Dimplex Electric Heater APL150 User Manual

Installation and Operating Instructions  
Apollo Electronic Radiant Panel Heater  
Models:  
APL100 / APL150  
IP24  
Issue 1 January 2005  
Dimensions and Specification  
Model  
Loading  
(kW)  
1.0  
Height  
(mm)  
830  
Width Depth  
X
Y
Z
Weight  
(kg)  
(mm)  
440  
(mm)  
90  
(mm) (mm) (mm)  
248  
248  
APL100  
APL150  
96  
96  
96  
96  
1.5  
1040  
440  
90  
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE  
General  
IMPORTANT SAFETY ADVICE  
The compact Apollo range of radiant panel heaters are designed to  
provide comfortable radiant heat, with the added benefit of two rails for  
drying towels, in both domestic and commercial applications.  
When using electrical appliances, basic precautions should always be  
followed to reduce the risk of fire, electrical shock, and injury to  
persons, including the following:  
Wall Mounting / Installation  
The heater should be positioned observing the minimum clearances  
stated around the heater.  
WARNING THE SURFACES OF THIS HEATER CAN BE HOT  
Momentary contact with any part of the heater should not cause injury.  
However, aged or infirm persons or young children should not be left  
unsupervised in the vicinity of the heater unless a suitable guard is  
fitted  
(see also ‘Electrical’ section)  
The wall bracket supplied with the heater must be used  
IMPORTANT – If this heater is installed in a room containing a bath or  
shower, it should be so installed that switches and other controls  
cannot be touched by a person using a bath or shower – to comply  
with this requirement see ‘Lock the Control Cover’ section on page 2.  
If you use this heater in conjunction with an external thermal control, a  
programme controller, a timer or any other device which switches the  
heat on automatically, observe all safety warnings AT ALL TIMES since  
a fire risk exists when the heater is accidentally covered or displaced  
The installation of this product should be carried out by an electrician  
or competent person and be in strict accordance with the current IEE  
Wiring Regulations and relevant Building Regulations  
This heater must not be mounted within 150mm of curtains and other  
combustible materials or 100mm from a shelf or overhang  
NEVER cover or obstruct the front panel in any way  
DO NOT cover the heater – Do not place material or garments on the  
heater or obstruct the air circulation around the heater  
1. Remove wall mounting bracket from back of heater by de pressing  
the two spring latches at the top of the heater (see Fig.1)  
2. Fix wall bracket securely to wall via the three or four holes in the  
bracket with the appropriate fixings for the wall type (see Fig.2)  
3. Present heater to wall bracket and engage the two lower slots first.  
Then line up and push in the top two slots until the spring latches  
click in to place  
Before connecting the heater check that the supply voltage is the same  
as that stated on the heater  
The heater must be installed in accordance with these instructions  
The heater must be mounted using the wall bracket supplied. The  
heater should only be operated in the upright position  
Fig.1  
The heater should be positioned in accordance to the clearances  
stated in these instructions  
DO NOT locate this heater immediately beneath a fixed socket outlet  
Electrical  
The wires in the mains lead are coloured in accordance with the following code:  
GREEN & YELLOW EARTH  
BLUE  
BROWN  
BLACK  
NEUTRAL  
LIVE  
PILOT WIRE  
(See also ‘Pilot Wire Connection’)  
The heater is fitted with a length of flexible cable for connection to the fixed wiring of  
the premises through a suitable connection box positioned adjacent to the heater.  
The supply circuit to each heater must incorporate a double pole isolating switch having  
a contact separation of at least 3mm  
Fig.2  
Model  
APL100  
APL150  
A
B (Minimum)  
Pilot Wire Connection  
468  
618  
225  
285  
The BLACK control wire is designed to carry a signal from slot in or wall mounted Dimplex  
programmers. If, however a programmer is not being used, the pilot wire should be  
isolated in accordance with the current IEE Wiring Regulations.  
Do NOT connect the BLACK pilot wire to earth  
Any 240V insulated cable may be used to link pilot wires around the ring main. A low  
signal current is used. Suitable connections would be either an additional single core wire  
marked or colour coded appropriately or use a 4 core cable throughout the ring main.  
Please refer to the relevant programmer installation and operating instructions for further  
details on pilot wire connection  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Craftsman Tiller 900 299011 User Manual
Crescent Cardboard Company Car Speaker 5328 User Manual
Crown Audio Stereo Amplifier i Series User Manual
Curtis DVD Player DVD1053 User Manual
Dell Server HX574 User Manual
Digicom Digital Camera ES3310 User Manual
Dixon Lawn Mower 1857 0599 User Manual
Eagle Electronics SONAR 240I S User Manual
GE Double Oven JBP79 User Manual
Gefen Tool Storage GTB DVIKVM ELR User Manual