MULTI-TASKER™
MANUAL PART NUMBER: 400-0082-005
MT104-100/103
6-IN, 1-OUT VIDEO SWITCHER
CARD FOR MULTI-TASKER™
USER’S GUIDE
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
·
This equipment has been tested and found to
comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
PRECAUTIONS / SAFETY WARNINGS
1
Please read this manual carefully before using your
MT104-100/103. Keep this manual handy for future
reference. These safety instructions are to ensure
the long life of your MT104-100/103 and to prevent
fire and shock hazard. Please read them carefully
and heed all warnings.
equipment is operated in
a
commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at their expense.
1.1 GENERAL
·
Qualified ALTINEX service personnel, or their
authorized representatives, must perform all
service.
1.2 INSTALLATION
·
To prevent fire or shock, do not expose this unit
to rain or moisture. Do not place the
MT104-100/103 in direct sunlight, near heaters
or heat radiating appliances, or near any liquid.
Exposure to direct sunlight, smoke, or steam
can harm internal components.
·
Any changes or modifications to the unit not
expressly approved by ALTINEX, Inc. could void
the user’s authority to operate the equipment.
·
·
·
·
Handle the MT104-100/103 carefully. Dropping
or jarring can damage the card.
Do not pull the cables that are attached to the
MT104-100/103.
Insert the card carefully into the slots of the
Multi-Tasker™ without bending any edges.
When removing a card, please make sure that
the card to which it is attached is also pulled out
simultaneously.
1.3 CLEANING
·
Clean only the connector area with a dry cloth.
Never use strong detergents or solvents, such
as alcohol or thinner. Do not use a wet cloth or
water to clean the card. Do not clean or touch
any component or PCB.
1.4 FCC / CE NOTICE
·
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
400-0082-005
2
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
ABOUT YOUR MT104-100/103
2
TECHNICAL SPECIFICATIONS
3
FEATURES/
DESCRIPTION
GENERAL
MT104-100/103
MT104-100 & MT104-103
6-in 1-out MT Switcher Cards
The MT104-100 and MT104-103 are 6-in 1-out
Video Switcher Cards. These MT Video SW cards
enable 6 composite video sources to be connected
and switched to a single display or recording
device. The MT104-100 can be used together with
one or two Video SW Expansion Cards for up to 22
inputs. See the MT104-101 product sheet for more
information.
Inputs
(6) BNC Female (Analog
Video or TTL Sync)
(2) 10-pin IDC Connectors
External Connectors
Internal Connectors
Outputs
(1) BNC Female (Analog
Video or TTL Sync)
Output Connector
Capability
Using 1 Card
Using 2 Cards
Composite Video
S-Video (Y/C)
Component Video, RGsB,
& RsGsBs
Multiple MT Video SW series cards can be installed
into
a
Multi-Tasker™ enclosure to provide
additional functionality. For example, two MT Video
SW cards can be used to handle the two
components of an S-Video signal (Chroma and
Luma). In order to create a component video
switcher, simply install three of the MT Video SW
cards, one each for the Y, Pr, and Pb (or Y, R-Y,
B-Y) signal components. Similarly, the MT Video
SW series cards can also be used to pass
computer video signals: 4 cards for RGBS and 5
for RGBHV.
Using 3 Cards
Using 4 Cards
Using 5 Cards
Approvals
Expandability
MT104-100
RGBS
RGBHV, VGA thru UXGA*
CE/FCC
Up to 2 expansion cards.
Not expandable
MT104-103
Table 1. MT104-100/103 General
MECHANICAL
Enclosure Slots Required
Weight
Shipping Weight
Connector Panel
T° Operating
T° Storage
Humidity
MTBF (calc.)
MT104-100/103
The MT Video SW cards utilize solid state
switching technology, and offer the ability to pass
VGA thru UXGA high-resolution video signals
without degradation. Inputs are selected via easy-
to-use ASCII commands from a control system or
computer connected to the RS-232 port of a
Multi-Tasker™ enclosure. Also available through
ASCII control is “on-off” output control.
One
0.43lb (0.19kg)
1 lb. (0.45kg)
Black
10°C to 40°C
0°C to 50°C
90% non-condensing
55,000 hrs
Table 2. MT104-100/103 Mechanical
Additionally, by special order you can have VIS
(Vertical Interval Switching) capability added. This
is a feature that eliminates the "glitch" normally
associated with composite video switching.
*
Adapter required. See Table 3, Optional Accessories.
400-0082-005
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
DESCRIPTION OF MT104-100
4
ELECTRICAL
MT104-100/103
Input Signals
Analog
Or Digital
+/-1.5V (1.5Vp-p)
+5V
Impedance
75 Ohms
Type
Return Loss
Maximum DC Offset
Output Signals
Gain
Differential
-38dB @ 50MHz
10mV
1.05 (+/-5%)
75 Ohms
Impedance
Propagation Delay (Sync)
Rise/Fall time (Sync)
Differential Phase Error
Power
4nS max.
6nS max.
01° @ 4.5 MHz
Power
from MT100-100
MT104-100
MT104-103
+6V
-6V
Power
Consumption
1.1 watts
100mA 80mA
125mA 90mA
1.3 watts
Optional Accessories
6ft., 15-pin HD Male to 5 BNC
Male
6ft., 15-pin HD Female to 5
BNC Male
MS8102CA
MS8112CA
Table 3. MT104-100/103 Electrical
400-0082-005
4
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
APPLICATION DIAGRAMS
5
DIAGRAM 1: RGBHV CONFIGURATION
Use the MT104-100/103 card for RGBHV switching. One card is needed for each channel, for a total of 5
Video SW Cards: one card for R, one card for G, one card for B, one card for H and one card for V.
Connect IN 1 of the R signal card to the R signal from a laptop, video camera, etc. IN 2 will be connected to
the R signal of a Macintosh, document camera, etc. Continue this sequence for each card and signal.
Connect the VID OUT of the R signal card to the R signal from the projector. The same applies to the
G, B, H & V signals. Note: to group multiple cards, see the MT100-100 user's guide for more information.
400-0082-005
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
DIAGRAM 2: C-VIDEO CONFIGURATION
400-0082-005
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
DIAGRAM 3: INTERNAL VIEW
6 IN 1 OUT BNC SW + SIGNAL DETECT + EXPANDABLE + OUTPUT DISABLE
6 IN 1 OUT BNC SW + OUTPUT DISABLE
400-0082-005
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
INSTALLING YOUR MT104-100
6
OPERATION
7.1 RS-232 CONTROL
7
Step 1. Slide the MT104-100/103 into an available
slot in the Multi-Tasker™ Enclosure in
order to connect to the bus. Make sure
that the MT104-100/103 card fits into
place. Secure the card to the
Multi-Tasker™ by tightening the retainer
screws located on the top and bottom of
the MT104-100/103 card.
When used in the Multi-Tasker™ Enclosure, the
MT104-100/103 has many advanced remote
control capabilities, which are accessible through
standard RS-232 communication. The actual
controlling can be accomplished through
computer control system or any other device
capable of sending RS-232 commands.
a
Step 2. The LED on the card panel will turn red
indicating that the card is in full operation.
An LED that is blinking red indicates that
the card is experiencing a problem. If the
LED is blinking, see Troubleshooting
Guide in section 8. On the MT104-100, a
green LED indicates that a signal is
present.
7.1.1 RS-232 INTERFACE
The
RS-232
commands,
for
the
MT104-100/103, are in a simple ASCII character
format.
1. Square brackets “[ ]” are part of the
command.
2. Use uppercase letters for all commands.
Step 3. Connect a coaxial cable from the video
source to the input connector of the
MT104-100/103. Connect the output
connectors of the MT104-100/103 to the
display devices through a coaxial cable.
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string.
Commands ending in "S" will be saved into
memory. Commands not ending in "S" will still
be executed but will not be restored when the
system is reset or powered OFF then ON.
Step 4. Starting from the left, identify the slot
number where the MT104-100/103 card is
plugged into the Enclosure and note that
it is for RS-232 control.
7.2 DESCRIPTION OF COMMANDS
Each command consists of three parts:
Function, Card ID, and Unit ID.
[ Function , Card ID , Unit ID ]
Example: [VERC3U2]
VER = Function
C3 = Card ID or Group ID
U2 = Unit ID
For Function, see a detailed explanation under
each command description.
400-0082-005
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
The Card ID is an assigned value. It is equal to
the enclosure slot number in which the card is
installed. The value can range from 1 to 4 up to
1 to 20 depending on the enclosure.
2. [C]
This command receives the status of the card.
Command Format: [CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Card ID 0 (C0) is used for the controller. See
the MT100-100 User’s Guide for details.
The Group ID is a number representing a group
of cards defined with the [WR] command. When
using the Group ID, all cards in the group will
perform the given instruction.
There is one MT104-100 card in slot #4.
Sending
the
command
[C4]
to
the
Multi-Tasker™ will yield the following feedback:
Changing the position of a card will significantly
affect the commands recorded on software
definitions or third party control systems.
ON 4 C04
ON 4
C04
= Output 4 is selected and enabled
= The card is in slot 4
The Unit ID has a value from 0 to 9. Unit ID 0
should be used for single unit operation. If the
Unit ID is set to zero, each command may be
used without Ui. Use the command [SETU0],
as explained in the MT100-100 User’s Guide.
If there is no card in slot #4, sending the [C4]
command will not return any feedback.
3. [CnS]
This command saves the current status of the
card. This configuration will be restored after
system is reset or powered off then on.
Example:
[VERC3]:
[VERC3Ui]: For Unit ID other than Zero
[VERC3]: Equivalent to [VERC3U0]
For Unit ID Zero
Cn = card number (n = #1 to max slots)
S = save configuration
1. [VER]
If Input 1 is enabled, the feedback after sending
the command [C4S], for slot 4, would be:
This command receives the software version
and card type for the MT104-100/103 card.
ON:1 C04 Saved
Command Format: [VERCnUi]
Cn = card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
4. [?]
This command will return general information
about the Multi-Tasker™ and cards installed in
the unit.
There is one MT104-100/103 card is in slot #2
of unit 3. Send the command [VERC2U3], and
the Multi-Tasker™ Enclosure will return:
Command Format: [?Ui]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
MT104-100 690-0158-004
MT104-100 = card type
690-0158-004 = software version
400-0082-005
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Example:
The selected input shows the number of the
selected input if the card output is on. If the
output is off, the line will not show any input
number and would be as follows:
A Multi-Tasker™ has a front panel with part
number
MT104-100. Send the command [?] and receive
MT101-101
and
contains
an
+INC04
the following feedback:
[+MT101-101U0+MT104-100C01]
6. [STA]
MT101-101U01 = Panel Number and Unit ID
MT104-100C01 = An MT104-100 is in slot 1
This command enables/disables automatic
feedback from the front panel. The command
affects any card with auto-feedback capability,
not just the MT104-100/103. The default at
power on or reset is STA0, OFF.
5. [?Cn]
This command will return general information
about the card and its status. It is a function of
both the card and the front panel and is only
available with Multi-Tasker™ Front Panel
systems that have the following firmware:
Command Format [STA1] = ON
Command Format [STA0] = OFF
Feedback Prefix Definitions:
+VR = Firmware Version
+IN = Input Selected
690-0122-015
690-0123-004
690-0124-018
= Version 015 or later.
= Version 004 or later.
= Version 018 or later.
Example:
NOTE: In MTSetup™, send the command
[VER] from the Terminal Window. The system
will respond with feedback similar to the
following:
Command = [ON1C4]
Feedback = [+IN1C04]
+IN = Input Select
1
= Selected Input
[690-0122-015 690-0123-004 690-0124-018]
C04 = Card slot number
7. [ON]
Check the last three digits against the numbers
above to determine if the option is available.
This command enables one input of a single
card or a group of cards. There are 8 inputs for
the MT104-100 and 6 inputs for the MT104-103.
On the MT104-100, Inputs 7 and 8 are internal
inputs.
Command Format: [?CnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
Example:
[ONmCnUi]: Single Card
The MT104-100 in slot #4 has Input 4 selected
and the output is ON. Send the command [?C4]
to receive the feedback status.
This command enables input “m” and disables
all other inputs.
m = Input Number (m = 1 to max inputs)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = 0 to 9)
Each status field begins with a '+' and ends with
the card slot number (ex: C04). The feedback
will be similar to the following:
[+MT104-100C04+VR690-0158-004C04+IN4C04]
MT104-100
VR690-0158-004
IN4
= Card Type
= Firmware version
= Input 4 Selected
400-0082-005
10
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Example:
FEEDBACK OPTION
All of the inputs on the MT104-100/103 card are
OFF. The card is in slot #5 of Unit 3:
If "F" is included, use the [ONmCnUiPF]
command or the [ONmCnUiFP] command.
1) [ON1C5U3]: Turns ON only input 1 of the
MT104-100/103 card.
[ON…..F]: Feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string.
2) [ON3C5U3]: Turns ON only input 3 (input 1
is now OFF).
[ONmGkUi]: Group of Cards
Example:
This command enables input "m" for each card
in group "k" of unit "i".
[ON1C2F]: if path is not set
[ON1C2PF]: if path is set
m = Input Number (m = 1 to max inputs)
Gk = Group Number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
8. [OFF]
This command disables the output of a single
card or a group of cards.
[OFFmCnUi]: Single Card
m = Input Number that is ON (optional)
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID number (i = 0 to 9)
Example:
[ON1G1U1]: Turns ON input 1 for each card in
Group 1 of Unit 1.
PATH OPTION
[ON…..P]: Sets Path
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
preloaded.
Card 5 has Input 1 ON.
commands can be used to turn OFF the output.
The following
1) [OFF1C5]:
2) [OFFC5]:
Turns OFF only input 1.
Turns OFF any input.
[OFFmGkUi]: Group of Cards
Command Format: [ONmCnUiP]
This command disables input "m" for each card
in group "k" of unit "i".
m = Input (m = 1 to max inputs)
Cn = Card ID (n = slot # from 1 to max slots)
m = Input Number that is ON (optional)
Gk = group number (k = # from 1-8)
Ui = unit number (i = # from 0-9)
Example:
P
= Path
Example:
There are two MT104-100/103 cards in slots 6
and 7. Use the following commands to enable
input 1 of card 6 and input 3 of card 7
simultaneously:
1) [OFF1G1]: Turns OFF input 1 for each card
in Group 1.
2) [OFFG1]: Turns OFF any input for each
card in Group 1.
[ON1C6P]
[ON3C7P]
[SW]
400-0082-005
11
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
10. […F] – Feedback
PATH OPTION
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string.
[OFF…..P]: Sets Path
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
11. […P] – Path
This command will set the path for the output,
but it is not active until the switch command,
[SW], is executed. Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded. See examples in ON and OFF
commands.
Command Format: [OFFmCnUiP]
m = Input Number that is ON (optional)
n
= card ID (n = slot # from 1 to max slots)
= path
12. [SW] – Switch
P
The switch command immediately connects
inputs and outputs previously set with the path
command. The command switches all paths set
on this card and all other cards in the enclosure
Example:
There are two MT104-100/103 cards in slots 6
and 7. Disable Input 1 of card 6 and Input 3 of
card 7 simultaneously using the following
commands.
Example:
[ON1C6P]
[ON3C7P]
[SW]
[OFF1C6P]
[OFF3C7P]
[SW]
13. [SIG] – MT104-100 Only
FEEDBACK OPTION
The Signal Present command tests for the
If "F" is included, use the [OFFmCnUiPF]
command or the [OFFmCnUiFP] command.
presence of a signal.
After sending the
command, the feedback will be either "1"
signifying a signal is present, or a "0" indicating
no signal was detected.
[OFF…..F]: Feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string.
Command Format: [SIGCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Example:
[OFF1C2F]: if path is not set
[OFF1C2PF]: if path is set
To check for the presence of an input signal on
card 4, send the command [SIGC4] and verify
feedback of "1" or "0".
9. […S] – Save
This command will save the configuration
command being sent in memory.
When
sending the command [ON1C4S], after reset or
power up, Output 1 on C4 will be enabled.
400-0082-005
12
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Otherwise, failures will be indicated.
14. [AUTO] – MT104-100 Only
Command Format: [TESTCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
This command is used to enable or disable the
auto-switching feature. In auto-switch mode, the
first input with a signal detected will be
connected to the output. Use this where only
one active source is expected at a time.
CAUTION: Auto-switch mode disables manual
control of input selection.
There is an MT104-100 in slot #4. In order to
test the internal memory, send the command
[TESTC4].
Command Format: [AUTO=xCnUi]
17. [FBD]
x
= Auto Mode (0 = Manual, 1 = Auto)
This command turns feedback delay on or off .
It is necessary when installing some newer
cards in older systems. If the system does not
receive all of the feedback from the card, the
card may be communicating too fast. This
command will slow down the card's
communication rate.
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
Send the command [AUTO=1C4] to place the
MT104-100 in slot #4 in auto-switch mode. A
status of the card, [C4], will produce feedback
similar to the following:
Command Format: [FBDmCnUi]
m = Delay (0= no delay, 1= delay 100mS)
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = from 0 to 9)
Example:
ON 2 AUTO C04
15. [CLR]
This command resets the card configuration to
the factory defaults. After the [CLR] command,
Input 1 will be selected and ON.
The command [HELPC4] is sent to the card in
slot #4. Some of the HELP file is displayed on
the screen, but most is missing. Send the
command [FBD1C4] to slow down the rate at
which the card sends feedback to the system.
Command Format: [CLRCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
Example:
CARD ID COMMANDS
Send the command [CLRC4] to reset the card in
slot #4 to its factory defaults. The feedback after
sending the status command, [C4], will be as
follows:
The default Card ID is the same as the card slot
number. The next several commands allow the
user to change the Card ID to a value other than
the slot number.
ON 1 C04
The ID commands work with all Multi-Tasker™
Front Panel systems. However, front panels that
have firmware releases prior to the following will
not be able to address Card ID's greater than
the number of slots in the system:
16. [TEST]
This command performs a test on the internal
memory. Upon completion, the system will
display the results. If there are no problems, the
system will display the following:
MEMORY IS GOOD
400-0082-005
13
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
690-0122-019 = Version 019 or later.
690-0123-005 = Version 005 or later.
690-0124-019 = Version 019 or later.
19. [SIDn]
This command sets all the cards installed in the
Multi-Tasker™ system to the same Card ID.
After sending this command, all cards will be
addressed with the same ID. Use caution when
sending this command to a system with multiple
board types.
NOTE: In MTSetup™, send the command
[VER] from the Terminal Window. The system
will respond with feedback similar to the
following:
Command Format: [SIDn]
[690-0122-015 690-0123-005 690-0124-019]
n
= Card ID (n = # from 1 to 99)
Check the last three digits against the numbers
above to determine if the Card ID commands
can address all 99 Card ID's.
Example:
Send the command [SID1] to the system. All the
cards in the system now have ID 1. Any
commands that are sent to Card ID 1 will be
received and executed by each card.
Some cards require more than one slot in the
Multi-Tasker™ system. As an example, some
matrix switcher cards require 4 slots. If there are
5 of these cards installed, they would be
numbered C4, C8, C12, C16 and C20.
Changing the Card ID allows the user to define
the cards as C1, C2, C3, C4 and C5.
20. [SIDnCi]
This command sets the Card ID of a single card
to a number from 1 to 99.
Command Format: [SIDnCi]
Another use for changing the Card ID is to be
able to use multiple systems without having to
set each unit to a different Unit ID. All systems
may be left as Unit ID 0 for ease of
programming. The cards in the first unit may be
numbered 1-10 and in the second unit 11-20.
n
= Card ID (n = # from 1 to 99)
Ci = Slot Number (i = # from 1 to max slots)
Example:
Send the command [SID50C10] to set the ID of
the card in slot #10 to an ID of 50.
18. [RSI]
21. [SID+]
This command resets the card ID's in the
system. After sending this command, each card
ID in the system will match the slot number of
the card. Use this command along with the SID
commands that follow. The [RSI] command
MUST be used prior to changing Card ID's once
they have already been set.
This command sets the Card ID of all the cards
in a system to their slot number plus the offset
value.
Command Format: [SID+n]
n = Offset amount (n = # from 0 to 99)
The maximum Card ID is 99, so subtract
the highest slot number from 99 to find
the maximum offset. For example, in an 8
slot enclosure, the maximum offset would
be 91. The slot number, 8, plus the offset,
91, equals 99.
Command Format: [RSI]
Example:
Send the command [RSI] to the system with
Unit ID 0. The card in slot 1 will have ID 1, the
card in slot 2 will have ID 2 and so on.
400-0082-005
14
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Example:
Example:
There are two, 20 slot enclosures to be
connected together during normal operation.
The first unit will use the Card ID defaults which
are equal to their slot numbers. The second unit
will have the same Unit ID, but will have the
card ID's offset by 20.
In order to display the RS-232 commands
available for the MT104-100/103 card in slot #2,
send the command [HELPC2]. The commands
along with a brief description will be displayed in
the Terminal Window.
24. [WR]
Connect the computer to the second unit only
and send the command [SID+20] to set the ID
of all the cards in the enclosure to their slot
number plus 20. Reconnect both units to the
computer.
This command groups multiple cards in the
enclosure allowing all the group members to be
controlled simultaneously with the same
command. Each unit may define a maximum of
eight groups.
The cards in the first unit will be referenced as
Card ID's 1-20 and the cards in the second unit
will be referenced by Card ID's 21-40.
In Multi-Tasker™ systems with audio and video
cards, boards are typically grouped as follows:
Group 1 = Video Cards
Group 2 = Audio Cards
22. [RSN]
This command reads the slot number of the
card with a specified ID number, and returns the
value to the system to be displayed in the
terminal window. If more than one card has the
same ID, each slot number will be displayed.
Group 3 = Video and Audio Cards
If assigning group commands to button
functions, it is best to use the "Press and Hold
on Power Up" to make group settings.
Command Format: [WRCn1Cn2…GkUi]
Cn = Card ID (n = slot # from 1 to max slots)
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Command Format: [RSNCi]
Ci = Card ID (i = # from 1 to 99)
Example:
The card in slot #4 takes up four slots in the
enclosure. Its ID was set to 1 since it is the first
card installed in the system, reading from left to
right. Send the command [RSNC1] to find the
slot number of this card. The system responds
with the following feedback:
Example:
To group cards 1, 2, and 3 as group 5 of
Unit ID 1,
[WRC1C2C3G5U1].
send
the
After
command
executing this
command, cards 1, 2 and 3 will be grouped
together as group 5 of Unit ID 1. The system will
return the following feedback:
4
G1=C1C2C3
23. [HELP]
Now, when a command is sent to G1, each
board in G1 will execute the same command.
This command displays information available for
the Multi-Tasker interface commands.
25. [RMC]
Command Format: [HELPCnUi]
Cn = Card ID (n = # from 1 to max slots)
Ui = Unit ID (i = # from 0 to 9)
This command may be used to remove one or
more group members from a group. Reset the
system after using this command for all changes
to take effect.
400-0082-005
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Command Format: [RMCn1Cn2…GkUi]
27. [RD]
Cn = Card ID (n= # from 1 to max slots)
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
This command reads and then displays the
members in each group.
Command Format: [RDGkUi]
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
Example:
Group 1 consists of the cards located in slots
numbered 1, 2, 3, 4 and 5. Remove just cards
#4 and #5 from the group by sending the
command [RMC4C5G1]. The system will return
the following feedback:
The cards in slots 1, 2 and 19 are part of
group 5. Read the member data for group 5, by
sending the command [RDG5]. The system will
return feedback as follows:
G1=C1C2C3
26. [RMG]
G1=C1C2C19
This command may be used to delete an entire
group, or all groups.
The feedback shows G1 (Group 1) and then the
cards that make up Group 1. In this case,
Group 1 includes C1, C2 and C19.
REMOVE ONE GROUP MEMBERS
Remove all the members from the group,
effectively deleting the group.
28. [CLM]
This command removes the members in a
group and leaves the group empty. It is
equivalent to sending the [RMGkUi] command
without card references.
Command Format: [RMGkUi]
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
Command Format: [CLMGkUi]
Gk = Group number (k = # from 1-8)
Ui = Unit ID (i = # from 0-9)
Example:
Group 1 consists of the cards located in slots
number 1, 2 and 3. Remove all cards from the
group by sending the command [RMG1]. The
system will return the following feedback:
Group 5 of Unit ID 1 contains the cards in slots
1, 2 and 19. Read the member data for group 5
of Unit ID 1. Send the command [RDG5U1] and
receive the following feedback:
G1=EMPTY
REMOVE ALL GROUPS
Remove all the members from every group,
effectively deleting all groups.
G1=C1C2C19
Command Format: [RMGÜ Ui]
Ui = Unit ID (i = # from 0-9)
Example:
Now, clear group 5 by sending the command
[CLMG5U1]. Reread the member data as above
and note the following feedback:
G1=EMPTY
Group 1 consists of cards 1 and 2. Group 2
consists of cards 1, 2, 3, 4 and 5. Delete all the
groups by sending the command [RMGÜ ]. The
system will return the following feedback:
G1-G8:EMPTY
400-0082-005
16
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
7.3 SUMMARY OF COMMANDS
Card Commands
7.4 MENU MODE
MENU MODE commands are RS-232 commands
that allow virtually the same functionality as
programming commands. Unlike the programming
commands in the previous sections, 7.2 and 7.3,
MENU commands prompt the user to select from a
list of available options. The system then responds
based upon selections made by the user.
1) [VER]
2) [C]
Receives software version
Receives status of the card
Save card settings
3) [CnS]
4) [?]
Show system cards
MENU commands may be issued in response to
prompts from within MTSetup™ or other RS-232
communication software.
5) [?C]
6) [STA]
7) [ON]
8) [OFF]
9) […S]
10) […F]
11) […P]
12) [SW]
13) [SIG]
Show card information
Enable/disable auto feedback
Turn output ON for card/group
Turn output OFF for card/group
Save card settings
The MENU driven commands are only available
with Multi-Tasker™ Front Panel systems that have
the following firmware:
690-0122-015 = Version 015 or later.
690-0123-004 = Version 004 or later.
690-0124-018 = Version 018 or later.
Display command feedback
Sets the path, preload for [SW]
Switch preloaded output buffer
Signal Detect
NOTE: In MTSetup™, send the command [VER]
from the Terminal Window. The system will
respond with feedback similar to the following:
14) [AUTO] Auto-Switching control
15) [CLR] Reset card to default values
16) [TEST] Test internal memory IC's
[690-0122-015 690-0123-004 690-0124-018]
Check the last three digits against those above to
determine if the MENU MODE option is available.
7.4.1 MENU COMMAND DEFINITIONS
17) [FBD]
18) [RSI]
19) [SIDn]
Feedback delay on/off
Reset Card ID’s
Refer to section 7.2 for details on functions and
examples. Following is a cross-reference of
menu mode versus programming functions.
Set all Card ID’s
20) [SIDnCi] Set one Card ID
21) [SID+n] Set Card ID offset
MENU
Control
Select
Save
COMMAND
n/a
22) [RSN]
Read Card slot number
[CnS], [..S]
Clear
Switch
Setup
Group
Status
[CLR], [CLRG]
[ON], [OFF]
23) [HELP] Display available commands
Group Commands
[WR], [CLM], [RMC], [RMG]
[VER], [C]
24) [WR]
Groups multiple cards
25) [RMC] Remove members from group
26) [RMG] Delete group
Help
[HELP]
[?], [?Cn], [...F], [...P],
[AUTO], [FBD], [RDG], [RSI],
[RSN], [SID], [SIDnCi],
[SID+n], [SIG], [STA], [SW],
[TEST]
Not Available
27) [RD]
Displays group members
28) [CLM] Delete group
400-0082-005
17
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
8. Read each menu carefully, and continue
selecting keys as prompted for further
functions. (Example prompt: "Key= ")
7.4.2 USING MENU MODE
SUGGESTION: Before using the menu mode, it
is best to disable the automatic feedback
feature. The values and current settings will be
displayed in the menu mode, but the automatic
feature will display after each setting change
making the menus difficult to read.
7.4.3 MENU TYPES
1. MAIN MENU
The first menu displayed after selecting the
card is the Main Menu. This menu provides
access to the main functions related to the
card. Press the key representing the menu
item for access. A sub menu will appear
next.
1. In order to enter MENU mode, the system
needs to be connected to a computer
running MTSetup™ or other RS-232 control
software.
2. Insert the card into an empty slot and push
in all the way for a secure fit.
2. SUB MENUS
Each sub menu will display either another
menu (sub menu) or a list of available
options or settings. Press the key
corresponding to the menu choice to
change a setting or select the next menu.
3. Reset the system or power the system OFF
and then ON.
4. In MTSetup™, click the cursor in the
Terminal Window and press the ENTER
key.
NOTE: Pressing the ESCAPE (ESC) key in
most menus will take you up to the previous
menu without making changes in the
current menu.
5. The system will interrogate the enclosure
and return a list of cards installed and their
slot locations.
Example: 08 (Slot 8): MT104-100
7.4.4 MT104-100 MENUS
NOTE: Only cards supporting the MENU
feature will be displayed.
Following are the menus available to the
MT104-100. The first menu is the Main Menu
only. The second listing is an expansion of all
the menu items available.
5. Find
the
alphanumeric
characters
representing the card whose setup requires
changing. It will be the first one or two
characters in the line.
The expanded menu contains values that
indicate the current setting or value of a
parameter. The value is usually in parentheses,
or otherwise indicated at the top of a sub menu.
In some areas, additional comments are
provided for clarification.
6. Press the number or letter associated with
the card, and a menu with options available
for that card will appear on the screen. In
the example above, press "08".
CAUTION: Pay special attention to the top of
the CONTROL menu. After selecting the
CONTROL menu, THIS CARD or a group will
be identified at the top of the sub menu. Since
group functions may be modified from this
menu, make sure the desired card or group is
selected.
WARNING: Do NOT enter any characters
except the one relating to the desired
menu. Pressing ENTER or RETURN after
"08" will force the system back to the
original prompt.
7. After selecting the MT104-100 as described
above, the system will prompt for selections
specific to that card.
400-0082-005
18
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
MT104-100/103 MAIN MENU
PRESS KEY TO SELECT
4: SWITCH (Switch I/O Connection)
SWITCH: (INPUT1)
1: INPUT1
1: CONTROL
2: SETUP
3: STATUS
4: HELP
2: INPUT2
3: INPUT3
4: INPUT4
5: INPUT5
ESC: GO BACK
6: INPUT6
7: INPUT7
8: INPUT8
ESC: GO BACK; S:STATUS
KEY =
MT104-100/103 EXPANDED MENUS
1. CONTROL
ESC: GO BACK
CONTROL: FOR THIS CARD
1: SELECT (Select Card/Group for Control)
CURRENT SELECTION: THIS CARD
2: SETUP
SETUP:
1: SET GROUP ID
0: This Card
1: Group 1
2: Group 2
3: Group 3
4: Group 4
5: Group 5
6: Group 6
7: Group 7
8: Group 8
SET GROUP ID: (NONE)
1: ASSIGN GROUP ID+
2: DELETE GROUP ID+
ESC: GO BACK
3: STATUS
Equivalent to the [C] command.
Returns the card status.
ESC: GO BACK
2: SAVE (Save Card Settings)
ON 1 C03
4: HELP
Equivalent to the [HELP] command.
Displays a list of commands available for the
MT104-100/103 along with a brief
description.
SAVE THIS SETTING?
1: YES
2: NO
ESC
3: CLEAR (Set to Defaults)
Returns to the parent menu.
RESET CARD TO FACTORY DEFAULT:
7.4.5 MENU MODE EXAMPLES
* Switch to Input 1
All MENU MODE examples assume an
MT104-100 is installed in slot #4. Start by
clicking the mouse in the Terminal window.
Press ENTER and a list of available cards will
be displayed.
1: YES
2: NO
NOTE When entering numeric values (not
selecting menu items) the system may
echo each character as it is typed.
400-0082-005
19
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
1. Select Input 2
TROUBLESHOOTING GUIDE
8
Follow the keystrokes below to select Input 2 as
the source input.
We have carefully tested and have found no
problems in the supplied MT104-100/103; however,
we would like to offer suggestions for the following:
Enter
04
1
4
2
List available cards
Select MT104-100 in slot #4
Select CONTROL Menu
Select SWITCH control
Select Input 2
8.1 LED IS NOT ON
Cause 1: Card cage is not plugged in.
Solution: Plug card cage in. If the LED lights,
the problem is solved. If the LED is
still not on, see Cause 2.
ESC
ESC
Return to CONTROL Menu
Return to the MAIN Menu
Cause 2: Card is not plugged in all the way.
2. Save the card setting
Solution: Push the card in all the way. If the
Starting from the main menu, save the card
settings. Follow the keystrokes below.
LED is still not lit, see Cause 3.
Cause 3: Card cage slot has a problem.
1
2
1
ESC
Select Control Menu
Select SAVE control
Answer YES to save
Return to the MAIN Menu
Solution 1: Test the card in other slots of the
card cage. If the slot was damaged,
the card may work in other slots. If
other slots work and the LED lights,
the problem is the card cage slot.
The card cage may require service.
Call ALTINEX at (714) 990-2300. If
the other slots do not work and the
LED is still not on, see Solution 2.
3. Assign to Group 2
Starting from the main menu, assign the
MT104-100 in slot #3 to Group 2. Follow the
keystrokes below.
2
1
1
2
Select SETUP Menu
Select SET GROUP ID
Assign GROUP ID
Solution 2: Take any other known good card
with an LED. Insert the good card
into the slot in question. If the LED
lights, then the original card may be
the source of the problem. Call
ALTINEX at (714) 990-2300.
Assign to Group 2
The contents of Group are displayed.
Return to SET GROUP ID menu
Return to CONTROL menu
Return to the MAIN Menu
ESC
ESC
ESC
8.2 LED IS BLINKING RED
Cause 1: The CPU on the card is not
working properly.
4. Display Card Status
Starting from the Main Menu, follow the
keystrokes below.
Solution 1: Look at the card and verify that
there is no damage. If there is no
damage, see Solution 2.
3
Displays card status
NOTE: The status will be displayed, followed
by the Main Menu being redisplayed.
Solution 2: Verify that all IC’s are seated in their
sockets. If the LED is still blinking
red, see Solution 3.
Solution 3: Call ALTINEX at (714) 990-2300.
400-0082-005
20
Download from Www.Somanuals.com. All Manuals Search And Download.
MULTI-TASKER™
Cause 2 The card and its serial device are
not communicating.
ALTINEX POLICY
9.1 LIMITED WARRANTY/RETURN POLICY
Please see the Altinex website
9
Solution 1: Turn the system OFF and then ON
again. If there is still an error, see
Solution 3.
at
www.altinex.com for details on warranty and
return policy.
Solution 2: Call ALTINEX at (714) 990-2300.
9.2 CONTACT INFORMATION
ALTINEX, INC
Cause 3: RS485 communication error
Solution 1: Make sure that the card is pushed
all the way into the slot. If there is
still an error, see Solution 2.
592 Apollo street
Brea, CA 92821 USA
TEL: 714 990-2300
Solution 2: Turn the system OFF and then ON
again. If there is still an error, see
Solution 3.
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: [email protected]
Solution 3: If there is still a problem, call
ALTINEX at (714) 990-2300.
8.3 NO DISPLAY
Cause 1: The source has a problem.
Solution: Check the source and make sure
that there is a signal present and all
source connections are correct. If
the source is working and there is
still no display, see Cause 2.
Cause 2 The card input is not selected.
Solution: Select the card input. See RS-232
accessible commands in section 7.
If there is still no display present,
see Cause 3.
Cause 3 Cable connections are incorrect.
Solution: Make sure that the cables are
connected properly. Also, make sure
that the continuity and wiring are
good. If there is still no display
present, see Cause 4.
Cause 4: The display has a problem.
Solution: Make sure that the display is
powered. If there is still no display,
call ALTINEX at (714) 990-2300.
400-0082-005
21
Download from Www.Somanuals.com. All Manuals Search And Download.
|