Harbor Freight Tools Portable Generator 92863 User Manual

GENERATOR  
6 HP ROBIN ENGINE RECOIL START  
2800 WATT (PEAK)  
Model 92863  
OPERATING INSTRUCTIONS  
Due to continuing improvements, actual product may differ slightly from the product described herein.  
®
3491 Mission Oaks Blvd., Camarillo, CA 93011  
TO PREVENT SERIOUS INJURY,  
READ AND UNDERSTAND ALL WARNINGS  
AND INSTRUCTIONS BEFORE USE.  
Copyright© 2005 by Harbor Freight Tools®. All rights reserved. No portion of this  
manual or any artwork contained herein may be reproduced in any shape or form  
without the express written consent of Harbor Freight Tools.  
For technical questions, please call 1-800-444-3353.  
REV 08/05  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WORK AREA  
1.  
2.  
Keep your work area clean and well lit. Cluttered benches and dark areas  
invite accidents.  
Do not operate the Generator and power tools in explosive atmospheres,  
such as in the presence of flammable liquids, gases, or dust. Generators  
and power tools create sparks which may ignite the dust or fumes.  
3.  
1.  
Keep bystanders, children, and visitors away while operating the Generator  
and power tools. Provide barriers or shields as needed.  
ELECTRICAL SAFETY  
Grounded tools must be plugged into an outlet properly installed and  
grounded in accordance with all codes and ordinances. Never remove the  
grounding prong or modify the plug in any way. Do not use any adapter  
plugs. Check with a qualified electrician if you are in doubt as to whether  
the outlet is properly grounded. If the tools should electrically malfunction or  
break down, grounding provides a low resistance path to carry electricity away  
from the user.  
2.  
3.  
Double insulated tools are equipped with a polarized plug (one blade is  
wider than the other). This plug will fit in a polarized outlet only one way. If  
the plug does not fit fully in the outlet, reverse the plug. If it still does not fit,  
contact a qualified electrician to install a polarized outlet. Do not change the plug  
in any way. Double insulation  
eliminates the need for the three wire grounded  
power cord and grounded power supply system.  
Tools marked with “Grounding Required” have a three wire cord and a  
three prong grounding plug. The plug must be connected to a properly  
grounded outlet. If the tool should electrically malfunction or break down,  
grounding provides a low resistance path to carry electricity away from the user,  
reducing the risk of electric shock. Do not modify the power cord plug provided  
with the tool. Never remove the grounding prong from the plug.  
4.  
5.  
Avoid body contact with grounded surfaces such as pipes, radiators,  
ranges, and refrigerators. There is an increased risk of electric shock if your  
body is grounded.  
Do not expose the Generator or power tools to rain or wet conditions.  
Water entering the Generator or power tools will increase the risk of electric  
shock.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.  
Do not abuse Power Cords on tools. Never use a Power Cord to carry the  
tools or pull the Plug from the Generator’s outlet. Keep Power Cords away  
from heat, oil, sharp edges, or moving parts. Replace damaged Power  
Cords immediately. Damaged Power Cords increase the risk of electric shock.  
PERSONAL SAFETY  
1.  
2.  
Stay alert. Watch what you are doing, and use common sense when  
operating the Generator. Do not use the Generator while tired or under the  
influence of drugs, alcohol, or medication. A moment of inattention while  
operating the Generator may result in serious personal injury.  
Dress properly. Do not wear loose clothing or jewelry. Contain long hair.  
Keep your hair, clothing, and gloves away from moving parts. Loose  
clothes, jewelry, or long hair can be caught in moving parts.  
3.  
4.  
Avoid accidental starting. Make sure the Power Switch is in its “OFF”  
position, and disconnect the Spark Plug Wire when not in use.  
Remove adjusting keys or wrenches before turning the Generator on. A  
wrench or a key that is left attached to a rotating part of the Generator may result  
in personal injury.  
5.  
6.  
Do not overreach. Keep proper footing and balance at all times.  
Use safety equipment. Always wear eye protection. Wear ANSI approved  
safety impact eye goggles when operating the Generator. Dust mask, non-skid  
safety shoes, hard hat, or hearing protection must be used for appropriate  
conditions.  
7.  
8.  
Do not force the Generator. Use the Correct Generator for your application.  
The correct Generator will do the job better and safer at the rate for which it is  
designed.  
Do not use the Generator if the Power Switch does not turn it on or off. Any  
Generator that cannot be controlled with the Power Switch is dangerous and  
must be replaced.  
GENERATOR USE AND CARE  
1.  
Make sure the Power Switch is in its “OFF” position and disconnect the  
spark plug wire before making any adjustments, changing accessories, or  
storing the Generator. Such preventive safety measures reduce the risk of  
starting the Generator accidentally.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.  
3.  
Store idle generators out of reach of children and other untrained persons.  
Generators are dangerous in the hands of untrained users.  
Maintain the Generator with care. Do not use a damaged Generator. Tag  
damaged Generators “Do not use” until repaired.  
4.  
5.  
Check for misalignment or binding of moving parts, breakage of parts, and  
any other condition that may affect the generator’s operation. If damaged,  
have the Generator serviced before using. Many accidents are caused by  
poorly maintained Generators.  
Use only accessories that are recommended by the manufacturer for your  
model. Accessories that may be suitable for one Generator may become  
hazardous when used on another Generator.  
SERVICE  
1.  
2.  
Generator service must be performed only by qualified repair personnel.  
Service or maintenance performed by unqualified personnel could result in a risk  
of injury.  
When servicing a Generator, use only identical replacement parts. Follow  
instructions in the “Inspection, Maintenance, And Cleaning” section of this  
manual. Use of unauthorized parts or failure to follow maintenance instructions  
may create a risk of electric shock or injury.  
SPECIFIC PRODUCT WARNINGS AND PRECAUTIONS  
1.  
2.  
WARNING! The warnings, precautions, and instructions discussed in this  
manual cannot cover all possible conditions and situations that may occur. The  
operator must understand that common sense and caution are factors, which  
cannot be built into this product, but must be supplied by the operator.  
WARNING! People with pacemakers should consult their physician(s)  
before using this product. Electromagnetic fields in close proximity to a heart  
pacemaker could cause interference or failure of the pacemaker. In addition,  
people with pacemakers should adhere to the following: Caution is necessary  
when near the coil, spark plugs, or distributor of a running engine. The engine  
should always be off if adjustments are to be made to the distributor.  
3.  
Industrial applications must follow OSHA requirements.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.  
Maintain labels and nameplates on the Generator. These carry important  
information. If unreadable or missing, contact Harbor Freight Tools for a  
replacement.  
Installation Precautions:  
1.  
WARNING! Before using the Generator, read and understand the Engine  
manufacturer’s Operation, Maintenance, and Parts manual. Also, read the safety  
precautions in this manual. These should always be followed to reduce the risk of  
personal injury and damage to equipment.  
2.  
Ensure installation meets all applicable safety, and local and national electrical  
codes. Have installation performed by a qualified, licensed electrician and  
building contractor.  
3.  
4.  
5.  
All electrical work, including the earth-ground connection, should be completed  
by a licensed electrician.  
Any separate fuel storage Generator supply facility must be built or installed in  
full compliance with all relevant local, state, and federal regulations.  
If the Generator is installed indoors, exhaust fumes must be piped out of the  
building using leak-free, heat-resistant piping. Use the Generator only in well  
ventilated outdoor areas. Carbon monoxide fumes are a colorless, odorless  
gas that, if inhaled, can cause serious injury or death. Pipes and silencer  
should not use any flammable materials, nor should they be installed near the  
same. Generator exhaust fumes must be within legal limits.  
6.  
If the Generator is installed outdoors, it must be weatherproofed and should be  
soundproofed. It should not be run outdoors without protection to the Generator  
and wiring conduit.  
7.  
8.  
Never lift the Generator using the engine or alternator lifting lugs. Connect lifting  
equipment to the Frame of the Generator.  
Before lifting the Generator, ensure the lift rigging and supporting structure are in  
good condition, and are rated to lift such a load.  
9.  
Keep all personnel away from the suspended Generator during relocating.  
10.  
The supporting floor/ground surface should be level, and strong enough to safely  
hold the weight of the Generator. If the floor/ground surface is not level, strong  
cross members should be placed under the full length of the Generator Frame at  
its low side.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11.  
12.  
For trailer installation, the Generator should be mounted on the center point of  
the trailer, over the wheels. Consult your local DMV for possible installation  
regulations.  
Install sound and weather proofing only when it is not raining or snowing to avoid  
trapping moisture within the Generator’s area.  
Fire And Explosion Precautions:  
1.  
Gasoline fuel and fumes are flammable, and potentially explosive. Use proper  
fuel storage and handling procedures. Always have multiple ABC class fire  
extinguishers nearby.  
2.  
3.  
Keep the Generator and surrounding area clean at all times.  
When spills of fuel or oil occur, they must be cleaned up immediately. Dispose of  
fluids and cleaning materials as per any local, state, or federal codes and  
regulations. Store oil rags in a covered metal container.  
4.  
5.  
Never store fuel or other flammable materials near the Generator.  
Do not smoke, or allow sparks, flames or other sources of ignition around the  
Engine and Fuel Tank. Fuel vapors are explosive.  
6.  
Keep grounded conductive objects, such as tools, away from exposed, live  
electrical parts and connections to avoid sparking or arcing. These events could  
ignite fumes or vapors.  
7.  
8.  
Do not refill the FuelTank while the Engine is running or while the Engine is  
still hot. Do not operate the Generator with known leaks in the fuel system.  
Excessive buildup of unburned fuel gases in the exhaust system can create a  
potentially explosive condition. This buildup can occur after repeated failed start  
attempts, valve testing, or hot engine shutdown. If this occurs, open exhaust  
system drain plugs, if equipped, and allow the gases to dissipate before  
attempting to restart the Generator.  
9.  
Use only engine manufacturer recommended fuel and oil.  
Mechanical Precautions:  
1. ALWAYS make sure the Power Switch is in its “OFF” position. Disconnect the  
spark plug wire, and allow the Engine to completely cool before carrying out  
maintenance.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.  
Check for damaged parts. Before using the Generator, any part that appears  
damaged should be carefully checked to determine that it will operate properly  
and perform its intended function. Check for alignment and binding of moving  
parts, any broken parts or mounting fixtures, and any other condition that may  
affect proper operation. Any part that is damaged should be properly repaired or  
replaced by a qualified technician.  
3.  
4.  
The Generator is designed with guards for protection from moving parts. In any  
case, care must still be taken to protect personnel and equipment from other  
mechanical hazards when working around the generator.  
Do not operate the Generator with safety guards removed. While the Generator  
is running, do not attempt to reach around the safety guards for maintenance or  
any other reason.  
5.  
6.  
7.  
8.  
9.  
Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts.  
Be aware that when engine parts are moving fast they cannot be seen clearly.  
Keep access doors on enclosures closed and locked when access is not  
required.  
When working on or around the Generator always wear protective clothing  
including ANSI approved safety gloves, safety eye goggles, and safety hat.  
Do not alter or adjust any part of the Generator that is assembled and supplied  
by the manufacturer.  
Always follow and complete scheduled Engine and Generator maintenance.  
Chemical Precautions:  
1.  
2.  
Avoid contact with hot fuel, oil, exhaust fumes, and solid surfaces.  
Avoid body contact with fuels, oils, and lubricants used in the Generator. If  
swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is  
swallowed. For skin contact, immediately wash with soap and water. For eye  
contact, immediately flush eyes with clean water.  
Noise Precautions:  
1. Prolonged exposure to noise levels above 85 dBA is hazardous to hearing.  
Always wear ANSI approved ear protection when operating or working around  
the Generator when it is running.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Precautions:  
1.  
All connections and conduits from the Generator to the load must only be installed  
by trained and licensed electricians, and in compliance with all relevant local,  
state, and federal electrical codes and standards, and other regulations where  
applicable.  
2.  
The Generator must be earth-grounded in accordance with all relevant electrical  
codes and standards before operation.  
®
3.  
4.  
If an extension cord (not included) is used, make sure to use only UL listed cords  
having the correct gauge and length. (See Figure A.)  
Do not attempt to connect or disconnect load connections while standing in water,  
or on wet or soggy ground.  
5.  
6.  
Do not touch electrically energized parts of the Generator and interconnecting  
cables or conductors with any part of the body, or with any non-insulated  
conductive object.  
Connect the generator only to a load or electrical system (120 volt) that is  
compatible with the electrical characteristics and rated capacities of the  
Generator.  
7.  
8.  
Before servicing equipment powered by the Generator, disconnect the equipment  
from its power input.  
Keep all electrical equipment clean and dry. Replace any wiring where the  
insulation is cracked, cut, abraded or otherwise degraded. Replace terminals that  
are worn, discolored, or corroded. Keep terminals clean and tight.  
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*  
(110 VOLT)  
NAMEPLATE  
AMPERES  
EXTENSION CORD LENGTH  
(At Full Load)  
25  
FEET  
18  
18  
18  
18  
16  
14  
12  
50  
FEET  
18  
18  
18  
16  
14  
12  
10  
75  
FEET  
18  
18  
16  
14  
12  
10  
-
100  
FEET  
18  
16  
14  
12  
10  
-
150  
FEET  
0-2.0  
2.1-3.4  
3.5-5.0  
16  
14  
12  
12  
-
5.1-7.0  
7.1-12.0  
12.1-16.0  
16.1-20.0  
-
-
-
*Based on limiting the line voltage drop  
to five volts at 150% of the rated amperes.  
FIGURE A  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9.  
Insulate all connections and disconnected wires.  
10.  
Guard against electric shock. Prevent body contact with grounded surfaces such  
as pipes, radiators, ranges, and refrigerator enclosures.  
11.  
Use only Class BC or Class ABC fire extinguishers on electrical fires.  
INSTALLATION  
1.  
NOTE: Prior to powering tools and equipment, make sure the Generator’s rated  
voltage, wattage, and amperage capacity (120V/20 AMPs) is adequate to supply  
all electrical loads that the unit will power. If powering exceeds the Generator’s  
capacity, it may be necessary to group one or more of the tools and/or equipment  
for connection to a separate Generator.  
2.  
3.  
Electrical and other permits may be required for the installation of emergency  
power systems. Investigate the local building and electrical codes before  
installing this unit. Installation must be completed by licensed contractors.  
WARNING! The Generator weighs 95.7 Lbs. (without fuel). Use care and  
the proper lifting or hoisting equipment when moving it to the installation location.  
Always connect hoist lines to the Frame (18) of the Generator.  
GENERAL LOCATION  
1.  
2.  
It is recommended to locate and install the Generator outdoors where cooling air  
is readily available.  
Install the Generator so that the air inlets and outlets are not blocked by  
obstructions such as bushes, trees, or snow drifts. Locating it in the path of heavy  
winds or snowdrifts may require the placement of a barrier for protection. The air  
inlet, in normal weather conditions, should face the prevailing wind direction.  
3.  
4.  
Install the Generator on a concrete slab or other area where rain drainage or  
flood waters can not reach it.  
Generator placement should allow four feet of access to all sides for  
maintenance.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.  
6.  
Place the Generator as close as possible to the electrical tools and equipment  
being powered to reduce the length of extension cords.  
If the Generator in located indoors, or in a Generator house, the Engine exhaust  
must be ventilated to the outdoors using leakproof, heat resistant, flexible, metal,  
flex tubing.  
GENERATOR SUPPORT AND MOUNTING  
1.  
Mount the Generator on a concrete slab capable of supporting the weight of the  
Generator. The slab must extend on all sides beyond the Frame (18) by at least  
one foot. Contact a cement contractor for slab specifications if necessary. Attach  
the Frame to the concrete slab using 3/8” diameter expansion anchor bolts (not  
supplied).  
GROUNDING THE GENERATOR  
1.  
2.  
NOTE: It is recommended that only a trained and licensed electrician perform  
this procedure.  
Connect a #6 AWG grounding wire (not included) from the Ground Connector  
(17) on the Generator to a grounding rod (not included) that has been driven at  
least 24 inches deep into the earth. The grounding rod must be an earth-driven  
copper or brass rod (electrode) which can adequately ground the Generator.  
(See Figure B.)  
GROUND CONNECTOR  
(17)  
#6 AWG WIRE  
(NOT INCLUDED)  
GROUNDING ROD  
(NOT INCLUDED)  
FIGURE B  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
NOTE:  
For additional references to the parts discussed in the following pages,  
refer to the Assembly Diagram on page 18 of this manual.  
Pre-Start Checks:  
1.  
Before operation, it will be necessary to refer to the Engine manufacturer’s  
Operation, Maintenance, and Parts manual (included) for detailed information  
about starting, running, and stopping the Engine.  
2.  
IMPORTANT! Engine oil MUST be added to the Engine’s crankcase prior to  
starting and running the Engine. Failure to add oil, according to the Engine  
manufacturer’s recommendations, will damage the Engine and void its warranty.  
3.  
4.  
Check to make sure the Engine’s “ON/OFF” Switch is in its “OFF” position.  
(See Figure C.)  
Unscrew and remove one of the Engine’s Oil Dipsticks located on both sides at  
the bottom of the Engine Crankcase. Fill the Engine’s crankcase with the proper  
type and amount of engine oil as recommended by the Engine manufacturer.  
Then, replace the Oil Dipstick. (See Figure C.)  
“ON/OFF”  
SWITCH  
OIL  
DIPSTICK  
FIGURE C  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5.  
Before the first use, remove the Fuel Tank Cap (30) and fill the Fuel Tank (26)  
with unleaded gasoline. Then, replace the Fuel Tank Cap. Thereafter, check the  
Engine’s Fuel Gauge (27) for the amount of unleaded gasoline in the Fuel Tank.  
If necessary, refill the Fuel Tank with unleaded gasoline. (See Figure D.)  
FUEL TANK  
CAP  
(30)  
FUEL TANK  
(26)  
FUEL GAUGE  
(27)  
FIGURE D  
FUEL TANK (32)  
To Start The Generator:  
1.  
IMPORTANT! Engine oil MUST be added to the Engine’s crankcase prior to  
starting and running the Engine. Failure to add oil, according to the Engine  
manufacturer’s recommendations, will damage the Engine and void its warranty.  
2.  
Turn the Fuel Valve (25) to its “OPEN” position.  
(See Figure E, next page.)  
3.  
4.  
Move the Engine’s Fuel Choke to its “START” position. (See Figure E.)  
Turn the Engine’s “ON/OFF” Switch to its “ON” position  
(See Figure E.)  
5.  
6.  
Grasp the Handle of the Engine’s Starter Rope and rapidly pull the Starter Rope  
to start the Engine. NOTE: It may take one or more pulls on the Starter Rope to  
start the Engine.  
Allow the Engine to run for several seconds, then move the Engine’s Fuel Choke  
all the way to the left to its “RUN” position. (See Figure E.)  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FUEL VALVE (25)  
“ON/OFF” SWITCH  
FUEL CHOKE  
STARTER ROPE  
FIGURE E  
Powering Tools And Equipment:  
1.  
Prior to powering tools and equipment, make sure the Generator’s rated voltage,  
wattage, and amperage capacity (120V/20 AMPs) is adequate to supply all  
electrical loads that the unit will power. If powering exceeds the Generator’s  
capacity, it may be necessary to group one or more of the tools and/or equipment  
for connection to a separate generator.  
2.  
Once the Generator is running, simply connect the Power Cords of 120 volt  
powered tools and equipment into the 120 volt Dual Outlets (35).  
(See Figure F, next page.)  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
120 VOLT OUTLET (35)  
120 VOLT OUTLET (35)  
CIRCUIT BREAKER  
(34)  
FIGURE F  
3.  
NOTE: The Generator features an AC Non-Fuse Circuit Breaker (34) to protect  
the AC circuit in case of an overload. Should an overload occur the Circuit  
Breaker will “trip”, causing the Generator to automatically shut down. In this  
case, refer to Step #1. Then, reset the circuitry system by depressing the Circuit  
Breaker. Restart the Generator and continue powering the remaining tools and  
equipment. (See Figure F.)  
4.  
5.  
When finished using the Generator, turn the ON/OFF Switch to its “OFF”  
position to stop the Generator. (See Figure E.)  
After the Engine and Generator have completely cooled, store the Generator in a  
safe, clean, dry location out of reach of children and other unauthorized people.  
INSPECTION, MAINTENANCE, AND CLEANING  
1.  
2.  
NOTE: Preventative maintenance procedures and frequency will vary depending  
on the amount of Generator use. Refer to the Engine manufacturer’s Operation,  
Maintenance, and Parts manual (included) for detailed information regarding  
maintenance of the Engine.  
CAUTION! Always make sure the ON/OFF Switch is in itsOFF” position.  
Disconnect the spark plug wire from the engine. And allow sufficient time  
for the Engine and Generator to completely cool before performing any  
inspection, maintenance, or cleaning.  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.  
Before each use: Inspect the general condition of the Generator. Check for  
loose screws, misalignment or binding of moving parts, cracked or broken parts,  
damaged electrical wiring, and any other condition that may affect its safe  
operation. If abnormal noise or vibration occurs, have the problem corrected  
before further use. Do not use damaged equipment.  
4.  
5.  
Before each use: Check to make sure the Engine’s oil level is adequate. Refer  
to the Engine manufacturer’s Operation, Maintenance, and Parts Manual  
(included) for specific information.  
Prior to refilling the Fuel Tank: Remove the Fuel Tank Cap (30) to expose the  
Filter (32). Remove the Filter and inspect it for an accumulation of dirt and debris.  
If necessary, clean the Filter using unleaded gasoline or a mild solvent. Then,  
replace the Filter. Fill the Fuel Tank (26) with unleaded gasoline, and replace the  
Fuel Tank Cap. (See Figure G.)  
6.  
7.  
Daily: With a soft brush, cloth, or vacuum, remove all debris from the Generator.  
Then, use a premium quality, lightweight machine oil to lubricate all moving parts.  
FUEL TANK 26)  
WARNING!  
FILTER (32)  
All maintenance, service,  
and repairs not listed in  
this manual are only to be  
attempted by a qualified  
technician.  
FIGURE G  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PLEASE READ THE FOLLOWING CAREFULLY  
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY  
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR  
DISTRIBUTOR MAKES ANY REPRESENTATION ORWARRANTY OF ANY KINDTO THE BUYERTHAT HE  
OR SHE IS QUALIFIEDTO MAKE ANY REPAIRSTO THE PRODUCT, ORTHAT HE OR SHE IS QUALIFIED  
TO REPLACE ANY PARTS OFTHE PRODUCT. IN FACT, THE MANUFACTURER AND/OR DISTRIBUTOR  
EXPRESSLY STATESTHAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY  
CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER ASSUMES ALL  
RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR  
REPLACEMENT PARTSTHERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT  
PARTSTHERETO.  
PARTS LIST  
Part  
1
Description  
Connection Board  
Qty.  
1
Part  
Description  
Qty.  
4
21 Bolt (M5)  
2
Bolt (M6 x 130)  
Bolt (M5 x 12)  
Cable Sheath  
Rear Cover  
Bolt  
4
22 Heat Insulation Board  
23 Bolt (M6)  
1
3
2
4
4
1
24 Bolt (M5 x 35)  
25 Fuel Valve  
4
5
1
1
6
2
26 Fuel Tank  
1
7
Capacitor  
1
27 Fuel Gauge  
28 Bolt (M5 x 12)  
29 Bolt (M6 x 25)  
30 Fuel Tank Cap  
31 Seal Ring  
1
8
Alternator Back Cover  
Stator  
1
2
9
1
4
10 Bridge Combination  
11 Voltage Dependent Resistor  
12 Rotor  
2
1
2
1
1
32 Filter  
1
13 Hex Bolt (5/16"-24)  
14 Alternator Front Cover  
15 Shock Absorber Support  
16 Bolt (M10)  
4
33 Bolt (M5)  
4
1
34 Circuit Breaker  
35 Outlet 20A/120V  
36 Bolt (5/16"-24 x 170)  
37 Bolt(M5x16)  
38 Bolt(M5)  
1
4
2
4
1
17 Ground Connector  
18 Frame  
4
2
1
4
19 Bolt (M10)  
4
39 Bolt(M5x25)  
2
20 Shock Absorber  
4
NOTE:  
Some parts are listed and shown for illustration purposes only,  
and are not available individually as replacement parts.  
REV 08/05  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ASSEMBLY DIAGRAM  
NOTE:  
Some parts are listed and shown for illustration  
purposes only, and are not available individually as replacement parts.  
REV 08/05  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ELECTRICAL SCHEMATIC  
REV 08/05  
SKU 92863  
For technical questions, please call 1-800-444-3353.  
PAGE 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Clothes Dryer 234401 User Manual
Graco Thermometer 1769606 User Manual
Haier Air Conditioner HWF05XCK User Manual
HP Hewlett Packard Computer Monitor 663728R999F7PH User Manual
HP Hewlett Packard Network Card hn200e User Manual
HTC Cell Phone HS S200 User Manual
Husqvarna Snow Blower 96193005301 User Manual
IBM Laptop 1400 2611 User Manual
IBM Network Card RBF20CW User Manual
IKEA Plumbing Product AA 319118 2 User Manual