INSTALLATIONAND OPERATION INSTRUCTIONS
MODEL CFL-18NG-B, CFL-24NG-B,
MODEL CFL-18LP-B, CFL-24LP-B,
CFL-30LP-B, ST-CFL-24LP:
LPGAS(PROPANE)
CFL-30NG-B, ST-CFL-24NG:
NATURALGAS
READ THIS MANUAL BEFORE INSTALLATION AND
LEAVE IT WITH THE APPLIANCE FOR OPERATION AND MAINTENANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Underwriters Laboratories
-
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
Listed
• Do not touch any electrical switch; do not
use any phone in your building.
WARNING:
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas
supplier's instructions.
Improper installation, adjustment, alter-
ation, service or maintenance can cause
injury or property damage. Refer to the
owner's information manual provided with
this appliance. For assistance or addi-
tional information consult a qualified in-
staller, service agency or the gas supplier.
• If you cannot reach your gas supplier, call
the fire department.
-
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
Copyright 2005
Please contact your Heat & Glo dealer with
any questions or concerns. For the number
of your nearest Heat & Glo dealer, please call
888-427-3973
Heat & Glo, a brand of Hearth & Home Technologies
20802 Kensington Blvd., Lakeville, Mn 55044
Printed in U.S.A.
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471,
5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165,
6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174,
D462436; (Canada) 1297749, 2195264, 2225408; or other U.S. and foreign patents pending.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
1
Download from Www.Somanuals.com. All Manuals Search And Download.
CFL-18-B
Beginning Manufacturing Date: 7/98
Ending Manufacturing Date: ______
Service Parts
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
13
15
11
10
9
12
14
8
2
3
16
5
1
Part number list on following page.
La liste des numéros de pièce se
*
6
7
*
trouve à la page suivante.
4
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Service Parts List / Liste des pièces de rechange
CFL-18-B
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une
ITEM /
PIÈCE
SERIAL #
/N° DE SÉRIE
PART NUMBER
/ N° DE PIÈCE
DESCRIPTION
1
1
Valve NG / Valve GN
Valve LP / Valve PL
060-500
060-501
446-512A
446-513A
446-505
446-517
446-511
060-512
526-326A
526-326A
477-301A
526-360
302-320A
060-511
291-513
Pilot Assembly NG / Module de veilleuse GN
Pilot Assembly PL / Module de veilleuse PL
Pilot Orifice NG / Orifice de veilleuse GN
Pilot Orifice PL / Orifice de veilleuse PL
Thermocouple / Thermocouple
Thermopile / Thermopile
2
2
3
4
5
6
7
Burner NG / Brûleur GN
Burner LP / Brûleur PL
Burner Tube / Tube de brûleur
Grate Assembly / Grille
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT
Piezo Ignitor / Allumage Piézo
SRV481-766
SRV481-755
8 & 9 Must order both logs / Bûches
PRE
4-04
POST 4-04
POST 4-04
8
9
Logs 1 and 2 / Bûches 1 and 2
Logs 3 and 4 / Bûches 3 and 4
SRV481-766
SRV481-755
10 Log 5 / Bûche 5
11 Log 6 / Bûche 6
SRV481-701
SRV481-705
12 Log 7 / Bûche 7
SRV446-702
SRV481-703
SRV402-701
SRV446-706
526-801
13 Log 8 / Bûche 8
14 Log 9 / Bûche 9
15 Log 10 / Bûche 10
16 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)
16 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)
Single Wire Assembly (24 inch) / Module de fil
Wire Assembly (24 feet) / Module de fil
Pilot Tube / Tube de veilleuse
526-800
049-555A
089-550A
446-301
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
4
CFL-24-B
Beginning Manufacturing Date: 7/98
Ending Manufacturing Date: ______
Service Parts
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
15
13
11
10
12
14
8
9
2
3
4
16
5
1
6
7
Part number list on following page.
*
*
La liste des numéros de pièce se trouve à la page suivante.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Service Parts List / Liste des pièces de rechange
CFL-24-B
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
SERIAL #
/ N° DE SÉRIE
PART NUMBER
/ N° DE PIÈCE
DESCRIPTION
1
1
Valve NG / Valve GN
Valve LP / Valve PL
060-500
060-501
446-512A
446-513A
446-505
446-517
446-511
060-512
526-326A
526-326A
477-301A
526-360
302-320A
060-511
291-513
Pilot Assembly NG / Module de veilleuse GN
Pilot Assembly PL / Module de veilleuse PL
Pilot Orifice NG / Orifice de veilleuse GN
Pilot Orifice PL / Orifice de veilleuse PL
Thermocouple / Thermocouple
Thermopile / Thermopile
2
2
3
4
5
6
7
Burner NG / Brûleur GN
Burner LP / Brûleur PL
Burner Tube / Tube de brûleur
Grate Assembly / Grille
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT
Piezo Ignitor / Allumage Piézo
SRV481-766
SRV481-755
8 & 9 Must order both logs) / Bûches
PRE
4-04
POST 4-04
POST 4-04
8
9
Logs 1 and 2 / Bûches 1 and 2
Logs 3 and 4 / Bûches 3 and 4
SRV481-766
SRV481-755
10 Log 5 / Bûche 5
11 Log 6 / Bûche 6
SRV526-701
SRV481-705
12 Log 7 / Bûche 7
SRV446-702
SRV481-703
SRV402-701
SRV446-706
526-801
13 Log 8 / Bûche 8
14 Log 9 / Bûche 9
15 Log 10 / Bûche 10
16 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)
16 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)
Single Wire Assembly (24 inch) / Module de fil
Wire Assembly (24 feet) / Module de fil
Pilot Tube / Tube de veilleuse
526-800
049-555A
089-550A
446-301
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
6
CFL-30-B
Beginning Manufacturing Date: 7/98
Ending Manufacturing Date: ______
Service Parts
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
13
15
14
16
11
8
9
10
12
8
9
2
3
4
17
5
1
6
7
Part number list on following page.
*
*
La liste des numéros de pièce se trouve à la page suivante.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Service Parts List / Liste des pièces de rechange
CFL-30-B
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
SERIAL #
/N° DE SÉRIE
PART NUMBER
/ N° DE PIÈCE
DESCRIPTION
1
1
Valve NG / Valve GN
Valve LP / Valve PL
060-500
060-501
446-512A
446-513A
446-505
446-517
446-511
060-512
526-326A
526-326A
477-301A
526-360
302-320A
060-511
291-513
Pilot Assembly NG / Module de veilleuse GN
Pilot Assembly PL / Module de veilleuse PL
Pilot Orifice NG / Orifice de veilleuse GN
Pilot Orifice PL / Orifice de veilleuse PL
Thermocouple / Thermocouple
Thermopile / Thermopile
2
2
3
4
5
6
7
Burner NG / Brûleur GN
Burner LP / Brûleur PL
Burner Tube / Tube de brûleur
Grate Assembly / Grille
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT
Piezo Ignitor / Allumage Piézo
SRV526-766
SRV526-755
8 & 9 Must order both logs / Bûches
PRE
4-04
POST 4-04
POST 4-04
8
9
Logs 1 and 2 / Bûches 1 and 2
Logs 3 and 4 / Bûche 3 and 4
SRV526-766
SRV526-755
10 Log 5 / Bûche 5
11 Log 6 / Bûche 6
SRV526-701
SRV481-705
12 Log 7 / Bûche 7
SRV446-702
SRV481-704
SRV446-705
SRV446-706
SRV530-703
526-801
13 Log 8 / Bûche 8
14 Log 9 / Bûche 9
15 Log 10 / Bûche 10
16 Log 11 / Bûche 11
17 Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)
17 Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)
Single Wire Assembly (24 inch) / Module de fil
Wire Assembly (24 feet) / Module de fil
Pilot Tube / Tube de veilleuse
526-800
049-555A
089-550A
446-301
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
8
ST-CFL-24
Beginning Manufacturing Date: 7-98
Ending Manufacturing Date: ______
Service Parts
(NG, LP) Exploded Parts Diagram
(GN, PL) Vue éclatée des pièces
15
16
13
12
9
17
10
8
18
14
11
9
10
3
2
19
4
5
1
6
7
4
Part number list on following page.
*
*
La liste des numéros de pièce se trouve à la page suivante.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Service Parts List / Liste des pièces de rechange
ST-CFL-24
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,
supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est
valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une
commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.
ITEM /
PIÈCE
SERIAL #
/N°DE SÉRIE
PART NUMBER
/ N° DE PIÈCE
DESCRIPTION
1
1
Valve NG / Valve GN
Valve LP / Valve PL
060-500
060-501
446-512A
446-513A
446-505
446-517
446-511
Pilot Assembly NG / Module de veilleuse GN
Pilot Assembly PL / Module de veilleuse PL
Pilot Orifice NG / Orifice de veilleuse GN
Pilot Orifice PL / Orifice de veilleuse PL
Thermocouple / Thermocouple
Thermopile / Thermopile
060-512
569-701A
569-701A
477-301A
526-360
302-320A
2
2
3
4
5
Burner NG / Brûleur GN
Burner LP / Brûleur PL
Burner Tube / Tube de brûleur
Grate Assembly / Grille
Flex Ball Valve Assembly / Fléchir l'Assemblée de Soupape de Balle
6
7
8
ON/OFF Rocker Switch / Interrupteur à bascule MARCHE/ARRÊT
Piezo Ignitor / Allumage Piézo
060-511
291-513
Logs 1 / Bûches 1
SRV569-710
SRV481-755
SRV569-711
9 & 10 Must order both logs / Bûches
PRE
4-04
POST 4-04
POST 4-04
9
Logs 2 and 3 / Bûches 2 and 3
SRV569-711
SRV481-755
SRV569-708
SRV569-709
SRV569-704
SRV569-706
SRV569-707
SRV569-702
SRV569-703
SRV569-705
LOGS-STCFL
526-801
10
11
12
13
14
15
16
17
18
Logs 4 and 5 / Bûches 4 and 5
Log 6 / Bûche 6
Log 7 / Bûche 7
Log 8 / Bûche 8
Log 9 / Bûche 9
Log 10 / Bûche 10
Log 11 / Bûche 11
Log 12 / Bûche 12
Log 13 / Bûche 13
Log Set Assembly / Jeu de bûches
Burner Orifice NG (1.55mm) / Orifice de brûleur GN (1.55mm)
Burner Orifice LP (2.30mm) / Orifice de brûleur PL (2.30mm)
Single Wire Assembly (24 inch) / Module de fil
Wire Assembly (24 feet) / Module de fil
Pilot Tube / Tube de veilleuse
19
19
526-800
049-555A
089-550A
446-301
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Gas Log Positioning
19 1/2
TOP VIEW
23 1/2
MINIMUM FIREPLACE SIZE
FRONT WIDTH : 23 1/2” (750mm)
REAR WIDTH : 19 1/2” (521mm)
13 1/2
DEPTH
HEIGHT
: 13 1/2” (331mm)
: 22” (508mm)
FIGURE 1. MODEL CFL-18-B
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Gas Log Positioning
22
MINIMUM FIREPLACE SIZE
FRONT WIDTH: 27 1/2” (750mm)
REAR WIDTH : 22” (521mm)
TOP VIEW
15 1/2
DEPTH
HEIGHT
: 15 1/2” (331mm)
: 22” (508mm)
27 1/2
FIGURE 2. MODEL CFL-24-B
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Gas Log Positioning
24
TOP VIEW
30
MINIMUM FIREPLACE SIZE
FRONT WIDTH: 30” (750mm)
REAR WIDTH : 24” (521mm)
15 1/2
DEPTH
HEIGHT
: 15 1/2” (331mm)
: 22” (508mm)
FIGURE 3. MODEL CFL-30-B
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Gas Log Positioning
24
MINIMUM FIREPLACE SIZE
FRONT WIDTH : 24” (521mm)
REAR WIDTH : 24” (521mm)
17
TOP VIEW
DEPTH
HEIGHT
: 17” (331mm)
: 20” (508mm)
24
FIGURE 4. MODEL ST-CFL-24
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
14
1.0 INTRODUCTION
CAUTION: CHECK THE CONSTRUCTION OF
THE FIREPLACE BEFORE INSTALLING THE GAS
LOG SET. THE AREA OF THE FLUE SHOULD NOT
BE LESS THAN 1/11 THEAREAOF THE FIREPLACE
OPENING NON-AIRTIGHT GLASS DOORS SHOULD
BE INSTALLED ON THE FIREPLACE IF THE AREA
OF THE FLUE IS LESS THAN 1/11 THEAREAOF THE
FIREPLACE OPENING.
The information in this manual pertains to Models CFL-
18 NG/LP-B, CFL-24 NG/LP-B, CFL-30 NG/LP-B and
ST-CFL-24NG/LP.
Gas Log Sets are Decorative GasAppliances for Instal-
lation in a Solid-fuel Burning Fireplace. Minimum fire-
place sizes for these models are shown in Figures 1, 2,
3 and 4.
WARNING: This log set must NOT be installed in
CAUTION: To minimize the possibility of spillage
and to maximize proper draft, position the log set as
close to the back of the fireplace as possible. The ST-
CFL-24 log set should be positioned in the center of
the unit.
an unvented appliance.
This log set is to be installed only in a solid-fuel burn-
ing fireplace with a working flue and one constructed
of noncombustible material. The minimum permanent
vent opening provided by the fireplace chimney damper
to vent the flue products must not be less than 51
square inches (328cm2). The chimney damper MUST
be fixed in a manner to maintain the minimum perma-
nent vent opening. This may be accomplished by fas-
tening the damper stop clamp provided to the edge of
the damper to prevent its closing.
The installation, including provisions for combustion and
ventilation air, must conform with the National Fuel Gas
Code ANSI Z223.1 (in the United States), the CAN/
CGA B-149 Installation Code (in Canada) and appli-
cable local building codes.
These models can be installed in a bedroom (in the
United States) which has a total volume of unconfined
space appropriate to the particular installation. Refer
to the National Fuel Gas CodeANSI Z223.1/NFPA54-
(current edition). The Uniform Mechanical Code (cur-
rent edition), and Local Building Officials for the options
allowed in obtaining an effective bedroom volume of un-
confined space.
WARNING: OPEN THE CHIMNEY DAMPER TO
ITS FULLY OPEN POSITION WHEN BURNING THIS
GAS LOG SET.
WARNING: LOGS MUST NEVER BE BURNED
WITHOUT THE FLUE DAMPER IN THE FULL OPEN
POSITION. FAILURE TO DO SO IS DANGEROUS
TO YOUR HEALTH AND VOIDS ALL WARRANTIES.
Always keep the appliance area clear and free from
combustible materials, gasoline, and other flammable
vapors and liquids.
WARNING: ALL GAS APPLIANCES PRODUCE
SOME CARBON MONOXIDE WHEN OPERATED.
CARBON MONOXIDE IS A COLORLESS, ODOR-
LESS, POISONOUS GAS. ADEQUATE PROVISIONS
MUST BE MADE TO PROVIDE COMBUSTION AIR
FOR THIS GAS LOG SET. IF OUTSIDE AIR IS NOT
INCLUDED IN THE FIREPLACE, IT MAY BE NEC-
ESSARY THAT AN ADDITIONAL COMBUSTION AIR
SOURCE BE PROVIDED.
Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the unit and to replace any part of the control
system and any gas control which has been under water.
WARNING: THIS UNIT IS NOT FOR USE WITH
SOLID FUEL. SOLID FUELS SHALL NOT BE
BURNED IN A FIREPLACE WHEREA DECORATIVE
APPLIANCE IS INSTALLED.
2.0 ASSEMBLY
CAUTION: WHEN INSTALLING THIS LOG SET IN
A FACTORY BUILT FIREPLACE, BE CERTAIN TO
CONSULT THE FIREPLACE INSTALLATION
MANUAL. ALL KNOCKOUTS IN THE FIREPLACE
THROUGH WHICH THE GAS SUPPLY LINE IS RUN
MUST BE RESEALED WITH INSULATION AFTER
THE GAS LINE IS IN PLACE.
assembly to the rear of the fireplace. The ST-CFL-24 log
set should be positioned in the center of the unit. Once
fully assembled, the front log will extend forward of the
burner assembly.
A. Run proper size gas line into fireplace. A 1/2 inch
(13mm) gas line, with a 3/8 inch (10mm) reduction for
hook-up, is usually sufficient for the Gas Log set; how-
ever, if the run is unusually long, a larger line may be
required. Contact your local gas company or Depart-
ment of Building and Safety if there are any questions.
These models contain complete gas-burner, grate(s),
and log components needed. Use caution when han-
dling logs to avoid damage. Position the gas-burner
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
15
B. Minimum inlet gas supply pressure for purposes of
input adjustment, shall be 7.0 inches w.c. (1.75kPa)
for natural gas and 11.0 inches w.c. (2.75kPa) for pro-
pane (LP gas). Maximum inlet gas supply pressure
shall be 14.0 in. w.c. (3.5kPa) for both natural gas and
propane (LP gas). Manifold (outlet) pressure should
be 3.5 inches w.c. (.87kPa) for natural gas and 10.0
inches w.c. (2.5kPa) for LP gas.
WARNING: OPEN THE CHIMNEY DAMPER TO ITS
FULLYOPEN POSITION WHEN BURNINGTHIS GAS
LOG SET.
WARNING: LOGS MUST NEVER BE BURNED WITH-
OUT THE FLUE DAMPER IN THE FULL OPEN POSI-
TION. FAILURETO DO SO IS DANGEROUSTOYOUR
HEALTHAND VOIDSALL WARRANTIES.
H. NOTE: The Commonwealthof Massachusetts re-
quires that the chimney flue damper, when used with
gas logs, shall be welded open or completely removed.
C. The appliance and its individual shut off valve must
be disconnected from the gas supply piping system
during any pressure testing of the system at test pres-
sures in excess of 1/2 psig (3.5kPa).
I. Your appliance control system is a millivolt type. It
consists of a pilot burner, a gas control valve/regulator,
a thermopile, a piezo ignitor, and an ON/OFF rocker
switch. See Figure 6 for control system wiring diagram.
D. This appliance must be isolated from the gas sup-
ply piping system by closing its individual manual shut
off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
J. NOTE: An Optional Remote Control Kit and Wall
Switch Kit , for turning the burner ON/OFF are avail-
able. Detailed installation instructions are found in each
kit.
E. NOTE: THE GAS SUPPLY LINE SHOULD BE
PURGED OF ANY TRAPPED AIR PRIOR TO THE
FIRST FIRING OF THE UNIT.
K. Test fire the unit after referring to the SAFETY IN-
FORMATION and LIGHTING INSTRUCTIONS found
in Section 3 in this manual, or on the label plate as-
sembly found on the gas-burner.
F. CAUTION: During the initial purging and sub-
sequent lightings, NEVER allow the gas control
valve knob to remain depressed in the "PILOT" po-
sition without pushing the red ignitor button at least
once every second.
L. After the gas line installation is complete, all con-
nections must be tightened and checked for leaks with
a commercially-available, non-corrosive leak check
solution. Be sure to rinse off all leak check solution
following testing. Refer to Section 3, OPERATING
GUIDELINES and MAINTENANCE INSTRUCTIONS.
G. A damper stop clamp with set screw is provided to
prevent full closure of the fireplace damper blade. At-
tach the clamp to the edge of the damper blade with
pliers or wrenches. If the damper stop supplied does
not fit the application, use a permanent means that will
keep the damper open to a MINIMUM of 51 square
inches (328cm2). See Figure 5.
M. Once the gas-burner is test fired and gas supply
lines are purged, assemble the grate(s) and logs. Be
certain to follow the Log Placement Instructions shipped
with your unit. Remember to keep the Log Instructions
along with this manual for future use.
Figure 5
Figure 6
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
16
3.0 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS
Upon completing the gas line connection, a small amount
of air will be in the lines. When first lighting the pilot
light, it will take a few minutes for the lines to purge
themselves of this air. Once the purging is complete,
the pilot and burner will light and operate as indicated
in the instruction manual. Subsequent lighting of the
appliance will not require such purging.
CFL-18-B
CFL-24-B
CFL-30-B
WARNING:
ST-CFL24
Be sure fireplace screen or glass doors are in place
when burning fireplace logs. Unless other provisions
for combustion air are provided, the screen or
doors shall have an opening for introduction of
combustion air. THIS GAS LOG SET IS NOT DE-
Figure 8
LPG (PROPANE) INFORMATION
SIGNED TO OPERATE WITH AIR TIGHT GLASS
DOORS. If gas odor is noticeable, turn control knob to
"OFF" position and check all connections for leaks. DO
NOT USE OPEN FLAME. Adequate combustion and
cooling air must be provided or the unit will not
function properly.
THE FOLLOWING WARNING APPLIES TO IN-
STALLATIONS USING L.P. (PROPANE) GAS:
WARNING: To avoid possible injury, fire and explo-
sion, please read and follow these precautions and all
instructions on this appliance before lighting the pilot.
This appliance uses L.P. (Propane) gas which is
heavier than air and will remain at floor level if
there is a leak. Before lighting, smell at floor level
and/or use other means (such as using a commer-
cially-available, non-corrosive leak check solution on all
piping and connections, using a gas detector, etc.) to
check for gas leaks. NOTE: L.P. (Propane) gas can
become odorless and CANNOT always be detected
by smell. If you smell gas, detect a gas leak, or sus-
pect that a gas leak exists, follow these rules.
To obtain proper operation, it is imperative that the pi-
lot and main burner flame characteristics are steady,
not lifting or floating.
Typically, the top 3/8 inch (10mm) of the thermopile
should be engulfed in the pilot flame (Figure 7).
Periodically remove the logs and examine the burner. If
dirty, clean with a soft brush. Also examine the area
around the burner air shutter and the pilot. Any dirt or
lint in this area should be removed. This will ensure
long life and trouble-free operation. When the appliance
is put back in service, check the burner flame patterns
with Figure 8.
1. Get all people out of building.
2. DO NOT light matches. DO NOT turn electric
lights or switches on or off in area. DO NOT use an
electric fan to remove gas from area. DO NOT
use a telephone inside the building.
3. Shut off gas at L.P. tank outside of building.
4. Telephone gas company and fire department and
ask for instructions.
The appliance and venting system should be inspected
before initial use and inspected and cleaned at least
annually by a qualified field service person.
Before hanging up, give your name, address and phone
number. DO NOT go back into building.
If your L.P. tank runs out of fuel, turn off gas at the
appliance. After L.P. tank is refilled, appliance must be
re-lit according to manufacturer’s instructions. If the gas
control has been exposed to WATER in any way, DO
NOT try to use it. It must be replaced. DO NOT attempt
repair on gas control or appliance.
Tampering is DANGEROUS and voids all warranties.
Any component that is found to be faulty must be re-
placed with an approved component.
Figure 7
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
17
SAFETY INFORMATION
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot, fol-
low these instructions exactly.
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will
not push in or turn by hand, don’t try to repair
it, call a qualified service technician. Force or
attempted repair may result in a fire or explo-
sion.
B. BEFORE LIGHTING smell all around the ap-
pliance area for gas. Be sure to smell next to
the floor because some gas is heavier than
air and will settle on the floor.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified ser-
vice technician to inspect the appliance and to
replace any part of the control system and any
gas control which has been under water.
WHAT TO DO IF YOU SMELL GAS
•
•
Do not try to light any appliance.
Do not touch any electric switch; do not use
any phone in your building.
•
•
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
18
LIGHTING INSTRUCTIONS
LIGHTING INSTRUCTIONS
1. "STOP!" Readthesafetyinformationonprevious
page.
THERMOPILE
PILOT BURNER
2. Openthecontrolaccesscover(logs#3and4in
CFL models) or (logs #4 and 5 in ST-CFL
model),refertoyourLogPlacementInstructions.
3. Turn the valve control knob to the "OFF"
position. To do this, you must turn the knob
6. To put the control in the "Pilot" position, turn the
control knob counter-clockwise
"Pilot" position.
to the
clockwise
then press in and continue turning
clockwise to the "OFF" position.
to the "Pilot" position, and
7. Tolightthepilotdepressthecontrolknobandthen
depress the red piezo button until it makes a
clicking sound. It may be necessary to repeat this
step. Ifthepilotdoesnotlightafter10seconds,go
back to step 3. The control knob should be held
down for a MINUTE after pilot ignition.
• If the control knob does not pop out when
released, STOP-shut off the gas supply to
the fireplace control valve, and IMMEDI-
ATELY call your service technician or gas
supplier.
GAS CONTROL VALVE
NOTE: Knobcannotbeturnedfrom"PILOT"to
"OFF"unlessknobispushedinslightly. Donot
force.
• If the pilot will not stay lit after two tries, turn
the control knob to the "OFF" position and
call your service technician or gas supplier.
4. WAIT FIVE (5) MINUTES TO CLEAR OUT
ANY GAS. Then smell for gas, including near
the floor. If you then smell gas, STOP! Follow
"B" in the safety information previous page. If
you don't smell gas, go to the next step.
8. Afterthepilothasbeenlit,theburnercanbeturned
on by turning the knob counter-clockwise
to the "ON" position. Flip the ON/OFF
switch to the "ON" position. (This is located to the
right on the burner leg and behind the control
accesscover.)
5. The pilot should not require accessing for
lighting purposes. The pilot is located at the
end of the burner.
9. Close control access cover.
TO TURN OFF GAS APPLIANCE
1. Turn ON/OFF switch to "OFF".
2. Open the control access cover.
3. Turn the valve control knob clockwise
to the "Pilot" position, then depress knob and
continue turning to "OFF" position.
4. Close control access cover.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
19
4.0 HIGH ELEVATION INSTALLATION
for elevations between 2000 and 4500 feet in Canada.
If the heating value of the gas has been reduced, these
rules do not apply. To identify the proper orifice size,
check with the local gas utility.
U.L. Listed gas appliances are tested and approved
without requiring changes for elevations from 0 to 2,000
feet in the U. S. A. and in Canada.
When installing this appliance at an elevation above
2,000 feet, it may be necessary to decrease the input
rating by changing the existing burner orifice to a smaller
size. Input rate should be reduced by 4% for each 1000
feet above a 2000 foot elevation in the U.S.A. or 10%
If installing this appliance at an elevation above 4,500
feet (in Canada), check with local authorities.
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
Download from Www.Somanuals.com. All Manuals Search And Download.
20
!
LIMITED LIFETIME WARRANTY
HEAT & GLO GAS APPLIANCE PRODUCTS
BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 Kensington
Boulevard, Lakeville, MN 55044, (“HEAT & GLO”) warrants to the original owner that your new HEAT& GLO GasAppliance (the “Product”)
will be free from defects in materials and workmanship for a period of one year from the date of installation. During the first year, HEAT & GLO
will replace or repair, at its discretion, any defective components at its sole cost and expense, including payment of all reasonable labor costs
incurred in replacing or repairing such components. This basic warranty is subject to the conditions, exclusions and limitations described below.
EXTENDED LIFETIME COVERAGE. HEAT & GLO warrants that the firebox, heat exchanger, log(s), and burner will not be defective in
material or workmanship during the period the Product is owned by the original owner, subject to the following conditions, exclusions and
limitations described below.
CONDITIONS, EXCLUSIONSAND LIMITATIONS:
1. This warranty applies to the original owner only and is nontransferable.
2. This warranty applies only to Products installed in the United States ofAmerica or Canada.
3. This warranty is limited to the replacement or repair of defective components or workmanship and HEAT & GLO may fully discharge all
obligations under this warranty by repairing or replacing, at its discretion, the defective components. The maximum amount recoverable
under this warranty is limited to the purchase price of the Product and, if HEAT& GLO is unable to provide replacement or repair in an
expedient and cost-effective manner, HEAT& GLO may discharge all obligations under this warranty by refunding the purchase price of
the Product. IN NO EVENTSHALLHEAT & GLO BE LIABLE FORANYINCIDENTALOR CONSEQUENTIALDAMAGES CAUSED BY
DEFECTS IN THE PRODUCT.
4. Any labor and related repair charges relating to the costs and expenses of replacing or repairing defective components under the Limited
Lifetime Warranty are not covered by this warranty, except as provided for under the Basic One-Year Warranty.
5. Components and parts made by other manufacturers, whether sold with the Product or added thereafter, are NOT covered by this
warranty unless expressly authorized and approved by HEAT & GLO in writing.
6. Any damages caused by environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure,
air handling devices such as exhaust fans or forced air furnaces, or other such causes are not covered by this warranty.
7. This warranty will be void if:
a) The Product is not installed, operated and maintained in compliance with local building codes and with the instructions in the Installer’s
Guide, Owner’s Guide and ListingAgent Identification Label furnished with the Product.
b) Any parts or components made by other manufacturers are added or used in the Product, unless expressly authorized and
approved by HEAT & GLO in writing.
c) Any service work is performed on the Product by anyone other than an authorized HEAT & GLO representative.
d) The Product is damaged due to shipping, improper handling, accident, abuse or misuse.
e) Fuels other than those specified in the Installer’s Guide and Owner’s Guide are used.
f) Modification was made to the Product which was not expressly authorized and approved by HEAT & GLO in writing.
EXCEPT TO THE EXTENT PROVIDED BY LAW, HEAT & GLO MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO THE DURATION OF THE WARRANTY SPEC-
IFIED ABOVE.
Some states do not allow limitations on how long an implied warranty lasts, or do not allow exclusion or limitation of incidental or consequential
damages, so those limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary
from State to State.
If warranty service is needed you should contact your installing dealer and if the installing dealer is unable to provide necessary parts or
components, contact the nearest authorized HEAT& GLO dealer or supplier.
NOTES TO CUSTOMER:
1. In order to insure proper installation, operation and maintenance HEAT & GLO strongly recommends annual
servicing by an authorized HEAT & GLO dealer.
2. Please complete this information and retain this warranty in a safe place for future reference: Installation Date:______
Model #:_________________ Serial #:______________ Installing Contractor:_________________________
3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications
and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products.
© 2005 Hearth & Home Technologies Inc.
060-981D 3/05
Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05
21