HP Hewlett Packard Switch 3500yl Series User Manual

ProCurve Switch 5400zl/3500yl Series  
The ProCurve Switch 5400zl/3500yl series consists of the most  
advanced intelligent edge switches in the ProCurve Networking product  
line. The 5400zl series includes 6-slot and 12-slot chassis and  
associated zl modules and bundles, and the 3500yl series includes  
24-port and 48-port stackables. The foundation for all these switches  
is a purpose-built, programmable ProVision ASIC that allows the most  
demanding networking features, such as QoS and security, to be  
implemented in a scalable yet granular fashion. With a variety of Gigabit  
interfaces, integrated PoE on all 10/100/1000Base-T ports, 10-GbE  
capability, and a choice of form factors, the 5400zl/3500yl switches  
offer excellent investment protection, flexibility, and scalability, as well  
as ease of deployment, operation, and maintenance.  
ProCurve Switch 5406zl  
Intelligent Edge (J8697A)  
ProCurve Switch 5406zl-48G  
Intelligent Edge (J8699A)  
ProCurve Switch 5412zl  
Intelligent Edge (J8698A)  
ProCurve Switch 5412zl-96G  
Intelligent Edge (J8700A)  
ProCurve Switch  
3500yl-24G-PWR  
ProCurve Switch  
3500yl-48G-PWR  
Intelligent Edge (J8692A)  
Intelligent Edge (J8693A)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Selectable queue configurations: increase  
performance by selecting the number of  
queues and associated memory buffering that  
best meet the requirements of your network  
applications  
ProCurve switch meshing: dynamically load-  
balances across multiple active redundant links  
to increase available aggregate bandwidth  
VLAN support and tagging: supports the  
IEEE 802.1Q standard and 2,048 VLANs  
simultaneously  
Resiliency and high availability  
Virtual Router Redundancy Protocol (requires  
Premium License): VRRP allows groups of two  
routers to dynamically back each other up to  
create highly available routed environments  
IEEE 802.1v protocol VLANs: isolate select  
non-IPv4 protocols automatically into their  
own VLANs  
GARP VLAN Registration Protocol: allows  
automatic learning and dynamic assignment  
of VLANs  
IEEE 802.1s Multiple Spanning Tree Protocol:  
provides high link availability in multiple  
VLAN environments by allowing multiple  
spanning trees; encompasses IEEE 802.1D  
Spanning Tree Protocol and IEEE 802.1w Rapid  
Spanning Tree Protocol  
Layer 3 services  
UDP helper function: UDP broadcasts can be  
directed across router interfaces to specific IP  
unicast or subnet broadcast addresses and  
prevent server spoofing for UDP services such  
as DHCP  
IEEE 802.3ad Link Aggregation Control  
Protocol (LACP) and ProCurve trunking:  
support up to 36 trunks, each with up to 8 links  
(ports) per trunk; trunking across modules is  
supported  
Loopback interface address: defines an  
address in RIP and OSPF that can always be  
reachable, improving diagnostic capability  
Hot-swappable modules (5400zl series):  
permits modules, mini-GBICs, and power  
supplies in a redundant power supply  
configuration to be added or swapped without  
interrupting the network  
Layer 3 routing  
Static IP routing: provides manually  
configured routing  
RIP: provides RIPv1 and RIPv2 routing at media  
Optional redundant power supply (5400zl  
series): provides uninterrupted power and  
allows hot-swapping of the redundant power  
supplies when installed  
speed  
OSPF (requires Premium License): includes  
host-based ECMP to provide link  
redundancy/scalable bandwidth and NSSA  
Sparing simplicity: ProCurve zl-common  
accessories (interface modules, power supplies)  
Security  
Layer 2 switching  
NEW  
USB Secure Autorun* (requires ProCurve  
Manager Plus): deploys, diagnoses, and  
updates switch using USB flash drive; works  
with secure credential to prevent tampering  
NEW  
IEEE 802.1ad Q-in-Q (requires Premium  
License): increases the scalability of Ethernet  
network by providing a hierarchical structure;  
connects multiple LANs on high-speed campus  
or metro network  
Switch CPU protection: provides automatic  
protection against malicious network traffic  
trying to shut down the switch  
Availability targeted for the second quarter of 2008.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Identity-driven ACL: enables implementation  
Features and benefits  
(continued)  
of a highly granular and flexible access security  
policy specific to each authenticated network  
user  
Virus throttling: detects traffic patterns typical  
of WORM-type viruses and either throttles or  
entirely prevents the ability of the virus to  
spread across the routed VLANs or bridged  
interfaces, without requiring external  
appliances  
DHCP protection: blocks DHCP packets from  
unauthorized DHCP servers, preventing denial-  
of-service attacks  
BPDU port protection: blocks Bridge Protocol  
Data Units (BPDU) on ports that do not require  
BPDUs, preventing forged BPDU attacks  
ICMP throttling: defeats ICMP denial-of-  
service attacks by enabling any switch port to  
automatically throttle ICMP traffic  
Dynamic IP lockdown: works with DHCP  
protection to block traffic from unauthorized  
host, preventing IP source address spoofing  
Multiple user authentication methods:  
IEEE 802.1X: industry-standard way of user  
authentication using an IEEE 802.1X  
supplicant on the client in conjunction with a  
RADIUS server  
Dynamic ARP protection: blocks ARP  
broadcasts from unauthorized hosts,  
preventing eavesdropping or theft of network  
data  
Web-based authentication: authenticates  
from Web browser for clients that do not  
support 802.1X supplicant; customized  
remediation can be processed on an external  
Web server  
NEW  
STP Root Guard: protects root bridge from  
malicious attack or configuration mistakes  
Detection of malicious attacks: monitors 10  
types of network traffic and sends a warning  
when an anomaly that potentially can be  
caused by malicious attacks is detected  
MAC-based authentication: client is  
authenticated with the RADIUS server based  
on client’s MAC address  
Port security: allows access only to specified  
MAC addresses, which can be learned or  
specified by the administrator  
Authentication flexibility:  
Multiple IEEE 802.1X users per port:  
provides authentication of multiple IEEE  
802.1X users per port; prevents user  
“piggybacking” on another user’s IEEE 802.1X  
authentication  
MAC address lockout: prevents configured  
particular MAC addresses from connecting to  
the network  
Source-port filtering: allows only specified  
ports to communicate with each other  
Concurrent IEEE 802.1X and Web or MAC  
authentication schemes per port: switch  
port will accept any of IEEE 802.1X and either  
Web or MAC authentications  
TACACS+: eases switch management security  
administration by using a password  
authentication server  
Access control lists (ACLs): provide filtering  
based on the IP field, source/destination IP  
address/subnet, and source/destination  
TCP/UDP port number on a per-VLAN or per-  
port basis  
Secure Shell (SSHv2): encrypts all transmitted  
data for secure, remote command-line  
interface (CLI) access over IP networks  
Secure Sockets Layer (SSL): encrypts all HTTP  
traffic, allowing secure access to the browser-  
based management GUI in the switch  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Secure FTP: allows secure file transfer to/from  
the switch; protects against unwanted file  
downloads or unauthorized copying of switch  
configuration file  
Bandwidth shaping:  
Port-based rate limiting: per-port  
ingress/egress enforced maximum  
bandwidth  
Secure management access: all access  
methods—CLI, GUI, or MIB—are securely  
encrypted through SSHv2, SSL, and/or SNMPv3  
Classified-based rate limiting: use ACL to  
enforce maximum bandwidth for ingress  
traffic on each port  
Switch management logon security:  
can require either RADIUS or TACACS+  
authentication for secure switch CLI logon  
Guaranteed minimum: per-port, per-queue  
egress-based guaranteed minimum  
bandwidth  
Security banner: displays a customized  
Class of Service (CoS): sets the IEEE 802.1p  
priority tag based on IP address, IP Type of  
Service (ToS), L3 protocol, TCP/UDP port  
number, source port, and DiffServ  
security policy when users log in to the switch  
Convergence  
IP multicast routing (Premium License):  
includes PIM Sparse and Dense modes to route  
IP multicast traffic  
Services  
ProCurve Switch 3500yl-24G-PWR Intelligent  
Edge  
IP multicast snooping (data-driven IGMP):  
automatically prevents flooding of IP multicast  
traffic  
• 3-year, 4-hour onsite, 13x5 coverage for  
hardware (U2855E)  
LLDP-MED (Media Endpoint Discovery):  
a standard extension of LLDP that stores values  
for parameters such as QoS and VLAN to  
automatically configure network devices such  
as IP phones  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware (U2856E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware, 24x7 software phone support  
(U6304E)  
NEW  
RADIUS VLAN for voice: uses standard  
RADIUS attribute and LLDP to automatically  
configure VLAN for IP phones  
• 3-year, 24x7 software phone support, software  
updates (UE262E)  
NEW  
PoE allocations: supports multiple methods  
(automatic, 802.3af class, LLDP-MED, or user  
specified) to allocate PoE power for optimal  
energy saving  
• Installation with minimum configuration,  
system-based pricing (U4826E)  
• Installation with HP-provided configuration,  
system-based pricing (U4830E)  
Quality of Service (QoS)  
Layer 4 prioritization: enables prioritization  
based on TCP/UDP port numbers  
Traffic prioritization: allows real-time traffic  
classification into 8 priority levels mapped to  
8 queues  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
• 3-year, 4-hour onsite, 24x7 coverage for  
Services (continued)  
hardware, 24x7 software phone support  
(UE252E)  
ProCurve Switch 3500yl-48G-PWR Intelligent  
Edge  
• 3-year, 24x7 software phone support, software  
updates (UF786E)  
• 3-year, 4-hour onsite, 13x5 coverage for  
hardware (H4496E)  
• Installation with minimum configuration,  
system-based pricing (U4828E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware (H2893E)  
• Installation with HP-provided configuration,  
system-based pricing (U4832E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware, 24x7 software phone support  
(U6319E)  
ProCurve Switch 5412zl Intelligent Edge  
ProCurve Switch 5412zl-96G Intelligent Edge  
• 3-year, 24x7 software phone support, software  
updates (UE264E)  
• 3-year, 4-hour onsite, 13x5 coverage for  
hardware (UE253E)  
• Installation with minimum configuration,  
system-based pricing (U4826E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware (UE254E)  
• Installation with HP-provided configuration,  
system-based pricing (U4830E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware, 24x7 software phone support  
(UE255E)  
ProCurve Switch 5406zl Intelligent Edge  
ProCurve Switch 5406zl-48G Intelligent Edge  
• 3-year, 24x7 software phone support, software  
updates (UF788E)  
• 3-year, 4-hour onsite, 13x5 coverage for  
hardware (UE250E)  
• Installation with minimum configuration,  
system-based pricing (U4828E)  
• 3-year, 4-hour onsite, 13x5 coverage for  
hardware (H4496E)  
• Installation with HP-provided configuration,  
system-based pricing (U4832E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware (UE251E)  
Check www.procurve.eu/services for part  
numbers and service-level descriptions.  
For details about services and response times in  
your area, please contact your local HP sales  
office.  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware (H2893E)  
• 3-year, 4-hour onsite, 24x7 coverage for  
hardware, 24x7 software phone support  
(U6319E)  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
ProCurve Switch 5406zl Intelligent Edge (J8697A)  
ProCurve Switch 5406zl-48G Intelligent Edge (J8699A)  
Included accessories  
Ports  
N/A  
2 ProCurve Switch zl 24-Port 10/100/1000 PoE Modules (J8702A)  
1 ProCurve Switch zl 875W Power Supply (J8712A)  
6 open module slots  
4 open module slots  
48 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE  
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T) with PoE  
Media type: IEEE Auto-MDIX  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
1 RS-232C DB-9 console port  
1 RS-232C DB-9 console port  
Supports a maximum of 144 auto-sensing 10/100/1000 ports or  
24 10-GbE ports or 144 mini-GBICs, or a combination  
Supports a maximum of 144 auto-sensing 10/100/1000 ports with PoE or  
16 10-GbE ports or 96 mini-GBICs, or a combination  
Power supplies  
2 open power-supply slots  
Includes 1 x J8712A  
1 open power-supply slot  
Physical characteristics  
Dimensions (D x W x H)  
Weight  
45.09 x 44.45 x 17.53 cm (17.75 x 17.5 x 6.9 in.) (4U height)  
10.68 kg (23.55 lb.)  
45.09 x 44.45 x 17.53 cm (17.75 x 17.5 x 6.9 in.) (4U height)  
15.54 kg (34.26 lb.)  
Memory and processor  
Gigabit module  
10G module  
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM  
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB  
compact flash, 256 MB DDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM  
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash,  
256 MB DDR SDRAM  
Management module  
Mounting  
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only  
Performance  
Latency  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 214 million pps  
288 Gbps  
346 Gbps  
10,000 entries  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 214 million pps  
288 Gbps  
346 Gbps  
10,000 entries  
1000 Mb  
10 Gbps  
Throughput  
Routing/Switching capacity  
Switch fabric speed  
Routing table size  
Environment  
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or  
J8707A modules installed  
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or  
J8707A modules installed  
Operating temperature  
15% to 95% @ 55°C (131°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 95% @ 65°C (149°F), non-condensing  
15% to 95% @ 55°C (131°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 95% @ 65°C (149°F), non-condensing  
Operating relative humidity  
Non-operating/Storage temperature  
Non-operating/Storage  
relative humidity  
Up to 4.6 km (15,000 ft.)  
Power: 57 dB; pressure: 40.2 dB  
ISO 7779, ISO 9296  
Up to 4.6 km (15,000 ft.)  
Power: 57 dB; pressure: 40.2 dB  
ISO 7779, ISO 9296  
Altitude  
Acoustic  
Electrical characteristics  
Chassis ships without power supplies. Two power-supply slots available;  
two different power supplies available. See power-supply products for  
additional specifications.  
One J8712A installed. One open power-supply slot available; two different  
power supplies available. See power-supply products for additional  
specifications.  
Description  
2,584 kJ/hr (2,450 BTU/hr) (max non-PoE)  
3,903 kJ/hr (3,700 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
2,584 kJ/hr (2,450 BTU/hr) (max non-PoE)  
3,903 kJ/hr (3,700 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
Maximum heat dissipation  
Voltage  
Frequency  
Notes  
50/60 Hz  
50/60 Hz  
Power supplies must be ordered separately. One J8712A or J8713A can  
power the J8697A chassis.  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Safety  
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950  
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A  
Emissions  
Immunity  
EN 55024, CISPR 24  
EN 55024, CISPR 24  
EN  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
ESD  
Radiated  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
EFT/Burst  
Surge  
IEC 61000-4-6; 3 V  
IEC 61000-4-6; 3 V  
Conducted  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods  
EN 61000-3-2, IEC 61000-3-2  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods  
EN 61000-3-2, IEC 61000-3-2  
Power frequency magnetic field  
Voltage dips and interruptions  
Harmonics  
EN 61000-3-3, IEC 61000-3-3  
EN 61000-3-3, IEC 61000-3-3  
Flicker  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
(continued)  
ProCurve Switch 5406zl Intelligent Edge (J8697A)  
ProCurve Switch 5406zl-48G Intelligent Edge (J8699A)  
Management  
Notes  
ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management  
(serial RS-232C)  
When using mini-GBICs with this product, mini-GBICs with revision “B” or later (product number ends with the letter “B” or later, e.g., J4858B, J4859C)  
are required.  
Standards and protocols  
(applies to both products)  
Device management  
RFC 1591 DNS (client)  
HTML and telnet management  
IP multicast  
RFC 2665 Ethernet-Like-MIB  
RFC 2668 802.3 MAU MIB  
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB  
RFC 2737 Entity MIB (Version 2)  
RFC 2787 VRRP MIB  
RFC 2362 PIM Sparse Mode (Premium License)  
RFC 3376 IGMPv3 (host joins only)  
RFC 3973 PIM Dense Mode (Premium License)  
General protocols  
IEEE 802.1ad Q-in-Q (Premium License)  
IEEE 802.1D MAC Bridges  
IEEE 802.1p Priority  
IPv6  
RFC 2863 The Interfaces Group MIB  
RFC 2925 Ping MIB  
RFC 1981 IPv6 Path MTU Discovery  
RFC 2460 IPv6 Specification  
RFC 2461 IPv6 Neighbor Discovery  
RFC 2462 IPv6 Stateless Address  
Auto-configuration  
RFC 2463 ICMPv6  
RFC 2710 Multicast Listener Discovery (MLD)  
for IPv6  
IEEE 802.1Q VLANs  
Network management  
IEEE 802.1AB Link Layer Discovery Protocol  
(LLDP)  
RFC 2819 Four groups of RMON: 1 (statistics),  
2 (history), 3 (alarm), and 9 (events)  
RFC 3176 sFlow  
IEEE 802.1s Multiple Spanning Trees  
IEEE 802.1v VLAN classification by Protocol and  
Port  
IEEE 802.1w Rapid Reconfiguration of Spanning  
Tree  
IEEE 802.3ad Link Aggregation Control Protocol  
(LACP)  
RFC 2925 Remote Operations MIB (Ping only)  
RFC 3019 MLDv1 MIB  
ANSI/TIA-1057 LLDP Media Endpoint Discovery  
(LLDP-MED)  
IEEE 802.3af Power over Ethernet  
IEEE 802.3x Flow Control  
RFC 768 UDP  
RFC 783 TFTP Protocol (revision 2)  
RFC 792 ICMP  
RFC 3315 DHCPv6 (client only)  
RFC 3513 IPv6 Addressing Architecture  
RFC 3596 DNS Extension for IPv6  
RFC 3810 MLDv2 (host joins only)  
RFC 4022 MIB for TCP  
SNMPv1/v2c/v3  
XRMON  
OSPF  
RFC 2328 OSPFv2 (Premium License)  
RFC 3101 OSPF NSSA  
RFC 793 TCP  
RFC 4113 MIB for UDP  
RFC 826 ARP  
RFC 854 TELNET  
RFC 868 Time Protocol  
RFC 951 BOOTP  
RFC 4251 SSHv6 Architecture  
RFC 4252 SSHv6 Authentication  
RFC 4253 SSHv6 Transport Layer  
RFC 4254 SSHv6 Connection  
RFC 4293 MIB for IP  
QoS/Cos  
RFC 2474 DiffServ Precedence, including  
8 queues/port  
RFC 1058 RIPv1  
RFC 2597 DiffServ Assured Forwarding (AF)  
RFC 2598 DiffServ Expedited Forwarding (EF)  
RFC 1350 TFTP Protocol (revision 2)  
RFC 1519 CIDR  
RFC 4419 Key Exchange for SSH  
RFC 4541 IGMP & MLD Snooping Switch  
RFC 1542 BOOTP Extensions  
RFC 2030 Simple Network Time Protocol (SNTP)  
v4  
Security  
MIBs  
RFC 1213 MIB II  
IEEE 802.1X Port Based Network Access Control  
RFC 1492 TACACS+  
RFC 2131 DHCP  
RFC 2453 RIPv2  
RFC 1493 Bridge MIB  
RFC 1724 RIPv2 MIB  
RFC 2865 RADIUS (client only)  
RFC 2866 RADIUS Accounting  
Secure Sockets Layer (SSL)  
SSHv1/SSHv2 Secure Shell  
RFC 2548 (MS-RAS-Vendor only)  
RFC 3046 DHCP Relay Agent Information Option  
RFC 3576 Ext to RADIUS (CoA only)  
RFC 3768 VRRP (Premium License)  
RFC 4675 RADIUS VLAN & Priority  
UDLD (Uni-directional Link Detection)  
RFC 1850 OSPFv2 MIB  
RFC 2021 RMONv2 MIB  
RFC 2096 IP Forwarding Table MIB  
RFC 2613 SMON MIB  
RFC 2618 RADIUS Client MIB  
RFC 2620 RADIUS Accounting MIB  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
ProCurve Switch 5412zl Intelligent Edge (J8698A)  
ProCurve Switch 5412zl-96G Intelligent Edge (J8700A)  
Included accessories  
Ports  
N/A  
4 ProCurve Switch zl 24-Port 10/100/1000 PoE Modules (J8702A)  
2 ProCurve Switch zl 875W Power Supplies (J8712A)  
12 open module slots  
8 open module slots  
96 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE  
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T) with PoE  
Media type: IEEE Auto-MDIX  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
1 RS-232C DB-9 console port  
1 RS-232C DB-9 console port  
Supports a maximum of 288 auto-sensing 10/100/1000 ports or  
48 10-GbE ports or 288 mini-GBICs, or a combination  
Supports a maximum of 288 auto-sensing 10/100/1000 ports with PoE or  
32 10-GbE ports or 192 mini-GBICs, or a combination  
4 open power-supply slots  
Power supplies  
Includes 2 x J8712A  
2 open power-supply slots  
Physical characteristics  
Dimensions (D x W x H)  
Weight  
45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)  
15.85 kg (34.94 lb.)  
45.09 x 44.45 x 30.73 cm (17.75 x 17.5 x 12.1 in.) (7U height)  
26.31 kg (58 lb.)  
Memory and processor  
Gigabit module  
10G module  
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM  
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact  
flash, 256 MB DDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM  
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash,  
256 MB DDR SDRAM  
Management module  
Mounting  
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only  
Performance  
Latency  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 428 million pps  
576 Gbps  
692 Gbps  
10,000 entries  
1000 Mb  
10 Gbps  
Throughput  
Routing/Switching capacity  
Switch fabric speed  
Routing table size  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 428 million pps  
576 Gbps  
692 Gbps  
10,000 entries  
Environment  
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or  
J8707A modules installed  
Operating temperature  
0°C to 55°C (32°F to 131°F); 0°C to 40°C with J8705A, J8706A, or  
J8707A modules installed  
15% to 95% @ 55°C (131°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 95% @ 65°C (149°F), non-condensing  
Operating relative humidity  
Non-operating/Storage temperature  
Non-operating/Storage  
relative humidity  
15% to 95% @ 55°C (131°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 95% @ 65°C (149°F), non-condensing  
Up to 4.6 km (15,000 ft.)  
Power: 64 dB; pressure: 57.5 dB  
ISO 7779, ISO 9296  
Altitude  
Acoustic  
Up to 4.6 km. (15,000 ft)  
Power: 64 dB; pressure: 57.5 dB  
ISO 7779, ISO 9296  
Electrical characteristics  
Chassis ships without power supplies. Four power-supply slots  
available; two different power supplies available. See power-supply  
products for additional specifications.  
Description  
Two J8712A installed. Two open power-supply slots available; two different  
power supplies available. See power-supply products for additional  
specifications.  
5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)  
7,807 kJ/hr (7,400 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
Maximum heat dissipation  
5,169 kJ/hr (4,900 BTU/hr) (max non-PoE)  
7,807 kJ/hr (7,400 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
Voltage  
Frequency  
Notes  
50/60 Hz  
50/60 Hz  
Power supplies must be ordered separately. A combination of two  
power supplies either J8712A or J8713A is required to power the  
J8698A chassis.  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Safety  
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950  
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A  
Emissions  
Immunity  
EN 55024, CISPR 24  
EN  
EN 55024, CISPR 24  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
ESD  
Radiated  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
IEC 61000-4-6; 3 V  
EFT/Burst  
Surge  
Conducted  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
IEC 61000-4-6; 3 V  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,  
25 periods  
Power frequency magnetic field  
Voltage dips and interruptions  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction,  
25 periods  
EN 61000-3-2, IEC 61000-3-2  
EN 61000-3-3, IEC 61000-3-3  
Harmonics  
Flicker  
EN 61000-3-2, IEC 61000-3-2  
EN 61000-3-3, IEC 61000-3-3  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
(continued)  
ProCurve Switch 5412zl Intelligent Edge (J8698A)  
ProCurve Switch 5412zl-96G Intelligent Edge (J8700A)  
Management  
Notes  
ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management  
(serial RS-232C)  
When using mini-GBICs with this product, mini-GBICs with revision “B” or later (product number ends with the letter “B” or later, e.g., J4858B, J4859C)  
are required.  
Standards and protocols  
(applies to both products)  
Device management  
RFC 1591 DNS (client)  
HTML and telnet management  
IP multicast  
RFC 2665 Ethernet-Like-MIB  
RFC 2668 802.3 MAU MIB  
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB  
RFC 2737 Entity MIB (Version 2)  
RFC 2787 VRRP MIB  
RFC 2362 PIM Sparse Mode (Premium License)  
RFC 3376 IGMPv3 (host joins only)  
RFC 3973 PIM Dense Mode (Premium License)  
General protocols  
IEEE 802.1ad Q-in-Q (Premium License)  
IEEE 802.1D MAC Bridges  
IEEE 802.1p Priority  
IPv6  
RFC 2863 The Interfaces Group MIB  
RFC 2925 Ping MIB  
RFC 1981 IPv6 Path MTU Discovery  
RFC 2460 IPv6 Specification  
RFC 2461 IPv6 Neighbor Discovery  
RFC 2462 IPv6 Stateless Address  
Auto-configuration  
RFC 2463 ICMPv6  
RFC 2710 Multicast Listener Discovery (MLD)  
for IPv6  
IEEE 802.1Q VLANs  
Network management  
IEEE 802.1AB Link Layer Discovery Protocol  
(LLDP)  
RFC 2819 Four groups of RMON: 1 (statistics),  
2 (history), 3 (alarm), and 9 (events)  
RFC 3176 sFlow  
IEEE 802.1s Multiple Spanning Trees  
IEEE 802.1v VLAN classification by Protocol and  
Port  
IEEE 802.1w Rapid Reconfiguration of Spanning  
Tree  
IEEE 802.3ad Link Aggregation Control Protocol  
(LACP)  
RFC 2925 Remote Operations MIB (Ping only)  
RFC 3019 MLDv1 MIB  
ANSI/TIA-1057 LLDP Media Endpoint Discovery  
(LLDP-MED)  
IEEE 802.3af Power over Ethernet  
IEEE 802.3x Flow Control  
RFC 768 UDP  
RFC 783 TFTP Protocol (revision 2)  
RFC 792 ICMP  
RFC 3315 DHCPv6 (client only)  
RFC 3513 IPv6 Addressing Architecture  
RFC 3596 DNS Extension for IPv6  
RFC 3810 MLDv2 (host joins only)  
RFC 4022 MIB for TCP  
SNMPv1/v2c/v3  
XRMON  
OSPF  
RFC 2328 OSPFv2 (Premium License)  
RFC 3101 OSPF NSSA  
RFC 793 TCP  
RFC 4113 MIB for UDP  
RFC 826 ARP  
RFC 854 TELNET  
RFC 868 Time Protocol  
RFC 951 BOOTP  
RFC 4251 SSHv6 Architecture  
RFC 4252 SSHv6 Authentication  
RFC 4253 SSHv6 Transport Layer  
RFC 4254 SSHv6 Connection  
RFC 4293 MIB for IP  
QoS/Cos  
RFC 2474 DiffServ Precedence, including  
8 queues/port  
RFC 1058 RIPv1  
RFC 2597 DiffServ Assured Forwarding (AF)  
RFC 2598 DiffServ Expedited Forwarding (EF)  
RFC 1350 TFTP Protocol (revision 2)  
RFC 1519 CIDR  
RFC 4419 Key Exchange for SSH  
RFC 4541 IGMP & MLD Snooping Switch  
RFC 1542 BOOTP Extensions  
RFC 2030 Simple Network Time Protocol (SNTP)  
v4  
Security  
MIBs  
RFC 1213 MIB II  
IEEE 802.1X Port Based Network Access Control  
RFC 1492 TACACS+  
RFC 2131 DHCP  
RFC 2453 RIPv2  
RFC 1493 Bridge MIB  
RFC 1724 RIPv2 MIB  
RFC 2865 RADIUS (client only)  
RFC 2866 RADIUS Accounting  
Secure Sockets Layer (SSL)  
SSHv1/SSHv2 Secure Shell  
RFC 2548 (MS-RAS-Vendor only)  
RFC 3046 DHCP Relay Agent Information Option  
RFC 3576 Ext to RADIUS (CoA only)  
RFC 3768 VRRP (Premium License)  
RFC 4675 RADIUS VLAN & Priority  
UDLD (Uni-directional Link Detection)  
RFC 1850 OSPFv2 MIB  
RFC 2021 RMONv2 MIB  
RFC 2096 IP Forwarding Table MIB  
RFC 2613 SMON MIB  
RFC 2618 RADIUS Client MIB  
RFC 2620 RADIUS Accounting MIB  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
ProCurve Switch 3500yl-24G-PWR Intelligent Edge (J8692A)  
ProCurve Switch 3500yl-48G-PWR Intelligent Edge (J8693A)  
Ports  
1 open module slot  
1 open module slot  
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE  
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)  
Media type: Auto-MDIX  
44 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE  
802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T)  
Media type: Auto-MDIX  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
1 RS-232C DB-9 console port  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
1 RS-232C DB-9 console port  
4 dual-personality ports—each port can be used as either an RJ-45  
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type  
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or  
an open mini-GBIC slot (for use with mini-GBIC transceivers)  
Supports a maximum of 4 10-GbE ports  
4 dual-personality ports—each port can be used as either an RJ-45  
10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type  
100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) with PoE or an  
open mini-GBIC slot (for use with mini-GBIC transceivers)  
Supports a maximum of 4 10-GbE ports  
Physical characteristics  
Dimensions (D x W x H)  
Weight  
39.2 x 44.3 x 4.4 cm (15.43 x 17.44 x 1.73 in.) (1U height)  
6.4 kg (14.11 lb.)  
43.0 x 44.3 x 4.4 cm (16.93 x 17.44 x 1.73 in.) (1U height)  
7.3 kg (16.09 lb.)  
Memory and processor  
10G module  
Management module  
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM  
Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz,  
4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM  
ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM  
Stackable memory and processor: Freescale PowerPC 8540 @ 666 MHz,  
4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM  
Mounting  
Mounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only  
Performance  
Latency  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 74 million pps  
101 Gbps  
115 Gbps  
10,000 entries  
<3.7 µs (FIFO 64-byte packets)  
<2.1 µs (FIFO 64-byte packets)  
Up to 110 million pps  
148 Gbps  
173 Gbps  
10,000 entries  
1000 Mb  
10 Gbps  
Throughput  
Routing/Switching capacity  
Switch fabric speed  
Routing table size  
Environment  
0° to 55°C (32°F to 131°F); 32°F to 40°C (104°F) when used with  
any X2 10-GbE  
0° to 55°C (32°F to 131°F); 32°F to 40°C (104°F) when used with  
any X2 10-GbE  
Operating temperature  
15% to 95% at 40°C (104°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 90% at 65°C (149°F), non-condensing  
15% to 95% at 40°C (104°F), non-condensing  
–40°C to 70°C (–40°F to 158°F)  
15% to 95% at 65°C (149°F), non-condensing  
Operating relative humidity  
Non-operating/Storage temperature  
Non-operating/Storage  
relative humidity  
Up to 4.6 km (15,000 ft.)  
Power: 52.7 dB; pressure: 44.8 dB  
ISO 7779, ISO 9296  
Up to 4.6 km (15,000 ft.)  
Power: 55.1 dB; pressure: 45.3 dB  
ISO 7779, ISO 9296  
Altitude  
Acoustic  
Electrical characteristics  
The switch automatically adjusts to any voltage between 100–127 and  
200–240 volts and either 50 or 60 Hz  
706 kJ/hr (670 BTU/hr) (max non-PoE)  
991 kJ/hr (940 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
The switch automatically adjusts to any voltage between 100–127 and  
200–240 volts and either 50 or 60 Hz  
854 kJ/hr (810 BTU/hr) (max non-PoE)  
1,149 kJ/hr (1,090 BTU/hr) (max using PoE)  
100–127 VAC/200–240 VAC  
Description  
Maximum heat dissipation  
Voltage  
10.0 A/5.0 A  
10.0 A/5.0 A  
Current  
723 W  
50/60 Hz  
759 W  
50/60 Hz  
Power consumption  
Frequency  
Notes  
Maximum power draw if not using any PoE power is 200 W  
(1.8 A @ 110 V, 0.9 A @ 220V); full load switch only heat spec listed  
above subtracts heat dissipated in external PoE powered devices.  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Maximum power draw if not using any PoE power is 200 W  
(1.8 A @ 110 V, 0.9 A @ 220V).  
Heat dissipation does not include heat dissipated by the PoE powered  
devices themselves.  
Safety  
CSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950  
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A  
Emissions  
Immunity  
EN 55024, CISPR 24  
EN 55024, CISPR 24  
EN  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
IEC 61000-4-2; 4 kV CD, 8 kV AD  
IEC 61000-4-3; 3 V/m  
ESD  
Radiated  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)  
IEC 61000-4-5; 1 kV/2 kV AC  
EFT/Burst  
Surge  
IEC 61000-4-6; 3 V  
IEC 61000-4-6; 3 V  
Conducted  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods  
EN 61000-3-2, IEC 61000-3-2  
IEC 61000-4-8; 1 A/m, 50 or 60 Hz  
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods  
EN 61000-3-2, IEC 61000-3-2  
Power frequency magnetic field  
Voltage dips and interruptions  
Harmonics  
EN 61000-3-3, IEC 61000-3-3  
EN 61000-3-3, IEC 61000-3-3  
Flicker  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series  
Specifications  
(continued)  
ProCurve Switch 3500yl-24G-PWR Intelligent Edge (J8692A)  
ProCurve Switch 3500yl-48G-PWR Intelligent Edge (J8693A)  
Management  
Notes  
ProCurve Manager Plus; ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management  
(serial RS-232C)  
When using mini-GBICs with this product, mini-GBICs with revision “B” or later (product number ends with the letter “B” or later, e.g., J4858B, J4859C)  
are required.  
J8177B Gigabit 1000Base-T mini-GBIC is not supported on the 3500yl series switches.  
Device management  
RFC 1591 DNS (client)  
HTML and telnet management  
IP multicast  
RFC 2665 Ethernet-Like-MIB  
RFC 2668 802.3 MAU MIB  
RFC 2674 802.1p and IEEE 802.1Q Bridge MIB  
RFC 2737 Entity MIB (Version 2)  
RFC 2787 VRRP MIB  
Standards and protocols  
(applies to both products)  
RFC 2362 PIM Sparse Mode (Premium License)  
RFC 3376 IGMPv3 (host joins only)  
RFC 3973 PIM Dense Mode (Premium License)  
General protocols  
IEEE 802.1ad Q-in-Q (Premium License)  
IEEE 802.1D MAC Bridges  
IEEE 802.1p Priority  
IPv6  
RFC 2863 The Interfaces Group MIB  
RFC 2925 Ping MIB  
RFC 1981 IPv6 Path MTU Discovery  
RFC 2460 IPv6 Specification  
RFC 2461 IPv6 Neighbor Discovery  
RFC 2462 IPv6 Stateless Address  
Auto-configuration  
RFC 2463 ICMPv6  
RFC 2710 Multicast Listener Discovery (MLD)  
for IPv6  
IEEE 802.1Q VLANs  
Network management  
IEEE 802.1AB Link Layer Discovery Protocol  
(LLDP)  
RFC 2819 Four groups of RMON: 1 (statistics),  
2 (history), 3 (alarm), and 9 (events)  
RFC 3176 sFlow  
IEEE 802.1s Multiple Spanning Trees  
IEEE 802.1v VLAN classification by Protocol and  
Port  
IEEE 802.1w Rapid Reconfiguration of Spanning  
Tree  
IEEE 802.3ad Link Aggregation Control Protocol  
(LACP)  
RFC 2925 Remote Operations MIB (Ping only)  
RFC 3019 MLDv1 MIB  
ANSI/TIA-1057 LLDP Media Endpoint Discovery  
(LLDP-MED)  
IEEE 802.3af Power over Ethernet  
IEEE 802.3x Flow Control  
RFC 768 UDP  
RFC 783 TFTP Protocol (revision 2)  
RFC 792 ICMP  
RFC 3315 DHCPv6 (client only)  
RFC 3513 IPv6 Addressing Architecture  
RFC 3596 DNS Extension for IPv6  
RFC 3810 MLDv2 (host joins only)  
RFC 4022 MIB for TCP  
SNMPv1/v2c/v3  
XRMON  
OSPF  
RFC 2328 OSPFv2 (Premium License)  
RFC 3101 OSPF NSSA  
RFC 793 TCP  
RFC 4113 MIB for UDP  
RFC 826 ARP  
RFC 854 TELNET  
RFC 868 Time Protocol  
RFC 951 BOOTP  
RFC 4251 SSHv6 Architecture  
RFC 4252 SSHv6 Authentication  
RFC 4253 SSHv6 Transport Layer  
RFC 4254 SSHv6 Connection  
RFC 4293 MIB for IP  
QoS/Cos  
RFC 2474 DiffServ Precedence, including  
8 queues/port  
RFC 1058 RIPv1  
RFC 2597 DiffServ Assured Forwarding (AF)  
RFC 2598 DiffServ Expedited Forwarding (EF)  
RFC 1350 TFTP Protocol (revision 2)  
RFC 1519 CIDR  
RFC 4419 Key Exchange for SSH  
RFC 4541 IGMP & MLD Snooping Switch  
RFC 1542 BOOTP Extensions  
RFC 2030 Simple Network Time Protocol (SNTP)  
v4  
Security  
MIBs  
RFC 1213 MIB II  
IEEE 802.1X Port Based Network Access Control  
RFC 1492 TACACS+  
RFC 2131 DHCP  
RFC 2453 RIPv2  
RFC 1493 Bridge MIB  
RFC 1724 RIPv2 MIB  
RFC 2865 RADIUS (client only)  
RFC 2866 RADIUS Accounting  
Secure Sockets Layer (SSL)  
SSHv1/SSHv2 Secure Shell  
RFC 2548 (MS-RAS-Vendor only)  
RFC 3046 DHCP Relay Agent Information Option  
RFC 3576 Ext to RADIUS (CoA only)  
RFC 3768 VRRP (Premium License)  
RFC 4675 RADIUS VLAN & Priority  
UDLD (Uni-directional Link Detection)  
RFC 1850 OSPFv2 MIB  
RFC 2021 RMONv2 MIB  
RFC 2096 IP Forwarding Table MIB  
RFC 2613 SMON MIB  
RFC 2618 RADIUS Client MIB  
RFC 2620 RADIUS Accounting MIB  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series Modules  
zl Modules  
ProCurve Switch zl 4-Port 10-GbE X2 Module  
(J8707A)  
ProCurve Switch zl 24-Port 10/100/1000 PoE Module  
(J8702A)  
4-port 10-GbE X2 module for zl series switches  
24-port 10/100/1000 PoE module for zl series switches  
Ports  
Ports  
4 open 10-GbE X2 transceiver slots  
24 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T;  
IEEE 802.3u Type 100Base-TX; IEEE 802.3ab Type 1000Base-T)  
Media type: IEEE Auto-MDI/MDIX  
Physical characteristics  
Dimensions (D x W x H): 26.16 x 20.65 x 4.45 cm  
(10.3 x 8.13 x 1.75 in.)  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
Weight: 0.79 kg (1.74 lb.)  
Physical characteristics  
Dimensions (D x W x H): 26.16 x 20.65 x 4.45 cm  
(10.3 x 8.13 x 1.75 in.)  
Environment  
Operating temperature: 0°C to 40°C (32°F to 104°F)  
Weight: 0.98 kg (2.16 lb.)  
Notes  
Cabling  
When installed in a zl chassis, the J8707A module limits the operating  
temperature range of the chassis to 0°C to 40°C (32°F to 104°F).  
Type:  
• 1000Base-T: Category 5 (5E or better recommended), 100 Ω differential  
4-pair unshielded twisted pair (UTP) or shielded twisted pair (STP)  
balanced, complying with IEEE 802.3ab 1000Base-T  
ProCurve Switch zl 20-Port 10/100/1000 + 4-Port  
Mini-GBIC Module (J8705A)  
ProCurve Switch zl 4-Port 10-GbE CX4 Module  
(J8708A)  
20-port 10/100/1000 PoE + 4-port mini-GBIC module for zl series  
4-port 10-GbE CX4 module for zl series switches  
switches  
Ports  
Ports  
4 CX-4 10-GbE ports (IEEE 802.3ak Type 10Gbase-CX4)  
Duplex: full only  
4 open mini-GBIC (SFP) slots  
20 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T;  
IEEE 802.3u type 100Base-TX; IEEE 802.3ab Type 1000Base-T)  
Media type: IEEE Auto-MDIX  
Physical characteristics  
Dimensions (D x W x H): 26.16 x 20.65 x 4.45 cm  
(10.3 x 8.13 x 1.75 in.)  
Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only  
Weight: 0.79 kg (1.74 lb.)  
Physical characteristics  
Dimensions (D x W x H): 26.16 x 20.65 x 4.45 cm  
(10.3 x 8.13 x 1.75 in.)  
Environment  
Operating temperature: 0°C to 55°C (32°F to 131°F)  
Weight: 1 kg (2.2 lb.)  
Cabling  
Notes  
Maximum distance:  
When using mini-GBICs with this product, mini-GBICs with revision “B” or  
later (product number ends with the letter “B” or later, e.g., J4858B,  
J4859C) are required.  
15 m using CX4 cable  
300 m using optical media converters and multimode fiber cable  
When installed in a zl chassis, the J8705A module limits the operating  
temperature range of the chassis to 0°C to 40°C (32°F to 104°F).  
Notes  
Use CX4 10-GbE cable (0.5 m–15 m) or ProCurve 10-GbE CX4 Media  
Converter (J8439A).  
No CX4 cables are included with this module.  
Services for accessories are covered under the product in which they are installed.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series Modules  
zl Modules (continued)  
yl Modules  
ProCurve Switch zl 24-Port Mini-GBIC Module  
(J8706A)  
ProCurve Switch yl 10-GbE 2-Port CX4 + 2-Port X2  
Module (J8694A)  
24-port mini-GBIC module for zl series switches  
10-GbE module with two fixed CX4 ports and two X2 slots for ProCurve  
Switch 3500yl series and Switch 6200yl-24G-mGBIC  
Ports  
24 open mini-GBIC (SFP) slots  
Ports  
2 open 10-GbE X2 transceiver slots  
2 10-GbE ports (IEEE 802.3ak Type 10Gbase-CX4)  
Duplex: full only  
Physical characteristics  
Dimensions (D x W x H): 26.16 x 20.65 x 4.45 cm  
(10.3 x 8.13 x 1.75 in.)  
Weight: 0.91 kg (2.01 lb.)  
Physical characteristics  
Dimensions (D x W x H): 19.7 x 19.1 x 36.3 cm (7.76 x 7.52 x 14.29 in.)  
Weight: 0.7 kg (1.54 lb.)  
Notes  
When using mini-GBICs with this product, mini-GBICs with revision “B” or  
later (product number ends with the letter “B” or later, e.g., J4858B,  
J4859C) are required.  
When installed in a zl chassis, the J8706A module limits the operating  
temperature range of the chassis to 0°C to 40°C (32°F to 104°F).  
Environment  
Operating temperature: 0°C to 55°C (32°F to 131°F)  
Operating relative humidity: 15% to 95%, non-condensing  
Non-operating/Storage temperature: –40°C to 70°C (–40°F to 158°F)  
Non-operating/Storage relative humidity: 15% to 90%, non-condensing  
Cabling  
Maximum distance:  
CX4: 15 m using CX4 cable or 300 m using media converter with ribbon MMF  
Notes  
Only the two fixed CX4 ports on this module support ProCurve 10-GbE CX4  
Media Converter (J8439A).  
Operating temperature is 0°C to 40°C (32°F to 104°F) if any X2 10-GbE  
optic or transceiver is inserted in any X2 slot.  
One 0.5 m CX4 cable is included.  
Licenses  
Premium License for Switch 3500 Series (J8993A)  
Premium License for Switch 5400 Series (J8994A)  
License to enable OSPFv2, PIM Dense mode, PIM Sparse mode, VRRP,  
and QinQ in the ProCurve 3500yl switch.  
License to enable OSPFv2, PIM Dense mode, PIM Sparse mode, VRRP,  
and QinQ in the ProCurve 5400zl switch.  
Notes  
Notes  
The following features are included in this license:  
The following features are included in this license:  
• OSPFv2  
• OSPFv2  
• PIM Dense mode  
• PIM Sparse mode  
• VRRP  
• PIM Dense mode  
• PIM Sparse mode  
• VRRP  
• QinQ (IEEE 802.1ad)  
• QinQ (IEEE 802.1ad)  
Services for accessories are covered under the product in which they are installed.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series Modules  
Power Supplies  
ProCurve Switch zl 1500W Power Supply (J8713A)  
High-power 1500 W power supply for zl series switches. Supplies 900 W  
for PoE power plus 600 W for switch power. 200–240 V only.  
ProCurve Switch zl 875W Power Supply (J8712A)  
Standard 875 W power supply for zl series switches. Supplies 273 W for  
PoE power plus 600 W for switch power.  
Physical characteristics  
Dimensions (D x W x H): 15.37 x 18.92 x 12.95 cm  
(6.05 x 7.45 x 5.1 in.)  
Physical characteristics  
Dimensions (D x W x H): 15.37 x 18.92 x 12.95 cm  
(6.05 x 7.45 x 5.1 in.)  
Weight: 3.4 kg (7.5 lb.)  
Weight: 3.2 kg (7.05 lb.)  
Environment  
Environment  
Operating temperature: 0°C to 55°C (32°F to 131°F)  
Operating relative humidity: 15% to 95%, non-condensing  
Non-operating/Storage temperature: –40°C to 70°C (–40°F to 158°F)  
Non-operating/Storage relative humidity: 15% to 95%, non-condensing  
Altitude: up to 3 km (10,000 ft.)  
Operating temperature: 0°C to 55°C (32°F to 131°F)  
Operating relative humidity: 15% to 95%, non-condensing  
Non-operating/Storage temperature: –40°C to 70°C (–40°F to 158°F)  
Non-operating/Storage relative humidity: 15% to 95%, non-condensing  
Altitude: up to 3 km (10,000 ft.)  
Electrical characteristics  
Voltage: 200–240 VAC  
Current: 10 A  
Electrical characteristics  
Voltage: 100–127 VAC/200–240 VAC  
Current: 12 A/5.7 A  
Frequency: 50/60 Hz  
Power consumption: 1800 W  
Frequency: 50/60 Hz  
Power consumption: 1050 W  
Notes  
Notes  
200–240 V only. Installation of the J8713A reduces the chassis altitude  
specification to 3677 m (10,000 ft.).  
J8712A supplies 600 W chassis power and 273 W PoE power.  
One J8712A can power the J8697A chassis.  
Two J8712A supplies are required to power the J8698A chassis.  
See the Ordering Guide for more details on power supply selection for  
PoE power.  
J8713A supplies 600 W chassis power and 900 W PoE power.  
See the Ordering Guide for more details on power supply selection for PoE  
power. Units shipped to North America include a NEMA L6-20P twist lock  
power cord. Non-locking NEMA 6-20P optionally available—see the  
Ordering Guide for more details.  
When used in the J8714A power shelf, the following specs apply (at  
full load):  
When used in the J8714A power shelf, the following specs apply (at  
full load):  
• Heat dissipation: 263 kJ/hr (250 BTU/hr) @ 110 V, 222 kJ/hr  
(210 BTU/hr) @ 220 V  
• Heat dissipation: 475 kJ/hr (450 BTU/hr) @ 220 V  
• Maximum current: 5.1 A @ 220 V  
• Maximum current: 3.2 A @ 110 V, 1.7 A @ 220 V  
NEW ProCurve 620 Redundant/External Power Supply  
(J8696A)  
Provides redundant system power and/or extra PoE power for up to two  
switches simultaneously  
NEW ProCurve Switch zl Power Supply Shelf (J8714A)  
A rack-mountable chassis with two slots for Switch zl power supplies to  
supply additional PoE power to a zl switch beyond what can be provided by  
the switch internal power supplies alone  
Ports  
2 EPS ports  
Ports  
2 RPS ports; 195 W available per port  
2 EPS ports; 398 W available per port  
PoE power available depends on power supplies installed  
Physical characteristics  
Dimensions (D x W x H): 24.71 x 44.3 x 13.2 cm  
(9.73 x 17.44 x 5.2 in.) (3U height)  
Physical characteristics  
Dimensions (D x W x H): 39.12 x 44.2 x 4.39 cm  
(15.4 x 17.4 x 1.73 in.) 1U height  
Weight: 6.89 kg (15.2 lb.)  
Weight: 4.2 kg (9.26 lb.) (no power supplies installed)  
Environment  
Electrical characteristics  
Operating temperature: 0°C to 55°C (32°F to 131°F)  
Operating relative humidity: 15% to 95% at 40°C (104°F), non-condensing  
Non-operating/Storage temperature: –40°C to 70°C (–40°F to 158°F)  
Non-operating/Storage relative humidity: 15% to 95% at 40°C (104°F),  
non-condensing  
Maximum heat dissipation: 422 kJ/hr (400 BTU/hr) for the actual 620  
itself. PoE-powered device heat dissipation assumed to be outside the  
620.  
Voltage: 100–127 VAC/200–240 VAC  
Current: 16 A/8 A  
Power consumption: 1440 W  
RPS power: 390 W  
Altitude: up to 3 km (10,000 ft.)  
Acoustic: power: 52.9 dB, pressure: 42.9 dB  
PoE power: 796 W  
RPS: 12 V  
PoE: –50 V  
Frequency: 50/60 Hz  
Note: Above figures are for max. RPS and PoE power being supplied to 2  
switches simultaneously. 200–240 V power cords shipped with the 620  
have a wall plug rated as close to 13 A as specific country standards  
allow.  
Electrical characteristics  
Description: Power draw and heat dissipation for the power shelf are  
dependent on the power supplies installed.  
Note: For heat dissipation and power requirements of the power shelf, find  
and add together these figures for the 1 or 2 power supplies actually  
installed.  
Notes  
The ProCurve Switch zl Power Supply Shelf has two slots for zl power  
supplies. It supplies PoE power only to zl switches. For yl switches, see  
the ProCurve 620 Redundant/External Power Supply.  
Power shelf depth includes 1.9 cm (0.75 in.) due to the power supply  
handles.  
Notes  
The ProCurve 620 supports the ProCurve 2900 series (RPS), 3500yl  
series (RPS/PoE), and 6200yl (RPS) switches.  
The ProCurve 5400zl switches are not supported.  
The ProCurve 620 includes 4 2-meter RPS/EPS cables. These cables can  
be used to carry either RPS or PoE power to the switch being powered.  
Power supplies not included.  
Services for accessories are covered under the product in which they are installed.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ProCurve Switch 5400zl/3500yl Series Modules  
For more information  
Additional accessories  
ProCurve Wireless Edge Services zl Module  
(J9051A)  
To learn more about ProCurve  
Networking, please visit  
ProCurve Redundant Wireless Services zl  
Module (J9052A)  
ProCurve Gigabit-SX-LC Mini-GBIC (J4858C)  
ProCurve Gigabit-LX-LC Mini-GBIC (J4859C)  
ProCurve Gigabit-LH-LC Mini-GBIC (J4860C)  
ProCurve Gigabit 1000Base-T Mini-GBIC  
(J8177B)*  
ProCurve 100-FX SFP-LC Transceiver (J9054B)  
ProCurve 10-GbE X2-SC SR Optic (J8436A)  
ProCurve 10-GbE X2-SC LR Optic (J8437A)  
ProCurve 10-GbE X2-SC ER Optic (J8438A)  
ProCurve 10-GbE CX4 Media Converter (J8439A)  
ProCurve 10-GbE X2-CX4 Transceiver (J8440B)  
ProCurve Identity Driven Manager 2.2 base  
product—500-user license (J9012A)  
ProCurve Manager Plus 2.2 unlimited-device  
license (J9059A)  
* Not supported on dual-personality ports on 3500yl series.  
© 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change  
without notice. The only warranties for HP products and services are set forth in the express warranty statements  
accompanying such products and services. Nothing herein should be construed as constituting an additional  
warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.  
ARM is a registered trademark of ARM Limited.  
4AA1-6637EEE, January 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Boiler 9047 User Manual
Hafler Stereo Amplifier DH 500 User Manual
Hafler Stereo Amplifier PRO 1200 User Manual
Hamilton Beach Coffeemaker 48463 User Manual
Hamilton Beach Hot Beverage Maker 40886 User Manual
Hamilton Beach Rice Cooker 840106800 User Manual
Heatcraft Refrigeration Products Fan BN LOPTB User Manual
HP Hewlett Packard Server 721546 001 User Manual
Hunter Fan Outdoor Ceiling Fan 21100 User Manual
IBM Printer 1725 SLS User Manual