Extron electronic Switch ECP 1000 User Manual

User’s Manual  
ECP 1000  
Event Control Panel  
Extron Electronics, USA  
1230 South Lewis Street  
Anaheim, CA 92805  
USA  
714.491.1500  
Fax 714.491.1517  
Extron Electronics, Europe  
Beeldschermweg 6C  
3821 AH Amersfoort  
The Netherlands  
+31.33.453.4040  
Fax +31.33.453.4050  
Extron Electronics, Asia  
135 Joo Seng Road, #04-01  
PM Industrial Building  
Singapore 368363  
+65.6383.4400  
Fax +65.6383.4664  
Extron Electronics, Japan  
Daisan DMJ Building 6F  
3-9-1 Kudan Minami  
Chiyoda-ku, Tokyo 102-0074 Japan  
+81.3.3511.7655  
68-518-01  
Printed in the USA  
Fax +81.3.3511.7656  
© 2002 Extron Electronics. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents, cont’d  
ECP 1000 Event Control Panel  
Chapter One  
1
Introduction  
Features  
ECP 1000 • Table of Contents  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
The Extron ECP 1000 event control panel attaches to as many as  
ECP 1000 Event Control Panel  
three Extron SGS 408 seamless switchers to provide complete  
control of multiple screens in large staging applications. The  
ECP 1000 allows you to create simultaneous or synchronous  
wipes, dissolves, fades, and cuts on any combination of the  
attached screens.  
The ECP 1000 includes pre-programmed effects that are  
available at the touch of a single button. In addition, the  
SGS 408 Control Program for Windows allows you to select  
effects for each screen so you can create your own preset series  
of effects.  
Features  
Pre-programmed effects — The effect buttons initiate multi-  
screen effects. There are 40 user-programmable presets,  
30 of which are pre-programmed at the factory. The  
SGS 408 Control Program for Windows allows you to  
overwrite all preset button settings.  
Show sequencing — Using the SGS 408 Control Program for  
Windows, you can create a series of effects that are  
initiated sequentially at the touch of a single effect  
selection button.  
Chapter Two  
2
Button label software — Some buttons are labeled with a  
pictorial example of their associated effects. You can  
create labels for unlabeled buttons, or you can replace  
existing labels to match any changes you have made to  
button assignments.  
Installation  
Effect selection buttons — These buttons allow you to create  
wipes, dissolves, and title effects.  
Screen selection buttons — These buttons allow you to choose  
RearPanelFeatures  
Installation  
the screen or screens on which an effect will appear.  
Duration adjustment — This control allows you to specify the  
length of time in which each effect occurs.  
T-bar controller — This control allows you to manually control  
the speed of a transition.  
ECP 1000 • Introduction  
1-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Rear Panel Features  
Continue the procedure for installing the SGS 408.  
5
6
Attach power cords and plug the SGS 408 seamless  
switcher, ECP 1000 event control panel, input devices, and  
output devices into a grounded AC source.  
Select an input from the front panel buttons on the  
SGS 408 switcher or RCP 1000 remote control unit.  
7
8
The image should now appear. If not, ensure that all  
devices are plugged in and receiving power. Check the  
cabling and make adjustments as needed. Select a  
different input to check for a display.  
TO SGS  
2
3
1
PROGRAM  
100-240V  
50/60 Hz 0.5A  
1
2
3
4
Figure 2-1 — ECP 1000 rear panel  
AC power connector — One standard AC power connector  
attaches the event control panel to any power source from  
100VAC to 240VAC, operating at 50 or 60 Hz.  
1
2
3
4
Projectors  
Cooling fan — One fan cools the ECP 1000 unit. The filter can  
be removed and washed as needed. See page A-2 for  
instructions.  
RS-232/program connector — One 9-pin D female connector  
allows you to communicate with Extron’s SGS 408 Control  
Program.  
SGS 408  
T
N
C
T
N
C
T
N
O
F
E
C
I
T
I
O
F
F
E
I
O
F
F
E
I
R
R
T
R
A
N
S
IT  
E
T
F
N
S
E
T
N
S
I
T
E
A
A
SGS 408  
N
8
I
P
U
T
T
P
U
N
P
U
T
N
4
0
8
I
8
I
4
0
4
0
S
S
S
G
C
S
C
I
T
I
T
H
E
R
G
E
R
G
E
R
S
H
S
H
S
M
W
I
T
A
M
W
C
A
M
W
R
A
C
S
S
A
G
R
C
S
S
A
G
R
C
N
S
I
P
V
G
R
A
A
T
N
S
P
E
V
G
R
A
A
T
N
S
P
P
R
E
V
G
R
A
P
H
I
O
N
T
S
A
K
E
O
R
G
E
W
H
I
T
I
O
N
T
K
E
O
R
W
H
I
T
I
O
N
T
K
E
O
W
T
I
R
P
I
E
P
I
R
P
I
E
P
I
R
I
E
A
T
R
U
R
U
T
C
R
U
S
S
T
C
S
S
T
C
E
T
E
T
E
T
P
U
T
U
T
S
P
U
T
S
S
E
A
M
L
A
T
M
L
E
R
A
A
M
L
E
R
A
E
S
S
R
E
A
E
P
T
O
U
T
O
U
U
8
8
8
T
T
2
4
7
2
4
7
2
4
7
F
E
E
F
1
1
6
5
5
6
5
6
A
M
4
R
A
M
4
R
A
M
4
P
R
O
G
O
G
R
R
O
G
P
R
P
3
3
3
3
3
2
2
2
8
8
1
1
1
7
7
8
7
C
K
N
A
C
K
N
A
C
K
L
A
I
B
L
O
B
L
O
N
I
B
6
6
T
I
6
A
C
A
T
I
Z
E
N
I
E
Z
E
I
C
E
Z
E
E
U
E
U
N
E
U
N
M
M
F
R
E
5
x
M
R
5
M
x
F
R
C
T
C
T
C
x
P
C
P
P
T
R
C
R
W
C
I
E
W
4
x
I
E
W
4
x
I
E
4
5
E
V
R
R
E
V
R
E
V
R
x
P
R
P
P
R
3
3
3
2
2
2
1
1
1
C
L
B
L
A
B
L
A
C
K
B
R
F
F
E
E
Z
E
SGS 408  
Z
E
E
Z
E
E
E
R
E
R
F
RS-232/SGS 408 connectors — Three 9-pin D female connectors  
allow you to attach an ECP 1000 event control panel to up to  
three SGS 408 seamless switchers. The connectors correspond to  
the screen selection buttons on the ECP 1000’s top panel.  
Program  
Monitor  
Program  
Monitor  
Preview  
Monitor  
Preview  
Monitor  
Program  
Monitor  
S
O
N
T
I
N
S
I
T
R
A
T
S
E
C
F
F
8
7
6
5
0
ECP 1000  
A
M
00  
L
E
N
Preview  
Monitor  
R
4
8
1
G
O
P
A
P
P
R
C
L
O
R
3
7
x
I
O
N
R
T
C
A
T
T
N
O
x
N
I
R
U
M
C
2
6
O
M
T
E
O
C
M
E
R
1
5
W
A
C
K
E
V
R
I
E
4
Up to 50'  
L
B
P
P
Z
E
3
F
R
E
E
2
T
U
S
A
D
J
0
0
1
0
L
1
E
P
A
N
A
C
K
C
L
O
P
B
L
E
N
F
R
E
E
Z
E
T
R
O
C
T
N
E
T
E
R
V
E
E
N
C
E
I
Z
E
R
I
G
B
R
H
T
S
T
I
L
O
N
D
/
F
C
Z
H
O
R
I
IT  
O
H
T
R
T
N
S
V
E
B
N
S
T
R
A
C
O
N
T
E
C
F
8
7
Installation  
6
5
0
0
M
0
L
E
A
R
4
8
1
G
N
A
P
O
P
P
R
C
L
O
R
x
I
O
N
R
3
T
A
T
x
N
I
C
T
N
O
R
U
M
C
2
6
7
O
M
T
E
O
C
M
E
R
1
5
W
Control Room  
A
C
K
E
V
I
E
4
B
L
R
P
E
P
E
3
F
R
E
2
1
C
K
B
L
E
E
Z
F
R
E
R
T
E
C
E
N
E
H
T
S
I
Z
T
E
R
I
G
B
R
I
L
O
N
D
/
F
C
Z
H
O
R
N
V
E
B
R
G
H
T
T
S
R
To install and set up the ECP 1000, follow these steps:  
I
T
I
O
N
S
T
R
A
O
T
C
E
C
F
F
8
7
6
5
0
0
M
A
0
L
E
N
R
4
8
1
G
O
P
A
P
P
R
C
L
O
R
3
7
T
x
I
O
N
R
x
N
I
C
A
T
T
N
O
R
U
M
C
2
6
O
M
T
E
O
C
M
E
R
1
5
A
C
K
E
P
R
V
I
E
W
4
B
L
P
Z
E
3
F
R
E
2
1
C
K
B
L
A
E
E
Z
F
R
E
R
RCP 1000  
E
N
T
E
C
E
S
I
Z
T
E
R
R
I
G
H
T
F
I
L
/
B
N
D
Mount the SGS 408 switcher(s) as described in the SGS 408  
User’s Manual (Extron part number 68-520-01).  
C
O
1
Z
H
O
R
V
E
B
H
T
R
T
T
C
N
Set the ECP 1000 on a flat surface.  
2
3
For each SGS 408 to which the ECP 1000 will be connected,  
attach an ECP comm cable (provided with the SGS 408)  
between an SGS connector on the ECP 1000 and the RS-232  
connector on the SGS 408. Figure 2-2 shows a typical  
application.  
Figure 2-2 — SGS 408 and ECP 1000 application  
If desired, attach a host computer or other control device  
to the RS-232/program connector.  
4
ECP 1000 • Installation  
2-2  
ECP 1000 • Installation  
2-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation, cont’d  
ECP 1000 Event Control Panel  
Chapter Three  
3
Operation  
Top Panel Controls  
Power-up  
Using the Menus  
Applying a Switch  
ECP 1000 • Installation  
2-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
Top Panel Controls  
Dissolve button — Allows you to set up a dissolving switch.  
See “Applying a dissolve” on page 3-7 for more information.  
7
8
1
2
3
4
5
6
7
8
9
Title button — Allows you to set up a title switch. See  
“Applying a title” on page 3-7 for more information.  
Take button — Initiates the switch selected by the effect  
buttons.  
9
CUT  
DISSOLVE  
SCREEN  
TITLE  
T-bar controller — Allows you to override the duration of an  
effect. See step 4 in “Applying a title” on page 3-8 or step 5 in  
“Applying a wipe” on page 3-10.  
10  
1
2
3
10  
SOFT  
EDGE  
TAKE  
Adjustment knob — Allows you to make adjustments to the  
menu selections (see “Using the Menus” on page 3-4) and to  
change the duration of an effect (see “Applying a Switch” on  
page 3-6.  
11  
ADJUST  
MENU  
NEXT  
11  
ECP 1000  
LCD screen — Displays status information and menu screens.  
12  
13  
EVENT CONTROL PANEL  
Next button — Steps through LCD screens within a menu. See  
14  
13 12  
“Using the Menus” on page 3-4.  
Figure 3-1 — ECP 1000 top panel  
Menu button — Steps through LCD menus. See “Using the  
14  
Menus” on page 3-4.  
One-screen effect buttons — Allow you to specify the effects for  
one screen. All of the buttons are user-programmable.  
1
2
Power-up  
Two-screen effect buttons — Allow you to specify the effects  
for two screens. The buttons in the two right columns are pre-  
programmed. All of the buttons are user-programmable.  
When the ECP 1000 is powered up, the following events occur:  
• All lights on the ECP 1000 front panel turn on and then off, in  
sequence.  
Three-screen effect buttons — Allow you to specify the effects  
for three screens. The buttons in the two right columns are pre-  
programmed. All of the buttons are user-programmable.  
3
• The ECP 1000 detects the number of SGS 408 units that are  
connected.  
• The buttons that are programmed to work with the number of  
connected SGS 408 units become backlit. For example, if  
SGS 408 units are attached to SGS ports 1 and 3, all screen  
effect buttons that are programmed to work with 1 or 2  
screens become backlit, as do screen selection buttons 1  
and 3.  
The names “one-screen”, “two-screen”, and “three-  
screen” are not absolutes. You can program a one-screen  
effect into a three-screen effect button. The names are  
used only to identify the particular set of buttons.  
Soft edge button — Allows you to select whether single-  
dimension wipes will have hard or soft edges.  
4
5
6
• The LCD displays the name of the product, and then displays  
the attached screens (based on the connected ports) and  
the default effect duration (figure 3-2). This second screen  
is the default screen.  
Screen selection buttons — Allow you to choose the screen on  
which effects, cuts, dissolves, and titles will take place.  
Cut button — Initiates an immediate seamless switch between  
the program and preview images. See “Applying a cut” on page  
3-6 for more information.  
EXTRON  
ECP-1000  
SGS 1  
1.0 SEC  
.
3
Figure 3-2 — Power-up screens  
ECP 1000 • Operation  
3-2  
ECP 1000 • Operation  
3-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation, cont’d  
In the display of attached screens, a dot represents a  
screen that is not attached.  
Performing a system reset  
A system reset returns all settings to their factory defaults. It  
removes all user-programmed effects, and returns pre-  
programmed effect buttons to their original effects. It also  
cancels the screen selection button settings.  
Using the Menus  
The ECP 1000 menus allow you to do the following:  
• Change the backlight intensity (see below).  
• Perform a system reset (see page 3-5).  
To perform a system reset, do the following:  
1.  
From the default screen, press the Menu button twice. The  
System Reset menu appears (figure 3-4).  
• Program the ECP 1000 (see page 3-5).  
Press  
Menu  
button  
Press  
Menu  
button  
Press  
Menu  
button  
Changing the backlight intensity  
SGS 1  
1.0 SEC  
.
3
BACK  
LIGHT  
SYSTEM  
RESET  
PROGRAM  
MODE  
The buttons on the top panel of the ECP 1000 are backlit to  
make them easier to see in rooms with low-level lighting. You  
can control the amount of light the buttons emit by doing the  
following:  
Press  
Menu  
button  
Press  
Next  
button  
Press  
Next  
button  
(System  
(System  
reset  
reset  
does  
not  
occurs)  
Press Take button  
1.  
From the default screen, press the Menu button. The Back  
Light menu appears (figure 3-3).  
TAKE TO  
CONFIRM  
occur)  
Press Menu button twice  
Press  
Menu  
button  
Press  
Menu  
button  
Figure 3-4 — Performing a system reset  
SGS 1 . 3  
1.0 SEC  
BACK  
LIGHT  
SYSTEM  
RESET  
2.  
3.  
Press the Next button. The Take to Confirm menu  
appears.  
Press  
Next  
button  
Press  
Next  
button  
Do one of the following:  
To confirm the system reset, press the Take button.  
The system reset occurs, and the default screen  
appears.  
Press  
Press  
Menu  
button  
INTENSITY  
20%  
Menu  
button  
three  
times  
Rotate  
Adjust  
knob  
To cancel the system reset and exit the LCD menu,  
press the Menu button twice. The default screen  
appears.  
INTENSITY  
30%  
To proceed to the Program Mode menu, press the  
Menu button once.  
Figure 3-3 — Changing the backlight  
Programming the ECP 1000  
2.  
3.  
Press the Next button. The Intensity screen appears.  
When the ECP 1000 is in program mode, it cannot  
control effects on the SGS 408.  
Rotate the Adjust knob until the backlight is at the desired  
intensity.  
The SGS 408 Control Program allows you to program the  
ECP 1000. Before the software can communicate with the  
ECP 1000, the ECP 1000 must be in program mode. To enter  
program mode, do the following:  
4.  
Do one of the following:  
To exit the LCD menu, press the Menu button three  
times. The default screen appears.  
1.  
From the default screen, press the Menu button three  
times. The Program Mode menu appears (figure 3-5 on  
the next page).  
To proceed to the System Reset menu, press the  
Menu button once.  
To return to the Back Light menu, press the Next  
button once.  
ECP 1000 • Operation  
3-4  
ECP 1000 • Operation  
3-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation, cont’d  
Press Menu button  
Applying a dissolve  
A dissolve causes the program image to fade out while the  
preview image fades in (figure 3-6).  
Press  
Menu  
button  
Press  
Menu  
button  
Press  
Menu  
button  
SGS 1  
1.0 SEC  
.
3
BACK  
LIGHT  
SYSTEM  
RESET  
PROGRAM  
MODE  
Dissolve  
Dissolve  
Press  
Next  
button  
Figure 3-6 — A dissolve effect  
Use the SGS 408 Control Program.  
When finished, press Menu button.  
PROGRAM  
*READY*  
To switch using a dissolve, do the following:  
1.  
2.  
Press the Dissolve button.  
Figure 3-5 — Programming the ECP 1000  
Press the screen selection buttons that correspond to the  
screens you want to switch. For example, if you want to  
apply the dissolve to screen 2, press screen selection  
button 2. If you want to apply the dissolve to screens 1  
and 3, press screen selection buttons 1 and 3.  
2.  
3.  
Press the Next button. The Program Ready menu  
appears.  
Do one of the following:  
To program the ECP 1000, use the SGS 408 Control  
Program. See chapter 4 for information. When you  
are finished using the program, press the Menu  
button. The default screen appears.  
You can select a screen selection only if it is backlit.  
3.  
4.  
If you want to use a duration other than the default  
duration, turn the Adjust knob until the desired duration  
appears on the LCD menu’s default screen.  
To exit the LCD menu without programming the  
ECP 1000, press the Menu button.  
Press the Take button. The dissolving switch begins  
immediately and is finished in the time specified by the  
duration, and the preview image becomes the new  
program image.  
Applying a Switch  
You can switch displays using a variety of techniques. For a  
description of each technique, see the instructions for the  
technique in this section.  
Applying a title  
A title can have two effects: window or key. The actual effect is  
determined by the ECP title setting on the SGS 408 (see chapter  
Applying a cut  
3 of the SGS 408 User’s Manual).  
A cut seamlessly replaces the program image with the preview  
image. No effect is applied to the switch. As soon as the Take  
button is pressed, the switch occurs.  
A title window causes a predefined box in the program image to  
dissolve to reveal the preview image (figure 3-7). The effect is  
as if the preview image were located behind the program  
image, and a window in the program image opens to show the  
preview image.  
To switch using a cut, do the following:  
1.  
2.  
Press the Cut button.  
Press the screen selection buttons that correspond to the  
screens you want to switch. For example, if you want to  
apply the cut to screen 2, press screen selection button 2. If  
you want to apply the cut to screens 1 and 3, press screen  
selection buttons 1 and 3.  
Figure 3-7 — A title window effect example  
You can select a screen selection only if it is backlit.  
3.  
Press the Take button. The seamless switch takes effect  
immediately, and the preview image becomes the new  
program image.  
A title key causes any portion of the preview image which is  
over half intensity (.35V) to be displayed with the program  
image.  
ECP 1000 • Operation  
3-6  
ECP 1000 • Operation  
3-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation, cont’d  
When the either title effect ends, the preview image disappears,  
and the program image is again intact.  
To apply a title, do the following:  
left to right  
right to left  
top to bottom  
bottom to top  
1.  
2.  
Press the Title button.  
Figure3-8Standardwipetransitions  
Press the screen selection buttons that correspond to the  
screens you want to switch. For example, if you want to  
apply the title to screen 2, press screen selection button 2.  
If you want to apply the title to screens 1 and 3, press  
screen selection buttons 1 and 3.  
• A curtain wipe causes the preview image to appear to unroll  
over the program image in two directions  
simultaneously. The preview image can wipe across the  
program image with the following transitions (figure 3-9):  
You can select a screen selection only if it is backlit.  
In from the left and right edges of the screen to the  
center of the screen  
3.  
4.  
If you want to use a duration other than the default  
duration, turn the Adjust knob until the desired duration  
appears on the LCD menu’s default screen.  
Out from the center of the screen to the left and right  
edges of the screen  
Do one of the following.  
In from the top and bottom of the screen to the  
center of the screen  
Press the Take button. During the time specified by  
the duration, the selected portion of the program  
image dissolves away to be replaced by the preview  
image. The Take button remains lit, and the Title  
button flashes.  
Out from the center of the screen to the top and  
bottom of the screen  
When you want to end the title, press the Take button  
again.  
Figure 3-9 — Curtain wipe effects  
Move the T-bar control. The title appears and  
remains until you move the T-bar to the opposite end  
point of the t-bar slot. Or, you could stop moving the  
T-bar and press the Take button, in which case the  
title is completed during the remaining duration  
time.  
• A plus wipe causes the preview image to appear to unroll over  
the program image in one of two transitions (figure 3-10):  
Starting in all four corners of the screen and moving  
in to the center of the screen  
Starting in the center of the screen and moving out to  
the corners of the screen  
Wipes  
A wipe causes the preview image to replace the program image  
in any one of many directions.  
• A standard wipe causes the preview image to appear to unroll  
over the program image horizontally or vertically. By  
default, the wipe has hard edges. The preview image can  
wipe across the program image with the following  
transitions (figure 3-8):  
Figure 3-10 — Plus wipe effects  
• A square wipe causes the preview image to appear to unroll  
over the program image in one of two transitions  
(figure 3-11):  
From left to right  
From right to left  
From top to bottom  
From bottom to top  
Starting at all four edges of the screen and moving in  
to the center of the screen  
Starting in the center of the screen and moving out to  
the edges of the screen  
ECP 1000 • Operation  
3-8  
ECP 1000 • Operation  
3-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation, cont’d  
Move the T-bar control. The wiping switch takes  
place until you move the T-bar to the opposite end  
point of the t-bar slot. Or, you could stop moving the  
T-bar and press the Take button, in which case the  
switch is completed during the remaining duration  
time. Regardless of the method, the LCD displays  
the percentage count as described in the previous  
paragraph.  
Figure 3-11 — Square wipe effects  
Applying a wipe  
To apply a wipe, do the following:  
During a wipe, you can reverse the direction of the  
wipe (in effect, “unwipe” the program image) by  
reversing the direction of the T-bar control. This is  
true until the T-bar reaches the end point of the T-bar  
slot, in which case the effect is considered completed.  
1.  
Press the effect button that is programmed to perform the  
wipe you want.  
2.  
If this is the first time any effect has been selected since the  
ECP 1000 was first installed or since a system reset was  
performed, the number of screen selection buttons that  
light will be based on the type of wipe that was selected.  
For example, if you press a two-screen effect button, screen  
selection buttons 1 and 2 light.  
If this is not the first time any effect has been selected since  
the ECP 1000 was first installed or since a system reset was  
performed, the screen selection buttons that were selected  
the last time an effect was applied will light.  
If you want to deselect a screen that is lit and select a  
screen that is not lit, press the button for the screen that  
you want to turn off. For example, if buttons 1 and 2 are  
lit, and you want to apply the effect to screens 1 and 3  
instead, press the 2 button. The 2 button light turns off,  
and the 3 button light turns on.  
3.  
If you want to use a duration other than the default  
duration, turn the Adjust knob until the desired duration  
appears on the LCD menu’s default screen.  
4.  
5.  
If desired, press the Soft Edge button.  
Do one of the following.  
Press the Take button. The wiping switch begins  
immediately and is finished in the time specified by  
the duration. During the wipe, the LCD displays a  
percentage count (1 – 100) as the effect is completed  
(figure 3-12). The former preview image is now the  
new program image.  
28%  
3.0 SEC  
Figure 3-12 — Wipe percentage count  
ECP 1000 • Operation  
3-10  
ECP 1000 • Operation  
3-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation, cont’d  
ECP 1000 Event Control Panel  
Chapter Four  
4
Control Software for Windows  
Installing the Software  
Starting the Software  
ECP 1000 • Operation  
3-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Control Software for Windows  
The SGS 408 Control Program (Extron part number 29-049-01) ,  
which is used to configure the ECP 1000, is compatible with  
Windows 95/98 and Windows NT. It allows you to do the  
following:  
• Assign an effect to a user-programmable effect button.  
• Overwrite the effect assigned to either a pre-programmed  
effect button or a user-programmable effect button.  
• Print new keycap labels for reprogrammed effect buttons.  
• Create a series of effects that are initiated sequentially at the  
touch of a single effect button.  
The SGS 408 Control Program is the only method you  
can use to program the ECP 1000. RS-232 commands  
are not available.  
Figure 4-1 — SGS 408 Control Program window  
example (when an ECP 1000 is connected)  
For information about program features, you can access the  
help program in any of the following ways:  
Installing the Software  
The program is contained on a set of 3.5-inch diskettes. To  
install the program from the floppy disks to the hard drive, run  
SETUP.EXE from the floppy disk and follow the instructions  
that appear on the screen. The program occupies approximately  
3 MB (megabytes) of hard-drive space.  
• From the Extron Electronics program folder or group, double-  
click on the SGS 408 Help icon (shown at the left).  
SGS 408  
Help  
By default, the Windows installation creates a C:\SGS408  
directory, and it will place two icons (SGS 408 Control Pgm and  
SGS 408 Help) into a group or folder named “Extron  
Electronics”.  
• From within the SGS 408 Control Program, click on the Help  
menu on the main screen.  
• From within the SGS 408 Control Program, press the F1 key.  
Starting the Software  
After you have made changes to the user-programmable or  
pre-programmed effect buttons, you can print a page of new  
labels for the effect buttons. From the File menu, choose Print  
ECP keycap labels. The labels are printed to the default printer.  
Before starting the SGS 408 Control Program, you must  
put the ECP 1000 into program mode. Follow the  
instructions on page 3-5.  
See “Replacing keycap labels” on page A-5 for information on  
inserting the new labels into the keycaps.  
1.  
2.  
To run the SGS 408 Control Program, double-click on the  
SGS 408 Control Pgm icon (left) in the Extron  
Electronics group or folder.  
Click on the comm port that is connected to the RS-232  
port of the ECP 1000.  
The SGS 408 Control Program window appears (see  
figure 4-1 example). It displays the current settings of the  
ECP 1000.  
ECP 1000 • Control Software for Windows  
4-2  
ECP 1000 • Control Software for Windows  
4-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Control Software for Windows, cont’d  
ECP 1000 Event Control Panel  
Appendix  
A
Reference Information  
Maintenance and Upgrades  
Specifications  
Part Numbers  
ECP 1000 • Control Software for Windows  
4-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Information  
7.  
Attach the power cable to the ECP 1000 and to the power  
source. Make sure the ECP 1000 is working correctly.  
Maintenance and Upgrades  
You can perform the following maintenance operations and  
upgrades to the ECP 1000:  
Installing a firmware update  
• Cleaning the fan filter  
To install a firmware update, you may need to replace IC  
(integrated circuit) U9 or U11, or both. Replacing these  
ICs may result in loss of presets and other settings.  
• Installing a firmware update  
You can also replace the existing button labels if you have  
reprogrammed any of the effect buttons.  
1.  
2.  
Remove the power cable from the ECP 1000 and from the  
power source.  
Cleaning the fan filter  
Do not open the cover of the ECP 1000 without unplugging  
the power cord.  
The fan filter should be cleaned periodically, The frequency  
with which you need to clean the filter depends on the  
operating environment.  
Remove 10 screws from the back, top, and front of the  
cover (figure A-2).  
To clean the fan filter, do the following:  
Lift Cover straight up.  
1.  
Remove the power cable from the ECP 1000 and from the  
power source.  
Remove 10  
screws  
Do not open the fan cover without first unplugging the power  
cord.  
0
0
2.  
Using a small flat-blade screwdriver, pry the fan cover off  
of the rear panel of the ECP 1000 (figure A-1).  
0
L
E
1
N
A
P
C
P
L
E
O
R
T
N
O
S
JU  
C
T
D
N
A
E
V
E
Fan  
TO SGS  
3
2
1
PROGRAM  
100-240V  
50/60 Hz 0.5A  
Filter  
Figure A-2 — Removing the cover  
Pry off Cover  
Filter Cover  
3.  
Lift the cover from the ECP 1000 unit, and place it next to  
the unit.  
Make sure you are electrically grounded before  
touching IC chips. Electrostatic discharge (EDS)  
can damage IC chips, even if you cannot sense the  
discharge.  
Figure A-1 — Removing the fan filter  
3.  
4.  
5.  
6.  
Lift the filter out of the fan filter enclosure.  
Rinse the filter with water, and allow it to dry.  
Replace the filter in the fan filter enclosure.  
4.  
Remove the 12 screws that attach the control board to the  
bottom of the ECP 1000 (figure A-3).  
Press the fan filter cover back onto the rear panel of the  
ECP 1000. Make sure the left and right edges snap behind  
the shallow tabs on the sides of the fan filter enclosure.  
ECP 1000 • Reference Information  
A-2  
ECP 1000 • Reference Information  
A-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Information, cont’d  
5.  
Locate the ICs to be replaced (figure A-3). The update kit  
will list the specific ICs.  
socket, and gently press the IC into the socket.  
Reinstall the cover of the ECP 1000.  
8.  
9.  
Attach the power cord to the ECP 1000 and to the AC  
power source. Make sure the ECP 1000 is working  
correctly.  
Replacing keycap labels  
You can remove each effect button to reveal a legend plate  
(figure A-4). Remove the cap and insert a button label to  
identify the button’s new assignment. You can print labels from  
the SGS 408 Control Program (see page 4-3).  
Separate board and cover  
without straining the  
internal wire connectors.  
S
C
R
E
E
N
A
D
J
U
S
T
Screwdriver  
E
V
E
N
T
C
O
N
E
0
T
R
O
L
P
A
N
E
L
Remove 11  
screws  
U11  
TEXT  
U9  
Align Notches  
Figure A-3 — Locating and replacing ICs  
Figure A-4 — Removing a keycap  
6.  
Remove the existing chip and set it aside.  
To remove IC U9, use the PLCC (plastic leadless chip  
carrier) IC puller to remove the old IC. Align the hooks  
on the puller with the slots provided in opposite corners of  
chip socket U9. Insert the hooks, squeeze gently, and pull  
the IC straight out of the socket.  
Specifications  
General  
Power ............................................ 100VAC to 240VAC, 50/60 Hz, 60 watts,  
internal, auto-switchable  
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) /  
10% to 90%, non-condensing  
To remove IC U11, use a standard IC removal tool.  
Install the new chip.  
7.  
To install IC U9, locate the angled corner of the new chip.  
Orient the corner to match the angled corner of the socket,  
and press the IC into place.  
Operating +32° to +122°F (0° to +50°C) /  
10% to 90%, non-condensing  
Rack mount .................................. No  
Enclosure type .............................. Metal  
To install IC U11, locate a notch or a printed dot on top of  
the IC. Align the notch or dot with the notch on the socket  
or circuit board. Align the IC pins with the holes in the  
ECP 1000 • Reference Information  
A-4  
ECP 1000 • Reference Information  
A-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Reference Information, cont’d  
Enclosure dimensions ................. 4.6" H x 13.1" W x 7.0" D  
11.7 cm H x 33.3 cm W x 17.8 cm D  
(T-bar control adds up to 1.8” ((4.6 cm)) to  
height.)  
Product weight ............................. 4.4 lbs (2.0 kg)  
Shipping weight ........................... 10 lbs (4.5 kg)  
Vibration ....................................... ISTA/NSTA 1A in carton (International  
Safe Transit Association)  
Listings .......................................... UL, CUL  
Compliances ................................. CE, FCC Class A  
MTBF ............................................. 30,000 hours  
Warranty ....................................... 3 years parts and labor  
Specificationsaresubjecttochangewithoutnotice.  
(7.31-110701-D1)  
Part Numbers  
Extron Part  
Part Number  
60-344-01  
60-341-01  
60-343-01  
26-434-06  
26-434-08  
26-519-01  
26-519-02  
26-519-03  
26-519-04  
29-049-01  
68-518-01  
68-520-01  
68-519-01  
ECP 1000  
SGS 408  
RCP 1000  
ECP comm cable – 25’ (7.6 m)  
ECP comm cable – 50’ (15.2 m)  
RCP comm cable – 25’ (7.6 m)  
RCP comm cable – 50’ (15.2 m)  
RCP comm cable – 100’ (30.5 m)  
RCP comm cable – 300’ (91.4 m)  
SGS 408 Control Program  
ECP 1000 User’s Manual  
SGS 408 User’s Manual  
RCP 1000 User’s Manual  
ECP 1000 • Reference Information  
A-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Precautions  
Safety Instructions • English  
Warning  
FCC Class A Notice  
Power sources • This equipment should be operated only from the power source  
indicated on the product. This equipment is intended to be used with a main  
power system with a grounded (neutral) conductor. The third (grounding) pin is  
a safety feature, do not attempt to bypass or disable it.  
Thissymbolisintendedtoalerttheuserofimportant  
operating and maintenance (servicing) instructions  
in the literature provided with the equipment.  
Note: This equipment has been tested and found to comply with the limits for a  
Class A digital device, pursuant to part 15 of the FCC Rules. These limits are  
designed to provide reasonable protection against harmful interference when the  
equipment is operated in a commercial environment. This equipment generates,  
uses and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to  
cause harmful interference, in which case the user will be required to correct the  
interference at his own expense.  
Power disconnection • To remove power from the equipment safely, remove all  
power cords from the rear of the equipment, or the desktop power module (if  
detachable), or from the power source receptacle (wall plug).  
Power cord protection • Power cords should be routed so that they are not likely to  
be stepped on or pinched by items placed upon or against them.  
This symbol is intended to alert the user of the  
presence of uninsulated dangerous voltage within  
the product's enclosure that may present a risk of  
electric shock.  
Servicing • Refer all servicing to qualified service personnel. There are no user-  
serviceable parts inside. To prevent the risk of shock, do not attempt to service  
this equipment yourself because opening or removing covers may expose you to  
dangerous voltage or other hazards.  
Caution  
Read Instructions • Read and understand all safety and operating  
Slots and openings • If the equipment has slots or holes in the enclosure, these are  
provided to prevent overheating of sensitive components inside. These openings  
must never be blocked by other objects.  
instructions before using the equipment.  
Retain Instructions • The safety instructions should be kept for future  
reference.  
Follow Warnings • Follow all warnings and instructions marked on the  
equipment or in the user information.  
Lithium battery • There is a danger of explosion if battery is incorrectly replaced.  
Replace it only with the same or equivalent type recommended by the  
manufacturer. Dispose of used batteries according to the manufacturer's  
instructions.  
Avoid Attachments • Do not use tools or attachments that are not  
recommended by the equipment manufacturer because they may be  
hazardous.  
Note: This unit was tested with shielded cables on the peripheral devices.  
Shielded cables must be used with the unit to ensure compliance.  
Consignes de Sécurité • Français  
Avertissement  
Alimentations• Ne faire fonctionner ce matériel qu’avec la source d’alimentation  
indiquée sur l’appareil. Ce matériel doit être utilisé avec une alimentation  
principale comportant un fil de terre (neutre). Le troisième contact (de mise à la  
terre) constitue un dispositif de sécurité : n’essayez pas de la contourner ni de la  
désactiver.  
Ce symbole sert  
à
avertir l’utilisateur que la  
Extron’s Warranty  
documentation fournie avec le matériel contient des  
instructions importantes concernant l’exploitation  
et la maintenance (réparation).  
Extron Electronics warrants this product against defects in materials and  
workmanship for a period of three years from the date of purchase. In the event of  
malfunction during the warranty period attributable directly to faulty  
workmanship and/or materials, Extron Electronics will, at its option, repair or  
replace said products or components, to whatever extent it shall deem necessary to  
restore said product to proper operating condition, provided that it is returned  
within the warranty period, with proof of purchase and description of malfunction  
to:  
Déconnexion de l’alimentation• Pour mettre le matériel hors tension sans danger,  
déconnectez tous les cordons d’alimentation de l’arrière de l’appareil ou du  
module d’alimentation de bureau (s’il est amovible) ou encore de la prise secteur.  
Ce symbole sert à avertir l’utilisateur de la présence  
dansleboîtierdel’appareilde tensionsdangereuses  
non isolées posant des risques d’électrocution.  
Protection du cordon d’alimentation • Acheminer les cordons d’alimentation de  
manière à ce que personne ne risque de marcher dessus et à ce qu’ils ne soient  
pas écrasés ou pincés par des objets.  
Réparation-maintenance • Faire exécuter toutes les interventions de réparation-  
maintenance par un technicien qualifié. Aucun des éléments internes ne peut être  
réparé par l’utilisateur. Afin d’éviter tout danger d’électrocution, l’utilisateur ne  
doit pas essayer de procéder lui-même à ces opérations car l’ouverture ou le  
retrait des couvercles risquent de l’exposer à de hautes tensions et autres dangers.  
Attention  
Lire les instructions• Prendre connaissance de toutes les consignes de  
sécurité et d’exploitation avant d’utiliser le matériel.  
Conserver les instructions• Ranger les consignes de sécurité afin de  
pouvoir les consulter à l’avenir.  
Fentes et orifices • Si le boîtier de l’appareil comporte des fentes ou des orifices,  
ceux-ci servent à empêcher les composants internes sensibles de surchauffer. Ces  
ouvertures ne doivent jamais être bloquées par des objets.  
Respecter les avertissements • Observer tous les avertissements et  
consignes marqués sur le matériel ou présentés dans la documentation  
utilisateur.  
Lithium Batterie • Il a danger d'explosion s'll y a remplacment incorrect de la  
batterie. Remplacer uniquement avec une batterie du meme type ou d'un ype  
equivalent recommande par le constructeur. Mettre au reut les batteries usagees  
conformement aux instructions du fabricant.  
USA, Canada, South America,  
and Central America:  
Europe, Africa, and the Middle East:  
Eviter les pièces de fixation • Ne pas utiliser de pièces de fixation ni  
d’outils non recommandés par le fabricant du matériel car cela  
risquerait de poser certains dangers.  
Extron Electronics, Europe  
Beeldschermweg 6C  
3821 AH Amersfoort  
The Netherlands  
Sicherheitsanleitungen • Deutsch  
Vorsicht  
Extron Electronics  
1230 South Lewis Street  
Anaheim, CA 92805, USA  
Stromquellen • Dieses Gerät sollte nur über die auf dem Produkt angegebene  
Stromquelle betrieben werden. Dieses Gerät wurde für eine Verwendung mit  
einer Hauptstromleitung mit einem geerdeten (neutralen) Leiter konzipiert. Der  
dritte Kontakt ist für einen Erdanschluß, und stellt eine Sicherheitsfunktion dar.  
Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.  
Dieses Symbol soll dem Benutzer in der im  
Lieferumfang enthaltenen Dokumentation  
besonders wichtige Hinweise zur Bedienung und  
Wartung (Instandhaltung) geben.  
Stromunterbrechung • Um das Gerät auf sichere Weise vom Netz zu trennen,  
sollten Sie alle Netzkabel aus der Rückseite des Gerätes, aus der externen  
Stomversorgung (falls dies möglich ist) oder aus der Wandsteckdose ziehen.  
Schutz des Netzkabels • Netzkabel sollten stets so verlegt werden, daß sie nicht  
im Weg liegen und niemand darauf treten kann oder Objekte darauf- oder  
unmittelbar dagegengestellt werden können.  
Asia:  
Japan:  
DiesesSymbolsolldenBenutzerdaraufaufmerksam  
machen, daß im Inneren des Gehäuses dieses  
ProduktesgefährlicheSpannungen,dienichtisoliert  
sind und die einen elektrischen Schock verursachen  
können, herrschen.  
Extron Electronics, Japan  
Daisan DMJ Bldg. 6F,  
3-9-1 Kudan Minami  
Chiyoda-ku, Tokyo 102-0074  
Japan  
Extron Electronics, Asia  
135 Joo Seng Road, #04-01  
PM Industrial Bldg.  
Wartung • Alle Wartungsmaßnahmen sollten nur von qualifiziertem  
Servicepersonal durchgeführt werden. Die internen Komponenten des Gerätes  
sind wartungsfrei. Zur Vermeidung eines elektrischen Schocks versuchen Sie in  
keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen der Abdeckungen die  
Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.  
Schlitze und Öffnungen • Wenn das Gerät Schlitze oder Löcher im Gehäuse  
aufweist, dienen diese zur Vermeidung einer Überhitzung der empfindlichen  
Teile im Inneren. Diese Öffnungen dürfen niemals von anderen Objekten  
blockiert werden.  
Litium-Batterie • Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird.  
Ersetzen Sie verbrauchte Batterien nur durch den gleichen oder einen  
vergleichbaren Batterietyp, der auch vom Hersteller empfohlen wird. Entsorgen  
Sie verbrauchte Batterien bitte gemäß den Herstelleranweisungen.  
Achtung  
Lesen der Anleitungen • Bevor Sie das Gerät zum ersten Mal verwenden,  
sollten Sie alle Sicherheits-und Bedienungsanleitungen genau  
durchlesen und verstehen.  
Singapore 368363  
Aufbewahren der Anleitungen • Die Hinweise zur elektrischen Sicherheit  
des Produktes sollten Sie aufbewahren, damit Sie im Bedarfsfall darauf  
zurückgreifen können.  
This Limited Warranty does not apply if the fault has been caused by misuse,  
improper handling care, electrical or mechanical abuse, abnormal operating  
conditions or non-Extron authorized modification to the product.  
Befolgen der Warnhinweise • Befolgen Sie alle Warnhinweise und  
Anleitungen auf dem Gerät oder in der Benutzerdokumentation.  
Keine Zusatzgeräte • Verwenden Sie keine Werkzeuge oder Zusatzgeräte,  
die nicht ausdrücklich vom Hersteller empfohlen wurden, da diese eine  
Gefahrenquelle darstellen können.  
If it has been determined that the product is defective, please call Extron and ask for  
an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), or  
65.6383.4400 (Asia) to receive an RA# (Return Authorization number). This will  
begin the repair process as quickly as possible.  
Instrucciones de seguridad • Español  
Advertencia  
Este símbolo se utiliza para advertir al usuario sobre  
Alimentación eléctrica • Este equipo debe conectarse únicamente a la fuente/tipo  
de alimentación eléctrica indicada en el mismo. La alimentación eléctrica de este  
equipo debe provenir de un sistema de distribución general con conductor  
neutro a tierra. La tercera pata (puesta a tierra) es una medida de seguridad, no  
puentearia ni eliminaria.  
instrucciones importantes de operación  
y
mantenimiento (o cambio de partes) que se desean  
destacar en el contenido de la documentación  
suministrada con los equipos.  
Desconexión de alimentación eléctrica • Para desconectar con seguridad la  
acometida de alimentación eléctrica al equipo, desenchufar todos los cables de  
alimentación en el panel trasero del equipo, o desenchufar el módulo de  
alimentación (si fuera independiente), o desenchufar el cable del receptáculo de  
la pared.  
Units must be returned insured, with shipping charges prepaid. If not insured,  
you assume the risk of loss or damage during shipment. Returned units must  
include the serial number and a description of the problem, as well as the name of  
the person to contact in case there are any questions.  
Este símbolo se utiliza para advertir al usuario sobre  
la presencia de elementos con voltaje peligroso sin  
protección aislante, que puedan encontrarse dentro  
de la caja o alojamiento del producto, y que puedan  
representar riesgo de electrocución.  
Protección del cables de alimentación • Los cables de alimentación eléctrica se  
deben instalar en lugares donde no sean pisados ni apretados por objetos que se  
puedan apoyar sobre ellos.  
Reparaciones/mantenimiento • Solicitar siempre los servicios técnicos de personal  
calificado. En el interior no hay partes a las que el usuario deba acceder. Para  
evitar riesgo de electrocución, no intentar personalmente la reparación/  
mantenimiento de este equipo, ya que al abrir o extraer las tapas puede quedar  
expuesto a voltajes peligrosos u otros riesgos.  
Extron Electronics makes no further warranties either expressed or implied with  
respect to the product and its quality, performance, merchantability, or fitness for  
any particular use. In no event will Extron Electronics be liable for direct, indirect,  
or consequential damages resulting from any defect in this product even if Extron  
Electronics has been advised of such damage.  
Precaucion  
Leer las instrucciones • Leer y analizar todas las instrucciones de  
operación y seguridad, antes de usar el equipo.  
Conservar las instrucciones • Conservar las instrucciones de seguridad  
para futura consulta.  
Ranuras y aberturas • Si el equipo posee ranuras o orificios en su caja/alojamiento,  
es para evitar el sobrecalientamiento de componentes internos sensibles. Estas  
aberturas nunca se deben obstruir con otros objetos.  
Obedecer las advertencias • Todas las advertencias e instrucciones  
marcadas en el equipo o en la documentación del usuario, deben ser  
obedecidas.  
Batería de litio • Existe riesgo de explosión si esta batería se coloca en la posición  
incorrecta. Cambiar esta batería únicamente con el mismo tipo (o su equivalente)  
recomendado por el fabricante. Desachar las baterías usadas siguiendo las  
instrucciones del fabricante.  
Evitar el uso de accesorios • No usar herramientas o accesorios que no  
sean especificamente recomendados por el fabricante, ya que podrian  
implicar riesgos.  
Please note that laws vary from state to state and country to country, and that  
some provisions of this warranty may not apply to you.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Electro Voice Speaker S18 User Manual
Feiyue Vacuum Cleaner FM206 User Manual
Fisher Paykel Sleep Apnea Machine HC230 User Manual
Freestyle Watch Shark Classic User Manual
FUNAI DVD VCR Combo DVD3315V User Manual
Furuno Telephone FS 1503 User Manual
Gardena Trimmer THS 400 User Manual
Garmin GPS Receiver 100000000 User Manual
GE Cooktop JGP630 User Manual
GE Telephone 15381860 User Manual