First Alert Smoke Alarm SCO7 User Manual

INTRODUCTION  
FIRE SAFETY TIPS  
USER’S MANUAL  
Follow safety rules and prevent hazardous situations: 1) Use smoking  
materials properly. Never smoke in bed. 2) Keep matches or lighters away  
from children; 3) Store flammable materials in proper containers; 4) Keep  
electrical appliances in good condition and don’t overload electrical circuits;  
5) Keep stoves, barbecue grills, fireplaces and chimneys grease- and debris-  
free; 6) Never leave anything cooking on the stove unattended; 7) Keep  
portable heaters and open flames, like candles, away from flammable  
materials; 8) Don’t let rubbish accumulate.  
Keep alarms clean, and test them weekly. Replace alarms immediately if  
they are not working properly. Smoke Alarms that do not work cannot alert  
you to a fire. Keep at least one working fire extinguisher on every floor, and  
an additional one in the kitchen. Have fire escape ladders or other reliable  
means of escape from an upper floor in case stairs are blocked.  
COMBINATION CARBON MONOXIDE & SMOKE ALARM  
WITH VOICE & LOCATION AND  
REMOTE CONTROL TEST/SILENCE  
Features:  
Separate sensors to detect smoke  
and CO; the two alarm systems  
work independently  
Voice with programmable location  
Separate audible and visual  
signals to indicate alarm levels  
of smoke or CO  
Remote infrared Test/Silence and  
programming  
BASIC SAFETY INFORMATION  
Powered by two “AAbatteries  
Side access drawer for easy  
battery replacement  
Dangers, Warnings, and Cautions alert you to important  
operating instructions or to potentially hazardous situations.  
Pay special attention to these items.  
This Smoke/CO Alarm is approved for use in single-family  
residences. It is NOT designed for marine or RV use.  
IMPORTANT! PLEASE READ CAREFULLY AND SAVE.  
This user’s manual contains important information about your Combination  
Carbon Monoxide & Smoke Alarm’s operation. If you are installing this  
Alarm for use by others, you must leave this manual—or a copy of it—with  
the end user.  
This combination Smoke/Carbon Monoxide Alarm has two separate  
alarms. The CO Alarm is not designed to detect fire or any other  
gas. It will only indicate the presence of carbon monoxide gas at  
the sensor. Carbon monoxide gas may be present in other areas.  
The Smoke Alarm will only indicate the presence of smoke that  
reaches the sensor. The Smoke Alarm is not designed to sense gas,  
heat or flames.  
Printed in Mexico  
Model SCO7  
M08-0048-005  
Q
06/06  
This Smoke/CO Alarm cannot operate without working batteries.  
Removing the batteries for any reason, or failing to replace the  
batteries at the end of their service life, removes your protection.  
NEVER ignore any alarm. See “If Your Smoke/CO Alarm Sounds” for  
more information on how to respond to an alarm. Failure to  
respond can result in injury or death.  
The Silence Features are for your convenience only and will not  
correct a problem. See "Using the Silence Features" for details.  
Always check your home for a potential problem after any alarm.  
Failure to do so can result in injury or death.  
Test this Smoke/CO Alarm once a week. If the Alarm ever fails to  
test correctly, have it replaced immediately! If the Alarm is not  
working properly, it cannot alert you to a problem.  
This product is intended for use in ordinary indoor locations of  
family living units. It is not designed to measure CO levels in  
compliance with Occupational Safety and Health Administration  
(OSHA) commercial or industrial standards. Individuals with  
medical conditions that may make them more sensitive to carbon  
monoxide may consider using warning devices which provide  
audible and visual signals for carbon monoxide concentrations  
under 30 ppm. For additional information on carbon monoxide  
and your medical condition contact your physician.  
TABLE OF CONTENTS  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Fire Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1  
Step By Step Guide to Programming This Alarm . . . . . . . . . . . . . . . . . . . . .1  
What You Will See and Hear With This Alarm . . . . . . . . . . . . . . . . . . . . . .2  
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3  
Where to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2  
Where This Alarm Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . . . .2  
How to Install This Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
If Your Smoke/CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4  
What To Do First–Identify The Type Of Alarm . . . . . . . . . . . . . . . . . . . . . .3  
If the CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3  
If the Smoke Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4  
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
How Can I Protect My Family From CO Poisoning? . . . . . . . . . . . . . . . . . . .5  
Regulatory Information For Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . .5-6  
Regulatory Information for CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . .5  
Regulatory Information for Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . .5-6  
Recommended Locations for Smoke Alarms . . . . . . . . . . . . . . . . . . . .5-6  
About Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
Special Compliance Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6  
General Limitations Of Smoke/CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7  
STEP BY STEP GUIDE TO PROGRAMMING  
THIS ALARM  
For First Time and When Changing Batteries  
Action:  
Alarm Will Say:  
1. Insert batteries (2, AA batteries).  
Welcome, First Alert Carbon  
Monoxide and Smoke Alarm.”  
“No location programmed” if first  
time or “[Location, example:  
“Kitchen] location programmed”  
when changing batteries.  
To select location, press and hold  
test button now.”  
© 2006 BRK Brands, Inc. All Rights Reserved.  
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122  
Consumer Affairs: (800) 323-9005 • www.firstalert.com  
2. Press & Hold Test Button, or use  
your IR remote control’s channel or  
volume button, if you would like to  
program the location or change  
the location of the Alarm. Release  
button after Alarm responds.  
To save location, press and hold  
test button after location is heard.”  
Alarm will speak list of locations (see  
below).  
All First Alert® Smoke Alarms conform to regulatory requirements,  
including UL217 and are designed to detect particles of combustion.  
Smoke particles of varying number and size are produced in all fires.  
Ionization technology is generally more sensitive than photoelectric  
technology at detecting small particles, which tend to be produced  
in greater amounts by flaming fires, which consume combustible  
materials rapidly and spread quickly. Sources of these fires may include  
paper burning in a wastebasket, or a grease fire in the kitchen.  
3. After you hear the location of  
where you are placing the Alarm,  
Press & Hold the Test Button or  
use your IR remote control’s  
channel or volume button.  
[Location, example: “Kitchen]  
location saved.”  
If no location is chosen: “No location  
saved.”  
Photoelectric technology is generally more sensitive than ionization  
technology at detecting large particles, which tend to be produced in  
greater amounts by smoldering fires, which may smolder for hours  
before bursting into flame. Sources of these fires may include cigarettes  
burning in couches or bedding.  
For maximum protection, use both types of Smoke Alarms on each  
level and in every bedroom of your home.  
Your Alarm has now been programmed for the location of your choice.  
Available locations:  
Basement  
Hallway  
Kitchen  
Office  
Utility Room  
Child’s Bedroom  
Dining Room  
Family Room  
Guest Bedroom  
Living Room  
Master Bedroom  
No Location  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO INSTALL THIS ALARM  
IF YOUR SMOKE/CO ALARM SOUNDS  
WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM  
This combination Smoke/CO Alarm was designed to be mounted on the  
ceiling or wall. It is not a tabletop device. You must install this device on the  
ceiling or wall as outlined below. Read Where To Install This Alarm” before  
starting.  
Type of Alarm  
What You See and Hear  
Carbon Monoxide (CO)  
Voice: Warning, evacuate carbon  
monoxide in [Location,  
example: “Kitchen]. Evacuate.”  
____ ppm.”  
PARTS OF THIS SMOKE/CO ALARM  
Horn: 4 beeps, pause, 4 beeps, voice  
Power/Smoke LED: Off  
CO LED: Flashes Red  
1
Test/Silence Button and Remote  
Control Sensor  
2
3
4
Battery Compartment  
Power/Smoke Alarm LED  
CO Alarm LED  
Smoke  
Voice: Warning, evacuate smoke in  
[Location, example: “Kitchen].  
Evacuate.”  
Horn: 3 beeps, pause, 3 beeps, voice  
Power/Smoke LED: Flashes Red  
CO LED: Off  
Tools you will need: pencil, drill with 3/16” or 5mm drill bit,  
flathead screwdriver, hammer.  
Do not connect this unit to any other alarm or auxiliary device. It is a  
single-station unit that cannot be linked to other devices. Connecting  
anything else to this unit may prevent it from working properly.  
IF THE CO ALARM SOUNDS  
“ALARM-MOVE TO FRESH AIR”  
Do not install this unit over an electrical junction box. Air currents  
around junction boxes can prevent smoke from reaching the sens-  
ing chamber and prevent the unit from alarming. Only AC powered  
units are intended for installation over junction boxes.  
If you hear the CO alarm horn and the CO red light is flashing,  
move everyone to a source of fresh air.  
DO NOT remove the batteries!  
If you want to lock the battery compartment, or lock the Smoke/CO  
Alarm to the mounting bracket, please read the “Optional Locking  
Features” section in the “Programming Guide” attachment before you  
begin installation.  
Actuation of your CO Alarm indicates the presence of carbon monoxide  
(CO) which can kill you. In other words, when your CO Alarm sounds, you  
must not ignore it!  
IF THE CO ALARM SIGNAL SOUNDS:  
1. Operate the Test/Silence button.  
1. Hold base firmly and twist the mounting bracket counterclockwise (left) to  
separate it from the unit.  
2. Call your emergency services, fire department or 911. Write down the  
number of your local emergency service here:  
2. Hold the mounting bracket against the ceiling (or wall) so the vertical  
mounting slot is aligned in the 12 oclock position and trace around the  
inside of the mounting slots (vertical and horizontal mounting).  
__________________________________________________________________  
3. Put the unit where it won’t get covered with dust when you drill the mount-  
ing holes.  
3. Immediately move to fresh air—outdoors or by an open door or window.  
Do a head count to check that all persons are accounted for. Do not re-  
enter the premises, or move away from the open door or window until the  
emergency services responder has arrived, the premises have been aired  
out, and your CO Alarm remains in its normal condition.  
4. Using a 3/16” (5 mm) drill bit, drill a hole through the center of the oval  
outlines you traced.  
5. Insert the plastic screw anchors (in the plastic bag with screws) into the  
holes. Tap the screw anchors gently with a hammer, if necessary, until they  
are flush with the ceiling or wall.  
4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour  
period, repeat steps 1-3 and call a qualified appliance technician to investi-  
gate for sources of CO from fuel-burning equipment and appliances, and  
inspect for proper operation of this equipment. If problems are identified  
during this inspection have the equipment serviced immediately. Note any  
combustion equipment not inspected by the technician, and consult the  
manufacturers’ instructions, or contact the manufacturers directly, for more  
information about CO safety and this equipment. Make sure that motor  
vehicles are not, and have not, been operating in an attached garage or  
adjacent to the residence. Write down the number of a qualified appliance  
technician here:  
6. Line the mounting bracket up over the plastic screw anchors.  
7. Screw the mounting bracket to the ceiling or wall through the mounting  
slots using the two screws provided.  
8. Before attaching the Alarm to  
the bracket, insert the two (2)  
AA batteries (included) into the  
battery compartment. Match  
the terminals on the end of the  
battery with the terminals on  
the unit. Match “+” to “+” and  
“-” to “-.” If the batteries are  
not fully inserted, the unit  
__________________________________________________________________  
NOTE: A qualified appliance technician is defined as “a person, firm,  
corporation, or company that either in person or through a representative,  
is engaged in and responsible for the installation, testing, servicing, or replace-  
ment of heating, ventilation, air conditioning (HVAC) equipment, combustion  
appliances and equipment, and/or gas fireplaces or other decorative  
combustion equipment.”  
cannot receive battery power.  
NOTE: The unit may beep briefly when you install the batteries. This is normal.  
The GREEN Light flashes about every 60 seconds when the unit is  
receiving battery power.  
AFTER AN ALARM  
The battery door will resist closing unless batteries are installed. This  
warns you the unit will not operate without batteries.  
After the emergency responders arrive, the premises aired out, and your CO  
Alarm remains in its normal condition, you can check what the highest carbon  
monoxide level sensed was:  
9. Attach the Smoke/CO Alarm to the mounting  
bracket. Line up the guides on the alarm’s  
base with the guides on the mounting bracket.  
When guides are lined up, turn the base  
clockwise (right) until it snaps into place.  
Action:  
Alarm Will Say:  
1. Press & Hold Test Button  
“Highest carbon monoxide level was  
___ ppm. Please see manual.”  
To clear highest carbon monoxide  
level, press and hold test button  
now.”  
NOTE: Once the Smoke Alarm is snapped  
onto the mounting bracket, you can rotate  
the Smoke Alarm to adjust the alignment.  
2. Press & Hold Test Button, if you  
would like to clear the highest level  
sensed.  
“Highest carbon monoxide level  
cleared.”  
10. Test the Smoke/CO Alarm. See Weekly  
Testing” for details.  
If you would like to keep the  
highest level in memory, do not  
press anything.  
Alarm will say nothing.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
IF THE SMOKE ALARM SOUNDS  
RESPONDING TO AN ALARM  
WEEKLY TESTING  
NEVER use an open flame of any kind to test this unit. You might  
accidentally damage or set fire to the unit or to your home. The  
built-in test switch accurately tests the unit’s operation as required  
by Underwriters Laboratories, Inc. (UL). NEVER use vehicle exhaust!  
Exhaust may cause permanent damage and voids your warranty.  
If the unit alarms and you are not testing the unit, it is warning you  
of a potentially dangerous situation that requires your immediate  
attention. NEVER ignore any alarm. Ignoring the alarm may result in  
injury or death.  
Never remove the batteries from a battery operated Smoke/CO Alarm  
to stop an unwanted alarm (caused by cooking smoke, etc.).  
Removing batteries disables the alarm so it cannot sense smoke, and  
removes your protection. Instead open a window or fan the smoke  
away from the unit. The alarm will reset automatically.  
DO NOT stand close to the Alarm when the horn is sounding.  
Exposure at close range may be harmful to your hearing. When  
testing, step away when horn starts sounding.  
It is important to test this unit every week to make sure it is working  
properly. Using the test button is the recommended way to test this  
Smoke/CO Alarm.  
If the unit alarms get everyone out of the house immediately.  
1
WHAT TO DO IN CASE OF FIRE  
You can test this Smoke/CO Alarm two ways:  
• Don’t panic; stay calm. Follow your family escape plan.  
1. Manually: Press and hold the Test/Silence button on the  
Alarm cover until Alarm Voice says Testing” (typically  
3-5 seconds).  
• Get out of the house as quickly as possible. Don’t stop to get  
dressed or collect anything.  
• Feel doors with the back of your hand before opening them.  
If a door is cool, open it slowly. Don’t open a hot door. Keep doors  
and windows closed, unless you must escape through them.  
2. Using Your Remote Control: Standing no further than  
20 feet (6 meters) away from the Smoke/CO Alarm, aim  
your IR remote at the Alarm and press the CHANNEL or  
VOLUME button until Alarm Voice says Testing.  
• Cover your nose and mouth with a cloth (preferably damp).  
Take short, shallow breaths.  
2
• Meet at your planned meeting place outside your home,  
and do a head count to make sure everybody got out safely.  
• Call the Fire Department as soon as possible from outside.  
Give your address, then your name.  
• Never go back inside a burning building for any reason.  
• Contact your Fire Department for ideas on making your home safer.  
If the Alarm does not respond to your remote control, there may be an  
obstruction between you and the Alarm, you may be standing too far  
away, or your remote control may not be compatible.  
During testing, you will see and hear the following sequence:  
The Alarm Voice will say Testing.” The Horn will sound 3 beeps,  
pause, 3 beeps. The Alarm Voice will say Warning, evacuate smoke  
in [Location, example: “Kitchen]. Evacuate.” The Power/Smoke LED  
flashes Red and the CO LED will be Off.  
Alarms have various limitations. See "General Limitations of Smoke/CO  
Alarms" for details.  
Next the Horn will sound 4 beeps, pause, 4 beeps. The Alarm Voice  
will say Warning, evacuate carbon monoxide in [Location, example:  
“Kitchen]. Evacuate.” The Power/Smoke LED will be Off and the CO  
LED flashes Red.  
USING THE SILENCE FEATURES  
If the unit does not alarm, make sure the batteries are correctly installed, and  
test again. If the unit still does not alarm, replace it immediately.  
Never remove the batteries to quiet an unwanted alarm. Removing the  
batteries disables the alarm and removes your protection.  
The Silence Feature is intended to temporarily silence the horn while you  
identify and correct the problem. Do not use the Silence Feature in emergency  
situations. It will not correct a CO problem or extinguish a fire.  
REGULAR MAINTENANCE  
This unit has been designed to be as maintenance-free as possible, but there  
are a few simple things you must do to keep it working properly.  
The Silence Feature can temporarily quiet an unwanted alarm for several  
minutes. You can silence this Smoke/CO Alarm two ways:  
1. Manually: Press the Test/Silence button on the alarm cover for at least  
Use only the replacement batteries listed below. The unit may not  
operate properly with other batteries. Never use rechargeable batteries  
since they may not provide a constant charge.  
3-5 seconds.  
2. Using Your Remote Control: Standing no further than 20 feet (6 meters)  
away from the Alarm, aim your IR remote at the Alarm and press the  
CHANNEL or VOLUME button for at least 3-5 seconds.  
Test it at least once a week.  
Clean the Smoke/CO Alarm at least once a month; gently vacuum the  
outside of the Smoke/CO Alarm using your household vacuum’s soft  
brush attachment. A can of clean compressed air (sold at computer or  
office supply stores) may also be used. Follow manufacturer instructions  
for use. Test the Smoke/CO Alarm. Never use water, cleaners or solvents  
since they may damage the unit.  
After the Test/Silence or remote control button is released, the Red LED blinks  
during the silence mode.  
If the Alarm does not respond to your remote control, there may be an  
obstruction between you and the Alarm, you may be standing too far  
away, or your remote control may not be compatible.  
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust  
and/or grime, and cannot be cleaned to avoid unwanted alarms, replace  
the unit immediately.  
Relocate the unit if it sounds frequent unwanted alarms. See Where This  
Alarm Should Not Be Installed” for details.  
When the Smoke Alarm is Silenced  
When the CO Alarm is Silenced  
The Smoke Alarm will remain silent  
for up to 15 minutes, then return to  
normal operation.  
The CO alarm will remain silent for  
up to 4 minutes.  
Choosing a replacement battery:  
After 4 minutes, if CO levels remain  
potentially dangerous the horn will  
start sounding again.  
Your Smoke/CO Alarm requires two standard AA batteries. The following  
batteries are acceptable as replacements: Eveready Energizer E91. These  
batteries are available at many local retail stores.  
If the smoke has not cleared–or con-  
tinues to increase–the device will go  
back into alarm.  
Actual battery service life depends on the Smoke/CO Alarm and the environ-  
ment in which it is installed. All the batteries specified above are acceptable  
replacement batteries for this unit. Regardless of the manufacturer’s suggest-  
ed battery life, you MUST replace the battery immediately once the unit starts  
“chirping” (the “low battery warning).  
SILENCING THE LOW BATTERY WARNING  
This silence feature can temporarily quiet the low battery warning “chirp” for  
up to 8 hours. You can silence the low battery warning “chirp” two ways:  
1. Manually: Press the Test/Silence button on the alarm cover.  
To replace the batteries (without removing Alarm from the ceiling or wall):  
2. Using Your Remote Control: Standing no further than 20 feet (6 meters)  
away from the Smoke/CO Alarm, aim your IR remote at the Alarm and  
press the CHANNEL or VOLUME button for at least 3-5 seconds.  
1. Open the battery compartment.  
2. Press tabs A and B as shown in the diagram  
and remove each battery.  
Once the low battery warning “chirp” silence feature is activated, the unit  
continues to flash the Green light twice a minute for 8 hours. After 8 hours, the  
low battery “chirp” will resume. Replace the batteries as soon as possible;  
this unit will not operate without battery power!  
3. Insert the new batteries, making sure they  
snap completely into the battery compartment.  
B
Match the terminals on the ends of the  
batteries with the terminals on the unit.  
A
To deactivate this feature: Press the Test/Silence button or use your remote  
control again. The unit will go into Test Mode and the low battery warning will  
resume (LED flashes and unit sounds “chirp” once a minute).  
4. Close the battery compartment, and then test  
the unit by pressing the Test/Silence button or  
by using your remote control.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
A CO Alarm is not a substitute for proper maintenance of home appliances.  
To help prevent CO problems and reduce the risk of CO poisoning:  
WHAT YOU NEED TO KNOW ABOUT CO  
WHAT IS CO?  
Clean chimneys and flues yearly. Keep them free of debris, leaves, and  
nests for proper air flow. Also, have a professional check for rust and  
corrosion, cracks, or separations. These conditions can prevent proper  
air movement and cause backdrafting. Never “cap” or cover a chimney  
in any way that would block air flow.  
CO is an invisible, odorless, tasteless gas produced when fossil fuels do not  
burn completely, or are exposed to heat (usually fire). Electrical appliances  
typically do not produce CO.  
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline, kerosene,  
and propane.  
Common appliances are often sources of CO. If they are not properly main-  
tained, are improperly ventilated, or malfunction, CO levels can rise quickly. CO  
is a real danger now that homes are more energy efficient. “Air-tight” homes  
with added insulation, sealed windows, and other weatherproofing can trap”  
CO inside.  
Test and maintain all fuel-burning equipment annually. Many local gas  
or oil companies and HVAC companies offer appliance inspections for  
a nominal fee.  
Make regular visual inspections of all fuel-burning appliances. Check  
appliances for excessive rust and scaling. Also check the flame on the  
burner and pilot lights. The flame should be blue. A yellow flame means  
fuel is not being burned completely and CO may be present. Keep the  
blower door on the furnace closed. Use vents or fans when they are  
available on all fuel-burning appliances. Make sure appliances are  
vented to the outside. Do not grill or barbecue indoors, or in garages  
or on screen porches.  
SYMPTOMS OF CO POISONING  
These symptoms are related to CO POISONING and should be discussed  
with ALL household members.  
Mild Exposure: Slight headache, nausea, vomiting, fatigue (flu-like” symptoms).  
Medium Exposure: Throbbing headache, drowsiness, confusion, fast heart rate.  
Check for exhaust backflow from CO sources. Check the draft hood on  
an operating furnace for a backdraft. Look for cracks on furnace heat  
exchangers.  
Extreme Exposure: Convulsions, unconsciousness, heart and lung failure.  
Exposure to Carbon Monoxide can cause brain damage, death.  
Check the house or garage on the other side of shared wall.  
Keep windows and doors open slightly. If you suspect that CO is  
escaping into your home, open a window or a door. Opening windows  
and doors can significantly decrease CO levels.  
This CO Alarm measures exposure to CO over time. It alarms if CO levels are  
extremely high in a short period of time, or if CO levels reach a certain mini-  
mum over a long period of time. The CO Alarm generally sounds an alarm  
before the onset of symptoms in average, healthy adults. Why is this impor-  
tant? Because you need to be warned of a potential CO problem while you  
can still react in time. In many reported cases of CO exposure, victims may be  
aware that they are not feeling well, but become disoriented and can no  
longer react well enough to exit the building or get help. Also, young children  
and pets may be the first affected. The average healthy adult might not feel  
any symptoms when the CO Alarm sounds. However, people with cardiac or  
respiratory problems, infants, unborn babies, pregnant mothers, or elderly  
people can be more quickly and severely affected by CO. If you experience  
even mild symptoms of CO poisoning, consult your doctor immediately!  
In addition, familiarize yourself with all enclosed materials. Read this  
manual in its entirety, and make sure you understand what to do if your  
CO Alarm sounds.  
REGULATORY INFORMATION FOR  
SMOKE/CO ALARMS  
REGULATORY INFORMATION FOR CO ALARMS  
WHAT LEVELS OF CO CAUSE AN ALARM?  
FINDING THE SOURCE OF CO AFTER AN ALARM  
Carbon monoxide is an odorless, invisible gas, which often makes it difficult  
to locate the source of CO after an alarm. These are a few of the factors that  
can make it difficult to locate sources of CO:  
Underwriters Laboratories Inc. Standard UL2034 requires residential CO  
Alarms to sound when exposed to levels of CO and exposure times as  
described below. They are measured in parts per million (ppm) of CO over  
time (in minutes).  
House well ventilated before the investigator arrives.  
Problem caused by “backdrafting.”  
Transient CO problem caused by special circumstances.  
UL2034 Required Alarm Points*:  
If the alarm is exposed to 400 ppm of CO, IT MUST ALARM BETWEEN  
4 and 15 MINUTES.  
If the alarm is exposed to 150 ppm of CO, IT MUST ALARM BETWEEN  
10 and 50 MINUTES.  
If the alarm is exposed to 70 ppm if CO, IT MUST ALARM BETWEEN  
60 and 240 MINUTES.  
Because CO may dissipate by the time an investigator arrives, it may be  
difficult to locate the source of CO. BRK Brands, Inc. shall not be obligated  
to pay for any carbon monoxide investigation or service call.  
POTENTIAL SOURCES OF CO IN THE HOME  
* Approximately 10% COHb exposure at levels of 10% to 95% Relative  
Humidity (RH).  
Fuel-burning appliances like:  
portable heater, gas or wood  
burning fireplace, gas kitchen  
range or cooktop, gas clothes dryer.  
The unit is designed not to alarm when exposed to a constant level  
of 30 ppm for 30 days.  
Damaged or insufficient venting:  
corroded or disconnected water  
heater vent pipe, leaking chimney pipe  
or flue, or cracked heat exchanger,  
blocked or clogged chimney opening.  
CO Alarms are designed to alarm before there is an immediate life threat.  
Since you cannot see or smell CO, never assume it’s not present.  
An exposure to 100 ppm of CO for 20 minutes may not affect average,  
healthy adults, but after 4 hours the same level may cause headaches.  
An exposure to 400 ppm of CO may cause headaches in average, healthy  
adults after 35 minutes, but can cause death after 2 hours.  
Improper use of appliance/device:  
operating a barbecue grill or vehicle in  
an enclosed area (like a garage or  
screened porch).  
Standards: Underwriters Laboratories Inc. Single and Multiple Station carbon  
monoxide alarms UL2034.  
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2: “Carbon  
monoxide alarms covered by these requirements are intended to respond to  
the presence of carbon monoxide from sources such as, but not limited to,  
exhaust from internal-combustion engines, abnormal operation of fuel-fired  
appliances, and fireplaces. CO Alarms are intended to alarm at carbon  
monoxide levels below those that could cause a loss of ability to react to the  
dangers of Carbon Monoxide exposure.” This CO Alarm monitors the air at the  
Alarm, and is designed to alarm before CO levels become life threatening. This  
allows you precious time to leave the house and correct the problem. This is  
only possible if Alarms are located, installed, and maintained as described in  
this manual.  
Gas Detection at Typical Temperature and Humidity Ranges: The CO  
Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested  
for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane  
(500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon  
Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts  
per million.  
Transient CO Problems: transient” or on-again-off-again CO problems can  
be caused by outdoor conditions and other special circumstances.  
The following conditions can result in transient CO situations:  
1. Excessive spillage or reverse venting of fuel appliances caused by outdoor  
conditions such as:  
Wind direction and/or velocity, including high, gusty winds. Heavy air in  
the vent pipes (cold/humid air with extended periods between cycles).  
Negative pressure differential resulting from the use of exhaust fans.  
Several appliances running at the same time competing for limited  
fresh air.  
Vent pipe connections vibrating loose from clothes dryers, furnaces, or  
water heaters.  
Obstructions in or unconventional vent pipe designs which can amplify  
the above situations.  
2. Extended operation of unvented fuel burning devices (range, oven, fireplace).  
3. Temperature inversions, which can trap exhaust close to the ground.  
4. Car idling in an open or closed attached garage, or near a home.  
These conditions are dangerous because they can trap exhaust in your home.  
Since these conditions can come and go, they are also hard to recreate dur-  
ing a CO investigation.  
Audible Alarm: 85 dB minimum at 10 feet (3 meters).  
REGULATORY INFORMATION FOR SMOKE ALARMS  
RECOMMENDED LOCATIONS FOR SMOKE ALARMS  
Installing Smoke Alarms in Single-Family Residences  
The National Fire Protection Association (NFPA), recommends one Smoke  
Alarm on every floor, in every sleeping area, and in every bedroom. In new  
construction, the Smoke Alarms must be AC powered and interconnected.  
See “Agency Placement Recommendations” for details.  
HOW CAN I PROTECT MY FAMILY FROM  
CO POISONING?  
A CO Alarm is an excellent means of protection. It monitors the air and  
sounds a loud alarm before Carbon Monoxide levels become threatening for  
average, healthy adults.  
For additional coverage, it is recommended that you install a Smoke Alarm in  
all rooms, halls, storage areas, finished attics, and basements, where tempera-  
tures normally remain between 40˚ F (4˚ C) and 100˚ F (38˚ C). Make sure no  
door or other obstruction could keep smoke from reaching the Smoke Alarms.  
Continued...  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
More specifically, install Smoke Alarms:  
ABOUT SMOKE ALARMS  
Battery (DC) operated Smoke Alarms: Provide protection even when  
electricity fails, provided the batteries are fresh and correctly installed. Units  
are easy to install, and do not require professional installation.  
On every level of your home, including finished attics and basements.  
Inside every bedroom, especially if people sleep with the door partly or  
completely closed.  
In the hall near every sleeping area. If your home has multiple sleeping  
areas, install a unit in each. If a hall is more than 40 feet long (12 meters),  
install a unit at each end.  
At the top of the first-to-second floor stairway, and at the bottom  
of the basement stairway.  
AC powered Smoke Alarms: Can be interconnected so if one unit senses  
smoke, all units alarm. They do not operate if electricity fails.  
AC with battery (DC) back-up: will operate if electricity fails, provided the  
batteries are fresh and correctly installed. AC and AC/DC units must be  
installed by a qualified electrician.  
Smoke/CO Alarms for Solar or Wind Energy users and battery backup  
power systems: AC powered Smoke/CO Alarms should only be operated  
with true or pure sine wave inverters. Operating this Alarm with most battery-  
powered UPS (uninterruptible power supply) products or square wave or  
“quasi sine wave” inverters will damage the Alarm. If you are not sure about  
your inverter or UPS type, please consult with the manufacturer to verify.  
Specific requirements for Smoke Alarm installation vary from state to state  
and from region to region. Check with your local Fire Department for current  
requirements in your area. It is recommended AC or AC/DC units be  
interconnected for added protection.  
Smoke Alarms for the hearing impaired: Special purpose Smoke Alarms  
should be installed for the hearing impaired. They include a visual alarm and  
an audible alarm horn, and meet the requirements of the Americans With  
Disabilities Act. Can be interconnected so if one unit senses smoke, all units  
alarm.  
Smoke alarms are not to be used with detector guards unless the  
combination has been evaluated and found suitable for that purpose.  
All these Smoke Alarms are designed to provide early warning of fires if  
located, installed and cared for as described in the user’s manual, and if  
smoke reaches the Alarm. If you are unsure which type of Smoke Alarm to  
install, refer the National Fire Protection Association (NFPA) Standard 72  
(National Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire  
Protection Association, One Batterymarch Park, Quincy, MA 02269-9101.  
Local building codes may also require specific units in new construction or  
in different areas of the home.  
SPECIAL COMPLIANCE CONSIDERATIONS  
INSTALLING SMOKE ALARMS IN MOBILE HOMES  
For minimum security install one Smoke Alarm as close to each sleeping area as  
possible. For more security, put one unit in each room. Many older mobile homes  
(especially those built before 1978) have little or no insulation. If your mobile  
home is not well insulated, or if you are unsure of the amount of insulation, it is  
important to install units on inside walls only. Smoke Alarms should be installed  
where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F (38˚ C).  
This unit alone is not a suitable substitute for complete fire detection  
systems in places housing many people—like apartment buildings,  
condominiums, hotels, motels, dormitories, hospitals, long-term health  
care facilities, nursing homes, day care facilities, or group homes of any  
kind—even if they were once single-family homes. It is not a suitable  
substitute for complete fire detection systems in warehouses, industrial  
facilities, commercial buildings, and special-purpose non-residential  
buildings which require special fire detection and alarm systems.  
Depending on the building codes in your area, this unit may be used to  
provide additional protection in these facilities.  
AGENCY PLACEMENT RECOMMENDATIONS  
This equipment should be installed in accordance with NFPA (National Fire  
Protection Association) 72 and 101. National Fire Protection Association,  
One Batterymarch Park, Quincy, MA 02269-9101. Additional local building  
and regulatory codes may apply in your area. Always check compliance  
requirements before beginning any installation.  
Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke  
Alarms 217.  
The following information applies to all five types of buildings listed below:  
In new construction, most building codes require the use of AC or AC/DC  
powered Smoke Alarms only. AC, AC/DC, or DC powered Smoke Alarms can be  
used in existing construction as specified by local building codes. Refer to NFPA  
72 (National Fire Alarm Code) and NFPA 101 (Life Safety Code), local building  
codes, or consult your Fire Department for detailed fire protection requirements  
in buildings not defined as “households.”  
NFPA 72 (National Fire Code)  
Smoke Alarms shall be installed in each separate sleeping room, outside each  
sleeping area in the immediate vicinity of the bedrooms and on each additional  
story of the family living unit, including basements and excluding crawl spaces  
and unfinished attics.  
In new construction, Alarms shall be so arranged that operation of any one Alarm  
shall cause the operation of all Alarms within the dwelling.  
1. Single-Family Residence:  
Single family home, townhouse. It is recommended this unit be installed on  
every level of the home, in every bedroom, and in each bedroom hallway.  
2. Multi-Family or Mixed Occupant Residence:  
Apartment building, condominium. This unit is suitable for use in individual  
apartments or condos, provided a primary fire detection system already exists  
to meet fire detection requirements in common areas like lobbies, hallways, or  
porches. Using this unit in common areas may not provide sufficient warning  
to all residents or meet local fire protection ordinances/regulations.  
Smoke Detection-Are More Smoke Alarms Desirable? The required number  
of Smoke Alarms might not provide reliable early warning protection for those  
areas separated by a door from the areas protected by the required Smoke  
Alarms. For this reason, it is recommended that the householder consider the  
use of additional Smoke Alarms for those areas for increased protection. The  
additional areas include the basement, bedrooms, dining room, furnace room,  
utility room, and hallways not protected by the required Smoke Alarms. The  
installation of Smoke Alarms in kitchens, attics (finished or unfinished), or  
garages is not normally recommended, as these locations occasionally experi-  
ence conditions that can result in improper operation.  
3. Institutions:  
Hospitals, day care facilities, long-term health care facilities. This unit is  
suitable for use in individual patient sleeping/resident rooms, provided a  
primary fire detection system already exists to meet fire detection require-  
ments in common areas like lobbies, hallways, or porches. Using this unit in  
common areas may not provide sufficient warning to all residents or meet  
local fire protection ordinances/regulations.  
California State Fire Marshal (CSFM)  
Early warning detection is best achieved by the installation of fire detection  
equipment in all rooms and areas of the household as follows: A Smoke Alarm  
installed in each separate sleeping area (in the vicinity, but outside bedrooms),  
and Heat or Smoke Alarms in the living rooms, dining rooms, bedrooms,  
kitchens, hallways, finished attics, furnace rooms, closets, utility and storage  
rooms, basements, and attached garages.  
4. Hotels and Motels:  
Also boarding houses and dormitories. This unit is suitable for use inside  
individual sleeping/resident rooms, provided a primary fire detection system  
already exists to meet fire detection requirements in common areas like  
lobbies, hallways, or porches. Using this unit in common areas may not  
provide sufficient warning to all residents or meet local fire protection  
ordinances/regulations.  
5. Warehouses/Commercial Buildings:  
DO NOT use this Smoke/CO Alarm in warehouses, industrial or commercial  
buildings, special-purpose non-residential buildings, RVs, boats, or airplanes.  
This Smoke/CO Alarm is specifically designed for residential use, and may not  
provide adequate protection in non-residential applications.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL LIMITATIONS OF SMOKE/CO ALARMS  
not give adequate early warning. Recommended minimum protection is one  
This Smoke/CO Alarm is intended for residential use. It is not intended for use  
in industrial applications where Occupational Safety and Health Administration  
(OSHA) requirements for Carbon Monoxide Alarms must be met. The Smoke  
Alarm portion of this device is not intended to alert hearing impaired resi-  
dents. Special purpose Smoke Alarms should be installed for hearing impaired  
residents (CO Alarms are not yet available for the hearing impaired).  
Smoke/CO Alarms may not waken all individuals. Practice the escape plan  
at least twice a year, making sure that everyone is involved – from kids to  
grandparents. Allow children to master fire escape planning and practice  
before holding a fire drill at night when they are sleeping. If children or others  
do not readily waken to the sound of the Smoke/CO Alarm, or if there are  
infants or family members with mobility limitations, make sure that someone  
is assigned to assist them in fire drill and in the event of an emergency. It is  
recommended that you hold a fire drill while family members are sleeping in  
order to determine their response to the sound of the Smoke/CO Alarm while  
sleeping and to determine whether they may need assistance in the event of  
an emergency.  
Smoke/CO Alarms cannot work without power. Battery operated units cannot  
work if the batteries are missing, disconnected or dead, if the wrong type of  
batteries are used, or if the batteries are not installed correctly. AC units cannot  
work if the AC power is cut off for any reason (open fuse or circuit breaker, failure  
along a power line or at a power station, electrical fire that burns the electrical  
wires, etc.). If you are concerned about the limitations of battery or AC power,  
install both types of units.  
alarm device in every sleeping area, every bedroom, and on every level of your  
home. Some experts recommend battery powered Smoke and CO Alarms be  
used in conjunction with interconnected AC powered Smoke Alarms. For  
details, see “About Smoke Alarms” for details.  
Smoke/CO Alarms may not be heard. The alarm horn loudness meets or  
exceeds current UL standards of 85 dB at 10 feet (3 meters). However, if the  
Smoke/CO Alarm is installed outside the bedroom, it may not wake up a  
sound sleeper or one who has recently used drugs or has been drinking  
alcoholic beverages. This is especially true if the door is closed or only partly  
open. Even persons who are awake may not hear the alarm horn if the sound  
is blocked by distance or closed doors. Noise from traffic, stereo, radio,  
television, air conditioner, or other appliances may also prevent alert persons  
from hearing the alarm horn. This Smoke/CO Alarm is not intended for people  
who are hearing impaired.  
The Alarm may not have time to alarm before the fire itself causes  
damage, injury, or death, since smoke from some fires may not reach  
the unit immediately. Examples of this include persons smoking in bed,  
children playing with matches, or fires caused by violent explosions  
resulting from escaping gas.  
This Smoke/CO Alarm is not a substitute for life insurance. Though this  
Smoke/CO Alarm warns against increasing CO levels or the presence of  
smoke, BRK Brands, Inc. does not warrant or imply in any way that they will  
protect lives. Homeowners and renters must still insure their lives.  
This Smoke/CO Alarm will not sense smoke or CO that does not reach  
the sensors. It will only sense smoke or CO at the sensor. Smoke or CO may  
be present in other areas. Doors or other obstructions may affect the rate at  
which CO or smoke reaches the sensors. If bedroom doors are usually closed  
at night, we recommend you install an alarm device (Combination CO and  
Smoke Alarm, or separate CO Alarms and Smoke Alarms) in each bedroom  
and in the hallway between them.  
This Smoke/CO Alarm may not sense smoke or CO on another level of  
the home. Example: This alarm device, installed on the second floor, may not  
sense smoke or CO in the basement. For this reason, one alarm device may  
This Smoke/CO Alarm has a limited life. Although this Smoke/CO Alarm  
and all of its parts have passed many stringent tests and are designed to be  
as reliable as possible, any of these parts could fail at any time. Therefore, you  
must test this device weekly. The unit should be replaced immediately if it is  
not operating properly.  
This Smoke/CO Alarm is not foolproof. Like all other electronic devices, this  
Smoke/CO Alarm has limitations. It can only detect smoke or CO that reaches  
the sensors. It may not give early warning of the source of smoke or CO is in a  
remote part of the home, away from the alarm device.  
TROUBLESHOOTING GUIDE  
If the Alarm...  
Problem...  
You should...  
Horn "chirps" about once per minute;  
Voice: "Replace battery in [Location]" every 5 hours  
Low battery warning.  
Install two new AA batteries*.  
Horn does three rapid "chirps" every minute;  
Voice: "Detector error in [Location, example  
"Kitchen"], please see manual" repeated every 5  
hours; LED has 3 rapid flashes with "chirps".  
Device is not working properly, and needs to be  
replaced.  
Units under warranty should be returned to  
manufacturer for replacement. See “Limited  
Warranty” for details.  
Carbon Monoxide Alarm ONLY:  
CO Alarm goes back into alarm 4 minutes after you  
Silence it.  
CO levels indicate a potentially dangerous situation.  
IF YOU ARE FEELING SYMPTOMS OF CO  
POISONING, EVACUATE your home and call 911  
or the Fire Department. Refer to "If The CO Alarm  
Sounds" for details.  
CO Alarm sounds frequently even though no high  
levels of CO are revealed in an investigation.  
The CO Alarm may be improperly located. Refer to  
Where to Install This Alarm” for details.  
Relocate your Alarm. If frequent alarms continue,  
have home rechecked for potential CO problems.  
You may be experiencing an intermittent CO  
problem.  
Smoke Alarm ONLY:  
Smoke Alarm sounds when no smoke is visible.  
Unwanted alarm may be caused by non-emergency  
source like cooking smoke.  
Silence Alarm using remote control or manual  
button; clean the Alarm’s cover with a soft, clean  
cloth. If frequent unwanted alarms continue, relocate  
your Alarm. Alarm may be too close to a kitchen,  
cooking appliance, or steamy bathroom.  
*For a list of acceptable replacement batteries, see “Regular Maintenance.”  
If you have questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005, M-F 7:30 a.m. to 5:00 p.m. (CST)  
LIMITED WARRANTY  
BRK Brands, Inc., ("BRK") the maker of First Alert® brand products warrants that for a period of five years from the date of purchase, this product will be free from  
defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty  
period. Replacement will be made with a new or remanufactured product or component. If the product is no longer available, replacement may be made with a similar  
product of equal or greater value. This is your exclusive warranty.  
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt. Proof of purchase is  
required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to alter, modify or any way change  
the terms and conditions of this warranty.  
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper voltage or  
current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center. Further, the warranty  
does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.  
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent prohibited by  
applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above warranty. Some states,  
provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the  
above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state or  
province to province.  
How to Obtain Warranty Service  
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at 1-800-323-9005,  
7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and date of purchase available when  
calling. 303 Nelson Avenue, Neosho, MO 64850-8806.  
Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose with respect  
to battery.  
First Alert® is a registered trademark of the First Alert Trust.  
Printed in Mexico M08-0048-005 06/06  
For your records, please record:  
Date Purchased: _________________ Where Purchased: ___________________________  
7
Q
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eton Portable Radio Mini300PE User Manual
Fluke Computer Monitor A20M AF User Manual
Ford Automobile 2011 Crown Victoria User Manual
Fostex DJ Equipment MN 50 User Manual
Fujitsu Scanner FI 4220C User Manual
GarrettCom Switch 6KQE User Manual
Gemini Music Mixer iTrax User Manual
GE Monogram Ventilation Hood ZXR8510 User Manual
Gigabyte Computer Hardware GA 8I915GM User Manual
Global Upholstery Co Patio Furniture 3342 Midtown User Manual