Eighteen Port Managed Industrial
Ethernet Switches
User Manual
Download from Www.Somanuals.com. All Manuals Search And Download.
Notice
The contents of this manual are based on the firmware, kernel
version, and hardware version listed below.
Firmware Version
Kernel Version
V1.07
V2.07
Hardware Version
----------
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
FCC Warning
This Equipment has been tested and found to comply with the limits for a
Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy. It may cause harmful interference to radio
communications if the equipment is not installed and used in accordance
with the instructions. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning
This is a Class-A product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Content
Introduction................................................................ 1
Features ................................................................... 1
Software Specification.............................................. 3
Package Contents.................................................... 5
Hardware Description................................................ 6
Physical Dimension.................................................. 6
Front Panel............................................................... 6
Top View .................................................................. 7
LED Indicators.......................................................... 8
Ports......................................................................... 9
Cabling ................................................................... 11
Wiring the Power Inputs......................................... 14
Wiring the Fault Alarm Contact .............................. 15
Mounting Installation............................................... 16
DIN-Rail Mounting.................................................. 16
Wall Mount Plate Mounting .................................... 18
Hardware Installation .............................................. 19
Network Application................................................ 20
Download from Www.Somanuals.com. All Manuals Search And Download.
X-Ring Application.................................................. 20
Coupling Ring Application...................................... 21
Dual Homing Application........................................ 22
Console Management.............................................. 23
Connecting to the Console Port ............................. 23
Pin Assignment ...................................................... 23
Login in the Console Interface ............................... 24
CLI Management.................................................... 25
Commands Level .............................................................26
Commands Set List..........................................................27
System Commands Set....................................................27
Port Commands Set.........................................................30
Trunk Commands Set ......................................................32
VLAN Commands Set ......................................................33
Spanning Tree Commands Set........................................35
QOS Commands Set........................................................38
IGMP Commands Set ......................................................38
Mac / Filter Table Commands Set....................................39
SNMP Commands Set .....................................................40
Port Mirroring Commands Set..........................................42
802.1x Commands Set.....................................................43
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP Commands Set.......................................................45
SystemLog, SMTP and Event Commands Set.................45
SNTP Commands Set......................................................47
X-ring Commands Set......................................................48
Web-Based Management ........................................ 50
About Web-based Management ............................ 50
Preparing for Web Management............................ 50
System Login.......................................................... 51
System Information ................................................ 52
IP Configuration ..................................................... 52
DHCP Server – System configuration.................... 54
DHCP Server – Client Entries................................ 54
DHCP Server - Port and IP Bindings ..................... 55
TFTP - Update Firmware ....................................... 56
TFTP – Restore Configuration ............................... 56
TFTP - Backup Configuration................................. 57
System Event Log – Syslog Configuration............. 57
System Event Log - SMTP Configuration .............. 58
System Event Log - Event Configuration ............... 59
Download from Www.Somanuals.com. All Manuals Search And Download.
Fault Relay Alarm................................................... 61
SNTP Configuration ............................................... 61
IP Security.............................................................. 64
User Authentication................................................ 65
Port Statistics ......................................................... 66
Port Control............................................................ 67
Port Trunk............................................................... 68
Aggregator setting............................................................68
Aggregator Information.....................................................70
State Activity.....................................................................70
Port Mirroring.......................................................... 72
Rate Limiting .......................................................... 73
VLAN configuration ................................................ 74
VLAN configuration - Port-based VLAN ...........................74
802.1Q VLAN ...................................................................77
Rapid Spanning Tree ............................................. 80
RSTP - System Configuration ..........................................80
RSTP - Port Configuration................................................81
SNMP Configuration .............................................. 83
System Configuration.......................................................83
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Trap Configuration............................................................84
SNMPV3 Configuration ....................................................85
QoS Configuration.................................................. 88
QoS Policy and Priority Type ...........................................88
Port-based Priority............................................................89
COS Configuration ...........................................................90
TOS Configuration............................................................90
IGMP Configuration................................................ 90
X-Ring .................................................................... 92
Security .................................................................. 94
802.1X/Radius Configuration ...........................................94
MAC Address Table .........................................................97
Factory Default....................................................... 99
Save Configuration............................................... 100
System Reboot..................................................... 100
Trouble shooting.................................................... 101
Technical Specification......................................... 102
Download from Www.Somanuals.com. All Manuals Search And Download.
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
This managed industrial switch comes equipped with a proprietary
redundant network protocol—X-Ring which provides an easy way to
establish a redundant Ethernet network. With ultra high-speed recovery time
(less than 300 ms) and a long MTBF (Mean Time Between Failures) the
industrial switch will continue to operate until a Gigabit network infrastructure
has been established, without requiring extra upgrade costs.
In addition to 10/100/1000Base-TX fast Ethernet ports, the switch has SFP
(mini-GBIC) ports. Traditional RJ-45 ports can be used for up linking short
distance (less than 100 m) wide-band paths, while the SFP slots can be
used for the application of wideband uploading and long distance
transmissions adding flexibility
Features
System Interface/Performance
¾
¾
¾
¾
¾
¾
¾
RJ-45 ports support Auto MDI/MDI-X Function
SFP (mini-GBIC) supports 100/1000 Dual Mode
Store-and-Forward Switching Architecture
Back-plane (Switching Fabric): 7.2Gbps
1Mbits Packet Buffer
8K MAC Address Table
Wide Operating Temperature (-40oC to 75oC)*
Case/Installation
¾
¾
IP-30
DIN-Rail and Panel Mount
Power Supply
¾
¾
¾
Wide Range Redundant Power Design
Reverse Polarity Protection
Current Overload Protection
Manual Documentation Number: EIR618-2SFP-T_5107m
1
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Spanning Tree
¾
¾
IEEE 802.1d Spanning Tree
IEEE 802.1w Rapid Spanning Tree
VLAN
¾
¾
¾
Port Based VLAN
802.1 Q Tag VLAN
GVRP
X-Ring
¾
X-Ring, Dual Homing, Couple Ring, and Central Ring Topology
Port Trunk with LACP
QoS (Quality of Service)
¾
¾
¾
IEEE 802.1p Class of Service
Four priority queues per port
Port Base, Tag Base and Type of Service Priority
Bandwidth Control
¾
¾
Ingress Packet Filter and Egress Rate Limit
Broadcast/Multicast Packet Filter Control
Port Mirror: Monitor traffic in switched networks
¾
¾
¾
TX Packet only
RX Packet only
Both of TX and RX Packet
System Event Log
¾
¾
¾
System Log Server/Client
SMTP e-mail Alert
Relay Alarm Output System Events
Security
¾
¾
¾
Port Security : MAC address entries/filter
IP Security: IP address security management to prevent intrusion
Login Security: IEEE802.1X/RADIUS
SNMP Trap
¾
¾
¾
¾
Cold Start, Power status
Authentication failure
X-Ring topology change
Link up / Link down
IGMP with Query mode for Multi Media Application
2
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP Firmware Update and System Configure Restore and Backup
Provides EFT protection 3,000 VDC for power line
Supports 6,000 VDC Ethernet ESD protection
Software Specification
SNMP v1, v2c and v3 management
Web interface management
Telnet interface management
Command Line Interface (CLI) management
RFC 1215 Trap
Management
RFC 1213 MIBII
RFC 1157 SNMP MIB
RFC 1493 Bridge MIB
SNMP MIB
RFC 2674 VLAN MIB
RFC 1643
RFC 1757
RSTP MIB
Private MIB
Port based VLAN
IEEE802.1Q Tag VLAN (256 entries)/VLAN ID (up to 4k in
number which can be assigned from 1 to 4096)
GVRP (256 groups)
VLAN
Double Tag VLAN (Q in Q)*
Private VLAN**
Port Trunk with
LACP
LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk
members
Supports LLDP that allows the switch to advertise its
identity and capabilities on the LAN
IEEE802.1d spanning tree
IEEE802.1w rapid spanning tree.
Supports X-Ring, Dual Homing, Couple Ring, and Central
Ring
LLDP**
Spanning tree
X-Ring
Manual Documentation Number: EIR618-2SFP-T_5107m
3
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Provides redundant backup feature and the recovery time
below 20ms
The quality of service determined by port, Tag and IPv4
Type of Service, IPv4/IPv6 Different Service
Supports IEEE 802.1p class of service, per port provides 4
priority queues
Quality of service
Class of service
Port Security
Supports 100 entries of MAC address for static MAC and
another 100 for MAC filter
TX packet only
Port mirror
IGMP
RX packet only,
Both of TX and RX packets
Supports IGMP snooping v1, v2 and v3
Up to 256 multicast groups and IGMP query
Supports 10 IP addresses that have permission to access
the switch management and to prevent unauthorized
intruder
IP Security
Login Security
Supports IEEE-802.1X Authentication/RADIUS
Supports ingress packet filter and egress packet limit
The egress rate control supports all of packet type and the
limit rates are 100K ~ 250Mbps
Ingress filter packet type combination rules are
Broadcast/Multicast/Unknown Unicast packet,
Broadcast/Multicast, Broadcast packet only and all of
packets
Bandwidth control
The packet filter rate can be set from 100k to 250Mbps
Supports Flow Control for Full-duplex and Back Pressure
for Half-duplex
Flow Control
System Log
SMTP
Supports System log record and remote system log server
Supports SMTP Server and 6 e-mail accounts for
receiving event alert
Provides one relay output for port breakdown & power fail
Alarm Relay current carry ability: 1A @ DC24V
Relay Alarm
4
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Up to 3 Trap stations
Cold start, Port link up, Port link down, Authentication
Failure, Private Trap for power status, Power Alarm
configuration, Fault Alarm, X-Ring topology change
SNMP Trap
DHCP
Provides DHCP Client/DHCP Server function
Provides DNS client feature
DNS
Supports Primary and Secondary DNS Server
SNTP
Supports SNTP to synchronize system clock in Internet
TFTP firmware update
Firmware update
TFTP backup and restore
Configuration
upload and
download
Supports binary configuration file for system quick
installation
Package Contents
Managed Industrial Switch x 1
Pluggable Terminal Block x 1
CD ROM with User manual x 1
Mounting plate x 2
Console Cable (RJ-45 to DB9-Female) x 1
Manual Documentation Number: EIR618-2SFP-T_5107m
5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Description
Physical Dimension
(W x D x H) 2.83 x 4.13 x 5.98 in (7.2mm x 10.5mm x 15.2 cm)
Front Panel
Front Panel of the industrial switch
6
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Top View
Top Panel of the industrial switch
Manual Documentation Number: EIR618-2SFP-T_5107m
7
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Indicators
LED
Status
Meaning
Green
Off
Power On
PWR
No Power Inputs
Green
The switch is the master of the X-Ring group
R.M.
The industrial switch is not the master of the
X-Ring group
Off
Green
Off
Power Source 1 is Available
Power Source 1 is Unavailable
Power Source 2 is Available
Power Source 2 is Unavailable
Power or port failure
PWR1
PWR2
Fault
Green
Off
Red
Off
Normal Operation
Green
Connected to network
(Upper LED)
Blinking
Network is active
(Upper LED)
Off
Not connected to network
(Upper LED)
P1 through 16
Yellow
Full duplex
(Lower LED)
Blinking
Data packet collision
(Lower LED)
Off
Half duplex or not connected to network
(Lower LED)
P17/18
Green
Connected to network
(10/100/1000T)
(Upper LED)
8
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Blinking
Network is active
(Upper LED)
Off
Not connected to network
(Upper LED)
Green
The port is operating at 1000M
(Lower LED)
Off
The port is disconnected or operating at
(Lower LED) 10/100M
Green
Blinking
Off
SFP port is connected to network
P17 /18
Link/Active
(100/1000 SFP)
Network is active
Not connected to network
Ports
RJ-45 ports
RJ-45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for
10Base-T, 100Base-TX or 1000Base-T devices connections and Auto
MDI/MDIX.
RJ-45 Pin Assignments
Pin Number
Assignment
1
2
3
6
Tx+
Tx-
Rx+
Rx-
Manual Documentation Number: EIR618-2SFP-T_5107m
9
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Straight Through Cable Schematic
Cross Over Cable Schematic
Gigabit Copper/SFP (Mini-GBIC) combo port:
The Industrial switch has auto-detecting Giga—UTP/STP/Fiber combo ports.
The Gigabit Copper (10/100/1000T) ports should use Category 5e or above
UTP/STP cable. The SFP slots are for connecting to the network segment
with single or multi-mode fiber. The small form-factor pluggable (SFP) is a
compact optical transceiver used in optical communications.
Note
When an SFP module is inserted, the associated copper port is
disabled.
10
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Cabling
Twisted-pair segment can be either unshielded twisted pair (UTP) or
shielded twisted pair (STP) cabling. The cable between the link partner
(switch, hub, workstation, etc.) and the converter must be less than 100
meters (328 ft.) long and comply with the IEEE 802.3ab 1000Base-T
standard for Category 5e or above.
Single-mode fiber links must use 9/125μm single-mode fiber cable.
Multi-mode fiber links must use 50/125 or 62.5/125μm multi-mode fiber
cable. The small form-factor pluggable (SFP) is a compact optical
transceiver
To connect the transceiver and LC cable, follow the steps shown below:
First, insert the transceiver into the SFP module. The triangle mark identifies
bottom of the module.
Transceiver to the SFP module
Manual Documentation Number: EIR618-2SFP-T_5107m
11
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Ensure the module is aligned correctly and then slide the module into the
SFP slot until a click is heard.
Transceiver Inserted
Insert the fiber cable into the transceiver.
LC connector to the transceiver
To remove the fiber cable from the transceiver, follow the steps shown
below:
12
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Press the upper side of the LC connector from the transceiver and pull it out
to release.
Remove LC connector
Push down the metal loop and pull the transceiver out by the plastic part.
Pull out from the SFP module
Manual Documentation Number: EIR618-2SFP-T_5107m
13
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring the Power Inputs
Please follow the steps below to insert the power wire.
1. Insert the positive and negative leads into the V+ and V- contacts on the
terminal block connector.
2. To tighten the wire-clamp screws.
14
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring the Fault Alarm Contact
The fault alarm contact is in the middle of terminal block connector.
Note
Use 12 to 24 AWG wire.
Manual Documentation Number: EIR618-2SFP-T_5107m
15
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Installation
DIN-Rail Mounting
Rear Panel of
the switch
DIN-Rail
16
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
1. First, insert the top of the DIN-Rail clip into the track.
2. Then, lightly push into the track.
3. Ensure the DIN-Rail clip is tightly secured to the track.
4. To remove the industrial switch from the track, reverse steps above.
Manual Documentation Number: EIR618-2SFP-T_5107m
17
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Panel Mounting
Follow the steps as below to mount the industrial switch with wall mount plate.
1. Remove the DIN-Rail from the industrial switch.
2. Place the panel mount plate on the rear panel.
3. Use the screws to attach the panel mount.
4. Use the hook holes at the corners of the plate to mount the switch to the.
To remove the wall mount plate, reverse steps above.
18
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Hardware Installation
Installation Steps
1. Unpack the Industrial switch.
2. Ensure the DIN-Rail is tightly screwed to the Industrial switch. If not,
refer to DIN-Rail Mounting section for DIN-Rail installation. To panel
mount the Industrial switch, refer to Panel Mounting section.
3. Apply power to the switch (refer to the Wiring the Power Inputs
section). The power LED will light.
4. Connect CAT 5 cables to the Industrial switch’s RJ-45 ports and to the
network devices
[NOTE] If the network devices do not support MID/MDIX, a
crossover cable may be required.
Manual Documentation Number: EIR618-2SFP-T_5107m
19
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Application
X-Ring Application
This switch incorporates the X-Ring Protocol to ensure network reliability
and system restoration within 300 ms in the event of a connection failure.
The X-Ring algorithm is similar to the spanning tree protocol (STP)
algorithm but it has faster recovery time. The following figure below is an
example of an X-Ring application.
20
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Coupling Ring Application
If the network has more than one X-Ring group, the coupling ring function is
used to connect them and add redundancy. This ensures that transmissions
between the two ring groups will not fail. The figure below is an example of
the coupling ring application.
Manual Documentation Number: EIR618-2SFP-T_5107m
21
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Dual Homing Application
The Dual Homing function is used to prevent a connection loss between the
X-Ring group and the upper level/core switch. Assign a port in each X-ring
group to be the Dual Homing ports The Dual Homing function can only be
used when the X-Ring function is active. Each X-Ring group can have one
Dual Homing port. Note: The upper level switches must have RSTP
enabled.
[NOTE] In Dual Homing application architecture, the upper level switches
must enable the Rapid Spanning Tree protocol.
22
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Console Management
Connecting to the Console Port
Attach the DB9 end to a PC or terminal and the RJ-45 end to the console
port on the switch. The PC must have support a terminal emulation
program.
Pin Assignment
DB9 Connector RJ-45 Connector
NC
2
1
2
3
4
5
6
7
8
Orange/White
Orange
3
Green/White
Blue
NC
5
Blue/White
Green
NC
NC
NC
Brown/White
Brown
Manual Documentation Number: EIR618-2SFP-T_5107m
23
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Login in the Console Interface
When the connection between Switch and PC is ready, turn on the PC, run
a terminal emulation program or Hyper Terminal, and configure the
following communication parameters:
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow control: None
The settings of communication parameters
After entering the parameter, click ‘OK’. When the blank screen shows up,
press Enter on the PC keyboard. A login screen will be displayed. Enter
‘root’ for the User name and Password.
24
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Console login interface
CLI Management
After you login to the system, you will see a command prompt. To enter CLI
management interface, type ‘enable’ and press enter.
CLI command interface
Manual Documentation Number: EIR618-2SFP-T_5107m
25
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Commands Level
Access
Exit
Modes
Prompt
About This Mode
Method
Method
The user commands
available at the user
level are a subset of
those available at the
privileged level.
Begin a
Enter
User EXEC
session with
your switch.
switch>
logout or
quit.
Use this mode to
• Perform basic tests.
• Display system
information.
The privileged
Enter the
command is the
enable
Enter
advanced mode.
Use this mode to
• Display advanced
function status
Privileged
EXEC
command
while in User
EXEC mode.
switch#
disable to
exit.
• Save configuration
Enter the
To exit to
privileged
EXEC
Use this mode to
configure those
configure
command
while in
Global
switch
parameters that are
Configuration
(config)#
mode, enter going to be applied to
privileged
EXEC mode.
Enter the vlan
database
command
while in
exit or end
your switch.
To exit to
Use this mode to
configure
VLAN
switch
(vlan)#
user EXEC
database
mode, enter VLAN-specific
privileged
EXEC mode.
exit.
parameters.
Interface
Enter the
switch
To exit to
Use this mode to
configuration
interface of
(config-if)# global
configure parameters
26
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
fast Ethernet
command
(with a
configuratio
n mode,
for the switch and
Ethernet ports.
enter exit.
To exit to
privileged
EXEC
specific
interface)
while in global
configuration
mode
mode, enter
exit or end.
Commands Set List
User EXEC
E
P
G
V
I
Privileged EXEC
Global configuration
VLAN database
Interface configuration
System Commands Set
Commands
show config
Level Description
Example
E
P
P
Show switch
switch>show config
configuration
Show console
information
show terminal
write memory
switch#show terminal
switch#write memory
Save user
configuration into
permanent memory
(flash rom)
system name
G
G
G
Configure system
name
switch(config)#system name xxx
[System Name]
system location
[System Location]
system description
[System Description]
Set switch system
location string
Set switch system
description string
switch(config)#system location
xxx
switch(config)#system
description xxx
Manual Documentation Number: EIR618-2SFP-T_5107m
27
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
system contact
[System Contact]
show system-info
G
E
Set switch system
switch(config)#system contact
contact window string xxx
Show system
information
switch>show system-info
ip address
[Ip-address]
[Subnet-mask]
[Gateway]
ip dhcp
G
Configure the IP
address of switch
switch(config)#ip address
192.168.1.1 255.255.255.0
192.168.1.254
G
P
Enable DHCP client
function of switch
switch(config)#ip dhcp
show ip
no ip dhcp
reload
Show IP information of switch#show ip
switch
G
G
Disable DHCP client switch(config)#no ip dhcp
function of switch
Halt and perform a cold
restart
switch(config)#reload
default
G
G
Restore to default
Changes a login
username.
switch(config)#default
switch(config)#admin username
xxxxxx
admin username
[Username]
(maximum 10 words)
admin password
[Password]
G
P
Specifies a password switch(config)#admin password
(maximum 10 words) xxxxxx
show admin
Show administrator
information
switch#show admin
dhcpserver enable
Dhcpserver disable
dhcpserver lowip
[Low IP]
G
G
G
Enable DHCP Server switch(config)#dhcpserver enable
Disable DHCP Server switch(config)#no dhcpserver
Configure low IP
address for IP pool
Configure high IP
address for IP pool
Configure subnet
switch(config)#dhcpserver lowip
192.168.1.100
dhcpserver highip
[High IP]
G
G
G
G
switch(config)#dhcpserver highip
192.168.1.200
dhcpserver subnetmask
[Subnet mask]
switch(config)#dhcpserver
mask for DHCP clients subnetmask 255.255.255.0
Configure gateway for switch(config)#dhcpserver
dhcpserver gateway
[Gateway]
DHCP clients
gateway 192.168.1.254
dhcpserver dnsip
Configure DNS IP for switch(config)#dhcpserver dnsip
28
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
[DNS IP]
DHCP clients
Configure lease time switch(config)#dhcpserver
(in hour)
leasetime 1
Set static IP for DHCP switch(config)#interface
192.168.1.1
dhcpserver leasetime
[Hours]
G
I
dhcpserver ipbinding
[IP address]
clients by port
fastEthernet 2
switch(config)#dhcpserver
ipbinding 192.168.1.1
show dhcpserver
configuration
P
P
P
Show configuration of switch#show dhcpserver
DHCP server
configuration
show dhcpserver clients
Show client entries of switch#show dhcpserver clients
DHCP server
show dhcpserver
ip-binding
Show IP-Binding
switch#show dhcpserver
information of DHCP ip-binding
server
no dhcpserver
security enable
security http
G
G
G
G
G
Disable DHCP server switch(config)#no dhcpserver
function
Enable IP security
function
switch(config)#security enable
Enable IP security of switch(config)#security http
HTTP server
security telnet
Enable IP security of switch(config)#security telnet
telnet server
security ip
Set the IP security list switch(config)#security ip 1
192.168.1.55
[Index(1..10)] [IP
Address]
show security
P
G
G
G
Show the information switch#show security
of IP security
no security
Disable IP security
function
switch(config)#no security
no security http
no security telnet
Disable IP security of switch(config)#no security http
HTTP server
Disable IP security of switch(config)#no security telnet
telnet server
Manual Documentation Number: EIR618-2SFP-T_5107m
29
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Commands Set
Commands
interface fastEthernet
[Portid]
Level Description
Example
G
Choose the port for
switch(config)#interface
fastEthernet 2
modification.
duplex
I
Use the duplex
configuration
switch(config)#interface
fastEthernet 2
[full | half]
command to specify
the duplex mode of
operation for Fast
Ethernet.
switch(config-if)#duplex full
speed
I
Use the speed
switch(config)#interface
fastEthernet 2
[10|100|1000|auto]
configuration
command to specify
the speed mode of
operation for Fast
Ethernet., the speed
can’t be set to 1000 if
the port isn’t a giga
port..
switch(config-if)#speed 100
no flowcontrol
security enable
I
I
Disable flow control of switch(config-if)#no flowcontrol
interface
Enable security of
interface
switch(config)#interface
fastEthernet 2
switch(config-if)#security enable
switch(config)#interface
fastEthernet 2
no security
I
I
Disable security of
interface
switch(config-if)#no security
bandwidth type all
Set interface ingress switch(config)#interface
limit frame type to
“accept all frame”
fastEthernet 2
switch(config-if)#bandwidth type
all
bandwidth type
I
Set interface ingress switch(config)#interface
broadcast-multicast-floo
ded-unicast
limit frame type to
“accept broadcast,
fastEthernet 2
switch(config-if)#bandwidth type
30
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
multicast, and flooded broadcast-multicast-flooded-uni
unicast frame”
cast
Set interface ingress switch(config)#interface
limit frame type to
fastEthernet 2
“accept broadcast and switch(config-if)#bandwidth type
multicast frame”
broadcast-multicast
Set interface ingress switch(config)#interface
limit frame type to
fastEthernet 2
“only accept broadcast switch(config-if)#bandwidth type
bandwidth type
I
I
I
broadcast-multicast
bandwidth type
broadcast-only
frame”
broadcast-only
bandwidth in
[Value]
Set interface input
bandwidth. Rate
Range is from 100
kbps to 102400 kbps
or to 256000 kbps for
giga ports,
switch(config)#interface
fastEthernet 2
switch(config-if)#bandwidth in 100
and zero means no
limit.
bandwidth out
[Value]
Set interface output
bandwidth. Rate
Range is from 100
switch(config)#interface
fastEthernet 2
switch(config-if)#bandwidth out
kbps to 102400 kbps 100
or to 256000 kbps for
giga ports,
and zero means no
limit.
show bandwidth
I
I
Show interfaces
switch(config)#interface
bandwidth control
fastEthernet 2
switch(config-if)#show bandwidth
state
Use the state interface switch(config)#interface
configuration
fastEthernet 2
[Enable | Disable]
command to specify (config-if)#state Disable
the state mode of
Manual Documentation Number: EIR618-2SFP-T_5107m
31
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
operation for Ethernet
ports. Use the disable
form of this command
to disable the port.
show interface
show interface
configuration
I
switch(config)#interface
fastEthernet 2
configuration status
switch(config-if)#show interface
configuration
show interface status
I
I
show interface actual switch(config)#interface
status
fastEthernet 2
(config-if)#show interface status
show interface
accounting
show interface statistic switch(config)#interface
counter
fastEthernet 2
(config-if)#show interface
accounting
no accounting
I
Clear interface
switch(config)#interface
accounting information fastEthernet 2
switch(config-if)#no accounting
Trunk Commands Set
Commands
Level Description
Example
aggregator priority
[1~65535]
G
Set port group system switch(config)#aggregator priority
priority
22
aggregator activityport
[Group ID]
G
Set activity port
switch(config)#aggregator
activityport 2
[Port Numbers]
aggregator group
[GroupID] [Port-list]
lacp
G
Assign a trunk group switch(config)#aggregator group
with LACP active.
[GroupID] :1~3
1 1-4 lacp workp 2
or
workp
[Port-list]:Member port switch(config)#aggregator group
[Workport]
list, This parameter
could be a port
2 1,4,3 lacp workp 3
range(ex.1-4) or a port
list separate by a
32
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
comma(ex.2, 3, 6)
[Workport]: The
amount of work ports,
this value could not be
less than zero or be
large than the amount
of member ports.
aggregator group
[GroupID] [Port-list]
nolacp
G
Assign a static trunk switch(config)#aggregator group
group.
1 2-4 nolacp
[GroupID] :1~3
or
[Port-list]:Member port switch(config)#aggregator group
list, This parameter
could be a port
1 3,1,2 nolacp
range(ex.1-4) or a port
list separate by a
comma(ex.2, 3, 6)
show aggregator
P
Show the information switch#show aggregator 1
of trunk group
or
switch#show aggregator 2
or
switch#show aggregator 3
switch(config)#no aggreator lacp
no aggregator lacp
[GroupID]
G
G
Disable the LACP
function of trunk group 1
no aggregator group
[GroupID]
Remove a trunk group switch(config)#no aggreator
group 2
VLAN Commands Set
Commands
Level Description
Example
vlan database
P
Enter VLAN configure switch#vlan database
mode
Vlanmode
V
To set switch VLAN
mode.
switch(vlan)#vlanmode portbase
[portbase| 802.1q |
gvrp]
or
switch(vlan)#vlanmode 802.1q
Manual Documentation Number: EIR618-2SFP-T_5107m
33
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
or
switch(vlan)#vlanmode gvrp
Switch(vlan)#no vlan
no vlan
V
No VLAN
Ported based VLAN configuration
vlan port-based
grpname
V
Add new port based switch(vlan)#vlan port-based
VALN
grpname test grpid 2 port 2-4
or
[Group Name]
grpid
switch(vlan)#vlan port-based
grpname test grpid 2 port 2,3,4
[GroupID]
port
[PortNumbers]
show vlan [GroupID]
or
show vlan
no vlan group
[GroupID]
V
V
Show VLAN
information
switch(vlan)#show vlan 23
Delete port base group switch(vlan)#no vlan group 2
ID
IEEE 802.1Q VLAN
vlan 8021q name
[GroupName]
vid
V
V
V
V
Change the name of switch(vlan)#vlan 8021q name
VLAN group, if the
group didn’t exist, this
command can’t be
applied.
test vid 22
[VID]
vlan 8021q port
[PortNumber]
access-link untag
[UntaggedVID]
Assign an access link switch(vlan)#vlan 8021q port 3
for VLAN by port, if the access-link untag 33
port belongs to a trunk
group, this command
can’t be applied.
vlan 8021q port
[PortNumber]
trunk-link tag
Assign a trunk link for switch(vlan)#vlan 8021q port 3
VLAN by port, if the
trunk-link tag 2,3,6,99
[TaggedVID List]
port belongs to a trunk or
group, this command switch(vlan)#vlan 8021q port 3
can’t be applied.
Assign a hybrid link for switch(vlan)#vlan 8021q port 3
VLAN by port; if the
hybrid-link untag 4 tag 3,6,8
port belongs to a trunk or
trunk-link tag 3-20
vlan 8021q port
[PortNumber]
hybrid-link untag
[UntaggedVID]
tag
34
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
[TaggedVID List]
group, this command switch(vlan)#vlan 8021q port 3
can’t be applied.
hybrid-link untag 5 tag 6-8
Assign a access link switch(vlan)#vlan 8021q trunk 3
vlan 8021q trunk
[PortNumber]
access-link untag
[UntaggedVID]
V
V
for VLAN by trunk
group
access-link untag 33
vlan 8021q trunk
[PortNumber]
trunk-link tag
Assign a trunk link for switch(vlan)#vlan 8021q trunk 3
VLAN by trunk group trunk-link tag 2,3,6,99
or
[TaggedVID List]
switch(vlan)#vlan 8021q trunk 3
trunk-link tag 3-20
vlan 8021q trunk
[PortNumber]
hybrid-link untag
[UntaggedVID]
tag
V
Assign a hybrid link for switch(vlan)#vlan 8021q trunk 3
VLAN by trunk group hybrid-link untag 4 tag 3,6,8
or
switch(vlan)#vlan 8021q trunk 3
hybrid-link untag 5 tag 6-8
[TaggedVID List]
show vlan [GroupID]
or
show vlan
no vlan group
[GroupID]
V
Show VLAN
information
switch(vlan)#show vlan 23
V
Delete port base group switch(vlan)#no vlan group 2
ID
Spanning Tree Commands Set
Commands
Level Description
Example
Enable spanning tree switch(config)#spanning-tree
enable
spanning-tree enable
G
G
G
spanning-tree priority
[0~61440]
Configure spanning
switch(config)#spanning-tree
tree priority parameter priority 32767
spanning-tree max-age
[seconds]
Use the spanning-tree switch(config)#spanning-tree
max-age global
max-age 15
configuration
command to change
the interval between
messages the
spanning tree receives
Manual Documentation Number: EIR618-2SFP-T_5107m
35
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
from the root switch. If
a switch does not
receive a bridge
protocol data unit
(BPDU) message from
the root switch within
this interval, it
recomputed the
Spanning Tree
Protocol (STP)
topology.
spanning-tree
G
Use the spanning-tree switch(config)#spanning-tree
hello-time [seconds]
hello-time global
hello-time 3
configuration
command to specify
the interval between
hello bridge protocol
data units (BPDUs).
spanning-tree
G
Use the spanning-tree switch(config)#spanning-tree
forward-time [seconds]
forward-time global
configuration
forward-time 20
command to set the
forwarding-time for the
specified
spanning-tree
instances. The
forwarding time
determines how long
each of the listening
and learning states
last before the port
begins forwarding.
stp-path-cost
[1~200000000]
I
Use the spanning-tree switch(config)#interface
cost interface
fastEthernet 2
36
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
configuration
switch(config-if)#stp-path-cost 20
command to set the
path cost for Spanning
Tree
Protocol (STP)
calculations. In the
event of a loop,
spanning tree
considers the path
cost when selecting
an interface to place
into the forwarding
state.
stp-path-priority
[Port Priority]
I
Use the spanning-tree switch(config)#interface
port-priority interface fastEthernet 2
configuration
switch(config-if)#stp-path-priority
command to configure 128
a port priority that
is used when two
switches tie for
position as the root
switch.
stp-admin-p2p
I
I
I
Admin P2P of STP
priority on this
interface.
switch(config)#interface
[Auto|True|False]
fastEthernet 2
switch(config-if)#stp-admin-p2p
Auto
stp-admin-edge
[True|False]
Admin Edge of STP
priority on this
interface.
switch(config)#interface
fastEthernet 2
switch(config-if)#stp-admin-edge
True
stp-admin-non-stp
[True|False]
Admin NonSTP of STP switch(config)#interface
priority on this
interface.
fastEthernet 2
switch(config-if)#stp-admin-non-s
Manual Documentation Number: EIR618-2SFP-T_5107m
37
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
tp False
Displays a summary of switch>show spanning-tree
the spanning-tree
show spanning-tree
E
states.
no spanning-tree
G
Disable spanning-tree. switch(config)#no spanning-tree
QOS Commands Set
Commands
Level Description
Example
qos policy
G
Select QOS policy
scheduling
switch(config)#qos policy
weighted-fair
[weighted-fair|strict]
qos prioritytype
G
Setting of QOS priority switch(config)#qos prioritytype
[port-based|cos-only|tos
-only|cos-first|tos-first]
type
qos priority portbased
[Port]
G
Configure Port-based switch(config)#qos priority
Priority
portbased 1 low
[lowest|low|middle|high]
qos priority cos
[Priority][lowest|low|mid
dle|high]
G
G
Configure COS Priority switch(config)#qos priority cos 0
middle
Configure TOS Priority
switch(config)#
qos priority tos 3
qos priority tos
high
[Priority][lowest|low|mid
dle|high]
show qos
P
Displays the
Switch#
show qos
information of QoS
configuration
no qos
G
Disable QoS function
switch(config)#
no qos
IGMP Commands Set
Commands
igmp enable
Level Description
Example
G
G
G
Enable IGMP
switch(config)#igmp enable
snooping function
Set IGMP query to
auto mode
Igmp-query auto
Igmp-query force
38
switch(config)#Igmp-query auto
switch(config)#Igmp-query force
Set IGMP query to
force mode
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
show igmp
P
P
Displays the details of switch#show igmp configuration
configuration
an IGMP
configuration.
show igmp multi
Displays the details of switch#show igmp multi
an IGMP snooping
entries.
no igmp
G
G
Disable IGMP
switch(config)#no igmp
snooping function
no igmp-query
Disable IGMP query switch#no igmp-query
Mac / Filter Table Commands Set
Commands
mac-address-table static
hwaddr
Level Description
Example
I
Configure MAC
address table of
interface (static).
switch(config)#interface
fastEthernet 2
[MAC]
switch(config-if)#mac-address-tab
le static hwaddr 000012345678
switch(config)#mac-address-table
filter hwaddr 000012348678
mac-address-table filter
hwaddr
G
Configure MAC
address table(filter)
[MAC]
show mac-address-table
P
P
P
I
Show all MAC address switch#show mac-address-table
table
show mac-address-table
static
Show static MAC
address table
switch#show mac-address-table
static
show mac-address-table
filter
Show filter MAC
address table.
switch#show mac-address-table
filter
no mac-address-table
static hwaddr
[MAC]
Remove an entry of
switch(config)#interface
MAC address table of fastEthernet 2
interface (static)
switch(config-if)#no
mac-address-table static hwaddr
000012345678
no mac-address-table
filter hwaddr
[MAC]
G
Remove an entry of
MAC address table
(filter)
switch(config)#no
mac-address-table filter hwaddr
000012348678
Manual Documentation Number: EIR618-2SFP-T_5107m
39
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
no mac-address-table
G
Remove dynamic entry switch(config)#no
of MAC address table mac-address-table
SNMP Commands Set
Commands
Level Description
Example
snmp system-name
[System Name]
snmp system-location
[System Location]
snmp system-contact
[System Contact]
snmp agent-mode
[v1v2c|v3|v1v2cv3]
snmp
G
Set SNMP agent
system name
switch(config)#snmp
system-name l2switch
switch(config)#snmp
system-location lab
switch(config)#snmp
system-contact where
G
G
G
G
Set SNMP agent
system location
Set SNMP agent
system contact
Select the agent mode switch(config)#snmp agent-mode
of SNMP
v1v2cv3
Add SNMP community switch(config)#snmp
community-strings
[Community]
string.
community-strings public right
rw
right
[RO/RW]
snmp-server host
[IP address]
G
Configure SNMP
switch(config)#snmp-server host
server host information 192.168.1.50 community public
and community string trap-version v1
(remove)
community
[Community-string]
trap-version
Switch(config)#
[v1|v2c]
no snmp-server host
192.168.1.50
snmpv3 context-name
[Context Name ]
snmpv3 user
[User Name]
G
G
Configure the context switch(config)#snmpv3
name
context-name Test
Configure the
userprofile for
SNMPV3 agent.
Privacy password
could be empty.
switch(config)#snmpv3 user
test01 group G1 password
AuthPW PrivPW
group
[Group Name]
password
[Authentication
Password] [Privacy
40
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Password]
snmpv3 access
context-name [Context
Name ]
G
Configure the access switch(config)#snmpv3 access
table of SNMPV3
agent
context-name Test group G1
security-level AuthPriv
group
match-rule Exact views V1 V1 V1
[Group Name ]
security-level
[NoAuthNoPriv|AuthNoP
riv|AuthPriv]
match-rule
[Exact|Prifix]
views
[Read View Name] [Write
View Name] [Notify View
Name]
snmpv3 mibview view
[View Name]
type
G
Configure the mibview switch(config)#snmpv3 mibview
table of SNMPV3
agent
view V1 type Excluded sub-oid
1.3.6.1
[Excluded|Included]
sub-oid
[OID]
show snmp
P
Show SNMP
configuration
switch#show snmp
no snmp
G
Remove the specified switch(config)#no snmp
community-strings
[Community]
community.
community-strings public
no snmp-server host
[Host-address]
no snmpv3 user
[User Name]
G
G
G
Remove the SNMP
server host.
switch(config)#no snmp-server
192.168.1.50
Remove specified user switch(config)#no snmpv3 user
of SNMPv3 agent.
Remove specified
access table of
Test
no snmpv3 access
context-name [Context
Name ]
switch(config)#no snmpv3 access
context-name Test group G1
security-level AuthPr
SNMPv3 agent.
Manual Documentation Number: EIR618-2SFP-T_5107m
41
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
group
iv match-rule Exact views V1 V1
V1
[Group Name ]
security-level
[NoAuthNoPriv|AuthNoP
riv|AuthPriv]
match-rule
[Exact|Prifix]
views
[Read View Name] [Write
View Name] [Notify View
Name]
no snmpv3 mibview
view
G
Remove specified
mibview table of
SNMPV3 agent.
switch(config)#no snmpv3
mibview view V1 type Excluded
sub-oid 1.3.6.1
[View Name]
type
[Excluded|Included]
sub-oid
[OID]
Port Mirroring Commands Set
Commands
monitor
Level Description
Example
I
Configure source port switch(config)#interface
[RX|TX|Both]
of monitor function
fastEthernet 2
switch(config-if)#monitor RX
switch(config)#monitor rx 2
monitor rx [Port ID]
monitor tx [Port ID]
show monitor
G
G
P
I
Set RX destination
port of monitor function
Set TX destination port switch(config)#monitor tx 3
of monitor function
Show port monitor
information
switch#show monitor
show monitor
Show port monitor
information
switch(config)#interface
fastEthernet 2
switch(config-if)#show monitor
no monitor
I
Disable source port of switch(config)#interface
42
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
monitor function
fastEthernet 2
switch(config-if)#no monitor
802.1x Commands Set
Commands
Level Description
Example
8021x enable
G
Use the 802.1x global switch(config)# 8021x enable
configuration
command to enable
802.1x protocols.
8021x system radiusip
[IP address]
G
Use the 802.1x system switch(config)# 8021x system
radius IP global
radiusip 192.168.1.1
configuration
command to change
the radius server IP.
8021x system serverport
[port ID]
G
G
G
G
Use the 802.1x system switch(config)# 8021x system
server port global
configuration
serverport 1815
command to change
the radius server port
8021x system
accountport
[port ID]
Use the 802.1x system switch(config)# 8021x system
account port global
configuration
accountport 1816
command to change
the accounting port
8021x system sharekey
[ID]
Use the 802.1x system switch(config)# 8021x system
share key global
configuration
sharekey 123456
command to change
the shared key value.
8021x system nasid
[words]
Use the 802.1x system switch(config)# 8021x system
nasid global
nasid test1
configuration
command to change
Manual Documentation Number: EIR618-2SFP-T_5107m
43
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
the NAS ID
8021x misc quietperiod
[sec.]
G
Use the 802.1x misc switch(config)# 8021x misc
quiet period global
configuration
quietperiod 10
command to specify
the quiet period value
of the switch.
8021x misc txperiod
[sec.]
G
G
G
G
G
I
Use the 802.1x misc switch(config)# 8021x misc
TX period global
configuration
txperiod 5
command to set the
TX period.
8021x misc
Use the 802.1x misc switch(config)# 8021x misc
supportimeout [sec.]
supp timeout global
configuration
supportimeout 20
command to set the
supplicant timeout.
8021x misc
Use the 802.1x misc switch(config)#8021x misc
server timeout global servertimeout 20
configuration
servertimeout [sec.]
command to set the
server timeout.
8021x misc maxrequest
[number]
Use the 802.1x misc switch(config)# 8021x misc
max request global
configuration
maxrequest 3
command to set the
MAX requests.
8021x misc
Use the 802.1x misc switch(config)# 8021x misc
reauthperiod [sec.]
reauth period global
configuration
reauthperiod 3000
command to set the
reauth period.
8021x portstate
Use the 802.1x port
state interface
switch(config)#interface
[disable | reject | accept |
fastethernet 3
44
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
authorize]
configuration
switch(config-if)#8021x portstate
command to set the
state of the selected
port.
accept
show 8021x
E
Displays a summary of switch>show 8021x
the 802.1x properties
and also the port
sates.
no 8021x
G
Disable 802.1x
function
switch(config)#no 8021x
TFTP Commands Set
Commands
backup
Level Description
Defaults Example
switch(config)#backup
flash:backup_cfg
G
G
G
Save configuration to
flash:backup_cfg
TFTP and need to
specify the IP of TFTP
server and the file name
of image.
restore flash:restore_cfg
Get configuration from switch(config)#restore
TFTP server and need to flash:restore_cfg
specify the IP of TFTP
server and the file name
of image.
upgrade
Upgrade firmware by
TFTP and need to
specify the IP of TFTP
server and the file name
of image.
switch(config)#upgrade
flash:upgrade_fw
lash:upgrade_fw
SystemLog, SMTP and Event Commands Set
Commands
systemlog ip
[IP address]
Level Description
Example
G
Set System log server switch(config)# systemlog ip
IP address.
192.168.1.100
Manual Documentation Number: EIR618-2SFP-T_5107m
45
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
systemlog mode
[client|server|both]
show systemlog
show systemlog
G
Specified the log mode switch(config)# systemlog mode
both
E
P
Displays system log. Switch>show systemlog
Show system log client switch#show systemlog
& server information
no systemlog
G
Disable systemlog
functon
switch(config)#no systemlog
smtp enable
G
G
Enable SMTP function switch(config)#smtp enable
smtp serverip
[IP address]
Configure SMTP
server IP
switch(config)#smtp serverip
192.168.1.5
smtp authentication
G
G
G
Enable SMTP
authentication
Configure
switch(config)#smtp
authentication
smtp account
[account]
switch(config)#smtp account
authentication account John
smtp password
[password]
Configure
switch(config)#smtp password
1234
authentication
password
smtp rcptemail
[Index] [Email address]
show smtp
G
P
Configure Rcpt e-mail switch(config)#smtp rcptemail 1
Address
Show the information switch#show smtp
of SMTP
no smtp
G
G
Disable SMTP function switch(config)#no smtp
event device-cold-start
[Systemlog|SMTP|Both]
event
Set cold start event
type
switch(config)#event
device-cold-start both
switch(config)#event
G
G
I
Set Authentication
failure event type
authentication-failure
[Systemlog|SMTP|Both]
event
authentication-failure both
Set X-ring topology
changed event type
switch(config)#event
ring-topology-change
[Systemlog|SMTP|Both]
event systemlog
[Link-UP|Link-Down|Bot
h]
ring-topology-change both
Set port event for
system log
switch(config)#interface
fastethernet 3
switch(config-if)#event systemlog
both
46
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
event smtp
I
Set port event for
SMTP
switch(config)#interface
fastethernet 3
[Link-UP|Link-Down|Bot
h]
switch(config-if)#event smtp both
show event
P
Show event selection switch#show event
no event
G
Disable cold start
event type
switch(config)#no event
device-cold-start
no event
device-cold-start
G
G
Disable Authentication switch(config)#no event
authentication-failure
no event
failure event typ
Disable X-ring
topology changed
event type
authentication-failure
switch(config)#no event
X-ring-topology-change
X-ring-topology-change
no event systemlog
I
Disable port event for switch(config)#interface
system log
fastethernet 3
switch(config-if)#no event
systemlog
no event smpt
I
Disable port event for switch(config)#interface
SMTP
fastethernet 3
switch(config-if)#no event smtp
show systemlog
P
Show system log client switch#show systemlog
& server information
SNTP Commands Set
Commands
sntp enable
Level Description
Example
G
G
Enable SNTP function switch(config)#sntp enable
sntp daylight
Enable daylight saving switch(config)#sntp daylight
time, if SNTP function
is inactive, this
command can’t be
applied.
sntp daylight-period
[Start time] [End time]
G
Set period of daylight switch(config)# sntp
saving time, if SNTP daylight-period 20060101-01:01
function is inactive,
20060202-01:01
this command can’t be
Manual Documentation Number: EIR618-2SFP-T_5107m
47
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
applied.
Parameter format:
[yyyymmdd-hh:mm]
sntp daylight-offset
[Minute]
G
Set offset of daylight switch(config)#sntp
saving time, if SNTP daylight-offset 3
function is inactive,
this command can’t be
applied.
sntp ip
[IP]
G
G
Set SNTP server IP, if switch(config)#sntp ip 192.169.1.1
SNTP function is
inactive, this command
can’t be applied.
sntp timezone
[Timezone]
Set timezone index,
use “show sntp
timzezone” command
to get more
switch(config)#sntp timezone 22
information of index
number
show sntp
P
P
Show SNTP
switch#show sntp
information
show sntp timezone
Show index number of switch#show sntp timezone
time zone list
no sntp
G
G
Disable SNTP function switch(config)#no sntp
Disable daylight saving switch(config)#no sntp daylight
time
no sntp daylight
X-ring Commands Set
Commands
Level Description
Example
Xring enable
G
Enable X-ring
switch(config)#Xring enable
switch(config)#Xring master
switch(config)#Xring couplering
switch(config)#Xring dualhoming
switch(config)#Xring ringport 7 8
Xring master
G
G
G
G
Enable ring master
Enable couple ring
Enable dual homing
Configure 1st/2nd
Ring Port
Xring couplering
Xring dualhoming
Xring ringport
[1st Ring Port] [2nd Ring
48
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port]
Xring couplingport
[Coupling Port]
Xring controlport
[Control Port]
Xring homingport
[Dual Homing Port]
show Xring
G
G
G
P
Configure Coupling
Port
switch(config)#Xring couplingport
1
Configure Control Port switch(config)#Xring controlport 2
Configure Dual
Homing Port
switch(config)#Xring homingport
3
Show the information switch#show Xring
of X - Ring
no Xring
G
G
G
Disable X-ring
switch(config)#no X ring
switch(config)# no Xring master
switch(config)# no Xring
couplering
no Xring master
no Xring couplering
Disable ring master
Disable couple ring
no Xring dualhoming
G
Disable dual homing switch(config)# no Xring
dualhoming
Manual Documentation Number: EIR618-2SFP-T_5107m
49
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Web-Based Management
About Web-based Management
The switch has an embedded HTML web site residing in flash memory. This
site offers advanced management features and allows the switch to be
configured from anywhere on the network.
The web site is designed for Internet Explorer 6.0 and uses Java Applets to
reduce bandwidth consumption, enhance access speed, and present an
intuitive user interface.
Preparing for Web Management
Before using web management, install the industrial switch on the network
and verify that a PC on the local network can connect with the switch
through the web browser. The default IP Address, Subnet Mask, Username
and Password is listed below:
IP Address: 192.168.16.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.16.254
User Name: root
Password: root
50
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
System Login
1. Launch Internet Explorer on the PC
2. Key in “http:// “+” the IP address of the switch”, and then Press “Enter”.
3. The login screen will appear
4. Enter the user name and password. The default user name and
password are ‘root’
5. Press ‘Enter‘ or click OK button, and then the home screen of the
Web-based management appears.
Manual Documentation Number: EIR618-2SFP-T_5107m
51
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
System Information
System Name: A name (64 bytes max) can be assigned to the switch.
System Description: Displays the description of switch. Read only
cannot be modified
System Location: A physical location (64 bytes max) can be assigned
to the switch.
System Contact: Enter the name of contact person or organization
Firmware Version: Displays the switch’s firmware version
Kernel Version: Displays the kernel software version
MAC Address: Displays the unique hardware address assigned by
manufacturer (default)
Apply
Click
.
System information interface
52
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
IP Configuration
Configure the IP Settings and DHCP client function
DHCP Client: Used to enable or disable the DHCP client function.
When enabled, the switch’s IP address is assigned by the network
DHCP server. The default IP address will be replace by the DHCP
server assigned IP address. After clicking the ‘Apply’ button, a popup
dialog will indicate that the current IP will be lost and the new IP
address must be retrieved from the DHCP server.
IP Address: A static IP Address may be assigned. The default IP is
192.168.16.1.
Subnet Mask: Assign the subnet mask of the IP address. This does
not have to be done if the DHCP client function is enabled.
Gateway: Assign the network gateway. The default gateway is
192.168.16.254.
DNS1: Assign the primary DNS IP address.
DNS2: Assign the secondary DNS IP address.
Apply
Click
IP configuration interface
Manual Documentation Number: EIR618-2SFP-T_5107m
53
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
DHCP Server – System configuration
The switch can function as a DHCP server.
DHCP Server: Enable or Disable the DHCP Server function.
Low IP Address: the dynamic IP assign range. Low IP address is the
beginning of the dynamic IP assignment range.
High IP Address: the dynamic IP assign range. High IP address is the
end of the dynamic IP assignment range.
Subnet Mask: The subnet mask.
Gateway: The network gateway.
DNS: Network Domain Name Server IP Address.
Lease Time (sec): The time interval at which that system will reset the
dynamic IP assignment.
Apply
Click
DHCP Server Configuration interface
DHCP Server – Client Entries
DHCP Client information is displayed.
54
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
DHCP Client Entries interface
DHCP Server - Port and IP Bindings
You can assign a specific IP address that is in the dynamic IP assignment
range to the specific port. When the device is connected to the port and
asks for an assignment, the system will assign this IP address.
Port and IP Bindings interface
Manual Documentation Number: EIR618-2SFP-T_5107m
55
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP - Update Firmware
Provides the ability to update the switch’s firmware. Before updating, ensure
you the TFTP server is ready and the firmware image is on the TFTP server.
1. TFTP Server IP Address: Enter the TFTP server IP.
2. Firmware File Name: Enter the name of firmware image.
Apply
3. Click
.
Update Firmware interface
TFTP – Restore Configuration
If the EEPROM image is stored on the TFTP server, you can restore it to
flash memory.
1. TFTP Server IP Address: Enter the TFTP server IP.
2. Restore File Name: Enter the restore file name.
Apply
3. Click
.
Restore Configuration interface
56
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
TFTP - Backup Configuration
You can save current EEPROM image to the TFTP server.
1. TFTP Server IP Address: Enter the TFTP server IP
2.
Enter the file name
Backup File Name:
Apply
3. Click
.
Backup Configuration interface
System Event Log – Syslog Configuration
Configure the system event mode to collect system log.
1. Syslog Client Mode: Select the system log mode – client only, server
only, or both.
2. System Log Server IP Address: Assigned the system log server IP
Reload
3. Click
4. Click
to refresh the event log.
Clear
to clear all current event log.
Apply
5. After configuring, Click
.
Manual Documentation Number: EIR618-2SFP-T_5107m
57
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Syslog Configuration interface
System Event Log - SMTP Configuration
Set up the mail server IP, mail account, account password, and email
account for receiving event alerts.
1. Email Alert: enable or disable the email alert function.
2. SMTP Server IP: set up the mail server IP address.
where the event log came from.
4. Authentication: Mark the check box to enable and configure the email
account and password for authentication.
5. Mail Account: set up the email account, e.g. johnadmin for the switch.
It must be an existing email account on the mail server.
58
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Password: The email account password.
7. Confirm Password: reconfirm the password.
8. Rcpt e-mail Address 1 through 6: Enter up to six email addresses to
receive the event log.
Apply
9. Click
button.
SMTP Configuration interface
System Event Log - Event Configuration
When the selected events occur, the system will generate a log entry and
email notification message. .
System event selection: Four selections available – Cold Start, Warm
Start, SNMP Authentication Failure, and X-ring topology change. Mark
the checkbox to select the event. When the selected events occur, the
system will send the logs.
Manual Documentation Number: EIR618-2SFP-T_5107m
59
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port event selection: When a port specific event occurs, the system
will generate a log entry and email notification. Three selections are
available – Link UP, Link Down, and Link UP & Link Down.
Event Configuration interface
60
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Fault Relay Alarm
Power Failure: When the check box is marked, the Fault LED will light
if the power source fails.
Port Link Down/Broken: When the check box is marked, the Fault
LED will light if a port link goes down.
Fault Relay Alarm interface
SNTP Configuration
The SNTP allows you to synchronize switch clocks.
1. SNTP Client: Enables or disables the SNTP function.
2. Daylight Saving Time: Enables or disables daylight saving time. When
this function is enabled, the time period must be entered.
3. UTC Time zone: Sets the local time zone.
Manual Documentation Number: EIR618-2SFP-T_5107m
61
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Local Time Zone
November Time Zone
Oscar Time Zone
Conversion from UTC
- 1 hour
Time at 12:00 UTC
11am
10 am
9 am
-2 hours
ADT - Atlantic Daylight
-3 hours
AST - Atlantic Standard
EDT - Eastern Daylight
EST - Eastern Standard
CDT - Central Daylight
CST - Central Standard
MDT - Mountain Daylight
MST - Mountain
-4 hours
-5 hours
-6 hours
8 am
7 am
6 am
Standard
-7 hours
5 am
PDT - Pacific Daylight
PST - Pacific Standard
ADT - Alaskan Daylight
-8 hours
-9 hours
-10 hours
-11 hours
4 am
3 am
2 am
1 am
ALA - Alaskan Standard
HAW - Hawaiian
Standard
Nome, Alaska
CET - Central European
FWT - French Winter
MET - Middle European
MEWT - Middle
+1 hour
1 pm
European Winter
SWT - Swedish Winter
EET - Eastern European,
Russia Zone 1
+2 hours
+3 hours
2 pm
3 pm
BT - Baghdad, Russia
Zone 2
62
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
ZP4 - Russia Zone 3
ZP5 – Russia Zone 4
ZP6 - Russia Zone 5
+4 hours
+5 hours
+6 hours
4 pm
5 pm
6 pm
WAST - West Australian
Standard
+7 hours
+8 hours
+9 hours
7 pm
8 pm
9 pm
CCT - China Coast,
USSR Zone 7
JST - Japan Standard,
Russia Zone 8
EAST - East Australian
Standard GST
+10 hours
+12 hours
10 pm
Guam Standard, Russia
Zone 9
IDLE - International Date
Line
NZST - New Zealand
Standard
Midnight
NZT - New Zealand
4. SNTP Sever URL: Enter the SNTP server IP address.
5. Daylight Saving Period: Enter the Daylight Saving beginning time and
Daylight Saving end time.
6. Daylight Saving Offset (mins): Enter the offset in minutes.
7. Switch Timer: Displays the current time.
Apply
8. Click
.
Manual Documentation Number: EIR618-2SFP-T_5107m
63
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
SNTP Configuration interface
IP Security
IP security function grants 10 specific IP addresses permission to access
the switch through a web browser or TELNET for management.
IP Security Mode: When enabled, allows management via TELNET
and HTTP.
Enable HTTP Server: Mark the box to grant the specified IP addresses
web based management permission.
Enable Telnet Server: Mark the box to grant the specified IP
addresses TELNET management permission.
Security IP 1 ~ 10: Enter up to 10 IP addresses.
Apply
Click
[NOTE]
If the configuration is not saved, it will be lost when the
switch is powered off.
64
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
IP Security interface
User Authentication
Use this function to change the login name and password.
1. User name: Enter the new user name (The default is ‘root’).
2. Password: Enter the new password (The default is ‘root’).
3. Confirm password: Confirm the new password.
Apply
4. Click
User Authentication interface
Manual Documentation Number: EIR618-2SFP-T_5107m
65
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Statistics
Provides port status.
Port: The port number.
Type: Displays the connection speed.
Link: Displays link status —‘Up’ or ‘Down’.
State: Enabled or Disabled.
Tx Good Packet: Displays the number of good packets transmitted.
Tx Bad Packet: Displays the number of bad packets transmitted.
Rx Good Packet: Displays the number of good packets received.
Rx Bad Packet: Displays the number of bad packets received.
Tx Abort Packet: Displays the number of aborted transmit packets.
Packet Collision: Displays the number of packet collisions.
Packet Dropped: Displays the number of dropped packets.
Rx Bcast Packet: Displays the number of broadcast packets.
Displays the number of multicast packets.
Rx Mcast Packet:
Clear
Click
button to reset the numbers.
Port Statistics interface
66
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Control
Used to configure and view port settings.
1. Port: Select the port to configure.
2. State: Enable or disable the port.
3. Negotiation: Set the negotiation status of the port.
4. Speed: Set the port link speed.
5. Duplex: Set the port to full or half-duplex.
6. Flow Control: Set flow control to Symmetric or Asymmetric in Full
Duplex mode. The default value is Symmetric.
7. Security: Set the port security. When ‘On’ is selected, the port will only
accept a connection from one MAC address.
Apply
8. Click
Manual Documentation Number: EIR618-2SFP-T_5107m
67
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Control interface
Port Trunk
The Link Aggregation Control Protocol (LACP) provides a standardized
method for exchanging information between Partner Systems on a link. This
allows their Link Aggregation Control instances to reach an agreement on
the identity of the Link Aggregation Group, move the link to that Link
Aggregation Group, and enable its transmission and reception functions in
an orderly manner. Link aggregation lets you group up to four consecutive
ports into two dedicated connections. This feature expands bandwidth to a
device on the network. LACP operation requires full-duplex mode.
Aggregator setting
1. System Priority: a value used to identify the active LACP. The switch
with the lowest value has the highest priority. It is selected as the active
LACP.
2.
There are four trunk groups available. Choose the "
Group ID:
Group
Select
" and click
ID
3. LACP: If enabled, the group is an LACP static trunk group. If disabled,
the group is local static trunk group. All ports support LACP dynamic
trunk. If connected to a device that also supports LACP, the LACP
dynamic trunk group is automatically created.
4. Work ports: A maximum of four ports can be aggregated at the same
time. With LACP static trunk group, any excess ports are considered
standby and can be aggregated if a work port fails. If it is local static
trunk group, the number of ports must be the same as the group
member ports.
Add
5. Select the ports to add to the trunk group. Click
button to add
the port. To remove unwanted ports, select the port and click
Remove
button.
68
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
6. When LACP enabled, you can configure LACP Active/Passive status
for each port on State Activity page.
Apply
7. Click
Delete
8. Use
to delete Trunk Group.
Port Trunk—Aggregator setting interface (four ports are added to the left field with LACP
enabled)
Manual Documentation Number: EIR618-2SFP-T_5107m
69
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Aggregator Information
Displays static trunk group information.
Port Trunk—Aggregator setting interface (two ports are added to the left field with LACP
disable)
Port Trunk – Aggregator Information interface
State Activity
After setting up the LACP aggregator, port state activity can be configured.
Apply
Mark the port and click
. The port state activity will change to Active
or Passive depending on its previous state.
Active: The port automatically sends LACP protocol packets.
Passive: The port responds only if it receives LACP protocol packets
from the opposite device.
70
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
[NOTE]
1. A link having either two active LACP ports or one
active port can perform dynamic LACP trunk.
2. A link, which has two passive LACP ports, will not
perform dynamic LACP trunk because both ports are
waiting for an LACP protocol packet from the opposite
device.
Port Trunk – State Activity interface
Manual Documentation Number: EIR618-2SFP-T_5107m
71
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Port Mirroring
Port mirroring is a method to monitor traffic in switched networks. Traffic
flowing through the indicated ports can be monitored by a specified port.
Port Trunk – Port Mirroring interface
Destination Port: Only one port can be selected as the destination
(mirror) port for monitoring both RX and TX traffic from the source port.
Two ports may be configured to monitor RX and TX traffic separately. A
LAN analyzer can be connected to the mirror port.
Source Port: Select the ports to monitor. All monitored port traffic will
be sent to the mirror (destination) port. Multiple source ports by can be
selected by checking the RX or TX check boxes.
Apply
Click
72
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Rate Limiting
You can set up every port’s frame limitation type and bandwidth rate.
Rate Limiting interface
All the ports support port ingress and egress rate control. For example,
assume port 1 is 10Mbps, users can set its effective egress rate to
1Mbps, and ingress rate is 500Kbps. The switch performs the ingress
rate limiting using a packet counter to meet the specified rate
Enter the port effective ingress rate(The default value is ‘0’)
Enter the port effective egress rate(The default value is ‘0’)
Ingress:
Egress:
Apply
Click
Manual Documentation Number: EIR618-2SFP-T_5107m
73
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN configuration
A Virtual LAN (VLAN) can be thought of as a broadcast domain that exists
within a switch or a defined set of switches. By grouping switch ports into
VLANs, traffic flooding is limited since devices can only communicate
directly with devices belonging to the VLAN. Creating a VLAN from a switch
is the logical equivalent of reconnecting a group of devices to another Layer
2 switch. However, the network devices retain their same physical
connection. The switch supports port-based and 802.1Q (tagged-based)
VLAN. In the default configuration, the VLAN option is disabled
The switch supports Port-based and 802.1Q (tagged-based) VLAN. The
default configuration of VLAN operation mode is “Disable”.
VLAN Configuration interface
VLAN configuration - Port-based VLAN
With port-based VLAN, the port is assigned to a VLAN. Therefore, all
devices attached to a given port should be members of the same VLAN. As
with other VLAN configurations, the packets forwarded using this method do
not leak into other VLAN domains on the network. After the port has been
assigned to a VLAN, devices on the port cannot send to or receive from
devices in other VLANs without the intervention of another layer 3 device or
the ability to tag the data packet with a specific PVID
74
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN – Port Based interface
Apply
Pull down the selection item for
then press
button
Port Based
Add
Click
to add a new VLAN group (64 groups maximum).
VLAN—Port Based Add interface
Manual Documentation Number: EIR618-2SFP-T_5107m
75
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
VLAN—Port Based Edit/Delete interface
Delete
Edit
Use
Use
button to delete the VLAN.
button to modify group name, VLAN ID, or add/remove the
members of the existing VLAN group.
[NOTE] If the configuration is not saved, it will be lost when the port is
powered off.
76
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
802.1Q VLAN
Tagged-based VLAN is an IEEE 802.1Q specification, which allows VLANs
to be created across devices from different venders. IEEE 802.1Q VLAN
uses a technique to insert a “tag” into the Ethernet frame. The tag contains a
VLAN Identifier (VID).
When the 802.1Q VLAN is enabled, all ports on the switch belong to a
default VLAN (VID 1). The default VLAN cannot be deleted. Up to 64 VLAN
groups are supported.
802.1Q Configuration
1. Enable GVRP Protocol: check the check box to enable GVRP
protocol.
2. Select the port to configure.
3. Link Type: there are three link types.
Access Link: Single switch only. Allows ports to be grouped by
setting the same VID.
Trunk Link: Extended application of Access Link. Allows ports to
be grouped by setting the same VID on two or more switches.
Hybrid Link: Both Access Link and Trunk Link.
4. Untagged VID: assign the untagged frame VID.
5. Tagged VID: assign the tagged frame VID.
Manual Documentation Number: EIR618-2SFP-T_5107m
77
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
802.1Q VLAN interface
Group Configuration
Edit the existing VLAN Group.
Select the VLAN group in the table list.
Edit
Click
button.
78
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Group Configuration interface
You can modify the VLAN group name and VLAN ID.
Group Configuration interface
Apply
Click
button.
Manual Documentation Number: EIR618-2SFP-T_5107m
79
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Rapid Spanning Tree
The Rapid Spanning Tree Protocol (RSTP) is an evolution of Spanning Tree
Protocol (STP). It provides a faster spanning tree convergence after a
topology change. The switch will auto detect a device that is running STP or
RSTP protocol.
RSTP - System Configuration
Apply
After modification, click
¾
¾
RSTP mode: Enable or disable the RSTP.
Priority (0-61440): a value used to identify the root bridge. The
bridge with the lowest value has the highest priority and is selected
as the root. If the value changes, the switch must be rebooted. The
value must be multiple of 4096.
¾
¾
¾
Max Age (6-40): The number of seconds a bridge waits without
receiving Spanning-tree Protocol configuration messages before
attempting a reconfiguration. Enter a value between 6 through 40
Hello Time (1-10): The time that controls when, the switch sends
out the BPDU packet to check RSTP status. Enter a value between
1 and 10.
Forward Delay Time (4-30): the number of seconds a port waits
before changing from its Rapid Spanning Tree Protocol learning
and listening state to the forwarding state. Enter a value between 4
and 30.
[NOTE]
Follow this rule to configure the MAX Age, Hello Time, and
Forward Delay Time.
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x
(Hello Time value +1)
80
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
RSTP System Configuration interface
RSTP - Port Configuration
Configure path cost and priority of each port.
1. Select the port in Port column.
1. Path Cost: The cost of the path to the other bridge from this transmitting
bridge at the specified port. Enter a number 1 through 200000000.
2. Priority: Network priority. Enter a number between 0 and 240. The value
must be a multiple of 16.
3. P2P: Some of the rapid state transactions that are possible within RSTP
are dependent upon whether the port concerned can only be connected
to exactly one other bridge (i.e. it is served by a point-to-point LAN
segment), or can be connected to two or more bridges (i.e. it is served
by a shared medium LAN segment). This function allows the P2P status
of the link to be manipulated administratively. True is P2P enabled.
Manual Documentation Number: EIR618-2SFP-T_5107m
81
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
False is P2P disabled.
4. Edge: The port directly connected to the end stations cannot create a
bridging loop in the network. To configure the port as an edge port, set
the port to ‘True’ status.
Non STP: Set True to disable STP mathematic calculation. Set False
to including the STP mathematic calculation.
Apply
Click
.
RSTP Port Configuration interface
82
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP Configuration
Simple Network Management Protocol (SNMP) is the protocol developed to
manage nodes (servers, workstations, routers, switches, hubs, etc.) on an
IP network. SNMP enables network administrators to manage network
performance, find and solve network problems, and plan for network growth.
Network management systems learn of problems by receiving traps or
change notices from network devices implementing SNMP.
System Configuration
Community Strings
Define and remove community strings.
1. String: Enter the name of the string.
2. RO: Read only. Enables requests accompanied by this string to display
MIB-object information.
3. RW: Read write. Enables requests accompanied by this string to
display MIB-object information and to set MIB objects
Add
4. Click
button.
5. To remove the community string, select the community string and
Remove
click
. The default community string cannot be edited.
Select the SNMP version that you want to use and click
Agent Mode:
Change
Manual Documentation Number: EIR618-2SFP-T_5107m
83
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP System Configuration interface
Trap Configuration
A trap manager is a management station that receives traps (the system
alerts generated by the switch). If the trap manager is not defined, traps will
not be issued. Create a trap manager by entering the IP address of the
station and a community string.
1. IP Address: Enter the IP address of the trap manager.
2.
3.
Enter the community string.
Community:
Select the SNMP trap version type (v1 or v2c).
Trap Version:
Add
4. Click
5. To remove the community string, select the community and click
Remove
.
84
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Trap Managers interface
SNMPV3 Configuration
Context Table
Configure SNMP v3 context table. Assign the context name of context table.
Add
Remove
Click
to add context name. Click
to remove the
unwanted context name.
User Profile
Configure SNMP v3 user table.
User ID: Enter the user name.
Authentication Password: Enter the authentication password.
Privacy Password: Enter the private password.
Add
Click
Click
to add the context name.
Remove
to remove an unwanted context name.
Manual Documentation Number: EIR618-2SFP-T_5107m
85
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
SNMP V3 configuration interface
86
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Group Table
Configure SNMP v3 group table.
Security Name (User ID): Assign the user name that you set up in the
user table.
Group Name: Set up the group name.
Add
Click
Click
to add the context name.
Remove
to remove an unwanted context name.
Access Table
Configure SNMP v3 access table.
Context Prefix: Set up the context name.
Group Name: Set up the group.
Security Level: Set up the access level.
Context Match Rule: Select the context match rule.
Read View Name: Set up the read view.
Write View Name: Set up the write view.
Notify View Name: Set up the notify view.
Add
Click
Click
to add the context name.
Remove
to remove an unwanted context name.
MIBview Table
Configure MIB view table.
ViewName: Set up the name.
Sub-Oid Tree: Fill the Sub OID.
Type: Select the type—excluded or included.
Add
Click
to add the context name.
Manual Documentation Number: EIR618-2SFP-T_5107m
87
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Remove
Click
to remove an unwanted context name.
QoS Configuration
QoS Policy and Priority Type
QoS Policy: select the QoS policy rule.
¾
Use an 8,4,2,1 weighted fair queuing scheme: The switch will
follow 8:4:2:1 rate to process the priority queue from the highest to
the lowest queue. For example, when processing, 1 frame of the
lowest queue, 2 frames of the low queue, 4 frames of the middle
queue, and 8 frames of the high queue will be processed at the
same time.
¾
Use the strict priority scheme: The highest queue will always
processed first.
Priority Type: there are five priority selections available.
Port-base: the port priority will follow the assigned Port-base – High,
middle, low, or lowest.
¾
¾
¾
¾
COS Only: the port priority will only follow the COS priority
assigned.
TOS only: the port priority will only follow the TOS priority
assigned.
COS first: the port priority will follow the COS priority first, and
then the other priority rule.
TOS first: the port priority will follow the TOS priority first, and then
the other priority rule.
Apply
Click
.
88
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
QoS Configuration interface
Port-based Priority
Port x: Each port has 4 priority levels—High, Middle, Low, and
Lowest—to select from.
Manual Documentation Number: EIR618-2SFP-T_5107m
89
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Apply
Click
button to make the settings effective.
COS Configuration
Set up the COS priority level.
COS priority: Set up the COS priority level 0 to 7 –High, Middle, Low,
Lowest.
Apply
Click
.
TOS Configuration
TOS priority: the system provides 0 to 63 TOS priority levels. Each
level has four types of priority – high, middle, low, and lowest. The default
value is ‘Lowest’. When an IP packet is received, the system will check the
TOS level value in the IP packet. For example, if the TOS level 25 is high
and the port is following the TOS priority policy only, when a packet is
received, the system will check the TOS value of the received IP packet. If
the TOS value of received IP packet is 25(priority = high), then the packet
will have highest priority.
Apply
Click
button to make the settings effective.
IGMP Configuration
The Internet Group Management Protocol (IGMP) is an internal protocol of
the Internet Protocol (IP) suite. IP manages multicast traffic by using
switches, routers, and hosts that support IGMP. Enabling IGMP allows the
ports to detect IGMP queries and report packets and manage IP multicast
traffic through the switch. IGMP has three fundamental types of message.
90
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Message
Query
Description
A message sent from the querier (IGMP router or switch)
asking for a response from each host belonging to the
multicast group.
A message sent by a host to the querier to indicate that the
host wants to be or is a member of a given group indicated in
the report message.
Report
A message sent by a host to the querier to indicate that the
host has quit being a member of a specific multicast group.
Leave
Group
Enable IGMP protocol on the web management switch setting advanced
page. IP multicast addresses range from 224.0.0.0 through
239.255.255.255.
IGMP Protocol: Enable or disable the IGMP protocol.
Select the IGMP query function (Enable or Auto) to set
IGMP Query:
the switch as a querier for an IGMP version 2 multicast network.
Apply
Click
button.
IGMP Configuration interface
Manual Documentation Number: EIR618-2SFP-T_5107m
91
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
X-Ring
X-Ring provides network redundancy similar to the Spanning Tree and
Rapid Spanning Tree Protocols. However, recovery time is greatly reduced
when the X-Ring protocol is used. The protocol identifies one switch as the
Ring Master. Packets are blocked from the redundant path unless a ring
member becomes disconnected from the rest of the network. When this
happens, the protocol automatically restores connectivity using the
redundant path.
In the X-Ring topology, every switch should enable X-Ring function and
assign two member ports to the ring. Only one switch in the X-Ring group
would be set as the backup switch. Other switches are called working
switches and their two member ports are called working ports. If a network
connection failure occurs, the backup port will automatically become a
working port to recover.
The switch can be set in the ring master or slave mode. The ring master
negotiates and places commands to the other switches in the X-Ring group.
If there are two or more switches in the master mode, the software will
select the switch with lowest MAC address number as the ring master. The
X-Ring master mode is enabled using the X-Ring configuration interface.
The Ring Master can also be identified using the R.M. LED on the front of
the switch.
The switch also supports coupling ring to connect two or more X-Ring
groups for redundant backup. The dual homing function is used to prevent a
connection lose between the X-Ring group and the upper level/core switch.
Enable X-Ring: Mark the check box to enable the X-Ring function.
Enable Ring Master: Mark the check box to set the switch as the Ring
Master.
1st & 2nd Ring Ports: Assign two ports as the member ports. 1st Ring
Port is the working port and 2nd Ring Port is the backup port. When 1st
Ring Port fails, the system will automatically upgrade the 2nd Ring
Port to be the working port.
92
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Enable Coupling Ring: Mark the check box to enable the coupling ring
function.
Coupling port: Assign the member port.
Control port: Set the switch as the master switch in the coupling ring.
Enable Dual Homing: Set up one of port on the switch to be the Dual Homing
port. In an X-Ring group, only one port can be the Dual Homing port. Dual
Homing only works when the X-Ring function is enabled.
Apply
Click
.
X-ring Interface
[NOTE]
1. When the X-Ring function is enabled, disable RSTP.
2. If the configuration is not saved, it will be lost when the switch
is powered off.
Manual Documentation Number: EIR618-2SFP-T_5107m
93
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Security
802.1X/Radius Configuration
802.1x is an IEEE authentication specification that allows a client to connect
to a wireless access point or wired switch but prevents the client from
gaining access to the Internet until it proves authority by providing a user
name and password, which is verified by a separate server.
System Configuration
1. IEEE 802.1x Protocol: Enable or disable 802.1x protocol.
2. Radius Server IP: Enter the Radius Server IP address.
3. Server Port: Enter the UDP destination port for authentication requests
to the Radius Server.
4. Accounting Port: Enter the UDP destination port for accounting
requests to the Radius Server.
5. Shared Key: Enter an encryption key for use during authentication
sessions. This key must match the encryption key used on the Radius
Server
6. NAS, Identifier: Enter the identifier of the radius client.
Apply
7. Click
802.1x System Configuration interface
94
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
802.1x Port Configuration
You can configure 802.1x authentication state for each port. The State
choices are Disable, Accept, Reject and Authorize. Use the ‘Space’ key
change the state value.
Reject: The port is held in the unauthorized state.
Accept: The port is held in the Authorized state.
Authorized: The port will allow an authentication exchange between
the supplicant and the authentication server.
Disable: The port is held in the Authorized state
Apply
Click
.
802.1x Per Port Setting interface
Manual Documentation Number: EIR618-2SFP-T_5107m
95
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Misc Configuration
Quiet Period: Sets the period during which the port does not try to
acquire a supplicant.
TX Period: Sets the period that the port waits before retransmitting the
next EAPOL PDU during an authentication session.
Supplicant Timeout: Sets the period the switch waits for a supplicant
response to an EAP request.
Server Timeout: Set the period the switch waits for a server response
to an authentication request.
Max Requests: Sets the number of authentications that time-out
before authentication fails and the authentication session ends.
Reauth period: Set the period of time after which connected clients
must be re-authenticated.
Apply
Click
.
802.1x Misc Configuration interface
96
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
MAC Address Table
Use the MAC address table to ensure the port security.
Static MAC Address
You can add a static MAC address. This address remains in the switch's
address table, regardless of whether the device is physically connected to
the switch. Therefore, the switch does not have to re-learn a device's MAC
address when the disconnected or powered-off device reconnects to the
network. You can add / modify / delete a static MAC address.
Add the Static MAC Address
You can add static MAC address in the switch MAC table here.
MAC Address: Enter the MAC address of the port that should
permanently forward traffic, regardless of the device network activity.
Port No.: Pull down the selection menu to select the port number.
Add
Click
button.
If you want to delete the MAC address from filtering table, select the
Delete
MAC address and click
button.
Manual Documentation Number: EIR618-2SFP-T_5107m
97
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Static MAC Addresses interface
MAC Filtering
MAC Filtering interface
1. MAC Address: Enter the MAC address that you want to filter.
Add
2. Click
button.
3. If you want to delete the MAC address from the filtering table, select the
Delete
MAC address and click
button.
98
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
All MAC Addresses
You can view the port that connected device’s MAC address and the related
devices’ MAC address.
1. Select the port.
2. The selected port static & dynamic MAC address information will be
displayed.
Clear MAC Table
3. Click
to clear the port static MAC address.
All MAC Address interface
Factory Default
Reset
To reset switch to the default configuration, click
. This function has
the option of retaining the current IP address and username/password.
Manual Documentation Number: EIR618-2SFP-T_5107m
99
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Factory Default interface
Save Configuration
Save
Click
to save the configuration to the flash memory.
Save Configuration interface
System Reboot
Reboot
Click
to reboot the system.
System Reboot interface
100
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Trouble shooting
Verify that 12 to 48VDC power is available. Do not exceed 48VDC.
Select the proper cable to construct your network. Use unshielded
twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections:
100Ω Category 3, 4, or 5 cable for 10Mbps connections, 100Ω Category 5
cable for 100Mbps, or 100Ω Category 5e/above cable for 1000Mbps
connections. Ensure that the length of any twisted-pair connection does not
exceed 100 meters (328 feet).
LED Indicators: The LEDs can be used to diagnose system problems
Manual Documentation Number: EIR618-2SFP-T_5107m
101
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specification
IEEE 802.3 10Base-T
IEEE 802.3u 100Base-TX
IEEE 802.3ab 1000Base-T
IEEE 802.3z Gigabit fiber
IEEE 802.3x Flow Control and Back-pressure
IEEE 802.3ad Port trunk with LACP
IEEE 802.1d Spanning Tree
Standard
IEEE 802.1w Rapid Spanning Tree
IEEE 802.1p Class of Service
IEEE 802.1Q VLAN Tag
IEEE 802.1x User Authentication (RADIUS)
Protocol
CSMA/CD
14,880 pps for 10Base-T Ethernet port
Transfer Rate
148,800 pps for 100Base-TX/FX Fast Ethernet port
1,488,000 pps for Gigabit Fiber Ethernet port
MAC address
Packet Buffer
8K MAC address table
1Mbits
Per unit: Power (Green), Power 1 (Green), Power 2
(Green), Fault (Red), Master (Green)
16 10/100TX: Link/Activity (Green), Full duplex/Collision
(Yellow)
LED
Gigabit Copper: Link/Activity (Green), Speed (1000M
Green)
SFP: Link/Activity (Green)
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable
EIA/TIA-568 100-ohm (100m)
Network Cable
100Base-TX: 2-pair UTP/STP Cat. 5 cable
EIA/TIA-568 100-ohm (100m)
102
Manual Documentation Number: EIR618-2SFP-T_5107m
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
1000Base-T: 2-pair UTP/STP Cat. 5e or 6 cable
EIA/TIA-568 100-ohm (100m)
LC (Multi-mode): 50/125um or 62.5/125um
LC (Single mode): 9/125um
Optical cable
Back-plane
7.2Gbps
Packet throughput
ability
10.7Mpps at 64bytes
12 to 48 VDC
Power Supply
Redundant power with reverse polarity protection and
removable terminal block
Power
11.2 Watts
Consumption
Install
DIN Rail and Wall Mount Design
Operation Temp.
-40oC to 75oC
Operation
Humidity
Storage
5% to 95% (Non-condensing)
-40oC to 85oC
Temperature
Case Dimension
IP-30, 72 mm (W) x 105 mm (D) x 152mm (H)
FCC Class A
CE EN61000-4-2 (ESD)
CE EN61000-4-3 (RS)
CE EN61000-4-4 (EFT)
CE EN61000-4-5 (Surge)
CE EN61000-4-6 (CS)
CE EN61000-4-8
EMI
Manual Documentation Number: EIR618-2SFP-T_5107m
103
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com
Download from Www.Somanuals.com. All Manuals Search And Download.
CE EN61000-4-11
CE EN61000-4-12
CE EN61000-6-2
CE EN61000-6-4
Safety
CE/EN60950-1
IEC60068-2-32 (Free fall)
IEC60068-2-27 (Shock)
IEC60068-2-6 (Vibration)
Stability testing
104
Manual Documentation Number: EIR618-2SFP-T_5107m