Aiphone Intercom System FK1629 B 0811YZ User Manual

FK1629 B 0811YZ  
IS SERIES  
Commercial & Security IP Video Intercom system  
Network Direct System  
SETTING MANUAL  
Thank you for selecting Aiphone for your communication and security needs. Please read this manual and the separate  
“OPERATION MANUAL” carefully before setting and using this system.  
*
Refer to the provided “INSTALLATION MANUAL” for complete information regarding this system.  
IMPORTANT  
Please read and understand the system setting procedures before beginning the setup process.  
Please note that images and illustrations depicted in this manual may differ from the actual ones.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ABOUT THIS MANUAL  
The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your  
system.  
Manual congurations  
The following manuals are provided for a network direct system. Read all the manuals for installing, setting up, and using a network  
direct system, or provide the manuals to the persons working with the system.  
INSTALLATION MANUAL (A booklet included with the IP master station (IS-IPMV))  
Used for installing and connecting IP master stations and IP video door stations. (For an installer or serviceman)  
SETTING MANUAL (This manual on the CD-ROM included with the IP master station (IS-IPMV))  
This manual describes how to make the system settings and system maintenance. (For an installer or serviceman)  
OPERATION MANUAL (An electronic manual on the CD-ROM included with the IP master station (IS-IPMV))  
Information for using the system for calling, communicating, paging, monitoring, etc. (For users of the system)  
Note the following:  
This manual describes how to make the system settings for a network direct system (without an IP control unit) only. For a standard  
(IP) system (including one or more IP control units), refer to the “SETTING MANUAL” for the standard (IP) system.  
Master stations and door stations that can be used in a network direct system are IP units (IS-IPMV, IS-IPDV, IS-IPDVF and IS-  
SOFT) only.  
PC master stations (IS-SOFT) can also be used in a network direct system. For setting a PC master stations (IS-SOFT), refer to  
the “SETTING MANUAL” for the PC master station (IS-SOFT).  
PURPOSE OF THE SYSTEM SETTINGS  
Congure the system settings based on how your system is planned to be used. System settings must be completed before the  
system will operate.  
CAUTION:  
Make the settings correctly. If the settings are not made correctly, the system will not function as planned.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTING LIST  
The following is the list of system settings you can make via the web browser. The titles or items in shaded cells are required.  
NOTES:  
The following list is a brief overview of the setting items available in the system settings on a PC. The descriptions, and the style and order of  
descriptions do not necessarily equate with the actual displays.  
The following list describes the setting contents required only for a network direct system. The actual setting windows of the web browser also  
includes contents not described in the list.  
Make a note of the setting results you have made by using the “Setting Information Memo” ( P. 30) etc. in case of unexpected data erasure, and  
keep it in a safe place not to lose it.  
Title  
Sub title  
Item  
(Language)  
Sub item  
Setting range  
English/French/German/Spanish/Dutch/ English  
Italian/Japanese  
Default  
-
-
-
Network setting Network setting:  
Individual  
IP version  
Host unit setting  
-
-
IPv4  
IPv4  
Client unit  
-
Host unit/Client unit  
Host unit IP address (available (Enter the Host unit IP address.)  
when [Host unit setting] is set to  
“Client unit”)  
System name  
-
Up to 24 alphanumeric characters  
-
(available when [Host  
unit setting] is set to  
“Host unit”)  
(Select the network  
setting method.)  
-
DHCP/Static IP Address  
DHCP  
Static IP Address  
Static IP Address (required when 0 – 255 (for each eld)  
[Static IP Address] is selected)  
192.168.0.40  
255.255.255.0  
Subnet Mask (required when  
[Static IP Address] is selected)  
0 – 255 (for each eld)  
Default Gateway  
Primary DNS Server  
Secondary DNS Server  
-
-
0 – 255 (for each eld)  
0 – 255 (for each eld)  
0 – 255 (for each eld)  
(Unmodiable)  
Up to 24 alphanumeric characters  
(except accent marks, umlaut marks,  
etc.)  
-
-
-
MAC address  
Unit name  
(Unmodiable)  
-
Web port  
Connection port  
Connection  
Password  
-
-
-
(Unmodiable)  
1024 - 65535  
Up to 16 alphanumeric characters  
(Unmodiable)  
5060  
aiphone  
Network setting:  
Common  
UPnP  
Global IP address  
(available when  
-
-
ON/OFF  
0 - 255 (for each eld)  
ON  
-
[UPnP] is set OFF)  
Connection port:  
global  
Multicast address  
1 - 5 (“Multicast  
address 3” is not  
available.)  
-
-
(Unmodiable)  
(Unmodiable)  
239.0.0.0 - 239.255.255.255  
1: 239.0.1.1  
2: 239.0.1.2  
4: 239.0.1.4  
5: 239.0.1.5  
Audio/video port  
-
1024 - 65535  
50800 - 50813  
Administrator  
setting  
-
-
New administrator ID -  
Up to 16 alphanumeric characters  
Up to 16 alphanumeric characters  
Up to 16 alphanumeric characters  
Up to 16 alphanumeric characters  
-
Current Password  
New Password  
New Password  
(Re-type)  
-
-
-
- (aiphone)  
-
-
IP unit search  
-
-
-
-
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Title  
Sub title  
Item  
Sub item  
Setting range  
Default  
System setting Area/Site  
registration  
Area/Site Name  
-
Up to 24 alphanumeric characters (for  
up to 99 areas including sites)  
* Up to 31 for sites  
1 (for Area  
number 01)  
Area/Site  
IP Address (sites  
only)  
-
-
Area/Site  
0 - 255 (for each eld)  
Area  
-
Port number (sites  
only)  
Connection  
Password (sites only)  
Door release (sites  
only)  
-
-
-
-
-
1024 - 65535  
-
Up to 16 alphanumeric characters  
ON/OFF  
-
ON  
Zone registration Zone name  
Up to 24 alphanumeric characters (for  
up to 99 zones)  
IP video door station, IP master station,  
PC master station  
-
-
IP unit registration Station type  
MAC address  
Unit name  
Port number  
Area  
Station number  
-
-
-
-
-
-
-
-
Up to 24 alphanumeric characters  
1024 - 65535  
(Area) 01 to 99  
50900 - 50902  
(Area) 01  
-
Registering  
stations  
001 to 999  
0001 to 9999  
00001 to 99999  
Station name  
Station type  
-
-
Up to 24 alphanumeric characters  
(Unmodiable)  
-
(Unmodiable)  
Advanced station Video door station  
settings  
Call priority  
Called stations  
Normal/Priority/Urgent  
(Set up to 20 targets from the registered -  
ones.)  
Normal  
Transmit volume boost ON/OFF  
OFF  
at PTT  
(ON: approx. +6dB up)  
Camera zoom image 0 (wide)/1/2/3/4/5/6/7/8/9 (zoom)  
preset  
Call acknowledge tone ON/OFF  
on/off  
5 (Center)  
ON  
Backlight adjustment Exposure +/Exposure -  
Exposure +  
-
Master station  
Stations to be scan monitored  
(Select up to 20 sub stations from the  
registered ones.)  
Master station function: ON/OFF  
ON  
paging, chime, monitor,  
door release, and  
remote site call  
Zone setting  
Zone number  
Stations  
-
-
-
-
-
(Select from the registered ones.)  
(Select from the list.)  
DT1/DT2  
Up to 24 alphanumeric characters  
Hour: 0 to 23  
-
-
Transfer setting Registering daily Schedule number  
DT1  
-
-
transfer schedule  
Schedule name  
Call transfer time  
Minute: 0 to 59  
(Set to the Start time and End time  
individually.)  
Transfer schedule Weekly schedule  
setting  
(Repeat setting)  
Every week/Every other week  
From the current day to 1 year ahead  
From the start day to 1 year ahead  
None/DT1/DT2 (for each day of the  
week)  
Every week  
-
-
Schedule start date  
Schedule end date  
(Transfer schedule)  
None  
Individual schedule (Date)  
From the current day to 1 year ahead  
(Select from the registered ones.)  
Hour: 0 to 23  
-
Daily transfer schedule  
Call transfer time  
None  
-
Minute: 0 to 59  
(Set to the Start time and End time  
individually.)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Title  
Sub title  
Item  
Sub item  
Setting range  
Default  
Timer setting  
-
Call  
Normal/Priority/Urgent  
10 to 600 (sec.), 0 (Unlimited)  
Normal: 30 (sec.)  
Priority: 90 (sec.)  
Urgent: 0  
(Unlimited)  
Communication  
In Local (Not available)  
30 to 600 (sec.) (Not used for network  
direct system)  
60 (sec.)  
Via IP  
30 to 600 (sec.)  
60 (sec.)  
Telephone (Not available)  
30 to 600 (sec.) (Not used for network  
direct system)  
120 (sec.)  
Paging  
Monitor  
Scan monitor:  
Switching  
-
-
-
30 to 600 (sec.)  
10 to 600 (sec.)  
5 to 60 (sec.)  
60 (sec.)  
60 (sec.)  
7 (sec.)  
Contact output  
(Not available)  
External sound source 1  
External sound source 2  
-
10 to 300 (sec.)  
10 to 300 (sec.)  
0 to 300 (sec.), (0: Released while  
30 (sec.)  
30 (sec.)  
10 (sec.)  
Door release  
holding the Door release button pressed.)  
Remote site  
pilot call setting  
-
Remote site master Normal/Priority/Urgent  
call  
(Select one from the registered stations  
in your site for each of “Normal”, “Priority”  
and “Urgent”.)  
(Select up to 20 stations from the  
registered master stations in your site for  
each of “Normal”, “Priority” and “Urgent”.)  
(Select up to 20 stations from the  
registered master stations in your site for  
each of “Normal”, “Priority” and “Urgent”.)  
-
-
-
Remote site door call Normal/Priority/Urgent  
Remote site room  
sub call (available  
when the remote site  
is a standard (IP)  
system that includes  
room sub stations  
(IS-RS).)  
Normal/Priority/Urgent  
Remote site paging Normal/Priority/Urgent/  
Broadcast  
(Select one from the registered zones in -  
your site for each of “Normal”, “Priority”,  
“Urgent” and “Broadcast”.)  
Video setting  
-
-
Frame Rate  
Quality  
Set current time  
-
-
1/2/5/7.5/10/15 (fps)  
Low, Middle, High, Excellent  
Year: 2009 to 2099  
Month: 1 to 12  
Day: 1 to 31  
15 (fps)  
Excellent  
(Internal time  
of the IP Host  
unit)  
Time and date  
setting  
Manual setting  
Hour: 0 to 23  
Minute: 0 to 59  
Second: 0 to 59  
Synchronized with PC  
-
-
NTP  
Synchronized with NTP server ON/OFF  
OFF  
-
123  
0
NTP server*1  
IP address or domain name  
1 to 65535  
-12 to +13 (h)  
NTP port number*1  
(UTC time zone*1)  
Hour difference*1  
(UTC time zone*1)  
-45/-30/0/+30/+45 (m)  
0
Minute difference*1  
Synchronize interval  
Starts*2 Month  
1 to 240 (h)  
ON/OFF  
JAN to DEC (M)  
1st to 4th (W)/The last  
Sunday to Saturday  
0 to 23 (h)  
24 (h)  
OFF  
JAN  
1st  
Sunday  
-
-
JAN  
1st  
Sunday  
-
-
1
0
Daylight savings time -  
Day  
(Week)  
(Day)  
Hour  
(Hour)  
(Minute)  
0 to 59 (m)  
Ends*2 Month  
Day  
JAN to DEC (M)  
1st to 4th (W)/The last  
Sunday to Saturday  
0 to 23 (h)  
0 to 59 (m)  
0 to 12 (h)  
(Week)  
(Day)  
Hour  
(Hour)  
(Minute)  
Hour difference*2  
Minute difference*2  
0/30/45 (m)  
*1: Available only when [Synchronized with NTP server] is set to ON.  
*2: Available only when [Daylight savings time] is set to ON.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Title  
Sub title  
Item  
Sub item  
Setting range  
Default  
E-mail setting  
-
Email destination  
address  
Email source  
address  
1/2/3  
-
Up to 256 alphanumeric characters  
-
-
Up to 256 alphanumeric characters  
SMTP authentication SMTP server  
SMTP server port  
Up to 256 alphanumeric characters  
1 to 65535  
-
465  
(Email) login ID  
Password  
-
Up to 256 alphanumeric characters  
Up to 64 alphanumeric characters  
English/French/German/Spanish/Dutch/ English  
Italian/Japanese  
-
-
Language selection  
Mailing event  
Call: Normal  
Call: Priority  
Call: Urgent  
System start  
Data communication error in the ON/OFF  
system  
ON/OFF  
ON/OFF  
ON/OFF  
ON/OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
Setting le  
Downloading  
setting data  
Uploading setting  
data  
-
-
-
-
-
-
-
-
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
SYSTEM SETTING FLOW  
First of all, make the network settings. The network setting method differs according to the network environment. Select the ow  
suitable for your network environment from the chart below, and start the network settings after you fully understand it. After the  
network settings are nished, make the other individual system settings. See P. 15-28 for the system setting details.  
NOTE:  
The system settings should be made mainly on the IP host unit in the system (in a site). You select one as the IP host unit among the IP units  
connected to the system and others as the IP client units. (A PC master station (IS-SOFT) cannot be used as the IP host unit.)  
First select the Flow 1 , Flow 2 or Flow 3 from the chart below, then start the network settings by  
following the selected ow.  
START  
Do you communicate with remote sites (calling, call transferring,  
paging, etc.)?  
YES  
NO  
(*4)  
(*3)  
NO  
NO  
Do you use a router on which UPnP functions,  
and does UPnP function normally?  
(*1)  
YES  
Do you have a DHCP server (or router that  
has a DHCP server function) in the network,  
and does it have an automatic IP address-  
assigning function?  
Do you have a DHCP server (or router that  
has a DHCP server function) in the network,  
and does it have an automatic IP address-  
assigning function?  
YES  
NO  
(*3)  
YES  
(*2)  
Flow 1  
Flow 2  
(IP host unit: A static IP address is set,  
(All units: Static IP addresses are set)  
IP client units: IP addresses are assigned by the DHCP  
server automatically)  
Go to P. 10.  
Go to P. 9.  
NOTE:  
If you connect a PC master station (IS-SOFT) to the network, install the software (IS-SOFT) to a PC before connecting it to the network.  
(*1): UPnP may not function normally depending on the router. Refer to [System log][UPnP operation check result] (P. 29) on the  
IP host unit. If the [System log] window shows that UPnP is not functioning normally, the UPnP function of the router cannot be  
used with this system. In that case, set [UPnP] to OFF at [Network setting: Common] (P. 16) and then make settings on the  
router again by conrming the settings at [IP unit registration] (P. 19). See http://www.aiphone.net/ for the router to which the  
operartion check has nished and setting examples.  
(*2): If the DHCP server (or router that has a DHCP server function) has a function to assign a static IP address to a specied MAC  
address, you can make the DHCP server assign the IP addresses to all the IP units automatically.  
(→  
(All units: IP addresses are assigned by the DHCP server automatically) (P. 11))  
Flow 3  
(*3): Set [UPnP] to ON at [Network setting: Common] (P. 16) (Default: ON).  
(*4): Set [UPnP] to OFF at [Network setting: Common] (P. 16) (Default: ON).  
If you communicate with remote sites (calling, call transferring, paging, etc.), make the remote site connection settings (P. 12)  
after the network settings for your site have nished.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flow 1  
(IP host unit: A static IP address is set,  
IP client units: IP addresses are assigned by the DHCP server automatically)  
* This is the outline of setting ow. Also make the detailed settings on each setting window referring to the corresponding pages.  
START  
: Settings on the IP host unit  
Write down the MAC addresses of all the IP units to be used  
in the system in advance by using the “Setting Information  
Memo” (P. 30) etc.  
: Settings on the IP client units  
*
The MAC address is labeled on each unit.  
(When making the IP host unit settings  
after connecting the units to the network)  
Decide the static IP address for the IP unit to be used as the  
IP host unit.  
*
Use an address out of the range of DHCP assignment for the IP host  
unit in order to prevent the address for the IP host unit being assigned  
to another IP client unit by an inuence of the turn-on order between  
the IP host unit and the router (that has a DHCP server function) etc.  
(When making the IP host unit settings  
before connecting the units to the network)  
Connect the IP host unit and the PC used for settings  
Connect the units and the PC used for settings to the  
network, and then turn them on.  
directly, and then turn them on. After a while, access  
"https://192.168.0.40/" from the browser on the PC. (P. 14)  
NOTES:  
When connecting a PC to the IP unit directly, use an Ethernet  
crossover cable.  
Search for the IP address of the IP host unit from the MAC  
address of the IP host unit by using IS_IPSEARCH.exe (in the  
CD-ROM included with the IP master station (IS-IPMV)). (If  
the address does not appear, repeat this step until it appears.)  
Then access the address from the browser on the PC. (P. 14)  
If a warning dialog box for security or guarding against virus  
programs appears when accessing the web browser, give permission.  
(Log in.)  
Make the [Network setting: Individual] settings on the IP  
host unit. (P. 16)  
*
*
This address is the temporary one for the initial setting.  
Set it as "Host unit".  
*
Set the static IP address to the IP host unit.  
(Log in.)  
Make the [Network setting: Individual] settings on the IP  
host unit. (P. 16)  
Update the system at [Updating the system]. (P. 28)  
*
Set it as "Host unit".  
*
Set the static IP address to the IP host unit.  
Connect the units and the PC used for settings to the  
network, and then turn them on.  
(IP addresses are assigned to the IP client units by the  
DHCP server automatically.)  
Update the system at [Updating the system]. (P. 28)  
Search for the IP units (other than PC master stations) you  
will use in the system at [IP unit search] on the IP host unit,  
and open the setting window for each IP unit. (P. 17)  
Make the [Network setting: Individual] settings on the IP  
client units. (P. 16)  
*
*
*
Set them as "Client unit" (if they are not set as "Client unit").  
Enter the IP address of the IP host unit.  
Select "DHCP" for acquiring IP addresses (if "DHCP" is not selected).  
Add IP units you will use in the system at [IP unit  
registration] on the IP host unit. (P. 19)  
Update the system at [Updating the system]. (P. 28)  
If you will connect your site with remote sites, make the  
remote site connection settings. (P. 12)  
Conrm the [Network setting: Common] settings on the IP  
host unit. (P. 16)  
*
Conrm that the multicast addresses and/or port numbers do not overlap those  
of other manufacturer’s network devices connected to the same network.  
Make the other system settings. (P. 17-28)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flow 2  
(All units: Static IP addresses are set)  
* This is the outline of setting ow. Also make the detailed settings on each setting window referring to the corresponding pages.  
START  
: Settings on the IP host unit  
Write down the MAC addresses of all the IP units to be  
used in the system in advance by using the “Setting  
Information Memo” (P. 30) etc.  
: Settings on the IP client units  
*
The MAC address is labeled on each unit.  
For the IP host unit  
Decide the static IP address for each IP unit.  
Connect the IP host unit and the PC used for settings  
directly, and then turn them on. After a while, access  
"https://192.168.0.40/" from the browser on the PC.  
(P. 14)  
Make the [Network setting: Individual] settings on each  
IP unit individually. (P. 16)  
NOTES:  
When connecting a PC to the IP unit directly, use an  
Ethernet crossover cable.  
If a warning dialog box for security or guarding against virus  
programs appears when accessing the web browser, give permission.  
Connect the units and the PC used for settings to the  
network, and then turn them on respectively.  
(Log in.)  
Conrm the [Network setting: Common] settings on the  
IP host unit. (P. 16)  
Make the [Network setting: Individual] settings on the  
IP host unit. (P. 16)  
*
Conrm that the multicast addresses and/or port  
numbers do not overlap those of other manufacturer’s  
network devices connected to the same network.  
*
*
Set it as "Host unit".  
Set the static IP address to the IP host unit.  
Update the system at [Updating the system]. (P. 28)  
Add IP units you will use in the system at [IP unit  
registration] on the IP host unit. (P. 19)  
(The selected unit is added in the list whenever selected.)  
For each IP client unit  
If you will connect your site with remote sites, make the  
remote site connection settings. (P. 12)  
Connect an IP client unit and the PC used for settings  
directly, and then turn them on. After a while, access  
"https://192.168.0.40/" from the browser on the PC.  
(P. 14)  
NOTES:  
Make the other system settings. (P. 17-28)  
When connecting a PC to the IP unit directly, use an  
Ethernet crossover cable.  
If a warning dialog box for security or guarding against virus  
programs appears when accessing the web browser, give permission.  
(Log in.)  
Make the [Network setting: Individual] settings on the  
IP client unit. (P. 16)  
*
Set it as "Client unit".  
*
*
Enter the IP address of the IP host unit.  
Set the static IP address to the IP client unit.  
Update the system at [Updating the system]. (P. 28)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Flow 3  
(All units: IP addresses are assigned by the DHCP server automatically)  
* This is the outline of setting ow. Also make the detailed settings on each setting window referring to the corresponding pages.  
START  
: Settings on the IP host unit  
Write down the MAC addresses of all the IP units to be used  
in the system in advance by using the “Setting Information  
Memo” (P. 30) etc.  
: Settings on the IP client units  
*
The MAC address is labeled on each unit.  
Set the router (or DHCP server) so that it assigns a static IP  
address to the IP unit to be used as the IP host unit.  
Connect the units and the PC used for settings to the  
network, and then turn them on.  
Access the IP address assigned to the IP host unit from the  
browser on the PC. (P. 14)  
(Log in.)  
Make the [Network setting: Individual] settings on the IP  
host unit. (P. 16)  
*
*
Set it as "Host unit".  
Select "DHCP" for acquiring an IP address.  
Update the system at [Updating the system]. (P. 28)  
Conrm the [Network setting: Common] settings on the IP  
host unit. (P. 16)  
Search for the IP units (other than PC master stations) you  
will use in the system at [IP unit search] on the IP host unit,  
and open the setting window for each IP unit. (P. 17)  
*
Conrm that the multicast addresses and/or port numbers  
do not overlap those of other manufacturer’s network  
devices connected to the same network.  
Add IP units you will use in the system at [IP unit  
registration] on the IP host unit. (P. 19)  
Make the [Network setting: Individual] settings on the IP  
client units respectively. (P. 16)  
*
Set them as "Client unit" (if they are not set as "Client unit").  
*
*
Enter the IP address of the IP host unit.  
Select "DHCP" for acquiring IP addresses (if "DHCP" is not  
selected).  
If you will connect your site with remote sites, make the  
remote site connection settings. (P. 12)  
Update the system at [Updating the system]. (P. 28)  
Make the other system settings. (P. 17-28)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remote site connection settings  
You need to make the remote site connection settings to enable communication between your site and remote sites. Make the settings  
by following the procedure below after the network settings for your site have nished.  
* This is the outline of setting ow. Also make the detailed settings on each setting window referring to the corresponding pages.  
Procedure  
: Settings on the IP host unit  
Complete the network settings for your site by following  
: Required when [UPnP] is set  
to OFF at [Network setting:  
Common] (P. 16)  
. (P. 9-11)  
Flow 1 , Flow 2 or Flow 3  
Get the following information for the remote sites you will  
connect with your site.  
"Global IP address"  
"Connection port: global"  
"Connection Password"  
Set the following setting items on the IP host unit. (P. 16)  
[Network setting: Individual] :  
"Default Gateway"  
[Network setting: Common] :  
"UPnP"  
"Global IP address"  
"Audio/video port"  
Make the [Area/Site registration] on the IP host unit. (P. 18)  
* Select "Site" with the "Area/Site" pull-down menu and enter  
the information of the site you will connect.  
Update the system at [Updating the system]. (P. 28)  
Open the [IP unit registration] window on the IP host unit,  
Port forwarding setting  
and then click the  
button. (P. 19)  
*
Another window opens and the port forwarding setting  
contents are displayed.  
Set the router with the port forwarding setting contents you  
conrmed in the previous step.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
STARTING UP THE SYSTEM AND PREPARING FOR THE SETTINGS  
The system settings are mainly made on the PC by accessing the web browser for the settings incorporated with the IP unit as the IP  
host unit. It is recommended to use only one PC for the settings that is connected to the system.  
System requirements for PC  
Your PC and operating environment must meet the following system requirements to make the settings.  
Network  
10BASE-T Ethernet, 100BASE-TX Ethernet  
Web browser  
Internet Explorer 6.0 or later (with Internet Options SSL 3.0 enabled)  
Starting up the system  
Connect a PC to the IP unit.  
[When connecting a PC to the IP unit directly]  
1
[When connecting a PC to the IP unit via a hub  
(switch)]  
IP master station  
(IS-IPMV)  
IP video door station  
(IS-IPDV or IS-IPDVF)  
IP master station  
(IS-IPMV)  
IP video door station  
(IS-IPDV or IS-IPDVF)  
or  
or  
LAN/PoE  
LAN/PoE  
RJ45  
PC  
RJ45  
CAT5e/6 (Crossover cable)  
RJ45  
100m (330')  
10BASE-T/100BASE-TX  
CAT5e/6  
(Straight-through cable)  
100m (330')  
10BASE-T/  
100BASE-TX  
NOTES:  
RJ45  
RJ45  
Hub  
(Switch)  
When connecting a PC to the IP unit directly, use an Ethernet  
crossover cable.  
The IP address of IP unit is set to (192.168.0.40) and Subnet  
Mask is set to (255.255.255.0) as default. Change the IP  
address of your PC if needed.  
CAT5e/6  
(Straight-through  
cable)  
100m (330')  
10BASE-T/  
100BASE-TX  
RJ45  
(Continued on next page)  
PC  
NOTES:  
Be sure to connect the CAT5e/6 cable to the LAN ports of both  
units.  
The IP address of IP unit is set to (192.168.0.40) and Subnet  
Mask is set to (255.255.255.0) as default. Change the IP  
address of your PC if needed.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Turn on the power to the IP unit.  
2
*
If the unit is connected to a switch or injector that has  
a PoE function, the power is being supplied. If a power  
supply unit is connected to the unit, turn on the power of  
the power supply unit.  
*
*
Turn on all the units constituting the system depending  
on the network setting method.  
The status LED of an IP video door station changes from  
red lighting to orange blinking.  
(When the settings have correctly made, it changes to  
orange lighting.)  
The status LED of an IP master station changes from red  
lighting to red blinking.  
(When the settings have correctly made, it turns off.)  
Start up the PC, and then open the browser window.  
3
4
Enter the (static) IP address assigned to the IP unit  
to access the web browser for settings.  
192.168.0.40/  
English  
After selecting  
as the target language, the login  
window of the web browser is displayed.  
Log in to the system by setting the following items.  
5
ID  
Enter “aiphone”.  
Password  
Enter “aiphone”.  
Login  
Login  
Click  
to display the setting window.  
*
When you log in for the rst time, the [Registration]  
window appears. Register your system as needed.  
(When registering your system, if you use an IS-SOFT in  
the system, enter the license key of the IS-SOFT.)  
NOTE:  
Be sure not to log in to the system more than once at the same  
time by opening multiple browser windows on the PC.  
Go to the next page.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
THE SYSTEM SETTING DETAILS  
The basic setting procedure  
When you have logged in to the system, the setting window appears. You can make the settings on this window.  
*
*
Make sure to refer to the on-screen instructions and comments displayed on each window when you make the settings.  
Depending on the PC and its OS or environment, the display may differ.  
<Setting window example>  
Setting contents display area  
The setting items of the selected setting title and their  
details are displayed here.  
Table of contents  
Instructions area  
The instructions for settings are  
displayed here.  
Temporarily stored  
The setting titles are listed here.  
Click the title on which you want  
to make the settings to display the  
corresponding setting window.  
Click this to save the current setting results  
temporarily.  
* This temporary storing will not update the  
system with the new setting results. To update  
the system, click the title “Updating the system”  
and follow the necessary procedure.  
NOTE:  
The setting titles not required for a  
network direct system are also grayed  
out.  
The setting procedure  
Click a title in the table of contents on which you wish to make the settings.  
The setting window of the title is displayed.  
1
Make the settings on the setting items individually.  
2
3
Temporarily stored  
When you have nished making the settings on the current window, click  
results temporarily.  
to save the setting  
*
If you wish to cancel the setting results you have made, click a title in the table of contents or “Refresh” in the web browser  
menu. (If you change the current window to another without storing the setting results temporarily, a pop-up window appears  
asking if you want to store the results temporarily or not.)  
Repeat step 1 to 3 to make the settings on the other titles.  
To log out of the system, click [Logout] in the table of contents.  
4
*
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The following shows the setting procedure for the items of each title.  
Refer to “SETTING LIST” (P. 4-7) for details about the settings. Make the settings by also referring to the on-screen instructions.  
Making network settings to each IP unit  
[Network setting: Individual]  
When the settings on this window have nished, update  
the system from [Updating the system]. (P. 28)  
4
Make the settings for network to each IP unit connected  
to the system according to your requirements.  
Making network settings for the whole  
system [Network setting: Common]  
Click Network setting: Individual in the table of  
contents.  
1
Make the network settings for the whole system on the  
web browser of the IP host unit.  
Click Network setting: Common in the table of  
contents.  
1
Make the settings on the following items displayed in  
the setting window.  
2
[Host unit setting]:  
Set this unit as either “Host unit” or “Client unit”. When set to  
“Client unit”, also enter the IP address of the IP host unit.  
[System name]:  
Required  
Make the settings on the following items displayed in  
the setting window.  
2
When “Host unit” is selected at [Host unit setting], it is  
required to enter a name for this system.  
Selecting the network setting method  
Set a (static) IP address to this unit. Select the method for acquiring  
a (static) IP address between [DHCP] and [Static IP Address].  
[UPnP]:  
If you do not use UPnP, set [UPnP] to OFF.  
[Global IP address]:  
[DHCP]:  
When [UPnP] is set to OFF, enter the static global IP  
address of the router for use in your site.  
Check this when you will acquire an IP address with DHCP  
.
*
A DHCP server (or a router) is required to acquire an  
IP address with DHCP. A router may not have the setup  
[Multicast address 1 – 5]:  
Required  
function depending on some models. For information about  
setting a router, see the instruction manual for the router.  
Enter the multicast addresses for the following:  
1: For sound communication for paging between sites  
2: For sound communication for paging in your site  
3: (Not available)  
4: For video communication in your site  
5: For video communication between sites  
[Static IP Address]:  
Check this when you set the static IP address manually,  
and then enter the static IP address suitable for the  
network you are using, subnet mask, etc.  
*
It is required to enter the static IP address and  
subnet mask.  
*
Do not use multicast addresses that overlap those of  
other devices connected to the same network.  
[Unit name]:  
[Audio/video port]:  
Required  
Enter a name for this unit.  
Enter the port numbers used for audio and video  
communication.  
* This name is used for searching for this unit in the  
network. If not named, this unit is recognized only by  
the unit (station) type and MAC address.  
*
Do not use port numbers that overlap those of other  
devices connected to the same network.  
[Connection port], [Connection Password]:  
Required  
Enter the port number for controlling communication and  
the password for security. Use the same port number  
and password among the IP host unit and IP client units  
within the site.  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
NOTES:  
The IP host unit must not have an IP address identical to the IP  
address of a remote site’s IP host unit.  
The items that cannot be entered or selected are grayed out.  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the administrator ID and password  
[Administrator setting]  
Conrming the IP units connected to the  
system [IP unit search]  
We recommend that you change the administrator ID and  
password from default to unique ones for security purposes.  
Before conguring system wide settings, conrm the IP  
units are connected to the network, and set the network  
setting for each IP unit using [IP unit search].  
*
*
This setting can be made to each of the IP units in your site.  
“aiphone” is preset as the default for both ID and password.  
Click IP unit search in the table of contents.  
1
Click Administrator setting in the table of contents.  
1
2
IP unit search  
Click  
.
2
All the IP units connected to the system are displayed in  
the list.  
Make the settings on the following items displayed in  
the setting window.  
*
If IP units are not displayed, repeat this step until  
displayed.  
[New administrator ID]:  
Enter the new ID.  
Conrm the “Station type”, “MAC address” and “Unit  
name” of the IP units in the list.  
3
4
[Current Password]:  
Enter the current password.  
[New Password]:  
To make or change settings to an IP unit,  
check the box for the target IP unit and click  
Enter a new password.  
Open the setting window  
.
[New Password (Re-type)]:  
Another window opens. You can make settings for the  
Enter the new password again.  
target IP unit individually. (P. 16)  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
Close the window.  
5
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
*
Repeat step 3 to 5 to make settings to other IP units.  
NOTE:  
NOTES:  
The system administrator must keep the ID and password without  
fail. If you forget the ID and password, you must initialize the unit,  
thus all the setting contents return to default.  
This procedure cannot search for PC master stations (IS-SOFT)  
and it is not a system failure. To add a PC master station (IS-SOFT)  
in the system, install the application (IS-SOFT) to a PC before  
connecting it to the network and see page 19.  
It may be required to log in to open the setting window, and update  
the system at [Updating the system] before closing the window.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering areas and remote sites  
[System setting – Area/Site registration]  
Required  
Registering zones  
[System setting – Zone registration]  
Register zones for paging (transmitting announcements) in  
your site. The number to which a name is entered is registered  
as a zone number. Up to 99 zones can be registered.  
Register areas (for separating stations in your site) and/  
or remote sites. The number to which a name is entered is  
registered as an area or site number. Up to 99 areas and/or  
sites (up to 31 for sites only) can be registered.  
* Zones are groups of stations designated for paging.  
Click Zone registration in the table of contents.  
1
Click Area/Site registration in the table of contents.  
1
Enter a zone name in the cell for the target zone  
number.  
2
Enter an area name in the cell for the area number 01.  
2
*
The gures under "Number" in the table means the zone  
*
Be sure to enter an area name. A site cannot be  
registered to the number 01.  
number.  
*
The gures under “Number” in the tables means the area  
or site numbers.  
Enter zone names in the cells for other numbers to  
register more zones.  
3
4
Enter area and/or site names in the cells for other  
numbers to register more areas and/or sites.  
3
Temporarily stored  
Click  
to save the current setting  
results temporarily.  
Select “Area” or “Site” from the pull-down menu of “Area/  
Site”.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
For a site, enter the IP address (global IP address of the  
target site), port number and connection password for  
the target site.  
For a site, set “Door release” to enable (ON) or disable  
(OFF) the door release action from the target site.  
Temporarily stored  
Click  
to save the current setting  
4
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
NOTES:  
Be sure to register at least one area to the area number 01.  
(“1” is entered in the cell for the area number 01 as default.)  
A call number displayed on the master station monitor consists of  
an area number plus a station number (when called from within  
your site).  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering IP units [System setting – IP  
unit registration]  
Register IP units by selecting from the connected ones to the  
system.  
*
To register a PC master station, rst install the application  
(IS-SOFT) to a PC, then connect the PC to the network and  
then start IS-SOFT.  
Click IP unit registration in the table of contents.  
1
IP unit search  
Click  
.
2
All the IP units connected to the system are displayed in  
the [Search result] on the lower side of the window.  
*
If IP units are not displayed, repeat this step until  
displayed.  
Check the boxes for the IP units you want to register,  
3
4
Add to the imported IP units list  
and then click  
.
The checked IP units are registered and displayed in  
[Imported IP units list] on the upper side of the window.  
Enter data or change settings for the registered IP  
units as needed.  
*
For "Port number", the sequential numbers are  
automatically assigned as needed. (You can also enter  
port numbers manually.)  
*
Do not use port numbers that overlap those of other  
devices connected to the same network.  
Port number auto-setting  
:
Click this to assign sequential port numbers  
automatically.  
Port forwarding setting  
:
Click this and you can conrm the port forwarding  
settings to be made on the router in another window.  
*
*
If [UPnP] is set to OFF at [Network setting:  
Common], make the port forwarding setting on the  
router with the set contents in this window manually.  
Reload  
Click  
on this window to update the current  
Close  
port forward setting, and click  
window.  
to close this  
Temporarily stored  
Click  
to save the current setting  
5
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
NOTE:  
A PC master station must be also registered as an IP unit. First  
install the application (IS-SOFT) to a PC, then connect the PC to the  
network and then register it.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to select multiple stations  
Registering stations  
[System setting – Registering stations]  
Click to check the stations you will register.  
Register all the stations connected in the system, and set the  
area, station no. and station name to them.  
Click Registering stations in the table of contents.  
1
By clicking the button on the top of the list, you can  
check or cancel all the stations on the list.  
Set the area, station no. and station name to the  
target stations.  
2
*
*
*
Setting the station no. is required to register the  
station to the system.  
For a cell with the  
pull-down menu.  
mark, select the target one from the  
Temporarily stored  
Click  
to save the current setting  
Do not set stations with the same number in an area.  
3
results temporarily.  
NOTE:  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
The name of a master station displayed on its monitor in standby  
mode is up to 16 alphanumeric characters.  
Other buttons  
Connection check  
Click to conrm the connected units.  
Connected: yellowish green  
Not connected: gray  
Station type error: pink  
[Collective setting]:  
The following buttons are used to make the settings to all  
the checked stations at one time.  
*
Pressing each button opens another window.  
NOTE:  
Be sure to check all the target stations before using these  
buttons.  
Area  
Click to set the same area number to all the checked  
stations.  
Station number  
Click to assign sequential numbers to all the checked  
stations from top to bottom. The number you enter will  
be set as the rst number and will be assigned to the top  
station of the ones checked. Other checked stations will  
be numbered sequentially.  
Station name  
Click to assign the same station name and sequential  
numbers to all the checked stations from the top down.  
Enter a name only.  
Station type  
(Not available in a network direct system.)  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Making detailed settings to stations  
[System setting – Advanced station settings]  
Making detailed settings to door  
stations  
Make detailed settings for the registered stations. The settings  
can be made to a station individually, or multiple stations of the  
same type at a time. The setting items differ from the station  
type. First select a station (or stations), and then open the  
“Advanced settings” window to make the settings.  
The following setting item buttons are displayed in the  
“Advanced settings” window.  
A
B
Basic setting procedure  
Click Advanced station settings in the table of  
contents.  
*
*
Click either the button A or B to open the  
corresponding setting window, and then make the  
settings in the displayed window(s). See the detailed  
instructions for A or B below.  
Close  
the previous window.  
Click  
to close the current window and return to  
Click to check the station(s) where detailed settings are  
to be made.  
*
*
Multiple stations of the same type can be set together.  
All stations of the same type can be selected by clicking the  
corresponding button under [Select all by type].  
A
Settings on [Called stations] setting window  
Set the master station(s) in your site and/or a remote site  
that is (are) to be called from the selected station(s).  
*
Advanced settings  
The “Advanced settings” window for the selected station type  
opens.  
Up to 20 master stations in your site can be set. Or up to  
19 master stations in your site and a remote site (up to 20  
master stations are to be set at the remote site) can be set.  
Click  
.
Select the “Call priority” from the pull-down menu.  
1
2
Reference  
Click  
to open another window, then check  
Close  
Make the settings in the displayed windows.  
the target master stations, and then click  
return to the previous window.  
to  
The selected master stations are added and displayed in  
the list.  
For door stations  
The right column of this page  
* Click  
to open another window for  
Remote sites  
selecting the remote site as the target to be called from  
the selected station(s).  
For master stations  
P.22  
When you have nished making all the detailed settings:  
Temporarily stored  
Click  
results temporarily.  
to save the current setting  
*
To delete a station (or stations) and/or remote site from  
the list, check the targets in the list and click Delete .  
*
If you wish to cancel the setting results you have made, click  
a title in the table of contents or “Refresh” in the web browser  
menu.  
Repeat step 2 to add more master stations.  
3
4
Close  
Click  
to close the current window and return to  
the previous window.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
Settings on [Other] window  
Making detailed settings to master  
stations  
[Transmit volume boost at PTT]:  
Select whether to increase the press-to-talk sound  
volume transmitted to the stations (ON) or not (OFF).  
The following setting item buttons are displayed in the  
“Advanced settings” window.  
[Camera zoom image preset]:  
Select the default of camera’s Zoom/Wide function at  
calling from the 9 zoom positions and "0" (wide) from the  
pull-down menu.  
C
D
[Call acknowledge tone on/off]:  
Select whether to sound the call acknowledge tone of  
door station (ON) or not (OFF).  
*
*
Click either the button C or D to open the  
corresponding setting window, and then make the  
settings in the displayed window(s). See the detailed  
[Backlight adjustment]:  
Select the method of adjusting the backlight in the  
daytime between “Exposure +” and “Exposure –”.  
instructions for  
Close  
or  
below.  
C
D
Close  
Click  
to close the current window and return to  
the previous window.  
Click this to close the current window and return to the  
previous window.  
About the priority  
The order of priority for actions (communication, calling, paging,  
monitoring, etc.) is as follows depending on the priority setting.  
C
Settings on [Stations to be scan monitored]  
window  
Set the scan-monitoring target sub station(s).  
Priority  
1 (high)  
2
Setting  
Action  
*
Up to 20 sub stations in your site can be set.  
[Urgent], [Broadcast] Communication, calling,  
paging  
[Priority]  
[Normal]  
-
3
Reference  
Click  
to open another window, then select  
1
4 (low)  
Monitoring, scan-monitoring  
Close  
the target stations, and then click  
the previous window.  
to return to  
The selected stations are added and displayed in the  
list.  
*
To delete a station (or stations) from the list, check the  
Delete  
target station(s) in the list and click  
.
Repeat step 1 to register more stations.  
2
3
Close  
Click  
to close the current window and return to  
the previous window.  
D
Settings on [Other] window  
[Master station function: paging, chime, monitor,  
door release, and remote site call]:  
Select whether to enable the following functions of  
master station (ON) or not (OFF).  
Starting paging  
Starting chime paging (Not available)  
Monitoring/scan-monitoring  
Releasing door  
Remote site call  
Close  
Click this to close the current window and return to the  
previous window.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Registering stations to zones  
System setting – Zone setting]  
Registering daily transfer schedule  
[Transfer setting – Registering daily  
transfer schedule]  
[
Assign stations to the registered zones.  
You can set the schedule for transferring calls to other  
master stations in your site or remote sites automatically. The  
schedules registered on this setting are used when making a  
transfer setting on a master station.  
Click Zone setting in the table of contents.  
1
Up to 2 daily schedules can be registered.  
Click Registering daily transfer schedule in the  
table of contents.  
1
Select a zone from the pull-down menu.  
2
[Schedule number]:  
Select the schedule number DT1 or DT2 from the  
pull-down menu.  
2
Reference  
Click  
to display all the registered stations  
3
4
in your site.  
Another window opens and the registered stations are  
displayed in the list.  
[Schedule name]:  
Enter the name of daily schedule.  
3
Check to select the target stations.  
[Call transfer time]:  
Set the [Start time (hour and minute)] and [End time  
(hour and minute)] of transferring.  
4
Temporarily stored  
Click  
to save the current setting  
5
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
Select stations in the following ways.  
Select stations by checking one by one.  
All stations of the same type can be selected by  
clicking the corresponding button under [Select all by  
type].  
By clicking the button on the top of the list, all the  
stations are checked or canceled.  
Close  
Click  
after you have nished selecting the  
5
6
stations.  
In the previous window, the selection results are displayed  
in the list.  
*
When canceling a registered station, check the station in  
the list, then click Delete .  
Temporarily stored  
Click  
to save the current setting  
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E
Settings on [Weekly schedule] setting window  
Setting transfer schedule  
[Transfer setting – Transfer schedule setting]  
1) Select either [Every week] or [Every other week].  
2) Set the schedule start and end dates.  
You can set a weekly transfer schedule and individual daily  
schedule.  
*
The monthly calendar is displayed by clicking  
Refer calendar and you can select the start and  
end dates.  
*
The settings can be made 1 year ahead.  
Click Transfer schedule setting in the table of  
contents.  
*
If necessary, you can change the month by clicking  
1
or  
.
3) Set one of the registered daily transfer schedules or no  
schedule to each day of the week. (Select one from the  
pull-down menu.)  
Weekly schedule  
Make the settings by clicking  
Individual schedule  
and  
corresponding window.  
2
respectively to open the  
F
E
F
Settings on [Individual schedule] setting window  
Set an individual schedule to the target date.  
*
[Individual schedule] setting window will not open if you  
have not selected the target date on the calendar in the  
[Transfer schedule setting] window.  
Individual schedule  
*
should be clicked after the target  
date is clicked on the calendar.  
or  
1) If necessary, you can change the date by clicking  
Make the settings in the displayed window(s).  
repeatedly.  
3
4
2) [Daily transfer schedule]:  
Select either of the registered daily schedules (DT1 or  
DT2) or no schedule from the pull-down menu.  
E
F
See the detailed instructions for  
right column of this page.  
or  
on the  
3) [Call transfer time]:  
When “DT1” or “DT2” is selected:  
The call transfer time is automatically entered.  
If necessary, change the [Start time (hour and  
minute)] and [End time (hour and minute)] of  
transferring manually.  
After the setting is nished on the corresponding  
Close  
window, click  
to close the window.  
Calendar and setting status can be checked for the  
selected month.  
When no schedule is selected:  
Enter the call transfer time manually.  
The registered daily transfer schedules are  
identied by colors and shown on the calendar.  
*
When the time is entered or changed manually, [Daily  
transfer schedule] changes to “Individual schedule”.  
Temporarily stored  
Click  
to save the current setting  
5
6
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
When the settings on this window have nished, update  
the system from [Updating the system]. (P. 28)  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting the timer [Timer setting]  
Set the time for each operation.  
Click Timer setting in the table of contents.  
1
Set the time for the following operations respectively.  
2
*
The setting range is displayed on the right side of each  
input box.  
[Call]:  
Set the duration of call from door stations to [Normal],  
[Priority] or [Urgent].  
[Communication]:  
Set the duration of communication between stations in  
the system including between remote sites [Via IP].  
*
[In Local] and [Telephone]: Not available in a network  
direct system.  
[Paging]:  
Set the duration of paging.  
[Monitor]:  
Set the duration of monitoring only one station.  
[Scan monitor: Switching]:  
Set the duration of monitoring each station while scan-  
monitoring.  
NOTE:  
The actual duration slightly differs from the setting value.  
[Contact output]:  
(Not available)  
[Door release]:  
Set the duration of door release.  
*
If you set the time to “0”, the door is released while  
the door release button on the master station is held  
down.  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
G
Settings on [Remote site master call] setting  
window  
You can set a station (master station or door station) that  
receives a call from a master station in a remote site. One  
station can be set for each priority.  
Setting stations to receive calls and  
zones to receive paging from remote sites  
[Remote site pilot call setting]  
Set the master stations and sub stations to receive calls, and  
zones to receive paging from remote sites.  
Reference  
Click  
for “Normal”.  
1)  
All the registered stations are displayed in the list in  
another window.  
*
The setting can be made for each priority individually.  
2) Check the box for the target station in the list, and then  
Click Remote site pilot call setting in the table of  
contents.  
Close  
1
click  
.
The current window closes and the set station is  
displayed in the [Remote site master call] setting  
window.  
To delete a set station  
Delete  
Click  
*
for "Normal".  
Advanced settings  
for  
respectively to open the  
Make the setting by clicking  
Selecting another station also overwrites the previous  
one.  
2
G
H
I
the setting items  
,
,
corresponding window.  
Make the setting for “Priority” and “Urgent” in the same way.  
Settings on [Remote site door call] setting  
window  
H
G
H
*1  
I
You can set up to 20 master stations that receive a call  
from a door station in a remote site. Up to 20 master  
stations can be set for each priority.  
Reference  
Click  
for “Normal”.  
1)  
All the registered master stations are displayed in the  
list in another window.  
*2  
2) Check the boxes for the target master stations in the  
Close  
list, and then click  
.
The current window closes and the set stations are  
displayed in the [Remote site door call] setting window.  
Make the setting in the displayed window(s).  
3
To delete a set station  
Delete  
Check the box for the target station and click  
.
G
H
I
See the detailed instructions for  
right column of this page.  
on the  
,
,
*
You can also select two or more stations and delete  
them at a time.  
Make the setting for “Priority” and “Urgent” in the same  
way.  
After the setting is nished on the corresponding  
4
5
Close  
window, click  
to close the window.  
I
Settings on [Remote site paging] setting window  
You can set a zone that receives paging from a remote  
site. One zone can be set for each priority.  
Temporarily stored  
Click  
results temporarily.  
to save the current setting  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
1) Select the target zone from the pull-down menu for  
“Normal”.  
*
Make the setting for “Priority”,“Urgent”and “Broadcast”  
in the same way.  
*1: The settings on this item are available for a call from the  
standard (IP) system in a remote site. The setting method is  
H
the same as the item . (Refer to the “SETTING MANUAL”  
for a standard (IP) system for details.)  
*2: Not available  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Video setting  
Setting time and date  
[Time and date setting]  
Click Video setting in the table of contents.  
Set the following settings for video quality.  
1
2
Set the time and date of the system, used for transfer schedule.  
Click Time and date setting in the table of contents.  
1
[Frame Rate]:  
Set the frame rate selecting “1”, “2”, “5”, “7.5”, “10” or “15”  
fps from the pull-down menu.  
[Quality]:  
Set the following settings.  
Set the video quality selecting “Low”, “Middle”, “High” or  
“Excellent” from the pull-down menu.  
2
Required  
[Set current time]  
:
Temporarily stored  
Click  
to save the current setting  
Set the current time and date in one of the following  
methods.  
3
results temporarily.  
Input the current time and date manually, and then  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
Manual setting  
click  
.
Synchronized with PC  
Click  
to set the current time  
and date by making it synchronized with the PC.  
NOTE:  
You can also set the current time and date by making it  
synchronized with NTP server [Synchronized with NTP  
server] as shown below.  
Raising [Frame Rate] from 1 to 15 fps gives you a smoother image  
quality. Also, raising [Quality] gives you a finer image. However, if  
both [Frame Rate] and [Quality] are raised at the same time, a large  
amount of network bandwidth will be required.  
*
If there is no power supply to the system for a long  
time because of power failure etc., the time and date  
setting may be cleared.  
[NTP (Network Time Protocol)]:  
Set [Synchronized with NTP server] to ON to set the  
current time and date by making it synchronized with  
NTP server. Then set the [NTP server] and [NTP port  
number].  
*
[NTP server]:  
Enter the IP address or domain name of the NTP  
server to be used as the master clock.  
[UTC time zone]:  
Set the time differences from Coordinated Universal  
Time (UTC). Set the [Hour difference] and [Minute  
difference] respectively.  
[Synchronize interval]:  
When [Synchronized with NTP server] is set to ON, the  
current time and date are set by being synchronized  
with the NTP server with the entered time interval.  
[Daylight savings time]:  
Set whether to utilize daylight savings time (ON) or  
(OFF). When set to ON, then set the start and end  
times (Month, Week of the month, Day of the week,  
Hour and Minute), and time differences (Hour and  
Minute).  
*
It is recommended to connect the system with a PC or  
NTP server constantly to keep the correct time and date  
setting.  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E-mail setting  
Downloading/uploading setting data  
[Setting le]  
You can send an e-mail when calling or send error messages  
etc. by e-mail. Up to 3 mail addresses can be set.  
You can download the setting data you have made into a le  
and save it on the PC. On the contrary, you can upload the  
setting data from the PC.  
NOTES:  
Prepare an e-mail account for this function beforehand.  
Make sure to enter the system name at [Network setting:  
Individual] – [System name] to display the title with an e-mail.  
Make sure to enter primary and/or secondary DNS server  
information at [Network setting: Individual] to all the IP units.  
*
It is recommended to download the setting data as a backup  
copy after you nish making settings or setting changes.  
When downloading setting data onto the PC  
Click Downloading setting data in the table of  
contents.  
Click E-mail setting in the table of contents.  
1
1
2
Set the following settings.  
[Email destination address]:  
Enter up to 3 mail addresses (destination addresses).  
[Email source address]:  
Click  
to download the current setting data  
Download  
2
Enter the source mail address.  
into a le.  
[SMTP authentication]:  
Congure SMTP authentication as required by source  
E-mail provider.  
When uploading setting data  
Click Uploading setting data in the table of contents.  
1
[Language selection]:  
Set the language you want to use for entering the system  
name.  
*
You can use English only for the body of the message.  
[Mailing event]:  
Click  
to the system.  
You can select the setting data le from another window,  
and upload it.  
to upload the setting data from the PC  
Upload  
2
3
Select mailing events by setting the target ones to [ON].  
Temporarily stored  
Click  
to save the current setting  
3
results temporarily.  
*
If you wish to cancel the setting results you have made,  
click a title in the table of contents or “Refresh” in the  
web browser menu.  
Update the system.  
*
Refer to “Updating the system” below.  
NOTE:  
Uploading the setting data will overwrite the current data.  
Updating the system  
[Updating the system]  
Update the system with the setting data you have entered  
(currently stored temporarily).  
Click Updating the system in the table of contents.  
1
Click  
to update the system with the setting  
Update  
2
data currently stored temporarily.  
NOTE:  
Do not turn off the system while updating the system.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
This section describes the use of functions for the system maintenance. These functions are available on the web server.  
Initializing the system [Initialization]  
Updating the rmware [Firmware update]  
Downloading updated rmware data  
You can reset the system settings to factory default.  
Please access our web page at http://www.aiphone.net/ and  
download the rmware data on the PC to update the system.  
For the download procedure, see the instructions on our web  
page.  
Access the web browser and log in.  
(P. 14)  
1
Click Initialization in the table of contents.  
2
Access the web browser and log in. (P. 14)  
1
Click Firmware update in the table of contents.  
2
Click  
.
Initialization  
3
Downloading system log [System log]  
Click  
.
Update  
3
Another window opens.  
You can acquire the system operation log.  
Click  
and select the target rmware.  
Browse...  
Access the web browser and log in.  
(P. 14)  
4
5
1
When the rmware is displayed in the window, click  
Upload  
Click System log in the table of contents.  
.
2
When “Update rmware.” is displayed, the update process  
is complete.  
NOTES:  
If the power is turned off while it is writing, the product will  
malfunction.  
Click  
to acquire the log from the system.  
Download  
3
4
The system may not operate normally while updating the  
firmware.  
Conrm the log, and save it as needed.  
NOTE:  
NOTE:  
If the update fails, try again.  
The log is overwritten constantly from the oldest records.  
Referring to the troubleshooting guide  
[Troubleshooting]  
Click Troubleshooting in the table of contents.  
1
The following information appears in the window.  
Information about the online-help that you can refer to  
when trouble occurs in setting the system  
Supported characters and symbols  
Registering your system [Registration]  
Click Registration in the table of contents.  
1
2
Register  
Click  
to open the registration window, and  
then register your system on the window.  
*
If you use an IS-SOFT in the system, enter the license  
key of the IS-SOFT.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Setting Information Memo  
Record your settings information. It will need when resetting or maintenance.  
Host unit  
Network setting: Individual  
Static IP Address  
Default Gateway  
Primary DNS Server  
MAC address  
Subnet Mask  
Secondary DNS Server  
Unit name  
Connection port  
Network setting: Common  
Global IP address  
Connection port: global  
Multicast address 1:  
3:  
Connection Password  
2:  
4:  
5:  
Audio/video port  
Administrator setting  
ID  
Password  
IP Address  
Client unit  
Network setting: Individual / Administrator setting  
#
1
Unit name  
MAC address  
ID  
Password  
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
* Download and save the setting data on the PC. Refer to [Setting le] for details.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AIPHONE CO., LTD., NAGOYA, JAPAN  
AIPHONE CORPORATION, BELLEVUE, WA, USA  
AIPHONE S.A.S., LISSES-EVRY, FRANCE  
Download from Www.Somanuals.com. All Manuals Search And Download.  

3Com Switch WX1200 User Manual
Aga Ranges Stove Berrington User Manual
Air King Stove 4TM64A 9515A User Manual
Altec Lansing Portable Speaker 403A User Manual
Apple Network Card QuickTime Streaming Server Darwin Streaming Server User Manual
Audiovox Remote Starter APS 700 User Manual
Avocent Switch 590 222 501M User Manual
Bakers Pride Oven Oven CO11 G1 User Manual
BB Electronics Network Card DTB Series User Manual
Behringer Karaoke Machine mix800 User Manual