Altinex Network Card PNP200 User Manual

ACCESSORIES  
MANUAL PART NUMBER: 400-0057-003  
PRODUCT REVISION: 3  
PNP200 P  
Pop ‘N Plug™ Interconnect Box  
USER'S GUIDE  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
·
·
We recommend using wall outlets with a  
Ground Fault Circuit Interrupter (GFCI) for  
maximum protection.  
PRECAUTIONS / SAFETY WARNINGS  
1
Please read this manual carefully before using your  
PNP200 Interconnect Box. Keep this manual handy  
for future reference. These safety instructions are  
to ensure the long life of your PNP200 and to  
prevent fire and shock hazard. Please read them  
carefully and heed all warnings.  
Install all cables according to the instructions.  
Do not force or pull out any cable or power  
cord that is attached to the PNP200  
Interconnect Box.  
1.3 CLEANING  
1.1 GENERAL  
·
Surfaces should be cleaned with a dry cloth.  
·
·
Unauthorized personnel shall not open the unit  
since there are high-voltage components  
inside.  
Never use strong detergents or solvents, such  
as alcohol or thinner. Do not use a wet cloth or  
water to clean the unit.  
Qualified Altinex service personnel, or their  
authorized representatives must perform all  
service.  
1.4 FCC / CE NOTICE  
·
·
This device complies with part 15 of the FCC  
Rules. Operation is subject to the following two  
conditions: (1) This device may not cause  
harmful interference, and (2) this device must  
accept any interference received, including  
that which may cause undesired operation.  
1.2 INSTALLATION  
·
For best results, place the PNP200  
Interconnect Box in a dry area away from dust  
and moisture.  
This equipment has been tested and found to  
comply with the limits for a Class A digital  
device, pursuant, to Part 15 of the FCC Rules.  
These limits are designed to provide  
·
To prevent fire or shock, do not expose this  
unit to rain or moisture. Do not place the  
PNP200 Interconnect Box in direct sunlight,  
near heaters or heat radiating appliances, or  
near any liquid. Exposure to direct sunlight,  
smoke, or steam can harm internal  
components.  
reasonable  
protection  
against  
harmful  
interference when the equipment is operated  
in a commercial environment. This equipment  
generates, uses, and can radiate radio  
frequency energy and, if not installed and used  
in accordance with the instruction manual, may  
·
·
Handle the PNP200 Interconnect Box  
carefully. Dropping or jarring can damage  
internal components.  
cause  
harmful  
interference  
to  
radio  
Never place fingers inside the openings in the  
back of the unit. This action could cause  
serious injury because of the sharp edges  
inside of the PNP200.  
communications. Operation of this equipment  
in a residential area is likely to cause harmful  
interference in which case the user will be  
required to correct the interference at his own  
expense.  
·
·
Do not place heavy objects on top of the  
PNP200. Do not use excessive force to push  
down on the top of the unit.  
·
Any changes or modifications to the unit not  
expressly approved by Altinex, Inc. could void  
the user’s authority to operate the equipment.  
To turn off main power, disconnect the power  
cord, which powers the power socket on the  
PNP200 pop-up panels only, and unplug the  
9V 500mA-power supply. The power outlet  
socket should be installed as near to the  
equipment as possible, and should be easily  
accessible.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
ABOUT YOUR PNP200  
2
TECHNICAL SPECIFICATIONS  
3
The PNP200 is designed for installation into a  
conference room table. The Pop ‘N Plug™  
Interconnect Box (PNP200) provides a means of  
connecting audio, video, control, and computer  
video sources into a presentation system. It is ideal  
for use together with Altinex computer video  
interfaces. The Pop ‘N Plug™ Interconnect Box can  
either “pop up” into a raised position to provide  
access to connectors or it can be lowered into a  
table when not in use. Using a tower-type  
construction with pneumatic suspension and an  
electromagnetic latching mechanism does this.  
FEATURES/DESCRIPTION  
GENERAL  
PNP200  
Front Panel Standard  
Configuration Connectors  
(side without fuse box)  
Power  
Computer Video  
Composite Video  
Audio, left, right  
Audio  
1 IEC (standard)  
1 15-pin HD-F  
1 Yellow RCA F  
1 Black, 1 Red RCA F  
1 3.5 mm stereo F  
1-RJ-11 F (6-position)  
1 RJ-45 F (8-position)  
1 DB-9 F  
Telephone  
Network  
Control  
The Pop ‘N Plug™ Interconnect Box provides easy  
access to system inputs when they are needed. It  
also removes system inputs when not needed,  
eliminating the obstruction. The Pop ‘N Plug™  
Interconnect Box has two input plates on either side  
of the unit, servicing both sides of a table. Each  
standard plate offers Computer Video (15-pin HD);  
Composite Video (RCA), Audio (RCA), Computer  
Audio (Stereo Mini), Modem (RJ-11), 9-pin D-type  
RS-232 and Network (RJ-45) input connections. All  
signals are passed through to a set of female  
connectors or cables. Several optional connectors  
can be substituted for the standard set of  
connectors.  
Back Panel Standard Configuration Connectors  
(side with fuse box )  
Power  
1 IEC with 10 A fuse  
1 15-pin HD-F  
1 Yellow RCA  
1 Black, 1 Red RCA  
1 3.5 mm stereo  
1-RJ-11  
Computer Video  
Composite Video  
Audio, left, right  
Audio  
Telephone  
Network  
1 RJ-45  
Control  
1 DB-9 F  
Table 1. PNP200 General  
MECHANICAL  
PNP200  
The Pop ‘N Plug™ Interconnect Box is designed for  
use with tables ranging from one to three inches  
thick. It offers an adjustable retaining ring to secure  
the unit flush with the table’s surface. The Pop ‘N  
Plug™ comes in a standard matte black color. The  
top of the unit can be finished to match the table or  
it can be painted another color. This is available on  
the custom per order basis at an additional charge.  
Mechanical  
Width (inches)  
Height (inches)  
Finish  
T° Operating  
T° Maximum  
Humidity  
6.030in (153mm)  
8.230in (209mm)  
Black  
10°C-35°C  
50°C  
90% non-condensing  
Table 2. PNP200 Mechanical  
Power  
Power for Operation  
Power Consumption  
Power Rating (pass through  
connector)  
9V 500mA DC  
Max 10 watts  
90-140 VAC, 2A Max  
Table 3. PNP200 Electrical  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
PNP200 DIMENSIONS  
4
Diagrams: 1A, 1B, 1C, & 1D  
PNP200 DIMENSIONS *(con’t)  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Diagram 2: Back View of PNP200  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
APPLICATION DIAGRAM  
Diagram 3: Application  
5
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Diagram 4: Final Installation  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Diagram 5: Table Cutout Requirements  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
INSTALLATION  
6
Step 1. Make sure the gas spring is not  
compressed when you remove the locking  
screw. To release the gas spring, push  
down and turn the knob in the center of  
the bottom of the PNP200 by 90 degrees.  
Remove the lock down screw from the  
PNP200. The locking screw is the  
smallest silver colored screw that is  
located on the bottom of the unit. Re-  
engage the gas spring by pushing down  
on the knob and turning it back to the  
original position, thereby locking the gas  
spring into place.  
Figure 2: Support Plate  
Step 4. Insert the PNP200 into the table. The  
PNP200 can be adjusted to be flush or at  
exactly the same level as the tabletop.  
Turning the four-socket head set screws  
on the top of the PNP200 does this. An  
allen wrench provided with the PNP200 is  
used to adjust the height level.  
Step 5.Insert the four screws, which are provided,  
into the adjustable retaining ring from  
bottom side of the table. The adjustable  
retaining ring allows securing unit to the  
table. The adjustable retaining ring is a flat  
square plate with two bent edges, that will  
not fit into the hole in the table.  
Figure 1: Gas Spring  
Step 2. Cut an opening into the table’s surface  
using the dimensions of 7.38 in x 6.05in.  
Refer to diagram 5 on page 7 of the  
manual for table cutout requirements.  
Note: The table can be 3 inches or thinner  
in thickness. Always confirm dimensions  
before cutting to insure that specifications  
have not changed.  
Step 3. Place the support plate into the hole in the  
table. The support plate is the square flat  
plate that can fit into the hole in the table  
(See Figure 2).  
Figure 3: Insertion of Screws into the Adjustable  
Retaining Ring  
Step 6. Secure the cables by using the provided  
mounting brackets. There are two  
mounting brackets (See Figure 4). Pass  
the power cord from the side of the  
housing and attach it to the surface with  
the cable-clamp supplied with the PNP200  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
unit. Do not keep the cord too tight or too  
loose (See Diagram 4, page 6).  
CONGRATULATIONS! YOU ARE DONE.  
ENJOY YOUR Pop `N Plug™ Interconnect Box.  
If you experience any problems, please call  
1-800-258-4623 or 1-714-990-2300 for  
international calls.  
OPERATION  
7
Figure 4: Mounting Brackets  
7.1 LOCK, RELEASE, STATUS CONTROL PINS  
Step 7. Make that the provided ground wire  
assembly is secured to the threaded nut  
located on the bottom of the housing of the  
PNP200 with a star-washer and a 4-40  
screw as shown in Diagram 4, page 6.  
To lock the position of the PNP200, connect  
the LOCK pin of the terminal block to GND.  
Note: the power supply is rated at 9V, but  
since the current demand of the PNP200 is  
low, it will reach 12 volts at the terminal block.  
If a regulated power supply is used, it should  
be a 12-volt power supply. A regulated power  
supply is when the power supply is at 12 volts,  
and when the power supply is at 9 volts, it is  
known as unregulated.  
Step 8.Attach the other end of the ground wire  
assembly to a Protective Earth Ground  
with provided 6-32 screw and star-washer.  
Step 9.Connect the appropriate cables with the  
correct input connectors. There are two  
RCA connectors on each side of the  
PNP200. The black connectors are known  
as audio left, whereas the red connectors  
are called audio right. On either side of the  
unit, there is also a RCA video connector,  
which is yellow in color. The network  
connection is red; In addition, the  
telephone or data connection is gray.  
To release the top connector assembly,  
connect the RELEASE pin of the terminal  
block to GND.  
To determine the status of the PNP200,  
examine the STATUS pin. The status pin  
should be a TTL digital level only. When the  
PNP200 is in an up position 5 volts is present,  
whereas 0 volts represents the down position.  
Step 10. Once you have applied power and  
connected the proper cables on the  
bottom of the unit, you may raise the unit.  
To raise the PNP200 into position, press  
the top of the unit.  
7.2 HOW TO RELEASE AND REPLACE THE GAS  
SPRING  
To replace the spring, push up, and turn the  
knob in the center on the bottom of the  
PNP200 by 90 degrees, thereby releasing the  
gas spring.  
Step 11. To lower the unit, push on the top of the  
PNP200 until it fits into place. When the  
9V DC adapter is plugged in, 9 volts must  
be applied. Once the 9 volts have been  
applied, the release top connection will be  
engaged. This mechanism allows the unit  
to lock into place, and then pop up when  
pressure is put on the top of the unit.  
Unscrew the knob, and then unscrew the gas  
spring itself from the PNP200. Replace the  
gas spring with a new one by screwing it in,  
and then replacing the knob.  
Re-engage the new gas spring by pushing up,  
and turning the knob by 90 degrees. After you  
have finished this step, you have completed  
the installation.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
Under normal conditions the gas spring will  
last up to five years.  
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,  
150ft, 200ft, 250ft  
5VMxxxVF  
POWER CABLES  
ACCESSORIES  
Model No.  
8
Power Cable for US  
Power Cable for UK  
Power Cable Australia  
Power Cable Germany  
OPTIONAL CONNECTORS  
Blank Connector (Snap-in and  
15-pin location)  
PC5301US  
PC5302UK  
PC5303AU  
PC5304GR  
Description  
VGA MALE TO MALE (HD-15)  
HIGH RESOLUTION CABLE  
xx = available length of 3ft, 6ft,  
15ft, 25ft, 50ft, 75ft, 100ft,  
150ft  
CB37xxMR  
BNC Female  
VGA MALE TO FEMALE (HD-  
15) HIGH RESOLUTION  
CABLE  
4-pin Mini-DIN  
6-pin Mini-DIN  
xx = available length of 3ft, 6ft,  
15ft, 25ft, 50ft, 75ft, 100ft,  
150ft, 200ft, 250ft  
CB39xxMR  
SUPER HIGH RESOLUTION  
PLENUM-FLEX MULTI-  
CHANNEL COAX CABLE  
VGA MALE TO VGA MALE  
(HD-15)  
xxx = available length of 3ft,  
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,  
150ft, 200ft, 250ft  
CB5000PL-  
5VMxxxVM  
SUPER HIGH RESOLUTION  
PLENUM-FLEX MULTI-  
CHANNEL COAX CABLE  
VGA MALE TO VGA FEMALE  
(HD-15)  
xxx = available length of 3ft,  
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,  
150ft, 200ft, 250ft  
CB5000PL-  
5VMxxxVF  
SUPER HIGH RESOLUTION  
PLENUM-FLEX MULTI-  
CHANNEL COAX CABLE  
VGA MALE TO VGA FEMALE  
(HD-15)  
xxx = available length of 3ft,  
6ft, 15ft, 25ft, 50ft, 75ft, 100ft,  
150ft, 200ft, 250ft  
CB5100PL-  
5VMxxxVM  
SUPER HIGH RESOLUTION  
PLENUM-FLEX MULTI-  
CHANNEL COAX CABLE  
VGA MALE TO VGA FEMALE  
(HD-15)  
xxx = available length of 3ft,  
CB5100PL-  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESSORIES  
that an Altinex product needs to be returned  
please follow the policies below:  
TROUBLESHOOTING GUIDE  
9
The PNP200 supplied unit was carefully tested and  
no problems were detected; however, we would  
like to offer these suggestions.  
Altinex will accept all product returns for a period  
of 30 days from authorized Altinex dealers in an  
unopened package.  
·
Please make sure that the Fuse is of a 10  
Amps rating.  
If a product has been opened, the restocking fees  
will apply. For the restocking fee, please contact  
an Altinex Sales Representative.  
·
Please make sure that the highest quality  
video, audio, network, and telephone cables or  
connectors are used.  
If the product is in your possession for more than  
30 days, the restocking fees will apply.  
Altinex will not accept any returns on cables or  
custom products.  
·
·
Make sure that the 9V DC adapter or the  
external regulated 12 volts is plugged into the  
power.socket for proper operation.  
If your product is in warranty and needs service,  
contact the Altinex Sales Department for an RMA  
(Return Material Authorization). Products returned  
without an RMA number may experience a delay  
in service.  
Make sure that any cable or power cord is not  
damaged or pinched. If it has been damaged,  
then do not use the PNP200 unit. Immediately  
contact the Altinex Customer Service  
Department to have  
If your product is out of warranty and needs  
service, contact the Altinex Sales Department for  
an RMA (Return Material Authorization). Products  
returned without an RMA number may experience  
a delay in service. The service charges will be  
quoted to you before the actual repairs are done.  
ALTINEX POLICY  
10  
10.1 LIMITED WARRANTY  
Altinex warrants that its products and cables are  
free from defects in materials under normal use  
and service. This warranty is limited to repairing at  
company’s factory any part or parts of the product  
that shall within 2 years (90 days for cables) from  
date of shipment to the purchaser be returned to  
company with transportation charges pre-paid.  
The company’s examination shall disclose  
product(s) to be thus defective. The warranty is  
expressly in lieu of all other warranties expressed  
or implied. Altinex neither assumes nor authorizes  
any other person to assume for it any other liability  
concerning the sale of the products. This warranty  
shall not apply to any product that shall have been  
repaired or altered outside of company’s factory in  
any way so as, in its judgment, to affect its  
stability or reliability, or that has been subject to  
misuse, negligence or accident.  
10.3 CONTACT INFORMATION  
Sales Department  
Phone:  
Fax:  
714-990-2300  
714-990-3303  
Accounting Department  
Phone:  
Fax:  
714-990-6088  
714-990-5778  
10.2 RETURN POLICY  
It is very important to Altinex that you receive all  
products that you have ordered and that this  
product fulfills your needs. In the unlikely event,  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Abocom Network Router P3102 4g User Manual
Acoustic Research Headphones ARWH1 User Manual
ADC Laser Level P 80 412 User Manual
Addonics Technologies Network Card RCMR256I User Manual
Allied Telesis Switch 54266 02 User Manual
Amana Microwave Oven AMC6158BAB User Manual
American Standard Outdoor Shower 078016 0020A User Manual
AMX Stereo Receiver MAX CSD 10 User Manual
Avocent Network Card CS4008 User Manual
Bakers Pride Oven Oven D 125 DSP User Manual