BB Electronics Computer Drive EIR618 2SFP T User Manual

Product Description  
Model EIR618-2SFP-T  
Documentation Number: EIR618-2SFP-T_5107m  
707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA  
Phone (815) 433-5100 -- General Fax (815) 433-5105  
Phone (815) 433-5100 -- General Fax (815) 433-5105  
Website: www.bb-elec.com  
Sales e-mail: [email protected] -- Fax (815) 433-5109  
Technical Support e-mail: [email protected] -- Fax (815) 433-5104  
European Headquarters  
B&B Electronics  
Westlink Commercial Park -- Oranmore, Co. Galway, Ireland  
Phone +353 91-792444 -- Fax +353 91-792445  
Website: www.bb-europe.com  
Sales e-mail: [email protected]  
Technical Support e-mail: [email protected]  
B&B Electronics Mfg. Co. Inc. -- December 2007  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Eighteen Port Managed Industrial  
Ethernet Switches  
User Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notice  
The contents of this manual are based on the firmware, kernel  
version, and hardware version listed below.  
Firmware Version  
Kernel Version  
V1.07  
V2.07  
Hardware Version  
----------  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC Warning  
This Equipment has been tested and found to comply with the limits for a  
Class-A digital device, pursuant to Part 15 of the FCC rules. These limits are  
designed to provide reasonable protection against harmful interference in a  
residential installation. This equipment generates, uses, and can radiate  
radio frequency energy. It may cause harmful interference to radio  
communications if the equipment is not installed and used in accordance  
with the instructions. However, there is no guarantee that interference will  
not occur in a particular installation. If this equipment does cause harmful  
interference to radio or television reception, which can be determined by  
turning the equipment off and on, the user is encouraged to try to correct the  
interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to  
which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
CE Mark Warning  
This is a Class-A product. In a domestic environment, this product may cause  
radio interference in which case the user may be required to take adequate  
measures.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Content  
Introduction................................................................ 1  
Features ................................................................... 1  
Software Specification.............................................. 3  
Package Contents.................................................... 5  
Hardware Description................................................ 6  
Physical Dimension.................................................. 6  
Front Panel............................................................... 6  
Top View .................................................................. 7  
LED Indicators.......................................................... 8  
Ports......................................................................... 9  
Cabling ................................................................... 11  
Wiring the Power Inputs......................................... 14  
Wiring the Fault Alarm Contact .............................. 15  
Mounting Installation............................................... 16  
DIN-Rail Mounting.................................................. 16  
Wall Mount Plate Mounting .................................... 18  
Hardware Installation .............................................. 19  
Network Application................................................ 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X-Ring Application.................................................. 20  
Coupling Ring Application...................................... 21  
Dual Homing Application........................................ 22  
Console Management.............................................. 23  
Connecting to the Console Port ............................. 23  
Pin Assignment ...................................................... 23  
Login in the Console Interface ............................... 24  
CLI Management.................................................... 25  
Commands Level .............................................................26  
Commands Set List..........................................................27  
System Commands Set....................................................27  
Port Commands Set.........................................................30  
Trunk Commands Set ......................................................32  
VLAN Commands Set ......................................................33  
Spanning Tree Commands Set........................................35  
QOS Commands Set........................................................38  
IGMP Commands Set ......................................................38  
Mac / Filter Table Commands Set....................................39  
SNMP Commands Set .....................................................40  
Port Mirroring Commands Set..........................................42  
802.1x Commands Set.....................................................43  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP Commands Set.......................................................45  
SystemLog, SMTP and Event Commands Set.................45  
SNTP Commands Set......................................................47  
X-ring Commands Set......................................................48  
Web-Based Management ........................................ 50  
About Web-based Management ............................ 50  
Preparing for Web Management............................ 50  
System Login.......................................................... 51  
System Information ................................................ 52  
IP Configuration ..................................................... 52  
DHCP Server – System configuration.................... 54  
DHCP Server – Client Entries................................ 54  
DHCP Server - Port and IP Bindings ..................... 55  
TFTP - Update Firmware ....................................... 56  
TFTP – Restore Configuration ............................... 56  
TFTP - Backup Configuration................................. 57  
System Event Log – Syslog Configuration............. 57  
System Event Log - SMTP Configuration .............. 58  
System Event Log - Event Configuration ............... 59  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fault Relay Alarm................................................... 61  
SNTP Configuration ............................................... 61  
IP Security.............................................................. 64  
User Authentication................................................ 65  
Port Statistics ......................................................... 66  
Port Control............................................................ 67  
Port Trunk............................................................... 68  
Aggregator setting............................................................68  
Aggregator Information.....................................................70  
State Activity.....................................................................70  
Port Mirroring.......................................................... 72  
Rate Limiting .......................................................... 73  
VLAN configuration ................................................ 74  
VLAN configuration - Port-based VLAN ...........................74  
802.1Q VLAN ...................................................................77  
Rapid Spanning Tree ............................................. 80  
RSTP - System Configuration ..........................................80  
RSTP - Port Configuration................................................81  
SNMP Configuration .............................................. 83  
System Configuration.......................................................83  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trap Configuration............................................................84  
SNMPV3 Configuration ....................................................85  
QoS Configuration.................................................. 88  
QoS Policy and Priority Type ...........................................88  
Port-based Priority............................................................89  
COS Configuration ...........................................................90  
TOS Configuration............................................................90  
IGMP Configuration................................................ 90  
X-Ring .................................................................... 92  
Security .................................................................. 94  
802.1X/Radius Configuration ...........................................94  
MAC Address Table .........................................................97  
Factory Default....................................................... 99  
Save Configuration............................................... 100  
System Reboot..................................................... 100  
Trouble shooting.................................................... 101  
Technical Specification......................................... 102  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
This managed industrial switch comes equipped with a proprietary  
redundant network protocol—X-Ring which provides an easy way to  
establish a redundant Ethernet network. With ultra high-speed recovery time  
(less than 300 ms) and a long MTBF (Mean Time Between Failures) the  
industrial switch will continue to operate until a Gigabit network infrastructure  
has been established, without requiring extra upgrade costs.  
In addition to 10/100/1000Base-TX fast Ethernet ports, the switch has SFP  
(mini-GBIC) ports. Traditional RJ-45 ports can be used for up linking short  
distance (less than 100 m) wide-band paths, while the SFP slots can be  
used for the application of wideband uploading and long distance  
transmissions adding flexibility  
Features  
System Interface/Performance  
¾
¾
¾
¾
¾
¾
¾
RJ-45 ports support Auto MDI/MDI-X Function  
SFP (mini-GBIC) supports 100/1000 Dual Mode  
Store-and-Forward Switching Architecture  
Back-plane (Switching Fabric): 7.2Gbps  
1Mbits Packet Buffer  
8K MAC Address Table  
Wide Operating Temperature (-40oC to 75oC)*  
Case/Installation  
¾
¾
IP-30  
DIN-Rail and Panel Mount  
Power Supply  
¾
¾
¾
Wide Range Redundant Power Design  
Reverse Polarity Protection  
Current Overload Protection  
Manual Documentation Number: EIR618-2SFP-T_5107m  
1
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Spanning Tree  
¾
¾
IEEE 802.1d Spanning Tree  
IEEE 802.1w Rapid Spanning Tree  
VLAN  
¾
¾
¾
Port Based VLAN  
802.1 Q Tag VLAN  
GVRP  
X-Ring  
¾
X-Ring, Dual Homing, Couple Ring, and Central Ring Topology  
Port Trunk with LACP  
QoS (Quality of Service)  
¾
¾
¾
IEEE 802.1p Class of Service  
Four priority queues per port  
Port Base, Tag Base and Type of Service Priority  
Bandwidth Control  
¾
¾
Ingress Packet Filter and Egress Rate Limit  
Broadcast/Multicast Packet Filter Control  
Port Mirror: Monitor traffic in switched networks  
¾
¾
¾
TX Packet only  
RX Packet only  
Both of TX and RX Packet  
System Event Log  
¾
¾
¾
System Log Server/Client  
SMTP e-mail Alert  
Relay Alarm Output System Events  
Security  
¾
¾
¾
Port Security : MAC address entries/filter  
IP Security: IP address security management to prevent intrusion  
Login Security: IEEE802.1X/RADIUS  
SNMP Trap  
¾
¾
¾
¾
Cold Start, Power status  
Authentication failure  
X-Ring topology change  
Link up / Link down  
IGMP with Query mode for Multi Media Application  
2
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP Firmware Update and System Configure Restore and Backup  
Provides EFT protection 3,000 VDC for power line  
Supports 6,000 VDC Ethernet ESD protection  
Software Specification  
SNMP v1, v2c and v3 management  
Web interface management  
Telnet interface management  
Command Line Interface (CLI) management  
RFC 1215 Trap  
Management  
RFC 1213 MIBII  
RFC 1157 SNMP MIB  
RFC 1493 Bridge MIB  
SNMP MIB  
RFC 2674 VLAN MIB  
RFC 1643  
RFC 1757  
RSTP MIB  
Private MIB  
Port based VLAN  
IEEE802.1Q Tag VLAN (256 entries)/VLAN ID (up to 4k in  
number which can be assigned from 1 to 4096)  
GVRP (256 groups)  
VLAN  
Double Tag VLAN (Q in Q)*  
Private VLAN**  
Port Trunk with  
LACP  
LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk  
members  
Supports LLDP that allows the switch to advertise its  
identity and capabilities on the LAN  
IEEE802.1d spanning tree  
IEEE802.1w rapid spanning tree.  
Supports X-Ring, Dual Homing, Couple Ring, and Central  
Ring  
LLDP**  
Spanning tree  
X-Ring  
Manual Documentation Number: EIR618-2SFP-T_5107m  
3
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Provides redundant backup feature and the recovery time  
below 20ms  
The quality of service determined by port, Tag and IPv4  
Type of Service, IPv4/IPv6 Different Service  
Supports IEEE 802.1p class of service, per port provides 4  
priority queues  
Quality of service  
Class of service  
Port Security  
Supports 100 entries of MAC address for static MAC and  
another 100 for MAC filter  
TX packet only  
Port mirror  
IGMP  
RX packet only,  
Both of TX and RX packets  
Supports IGMP snooping v1, v2 and v3  
Up to 256 multicast groups and IGMP query  
Supports 10 IP addresses that have permission to access  
the switch management and to prevent unauthorized  
intruder  
IP Security  
Login Security  
Supports IEEE-802.1X Authentication/RADIUS  
Supports ingress packet filter and egress packet limit  
The egress rate control supports all of packet type and the  
limit rates are 100K ~ 250Mbps  
Ingress filter packet type combination rules are  
Broadcast/Multicast/Unknown Unicast packet,  
Broadcast/Multicast, Broadcast packet only and all of  
packets  
Bandwidth control  
The packet filter rate can be set from 100k to 250Mbps  
Supports Flow Control for Full-duplex and Back Pressure  
for Half-duplex  
Flow Control  
System Log  
SMTP  
Supports System log record and remote system log server  
Supports SMTP Server and 6 e-mail accounts for  
receiving event alert  
Provides one relay output for port breakdown & power fail  
Alarm Relay current carry ability: 1A @ DC24V  
Relay Alarm  
4
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Up to 3 Trap stations  
Cold start, Port link up, Port link down, Authentication  
Failure, Private Trap for power status, Power Alarm  
configuration, Fault Alarm, X-Ring topology change  
SNMP Trap  
DHCP  
Provides DHCP Client/DHCP Server function  
Provides DNS client feature  
DNS  
Supports Primary and Secondary DNS Server  
SNTP  
Supports SNTP to synchronize system clock in Internet  
TFTP firmware update  
Firmware update  
TFTP backup and restore  
Configuration  
upload and  
download  
Supports binary configuration file for system quick  
installation  
Package Contents  
Managed Industrial Switch x 1  
Pluggable Terminal Block x 1  
CD ROM with User manual x 1  
Mounting plate x 2  
Console Cable (RJ-45 to DB9-Female) x 1  
Manual Documentation Number: EIR618-2SFP-T_5107m  
5
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Description  
Physical Dimension  
(W x D x H) 2.83 x 4.13 x 5.98 in (7.2mm x 10.5mm x 15.2 cm)  
Front Panel  
Front Panel of the industrial switch  
6
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Top View  
Top Panel of the industrial switch  
Manual Documentation Number: EIR618-2SFP-T_5107m  
7
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LED Indicators  
LED  
Status  
Meaning  
Green  
Off  
Power On  
PWR  
No Power Inputs  
Green  
The switch is the master of the X-Ring group  
R.M.  
The industrial switch is not the master of the  
X-Ring group  
Off  
Green  
Off  
Power Source 1 is Available  
Power Source 1 is Unavailable  
Power Source 2 is Available  
Power Source 2 is Unavailable  
Power or port failure  
PWR1  
PWR2  
Fault  
Green  
Off  
Red  
Off  
Normal Operation  
Green  
Connected to network  
(Upper LED)  
Blinking  
Network is active  
(Upper LED)  
Off  
Not connected to network  
(Upper LED)  
P1 through 16  
Yellow  
Full duplex  
(Lower LED)  
Blinking  
Data packet collision  
(Lower LED)  
Off  
Half duplex or not connected to network  
(Lower LED)  
P17/18  
Green  
Connected to network  
(10/100/1000T)  
(Upper LED)  
8
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Blinking  
Network is active  
(Upper LED)  
Off  
Not connected to network  
(Upper LED)  
Green  
The port is operating at 1000M  
(Lower LED)  
Off  
The port is disconnected or operating at  
(Lower LED) 10/100M  
Green  
Blinking  
Off  
SFP port is connected to network  
P17 /18  
Link/Active  
(100/1000 SFP)  
Network is active  
Not connected to network  
Ports  
RJ-45 ports  
RJ-45 ports (Auto MDI/MDIX): The RJ-45 ports are auto-sensing for  
10Base-T, 100Base-TX or 1000Base-T devices connections and Auto  
MDI/MDIX.  
RJ-45 Pin Assignments  
Pin Number  
Assignment  
1
2
3
6
Tx+  
Tx-  
Rx+  
Rx-  
Manual Documentation Number: EIR618-2SFP-T_5107m  
9
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Straight Through Cable Schematic  
Cross Over Cable Schematic  
Gigabit Copper/SFP (Mini-GBIC) combo port:  
The Industrial switch has auto-detecting Giga—UTP/STP/Fiber combo ports.  
The Gigabit Copper (10/100/1000T) ports should use Category 5e or above  
UTP/STP cable. The SFP slots are for connecting to the network segment  
with single or multi-mode fiber. The small form-factor pluggable (SFP) is a  
compact optical transceiver used in optical communications.  
Note  
When an SFP module is inserted, the associated copper port is  
disabled.  
10  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Cabling  
Twisted-pair segment can be either unshielded twisted pair (UTP) or  
shielded twisted pair (STP) cabling. The cable between the link partner  
(switch, hub, workstation, etc.) and the converter must be less than 100  
meters (328 ft.) long and comply with the IEEE 802.3ab 1000Base-T  
standard for Category 5e or above.  
Single-mode fiber links must use 9/125μm single-mode fiber cable.  
Multi-mode fiber links must use 50/125 or 62.5/125μm multi-mode fiber  
cable. The small form-factor pluggable (SFP) is a compact optical  
transceiver  
To connect the transceiver and LC cable, follow the steps shown below:  
First, insert the transceiver into the SFP module. The triangle mark identifies  
bottom of the module.  
Transceiver to the SFP module  
Manual Documentation Number: EIR618-2SFP-T_5107m  
11  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ensure the module is aligned correctly and then slide the module into the  
SFP slot until a click is heard.  
Transceiver Inserted  
Insert the fiber cable into the transceiver.  
LC connector to the transceiver  
To remove the fiber cable from the transceiver, follow the steps shown  
below:  
12  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Press the upper side of the LC connector from the transceiver and pull it out  
to release.  
Remove LC connector  
Push down the metal loop and pull the transceiver out by the plastic part.  
Pull out from the SFP module  
Manual Documentation Number: EIR618-2SFP-T_5107m  
13  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring the Power Inputs  
Please follow the steps below to insert the power wire.  
1. Insert the positive and negative leads into the V+ and V- contacts on the  
terminal block connector.  
2. To tighten the wire-clamp screws.  
14  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring the Fault Alarm Contact  
The fault alarm contact is in the middle of terminal block connector.  
Note  
Use 12 to 24 AWG wire.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
15  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Installation  
DIN-Rail Mounting  
Rear Panel of  
the switch  
DIN-Rail  
16  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. First, insert the top of the DIN-Rail clip into the track.  
2. Then, lightly push into the track.  
3. Ensure the DIN-Rail clip is tightly secured to the track.  
4. To remove the industrial switch from the track, reverse steps above.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
17  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Panel Mounting  
Follow the steps as below to mount the industrial switch with wall mount plate.  
1. Remove the DIN-Rail from the industrial switch.  
2. Place the panel mount plate on the rear panel.  
3. Use the screws to attach the panel mount.  
4. Use the hook holes at the corners of the plate to mount the switch to the.  
To remove the wall mount plate, reverse steps above.  
18  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Installation  
Installation Steps  
1. Unpack the Industrial switch.  
2. Ensure the DIN-Rail is tightly screwed to the Industrial switch. If not,  
refer to DIN-Rail Mounting section for DIN-Rail installation. To panel  
mount the Industrial switch, refer to Panel Mounting section.  
3. Apply power to the switch (refer to the Wiring the Power Inputs  
section). The power LED will light.  
4. Connect CAT 5 cables to the Industrial switch’s RJ-45 ports and to the  
network devices  
[NOTE] If the network devices do not support MID/MDIX, a  
crossover cable may be required.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
19  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Network Application  
X-Ring Application  
This switch incorporates the X-Ring Protocol to ensure network reliability  
and system restoration within 300 ms in the event of a connection failure.  
The X-Ring algorithm is similar to the spanning tree protocol (STP)  
algorithm but it has faster recovery time. The following figure below is an  
example of an X-Ring application.  
20  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Coupling Ring Application  
If the network has more than one X-Ring group, the coupling ring function is  
used to connect them and add redundancy. This ensures that transmissions  
between the two ring groups will not fail. The figure below is an example of  
the coupling ring application.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
21  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dual Homing Application  
The Dual Homing function is used to prevent a connection loss between the  
X-Ring group and the upper level/core switch. Assign a port in each X-ring  
group to be the Dual Homing ports The Dual Homing function can only be  
used when the X-Ring function is active. Each X-Ring group can have one  
Dual Homing port. Note: The upper level switches must have RSTP  
enabled.  
[NOTE] In Dual Homing application architecture, the upper level switches  
must enable the Rapid Spanning Tree protocol.  
22  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Console Management  
Connecting to the Console Port  
Attach the DB9 end to a PC or terminal and the RJ-45 end to the console  
port on the switch. The PC must have support a terminal emulation  
program.  
Pin Assignment  
DB9 Connector RJ-45 Connector  
NC  
2
1
2
3
4
5
6
7
8
Orange/White  
Orange  
3
Green/White  
Blue  
NC  
5
Blue/White  
Green  
NC  
NC  
NC  
Brown/White  
Brown  
Manual Documentation Number: EIR618-2SFP-T_5107m  
23  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Login in the Console Interface  
When the connection between Switch and PC is ready, turn on the PC, run  
a terminal emulation program or Hyper Terminal, and configure the  
following communication parameters:  
Baud Rate: 9600 bps  
Data Bits: 8  
Parity: none  
Stop Bit: 1  
Flow control: None  
The settings of communication parameters  
After entering the parameter, click ‘OK’. When the blank screen shows up,  
press Enter on the PC keyboard. A login screen will be displayed. Enter  
root’ for the User name and Password.  
24  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Console login interface  
CLI Management  
After you login to the system, you will see a command prompt. To enter CLI  
management interface, type ‘enable’ and press enter.  
CLI command interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
25  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Commands Level  
Access  
Exit  
Modes  
Prompt  
About This Mode  
Method  
Method  
The user commands  
available at the user  
level are a subset of  
those available at the  
privileged level.  
Begin a  
Enter  
User EXEC  
session with  
your switch.  
switch>  
logout or  
quit.  
Use this mode to  
• Perform basic tests.  
• Display system  
information.  
The privileged  
Enter the  
command is the  
enable  
Enter  
advanced mode.  
Use this mode to  
• Display advanced  
function status  
Privileged  
EXEC  
command  
while in User  
EXEC mode.  
switch#  
disable to  
exit.  
• Save configuration  
Enter the  
To exit to  
privileged  
EXEC  
Use this mode to  
configure those  
configure  
command  
while in  
Global  
switch  
parameters that are  
Configuration  
(config)#  
mode, enter going to be applied to  
privileged  
EXEC mode.  
Enter the vlan  
database  
command  
while in  
exit or end  
your switch.  
To exit to  
Use this mode to  
configure  
VLAN  
switch  
(vlan)#  
user EXEC  
database  
mode, enter VLAN-specific  
privileged  
EXEC mode.  
exit.  
parameters.  
Interface  
Enter the  
switch  
To exit to  
Use this mode to  
configuration  
interface of  
(config-if)# global  
configure parameters  
26  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fast Ethernet  
command  
(with a  
configuratio  
n mode,  
for the switch and  
Ethernet ports.  
enter exit.  
To exit to  
privileged  
EXEC  
specific  
interface)  
while in global  
configuration  
mode  
mode, enter  
exit or end.  
Commands Set List  
User EXEC  
E
P
G
V
I
Privileged EXEC  
Global configuration  
VLAN database  
Interface configuration  
System Commands Set  
Commands  
show config  
Level Description  
Example  
E
P
P
Show switch  
switch>show config  
configuration  
Show console  
information  
show terminal  
write memory  
switch#show terminal  
switch#write memory  
Save user  
configuration into  
permanent memory  
(flash rom)  
system name  
G
G
G
Configure system  
name  
switch(config)#system name xxx  
[System Name]  
system location  
[System Location]  
system description  
[System Description]  
Set switch system  
location string  
Set switch system  
description string  
switch(config)#system location  
xxx  
switch(config)#system  
description xxx  
Manual Documentation Number: EIR618-2SFP-T_5107m  
27  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
system contact  
[System Contact]  
show system-info  
G
E
Set switch system  
switch(config)#system contact  
contact window string xxx  
Show system  
information  
switch>show system-info  
ip address  
[Ip-address]  
[Subnet-mask]  
[Gateway]  
ip dhcp  
G
Configure the IP  
address of switch  
switch(config)#ip address  
192.168.1.1 255.255.255.0  
192.168.1.254  
G
P
Enable DHCP client  
function of switch  
switch(config)#ip dhcp  
show ip  
no ip dhcp  
reload  
Show IP information of switch#show ip  
switch  
G
G
Disable DHCP client switch(config)#no ip dhcp  
function of switch  
Halt and perform a cold  
restart  
switch(config)#reload  
default  
G
G
Restore to default  
Changes a login  
username.  
switch(config)#default  
switch(config)#admin username  
xxxxxx  
admin username  
[Username]  
(maximum 10 words)  
admin password  
[Password]  
G
P
Specifies a password switch(config)#admin password  
(maximum 10 words) xxxxxx  
show admin  
Show administrator  
information  
switch#show admin  
dhcpserver enable  
Dhcpserver disable  
dhcpserver lowip  
[Low IP]  
G
G
G
Enable DHCP Server switch(config)#dhcpserver enable  
Disable DHCP Server switch(config)#no dhcpserver  
Configure low IP  
address for IP pool  
Configure high IP  
address for IP pool  
Configure subnet  
switch(config)#dhcpserver lowip  
192.168.1.100  
dhcpserver highip  
[High IP]  
G
G
G
G
switch(config)#dhcpserver highip  
192.168.1.200  
dhcpserver subnetmask  
[Subnet mask]  
switch(config)#dhcpserver  
mask for DHCP clients subnetmask 255.255.255.0  
Configure gateway for switch(config)#dhcpserver  
dhcpserver gateway  
[Gateway]  
DHCP clients  
gateway 192.168.1.254  
dhcpserver dnsip  
Configure DNS IP for switch(config)#dhcpserver dnsip  
28  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[DNS IP]  
DHCP clients  
Configure lease time switch(config)#dhcpserver  
(in hour)  
leasetime 1  
Set static IP for DHCP switch(config)#interface  
192.168.1.1  
dhcpserver leasetime  
[Hours]  
G
I
dhcpserver ipbinding  
[IP address]  
clients by port  
fastEthernet 2  
switch(config)#dhcpserver  
ipbinding 192.168.1.1  
show dhcpserver  
configuration  
P
P
P
Show configuration of switch#show dhcpserver  
DHCP server  
configuration  
show dhcpserver clients  
Show client entries of switch#show dhcpserver clients  
DHCP server  
show dhcpserver  
ip-binding  
Show IP-Binding  
switch#show dhcpserver  
information of DHCP ip-binding  
server  
no dhcpserver  
security enable  
security http  
G
G
G
G
G
Disable DHCP server switch(config)#no dhcpserver  
function  
Enable IP security  
function  
switch(config)#security enable  
Enable IP security of switch(config)#security http  
HTTP server  
security telnet  
Enable IP security of switch(config)#security telnet  
telnet server  
security ip  
Set the IP security list switch(config)#security ip 1  
192.168.1.55  
[Index(1..10)] [IP  
Address]  
show security  
P
G
G
G
Show the information switch#show security  
of IP security  
no security  
Disable IP security  
function  
switch(config)#no security  
no security http  
no security telnet  
Disable IP security of switch(config)#no security http  
HTTP server  
Disable IP security of switch(config)#no security telnet  
telnet server  
Manual Documentation Number: EIR618-2SFP-T_5107m  
29  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Commands Set  
Commands  
interface fastEthernet  
[Portid]  
Level Description  
Example  
G
Choose the port for  
switch(config)#interface  
fastEthernet 2  
modification.  
duplex  
I
Use the duplex  
configuration  
switch(config)#interface  
fastEthernet 2  
[full | half]  
command to specify  
the duplex mode of  
operation for Fast  
Ethernet.  
switch(config-if)#duplex full  
speed  
I
Use the speed  
switch(config)#interface  
fastEthernet 2  
[10|100|1000|auto]  
configuration  
command to specify  
the speed mode of  
operation for Fast  
Ethernet., the speed  
can’t be set to 1000 if  
the port isn’t a giga  
port..  
switch(config-if)#speed 100  
no flowcontrol  
security enable  
I
I
Disable flow control of switch(config-if)#no flowcontrol  
interface  
Enable security of  
interface  
switch(config)#interface  
fastEthernet 2  
switch(config-if)#security enable  
switch(config)#interface  
fastEthernet 2  
no security  
I
I
Disable security of  
interface  
switch(config-if)#no security  
bandwidth type all  
Set interface ingress switch(config)#interface  
limit frame type to  
“accept all frame”  
fastEthernet 2  
switch(config-if)#bandwidth type  
all  
bandwidth type  
I
Set interface ingress switch(config)#interface  
broadcast-multicast-floo  
ded-unicast  
limit frame type to  
“accept broadcast,  
fastEthernet 2  
switch(config-if)#bandwidth type  
30  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
multicast, and flooded broadcast-multicast-flooded-uni  
unicast frame”  
cast  
Set interface ingress switch(config)#interface  
limit frame type to  
fastEthernet 2  
“accept broadcast and switch(config-if)#bandwidth type  
multicast frame”  
broadcast-multicast  
Set interface ingress switch(config)#interface  
limit frame type to  
fastEthernet 2  
“only accept broadcast switch(config-if)#bandwidth type  
bandwidth type  
I
I
I
broadcast-multicast  
bandwidth type  
broadcast-only  
frame”  
broadcast-only  
bandwidth in  
[Value]  
Set interface input  
bandwidth. Rate  
Range is from 100  
kbps to 102400 kbps  
or to 256000 kbps for  
giga ports,  
switch(config)#interface  
fastEthernet 2  
switch(config-if)#bandwidth in 100  
and zero means no  
limit.  
bandwidth out  
[Value]  
Set interface output  
bandwidth. Rate  
Range is from 100  
switch(config)#interface  
fastEthernet 2  
switch(config-if)#bandwidth out  
kbps to 102400 kbps 100  
or to 256000 kbps for  
giga ports,  
and zero means no  
limit.  
show bandwidth  
I
I
Show interfaces  
switch(config)#interface  
bandwidth control  
fastEthernet 2  
switch(config-if)#show bandwidth  
state  
Use the state interface switch(config)#interface  
configuration  
fastEthernet 2  
[Enable | Disable]  
command to specify (config-if)#state Disable  
the state mode of  
Manual Documentation Number: EIR618-2SFP-T_5107m  
31  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
operation for Ethernet  
ports. Use the disable  
form of this command  
to disable the port.  
show interface  
show interface  
configuration  
I
switch(config)#interface  
fastEthernet 2  
configuration status  
switch(config-if)#show interface  
configuration  
show interface status  
I
I
show interface actual switch(config)#interface  
status  
fastEthernet 2  
(config-if)#show interface status  
show interface  
accounting  
show interface statistic switch(config)#interface  
counter  
fastEthernet 2  
(config-if)#show interface  
accounting  
no accounting  
I
Clear interface  
switch(config)#interface  
accounting information fastEthernet 2  
switch(config-if)#no accounting  
Trunk Commands Set  
Commands  
Level Description  
Example  
aggregator priority  
[1~65535]  
G
Set port group system switch(config)#aggregator priority  
priority  
22  
aggregator activityport  
[Group ID]  
G
Set activity port  
switch(config)#aggregator  
activityport 2  
[Port Numbers]  
aggregator group  
[GroupID] [Port-list]  
lacp  
G
Assign a trunk group switch(config)#aggregator group  
with LACP active.  
[GroupID] :1~3  
1 1-4 lacp workp 2  
or  
workp  
[Port-list]:Member port switch(config)#aggregator group  
[Workport]  
list, This parameter  
could be a port  
2 1,4,3 lacp workp 3  
range(ex.1-4) or a port  
list separate by a  
32  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
comma(ex.2, 3, 6)  
[Workport]: The  
amount of work ports,  
this value could not be  
less than zero or be  
large than the amount  
of member ports.  
aggregator group  
[GroupID] [Port-list]  
nolacp  
G
Assign a static trunk switch(config)#aggregator group  
group.  
1 2-4 nolacp  
[GroupID] :1~3  
or  
[Port-list]:Member port switch(config)#aggregator group  
list, This parameter  
could be a port  
1 3,1,2 nolacp  
range(ex.1-4) or a port  
list separate by a  
comma(ex.2, 3, 6)  
show aggregator  
P
Show the information switch#show aggregator 1  
of trunk group  
or  
switch#show aggregator 2  
or  
switch#show aggregator 3  
switch(config)#no aggreator lacp  
no aggregator lacp  
[GroupID]  
G
G
Disable the LACP  
function of trunk group 1  
no aggregator group  
[GroupID]  
Remove a trunk group switch(config)#no aggreator  
group 2  
VLAN Commands Set  
Commands  
Level Description  
Example  
vlan database  
P
Enter VLAN configure switch#vlan database  
mode  
Vlanmode  
V
To set switch VLAN  
mode.  
switch(vlan)#vlanmode portbase  
[portbase| 802.1q |  
gvrp]  
or  
switch(vlan)#vlanmode 802.1q  
Manual Documentation Number: EIR618-2SFP-T_5107m  
33  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
or  
switch(vlan)#vlanmode gvrp  
Switch(vlan)#no vlan  
no vlan  
V
No VLAN  
Ported based VLAN configuration  
vlan port-based  
grpname  
V
Add new port based switch(vlan)#vlan port-based  
VALN  
grpname test grpid 2 port 2-4  
or  
[Group Name]  
grpid  
switch(vlan)#vlan port-based  
grpname test grpid 2 port 2,3,4  
[GroupID]  
port  
[PortNumbers]  
show vlan [GroupID]  
or  
show vlan  
no vlan group  
[GroupID]  
V
V
Show VLAN  
information  
switch(vlan)#show vlan 23  
Delete port base group switch(vlan)#no vlan group 2  
ID  
IEEE 802.1Q VLAN  
vlan 8021q name  
[GroupName]  
vid  
V
V
V
V
Change the name of switch(vlan)#vlan 8021q name  
VLAN group, if the  
group didn’t exist, this  
command can’t be  
applied.  
test vid 22  
[VID]  
vlan 8021q port  
[PortNumber]  
access-link untag  
[UntaggedVID]  
Assign an access link switch(vlan)#vlan 8021q port 3  
for VLAN by port, if the access-link untag 33  
port belongs to a trunk  
group, this command  
can’t be applied.  
vlan 8021q port  
[PortNumber]  
trunk-link tag  
Assign a trunk link for switch(vlan)#vlan 8021q port 3  
VLAN by port, if the  
trunk-link tag 2,3,6,99  
[TaggedVID List]  
port belongs to a trunk or  
group, this command switch(vlan)#vlan 8021q port 3  
can’t be applied.  
Assign a hybrid link for switch(vlan)#vlan 8021q port 3  
VLAN by port; if the  
hybrid-link untag 4 tag 3,6,8  
port belongs to a trunk or  
trunk-link tag 3-20  
vlan 8021q port  
[PortNumber]  
hybrid-link untag  
[UntaggedVID]  
tag  
34  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[TaggedVID List]  
group, this command switch(vlan)#vlan 8021q port 3  
can’t be applied.  
hybrid-link untag 5 tag 6-8  
Assign a access link switch(vlan)#vlan 8021q trunk 3  
vlan 8021q trunk  
[PortNumber]  
access-link untag  
[UntaggedVID]  
V
V
for VLAN by trunk  
group  
access-link untag 33  
vlan 8021q trunk  
[PortNumber]  
trunk-link tag  
Assign a trunk link for switch(vlan)#vlan 8021q trunk 3  
VLAN by trunk group trunk-link tag 2,3,6,99  
or  
[TaggedVID List]  
switch(vlan)#vlan 8021q trunk 3  
trunk-link tag 3-20  
vlan 8021q trunk  
[PortNumber]  
hybrid-link untag  
[UntaggedVID]  
tag  
V
Assign a hybrid link for switch(vlan)#vlan 8021q trunk 3  
VLAN by trunk group hybrid-link untag 4 tag 3,6,8  
or  
switch(vlan)#vlan 8021q trunk 3  
hybrid-link untag 5 tag 6-8  
[TaggedVID List]  
show vlan [GroupID]  
or  
show vlan  
no vlan group  
[GroupID]  
V
Show VLAN  
information  
switch(vlan)#show vlan 23  
V
Delete port base group switch(vlan)#no vlan group 2  
ID  
Spanning Tree Commands Set  
Commands  
Level Description  
Example  
Enable spanning tree switch(config)#spanning-tree  
enable  
spanning-tree enable  
G
G
G
spanning-tree priority  
[0~61440]  
Configure spanning  
switch(config)#spanning-tree  
tree priority parameter priority 32767  
spanning-tree max-age  
[seconds]  
Use the spanning-tree switch(config)#spanning-tree  
max-age global  
max-age 15  
configuration  
command to change  
the interval between  
messages the  
spanning tree receives  
Manual Documentation Number: EIR618-2SFP-T_5107m  
35  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
from the root switch. If  
a switch does not  
receive a bridge  
protocol data unit  
(BPDU) message from  
the root switch within  
this interval, it  
recomputed the  
Spanning Tree  
Protocol (STP)  
topology.  
spanning-tree  
G
Use the spanning-tree switch(config)#spanning-tree  
hello-time [seconds]  
hello-time global  
hello-time 3  
configuration  
command to specify  
the interval between  
hello bridge protocol  
data units (BPDUs).  
spanning-tree  
G
Use the spanning-tree switch(config)#spanning-tree  
forward-time [seconds]  
forward-time global  
configuration  
forward-time 20  
command to set the  
forwarding-time for the  
specified  
spanning-tree  
instances. The  
forwarding time  
determines how long  
each of the listening  
and learning states  
last before the port  
begins forwarding.  
stp-path-cost  
[1~200000000]  
I
Use the spanning-tree switch(config)#interface  
cost interface  
fastEthernet 2  
36  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
configuration  
switch(config-if)#stp-path-cost 20  
command to set the  
path cost for Spanning  
Tree  
Protocol (STP)  
calculations. In the  
event of a loop,  
spanning tree  
considers the path  
cost when selecting  
an interface to place  
into the forwarding  
state.  
stp-path-priority  
[Port Priority]  
I
Use the spanning-tree switch(config)#interface  
port-priority interface fastEthernet 2  
configuration  
switch(config-if)#stp-path-priority  
command to configure 128  
a port priority that  
is used when two  
switches tie for  
position as the root  
switch.  
stp-admin-p2p  
I
I
I
Admin P2P of STP  
priority on this  
interface.  
switch(config)#interface  
[Auto|True|False]  
fastEthernet 2  
switch(config-if)#stp-admin-p2p  
Auto  
stp-admin-edge  
[True|False]  
Admin Edge of STP  
priority on this  
interface.  
switch(config)#interface  
fastEthernet 2  
switch(config-if)#stp-admin-edge  
True  
stp-admin-non-stp  
[True|False]  
Admin NonSTP of STP switch(config)#interface  
priority on this  
interface.  
fastEthernet 2  
switch(config-if)#stp-admin-non-s  
Manual Documentation Number: EIR618-2SFP-T_5107m  
37  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
tp False  
Displays a summary of switch>show spanning-tree  
the spanning-tree  
show spanning-tree  
E
states.  
no spanning-tree  
G
Disable spanning-tree. switch(config)#no spanning-tree  
QOS Commands Set  
Commands  
Level Description  
Example  
qos policy  
G
Select QOS policy  
scheduling  
switch(config)#qos policy  
weighted-fair  
[weighted-fair|strict]  
qos prioritytype  
G
Setting of QOS priority switch(config)#qos prioritytype  
[port-based|cos-only|tos  
-only|cos-first|tos-first]  
type  
qos priority portbased  
[Port]  
G
Configure Port-based switch(config)#qos priority  
Priority  
portbased 1 low  
[lowest|low|middle|high]  
qos priority cos  
[Priority][lowest|low|mid  
dle|high]  
G
G
Configure COS Priority switch(config)#qos priority cos 0  
middle  
Configure TOS Priority  
switch(config)#  
qos priority tos 3  
qos priority tos  
high  
[Priority][lowest|low|mid  
dle|high]  
show qos  
P
Displays the  
Switch#  
show qos  
information of QoS  
configuration  
no qos  
G
Disable QoS function  
switch(config)#  
no qos  
IGMP Commands Set  
Commands  
igmp enable  
Level Description  
Example  
G
G
G
Enable IGMP  
switch(config)#igmp enable  
snooping function  
Set IGMP query to  
auto mode  
Igmp-query auto  
Igmp-query force  
38  
switch(config)#Igmp-query auto  
switch(config)#Igmp-query force  
Set IGMP query to  
force mode  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
show igmp  
P
P
Displays the details of switch#show igmp configuration  
configuration  
an IGMP  
configuration.  
show igmp multi  
Displays the details of switch#show igmp multi  
an IGMP snooping  
entries.  
no igmp  
G
G
Disable IGMP  
switch(config)#no igmp  
snooping function  
no igmp-query  
Disable IGMP query switch#no igmp-query  
Mac / Filter Table Commands Set  
Commands  
mac-address-table static  
hwaddr  
Level Description  
Example  
I
Configure MAC  
address table of  
interface (static).  
switch(config)#interface  
fastEthernet 2  
[MAC]  
switch(config-if)#mac-address-tab  
le static hwaddr 000012345678  
switch(config)#mac-address-table  
filter hwaddr 000012348678  
mac-address-table filter  
hwaddr  
G
Configure MAC  
address table(filter)  
[MAC]  
show mac-address-table  
P
P
P
I
Show all MAC address switch#show mac-address-table  
table  
show mac-address-table  
static  
Show static MAC  
address table  
switch#show mac-address-table  
static  
show mac-address-table  
filter  
Show filter MAC  
address table.  
switch#show mac-address-table  
filter  
no mac-address-table  
static hwaddr  
[MAC]  
Remove an entry of  
switch(config)#interface  
MAC address table of fastEthernet 2  
interface (static)  
switch(config-if)#no  
mac-address-table static hwaddr  
000012345678  
no mac-address-table  
filter hwaddr  
[MAC]  
G
Remove an entry of  
MAC address table  
(filter)  
switch(config)#no  
mac-address-table filter hwaddr  
000012348678  
Manual Documentation Number: EIR618-2SFP-T_5107m  
39  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
no mac-address-table  
G
Remove dynamic entry switch(config)#no  
of MAC address table mac-address-table  
SNMP Commands Set  
Commands  
Level Description  
Example  
snmp system-name  
[System Name]  
snmp system-location  
[System Location]  
snmp system-contact  
[System Contact]  
snmp agent-mode  
[v1v2c|v3|v1v2cv3]  
snmp  
G
Set SNMP agent  
system name  
switch(config)#snmp  
system-name l2switch  
switch(config)#snmp  
system-location lab  
switch(config)#snmp  
system-contact where  
G
G
G
G
Set SNMP agent  
system location  
Set SNMP agent  
system contact  
Select the agent mode switch(config)#snmp agent-mode  
of SNMP  
v1v2cv3  
Add SNMP community switch(config)#snmp  
community-strings  
[Community]  
string.  
community-strings public right  
rw  
right  
[RO/RW]  
snmp-server host  
[IP address]  
G
Configure SNMP  
switch(config)#snmp-server host  
server host information 192.168.1.50 community public  
and community string trap-version v1  
(remove)  
community  
[Community-string]  
trap-version  
Switch(config)#  
[v1|v2c]  
no snmp-server host  
192.168.1.50  
snmpv3 context-name  
[Context Name ]  
snmpv3 user  
[User Name]  
G
G
Configure the context switch(config)#snmpv3  
name  
context-name Test  
Configure the  
userprofile for  
SNMPV3 agent.  
Privacy password  
could be empty.  
switch(config)#snmpv3 user  
test01 group G1 password  
AuthPW PrivPW  
group  
[Group Name]  
password  
[Authentication  
Password] [Privacy  
40  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Password]  
snmpv3 access  
context-name [Context  
Name ]  
G
Configure the access switch(config)#snmpv3 access  
table of SNMPV3  
agent  
context-name Test group G1  
security-level AuthPriv  
group  
match-rule Exact views V1 V1 V1  
[Group Name ]  
security-level  
[NoAuthNoPriv|AuthNoP  
riv|AuthPriv]  
match-rule  
[Exact|Prifix]  
views  
[Read View Name] [Write  
View Name] [Notify View  
Name]  
snmpv3 mibview view  
[View Name]  
type  
G
Configure the mibview switch(config)#snmpv3 mibview  
table of SNMPV3  
agent  
view V1 type Excluded sub-oid  
1.3.6.1  
[Excluded|Included]  
sub-oid  
[OID]  
show snmp  
P
Show SNMP  
configuration  
switch#show snmp  
no snmp  
G
Remove the specified switch(config)#no snmp  
community-strings  
[Community]  
community.  
community-strings public  
no snmp-server host  
[Host-address]  
no snmpv3 user  
[User Name]  
G
G
G
Remove the SNMP  
server host.  
switch(config)#no snmp-server  
192.168.1.50  
Remove specified user switch(config)#no snmpv3 user  
of SNMPv3 agent.  
Remove specified  
access table of  
Test  
no snmpv3 access  
context-name [Context  
Name ]  
switch(config)#no snmpv3 access  
context-name Test group G1  
security-level AuthPr  
SNMPv3 agent.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
41  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
group  
iv match-rule Exact views V1 V1  
V1  
[Group Name ]  
security-level  
[NoAuthNoPriv|AuthNoP  
riv|AuthPriv]  
match-rule  
[Exact|Prifix]  
views  
[Read View Name] [Write  
View Name] [Notify View  
Name]  
no snmpv3 mibview  
view  
G
Remove specified  
mibview table of  
SNMPV3 agent.  
switch(config)#no snmpv3  
mibview view V1 type Excluded  
sub-oid 1.3.6.1  
[View Name]  
type  
[Excluded|Included]  
sub-oid  
[OID]  
Port Mirroring Commands Set  
Commands  
monitor  
Level Description  
Example  
I
Configure source port switch(config)#interface  
[RX|TX|Both]  
of monitor function  
fastEthernet 2  
switch(config-if)#monitor RX  
switch(config)#monitor rx 2  
monitor rx [Port ID]  
monitor tx [Port ID]  
show monitor  
G
G
P
I
Set RX destination  
port of monitor function  
Set TX destination port switch(config)#monitor tx 3  
of monitor function  
Show port monitor  
information  
switch#show monitor  
show monitor  
Show port monitor  
information  
switch(config)#interface  
fastEthernet 2  
switch(config-if)#show monitor  
no monitor  
I
Disable source port of switch(config)#interface  
42  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
monitor function  
fastEthernet 2  
switch(config-if)#no monitor  
802.1x Commands Set  
Commands  
Level Description  
Example  
8021x enable  
G
Use the 802.1x global switch(config)# 8021x enable  
configuration  
command to enable  
802.1x protocols.  
8021x system radiusip  
[IP address]  
G
Use the 802.1x system switch(config)# 8021x system  
radius IP global  
radiusip 192.168.1.1  
configuration  
command to change  
the radius server IP.  
8021x system serverport  
[port ID]  
G
G
G
G
Use the 802.1x system switch(config)# 8021x system  
server port global  
configuration  
serverport 1815  
command to change  
the radius server port  
8021x system  
accountport  
[port ID]  
Use the 802.1x system switch(config)# 8021x system  
account port global  
configuration  
accountport 1816  
command to change  
the accounting port  
8021x system sharekey  
[ID]  
Use the 802.1x system switch(config)# 8021x system  
share key global  
configuration  
sharekey 123456  
command to change  
the shared key value.  
8021x system nasid  
[words]  
Use the 802.1x system switch(config)# 8021x system  
nasid global  
nasid test1  
configuration  
command to change  
Manual Documentation Number: EIR618-2SFP-T_5107m  
43  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
the NAS ID  
8021x misc quietperiod  
[sec.]  
G
Use the 802.1x misc switch(config)# 8021x misc  
quiet period global  
configuration  
quietperiod 10  
command to specify  
the quiet period value  
of the switch.  
8021x misc txperiod  
[sec.]  
G
G
G
G
G
I
Use the 802.1x misc switch(config)# 8021x misc  
TX period global  
configuration  
txperiod 5  
command to set the  
TX period.  
8021x misc  
Use the 802.1x misc switch(config)# 8021x misc  
supportimeout [sec.]  
supp timeout global  
configuration  
supportimeout 20  
command to set the  
supplicant timeout.  
8021x misc  
Use the 802.1x misc switch(config)#8021x misc  
server timeout global servertimeout 20  
configuration  
servertimeout [sec.]  
command to set the  
server timeout.  
8021x misc maxrequest  
[number]  
Use the 802.1x misc switch(config)# 8021x misc  
max request global  
configuration  
maxrequest 3  
command to set the  
MAX requests.  
8021x misc  
Use the 802.1x misc switch(config)# 8021x misc  
reauthperiod [sec.]  
reauth period global  
configuration  
reauthperiod 3000  
command to set the  
reauth period.  
8021x portstate  
Use the 802.1x port  
state interface  
switch(config)#interface  
[disable | reject | accept |  
fastethernet 3  
44  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
authorize]  
configuration  
switch(config-if)#8021x portstate  
command to set the  
state of the selected  
port.  
accept  
show 8021x  
E
Displays a summary of switch>show 8021x  
the 802.1x properties  
and also the port  
sates.  
no 8021x  
G
Disable 802.1x  
function  
switch(config)#no 8021x  
TFTP Commands Set  
Commands  
backup  
Level Description  
Defaults Example  
switch(config)#backup  
flash:backup_cfg  
G
G
G
Save configuration to  
flash:backup_cfg  
TFTP and need to  
specify the IP of TFTP  
server and the file name  
of image.  
restore flash:restore_cfg  
Get configuration from switch(config)#restore  
TFTP server and need to flash:restore_cfg  
specify the IP of TFTP  
server and the file name  
of image.  
upgrade  
Upgrade firmware by  
TFTP and need to  
specify the IP of TFTP  
server and the file name  
of image.  
switch(config)#upgrade  
flash:upgrade_fw  
lash:upgrade_fw  
SystemLog, SMTP and Event Commands Set  
Commands  
systemlog ip  
[IP address]  
Level Description  
Example  
G
Set System log server switch(config)# systemlog ip  
IP address.  
192.168.1.100  
Manual Documentation Number: EIR618-2SFP-T_5107m  
45  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
systemlog mode  
[client|server|both]  
show systemlog  
show systemlog  
G
Specified the log mode switch(config)# systemlog mode  
both  
E
P
Displays system log. Switch>show systemlog  
Show system log client switch#show systemlog  
& server information  
no systemlog  
G
Disable systemlog  
functon  
switch(config)#no systemlog  
smtp enable  
G
G
Enable SMTP function switch(config)#smtp enable  
smtp serverip  
[IP address]  
Configure SMTP  
server IP  
switch(config)#smtp serverip  
192.168.1.5  
smtp authentication  
G
G
G
Enable SMTP  
authentication  
Configure  
switch(config)#smtp  
authentication  
smtp account  
[account]  
switch(config)#smtp account  
authentication account John  
smtp password  
[password]  
Configure  
switch(config)#smtp password  
1234  
authentication  
password  
smtp rcptemail  
[Index] [Email address]  
show smtp  
G
P
Configure Rcpt e-mail switch(config)#smtp rcptemail 1  
Address  
Show the information switch#show smtp  
of SMTP  
no smtp  
G
G
Disable SMTP function switch(config)#no smtp  
event device-cold-start  
[Systemlog|SMTP|Both]  
event  
Set cold start event  
type  
switch(config)#event  
device-cold-start both  
switch(config)#event  
G
G
I
Set Authentication  
failure event type  
authentication-failure  
[Systemlog|SMTP|Both]  
event  
authentication-failure both  
Set X-ring topology  
changed event type  
switch(config)#event  
ring-topology-change  
[Systemlog|SMTP|Both]  
event systemlog  
[Link-UP|Link-Down|Bot  
h]  
ring-topology-change both  
Set port event for  
system log  
switch(config)#interface  
fastethernet 3  
switch(config-if)#event systemlog  
both  
46  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
event smtp  
I
Set port event for  
SMTP  
switch(config)#interface  
fastethernet 3  
[Link-UP|Link-Down|Bot  
h]  
switch(config-if)#event smtp both  
show event  
P
Show event selection switch#show event  
no event  
G
Disable cold start  
event type  
switch(config)#no event  
device-cold-start  
no event  
device-cold-start  
G
G
Disable Authentication switch(config)#no event  
authentication-failure  
no event  
failure event typ  
Disable X-ring  
topology changed  
event type  
authentication-failure  
switch(config)#no event  
X-ring-topology-change  
X-ring-topology-change  
no event systemlog  
I
Disable port event for switch(config)#interface  
system log  
fastethernet 3  
switch(config-if)#no event  
systemlog  
no event smpt  
I
Disable port event for switch(config)#interface  
SMTP  
fastethernet 3  
switch(config-if)#no event smtp  
show systemlog  
P
Show system log client switch#show systemlog  
& server information  
SNTP Commands Set  
Commands  
sntp enable  
Level Description  
Example  
G
G
Enable SNTP function switch(config)#sntp enable  
sntp daylight  
Enable daylight saving switch(config)#sntp daylight  
time, if SNTP function  
is inactive, this  
command can’t be  
applied.  
sntp daylight-period  
[Start time] [End time]  
G
Set period of daylight switch(config)# sntp  
saving time, if SNTP daylight-period 20060101-01:01  
function is inactive,  
20060202-01:01  
this command can’t be  
Manual Documentation Number: EIR618-2SFP-T_5107m  
47  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
applied.  
Parameter format:  
[yyyymmdd-hh:mm]  
sntp daylight-offset  
[Minute]  
G
Set offset of daylight switch(config)#sntp  
saving time, if SNTP daylight-offset 3  
function is inactive,  
this command can’t be  
applied.  
sntp ip  
[IP]  
G
G
Set SNTP server IP, if switch(config)#sntp ip 192.169.1.1  
SNTP function is  
inactive, this command  
can’t be applied.  
sntp timezone  
[Timezone]  
Set timezone index,  
use “show sntp  
timzezone” command  
to get more  
switch(config)#sntp timezone 22  
information of index  
number  
show sntp  
P
P
Show SNTP  
switch#show sntp  
information  
show sntp timezone  
Show index number of switch#show sntp timezone  
time zone list  
no sntp  
G
G
Disable SNTP function switch(config)#no sntp  
Disable daylight saving switch(config)#no sntp daylight  
time  
no sntp daylight  
X-ring Commands Set  
Commands  
Level Description  
Example  
Xring enable  
G
Enable X-ring  
switch(config)#Xring enable  
switch(config)#Xring master  
switch(config)#Xring couplering  
switch(config)#Xring dualhoming  
switch(config)#Xring ringport 7 8  
Xring master  
G
G
G
G
Enable ring master  
Enable couple ring  
Enable dual homing  
Configure 1st/2nd  
Ring Port  
Xring couplering  
Xring dualhoming  
Xring ringport  
[1st Ring Port] [2nd Ring  
48  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port]  
Xring couplingport  
[Coupling Port]  
Xring controlport  
[Control Port]  
Xring homingport  
[Dual Homing Port]  
show Xring  
G
G
G
P
Configure Coupling  
Port  
switch(config)#Xring couplingport  
1
Configure Control Port switch(config)#Xring controlport 2  
Configure Dual  
Homing Port  
switch(config)#Xring homingport  
3
Show the information switch#show Xring  
of X - Ring  
no Xring  
G
G
G
Disable X-ring  
switch(config)#no X ring  
switch(config)# no Xring master  
switch(config)# no Xring  
couplering  
no Xring master  
no Xring couplering  
Disable ring master  
Disable couple ring  
no Xring dualhoming  
G
Disable dual homing switch(config)# no Xring  
dualhoming  
Manual Documentation Number: EIR618-2SFP-T_5107m  
49  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web-Based Management  
About Web-based Management  
The switch has an embedded HTML web site residing in flash memory. This  
site offers advanced management features and allows the switch to be  
configured from anywhere on the network.  
The web site is designed for Internet Explorer 6.0 and uses Java Applets to  
reduce bandwidth consumption, enhance access speed, and present an  
intuitive user interface.  
Preparing for Web Management  
Before using web management, install the industrial switch on the network  
and verify that a PC on the local network can connect with the switch  
through the web browser. The default IP Address, Subnet Mask, Username  
and Password is listed below:  
IP Address: 192.168.16.1  
Subnet Mask: 255.255.255.0  
Default Gateway: 192.168.16.254  
User Name: root  
Password: root  
50  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Login  
1. Launch Internet Explorer on the PC  
2. Key in “http:// “+” the IP address of the switch”, and then Press “Enter”.  
3. The login screen will appear  
4. Enter the user name and password. The default user name and  
password are ‘root’  
5. Press Enter‘ or click OK button, and then the home screen of the  
Web-based management appears.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
51  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Information  
System Name: A name (64 bytes max) can be assigned to the switch.  
System Description: Displays the description of switch. Read only  
cannot be modified  
System Location: A physical location (64 bytes max) can be assigned  
to the switch.  
System Contact: Enter the name of contact person or organization  
Firmware Version: Displays the switch’s firmware version  
Kernel Version: Displays the kernel software version  
MAC Address: Displays the unique hardware address assigned by  
manufacturer (default)  
Apply  
Click  
.
System information interface  
52  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP Configuration  
Configure the IP Settings and DHCP client function  
DHCP Client: Used to enable or disable the DHCP client function.  
When enabled, the switch’s IP address is assigned by the network  
DHCP server. The default IP address will be replace by the DHCP  
server assigned IP address. After clicking the ‘Apply’ button, a popup  
dialog will indicate that the current IP will be lost and the new IP  
address must be retrieved from the DHCP server.  
IP Address: A static IP Address may be assigned. The default IP is  
192.168.16.1.  
Subnet Mask: Assign the subnet mask of the IP address. This does  
not have to be done if the DHCP client function is enabled.  
Gateway: Assign the network gateway. The default gateway is  
192.168.16.254.  
DNS1: Assign the primary DNS IP address.  
DNS2: Assign the secondary DNS IP address.  
Apply  
Click  
IP configuration interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
53  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Server – System configuration  
The switch can function as a DHCP server.  
DHCP Server: Enable or Disable the DHCP Server function.  
Low IP Address: the dynamic IP assign range. Low IP address is the  
beginning of the dynamic IP assignment range.  
High IP Address: the dynamic IP assign range. High IP address is the  
end of the dynamic IP assignment range.  
Subnet Mask: The subnet mask.  
Gateway: The network gateway.  
DNS: Network Domain Name Server IP Address.  
Lease Time (sec): The time interval at which that system will reset the  
dynamic IP assignment.  
Apply  
Click  
DHCP Server Configuration interface  
DHCP Server – Client Entries  
DHCP Client information is displayed.  
54  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DHCP Client Entries interface  
DHCP Server - Port and IP Bindings  
You can assign a specific IP address that is in the dynamic IP assignment  
range to the specific port. When the device is connected to the port and  
asks for an assignment, the system will assign this IP address.  
Port and IP Bindings interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
55  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP - Update Firmware  
Provides the ability to update the switch’s firmware. Before updating, ensure  
you the TFTP server is ready and the firmware image is on the TFTP server.  
1. TFTP Server IP Address: Enter the TFTP server IP.  
2. Firmware File Name: Enter the name of firmware image.  
Apply  
3. Click  
.
Update Firmware interface  
TFTP – Restore Configuration  
If the EEPROM image is stored on the TFTP server, you can restore it to  
flash memory.  
1. TFTP Server IP Address: Enter the TFTP server IP.  
2. Restore File Name: Enter the restore file name.  
Apply  
3. Click  
.
Restore Configuration interface  
56  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TFTP - Backup Configuration  
You can save current EEPROM image to the TFTP server.  
1. TFTP Server IP Address: Enter the TFTP server IP  
2.  
Enter the file name  
Backup File Name:  
Apply  
3. Click  
.
Backup Configuration interface  
System Event Log – Syslog Configuration  
Configure the system event mode to collect system log.  
1. Syslog Client Mode: Select the system log mode – client only, server  
only, or both.  
2. System Log Server IP Address: Assigned the system log server IP  
Reload  
3. Click  
4. Click  
to refresh the event log.  
Clear  
to clear all current event log.  
Apply  
5. After configuring, Click  
.
Manual Documentation Number: EIR618-2SFP-T_5107m  
57  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Syslog Configuration interface  
System Event Log - SMTP Configuration  
Set up the mail server IP, mail account, account password, and email  
account for receiving event alerts.  
1. Email Alert: enable or disable the email alert function.  
2. SMTP Server IP: set up the mail server IP address.  
3. Sender: Enter the email address, e.g. [email protected], to identify  
where the event log came from.  
4. Authentication: Mark the check box to enable and configure the email  
account and password for authentication.  
5. Mail Account: set up the email account, e.g. johnadmin for the switch.  
It must be an existing email account on the mail server.  
58  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Password: The email account password.  
7. Confirm Password: reconfirm the password.  
8. Rcpt e-mail Address 1 through 6: Enter up to six email addresses to  
receive the event log.  
Apply  
9. Click  
button.  
SMTP Configuration interface  
System Event Log - Event Configuration  
When the selected events occur, the system will generate a log entry and  
email notification message. .  
System event selection: Four selections available – Cold Start, Warm  
Start, SNMP Authentication Failure, and X-ring topology change. Mark  
the checkbox to select the event. When the selected events occur, the  
system will send the logs.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
59  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port event selection: When a port specific event occurs, the system  
will generate a log entry and email notification. Three selections are  
available – Link UP, Link Down, and Link UP & Link Down.  
Event Configuration interface  
60  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fault Relay Alarm  
Power Failure: When the check box is marked, the Fault LED will light  
if the power source fails.  
Port Link Down/Broken: When the check box is marked, the Fault  
LED will light if a port link goes down.  
Fault Relay Alarm interface  
SNTP Configuration  
The SNTP allows you to synchronize switch clocks.  
1. SNTP Client: Enables or disables the SNTP function.  
2. Daylight Saving Time: Enables or disables daylight saving time. When  
this function is enabled, the time period must be entered.  
3. UTC Time zone: Sets the local time zone.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
61  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Local Time Zone  
November Time Zone  
Oscar Time Zone  
Conversion from UTC  
- 1 hour  
Time at 12:00 UTC  
11am  
10 am  
9 am  
-2 hours  
ADT - Atlantic Daylight  
-3 hours  
AST - Atlantic Standard  
EDT - Eastern Daylight  
EST - Eastern Standard  
CDT - Central Daylight  
CST - Central Standard  
MDT - Mountain Daylight  
MST - Mountain  
-4 hours  
-5 hours  
-6 hours  
8 am  
7 am  
6 am  
Standard  
-7 hours  
5 am  
PDT - Pacific Daylight  
PST - Pacific Standard  
ADT - Alaskan Daylight  
-8 hours  
-9 hours  
-10 hours  
-11 hours  
4 am  
3 am  
2 am  
1 am  
ALA - Alaskan Standard  
HAW - Hawaiian  
Standard  
Nome, Alaska  
CET - Central European  
FWT - French Winter  
MET - Middle European  
MEWT - Middle  
+1 hour  
1 pm  
European Winter  
SWT - Swedish Winter  
EET - Eastern European,  
Russia Zone 1  
+2 hours  
+3 hours  
2 pm  
3 pm  
BT - Baghdad, Russia  
Zone 2  
62  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ZP4 - Russia Zone 3  
ZP5 – Russia Zone 4  
ZP6 - Russia Zone 5  
+4 hours  
+5 hours  
+6 hours  
4 pm  
5 pm  
6 pm  
WAST - West Australian  
Standard  
+7 hours  
+8 hours  
+9 hours  
7 pm  
8 pm  
9 pm  
CCT - China Coast,  
USSR Zone 7  
JST - Japan Standard,  
Russia Zone 8  
EAST - East Australian  
Standard GST  
+10 hours  
+12 hours  
10 pm  
Guam Standard, Russia  
Zone 9  
IDLE - International Date  
Line  
NZST - New Zealand  
Standard  
Midnight  
NZT - New Zealand  
4. SNTP Sever URL: Enter the SNTP server IP address.  
5. Daylight Saving Period: Enter the Daylight Saving beginning time and  
Daylight Saving end time.  
6. Daylight Saving Offset (mins): Enter the offset in minutes.  
7. Switch Timer: Displays the current time.  
Apply  
8. Click  
.
Manual Documentation Number: EIR618-2SFP-T_5107m  
63  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SNTP Configuration interface  
IP Security  
IP security function grants 10 specific IP addresses permission to access  
the switch through a web browser or TELNET for management.  
IP Security Mode: When enabled, allows management via TELNET  
and HTTP.  
Enable HTTP Server: Mark the box to grant the specified IP addresses  
web based management permission.  
Enable Telnet Server: Mark the box to grant the specified IP  
addresses TELNET management permission.  
Security IP 1 ~ 10: Enter up to 10 IP addresses.  
Apply  
Click  
[NOTE]  
If the configuration is not saved, it will be lost when the  
switch is powered off.  
64  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IP Security interface  
User Authentication  
Use this function to change the login name and password.  
1. User name: Enter the new user name (The default is ‘root’).  
2. Password: Enter the new password (The default is ‘root’).  
3. Confirm password: Confirm the new password.  
Apply  
4. Click  
User Authentication interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
65  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Statistics  
Provides port status.  
Port: The port number.  
Type: Displays the connection speed.  
Link: Displays link status —‘Up’ or ‘Down’.  
State: Enabled or Disabled.  
Tx Good Packet: Displays the number of good packets transmitted.  
Tx Bad Packet: Displays the number of bad packets transmitted.  
Rx Good Packet: Displays the number of good packets received.  
Rx Bad Packet: Displays the number of bad packets received.  
Tx Abort Packet: Displays the number of aborted transmit packets.  
Packet Collision: Displays the number of packet collisions.  
Packet Dropped: Displays the number of dropped packets.  
Rx Bcast Packet: Displays the number of broadcast packets.  
Displays the number of multicast packets.  
Rx Mcast Packet:  
Clear  
Click  
button to reset the numbers.  
Port Statistics interface  
66  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Control  
Used to configure and view port settings.  
1. Port: Select the port to configure.  
2. State: Enable or disable the port.  
3. Negotiation: Set the negotiation status of the port.  
4. Speed: Set the port link speed.  
5. Duplex: Set the port to full or half-duplex.  
6. Flow Control: Set flow control to Symmetric or Asymmetric in Full  
Duplex mode. The default value is Symmetric.  
7. Security: Set the port security. When ‘On’ is selected, the port will only  
accept a connection from one MAC address.  
Apply  
8. Click  
Manual Documentation Number: EIR618-2SFP-T_5107m  
67  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Control interface  
Port Trunk  
The Link Aggregation Control Protocol (LACP) provides a standardized  
method for exchanging information between Partner Systems on a link. This  
allows their Link Aggregation Control instances to reach an agreement on  
the identity of the Link Aggregation Group, move the link to that Link  
Aggregation Group, and enable its transmission and reception functions in  
an orderly manner. Link aggregation lets you group up to four consecutive  
ports into two dedicated connections. This feature expands bandwidth to a  
device on the network. LACP operation requires full-duplex mode.  
Aggregator setting  
1. System Priority: a value used to identify the active LACP. The switch  
with the lowest value has the highest priority. It is selected as the active  
LACP.  
2.  
There are four trunk groups available. Choose the "  
Group ID:  
Group  
Select  
" and click  
ID  
3. LACP: If enabled, the group is an LACP static trunk group. If disabled,  
the group is local static trunk group. All ports support LACP dynamic  
trunk. If connected to a device that also supports LACP, the LACP  
dynamic trunk group is automatically created.  
4. Work ports: A maximum of four ports can be aggregated at the same  
time. With LACP static trunk group, any excess ports are considered  
standby and can be aggregated if a work port fails. If it is local static  
trunk group, the number of ports must be the same as the group  
member ports.  
Add  
5. Select the ports to add to the trunk group. Click  
button to add  
the port. To remove unwanted ports, select the port and click  
Remove  
button.  
68  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. When LACP enabled, you can configure LACP Active/Passive status  
for each port on State Activity page.  
Apply  
7. Click  
Delete  
8. Use  
to delete Trunk Group.  
Port Trunk—Aggregator setting interface (four ports are added to the left field with LACP  
enabled)  
Manual Documentation Number: EIR618-2SFP-T_5107m  
69  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Aggregator Information  
Displays static trunk group information.  
Port Trunk—Aggregator setting interface (two ports are added to the left field with LACP  
disable)  
Port Trunk – Aggregator Information interface  
State Activity  
After setting up the LACP aggregator, port state activity can be configured.  
Apply  
Mark the port and click  
. The port state activity will change to Active  
or Passive depending on its previous state.  
Active: The port automatically sends LACP protocol packets.  
Passive: The port responds only if it receives LACP protocol packets  
from the opposite device.  
70  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
[NOTE]  
1. A link having either two active LACP ports or one  
active port can perform dynamic LACP trunk.  
2. A link, which has two passive LACP ports, will not  
perform dynamic LACP trunk because both ports are  
waiting for an LACP protocol packet from the opposite  
device.  
Port Trunk – State Activity interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
71  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Port Mirroring  
Port mirroring is a method to monitor traffic in switched networks. Traffic  
flowing through the indicated ports can be monitored by a specified port.  
Port Trunk – Port Mirroring interface  
Destination Port: Only one port can be selected as the destination  
(mirror) port for monitoring both RX and TX traffic from the source port.  
Two ports may be configured to monitor RX and TX traffic separately. A  
LAN analyzer can be connected to the mirror port.  
Source Port: Select the ports to monitor. All monitored port traffic will  
be sent to the mirror (destination) port. Multiple source ports by can be  
selected by checking the RX or TX check boxes.  
Apply  
Click  
72  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rate Limiting  
You can set up every port’s frame limitation type and bandwidth rate.  
Rate Limiting interface  
All the ports support port ingress and egress rate control. For example,  
assume port 1 is 10Mbps, users can set its effective egress rate to  
1Mbps, and ingress rate is 500Kbps. The switch performs the ingress  
rate limiting using a packet counter to meet the specified rate  
Enter the port effective ingress rate(The default value is ‘0’)  
Enter the port effective egress rate(The default value is ‘0’)  
Ingress:  
Egress:  
Apply  
Click  
Manual Documentation Number: EIR618-2SFP-T_5107m  
73  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN configuration  
A Virtual LAN (VLAN) can be thought of as a broadcast domain that exists  
within a switch or a defined set of switches. By grouping switch ports into  
VLANs, traffic flooding is limited since devices can only communicate  
directly with devices belonging to the VLAN. Creating a VLAN from a switch  
is the logical equivalent of reconnecting a group of devices to another Layer  
2 switch. However, the network devices retain their same physical  
connection. The switch supports port-based and 802.1Q (tagged-based)  
VLAN. In the default configuration, the VLAN option is disabled  
The switch supports Port-based and 802.1Q (tagged-based) VLAN. The  
default configuration of VLAN operation mode is “Disable”.  
VLAN Configuration interface  
VLAN configuration - Port-based VLAN  
With port-based VLAN, the port is assigned to a VLAN. Therefore, all  
devices attached to a given port should be members of the same VLAN. As  
with other VLAN configurations, the packets forwarded using this method do  
not leak into other VLAN domains on the network. After the port has been  
assigned to a VLAN, devices on the port cannot send to or receive from  
devices in other VLANs without the intervention of another layer 3 device or  
the ability to tag the data packet with a specific PVID  
74  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN – Port Based interface  
Apply  
Pull down the selection item for  
then press  
button  
Port Based  
Add  
Click  
to add a new VLAN group (64 groups maximum).  
VLAN—Port Based Add interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
75  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VLAN—Port Based Edit/Delete interface  
Delete  
Edit  
Use  
Use  
button to delete the VLAN.  
button to modify group name, VLAN ID, or add/remove the  
members of the existing VLAN group.  
[NOTE] If the configuration is not saved, it will be lost when the port is  
powered off.  
76  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
802.1Q VLAN  
Tagged-based VLAN is an IEEE 802.1Q specification, which allows VLANs  
to be created across devices from different venders. IEEE 802.1Q VLAN  
uses a technique to insert a “tag” into the Ethernet frame. The tag contains a  
VLAN Identifier (VID).  
When the 802.1Q VLAN is enabled, all ports on the switch belong to a  
default VLAN (VID 1). The default VLAN cannot be deleted. Up to 64 VLAN  
groups are supported.  
802.1Q Configuration  
1. Enable GVRP Protocol: check the check box to enable GVRP  
protocol.  
2. Select the port to configure.  
3. Link Type: there are three link types.  
Access Link: Single switch only. Allows ports to be grouped by  
setting the same VID.  
Trunk Link: Extended application of Access Link. Allows ports to  
be grouped by setting the same VID on two or more switches.  
Hybrid Link: Both Access Link and Trunk Link.  
4. Untagged VID: assign the untagged frame VID.  
5. Tagged VID: assign the tagged frame VID.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
77  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
802.1Q VLAN interface  
Group Configuration  
Edit the existing VLAN Group.  
Select the VLAN group in the table list.  
Edit  
Click  
button.  
78  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Group Configuration interface  
You can modify the VLAN group name and VLAN ID.  
Group Configuration interface  
Apply  
Click  
button.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
79  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rapid Spanning Tree  
The Rapid Spanning Tree Protocol (RSTP) is an evolution of Spanning Tree  
Protocol (STP). It provides a faster spanning tree convergence after a  
topology change. The switch will auto detect a device that is running STP or  
RSTP protocol.  
RSTP - System Configuration  
Apply  
After modification, click  
¾
¾
RSTP mode: Enable or disable the RSTP.  
Priority (0-61440): a value used to identify the root bridge. The  
bridge with the lowest value has the highest priority and is selected  
as the root. If the value changes, the switch must be rebooted. The  
value must be multiple of 4096.  
¾
¾
¾
Max Age (6-40): The number of seconds a bridge waits without  
receiving Spanning-tree Protocol configuration messages before  
attempting a reconfiguration. Enter a value between 6 through 40  
Hello Time (1-10): The time that controls when, the switch sends  
out the BPDU packet to check RSTP status. Enter a value between  
1 and 10.  
Forward Delay Time (4-30): the number of seconds a port waits  
before changing from its Rapid Spanning Tree Protocol learning  
and listening state to the forwarding state. Enter a value between 4  
and 30.  
[NOTE]  
Follow this rule to configure the MAX Age, Hello Time, and  
Forward Delay Time.  
2 x (Forward Delay Time value –1) > = Max Age value >= 2 x  
(Hello Time value +1)  
80  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RSTP System Configuration interface  
RSTP - Port Configuration  
Configure path cost and priority of each port.  
1. Select the port in Port column.  
1. Path Cost: The cost of the path to the other bridge from this transmitting  
bridge at the specified port. Enter a number 1 through 200000000.  
2. Priority: Network priority. Enter a number between 0 and 240. The value  
must be a multiple of 16.  
3. P2P: Some of the rapid state transactions that are possible within RSTP  
are dependent upon whether the port concerned can only be connected  
to exactly one other bridge (i.e. it is served by a point-to-point LAN  
segment), or can be connected to two or more bridges (i.e. it is served  
by a shared medium LAN segment). This function allows the P2P status  
of the link to be manipulated administratively. True is P2P enabled.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
81  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
False is P2P disabled.  
4. Edge: The port directly connected to the end stations cannot create a  
bridging loop in the network. To configure the port as an edge port, set  
the port to ‘True’ status.  
Non STP: Set True to disable STP mathematic calculation. Set False  
to including the STP mathematic calculation.  
Apply  
Click  
.
RSTP Port Configuration interface  
82  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SNMP Configuration  
Simple Network Management Protocol (SNMP) is the protocol developed to  
manage nodes (servers, workstations, routers, switches, hubs, etc.) on an  
IP network. SNMP enables network administrators to manage network  
performance, find and solve network problems, and plan for network growth.  
Network management systems learn of problems by receiving traps or  
change notices from network devices implementing SNMP.  
System Configuration  
Community Strings  
Define and remove community strings.  
1. String: Enter the name of the string.  
2. RO: Read only. Enables requests accompanied by this string to display  
MIB-object information.  
3. RW: Read write. Enables requests accompanied by this string to  
display MIB-object information and to set MIB objects  
Add  
4. Click  
button.  
5. To remove the community string, select the community string and  
Remove  
click  
. The default community string cannot be edited.  
Select the SNMP version that you want to use and click  
Agent Mode:  
Change  
Manual Documentation Number: EIR618-2SFP-T_5107m  
83  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SNMP System Configuration interface  
Trap Configuration  
A trap manager is a management station that receives traps (the system  
alerts generated by the switch). If the trap manager is not defined, traps will  
not be issued. Create a trap manager by entering the IP address of the  
station and a community string.  
1. IP Address: Enter the IP address of the trap manager.  
2.  
3.  
Enter the community string.  
Community:  
Select the SNMP trap version type (v1 or v2c).  
Trap Version:  
Add  
4. Click  
5. To remove the community string, select the community and click  
Remove  
.
84  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trap Managers interface  
SNMPV3 Configuration  
Context Table  
Configure SNMP v3 context table. Assign the context name of context table.  
Add  
Remove  
Click  
to add context name. Click  
to remove the  
unwanted context name.  
User Profile  
Configure SNMP v3 user table.  
User ID: Enter the user name.  
Authentication Password: Enter the authentication password.  
Privacy Password: Enter the private password.  
Add  
Click  
Click  
to add the context name.  
Remove  
to remove an unwanted context name.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
85  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SNMP V3 configuration interface  
86  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Group Table  
Configure SNMP v3 group table.  
Security Name (User ID): Assign the user name that you set up in the  
user table.  
Group Name: Set up the group name.  
Add  
Click  
Click  
to add the context name.  
Remove  
to remove an unwanted context name.  
Access Table  
Configure SNMP v3 access table.  
Context Prefix: Set up the context name.  
Group Name: Set up the group.  
Security Level: Set up the access level.  
Context Match Rule: Select the context match rule.  
Read View Name: Set up the read view.  
Write View Name: Set up the write view.  
Notify View Name: Set up the notify view.  
Add  
Click  
Click  
to add the context name.  
Remove  
to remove an unwanted context name.  
MIBview Table  
Configure MIB view table.  
ViewName: Set up the name.  
Sub-Oid Tree: Fill the Sub OID.  
Type: Select the type—excluded or included.  
Add  
Click  
to add the context name.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
87  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remove  
Click  
to remove an unwanted context name.  
QoS Configuration  
QoS Policy and Priority Type  
QoS Policy: select the QoS policy rule.  
¾
Use an 8,4,2,1 weighted fair queuing scheme: The switch will  
follow 8:4:2:1 rate to process the priority queue from the highest to  
the lowest queue. For example, when processing, 1 frame of the  
lowest queue, 2 frames of the low queue, 4 frames of the middle  
queue, and 8 frames of the high queue will be processed at the  
same time.  
¾
Use the strict priority scheme: The highest queue will always  
processed first.  
Priority Type: there are five priority selections available.  
Port-base: the port priority will follow the assigned Port-base – High,  
middle, low, or lowest.  
¾
¾
¾
¾
COS Only: the port priority will only follow the COS priority  
assigned.  
TOS only: the port priority will only follow the TOS priority  
assigned.  
COS first: the port priority will follow the COS priority first, and  
then the other priority rule.  
TOS first: the port priority will follow the TOS priority first, and then  
the other priority rule.  
Apply  
Click  
.
88  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QoS Configuration interface  
Port-based Priority  
Port x: Each port has 4 priority levels—High, Middle, Low, and  
Lowest—to select from.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
89  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Apply  
Click  
button to make the settings effective.  
COS Configuration  
Set up the COS priority level.  
COS priority: Set up the COS priority level 0 to 7 –High, Middle, Low,  
Lowest.  
Apply  
Click  
.
TOS Configuration  
TOS priority: the system provides 0 to 63 TOS priority levels. Each  
level has four types of priority – high, middle, low, and lowest. The default  
value is ‘Lowest’. When an IP packet is received, the system will check the  
TOS level value in the IP packet. For example, if the TOS level 25 is high  
and the port is following the TOS priority policy only, when a packet is  
received, the system will check the TOS value of the received IP packet. If  
the TOS value of received IP packet is 25(priority = high), then the packet  
will have highest priority.  
Apply  
Click  
button to make the settings effective.  
IGMP Configuration  
The Internet Group Management Protocol (IGMP) is an internal protocol of  
the Internet Protocol (IP) suite. IP manages multicast traffic by using  
switches, routers, and hosts that support IGMP. Enabling IGMP allows the  
ports to detect IGMP queries and report packets and manage IP multicast  
traffic through the switch. IGMP has three fundamental types of message.  
90  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Message  
Query  
Description  
A message sent from the querier (IGMP router or switch)  
asking for a response from each host belonging to the  
multicast group.  
A message sent by a host to the querier to indicate that the  
host wants to be or is a member of a given group indicated in  
the report message.  
Report  
A message sent by a host to the querier to indicate that the  
host has quit being a member of a specific multicast group.  
Leave  
Group  
Enable IGMP protocol on the web management switch setting advanced  
page. IP multicast addresses range from 224.0.0.0 through  
239.255.255.255.  
IGMP Protocol: Enable or disable the IGMP protocol.  
Select the IGMP query function (Enable or Auto) to set  
IGMP Query:  
the switch as a querier for an IGMP version 2 multicast network.  
Apply  
Click  
button.  
IGMP Configuration interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
91  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X-Ring  
X-Ring provides network redundancy similar to the Spanning Tree and  
Rapid Spanning Tree Protocols. However, recovery time is greatly reduced  
when the X-Ring protocol is used. The protocol identifies one switch as the  
Ring Master. Packets are blocked from the redundant path unless a ring  
member becomes disconnected from the rest of the network. When this  
happens, the protocol automatically restores connectivity using the  
redundant path.  
In the X-Ring topology, every switch should enable X-Ring function and  
assign two member ports to the ring. Only one switch in the X-Ring group  
would be set as the backup switch. Other switches are called working  
switches and their two member ports are called working ports. If a network  
connection failure occurs, the backup port will automatically become a  
working port to recover.  
The switch can be set in the ring master or slave mode. The ring master  
negotiates and places commands to the other switches in the X-Ring group.  
If there are two or more switches in the master mode, the software will  
select the switch with lowest MAC address number as the ring master. The  
X-Ring master mode is enabled using the X-Ring configuration interface.  
The Ring Master can also be identified using the R.M. LED on the front of  
the switch.  
The switch also supports coupling ring to connect two or more X-Ring  
groups for redundant backup. The dual homing function is used to prevent a  
connection lose between the X-Ring group and the upper level/core switch.  
Enable X-Ring: Mark the check box to enable the X-Ring function.  
Enable Ring Master: Mark the check box to set the switch as the Ring  
Master.  
1st & 2nd Ring Ports: Assign two ports as the member ports. 1st Ring  
Port is the working port and 2nd Ring Port is the backup port. When 1st  
Ring Port fails, the system will automatically upgrade the 2nd Ring  
Port to be the working port.  
92  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Enable Coupling Ring: Mark the check box to enable the coupling ring  
function.  
Coupling port: Assign the member port.  
Control port: Set the switch as the master switch in the coupling ring.  
Enable Dual Homing: Set up one of port on the switch to be the Dual Homing  
port. In an X-Ring group, only one port can be the Dual Homing port. Dual  
Homing only works when the X-Ring function is enabled.  
Apply  
Click  
.
X-ring Interface  
[NOTE]  
1. When the X-Ring function is enabled, disable RSTP.  
2. If the configuration is not saved, it will be lost when the switch  
is powered off.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
93  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Security  
802.1X/Radius Configuration  
802.1x is an IEEE authentication specification that allows a client to connect  
to a wireless access point or wired switch but prevents the client from  
gaining access to the Internet until it proves authority by providing a user  
name and password, which is verified by a separate server.  
System Configuration  
1. IEEE 802.1x Protocol: Enable or disable 802.1x protocol.  
2. Radius Server IP: Enter the Radius Server IP address.  
3. Server Port: Enter the UDP destination port for authentication requests  
to the Radius Server.  
4. Accounting Port: Enter the UDP destination port for accounting  
requests to the Radius Server.  
5. Shared Key: Enter an encryption key for use during authentication  
sessions. This key must match the encryption key used on the Radius  
Server  
6. NAS, Identifier: Enter the identifier of the radius client.  
Apply  
7. Click  
802.1x System Configuration interface  
94  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
802.1x Port Configuration  
You can configure 802.1x authentication state for each port. The State  
choices are Disable, Accept, Reject and Authorize. Use the ‘Space’ key  
change the state value.  
Reject: The port is held in the unauthorized state.  
Accept: The port is held in the Authorized state.  
Authorized: The port will allow an authentication exchange between  
the supplicant and the authentication server.  
Disable: The port is held in the Authorized state  
Apply  
Click  
.
802.1x Per Port Setting interface  
Manual Documentation Number: EIR618-2SFP-T_5107m  
95  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Misc Configuration  
Quiet Period: Sets the period during which the port does not try to  
acquire a supplicant.  
TX Period: Sets the period that the port waits before retransmitting the  
next EAPOL PDU during an authentication session.  
Supplicant Timeout: Sets the period the switch waits for a supplicant  
response to an EAP request.  
Server Timeout: Set the period the switch waits for a server response  
to an authentication request.  
Max Requests: Sets the number of authentications that time-out  
before authentication fails and the authentication session ends.  
Reauth period: Set the period of time after which connected clients  
must be re-authenticated.  
Apply  
Click  
.
802.1x Misc Configuration interface  
96  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAC Address Table  
Use the MAC address table to ensure the port security.  
Static MAC Address  
You can add a static MAC address. This address remains in the switch's  
address table, regardless of whether the device is physically connected to  
the switch. Therefore, the switch does not have to re-learn a device's MAC  
address when the disconnected or powered-off device reconnects to the  
network. You can add / modify / delete a static MAC address.  
Add the Static MAC Address  
You can add static MAC address in the switch MAC table here.  
MAC Address: Enter the MAC address of the port that should  
permanently forward traffic, regardless of the device network activity.  
Port No.: Pull down the selection menu to select the port number.  
Add  
Click  
button.  
If you want to delete the MAC address from filtering table, select the  
Delete  
MAC address and click  
button.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
97  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Static MAC Addresses interface  
MAC Filtering  
MAC Filtering interface  
1. MAC Address: Enter the MAC address that you want to filter.  
Add  
2. Click  
button.  
3. If you want to delete the MAC address from the filtering table, select the  
Delete  
MAC address and click  
button.  
98  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
All MAC Addresses  
You can view the port that connected device’s MAC address and the related  
devices’ MAC address.  
1. Select the port.  
2. The selected port static & dynamic MAC address information will be  
displayed.  
Clear MAC Table  
3. Click  
to clear the port static MAC address.  
All MAC Address interface  
Factory Default  
Reset  
To reset switch to the default configuration, click  
. This function has  
the option of retaining the current IP address and username/password.  
Manual Documentation Number: EIR618-2SFP-T_5107m  
99  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Factory Default interface  
Save Configuration  
Save  
Click  
to save the configuration to the flash memory.  
Save Configuration interface  
System Reboot  
Reboot  
Click  
to reboot the system.  
System Reboot interface  
100  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble shooting  
Verify that 12 to 48VDC power is available. Do not exceed 48VDC.  
Select the proper cable to construct your network. Use unshielded  
twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ-45 connections:  
100Ω Category 3, 4, or 5 cable for 10Mbps connections, 100Ω Category 5  
cable for 100Mbps, or 100Ω Category 5e/above cable for 1000Mbps  
connections. Ensure that the length of any twisted-pair connection does not  
exceed 100 meters (328 feet).  
LED Indicators: The LEDs can be used to diagnose system problems  
Manual Documentation Number: EIR618-2SFP-T_5107m  
101  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specification  
IEEE 802.3 10Base-T  
IEEE 802.3u 100Base-TX  
IEEE 802.3ab 1000Base-T  
IEEE 802.3z Gigabit fiber  
IEEE 802.3x Flow Control and Back-pressure  
IEEE 802.3ad Port trunk with LACP  
IEEE 802.1d Spanning Tree  
Standard  
IEEE 802.1w Rapid Spanning Tree  
IEEE 802.1p Class of Service  
IEEE 802.1Q VLAN Tag  
IEEE 802.1x User Authentication (RADIUS)  
Protocol  
CSMA/CD  
14,880 pps for 10Base-T Ethernet port  
Transfer Rate  
148,800 pps for 100Base-TX/FX Fast Ethernet port  
1,488,000 pps for Gigabit Fiber Ethernet port  
MAC address  
Packet Buffer  
8K MAC address table  
1Mbits  
Per unit: Power (Green), Power 1 (Green), Power 2  
(Green), Fault (Red), Master (Green)  
16 10/100TX: Link/Activity (Green), Full duplex/Collision  
(Yellow)  
LED  
Gigabit Copper: Link/Activity (Green), Speed (1000M  
Green)  
SFP: Link/Activity (Green)  
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5 cable  
EIA/TIA-568 100-ohm (100m)  
Network Cable  
100Base-TX: 2-pair UTP/STP Cat. 5 cable  
EIA/TIA-568 100-ohm (100m)  
102  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1000Base-T: 2-pair UTP/STP Cat. 5e or 6 cable  
EIA/TIA-568 100-ohm (100m)  
LC (Multi-mode): 50/125um or 62.5/125um  
LC (Single mode): 9/125um  
Optical cable  
Back-plane  
7.2Gbps  
Packet throughput  
ability  
10.7Mpps at 64bytes  
12 to 48 VDC  
Power Supply  
Redundant power with reverse polarity protection and  
removable terminal block  
Power  
11.2 Watts  
Consumption  
Install  
DIN Rail and Wall Mount Design  
Operation Temp.  
-40oC to 75oC  
Operation  
Humidity  
Storage  
5% to 95% (Non-condensing)  
-40oC to 85oC  
Temperature  
Case Dimension  
IP-30, 72 mm (W) x 105 mm (D) x 152mm (H)  
FCC Class A  
CE EN61000-4-2 (ESD)  
CE EN61000-4-3 (RS)  
CE EN61000-4-4 (EFT)  
CE EN61000-4-5 (Surge)  
CE EN61000-4-6 (CS)  
CE EN61000-4-8  
EMI  
Manual Documentation Number: EIR618-2SFP-T_5107m  
103  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CE EN61000-4-11  
CE EN61000-4-12  
CE EN61000-6-2  
CE EN61000-6-4  
Safety  
CE/EN60950-1  
IEC60068-2-32 (Free fall)  
IEC60068-2-27 (Shock)  
IEC60068-2-6 (Vibration)  
Stability testing  
104  
Manual Documentation Number: EIR618-2SFP-T_5107m  
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com  
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Modem 3CP3617B User Manual
AEG Freezer AGN71200F0 User Manual
AEG Vacuum Cleaner 1800 User Manual
Aiwa Stereo System NSX A555 User Manual
Alpine Car Stereo System TDM 7544 User Manual
Amana Range AER5830VA User Manual
American Standard Indoor Furnishings 0478001 User Manual
Aspire Digital Laptop 2010 User Manual
ATN Binoculars 7900 User Manual
Bafo Technologies Computer Accessories BF 816 User Manual