETEP is capable of transmitting traffic at a range of speeds that varies by model. When you install  
the license you purchased, ETEPs transmit traffic at the speed specified by the license.Table 20 lists the  
available speeds for each ETEP model.  
Table 20  
ETEP Throughput Speeds  
Available Throughput  
Model  
ET0010A  
ET0100A  
ET1000A  
3, 6, 10, 25, 50 Mbps  
100, 155, 250 Mbps  
500, 650 Mbps, 1 Gbps  
52  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Configuration Example  
You need to install a license on each ETEP that you use. Licenses are linked to the serial number of the  
ETEP on which they are installed. You cannot install a license intended for one ETEP on a different  
ETEP.  
If you upgrade from a command line-only installation to a full EncrypTight deployment, you can no  
longer use the command line-only license and must acquire an EncrypTight license.  
To add a license from the command line:  
1
2
At the command prompt, type configureto enter configuration mode.  
At the config>prompt, type license <string>, where string is the license provided by  
Customer Support. The license is case sensitive. Enter the license exactly as provided. It will look  
something like this: 1:0:0508C482:10:258482fab2  
To view the ETEP throughput speed:  
At the command prompt, type show throughput-speed.  
1
Configuration Example  
The following example illustrates the commands used for initial setup of the ETEP to configure the  
following parameters: management IP address, subnet mask, and default gateway, auto-negotiation, date  
and time. The autoneg command needs to be configured only if you want to disable auto-negotiation and  
configure the link speed and flow control manually.  
pep login: admin  
Password: *****  
admin> configure  
config> management-interface  
man-if> ip 192.168.10.10 255.255.255.0 192.168.10.1  
man-if> autoneg disable 100m-full on  
man-if> exit  
config> date 2008 10 15 12 30 00  
config> exit  
admin>  
Managing the ETEP  
The ETEP can be managed in two ways, depending on the size and complexity of your deployment:  
Command Line Interface (CLI)  
You can configure the ETEPs for operation and create Layer 2 point-to-point policies using the CLI  
commands.  
To manage the ETEP using the CLI, you can attached a PC directly to the serial port or use any SSH  
client for a secure remote connection through the Ethernet management port.  
EncrypTight Policy and Key Manager™  
EncrypTight can distribute keys to a large number of ETEPs. It works for complex mesh, hub and  
spoke, and multicast networks, as well as in straightforward point-to-point topologies. EncrypTight  
ETEP Installation Guide  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Initial Setup  
includes tools for appliance configuration, policy definition and deployment, and key generation and  
distribution.  
To prepare the ETEP for operation in the network, you will need to perform the following tasks:  
1
2
3
Assign passwords  
Configure the ETEP  
Define security policies  
If you plan to operate the ETEP in FIPS mode, we recommend enabling FIPS mode as your first  
configuration task. Entering FIPS mode resets many configuration items, such as passwords, policies, and  
certificates. To avoid having to reconfigure the ETEP, enable FIPS mode and then perform the rest of the  
appliance and policy configuration tasks.  
See the user guide for your management software for details:  
ETEP CLI User Guide  
EncrypTight User Guide  
54  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
4 Maintenance  
This section includes the following topics:  
Preventative Maintenance  
Periodically perform maintenance on your ETEP. Keep components free of dust and other particulate  
matter. Examine cables for damage and ensure that airflow requirements have been met. On ETEP  
models that have fans, check the fans for reduced airflow caused by dust build-up and clean as necessary.  
No special maintenance is required.  
The ETEP is housed in a tamper evident chassis. Periodically check the chassis for evidence of  
tampering. Items to look for include stripped screws and damage to the tamper-evident seal. The tamper-  
evident seal is located on the rear panel;  
The frequency of a physical inspection depends on the value of the intellectual property being protected  
and the security of the environment in which the ETEP is located. For example, a locked equipment  
closet is more secure than an open server room. At a minimum, it is recommended that the unit’s physical  
integrity be checked on a monthly basis.  
CAUTION  
The ETEP does not contain any field-replaceable internal parts. Do not remove the unit’s cover for any  
reason. Removing the cover will zeroize the ETEP, returning it to its factory default state. All configuration  
data and keys are destroyed during the zeroization process. The cover is to be removed only by  
authorized service personnel. Unauthorized cover removal voids the product warranty.  
CAUTION  
Disconnect all power cords before servicing.  
ETEP Installation Guide  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Maintenance  
What To Do If an Appliance Fails  
Most ETEP models do not contain any field-replaceable parts. If you experience an appliance failure,  
contact Customer Support for a replacement ETEP and throughput license.  
The ET1000A has field-replaceable power supplies. Contact Customer Support to obtain a replacement  
power supply in the event of a failure. See “Replacing the ET1000A Power Supply” on page 56 for  
removal and installation instructions.  
Related topics:  
Obtaining a License for Replacement Units  
When replacing an ETEP with a spare, the replacement ETEP will run at full throughput for a grace  
period. During the grace period, contact customer support to report the RMA unit and to receive a new  
license for the replacement. Licenses are linked to the serial number of the ETEP on which they are  
installed. You cannot install a license intended for one ETEP on a different ETEP.  
Upon receipt of the new license, install it on the ETEP as described in “Entering a Throughput License”  
Replacing the ET1000A Power Supply  
The ET1000A comes with dual internal power supplies. In the event of a failure, each power supply can  
be removed and replaced in the field.  
CAUTION  
Disconnect all power cords before servicing the ET1000A.  
To replace a power supply in the ET1000A:  
1
2
Unplug both power supplies at the power source.  
On the rear panel, lift the power cord clip on the affected power supply, and then remove the power  
cord from the receptacle (Figure 35).  
56  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
What To Do If an Appliance Fails  
Figure 35 Power cord is removed from power supply # 2  
3
Locate the release lever on the left of the power supply (Figure 36). Press the release lever inward  
toward the metal support to release the power supply latch. Pull the power supply outward to remove  
it from the chassis.  
Figure 36 Release lever on power supply # 2  
4
On the replacement power supply, press the release lever toward the metal support and insert the new  
power supply until it latches (Figure 37). When the power supply is correctly inserted, you should not  
be able to remove it by pulling on it. It can only be removed when the latch is disengaged.  
ETEP Installation Guide  
57  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
Figure 37 Slide the replacement power supply into the slot on the rear panel  
5
6
7
Insert the power cord in the replacement power supply and secure it with the clip.  
Reconnect power supplies 1 and 2 to their respective power sources.  
Return the failed power supply to Black Box as directed by Customer Support.  
Tamper Switch and Zeroization  
The following ETEP models include a tamper switch: ET0010A, ET0100A, and ET1000A. The switch is  
activated if the ETEP cover is removed while the unit is operating or if the ETEP detects that the cover is  
open while it is booting. When the ETEP detects that the switch is activated it enters an error state,  
zeroizes the appliance’s keying material, and discards all traffic. Zeroization has the same effect as  
issuing the filesystem-reset command.  
Zeroization occurs under the following conditions:  
When operating in FIPS mode, the FIPS self-tests fail during boot  
When operating in FIPS mode, signature errors are detected on critical files pertaining to policies and  
keys  
The tamper switch is activated when the cover is removed  
The following events occur when the ETEP is zeroized:  
Alarm LED illuminates  
The ETEP sends a critical error trap  
The ETEP discards all packets that it receives on the local and remote ports  
Ethernet management port communication is disabled. You will be unable to manage the ETEP using  
ETEMS.  
CLI login is disabled via the serial port and Ssh  
Data files are permanently deleted, including log files  
The file system is reset to factory defaults  
The zeroization process takes about 20 minutes to complete.  
58  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Cable Pinouts  
To recover the ETEP following zeroization:  
Wait approximately 20 minutes for the zeroization process to complete. If you are connected to the ETEP  
through the serial port, you will see the following message:  
Power cycle required to reboot appliance  
After cycling the power, you will be able to configure and manage the ETEP from its factory default  
settings. If you cycle the power prior to the completion of the zeroization process the appliance will enter  
an unrecoverable state, which requires returning the ETEP to the factory.  
Related topic:  
“filesystem-reset” on page 132  
Cable Pinouts  
This section lists the serial cable pinouts for the following ETEPs:  
ET0010A  
ET0100A/ET1000A  
RS-232 Serial Cable: ET0010A  
The RS-232 serial cable on the ET0010A is a null modem cable with an RJ-45 connector to the  
ET0010A and a DB-9 female connector to a PC or laptop.  
Figure 38 ET0010A Null Modem Serial Cable  
Table 21  
RJ-45 Pin  
ET0010A Null Modem Pin Connection  
DB-9 Pin  
3 Receive Data  
6 Transmit Data  
5 Signal Ground  
3 Transmit Data  
2 Receive Data  
5 Signal Ground  
ETEP Installation Guide  
59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Maintenance  
RS-232 Serial Cable: ET0100A/ET1000A  
The RS-232 serial cable on the ET0100A and ET1000A is a null modem cable with DB-9 connectors  
(female to male).  
Figure 39 ET0100A/ET1000A Null Modem Serial Cable  
Table 22  
Pin  
ET0100A/ET1000A Null Modem Pin Connection  
Pin  
2 Receive Data  
3 Transmit Data  
5 Signal Ground  
3 Transmit Data  
2 Receive Data  
5 Signal Ground  
60  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5 Troubleshooting  
This section includes the following topics:  
Symptoms and Solutions  
The following tables provide some solutions to common problems that may occur with your ETEP.  
LED Indicators  
Table 23  
Symptom  
LED Indicators  
Explanation and Possible Solution  
No power light.  
Make sure the power cable is attached and plugged in to both  
the device and the power outlet.  
Alarm light is lit.  
The ETEP is in an error state. See “Error State” on page 62 for  
information about possible causes and recovery procedures.  
Port status LED is off (no link).  
Check the network cable. Verify correct transmit and receive  
cable polarity.  
Check the operational status of the equipment being connected.  
Verify that the auto-negotiation and flow control settings on the  
local or remote port in question match the settings of the  
equipment to which they are connected.  
If the problem is not resolved, the network may not be  
functioning properly. Consult a local network administrator.  
Port status LED is not blinking  
(no traffic).  
Check physical connectivity.  
Verify that the policies are set up to allow traffic to pass through  
the appliance.  
Check with your Network Administrator to ensure proper  
placement in the network.  
ETEP Installation Guide  
61  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Troubleshooting  
Table 23  
Symptom  
Power supply LED is off  
LED Indicators  
Explanation and Possible Solution  
The power supply is unplugged or is unable to recover from a  
power interruption.  
Make sure the power cable is attached and plugged in to the  
power supply and the power outlet.  
Check the status LED on the power supply on the rear of the  
unit. If the LED is off, the power supply is not receiving power. If  
the LED is red, the power supply requires a manual power  
cycle. Unplug the power cord, wait 5 seconds, and then reapply  
power. The LED is green during normal operation. If a manual  
power cycle does not restore power, contact customer support.  
Error State  
Table 24  
Symptom  
Error State Symptoms and Solutions  
Explanation and Possible Solutions  
The Alarm LED is illuminated  
The ETEP enters an error state when a boot test fails, the  
operating temperature threshold is exceeded, signature errors are  
detected on critical files pertaining to policies and keys. or a FIPS  
test fails when the ETEP is in FIPS mode.  
When the ETEP is in an error state the Alarm LED illuminates, and  
the appliance discards all packets it receives. Depending on the  
error, other notifications may be sent (traps, status messages to the  
ETEMS or the terminal).  
To recover from an error state when FIPS mode is disabled:  
When the ETEP detects a corrupted policy, it enters an error  
state and sends a critical error trap to the management station.  
To recover, redeploy the policies and then reboot the ETEP.  
For non-policy errors, reboot the appliance. If the operating  
temperature threshold is exceeded, cycle the power to restart  
the ETEP.  
If a failure occurs during the boot process, refer to “Diagnostic  
Code Display” on page 63 for additional troubleshooting  
information.  
If the actions listed above do not clear the error, contact  
customer support.  
To recover from an error state when the ETEP is in FIPS mode:  
A FIPS test failure or signature error will cause the ETEP to  
zeroize. To learn more about the zeroization process and  
recovery from that state, see Tamper Switch and Zeroization”  
Temperature Threshold and Discarded Traffic  
When the ETEP enters an alarm state due to a temperature failure, the Alarm indicator illuminates and  
the ETEP discards traffic. The ETEP remains in an error state until it is rebooted. However, once the  
temperature drops below the critical threshold, the alarm indicator turns off and the ETEP stops reporting  
an alarm state to ETEMS, even though the alarm state has not been cleared and the ETEP continues to  
discard traffic.  
62  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
Diagnostic Code Display  
If the ETEP is discarding traffic, check the system log for temperature warning notices to confirm that a  
temperature error occurred. Reboot the ETEP to resume normal operation.  
Diagnostic Code Display  
ETEPs display self-test codes during boot up, in addition to operational status and error conditions. See  
the following sections for information about your appliance model:  
Status Codes: ET0010A  
The ET0010A status LEDs display self-test codes during boot up. After the ET0010A boots, the status  
LEDs reflect the operational state of the appliance.  
When the appliance powers up, the Alarm LED illuminates briefly and the four status LEDs illuminate to  
verify that they are functioning. As the ET0010A cycles through its self-tests the status LEDs indicate the  
self-test that is in progress (see Table 25). After the tests execute successfully, the status LEDs turn off.  
If the ET0010A fails to boot properly the illuminated status LEDs indicate the number of the last test that  
completed successfully, and a message describing the failure is displayed on the terminal. In addition, the  
Alarm light illuminates if any of the first four self-tests fail (status LEDs 1, 2, 1&2, or 3). In the event of  
a failure, make a note of the status code and of the error message on the console, and then contact Black  
Box customer support.  
Table 25  
ET0010A Self-Tests  
Status LEDs Illuminated  
Description  
1, 2, 3, 4  
LED display test.  
1
Bootflash CRC test.  
2
DRAM test #1.  
1, 2  
3
Initialize IO devices. DRAM test #2.  
Initialize compact flash.  
Complete bootloader initialization.  
Download operating system.  
1,3  
2,3  
1, 2, 3  
Start operating system, IPSec dataplane code, and management  
and control software.  
All status LEDs off  
Up and operational.  
After the ET0010A boots up, the status LEDs reflect the operational state of the appliance.  
.
Table 26  
Code  
ET0010A Operational Codes  
Description  
All status LEDs off  
2, 3, 4  
Up and operational.  
The ET0010A is in a shutdown state.  
ETEP Installation Guide  
63  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Troubleshooting  
Diagnostic Codes: ET0100A and ET1000A  
The 7-segment diagnostic display on the front panel of the following models displays self-test codes  
during boot up: ET0100A and ET1000A. After the ETEP boots, the display reflects the operational state  
of the appliance and error conditions.  
When the appliance powers up, all LEDs illuminate. The Alarm LED illuminates briefly and the  
diagnostic code LED displays 88 to verify that the diagnostic display segments are functioning. As the  
ETEP cycles through its self-tests the corresponding diagnostic code is displayed (see Table 27). After the  
tests execute successfully, the diagnostic code display is solidly illuminated with code 00.  
If the ETEP fails to boot properly the diagnostic code display indicates the number of the last test that  
completed successfully, and a message describing the failure is displayed on the terminal. In addition, the  
Alarm light illuminates if diagnostic tests 01-04 fail. In the event of a failure, make a note of the code  
and of the error message on the console, and then contact Black Box customer support.  
Table 27  
ET0100A/ET1000A Self-Tests  
Description  
Code  
88  
7-segment display test.  
01  
Bootflash CRC test.  
02  
DRAM test #1.  
03  
Initialize IO devices. DRAM test #2.  
Initialize compact flash.  
04  
05  
Complete bootloader initialization.  
Download operating system.  
06  
07  
Start operating system, IPSec dataplane code, and management  
and control software.  
00  
Up and operational.  
After the ETEP boots up, the diagnostic display reflects the operational state of the appliance.  
.
Table 28  
ET0100A/ET1000A Operational Codes  
Code  
00  
Description  
Up and operational.  
rb  
The ETEP is in a reboot required state.  
AL  
An alarm condition or error condition has been reported.  
The ETEP is downloading new software.  
The ETEP is in a shutdown state.  
dL  
– –  
64  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
           
Appendix A Environmental and  
Regulatory Information  
This section includes the following topics:  
WEEE Directive  
Black Box is committed to environmentally responsible behavior. As part of this commitment, we have  
put in place a product end-of-life management solution that meets the European Union’s Waste Electrical  
and Electronic Equipment (WEEE) Directive. All products shipped from the Black Box manufacturing  
facility have the appropriate WEEE markings and qualify for the recycling program. Black Box products  
that have reached the end of their useful life are to be recycled. Send all requests for recycling to Black  
Box, and we will arrange for pick up and transport to a recycling location that complies in an  
environmentally responsible manner with the EU WEEE Directive.  
RoHS Directive  
The Restriction of Hazardous Substances (RoHS) Directive restricts the use of certain materials that are  
commonly found in electronic products. Restricted substances are heavy metals, including lead, and poly-  
brominated materials.  
Black Box has eliminated or substantially reduced its usage of the prohibited materials. However, the  
RoHS Directive allows a lead-in-solder exemption for Category 3 Telecommunications Products. It is  
Black Box’s position that its network security products qualify for the lead-in-solder exemption.  
Black Box is committed to completely eliminating its use of RoHS prohibited materials as that becomes  
technically feasible. We are constantly monitoring the availability of lead-free components and the  
progress of the lead-free manufacturing processes. We pledge to continually evolve and refine our  
products and processes as viable alternatives that do not impact product reliability or performance  
become available.  
ETEP Installation Guide  
65  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
Environmental and Regulatory Information  
For more information on the status of our RoHS efforts or product-specific environmental questions,  
please e-mail us at [email protected].  
Regulatory Information  
This section contains regulatory information for the following Black Box appliances:  
ET0010A  
ET0100A  
ET1000A  
ET0010A Regulatory Information  
The ET0010A (part number 410-032-402) has received a statement of compliance for the items listed in  
the following sections:  
Application of Regulations: FCC Title 47, Part 15, Subpart B, EMC Directive 2004/108/EC  
Class of Equipment: Class A  
Safety  
UL: IEC 60950-1:2005, Second Edition; EN 60950-1:2006  
CSA-C22.2 No. 60950-1  
Immunity  
EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-  
4:2004, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000,  
IEC 61000-4-11:1994/A1:2000)  
Emissions  
FCC Part 15, Subpart B, Class A  
EN55022: 2006, Class A  
EN61000-3-2:2006, EN61000-3-3:1995/A1:2001/A2:2005  
AS/NZS CISPR 22:2006 Class A  
FCC Information (USA)  
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant  
to Part 15 of FCC rules. Operations are subject to the following conditions:  
This device may not cause harmful interference  
This device must accept any interference received, including interference that may cause undesirable  
operation.  
66  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Regulatory Information  
Interference-Causing Equipment Standard Compliance Notice (Canada)  
“The Class A digital apparatus complies with Canadian ICES-003.”  
“Cet appareil numerique de la class A est conforme a la norme NMB-003 du Canada.”  
European Notice  
Products with the CE Marking comply with both the EMC Directive (2004/108/EC) and the Low Voltage  
Directive (2006/95/EC) issued by the Commission of the European Community.  
ET0100A Regulatory Information  
The ET0100A, part number 410-032-002, has received a statement of compliance for the items listed in  
the following sections.  
Application of Regulations: FCC Title 47, Part 15, Subpart B, EMC Directive 2004/108/EC  
Class of Equipment: Class B  
Safety  
UL 60950-1  
CSA-C22.2 No. 60950-1  
Immunity  
EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-  
4:2004, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000,  
IEC 61000-4-11:1994/A1:2000)  
Emissions  
EN55022: 2006, ANSI C63.4:2006, EN61000-3-2:2006, EN61000-3-3:1995/A1:2001/A2:2005  
FCC Information (USA)  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful  
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency  
energy and, if not installed and used in accordance with the instructions, may cause harmful interference  
to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. If this equipment does cause harmful interference to radio or television reception, which can  
be determined by turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected. Consult the dealer or an experienced radio/TV technician for help.  
ETEP Installation Guide  
67  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                 
Environmental and Regulatory Information  
Interference-Causing Equipment Standard Compliance Notice (Canada)  
“The Class B digital apparatus complies with Canadian ICES-003.”  
“Cet appareil numerique de la class B est conforme a la norme NMB-003 du Canada.”  
European Notice  
Products with the CE Marking comply with both the EMC Directive (2004/108/EC) and the Low Voltage  
Directive (2006/95/EC) issued by the Commission of the European Community.  
ET0100A Cabling  
WARNING  
Use only shielded cables to connect I/O devices to this equipment. You are cautioned that changes or  
modifications not expressly approved by the party responsible for compliance could void your authority to  
operate the equipment.  
ET1000A Regulatory Information  
The ET1000A, part number 410-032-103, has received statements of compliance for the items listed in  
the following sections:  
Application of Regulations: FCC Title 47, Part 15, Subpart B (US), Canada Standard ICES-003,  
European Council Directive 2004/108/EC  
Class of Equipment: Class B  
Safety  
UL 60950-1, 2nd Edition, 2007-03-27  
CSA-C22.2 No. 60950-1-07, 2nd Edition, 2007-03  
IEC 60950-1, 2nd Edition  
EN 60950-1:2006+A11:2009  
EMI/EMC  
ANSI C63.4:2003  
FCC Title 47, Part 15 Subpart B  
Canada Standard ICES-003  
European Council Directive 2004/108/EC  
EN55022: 2006/A1:2007 Class B  
EN61000-3-2:2006, EN61000-3-3:1995/A1:2001/A2:2005  
68  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
               
Regulatory Information  
EN 55024:1998/A1:2001/A2:2003 (IEC 61000-4-2:1995/A2:2000, IEC 61000-4-3:2002, IEC 61000-4-  
4:2004, IEC 61000-4-5:1995/A1:2000, IEC 61000-4-6:1996/A1:2000, IEC 61000-4-8:1993/A1:2000,  
IEC 61000-4-11:1994/A1:2000)  
Australian Standard AS/NZS CISPR 22:2006 Class B  
FCC Information (USA)  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant  
to Part 15 of FCC rules.  
Interference-Causing Equipment Standard Compliance Notice (Canada)  
“The Class B digital apparatus complies with Canadian ICES-003.”  
“Cet appareil numerique de la class B est conforme a la norme NMB-003 du Canada.”  
European Notice  
Products with the CE Marking comply with the European Council Directive 2004/108/EC.  
Normas Oficiales Mexicanas (NOM): Electrical Safety  
Statement  
INSTRUCCIONES DE SEGURIDAD  
1
Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico  
sea operado.  
2
3
Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.  
Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser  
respetadas.  
4
5
Todas las instrucciones de operación y uso deben ser seguidas.  
El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño,  
lavabo, sótano mojado o cerca de una alberca, etc..  
6
7
8
9
El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por  
el fabricante.  
El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el  
fabricante.  
Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las  
instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.  
El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación  
del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación,  
no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.  
10 El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros  
de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.  
11 El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el  
instructivo de operación, o como se indique en el aparato.  
ETEP Installation Guide  
69  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Environmental and Regulatory Information  
12 Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea  
eliminada.  
13 Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados  
por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos  
donde salen del aparato.  
14 El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.  
15 En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.  
16 El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo  
de tiempo.  
17 Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u  
orificios de ventilación.  
18 Servicio por personal calificado deberá ser provisto cuando:  
a
b
c
El cable de poder o el contacto ha sido dañado; u  
Objectos han caído o líquido ha sido derramado dentro del aparato; o  
El aparato ha sido expuesto a la lluvia; o  
d
e
El aparato parece no operar normalmente o muestra un cambio en su desempeño; o  
El aparato ha sido tirado o su cubierta ha sido dañada.  
70  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
A
alarm LED  
diagrams  
ET0010A  
ET0100A  
B
booting the appliance  
ET1000A  
C
E
cables  
connecting the cables  
F
requirements  
failures  
front panel diagrams  
command line interface  
connectors  
I
initial setup  
D
default gateway configuration, management port,  
48  
diagnostics  
installation  
power up codes  
ETEP Installation Guide  
71  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Index  
ET0010A  
port status  
power indicator LED  
ET0100A  
power supply  
ET1000A  
powering up the appliance  
R
rack mount  
L
LEDs  
rear panel diagrams  
license  
regulatory information  
requirements  
M
maintenance  
management interface  
S
self-tests  
SFTP server  
software  
P
packing list  
pinouts  
specifications  
72  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
status LEDs  
T
throughput license  
See also license  
traffic status LED  
troubleshooting  
diagnostic code display  
power up codes  
U
unpacking the shipping carton  
W
Z
zeroization  
ETEP Installation Guide  
73  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
74  
ETEP Installation Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Black Box Tech Support: FREE! Live. 24/7.  
Tech support the  
way it should be.  
Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com.  
About Black Box  
Black Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything  
from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by  
free, live 24/7 Tech support available in 30 seconds or less.  
© Copyright 2011. All rights reserved. Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc.  
Any third-party trademarks appearing in this manual are acknowledged to be the property of their respective owners.  
ET0010A Installation Guide, version 1  
724-746-5500 | blackbox.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Blackberry Cell Phone BB9630TOUR User Manual
Blackberry Tablet PRD 38548 001 User Manual
Black Box Computer Hardware VideoPlex4 Video Wall Controller User Manual
Bosch Appliances Home Security System D7412GV3 User Manual
Boss Audio Systems DVR BR 600 User Manual
Braun Thermometer IRT4520USSM User Manual
Carrier Thermostat PTACSTAT NP HC User Manual
Chamberlain Home Security System CLLAD User Manual
Char Broil Electric Grill 10601514 User Manual
Chicago Electric Welder Model 91811 User Manual