FCC Class A Notice  
This equipment has been tested and found to comply with the limits for a Class A digital  
device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment.  
This equipment generates, uses, and can radiate radio frequency energy and, if not installed  
and used in accordance with the instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is likely to cause interference.  
This interference must be corrected at the expense of the user.  
ATTENTION: The Twisted Pair Extension technology works with unshielded twisted  
pair (UTP) or shielded twisted pair (STP) cables; but, to ensure FCC Class A and CE  
compliance, STP cables and STP Connectors are required.  
For more information on safety guidelines, regulatory compliances, EMI/EMF  
compatibility, accessibility, and related topics, see the “Extron Safety and  
Regulatory Compliance Guide” on the Extron website.  
Copyright  
© 2013 Extron Electronics. All rights reserved.  
Trademarks  
All trademarks mentioned in this guide are the properties of their respective owners.  
The following registered trademarks®, registered service marks(SM), and trademarks(TM) are the property of  
RGB Systems, Inc. or Extron Electronics:  
Registered Trademarks(®)  
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, GlobalViewer, Hideaway, Inline, IP Intercom,  
IP Link, Key Minder, LockIt, MediaLink, PoleVault, PowerCage, PURE3, Quantum, SoundField, SpeedMount, SpeedSwitch, System  
Integrator, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and XTP Systems  
Registered Service Mark(SM) : S3 Service Support Solutions  
Trademarks()  
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), AIS (Advanced Instruction Set), Auto-Image, CDRS (Class D  
Ripple Suppression), DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator,  
DSVP (Digital Sync Validation Processing), FastBite, FOXBOX, IP Intercom HelpDesk, MAAP, MicroDigital, ProDSP, QS-FPC (QuickSwitch  
Front Panel Controller), Scope-Trigger, SIS, Simple Instruction Set, Skew-Free, SpeedNav, Triple-Action Switching, XTRA, ZipCaddy,  
ZipClip  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Conventions Used in this Guide  
Notifications  
The following notifications are used in this guide:  
WARNING: A warning indicates a situation that has the potential to result in death or  
severe injury.  
ATTENTION: Attention indicates a situation that may damage or destroy the  
product or associated equipment.  
NOTE: A note draws attention to important information.  
Specifications Availability  
Product specifications are available on the Extron website, www.extron.com.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XTP PI 400 Power Injector • Contents  
vi  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
This guide contains information about the Extron XTP PI 400 Power Injector with instructions  
for experienced installers on how to install, configure, and operate the equipment.  
In this guide, the term “XTP PI 400” is used to refer to the XTP PI 400 Power Injector.  
This section provides basic information about this guide, the XTP PI 400, and key features  
of the XTP PI 400. Topics in this section include:  
About the XTP PI 400  
The Extron XTP PI 400 is a four port power injector that provides power for up to four  
remote XTP transmitters or receivers, eliminating the need for local power supplies.  
Designed specifically for the high data rates of XTP systems, signal quality is unaffected  
when using the power injector. It can be installed anywhere within the XTP signal path,  
providing design flexibility for remote devices with limited space. To ensure quick and  
dependable installation, the 1U, half rack width enclosure can be securely mounted using  
Extron rack shelves. The XTP PI 400 power injector provides integration flexibility in XTP  
systems with fully populated matrix switchers.  
XTP R HDMI  
Receiver  
XTP R HDMI  
Receiver  
OUTPUTS  
RELAYS  
POWER  
12V  
OVER XTP  
AUDIO  
AUDIO  
ON  
RS-232  
Tx Rx  
IR  
L
R
1
2
RESET  
OFF  
CT  
NK  
G
T
x
R
x
+
-
+
-
HDMI  
S/PDIF  
XTP T HDMI  
Transmitter  
SIG  
LINK  
INPUTS  
POWER  
12V  
AUDIO  
ON  
AUDIO  
OVER XTP  
L
R
RS-232  
IR  
--A MAX  
RESET  
PS 1210  
OFF  
ACTLANLINK  
HDMI  
LOOP-THRU  
+
+
T
x
R
x
T
x
R
x
G
XTP OUT  
Desktop Power  
Supply  
PS 1210  
Desktop Power  
Supply  
PS 1210  
Desktop Power  
Supply  
XTP Signal  
XTP Signal  
XTP Signal  
100-240V x.xA  
XTP PI 400  
4
1
2
3
PWR  
PWR  
PWR  
PWR  
XTP  
XTP PWR  
XTP  
XTP WR  
XTP  
XTP PWR  
XTP  
XTP PWR  
50/60 Hz  
XTP PI 400  
XTP Power Injector  
Remote Power  
SIG  
LINK  
POWER  
12V  
1.0A MAX.  
RESET  
RS-232  
XTP OUT  
Tx Rx  
SIG  
LINK  
INPUTS  
POWER  
12V  
--A MAX  
AUDIO  
ON  
AUDIO  
OVER XTP  
L
R
RS-232  
IR  
RESET  
XTP T UWP 202  
Transmitter  
OFF  
+
+
ACTLANLINK  
HDMI  
LOOP-THRU  
T
x
R
x
T
x
R
x
G
XTP OUT  
XTP T HDMI  
Transmitter  
OUTPUTS  
RELAYS  
AUDIO  
AUDIO  
ON  
L
R
1
2
RESET  
OFF  
T
x
R
x
+
-
+
-
HDMI  
S/PDIF  
IN  
XTP R HDMI  
Receiver  
Figure 1. Typical XTP PI 400 Point-to-point Application  
XTP PI 400 Power Injector • Introduction  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
IN  
IN  
IN  
IN  
IN  
IN  
IN  
IN  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
OUT  
REMOTE  
RS 232/RS422  
ACT  
LAN  
LINK  
RESET  
O
U
T
I
N
P
U
T
S
P
U
T
S
100-240V --A MAX  
50-60Hz  
DISCONNECT POWER  
CORD BEFORE  
SERVICING  
XTP Signal  
XTP Signal  
Extron  
XTP CrossPoint 3200  
100-240V x.xA  
XTP PI 400  
1
2
3
4
PWR  
PWR  
PWR  
PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
PWR  
50/60 Hz  
XTP PI 400  
XTP Power Injector  
Remote Power  
SIG  
LINK  
Remote Power  
POWER  
12V  
RESET  
1.0A MAX.  
RS-232  
Tx Rx  
XTP OUT  
SIG  
LINK  
XTP SR HDMI  
REMOTE  
OUTPUTS  
AUDIO  
L
POWER  
12V  
--A MAX  
OVER XTP  
RS-232  
S/PDIF  
HDMI AUDIO  
ON  
RELAYS  
IR  
R
1
2
RS-232  
RESET  
OFF  
XTP IN  
ACT  
LINK  
T
x
R
x
T
x
R
x
HDMI  
+
+
Remote Power  
Tx Rx  
LAN  
XTP T UWP 202  
Transmitter  
XTP SR HDMI  
XTP Scaling Receiver  
Remote Power  
SIG  
INK  
INPUTS  
XTP  
T
USW 103  
POWER  
12V  
--A MAX  
OVER XTP  
AUDIO  
RS-232  
IR  
CONTACT  
RS-232  
RESET  
1
2
3
XTP OUT  
ACT  
LINK  
T
x
R
x
T
x
R
x
1
2
3
T
x
R
x
LAN  
SIG  
LINK  
XTP SR HDMI  
REMOTE  
OUTPUTS  
AUDIO  
L
POWER  
12V  
--A MAX  
OVER XTP  
RS-232  
S/PDIF  
HDMI AUDIO  
ON  
RELAYS  
IR  
R
1
2
RS-232  
RESET  
OFF  
XTP IN  
CT  
LINK  
T
x
R
x
T
x
R
x
HDMI  
+
+
Tx Rx  
LAN  
XTP T USW 103  
XTP Transmitter  
XTP SR HDMI  
XTP Scaling Receiver  
Figure 2. Typical XTP PI 400 Matrix Application  
Features  
Supplies power for up to four remote XTP extenders — Provides power for up to  
four XTP transmitters or receivers over the XTP link, eliminating the need for local power  
supplies.  
Designed specifically for the high data rates of XTP systems  
No impact on signal quality — Utilization of the power injector does not affect video,  
audio, bidirectional RS-232 and IR, and Ethernet signal quality.  
Real-time status LEDs for troubleshooting and monitoring — Front and rear  
indicators provide status for each port that is supplying power to an XTP extender.  
UL/c-UL Listed and CE compliant  
1U, half rack width enclosure  
Internal universal power supply — The 100-240 VAC, 50-60 Hz, international power  
supply provides worldwide power compatibility.  
XTP PI 400 Power Injector • Introduction  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Installation and  
Operation  
This section contains installation procedures and operation features. Topics in this section  
include:  
Installation  
Important Safety Instructions  
This symbol, when used on the product, is intended to alert the user of important  
operating and maintenance (servicing) instructions in the literature provided with the  
equipment.  
This symbol, when used on the product, is intended to alert the user of the presence  
of uninsulated dangerous voltage within the product enclosure that may present a  
risk of electric shock.  
Read these instructions.  
Keep these instructions.  
Heed all warnings.  
Follow all instructions.  
Do not use this apparatus near water.  
Clean only with dry cloth.  
Do not block any ventilation openings. Install in accordance with the manufacturers  
instructions.  
Do not install near any heat sources such as radiators, heat registers, stoves, or other  
apparatus (including amplifiers) that produce heat.  
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug  
has two blades with one wider than the other. A grounding type plug has two blades and  
a third grounding prong. The wide blade or the third prong are provided for your safety. If  
the provided plug does not fit into your outlet, consult an electrician for replacement of the  
obsolete outlet.  
Protect the power cord from being walked on or pinched particularly at plugs, convenience  
receptacles, and the point where they exit from the apparatus.  
Only use attachments and accessories specified by the manufacturer.  
Unplug this device apparatus during lightning storms or when unused for long periods  
of time.  
XTP PI 400 Power Injector • Installation and Operation  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
WARNING: Risk of electrical shock. To reduce the risk of fire or electric shock, do  
not expose this apparatus to rain, moisture, dripping, splashing, or objects filled with  
liquids.  
Refer all servicing to qualified service personnel. Servicing is required when the apparatus  
has been damaged in any way, such as when the power supply cord or plug is damaged,  
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been  
exposed to rain or moisture, does not operate normally, or has been dropped.  
ATTENTION: This apparatus is a Class I product. This product must be connected to  
a mains socket outlet with a protective earthing connection.  
The mains plug is used as the disconnect device and must remain readily operable.  
WARNING: To prevent the risk of shock, do not attempt to service this equipment  
yourself because opening or removing covers may expose you to dangerous voltage  
or other hazards.  
ATTENTION:  
Power sources This equipment should be operated only from the power  
source indicated on the product. This equipment is intended to be used with a  
main power system with a grounded (neutral) conductor. The third (grounding) pin  
is a safety feature. Do not attempt to bypass or disable it.  
Power disconnection To remove power from the equipment safely, remove  
all power cords from the rear of the equipment, or the desktop power module (if  
detachable), or from the power source receptacle (wall plug).  
XTP PI 400 Power Injector • Installation and Operation  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rear Panel Connectors  
b c  
b c  
b c  
b c  
100-240V 1.6 A  
XTP PI 400  
1
2
3
4
PWR  
PWR  
PWR  
PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
50/60 Hz  
Figure 3. Rear Panel Features  
ATTENTION: Do not connect these devices to a computer data or telecommunications  
network.  
NOTE: The XTP PI 400 does not switch XTP signals.  
AC power connector — Connect the IEC power cord to the AC power connector.  
a
XTP connector — Connect an Extron XTP device that is powered by a local power  
source to the XTP connector on any of the four port pairs.  
b
XTP PWR connector — Connect an Extron XTP device that requires power from an  
external source to the XTP PWR connector. Make sure there is an XTP device plugged  
into the XTP connector on the same port pair.  
c
NOTE: Do not loop XTP port pairs on a single cable run to remotely power the  
transmitter and receiver. Figure 5, below, shows this type of application, which is not  
recommended by Extron.  
POWER  
12V  
--A MAX  
INPUTS  
SIG  
LINK  
AUDIO  
ON  
AUDIO  
OVER XTP  
INPUTS  
SIG  
LINK  
POWER  
12V  
--A MAX  
L
R
RS-232  
IR  
AUDIO  
ON  
AUDIO  
OVER XTP  
RESET  
L
R
RS-232  
IR  
RESET  
OFF  
+
+
LAN
HDMI  
LOOP-THRU  
T
x
R
x
G
T
x
R
x
XTOUT  
OFF  
ACTLANLINK  
HDMI  
LOOP-THRU  
+
+
T
x
R
x
G
T
x
R
x
XTUT  
XTP T HDMI  
Transmitter  
XTP T HDMI  
Transmitter  
CATx  
CATx  
Remote Power  
Remote Power  
100-240V x.xA  
XTP PI 400  
100-240V x.xA  
XTP PI 400  
1
2
3
4
1
2
3
4
PWR  
PWR  
PWR  
PWR  
PWR  
PWR  
PWR  
PWR  
XP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
50/60 Hz  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
XTP  
XTP PWR  
50/60 Hz  
CATx  
XTP PI 400  
XTP PI 400  
XTP Power Injector  
CATx  
XTP Power Injector  
CATx  
Remote Power  
SIG  
LINK  
OUTPUTS  
RELAYS  
POWER  
12V  
--A MAX  
OVER XTP  
AUDIO  
AUDIO  
ON  
RS-232  
IR  
L
R
1
2
RESET  
SIG  
LINK  
OUTPUTS  
RELAYS  
OFF  
POWER  
12V  
--A MAX  
OVER XTP  
ACTLANLINK  
T
x
R
x
G
T
x
R
x
+
-
+
-
AUDIO  
L
HDMI  
S/PDIF  
XTP IN  
AUDIO  
ON  
RS-232  
Tx Rx  
IR  
R
1
2
RESET  
OFF  
T
x
R
x
XTP IN  
ACTLANLINK  
HDMI  
S/PDIF  
G
+
-
+
-
XTP R HDMI  
Receiver  
XTP R HDMI  
Receiver  
CORRECT  
INCORRECT  
Figure 4. Correct application  
Figure 5. Incorrect application  
Installation Overview  
1. Mount the device in a rack, under a table, or on a tabletop (see Mounting on page 8).  
2. Connect a locally powered XTP device  
to the XTP connector on one of the port  
PWR  
pairs.  
XTP  
XTP PWR  
3. On the same port pair, connect an  
XTP device that requires power from  
an external source to the XTP PWR  
connector.  
To an XTP Device  
To an XTP Device  
that Requires an  
External Power Supply  
4. Repeat steps 2 and 3 for each XTP port  
pair as necessary.  
5. Connect AC power to the XTP PI 400.  
XTP PI 400 Power Injector • Installation and Operation  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Twisted Pair Cable Recommendations  
Use the following pin configurations for twisted pair cables.  
Pins:  
12345678  
TIA/EIA-T568B  
Pin Wire Color  
1
2
3
4
5
6
7
8
White-orange  
Orange  
White-green  
Blue  
White-blue  
Green  
Insert Twisted  
Pair Wires  
White-brown  
Brown  
RJ-45  
Connector  
Figure 6. Twisted Pair Cable Configuration  
Supported cables  
The XTP PI 400 is compatible with CAT 5e, 6, 6a, and 7 shielded twisted pair  
(F/UTP, SF/UTP, and S/FTP) and unshielded twisted pair (U/UTP) cable.  
ATTENTION:  
Do not use Extron UTP23SF-4 Enhanced Skew-Free AV UTP cable or STP201  
cable.  
To ensure FCC Class A and CE compliance, STP cables and STP connectors are  
required.  
Cable recommendations  
Extron recommends using the following practices to achieve full transmission distances up  
to 330 feet (100 m) and reduce transmission errors:  
Use the following Extron XTP DTP 24 SF/UTP cables and connectors for the best  
performance:  
XTP DTP 24/1000  
XTP DTP 24P/1000 Plenum 1000 feet (305 m) spool  
XTP DTP 24 Plug Package of 10  
Non-plenum 1000 feet (305 m) spool 22-236-03  
22-235-03  
101-005-02  
If you are not using XTP DTP 24 cable, at a minimum Extron recommends 24 AWG,  
solid conductor, STP cable with a minimum bandwidth of 400 MHz.  
Terminate cables with shielded connectors to the TIA/EIA-T568B standard.  
Limit the use of more than two pass-through points, which may include patch points,  
punch down connectors, couplers, and power injectors. If these pass-through points  
are required, use CAT 6 or 6a shielded couplers and punch down connectors.  
NOTE: Using more than three patches with the XTP PI 400 yields varying maximum  
cable lengths.  
Number of Patches  
Maximum Transmission Distance  
330 ft (100 m)  
1 or 2  
3
280 ft (85 m)  
NOTES: When using CAT 5e or CAT 6 cable in bundles or conduits:  
Do not exceed 40% fill capacity in conduits.  
Do not comb the cable for the first 20 m where cables are straightened, aligned,  
and secured in tight bundles.  
Loosely place cables and limit the use of tie wraps or hook-and-loop fasteners.  
Separate twisted pair cables from AC power cables.  
XTP PI 400 Power Injector • Installation and Operation  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
LED Indicators  
a
b
XTP POWER OUT  
1
2
3
4
XTP PI 400  
XTP POWER INJECTOR  
Figure 7. Front Panel Features  
Front panel power LED indicator — Lights to indicate the XTP PI 400 is receiving  
power.  
a
b
Front panel XTP Power Out LED indicators — Light when the XTP PI 400 is  
providing power to XTP devices connected to the XTP PWR connectors.  
NOTE: If the last connected XTP device that requires power draws more power  
than the XTP PI 400 can provide, the corresponding XTP Power Out LED  
indicator blinks, indicating the output cannot be powered due to the over power  
draw. Disconnect the XTP device to correct the issue.  
Rear panel Pwr LED indicators — Light or blink to indicate the various power states  
of the XTP device connected to the corresponding XTP PWR connector (see the table  
below for LED states).  
c
LED State  
Port Status  
c
Unlit  
The endpoint is not connected or cannot  
be powered.  
PWR  
Lit  
The endpoint is receiving power from the  
XTP PI 400.  
XTP  
XTP PWR  
XTP Port  
Blinks five times There is a power overload fault.  
Blinks nine times The power allocation is exceeded.  
XTP PI 400 Power Injector • Installation and Operation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Reference  
Information  
Mounting  
The XTP PI 400 is 1U high and one half rack wide.  
ATTENTION:  
The XTP PI 400 is not suitable for use in air handling spaces or in wall cavities. The  
power supply must be located within the vicinity of the Extron AV equipment in an  
ordinary location with pollution degree 2, and secured to an equipment rack within  
a dedicated closet, podium, or desk.  
The installation must be in accordance with the applicable provisions of National  
Electrical Code ANSI/NFPA 70, article 75 and Canadian Electrical Code part 1,  
section 16. The power supply must not be permanently fixed to building or similar  
structure.  
This device is for intra-building use only.  
1. Turn off or disconnect all equipment power sources.  
2. Mount the XTP PI 400 on a table, on a rack shelf, or under a desk using an optional  
mounting kit.  
WARNING: Risk of electrical shock. To reduce the risk of fire or electric shock, do  
not expose this apparatus to rain, moisture, dripping, splashing, or objects filled with  
liquids.  
Tabletop Mounting  
Attach the provided rubber feet to the bottom four corners of the enclosure.  
Under-the-table Mounting  
Use an optional Extron mounting kit to mount the XTP PI 400 under a desk or table. Follow  
the instructions included with the kit.  
XTP PI 400 Power Injector • Reference Information  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Rack Mounting  
Mount the XTP PI 400 to an optional Extron rack shelf. To mount the unit on a rack shelf,  
follow the instructions provided with the shelf accessories.  
1U Universal Rack Shelf  
1/2 Rack Width Front False  
Faceplate  
Front false  
faceplate uses  
2 screws.  
(2) 4-40 x 3/16"  
Screws  
NOTE: Using screws longer  
than 3/16" will damage the  
unit and void the warranty.  
Use 2 mounting holes on  
opposite corners.  
Figure 8. Half Rack Mounting  
UL Guidelines for Rack Mounted Devices  
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the  
XTP PI 400 in a rack.  
1. Elevated operating ambient temperature — If the equipment is installed in a closed  
or multi-unit rack assembly, the operating ambient temperature of the rack environment  
may be greater than room ambient temperature. Therefore, install the XTP PI 400 in an  
environment compatible with the maximum ambient temperature  
(Tma = +122 ˚F, +50 ˚C) specified by Extron.  
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow  
required for safe operation of the equipment is not compromised.  
3. Mechanical loading — Mount the equipment in the rack so that uneven mechanical  
loading does not cause a hazardous condition.  
4. Circuit overloading — Connect the equipment to the supply circuit and consider the  
effect that circuit overloading might have an overcurrent protection and supply wiring.  
Appropriate consideration of equipment nameplate ratings should be used when  
addressing this concern.  
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted  
equipment. Pay particular attention to supply connections other than direct connections  
to the branch circuit (for example, use of power strips).  
XTP PI 400 Power Injector • Reference Information  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Extron Warranty  
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years  
from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty  
workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components,  
to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is  
returned within the warranty period, with proof of purchase and description of malfunction to:  
USA, Canada, South America,  
and Central America:  
Extron Electronics  
1230 South Lewis Street  
Anaheim, CA 92805  
U.S.A.  
Japan:  
Extron Electronics, Japan  
Kyodo Building, 16 Ichibancho  
Chiyoda-ku, Tokyo 102-0082  
Japan  
Europe and Africa:  
Extron Europe  
Hanzeboulevard 10  
3825 PH Amersfoort  
The Netherlands  
China:  
Extron China  
686 Ronghua Road  
Songjiang District  
Shanghai 201611  
China  
Asia:  
Middle East:  
Extron Asia Pte Ltd  
135 Joo Seng Road, #04-01  
PM Industrial Bldg.  
Singapore 368363  
Singapore  
Extron Middle East  
Dubai Airport Free Zone  
F12, PO Box 293666  
United Arab Emirates, Dubai  
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical  
or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not  
authorized by Extron.  
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return  
Authorization) number. This will begin the repair process.  
USA: 714.491.1500 or 800.633.9876  
Asia: 65.6383.4400  
Europe: 31.33.453.4040  
Japan: 81.3.3511.7655  
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage  
during shipment. Returned units must include the serial number and a description of the problem, as well as the  
name of the person to contact in case there are any questions.  
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality,  
performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct,  
indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been  
advised of such damage.  
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may  
not apply to you.  
Extron Headquarters  
Extron Europe  
Extron Asia  
Extron Japan  
Extron China  
Extron Middle East  
Extron Korea  
Extron India  
+1.800.633.9876 (Inside USA/Canada Only)  
+800.3987.6673  
(Inside Europe Only)  
+65.6383.4400  
+65.6383.4664 FAX  
+81.3.3511.7655  
+81.3.3511.7656 FAX  
+86.21.3760.1568  
+86.21.3760.1566 FAX  
+971.4.299.1800  
+971.4.299.1880 FAX  
+82.2.3444.1571  
+82.2.3444.1575 FAX  
1800.3070.3777  
(Inside India Only)  
Extron USA - West  
+1.714.491.1500  
Extron USA - East  
+1.919.850.1000  
+31.33.453.4040  
+91.80.3055.3777  
+1.714.491.1517 FAX  
+1.919.850.1001 FAX  
+31.33.453.4050 FAX  
+91.80.3055.3737 FAX  
© 2013 Extron Electronics All rights reserved. www.extron.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Eagle Electronics Stereo System 320C User Manual
Fedders Heat Pump CH12 User Manual
Final Sound Speaker System F1000i User Manual
Fisher Paykel Cooktop OR305SDPWSX User Manual
Frigidaire Dishwasher 1400 User Manual
Fujitsu Speaker System TD508II User Manual
Garland Range G20 SP User Manual
GE Bread Maker 106732 User Manual
Goodman Mfg Gas Heater GDS8 User Manual
Go Video DVD Player DVD 22 User Manual