INSTALLATIONAND OPERATION INSTRUCTIONS  
MODEL CFL-18NG-B, CFL-24NG-B,  
MODEL CFL-18LP-B, CFL-24LP-B,  
CFL-30LP-B, ST-CFL-24LP:  
LPGAS(PROPANE)  
CFL-30NG-B, ST-CFL-24NG:  
NATURALGAS  
READ THIS MANUAL BEFORE INSTALLATION AND  
LEAVE IT WITH THE APPLIANCE FOR OPERATION AND MAINTENANCE.  
WARNING: If the information in this  
manual is not followed exactly, a fire or  
explosion may result causing property  
damage, personal injury or loss of life.  
- Do not store or use gasoline or other  
flammable vapors and liquids in the  
vicinity of this or any other appliance.  
Underwriters Laboratories  
-
WHAT TO DO IF YOU SMELL GAS  
• Do not try to light any appliance.  
Listed  
• Do not touch any electrical switch; do not  
use any phone in your building.  
WARNING:  
• Immediately call your gas supplier from a  
neighbor's phone. Follow the gas  
supplier's instructions.  
Improper installation, adjustment, alter-  
ation, service or maintenance can cause  
injury or property damage. Refer to the  
owner's information manual provided with  
this appliance. For assistance or addi-  
tional information consult a qualified in-  
staller, service agency or the gas supplier.  
• If you cannot reach your gas supplier, call  
the fire department.  
-
Installation and service must be performed  
by a qualified installer, service agency or  
the gas supplier.  
Copyright 2005  
Please contact your Heat & Glo dealer with  
any questions or concerns. For the number  
of your nearest Heat & Glo dealer, please call  
888-427-3973  
Heat & Glo, a brand of Hearth & Home Technologies  
20802 Kensington Blvd., Lakeville, Mn 55044  
Printed in U.S.A.  
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,  
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,  
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174,  
D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
CFL-18-B  
Beginning Manufacturing Date: 7/98  
Ending Manufacturing Date: ______  
Service Parts  
(NG, LP) Exploded Parts Diagram  
(GN, PL) Vue éclatée des pièces  
13  
15  
11  
10  
9
12  
14  
8
2
3
16  
5
1
Part number list on following page.  
La liste des numéros de pièce se  
*
6
7
*
trouve à la page suivante.  
4
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Service Parts List / Liste des pièces de rechange  
CFL-18-B  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,  
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est  
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une  
ITEM /  
PIÈCE  
SERIAL #  
/N° DE SÉRIE  
PART NUMBER  
/ N° DE PIÈCE  
DESCRIPTION  
1
1
Valve NG / Valve GN  
Valve LP / Valve PL  
060-500  
060-501  
446-512A  
446-513A  
446-505  
446-517  
446-511  
060-512  
526-326A  
526-326A  
477-301A  
526-360  
302-320A  
060-511  
291-513  
Pilot Assembly NG / Module de veilleuse GN  
Pilot Assembly PL / Module de veilleuse PL  
Pilot Orifice NG / Orifice de veilleuse GN  
Pilot Orifice PL / Orifice de veilleuse PL  
Thermocouple / Thermocouple  
Thermopile / Thermopile  
2
2
3
4
5
6
7
Burner NG / Brûleur GN  
Burner LP / Brûleur PL  
Burner Tube / Tube de brûleur  
Grate Assembly / Grille  
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle  
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT  
Piezo Ignitor / Allumage Piézo  
SRV481-766  
SRV481-755  
8 & 9 Must order both logs / Bûches  
PRE  
4-04  
POST 4-04  
POST 4-04  
8
9
Logs 1 and 2 / Bûches 1 and 2  
Logs 3 and 4 / Bûches 3 and 4  
SRV481-766  
SRV481-755  
10 Log 5 / Bûche 5  
11 Log 6 / Bûche 6  
SRV481-701  
SRV481-705  
12 Log 7 / Bûche 7  
SRV446-702  
SRV481-703  
SRV402-701  
SRV446-706  
526-801  
13 Log 8 / Bûche 8  
14 Log 9 / Bûche 9  
15 Log 10 / Bûche 10  
16 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)  
16 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)  
Single Wire Assembly (24 inch) / Module de fil  
Wire Assembly (24 feet) / Module de fil  
Pilot Tube / Tube de veilleuse  
526-800  
049-555A  
089-550A  
446-301  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
CFL-24-B  
Beginning Manufacturing Date: 7/98  
Ending Manufacturing Date: ______  
Service Parts  
(NG, LP) Exploded Parts Diagram  
(GN, PL) Vue éclatée des pièces  
15  
13  
11  
10  
12  
14  
8
9
2
3
4
16  
5
1
6
7
Part number list on following page.  
*
*
La liste des numéros de pièce se trouve à la page suivante.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
Service Parts List / Liste des pièces de rechange  
CFL-24-B  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,  
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est  
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une  
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.  
ITEM /  
PIÈCE  
SERIAL #  
/ N° DE SÉRIE  
PART NUMBER  
/ N° DE PIÈCE  
DESCRIPTION  
1
1
Valve NG / Valve GN  
Valve LP / Valve PL  
060-500  
060-501  
446-512A  
446-513A  
446-505  
446-517  
446-511  
060-512  
526-326A  
526-326A  
477-301A  
526-360  
302-320A  
060-511  
291-513  
Pilot Assembly NG / Module de veilleuse GN  
Pilot Assembly PL / Module de veilleuse PL  
Pilot Orifice NG / Orifice de veilleuse GN  
Pilot Orifice PL / Orifice de veilleuse PL  
Thermocouple / Thermocouple  
Thermopile / Thermopile  
2
2
3
4
5
6
7
Burner NG / Brûleur GN  
Burner LP / Brûleur PL  
Burner Tube / Tube de brûleur  
Grate Assembly / Grille  
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle  
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT  
Piezo Ignitor / Allumage Piézo  
SRV481-766  
SRV481-755  
8 & 9 Must order both logs) / Bûches  
PRE  
4-04  
POST 4-04  
POST 4-04  
8
9
Logs 1 and 2 / Bûches 1 and 2  
Logs 3 and 4 / Bûches 3 and 4  
SRV481-766  
SRV481-755  
10 Log 5 / Bûche 5  
11 Log 6 / Bûche 6  
SRV526-701  
SRV481-705  
12 Log 7 / Bûche 7  
SRV446-702  
SRV481-703  
SRV402-701  
SRV446-706  
526-801  
13 Log 8 / Bûche 8  
14 Log 9 / Bûche 9  
15 Log 10 / Bûche 10  
16 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)  
16 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)  
Single Wire Assembly (24 inch) / Module de fil  
Wire Assembly (24 feet) / Module de fil  
Pilot Tube / Tube de veilleuse  
526-800  
049-555A  
089-550A  
446-301  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
CFL-30-B  
Beginning Manufacturing Date: 7/98  
Ending Manufacturing Date: ______  
Service Parts  
(NG, LP) Exploded Parts Diagram  
(GN, PL) Vue éclatée des pièces  
13  
15  
14  
16  
11  
8
9
10  
12  
8
9
2
3
4
17  
5
1
6
7
Part number list on following page.  
*
*
La liste des numéros de pièce se trouve à la page suivante.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Service Parts List / Liste des pièces de rechange  
CFL-30-B  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,  
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est  
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une  
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.  
ITEM /  
PIÈCE  
SERIAL #  
/N° DE SÉRIE  
PART NUMBER  
/ N° DE PIÈCE  
DESCRIPTION  
1
1
Valve NG / Valve GN  
Valve LP / Valve PL  
060-500  
060-501  
446-512A  
446-513A  
446-505  
446-517  
446-511  
060-512  
526-326A  
526-326A  
477-301A  
526-360  
302-320A  
060-511  
291-513  
Pilot Assembly NG / Module de veilleuse GN  
Pilot Assembly PL / Module de veilleuse PL  
Pilot Orifice NG / Orifice de veilleuse GN  
Pilot Orifice PL / Orifice de veilleuse PL  
Thermocouple / Thermocouple  
Thermopile / Thermopile  
2
2
3
4
5
6
7
Burner NG / Brûleur GN  
Burner LP / Brûleur PL  
Burner Tube / Tube de brûleur  
Grate Assembly / Grille  
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle  
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT  
Piezo Ignitor / Allumage Piézo  
SRV526-766  
SRV526-755  
8 & 9 Must order both logs / Bûches  
PRE  
4-04  
POST 4-04  
POST 4-04  
8
9
Logs 1 and 2 / Bûches 1 and 2  
Logs 3 and 4 / Bûche 3 and 4  
SRV526-766  
SRV526-755  
10 Log 5 / Bûche 5  
11 Log 6 / Bûche 6  
SRV526-701  
SRV481-705  
12 Log 7 / Bûche 7  
SRV446-702  
SRV481-704  
SRV446-705  
SRV446-706  
SRV530-703  
526-801  
13 Log 8 / Bûche 8  
14 Log 9 / Bûche 9  
15 Log 10 / Bûche 10  
16 Log 11 / Bûche 11  
17 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)  
17 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)  
Single Wire Assembly (24 inch) / Module de fil  
Wire Assembly (24 feet) / Module de fil  
Pilot Tube / Tube de veilleuse  
526-800  
049-555A  
089-550A  
446-301  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
ST-CFL-24  
Beginning Manufacturing Date: 7-98  
Ending Manufacturing Date: ______  
Service Parts  
(NG, LP) Exploded Parts Diagram  
(GN, PL) Vue éclatée des pièces  
15  
16  
13  
12  
9
17  
10  
8
18  
14  
11  
9
10  
3
2
19  
4
5
1
6
7
4
Part number list on following page.  
*
*
La liste des numéros de pièce se trouve à la page suivante.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Service Parts List / Liste des pièces de rechange  
ST-CFL-24  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,  
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est  
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une  
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.  
ITEM /  
PIÈCE  
SERIAL #  
/N°DE SÉRIE  
PART NUMBER  
/ N° DE PIÈCE  
DESCRIPTION  
1
1
Valve NG / Valve GN  
Valve LP / Valve PL  
060-500  
060-501  
446-512A  
446-513A  
446-505  
446-517  
446-511  
Pilot Assembly NG / Module de veilleuse GN  
Pilot Assembly PL / Module de veilleuse PL  
Pilot Orifice NG / Orifice de veilleuse GN  
Pilot Orifice PL / Orifice de veilleuse PL  
Thermocouple / Thermocouple  
Thermopile / Thermopile  
060-512  
569-701A  
569-701A  
477-301A  
526-360  
302-320A  
2
2
3
4
5
Burner NG / Brûleur GN  
Burner LP / Brûleur PL  
Burner Tube / Tube de brûleur  
Grate Assembly / Grille  
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle  
6
7
8
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT  
Piezo Ignitor / Allumage Piézo  
060-511  
291-513  
Logs 1 / Bûches 1  
SRV569-710  
SRV481-755  
SRV569-711  
9 & 10 Must order both logs / Bûches  
PRE  
4-04  
POST 4-04  
POST 4-04  
9
Logs 2 and 3 / Bûches 2 and 3  
SRV569-711  
SRV481-755  
SRV569-708  
SRV569-709  
SRV569-704  
SRV569-706  
SRV569-707  
SRV569-702  
SRV569-703  
SRV569-705  
LOGS-STCFL  
526-801  
10  
11  
12  
13  
14  
15  
16  
17  
18  
Logs 4 and 5 / Bûches 4 and 5  
Log 6 / Bûche 6  
Log 7 / Bûche 7  
Log 8 / Bûche 8  
Log 9 / Bûche 9  
Log 10 / Bûche 10  
Log 11 / Bûche 11  
Log 12 / Bûche 12  
Log 13 / Bûche 13  
Log Set Assembly / Jeu de bûches  
Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)  
Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)  
Single Wire Assembly (24 inch) / Module de fil  
Wire Assembly (24 feet) / Module de fil  
Pilot Tube / Tube de veilleuse  
19  
19  
526-800  
049-555A  
089-550A  
446-301  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
Gas Log Positioning  
19 1/2  
TOP VIEW  
23 1/2  
MINIMUM FIREPLACE SIZE  
FRONT WIDTH : 23 1/2” (750mm)  
REAR WIDTH : 19 1/2” (521mm)  
13 1/2  
DEPTH  
HEIGHT  
: 13 1/2” (331mm)  
: 22” (508mm)  
FIGURE 1. MODEL CFL-18-B  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
Gas Log Positioning  
22  
MINIMUM FIREPLACE SIZE  
FRONT WIDTH: 27 1/2” (750mm)  
REAR WIDTH : 22” (521mm)  
TOP VIEW  
15 1/2  
DEPTH  
HEIGHT  
: 15 1/2” (331mm)  
: 22” (508mm)  
27 1/2  
FIGURE 2. MODEL CFL-24-B  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Gas Log Positioning  
24  
TOP VIEW  
30  
MINIMUM FIREPLACE SIZE  
FRONT WIDTH: 30” (750mm)  
REAR WIDTH : 24” (521mm)  
15 1/2  
DEPTH  
HEIGHT  
: 15 1/2” (331mm)  
: 22” (508mm)  
FIGURE 3. MODEL CFL-30-B  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
Gas Log Positioning  
24  
MINIMUM FIREPLACE SIZE  
FRONT WIDTH : 24” (521mm)  
REAR WIDTH : 24” (521mm)  
17  
TOP VIEW  
DEPTH  
HEIGHT  
: 17” (331mm)  
: 20” (508mm)  
24  
FIGURE 4. MODEL ST-CFL-24  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
1.0 INTRODUCTION  
CAUTION: CHECK THE CONSTRUCTION OF  
THE FIREPLACE BEFORE INSTALLING THE GAS  
LOG SET. THE AREA OF THE FLUE SHOULD NOT  
BE LESS THAN 1/11 THEAREAOF THE FIREPLACE  
OPENING NON-AIRTIGHT GLASS DOORS SHOULD  
BE INSTALLED ON THE FIREPLACE IF THE AREA  
OF THE FLUE IS LESS THAN 1/11 THEAREAOF THE  
FIREPLACE OPENING.  
The information in this manual pertains to Models CFL-  
18 NG/LP-B, CFL-24 NG/LP-B, CFL-30 NG/LP-B and  
ST-CFL-24NG/LP.  
Gas Log Sets are Decorative GasAppliances for Instal-  
lation in a Solid-fuel Burning Fireplace. Minimum fire-  
place sizes for these models are shown in Figures 1, 2,  
3 and 4.  
WARNING: This log set must NOT be installed in  
CAUTION: To minimize the possibility of spillage  
and to maximize proper draft, position the log set as  
close to the back of the fireplace as possible. The ST-  
CFL-24 log set should be positioned in the center of  
the unit.  
an unvented appliance.  
This log set is to be installed only in a solid-fuel burn-  
ing fireplace with a working flue and one constructed  
of noncombustible material. The minimum permanent  
vent opening provided by the fireplace chimney damper  
to vent the flue products must not be less than 51  
square inches (328cm2). The chimney damper MUST  
be fixed in a manner to maintain the minimum perma-  
nent vent opening. This may be accomplished by fas-  
tening the damper stop clamp provided to the edge of  
the damper to prevent its closing.  
The installation, including provisions for combustion and  
ventilation air, must conform with the National Fuel Gas  
Code ANSI Z223.1 (in the United States), the CAN/  
CGA B-149 Installation Code (in Canada) and appli-  
cable local building codes.  
These models can be installed in a bedroom (in the  
United States) which has a total volume of unconfined  
space appropriate to the particular installation. Refer  
to the National Fuel Gas CodeANSI Z223.1/NFPA54-  
(current edition). The Uniform Mechanical Code (cur-  
rent edition), and Local Building Officials for the options  
allowed in obtaining an effective bedroom volume of un-  
confined space.  
WARNING: OPEN THE CHIMNEY DAMPER TO  
ITS FULLY OPEN POSITION WHEN BURNING THIS  
GAS LOG SET.  
WARNING: LOGS MUST NEVER BE BURNED  
WITHOUT THE FLUE DAMPER IN THE FULL OPEN  
POSITION. FAILURE TO DO SO IS DANGEROUS  
TO YOUR HEALTH AND VOIDS ALL WARRANTIES.  
Always keep the appliance area clear and free from  
combustible materials, gasoline, and other flammable  
vapors and liquids.  
WARNING: ALL GAS APPLIANCES PRODUCE  
SOME CARBON MONOXIDE WHEN OPERATED.  
CARBON MONOXIDE IS A COLORLESS, ODOR-  
LESS, POISONOUS GAS. ADEQUATE PROVISIONS  
MUST BE MADE TO PROVIDE COMBUSTION AIR  
FOR THIS GAS LOG SET. IF OUTSIDE AIR IS NOT  
INCLUDED IN THE FIREPLACE, IT MAY BE NEC-  
ESSARY THAT AN ADDITIONAL COMBUSTION AIR  
SOURCE BE PROVIDED.  
Do not use this appliance if any part has been under  
water. Immediately call a qualified service technician to  
inspect the unit and to replace any part of the control  
system and any gas control which has been under water.  
WARNING: THIS UNIT IS NOT FOR USE WITH  
SOLID FUEL. SOLID FUELS SHALL NOT BE  
BURNED IN A FIREPLACE WHEREA DECORATIVE  
APPLIANCE IS INSTALLED.  
2.0 ASSEMBLY  
CAUTION: WHEN INSTALLING THIS LOG SET IN  
A FACTORY BUILT FIREPLACE, BE CERTAIN TO  
CONSULT THE FIREPLACE INSTALLATION  
MANUAL. ALL KNOCKOUTS IN THE FIREPLACE  
THROUGH WHICH THE GAS SUPPLY LINE IS RUN  
MUST BE RESEALED WITH INSULATION AFTER  
THE GAS LINE IS IN PLACE.  
assembly to the rear of the fireplace. The ST-CFL-24 log  
set should be positioned in the center of the unit. Once  
fully assembled, the front log will extend forward of the  
burner assembly.  
A. Run proper size gas line into fireplace. A 1/2 inch  
(13mm) gas line, with a 3/8 inch (10mm) reduction for  
hook-up, is usually sufficient for the Gas Log set; how-  
ever, if the run is unusually long, a larger line may be  
required. Contact your local gas company or Depart-  
ment of Building and Safety if there are any questions.  
These models contain complete gas-burner, grate(s),  
and log components needed. Use caution when han-  
dling logs to avoid damage. Position the gas-burner  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
B. Minimum inlet gas supply pressure for purposes of  
input adjustment, shall be 7.0 inches w.c. (1.75kPa)  
for natural gas and 11.0 inches w.c. (2.75kPa) for pro-  
pane (LP gas). Maximum inlet gas supply pressure  
shall be 14.0 in. w.c. (3.5kPa) for both natural gas and  
propane (LP gas). Manifold (outlet) pressure should  
be 3.5 inches w.c. (.87kPa) for natural gas and 10.0  
inches w.c. (2.5kPa) for LP gas.  
WARNING: OPEN THE CHIMNEY DAMPER TO ITS  
FULLYOPEN POSITION WHEN BURNINGTHIS GAS  
LOG SET.  
WARNING: LOGS MUST NEVER BE BURNED WITH-  
OUT THE FLUE DAMPER IN THE FULL OPEN POSI-  
TION. FAILURETO DO SO IS DANGEROUSTOYOUR  
HEALTHAND VOIDSALL WARRANTIES.  
H. NOTE: The Commonwealthof Massachusetts re-  
quires that the chimney flue damper, when used with  
gas logs, shall be welded open or completely removed.  
C. The appliance and its individual shut off valve must  
be disconnected from the gas supply piping system  
during any pressure testing of the system at test pres-  
sures in excess of 1/2 psig (3.5kPa).  
I. Your appliance control system is a millivolt type. It  
consists of a pilot burner, a gas control valve/regulator,  
a thermopile, a piezo ignitor, and an ON/OFF rocker  
switch. See Figure 6 for control system wiring diagram.  
D. This appliance must be isolated from the gas sup-  
ply piping system by closing its individual manual shut  
off valve during any pressure testing of the gas supply  
piping system at test pressures equal to or less than  
1/2 psig (3.5kPa).  
J. NOTE: An Optional Remote Control Kit and Wall  
Switch Kit , for turning the burner ON/OFF are avail-  
able. Detailed installation instructions are found in each  
kit.  
E. NOTE: THE GAS SUPPLY LINE SHOULD BE  
PURGED OF ANY TRAPPED AIR PRIOR TO THE  
FIRST FIRING OF THE UNIT.  
K. Test fire the unit after referring to the SAFETY IN-  
FORMATION and LIGHTING INSTRUCTIONS found  
in Section 3 in this manual, or on the label plate as-  
sembly found on the gas-burner.  
F. CAUTION: During the initial purging and sub-  
sequent lightings, NEVER allow the gas control  
valve knob to remain depressed in the "PILOT" po-  
sition without pushing the red ignitor button at least  
once every second.  
L. After the gas line installation is complete, all con-  
nections must be tightened and checked for leaks with  
a commercially-available, non-corrosive leak check  
solution. Be sure to rinse off all leak check solution  
following testing. Refer to Section 3, OPERATING  
GUIDELINES and MAINTENANCE INSTRUCTIONS.  
G. A damper stop clamp with set screw is provided to  
prevent full closure of the fireplace damper blade. At-  
tach the clamp to the edge of the damper blade with  
pliers or wrenches. If the damper stop supplied does  
not fit the application, use a permanent means that will  
keep the damper open to a MINIMUM of 51 square  
inches (328cm2). See Figure 5.  
M. Once the gas-burner is test fired and gas supply  
lines are purged, assemble the grate(s) and logs. Be  
certain to follow the Log Placement Instructions shipped  
with your unit. Remember to keep the Log Instructions  
along with this manual for future use.  
Figure 5  
Figure 6  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
3.0 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS  
Upon completing the gas line connection, a small amount  
of air will be in the lines. When first lighting the pilot  
light, it will take a few minutes for the lines to purge  
themselves of this air. Once the purging is complete,  
the pilot and burner will light and operate as indicated  
in the instruction manual. Subsequent lighting of the  
appliance will not require such purging.  
CFL-18-B  
CFL-24-B  
CFL-30-B  
WARNING:  
ST-CFL24  
Be sure fireplace screen or glass doors are in place  
when burning fireplace logs. Unless other provisions  
for combustion air are provided, the screen or  
doors shall have an opening for introduction of  
combustion air. THIS GAS LOG SET IS NOT DE-  
Figure 8  
LPG (PROPANE) INFORMATION  
SIGNED TO OPERATE WITH AIR TIGHT GLASS  
DOORS. If gas odor is noticeable, turn control knob to  
"OFF" position and check all connections for leaks. DO  
NOT USE OPEN FLAME. Adequate combustion and  
cooling air must be provided or the unit will not  
function properly.  
THE FOLLOWING WARNING APPLIES TO IN-  
STALLATIONS USING L.P. (PROPANE) GAS:  
WARNING: To avoid possible injury, fire and explo-  
sion, please read and follow these precautions and all  
instructions on this appliance before lighting the pilot.  
This appliance uses L.P. (Propane) gas which is  
heavier than air and will remain at floor level if  
there is a leak. Before lighting, smell at floor level  
and/or use other means (such as using a commer-  
cially-available, non-corrosive leak check solution on all  
piping and connections, using a gas detector, etc.) to  
check for gas leaks. NOTE: L.P. (Propane) gas can  
become odorless and CANNOT always be detected  
by smell. If you smell gas, detect a gas leak, or sus-  
pect that a gas leak exists, follow these rules.  
To obtain proper operation, it is imperative that the pi-  
lot and main burner flame characteristics are steady,  
not lifting or floating.  
Typically, the top 3/8 inch (10mm) of the thermopile  
should be engulfed in the pilot flame (Figure 7).  
Periodically remove the logs and examine the burner. If  
dirty, clean with a soft brush. Also examine the area  
around the burner air shutter and the pilot. Any dirt or  
lint in this area should be removed. This will ensure  
long life and trouble-free operation. When the appliance  
is put back in service, check the burner flame patterns  
with Figure 8.  
1. Get all people out of building.  
2. DO NOT light matches. DO NOT turn electric  
lights or switches on or off in area. DO NOT use an  
electric fan to remove gas from area. DO NOT  
use a telephone inside the building.  
3. Shut off gas at L.P. tank outside of building.  
4. Telephone gas company and fire department and  
ask for instructions.  
The appliance and venting system should be inspected  
before initial use and inspected and cleaned at least  
annually by a qualified field service person.  
Before hanging up, give your name, address and phone  
number. DO NOT go back into building.  
If your L.P. tank runs out of fuel, turn off gas at the  
appliance. After L.P. tank is refilled, appliance must be  
re-lit according to manufacturer’s instructions. If the gas  
control has been exposed to WATER in any way, DO  
NOT try to use it. It must be replaced. DO NOT attempt  
repair on gas control or appliance.  
Tampering is DANGEROUS and voids all warranties.  
Any component that is found to be faulty must be re-  
placed with an approved component.  
Figure 7  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
SAFETY INFORMATION  
FOR YOUR SAFETY READ BEFORE LIGHTING  
WARNING:  
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION  
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.  
A. This appliance has a pilot which must be  
lighted by hand. When lighting the pilot, fol-  
low these instructions exactly.  
C. Use only your hand to push in or turn the gas  
control knob. Never use tools. If the knob will  
not push in or turn by hand, don’t try to repair  
it, call a qualified service technician. Force or  
attempted repair may result in a fire or explo-  
sion.  
B. BEFORE LIGHTING smell all around the ap-  
pliance area for gas. Be sure to smell next to  
the floor because some gas is heavier than  
air and will settle on the floor.  
D. Do not use this appliance if any part has been  
under water. Immediately call a qualified ser-  
vice technician to inspect the appliance and to  
replace any part of the control system and any  
gas control which has been under water.  
WHAT TO DO IF YOU SMELL GAS  
Do not try to light any appliance.  
Do not touch any electric switch; do not use  
any phone in your building.  
Immediately call your gas supplier from a  
neighbor’s phone. Follow the gas supplier’s  
instructions.  
If you cannot reach your gas supplier, call the  
fire department.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
LIGHTING INSTRUCTIONS  
LIGHTING INSTRUCTIONS  
1. "STOP!" Readthesafetyinformationonprevious  
page.  
THERMOPILE  
PILOT BURNER  
2. Openthecontrolaccesscover(logs#3and4in  
CFL models) or (logs #4 and 5 in ST-CFL  
model),refertoyourLogPlacementInstructions.  
3. Turn the valve control knob to the "OFF"  
position. To do this, you must turn the knob  
6. To put the control in the "Pilot" position, turn the  
control knob counter-clockwise  
"Pilot" position.  
to the  
clockwise  
then press in and continue turning  
clockwise to the "OFF" position.  
to the "Pilot" position, and  
7. Tolightthepilotdepressthecontrolknobandthen  
depress the red piezo button until it makes a  
clicking sound. It may be necessary to repeat this  
step. Ifthepilotdoesnotlightafter10seconds,go  
back to step 3. The control knob should be held  
down for a MINUTE after pilot ignition.  
• If the control knob does not pop out when  
released, STOP-shut off the gas supply to  
the fireplace control valve, and IMMEDI-  
ATELY call your service technician or gas  
supplier.  
GAS CONTROL VALVE  
NOTE: Knobcannotbeturnedfrom"PILOT"to  
"OFF"unlessknobispushedinslightly. Donot  
force.  
• If the pilot will not stay lit after two tries, turn  
the control knob to the "OFF" position and  
call your service technician or gas supplier.  
4. WAIT FIVE (5) MINUTES TO CLEAR OUT  
ANY GAS. Then smell for gas, including near  
the floor. If you then smell gas, STOP! Follow  
"B" in the safety information previous page. If  
you don't smell gas, go to the next step.  
8. Afterthepilothasbeenlit,theburnercanbeturned  
on by turning the knob counter-clockwise  
to the "ON" position. Flip the ON/OFF  
switch to the "ON" position. (This is located to the  
right on the burner leg and behind the control  
accesscover.)  
5. The pilot should not require accessing for  
lighting purposes. The pilot is located at the  
end of the burner.  
9. Close control access cover.  
TO TURN OFF GAS APPLIANCE  
1. Turn ON/OFF switch to "OFF".  
2. Open the control access cover.  
3. Turn the valve control knob clockwise  
to the "Pilot" position, then depress knob and  
continue turning to "OFF" position.  
4. Close control access cover.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
4.0 HIGH ELEVATION INSTALLATION  
for elevations between 2000 and 4500 feet in Canada.  
If the heating value of the gas has been reduced, these  
rules do not apply. To identify the proper orifice size,  
check with the local gas utility.  
U.L. Listed gas appliances are tested and approved  
without requiring changes for elevations from 0 to 2,000  
feet in the U. S. A. and in Canada.  
When installing this appliance at an elevation above  
2,000 feet, it may be necessary to decrease the input  
rating by changing the existing burner orifice to a smaller  
size. Input rate should be reduced by 4% for each 1000  
feet above a 2000 foot elevation in the U.S.A. or 10%  
If installing this appliance at an elevation above 4,500  
feet (in Canada), check with local authorities.  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
!
LIMITED LIFETIME WARRANTY  
HEAT & GLO GAS APPLIANCE PRODUCTS  
BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington  
Boulevard, Lakeville, MN 55044, (HEAT & GLO”) warrants to the original owner that your new HEAT& GLO GasAppliance (the Product)  
will be free from defects in materials and workmanship for a period of one year from the date of installation. During the first year, HEAT & GLO  
will replace or repair, at its discretion, any defective components at its sole cost and expense, including payment of all reasonable labor costs  
incurred in replacing or repairing such components. This basic warranty is subject to the conditions, exclusions and limitations described below.  
EXTENDED LIFETIME COVERAGE. HEAT & GLO warrants that the firebox, heat exchanger, log(s), and burner will not be defective in  
material or workmanship during the period the Product is owned by the original owner, subject to the following conditions, exclusions and  
limitations described below.  
CONDITIONS, EXCLUSIONSAND LIMITATIONS:  
1. This warranty applies to the original owner only and is nontransferable.  
2. This warranty applies only to Products installed in the United States ofAmerica or Canada.  
3. This warranty is limited to the replacement or repair of defective components or workmanship and HEAT & GLO may fully discharge all  
obligations under this warranty by repairing or replacing, at its discretion, the defective components. The maximum amount recoverable  
under this warranty is limited to the purchase price of the Product and, if HEAT& GLO is unable to provide replacement or repair in an  
expedient and cost-effective manner, HEAT& GLO may discharge all obligations under this warranty by refunding the purchase price of  
the Product. IN NO EVENTSHALLHEAT & GLO BE LIABLE FORANYINCIDENTALOR CONSEQUENTIALDAMAGES CAUSED BY  
DEFECTS IN THE PRODUCT.  
4. Any labor and related repair charges relating to the costs and expenses of replacing or repairing defective components under the Limited  
Lifetime Warranty are not covered by this warranty, except as provided for under the Basic One-Year Warranty.  
5. Components and parts made by other manufacturers, whether sold with the Product or added thereafter, are NOT covered by this  
warranty unless expressly authorized and approved by HEAT & GLO in writing.  
6. Any damages caused by environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure,  
air handling devices such as exhaust fans or forced air furnaces, or other such causes are not covered by this warranty.  
7. This warranty will be void if:  
a) The Product is not installed, operated and maintained in compliance with local building codes and with the instructions in the Installers  
Guide, Owners Guide and ListingAgent Identification Label furnished with the Product.  
b) Any parts or components made by other manufacturers are added or used in the Product, unless expressly authorized and  
approved by HEAT & GLO in writing.  
c) Any service work is performed on the Product by anyone other than an authorized HEAT & GLO representative.  
d) The Product is damaged due to shipping, improper handling, accident, abuse or misuse.  
e) Fuels other than those specified in the Installers Guide and Owners Guide are used.  
f) Modification was made to the Product which was not expressly authorized and approved by HEAT & GLO in writing.  
EXCEPT TO THE EXTENT PROVIDED BY LAW, HEAT & GLO MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY  
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO THE DURATION OF THE WARRANTY SPEC-  
IFIED ABOVE.  
Some states do not allow limitations on how long an implied warranty lasts, or do not allow exclusion or limitation of incidental or consequential  
damages, so those limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary  
from State to State.  
If warranty service is needed you should contact your installing dealer and if the installing dealer is unable to provide necessary parts or  
components, contact the nearest authorized HEAT& GLO dealer or supplier.  
NOTES TO CUSTOMER:  
1. In order to insure proper installation, operation and maintenance HEAT & GLO strongly recommends annual  
servicing by an authorized HEAT & GLO dealer.  
2. Please complete this information and retain this warranty in a safe place for future reference: Installation Date:______  
Model #:_________________ Serial #:______________ Installing Contractor:_________________________  
3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications  
and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products.  
© 2005 Hearth & Home Technologies Inc.  
060-981D 3/05  
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco High Chair 3170 User Manual
Grizzly Outboard Motor G2908 User Manual
Harbor Freight Tools Binoculars 65730 User Manual
Hauppauge Computer Hardware WinTV HVR 1800 User Manual
Heath Zenith Work Light PF 4291 BK User Manual
Honeywell Scanner MS5100 Series User Manual
HP Hewlett Packard Switch 3500yl Series User Manual
HP Hewlett Packard Weather Radio HP 16532A 1 User Manual
HTC Cell Phone HD7 User Manual
Husqvarna Tiller T 350 User Manual