INSTRUCTIONS
SDMM8 Manual Meter and
SDMP8 Preset Meter
333492B
EN
For metered dispense of petroleum-based lubricants, oils and 50:50 antifreeze/water mix
fluids only.
For professional use only.
Maximum Working Pressure: 1500 psi (10 MPa, 103 bar)
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
Download from Www.Somanuals.com. All Manuals Search And Download.
Models
The following packages include Bare Meter Model 24U957 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
Inlet
Extension Nozzle/Extension Kit Nozzle Parts†
24V044
24V047
24V050
4/16 Liter
4/16 Liter
4/16 Liter
BSPT
BSPT
BSPT
Flex
Rigid
Gear Lube
24V475
255852
255854
255459
255459
255470
The following packages include Bare Meter Model 24U958 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
Inlet
Extension Nozzle/Extension Kit Nozzle Parts†
24V045
24V048
24V051
4/16 Liter
4/16 Liter
4/16 Liter
BSPP
BSPP
BSPP
Flex
Rigid
Gear Lube
24V475
255852
255854
255459
255459
255470
SDMP8 Preset Meters
Bare preset meters do not include a nozzle or extension. Model packages that include a nozzle and extension are
provided on page 4.
Model Number
Model Description
Inlet
24U947*
24U948*
24U949*
24U950*
24U951*
24U952*
24U953*
24U954*
24U955*
60 Quart
60 Quart
60 Quart
60 Gallon
60 Gallon
60 Gallon
60 Liter
NPT
BSPT
BSPP
NPT
BSPT
BSPP
NPT
60 Liter
60 Liter
BSPT
BSPP
*This meter can be used for antifreeze applications with antifreeze nozzle 255855 or 24W306. See page 24 for infor-
mation about these nozzles.
333492B
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Models
SDMP8 Preset Meters with Nozzle and Extension Packages
The following packages include Bare Meter Model 24U947 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V052 60 Quart
Inlet
NPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U948 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V053 60 Quart
Inlet
BSPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U949 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V054 60 Quart
Inlet
BSPP
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U950 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V055 60 Gallon
Inlet
NPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U951 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V056 60 Gallon
Inlet
BSPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U952 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V057 60 Gallon
Inlet
BSPP
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U953 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V058 60 Liter
Inlet
NPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U954 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V059 60 Liter
Inlet
BSPT
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
The following packages include Bare Meter Model 24U955 and the nozzle and extension kits indicated in the table
below.
Model Number Model Description
24V060 60 Liter
Inlet
Extension Nozzle/Extension Kit Nozzle Parts†
Rigid 24W641 255459
BSPP
4
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
Warnings
The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-
tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When
these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific
hazard symbols and warnings not covered in this section may appear throughout the body of this manual where
applicable.
FIRE AND EXPLOSION HAZARD
When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be
aware that flammable fumes can ignite or explode. To help prevent fire and explosion:
•
•
•
•
•
•
•
Use equipment only in well ventilated area.
Eliminate all ignition sources, such as cigarettes and portable electric lamps.
Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.
Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.
Ground all equipment in the work area.
Use only grounded hoses.
Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment
until you identify and correct the problem.
•
Keep a working fire extinguisher in the work area.
SKIN INJECTION HAZARD
High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This
may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical
treatment.
•
•
•
•
Do not point dispensing device at anyone or at any part of the body.
Do not put your hand over the fluid outlet.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Follow the Pressure Relief Procedure when you stop dispensing and before cleaning, checking, or
servicing equipment.
+
•
•
Tighten all fluid connections before operating the equipment.
Check hoses and couplings daily. Replace worn or damaged parts immediately.
333492B
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Warnings
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•
•
Do not operate the unit when fatigued or under the influence of drugs or alcohol.
Do not exceed the maximum working pressure or temperature rating of the lowest rated system
component. See Technical Data in all equipment manuals.
•
Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all
equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information
about your material, request MSDS from distributor or retailer.
•
•
•
Do not leave the work area while equipment is energized or under pressure.
Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.
Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu-
facturer’s replacement parts only.
•
Do not alter or modify equipment. Alterations or modifications may void agency approvals and create
safety hazards.
•
•
•
•
•
•
Make sure all equipment is rated and approved for the environment in which you are using it.
Use equipment only for its intended purpose. Call your distributor for information.
Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
Do not kink or over bend hoses or use hoses to pull equipment.
Keep children and animals away from work area.
Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical
reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or prop-
erty damage.
•
Do not use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or
fluids containing such solvents.
•
Many other fluids may contain chemicals that can react with aluminum. Contact your material sup-
plier for compatibility.
PERSONAL PROTECTIVE EQUIPMENT
Wear appropriate protective equipment when in the work area to help prevent serious injury, including
eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is
not limited to:
•
•
Protective eyewear, and hearing protection.
Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer
6
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Typical Installation
Typical Installation
A
L
K
R
F
B
D
C
G
P
E
M
J
S
H
N
FIG. 1
Key:
A
B
C
D
E
F
Main air supply line
Pump air supply line
Air filter
Air regulator
Bleed-type master air valve (required)
Pump
G
H
Pump grounding wire (required)
Pressure relief valve (required)
NOTE: The relief pressure cannot exceed the meter’s maximum working pressure
J
K
L
M
N
P
R
S
Fluid shut off valve
Fluid line
Fluid shut off valve
Hose reel
SDMM8 or SDMP8 meter
Mounting channel
Hose reel fluid inlet kit
Fluid drain valve
333492B
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
Installation
NOTE: The letters used in the following instructions
Grounding
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
• The equipment must be grounded to reduce the
risk of static sparking. Static sparking can cause
fumes to ignite or explode. Grounding provides
an escape wire for the electric current.
• To prevent electric arcing do not allow the
conductive metal surfaces on the meter to make
contact with any positively charged metal
surface, including (but not limited to), the starter
solenoid terminal, alternator terminal or battery
terminal.
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
Ground all components in the system:
1. Turn off power supply to the pump or close
upstream master air valve (E).
Pump (F): Follow manufacturer’s recommendations.
2. Open all fluid shut off valves (J and L) in the system.
Air and fluid supply lines (A, B, K): Only use electri-
cally conductive hoses. Check electrical resistance of
hoses. If total resistance to ground exceeds 29 meg-
ohms, replace hose immediately.
3. Trigger the meter (N) into a waste container to
relieve pressure.
4. Open fluid drain valves and leave them open until
you are ready to pressurize the system.
Air compressor: Follow manufacturer’s recommenda-
tions.
Fluid supply container: Follow local code.
To maintain grounding continuity when flushing or
relieving pressure: hold a metal part of the meter firmly
to the side of a grounded metal pail, then trigger the
valve.
SDMM8 and SDMP8 Meter (N): When installing the
meter leave at least two threads bare when using thread
sealant. The bare threads ensure a ground is main-
tained.
8
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
4. Slowly open the fluid shut off valve (J).
Pre-Installation Procedure
5. If you have multiple dispense positions, first flush
the dispense position farthest from the pump and
work your way toward the pump. Slowly open the
fluid shut-off valve (L) at the dispense position.
Flush out a sufficient amount of oil to ensure that the
entire system is clean; then close the valve.
NOTE: The letters used in the following instructions
21.
Installing Meter (FIG. 3)
)
2. Close all fluid drain valves.
1. If this is a new installation and the first time a meter
is installed, skip step 1.
Installation Procedure
For existing installations, to replace the meter (N):
NOTICE
•
If this is a new installation or if the fluid lines are
contaminated, flush the lines before you install the
metered valve. Contaminated lines could cause the
valve to leak.
b. Use two wrenches working in opposite direc-
tions to loosen meter and hose fitting. Remove
meter (N) from hose.
•
Never dispense compressed air with meter. Doing
so will damage meter.
N
1
Flushing
NOTE: The meter should not be installed for this proce-
dure.
1. Close the fluid shut-off valve (L) at each dispense
position.
FIG. 3
2. Apply thread sealant to the male threads of the hose
fitting. Leave at least two threads bare when using
thread sealant. The bare threads ensure a ground is
maintained.
2. Make sure:
•
•
all fluid drain valves are closed,
fluid shut off valve (J) is closed,
3. Thread the meter swivel (1) onto the hose fitting.
Use two wrenches working in opposite directions to
tighten meter securely to hose fitting.
and
•
the bleed-type master air valve (E) is open.
NOTE: Make sure you allow sufficient time for the seal-
ant to cure to the manufacturer’s recommendations
before circulating fluid through the system.
3. Place the end of the hose into a container for waste
oil. Secure the hose in the container so it will not
come out during flushing.
10
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
4. Install extension (102) to meter:
d. Wrench tighten extension nut (102a).
5. Install nozzle (101):
completely off tube threads.
NOTE: Do not use PTFE tape or thread sealant on
threads of nozzle (101). This could cause the fitting to
leak.
102
a. Thread nozzle (101) onto extension (102) as
.
102
102a
FIG. 4
101
NOTE: Do not use PTFE tape or thread sealant on
threads of extension (102). This could cause the fitting
to leak.
101a
b. Thread extension (102) into meter housing as
FIG. 7
b. Use an open-end adjustable wrench on flats of
• Only tighten nozzle with wrench on flats of the
nozzle bushing.
102
• Do not disassemble the bushing from noz-
zle. Disassembly will affect performance of the
nozzle.
FIG. 5
c. Align extension (102) with meter housing and
handle. Hand tighten extension nut (102a).
FIG. 6
333492B
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
The totalizer keeps a running total of the amounts dis-
pensed.
Operation
NOTE: The letters used in the following instructions
21.
1. Turn meter pointer (41) counter-clockwise to select
the desired volume.
1. Open fluid shut off valves (J and L).
2. Start pump (F) to pressurize system.
2. Turn automatic twist lock nozzle (101) clockwise to
open nozzle. Insert nozzle into the fluid receptacle
and pull the trigger (12).
3. Adjust the air pressure to the pump motor so the
fluid pressure is no greater than 1500 psi (103.4
bar, 10.34 MPa)
NOTE: The trigger latches automatically. Do not set
trigger to enable meter to dispense when it is unat-
tended.
NOTE: To ensure dispensing accuracy, before begin-
ning dispense, pull trigger to purge all air from the fluid
lines and meter.
The meter shuts off automatically when the set amount
of fluid is dispensed.
4. Continue operation with instructions for Preset Auto-
matic or Manual Shutoff Valve Instructions.
Manual Shutoff Valve
NOTE: Clean strainer (3a) regularly. See Parts, page
21.
NOTICE
SPLASH HAZARD
To avoid costly meter damage, never turn the Manual
Meter pointer (41) backwards (clockwise).
Do not trigger meter when nozzle is closed. Fluid
will build up behind the nozzle. Fluid can leak from
the nozzle and can unexpectedly be expelled when
the nozzle is opened. If the meter is accidentally trig-
gered with the nozzle closed, point the nozzle into a
waste bucket and slowly open the nozzle to relieve
pressure and expel the built up fluid.
41
Preset Automatic Shutoff
NOTE: Clean strainer (3a) regularly. See Parts, page
19.
FIG. 9
NOTICE
The totalizer keeps a running total of the amounts dis-
pensed.
To avoid costly meter damage, never turn the Preset
1. Turn automatic twist lock nozzle (101) counter-
clockwise to open nozzle. Insert nozzle into the fluid
receptacle and pull the trigger (12).
41
2. Watch the meter pointer (41) on the meter dial (37)
move. Release the trigger (12) when the desired
amount of fluid has been dispensed.
3. Turn the meter pointer (41) counter-clockwise to
return it to “0” before dispensing again. See FIG. 9
FIG. 8
12
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Troubleshooting
Relieve pressure, page 8, before you check or repair the meter. Be sure all other valves, controls and pump are
operating properly.
Problem
Cause
Solution
2. Remove meter from hose.
3. Clean or replace strainer (3a).
Strainer (3a) is clogged.
4. Install meter to hose (See Installing
5. If the problem remains, contact your
Graco distributor for repair or
replacement.
Pump pressure is low.
Increase pump pressure.
Slow or no fluid flow.
Twist lock nozzle not fully open.
Aim nozzle into bucket. Fully open noz-
zle.
Do not trigger meter when nozzle is
closed! If you do accidentally trigger
the meter with the nozzle closed, point
nozzle into a waste bucket and slowly
open the nozzle to relieve pressure and
expel built up fluid.
Fluid shut-off valve (J or L) is not fully open
(page 9).
Fully open fluid shut-off valve (J or L).
Foreign material is wedged in the meter
housing.
Contact your Graco distributor for repair
or replacement.
Meter leaks from twist lock nozzle.
Twist lock nozzle has a damaged seal.
Replace nozzle. See Step a in Installa-
tion Procedure, page 11.
•
It is important to distinguish
between the two causes of this
problem. A new nozzle will NOT
correct a fluid leak caused by a
faulty valve.
Valve has damaged or obstructed seals.
Clean valve assembly or replace.
Poor swivel/hose connection.
Apply PTFE tape (leave a minimum 2
engaged threads uncovered for electri-
cal continuity) or sealant to threads of
hose and tighten the connection. See
Meter leaks from swivel.
Poor swivel/meter housing connection.
Swivel seals have deteriorated and leak.
Torque the fitting to 20-25 ft.-lbs.
Replace swivel.
333492B
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
Service
5. Remove seal (18) and piston assembly (19). If the
piston assembly sticks, lightly tap the housing
Cleaning / Repairing the Fluid
Section
NOTE: Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
18
19
2. Close fluid shut off valve (L).
3. Remove nozzle (101) and extension (102).
FIG. 12
6. Insert a screwdriver into the notch of the piston
assembly (19) and pry off the piston cover (19d).
101
102
19d
19
FIG. 10
FIG. 13
4. Turn meter cap (17) counter-clockwise to unscrew
and remove it from the meter housing.
7. Clean the parts (19a-g) and blow them dry.
8. Reassemble the piston assembly (19) and install in
meter.
9. Install cover (17) on meter housing. Torque to 11-14
ft. lbs (14.9-18.9 N•m).
10. Install nozzle and extension assembly (101 and
102).
17
FIG. 11
14
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
4. Use a hex wrench to remove the plug setscrew.
SDMM8 Manual Meter Counter
Section Repair
Remove the plug (50), remove the pin (51), spring
Disassembly
50
51
52
NOTE: Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
53
FIG. 16
2. Remove the cover (44), small retaining ring (43),
5. Remove the large retaining clip (38) and then the
44
42
43
38
37
41
FIG. 14
3. Remove the needle pointer (41), springs (39) and
FIG. 17
6. Use a 2 mm hex wrench to remove the gear set-
41
39/40
34
35
33
32
FIG. 15
FIG. 18
333492B
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
3. Install the face plate panel (37) and large retaining
38
37
31
FIG. 19
FIG. 22
4. Install the lower pointer (52), spring (53), pin (51)
wrench to tighten the plug setscrew.
Reassembly
1. Install counter assembly (31).
50
51
52
31
53
FIG. 23
5. Install the needle pointer (41), springs (39) and pins
FIG. 20
Use a 2 mm hex wrench to tighten the gear set-
screw (33).
41
39/40
34
35
33
32
FIG. 24
FIG. 21
16
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
6. Install small retaining ring (43), pointer pin (41) and
3. Remove the needle pointer (41), springs (39) and
41
44
42
43
39/40
41
FIG. 25
FIG. 27
4. Remove the large retaining clip (38) and then the
SDMP8 Preset Meter Counter
Section Repair
38
37
Disassembly
NOTE: Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
FIG. 28
2. Remove the cover (44), small retaining ring (43),
5. Use a 2 mm hex wrench to remove the gear set-
44
43
34
33
32
FIG. 26
FIG. 29
333492B
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
31
3. Install face plate panel (37) and large retaining clip
38
37
FIG. 30
Reassembly
FIG. 33
4. Install the needle pointer (41), springs (39) and pins
31
41
39/40
FIG. 34
FIG. 31
35).
2. Install the gears (32, 34). Use a 2 mm hex wrench to
44
43
34
33
32
FIG. 32
FIG. 35
18
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
SDMM8 Manual Meter Parts
SDMM8 Manual Meter Parts
Models 24U959, 24U960, 24U961, 24U956,
24U957, 24U958
Ref A
Ref B
28
33
44
43
41
See
Ref B
19g
19f
50
35
42
51
34
36
19d
19b
39
40
40
39
19c
38
52
39
40
37
32
16
19a
33
31
19
11
2
See Ref A
2
15
1 1
3a
3b
5
6
7
8
9
10
14
18
46
29
12
13
17
3
14
15
16
49
45
47
2
48
1
2
3
Torque to 7-10 ft lbs (9-13 N.m)
Torque to 15-25 in. lbs (1.7-2.8 N.m)
Torque to 11-14 ft. lbs (14.9-18.9 N.m)
333492B
19
Download from Www.Somanuals.com. All Manuals Search And Download.
SDMM8 Manual Meter Parts
SDMM8 Manual Meter Parts
Models 24U959, 24U960, 24U961, 24U956, 24U957, 24U958
Ref
Part No. Description
GEAR, 10 teeth
Qty
Ref
Part No. Description
Qty
19f
19g
28
1
1
1
1
1
1
2
1
1
1
1
1
SWIVEL
1
GEAR, 21 teeth
238399
model 24U959, 24U956
24V467 KIT, SHAFT
24H383 model 24U960, 24U957
24H382 model 24U961, 24U958
HOUSING, meter
29
106560
PACKING, o-ring
31
24U352 COUNTER
2
3
1
1
32
33†
34
16X595 GEAR, worm-spur
16X589 SCREW, setting M4 x 6
16X588 GEAR. twins, 14-32
16X586 GEAR, 42 teeth
16X491 COVER, protector
DIAL
256164
KIT, strainer, includes 3a
and 3b
3a
3b
5
STRAINER
10
10
1
WASHER, plain
SPRING, compression
35
113493
36
6
15U704 SEAT, valve
1
37
7
15U701 SPRING, secondary
15U700 PLUNGER, trigger lift
16X485 SEAT, valve
1
16X597 models 24U959, 24U960,
24U961
8
1
16X596 models 24U956, 24U957,
24U958
9
1
10
11
12
13
14
15
16
17
18
19
121412
277673
O-RING, pack
ROD, push
1
38
16X498 CLIP, ring
1
3
3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
39†
40†
41†
42†
43†
44†
45
46
47
48
49
50†
51†
52†
53†
16X583 SPRING, inner and outer
16X592 PIN, inner and outer
16X576 NEEDLE, upper
16X584 SPRING, outer, pointer
17B784 RING, retaining
16X575 COVER, needle
15R013 LATCH, lever
15M886 TRIGGER
1
191315
113574
191552
110637
CAM
1
SEAL, o-ring
2
WASHER, flat
SCREW, mach, panhead
2
2
16X493 CAP, housing
1
156633
PACKING, o-ring
1
15R014 SPRING, latch
15R015 LATCH, arm
KIT, piston, includes
19a-19g
1
15R016 LATCH, pin
24V470 QUARTS, models
24U959, 24U960,
24U961
114680
PIN, dowel
16X580 PLUG
24V471 LITERS, models 24U956,
24U957, 24U958
16X582 PIN, outer pointer
16X578 NEEDLE, lower, casting
16X601 SPRING (not shown)
19a
PISTON, chamber
PISTON, oscillating
DIVIDER
1
1
1
1
1
19b
19c
19d
19e
Parts are included in Kit 24V460
† Parts are included in Kit 24V474
Parts are included in Kit 24V473
GEAR, cover
ROLLER (not shown)
20
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
SDMP8 Preset Meter Parts
SDMP8 Preset Meter Parts
Models 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955
Ref A
30
Ref B
44
41
19g
19f
See
Ref B
43b
19a
19c
34
42
35
39
19b
40
51
38
39
19d
40
45
50
1
46
1
37
43a
3b
3a
5
32
33
6
19
See Ref A
49
7
47
8
31
48
16
2
15
9
11
10
18
2
3
17
14
52
28
12
13
14
15
16
2
1
2
3
Torque to 7-10 ft lbs (9-13 N.m)
Torque to 15-25 in. lbs (1.7-2.8 N.m)
Torque to 11-14 ft. lbs (14.9-18.9 N.m)
333492B
21
Download from Www.Somanuals.com. All Manuals Search And Download.
SDMP8 Preset Meter Parts
SDMP8 Preset Meter Parts
Models 24U947, 24U948, 24U949, 24U950, 24U951, 24U952, 24U953, 24U954, 24U955
Ref
19b
Part No. Description
PISTON, oscillating
Qty
Ref
Part No. Description
Qty
1
1
1
1
1
1
1
1
1
SWIVEL
19c
19d
19e
19f
19g
28
DIVIDER
PISTON, chamber
ROLLER (not shown)
GEAR, 10 teeth
238399 model 24U947, 24U950,
24U953
24H383 model 24U948, 24U951,
24U954
24H382 model 24U949, 24U952,
24U955
GEAR, 21 teeth
106560 PACKING, o-ring
KIT, shaft
1
1
2
3
HOUSING, meter
1
30
256164 KIT, strainer, includes 3a
and 3b
24V468 models 24U947, 24U948,
24U949, 24U953, 24U954,
24U955
3a
3b
5
STRAINER
1
1
1
WASHER, plain
24V469 models 24U950, 24U951,
24U952
113493 SPRING, compression
15U704 SEAT, valve
15U701 SPRING, secondary
15U700 PLUNGER, trigger lift
16X485 SEAT, valve
121412 O-RING, packing
277673 ROD, push
1
1
1
1
1
1
1
1
2
2
2
1
1
1
1
6
31
COUNTER
7
24U354 model 24U947, 24U948,
24U949
8
24U353 model 24U950, 24U951,
24U952
9
10
11
12
13
14
15
16
17
18
19
24U352 model 24U953, 24U954,
24U955
1
16Y317 TRIGGER
32
‡
GEAR, worm-spur
16X497 CAM
16X594 models 24U947, 24U948,
24U949, 24U950, 24U951,
24U952
113574 SEAL, o-ring
191552 WASHER, flat
110637 SCREW, mach, panhead
16X494 CAP, housing
156633 PACKING, o-ring
16X593 models 24U953, 24U954,
24U955
1
1
1
33‡
34
16X589 SCREW, setting
16X585 GEAR, 45 teeth
16X490 COVER
KIT, piston, includes
19a-19h
35
24V470 QUARTS, models 24U947,
24U948, 24U949
GALLONS, models
24U950, 24U951, 24U952
24V471 LITERS, models 24U953,
24U954, 24U955
19a
GEAR, cover
1
22
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
SDMP8 Preset Meter Parts
Ref
Part No. Description
Qty
Ref
40
Part No. Description
Qty
1
2
36
16X587 GEAR, twin 11-44 teeth
(not shown) Models
16X581 PIN, inner and outer
pointer
24U947, 24U948, 24U949,
24U953, 24U954, 24U955
1
1
41
42
43
16X577 NEEDLE
16X584 SPRING, outer pointer
RING, retaining
1
16Y999 GEAR, twin 24-44 teeth
(not shown) Models
24U950, 24U951, 24U952
1
1
1
1
1
1
1
1
1
1
1
43a
43b
44
45
46
47
48
16X611
16X588 GEAR. twins, 14-32, (not
shown) Models 24U950,
24U951, 24U952
1
1
1
17B784
16X575 COVER, needle
16X606 BRACKET, valve, trigger
16X607 PIN, screw
16X613 SPRING, lock, pawl
PIN, lock, pawl
17A029 GEAR, 11-42 teeth (not
shown) Models 24U950,
24U951, 24U952
37
DIAL
16X599 model 24U947, 24U948,
24U949
49
50
51
52
16X610 LOCK, pawl
16X579 NEEDLE, plate
16X590 PIN
16X600 model 24U950, 24U951,
24U952
16X598 model 24U953, 24U954,
24U955
16X492 TRIGGER, guard
1
2
38
39
16X498 CLIP, ring
‡ Included in Kit 24V466
Included in Kit 24V472
Included in Kit 24V465
Included in Kit 24V461
16X583 SPRING, inner and outer
pointer
333492B
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Nozzle (101) and Extension (102) Kits
Nozzle (101) and Extension (102) Kits
Kit No.
Description
Fluid Type
Automatic, non-drip quick close nozzle with
rigid extension
255852*
Oil
Automatic, non-drip quick close nozzle with
flexible extension
24V475*
24W641*
Oil
Oil
Automatic, non-drip quick close nozzle with
short rigid extension
Non-drip, quick close nozzle with rigid
extension
255854
Gear Lube
Non-drip, quick close nozzle with rigid
extension
255855*
Antifreeze
Antifreeze
Non-drip, quick close nozzle with flexible
extension
24W306*
*Used for dispensing 5gpm (22.7 lpm) or less.
24
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Nozzle (101) Parts
Nozzle (101) Parts
Part No.
Description
Qty
Fluid Type
255459*
Automatic, non-drip, quick-close nozzle
• BODY, nozzle
Oil
1
1
1
1
1
1
• O-RING, packing
• SPRING, compression
• O-RING, packing
• STEM, nozzle, valve
• SEAT, valve
255460*
Automatic, non-drip, quick-close nozzle
• BODY, nozzle
Antifreeze
1
1
1
1
1
1
• SPRING, compression
• O-RING, packing
• STEM, nozzle, valve
• O-RING, packing
• SEAT, valve
255470
Non-drip, quick-close nozzle
• Housing
Gear Lube
1
1
1
1
1
• Body, nozzle
• O-RING, packing
• O-RING, packing
• Plug, Hollow, hex
*Used for dispensing 5gpm (22.7 lpm) or less.
333492B
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Data
Technical Data
Manual and Preset Meter
US
0.26 to 8 gpm
Metric
Flow rate*
1 to 30 lpm
Maximum working pressure
1500 psi
10 MPa, 103.4 bar
Weight
Manual Meter
Preset Meter
3.42 lbs
3.50 lbs
1.55 kg
1.58 kg
Length
Width
Height Manual Meter
Height Preset Meter
Maximum Totalizer Digits
Inlet
11.4 inches
3.94 inches
4.85 inches
6.33 inches
28.9 cm
10 cm
12.3 cm
16.08 cm
99,999 units**
1/2-14 NPT
1/2-14 BSPP
1/2-14 BSPT
Outlet
3/4-16 straight thread o-ring boss
Operating temperature range
Wetted parts
Fluid compatibility
-50 °F to 160°F
-45°C to 70°C
brass, aluminum, stainless steel, TPE
antifreeze, gear oil, crankcase oil
30 psi @ 4 gpm
Meter pressure loss
Accuracy - Manual Meter: Oil
Accuracy - Manual Meter: Antifreeze
Accuracy - Preset Meter: Oil or Antifreeze
+/- 1 percent
+/- 3 percent
+/- 3 percent
*Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.
**Rolls over to 00,000 after maximum value is reached.
26
333492B
Download from Www.Somanuals.com. All Manuals Search And Download.
Graco Extended Meter Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in
material and workmanship on the date of sale to the original purchaser for use. Graco will, for a period of five (5) years from the date of sale, repair
or replace any non-wear parts of the equipment determined by Graco to be defective. Graco will also for a period of one (1) year from the date of
sale, repair, or replace any wear parts of the equipment determined by Graco to be defective. This warranty applies only when the equipment is
installed, operated and maintained in accordance with Graco's written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty
installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of
non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with
structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or
maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of
the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned
to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs
will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or
consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT
MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to
the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these
warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or
the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the
negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into,
given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la
rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite
de ou en rapport, directement ou indirectement, avec les procédures concernées.
Graco Information
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original instructions. This manual contains English. MM 333492
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
November 2014
Download from Www.Somanuals.com. All Manuals Search And Download.
|