FK1629 B 0811YZ
IS SERIES
Commercial & Security IP Video Intercom system
Network Direct System
SETTING MANUAL
Thank you for selecting Aiphone for your communication and security needs. Please read this manual and the separate
“OPERATION MANUAL” carefully before setting and using this system.
*
Refer to the provided “INSTALLATION MANUAL” for complete information regarding this system.
IMPORTANT
Please read and understand the system setting procedures before beginning the setup process.
Please note that images and illustrations depicted in this manual may differ from the actual ones.
Download from Www.Somanuals.com. All Manuals Search And Download.
ABOUT THIS MANUAL
The IS system provides various manuals to meet various system planning and work processes. Use the manuals necessary for your
system.
Manual configurations
The following manuals are provided for a network direct system. Read all the manuals for installing, setting up, and using a network
direct system, or provide the manuals to the persons working with the system.
INSTALLATION MANUAL (A booklet included with the IP master station (IS-IPMV))
Used for installing and connecting IP master stations and IP video door stations. (For an installer or serviceman)
SETTING MANUAL (This manual on the CD-ROM included with the IP master station (IS-IPMV))
This manual describes how to make the system settings and system maintenance. (For an installer or serviceman)
OPERATION MANUAL (An electronic manual on the CD-ROM included with the IP master station (IS-IPMV))
Information for using the system for calling, communicating, paging, monitoring, etc. (For users of the system)
Note the following:
•
•
•
This manual describes how to make the system settings for a network direct system (without an IP control unit) only. For a standard
(IP) system (including one or more IP control units), refer to the “SETTING MANUAL” for the standard (IP) system.
Master stations and door stations that can be used in a network direct system are IP units (IS-IPMV, IS-IPDV, IS-IPDVF and IS-
SOFT) only.
PC master stations (IS-SOFT) can also be used in a network direct system. For setting a PC master stations (IS-SOFT), refer to
the “SETTING MANUAL” for the PC master station (IS-SOFT).
PURPOSE OF THE SYSTEM SETTINGS
Configure the system settings based on how your system is planned to be used. System settings must be completed before the
system will operate.
CAUTION:
Make the settings correctly. If the settings are not made correctly, the system will not function as planned.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTING LIST
The following is the list of system settings you can make via the web browser. The titles or items in shaded cells are required.
NOTES:
•
•
•
The following list is a brief overview of the setting items available in the system settings on a PC. The descriptions, and the style and order of
descriptions do not necessarily equate with the actual displays.
The following list describes the setting contents required only for a network direct system. The actual setting windows of the web browser also
includes contents not described in the list.
Make a note of the setting results you have made by using the “Setting Information Memo” ( P. 30) etc. in case of unexpected data erasure, and
→
keep it in a safe place not to lose it.
Title
Sub title
Item
(Language)
Sub item
Setting range
English/French/German/Spanish/Dutch/ English
Italian/Japanese
Default
-
-
-
Network setting Network setting:
Individual
IP version
Host unit setting
-
-
IPv4
IPv4
Client unit
-
Host unit/Client unit
Host unit IP address (available (Enter the Host unit IP address.)
when [Host unit setting] is set to
“Client unit”)
System name
-
Up to 24 alphanumeric characters
-
(available when [Host
unit setting] is set to
“Host unit”)
(Select the network
setting method.)
-
DHCP/Static IP Address
DHCP
Static IP Address
Static IP Address (required when 0 – 255 (for each field)
[Static IP Address] is selected)
192.168.0.40
255.255.255.0
Subnet Mask (required when
[Static IP Address] is selected)
0 – 255 (for each field)
Default Gateway
Primary DNS Server
Secondary DNS Server
-
-
0 – 255 (for each field)
0 – 255 (for each field)
0 – 255 (for each field)
(Unmodifiable)
Up to 24 alphanumeric characters
(except accent marks, umlaut marks,
etc.)
-
-
-
MAC address
Unit name
(Unmodifiable)
-
Web port
Connection port
Connection
Password
-
-
-
(Unmodifiable)
1024 - 65535
Up to 16 alphanumeric characters
(Unmodifiable)
5060
aiphone
Network setting:
Common
UPnP
Global IP address
(available when
-
-
ON/OFF
0 - 255 (for each field)
ON
-
[UPnP] is set OFF)
Connection port:
global
Multicast address
1 - 5 (“Multicast
address 3” is not
available.)
-
-
(Unmodifiable)
(Unmodifiable)
239.0.0.0 - 239.255.255.255
1: 239.0.1.1
2: 239.0.1.2
4: 239.0.1.4
5: 239.0.1.5
Audio/video port
-
1024 - 65535
50800 - 50813
Administrator
setting
-
-
New administrator ID -
Up to 16 alphanumeric characters
Up to 16 alphanumeric characters
Up to 16 alphanumeric characters
Up to 16 alphanumeric characters
-
Current Password
New Password
New Password
(Re-type)
-
-
-
- (aiphone)
-
-
IP unit search
-
-
-
-
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Title
Sub title
Item
Sub item
Setting range
Default
System setting Area/Site
registration
Area/Site Name
-
Up to 24 alphanumeric characters (for
up to 99 areas including sites)
* Up to 31 for sites
1 (for Area
number 01)
Area/Site
IP Address (sites
only)
-
-
Area/Site
0 - 255 (for each field)
Area
-
Port number (sites
only)
Connection
Password (sites only)
Door release (sites
only)
-
-
-
-
-
1024 - 65535
-
Up to 16 alphanumeric characters
ON/OFF
-
ON
Zone registration Zone name
Up to 24 alphanumeric characters (for
up to 99 zones)
IP video door station, IP master station,
PC master station
-
-
IP unit registration Station type
MAC address
Unit name
Port number
Area
Station number
-
-
-
-
-
-
-
-
Up to 24 alphanumeric characters
1024 - 65535
(Area) 01 to 99
50900 - 50902
(Area) 01
-
Registering
stations
001 to 999
0001 to 9999
00001 to 99999
Station name
Station type
-
-
Up to 24 alphanumeric characters
(Unmodifiable)
-
(Unmodifiable)
Advanced station Video door station
settings
Call priority
Called stations
Normal/Priority/Urgent
(Set up to 20 targets from the registered -
ones.)
Normal
Transmit volume boost ON/OFF
OFF
at PTT
(ON: approx. +6dB up)
Camera zoom image 0 (wide)/1/2/3/4/5/6/7/8/9 (zoom)
preset
Call acknowledge tone ON/OFF
on/off
5 (Center)
ON
Backlight adjustment Exposure +/Exposure -
Exposure +
-
Master station
Stations to be scan monitored
(Select up to 20 sub stations from the
registered ones.)
Master station function: ON/OFF
ON
paging, chime, monitor,
door release, and
remote site call
Zone setting
Zone number
Stations
-
-
-
-
-
(Select from the registered ones.)
(Select from the list.)
DT1/DT2
Up to 24 alphanumeric characters
Hour: 0 to 23
-
-
Transfer setting Registering daily Schedule number
DT1
-
-
transfer schedule
Schedule name
Call transfer time
Minute: 0 to 59
(Set to the Start time and End time
individually.)
Transfer schedule Weekly schedule
setting
(Repeat setting)
Every week/Every other week
From the current day to 1 year ahead
From the start day to 1 year ahead
None/DT1/DT2 (for each day of the
week)
Every week
-
-
Schedule start date
Schedule end date
(Transfer schedule)
None
Individual schedule (Date)
From the current day to 1 year ahead
(Select from the registered ones.)
Hour: 0 to 23
-
Daily transfer schedule
Call transfer time
None
-
Minute: 0 to 59
(Set to the Start time and End time
individually.)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Title
Sub title
Item
Sub item
Setting range
Default
Timer setting
-
Call
Normal/Priority/Urgent
10 to 600 (sec.), 0 (Unlimited)
Normal: 30 (sec.)
Priority: 90 (sec.)
Urgent: 0
(Unlimited)
Communication
In Local (Not available)
30 to 600 (sec.) (Not used for network
direct system)
60 (sec.)
Via IP
30 to 600 (sec.)
60 (sec.)
Telephone (Not available)
30 to 600 (sec.) (Not used for network
direct system)
120 (sec.)
Paging
Monitor
Scan monitor:
Switching
-
-
-
30 to 600 (sec.)
10 to 600 (sec.)
5 to 60 (sec.)
60 (sec.)
60 (sec.)
7 (sec.)
Contact output
(Not available)
External sound source 1
External sound source 2
-
10 to 300 (sec.)
10 to 300 (sec.)
0 to 300 (sec.), (0: Released while
30 (sec.)
30 (sec.)
10 (sec.)
Door release
holding the Door release button pressed.)
Remote site
pilot call setting
-
Remote site master Normal/Priority/Urgent
call
(Select one from the registered stations
in your site for each of “Normal”, “Priority”
and “Urgent”.)
(Select up to 20 stations from the
registered master stations in your site for
each of “Normal”, “Priority” and “Urgent”.)
(Select up to 20 stations from the
registered master stations in your site for
each of “Normal”, “Priority” and “Urgent”.)
-
-
-
Remote site door call Normal/Priority/Urgent
Remote site room
sub call (available
when the remote site
is a standard (IP)
system that includes
room sub stations
(IS-RS).)
Normal/Priority/Urgent
Remote site paging Normal/Priority/Urgent/
Broadcast
(Select one from the registered zones in -
your site for each of “Normal”, “Priority”,
“Urgent” and “Broadcast”.)
Video setting
-
-
Frame Rate
Quality
Set current time
-
-
1/2/5/7.5/10/15 (fps)
Low, Middle, High, Excellent
Year: 2009 to 2099
Month: 1 to 12
Day: 1 to 31
15 (fps)
Excellent
(Internal time
of the IP Host
unit)
Time and date
setting
Manual setting
Hour: 0 to 23
Minute: 0 to 59
Second: 0 to 59
Synchronized with PC
-
-
NTP
Synchronized with NTP server ON/OFF
OFF
-
123
0
NTP server*1
IP address or domain name
1 to 65535
-12 to +13 (h)
NTP port number*1
(UTC time zone*1)
Hour difference*1
(UTC time zone*1)
-45/-30/0/+30/+45 (m)
0
Minute difference*1
Synchronize interval
Starts*2 Month
1 to 240 (h)
ON/OFF
JAN to DEC (M)
1st to 4th (W)/The last
Sunday to Saturday
0 to 23 (h)
24 (h)
OFF
JAN
1st
Sunday
-
-
JAN
1st
Sunday
-
-
1
0
Daylight savings time -
Day
(Week)
(Day)
Hour
(Hour)
(Minute)
0 to 59 (m)
Ends*2 Month
Day
JAN to DEC (M)
1st to 4th (W)/The last
Sunday to Saturday
0 to 23 (h)
0 to 59 (m)
0 to 12 (h)
(Week)
(Day)
Hour
(Hour)
(Minute)
Hour difference*2
Minute difference*2
0/30/45 (m)
*1: Available only when [Synchronized with NTP server] is set to ON.
*2: Available only when [Daylight savings time] is set to ON.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Title
Sub title
Item
Sub item
Setting range
Default
E-mail setting
-
Email destination
address
Email source
address
1/2/3
-
Up to 256 alphanumeric characters
-
-
Up to 256 alphanumeric characters
SMTP authentication SMTP server
SMTP server port
Up to 256 alphanumeric characters
1 to 65535
-
465
(Email) login ID
Password
-
Up to 256 alphanumeric characters
Up to 64 alphanumeric characters
English/French/German/Spanish/Dutch/ English
Italian/Japanese
-
-
Language selection
Mailing event
Call: Normal
Call: Priority
Call: Urgent
System start
Data communication error in the ON/OFF
system
ON/OFF
ON/OFF
ON/OFF
ON/OFF
OFF
OFF
OFF
OFF
OFF
Setting file
Downloading
setting data
Uploading setting
data
-
-
-
-
-
-
-
-
7
Download from Www.Somanuals.com. All Manuals Search And Download.
SYSTEM SETTING FLOW
First of all, make the network settings. The network setting method differs according to the network environment. Select the flow
suitable for your network environment from the chart below, and start the network settings after you fully understand it. After the
network settings are finished, make the other individual system settings. See P. 15-28 for the system setting details.
NOTE:
The system settings should be made mainly on the IP host unit in the system (in a site). You select one as the IP host unit among the IP units
connected to the system and others as the IP client units. (A PC master station (IS-SOFT) cannot be used as the IP host unit.)
First select the Flow 1 , Flow 2 or Flow 3 from the chart below, then start the network settings by
following the selected flow.
START
Do you communicate with remote sites (calling, call transferring,
paging, etc.)?
YES
NO
(*4)
(*3)
NO
NO
Do you use a router on which UPnP functions,
and does UPnP function normally?
(*1)
YES
Do you have a DHCP server (or router that
has a DHCP server function) in the network,
and does it have an automatic IP address-
assigning function?
Do you have a DHCP server (or router that
has a DHCP server function) in the network,
and does it have an automatic IP address-
assigning function?
YES
NO
(*3)
YES
(*2)
Flow 1
Flow 2
(IP host unit: A static IP address is set,
(All units: Static IP addresses are set)
IP client units: IP addresses are assigned by the DHCP
server automatically)
Go to P. 10.
Go to P. 9.
NOTE:
If you connect a PC master station (IS-SOFT) to the network, install the software (IS-SOFT) to a PC before connecting it to the network.
(*1): UPnP may not function normally depending on the router. Refer to [System log]→[UPnP operation check result] (→P. 29) on the
IP host unit. If the [System log] window shows that UPnP is not functioning normally, the UPnP function of the router cannot be
used with this system. In that case, set [UPnP] to OFF at [Network setting: Common] (→P. 16) and then make settings on the
router again by confirming the settings at [IP unit registration] (→P. 19). See http://www.aiphone.net/ for the router to which the
operartion check has finished and setting examples.
(*2): If the DHCP server (or router that has a DHCP server function) has a function to assign a static IP address to a specified MAC
address, you can make the DHCP server assign the IP addresses to all the IP units automatically.
(→
(All units: IP addresses are assigned by the DHCP server automatically) (P. 11))
Flow 3
(*3): Set [UPnP] to ON at [Network setting: Common] (→P. 16) (Default: ON).
(*4): Set [UPnP] to OFF at [Network setting: Common] (→P. 16) (Default: ON).
If you communicate with remote sites (calling, call transferring, paging, etc.), make the remote site connection settings (→P. 12)
after the network settings for your site have finished.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Flow 1
(IP host unit: A static IP address is set,
IP client units: IP addresses are assigned by the DHCP server automatically)
* This is the outline of setting flow. Also make the detailed settings on each setting window referring to the corresponding pages.
START
: Settings on the IP host unit
Write down the MAC addresses of all the IP units to be used
in the system in advance by using the “Setting Information
Memo” (→P. 30) etc.
: Settings on the IP client units
*
The MAC address is labeled on each unit.
(When making the IP host unit settings
after connecting the units to the network)
Decide the static IP address for the IP unit to be used as the
IP host unit.
*
Use an address out of the range of DHCP assignment for the IP host
unit in order to prevent the address for the IP host unit being assigned
to another IP client unit by an influence of the turn-on order between
the IP host unit and the router (that has a DHCP server function) etc.
(When making the IP host unit settings
before connecting the units to the network)
Connect the IP host unit and the PC used for settings
Connect the units and the PC used for settings to the
network, and then turn them on.
directly, and then turn them on. After a while, access
"https://192.168.0.40/" from the browser on the PC. (→P. 14)
NOTES:
•
•
When connecting a PC to the IP unit directly, use an Ethernet
crossover cable.
Search for the IP address of the IP host unit from the MAC
address of the IP host unit by using IS_IPSEARCH.exe (in the
CD-ROM included with the IP master station (IS-IPMV)). (If
the address does not appear, repeat this step until it appears.)
Then access the address from the browser on the PC. (→P. 14)
If a warning dialog box for security or guarding against virus
programs appears when accessing the web browser, give permission.
(Log in.)
Make the [Network setting: Individual] settings on the IP
host unit. (→ P. 16)
*
*
This address is the temporary one for the initial setting.
Set it as "Host unit".
*
Set the static IP address to the IP host unit.
(Log in.)
Make the [Network setting: Individual] settings on the IP
host unit. (→ P. 16)
Update the system at [Updating the system]. (→ P. 28)
*
Set it as "Host unit".
*
Set the static IP address to the IP host unit.
Connect the units and the PC used for settings to the
network, and then turn them on.
(IP addresses are assigned to the IP client units by the
DHCP server automatically.)
Update the system at [Updating the system]. (→ P. 28)
Search for the IP units (other than PC master stations) you
will use in the system at [IP unit search] on the IP host unit,
and open the setting window for each IP unit. (→ P. 17)
Make the [Network setting: Individual] settings on the IP
client units. (→ P. 16)
*
*
*
Set them as "Client unit" (if they are not set as "Client unit").
Enter the IP address of the IP host unit.
Select "DHCP" for acquiring IP addresses (if "DHCP" is not selected).
Add IP units you will use in the system at [IP unit
registration] on the IP host unit. (→ P. 19)
Update the system at [Updating the system]. (→ P. 28)
If you will connect your site with remote sites, make the
remote site connection settings. (→ P. 12)
Confirm the [Network setting: Common] settings on the IP
host unit. (→ P. 16)
*
Confirm that the multicast addresses and/or port numbers do not overlap those
of other manufacturer’s network devices connected to the same network.
Make the other system settings. (→ P. 17-28)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Flow 2
(All units: Static IP addresses are set)
* This is the outline of setting flow. Also make the detailed settings on each setting window referring to the corresponding pages.
START
: Settings on the IP host unit
Write down the MAC addresses of all the IP units to be
used in the system in advance by using the “Setting
Information Memo” (→P. 30) etc.
: Settings on the IP client units
*
The MAC address is labeled on each unit.
For the IP host unit
Decide the static IP address for each IP unit.
Connect the IP host unit and the PC used for settings
directly, and then turn them on. After a while, access
"https://192.168.0.40/" from the browser on the PC.
(→P. 14)
Make the [Network setting: Individual] settings on each
IP unit individually. (→ P. 16)
NOTES:
•
When connecting a PC to the IP unit directly, use an
Ethernet crossover cable.
If a warning dialog box for security or guarding against virus
programs appears when accessing the web browser, give permission.
Connect the units and the PC used for settings to the
network, and then turn them on respectively.
•
(Log in.)
Confirm the [Network setting: Common] settings on the
IP host unit. (→ P. 16)
Make the [Network setting: Individual] settings on the
IP host unit. (→ P. 16)
*
Confirm that the multicast addresses and/or port
numbers do not overlap those of other manufacturer’s
network devices connected to the same network.
*
*
Set it as "Host unit".
Set the static IP address to the IP host unit.
Update the system at [Updating the system]. (→ P. 28)
Add IP units you will use in the system at [IP unit
registration] on the IP host unit. (→ P. 19)
(The selected unit is added in the list whenever selected.)
For each IP client unit
If you will connect your site with remote sites, make the
remote site connection settings. (→ P. 12)
Connect an IP client unit and the PC used for settings
directly, and then turn them on. After a while, access
"https://192.168.0.40/" from the browser on the PC.
(→P. 14)
NOTES:
•
Make the other system settings. (→ P. 17-28)
When connecting a PC to the IP unit directly, use an
Ethernet crossover cable.
If a warning dialog box for security or guarding against virus
programs appears when accessing the web browser, give permission.
•
(Log in.)
Make the [Network setting: Individual] settings on the
IP client unit. (→ P. 16)
*
Set it as "Client unit".
*
*
Enter the IP address of the IP host unit.
Set the static IP address to the IP client unit.
Update the system at [Updating the system]. (→ P. 28)
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Flow 3
(All units: IP addresses are assigned by the DHCP server automatically)
* This is the outline of setting flow. Also make the detailed settings on each setting window referring to the corresponding pages.
START
: Settings on the IP host unit
Write down the MAC addresses of all the IP units to be used
in the system in advance by using the “Setting Information
Memo” (→P. 30) etc.
: Settings on the IP client units
*
The MAC address is labeled on each unit.
Set the router (or DHCP server) so that it assigns a static IP
address to the IP unit to be used as the IP host unit.
Connect the units and the PC used for settings to the
network, and then turn them on.
Access the IP address assigned to the IP host unit from the
browser on the PC. (→P. 14)
(Log in.)
Make the [Network setting: Individual] settings on the IP
host unit. (→ P. 16)
*
*
Set it as "Host unit".
Select "DHCP" for acquiring an IP address.
Update the system at [Updating the system]. (→ P. 28)
Confirm the [Network setting: Common] settings on the IP
host unit. (→ P. 16)
Search for the IP units (other than PC master stations) you
will use in the system at [IP unit search] on the IP host unit,
and open the setting window for each IP unit. (→ P. 17)
*
Confirm that the multicast addresses and/or port numbers
do not overlap those of other manufacturer’s network
devices connected to the same network.
Add IP units you will use in the system at [IP unit
registration] on the IP host unit. (→ P. 19)
Make the [Network setting: Individual] settings on the IP
client units respectively. (→ P. 16)
*
Set them as "Client unit" (if they are not set as "Client unit").
*
*
Enter the IP address of the IP host unit.
Select "DHCP" for acquiring IP addresses (if "DHCP" is not
selected).
If you will connect your site with remote sites, make the
remote site connection settings. (→ P. 12)
Update the system at [Updating the system]. (→ P. 28)
Make the other system settings. (→ P. 17-28)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote site connection settings
You need to make the remote site connection settings to enable communication between your site and remote sites. Make the settings
by following the procedure below after the network settings for your site have finished.
* This is the outline of setting flow. Also make the detailed settings on each setting window referring to the corresponding pages.
Procedure
: Settings on the IP host unit
Complete the network settings for your site by following
: Required when [UPnP] is set
to OFF at [Network setting:
Common] (→ P. 16)
. (→P. 9-11)
Flow 1 , Flow 2 or Flow 3
Get the following information for the remote sites you will
connect with your site.
"Global IP address"
"Connection port: global"
"Connection Password"
Set the following setting items on the IP host unit. (→ P. 16)
[Network setting: Individual] :
"Default Gateway"
[Network setting: Common] :
"UPnP"
"Global IP address"
"Audio/video port"
Make the [Area/Site registration] on the IP host unit. (→ P. 18)
* Select "Site" with the "Area/Site" pull-down menu and enter
the information of the site you will connect.
Update the system at [Updating the system]. (→ P. 28)
Open the [IP unit registration] window on the IP host unit,
Port forwarding setting
and then click the
button. (→ P. 19)
*
Another window opens and the port forwarding setting
contents are displayed.
Set the router with the port forwarding setting contents you
confirmed in the previous step.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
STARTING UP THE SYSTEM AND PREPARING FOR THE SETTINGS
The system settings are mainly made on the PC by accessing the web browser for the settings incorporated with the IP unit as the IP
host unit. It is recommended to use only one PC for the settings that is connected to the system.
System requirements for PC
Your PC and operating environment must meet the following system requirements to make the settings.
Network
10BASE-T Ethernet, 100BASE-TX Ethernet
Web browser
Internet Explorer 6.0 or later (with Internet Options SSL 3.0 enabled)
Starting up the system
Connect a PC to the IP unit.
[When connecting a PC to the IP unit directly]
1
[When connecting a PC to the IP unit via a hub
(switch)]
IP master station
(IS-IPMV)
IP video door station
(IS-IPDV or IS-IPDVF)
IP master station
(IS-IPMV)
IP video door station
(IS-IPDV or IS-IPDVF)
or
or
LAN/PoE
LAN/PoE
RJ45
PC
RJ45
CAT5e/6 (Crossover cable)
RJ45
100m (330')
10BASE-T/100BASE-TX
CAT5e/6
(Straight-through cable)
100m (330')
10BASE-T/
100BASE-TX
NOTES:
•
RJ45
RJ45
Hub
(Switch)
When connecting a PC to the IP unit directly, use an Ethernet
crossover cable.
•
The IP address of IP unit is set to (192.168.0.40) and Subnet
Mask is set to (255.255.255.0) as default. Change the IP
address of your PC if needed.
CAT5e/6
(Straight-through
cable)
100m (330')
10BASE-T/
100BASE-TX
RJ45
(Continued on next page)
PC
NOTES:
•
Be sure to connect the CAT5e/6 cable to the LAN ports of both
units.
•
The IP address of IP unit is set to (192.168.0.40) and Subnet
Mask is set to (255.255.255.0) as default. Change the IP
address of your PC if needed.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Turn on the power to the IP unit.
2
*
If the unit is connected to a switch or injector that has
a PoE function, the power is being supplied. If a power
supply unit is connected to the unit, turn on the power of
the power supply unit.
*
*
Turn on all the units constituting the system depending
on the network setting method.
The status LED of an IP video door station changes from
red lighting to orange blinking.
(When the settings have correctly made, it changes to
orange lighting.)
The status LED of an IP master station changes from red
lighting to red blinking.
(When the settings have correctly made, it turns off.)
Start up the PC, and then open the browser window.
3
4
Enter the (static) IP address assigned to the IP unit
to access the web browser for settings.
192.168.0.40/
English
After selecting
as the target language, the login
window of the web browser is displayed.
Log in to the system by setting the following items.
5
ID
•
•
•
Enter “aiphone”.
Password
Enter “aiphone”.
Login
Login
Click
to display the setting window.
*
When you log in for the first time, the [Registration]
window appears. Register your system as needed.
(When registering your system, if you use an IS-SOFT in
the system, enter the license key of the IS-SOFT.)
NOTE:
Be sure not to log in to the system more than once at the same
time by opening multiple browser windows on the PC.
Go to the next page.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
THE SYSTEM SETTING DETAILS
The basic setting procedure
When you have logged in to the system, the setting window appears. You can make the settings on this window.
*
*
Make sure to refer to the on-screen instructions and comments displayed on each window when you make the settings.
Depending on the PC and its OS or environment, the display may differ.
<Setting window example>
Setting contents display area
The setting items of the selected setting title and their
details are displayed here.
Table of contents
Instructions area
The instructions for settings are
displayed here.
Temporarily stored
The setting titles are listed here.
Click the title on which you want
to make the settings to display the
corresponding setting window.
Click this to save the current setting results
temporarily.
* This temporary storing will not update the
system with the new setting results. To update
the system, click the title “Updating the system”
and follow the necessary procedure.
NOTE:
The setting titles not required for a
network direct system are also grayed
out.
The setting procedure
Click a title in the table of contents on which you wish to make the settings.
The setting window of the title is displayed.
1
Make the settings on the setting items individually.
2
3
Temporarily stored
When you have finished making the settings on the current window, click
results temporarily.
to save the setting
*
If you wish to cancel the setting results you have made, click a title in the table of contents or “Refresh” in the web browser
menu. (If you change the current window to another without storing the setting results temporarily, a pop-up window appears
asking if you want to store the results temporarily or not.)
Repeat step 1 to 3 to make the settings on the other titles.
To log out of the system, click [Logout] in the table of contents.
4
*
15
Download from Www.Somanuals.com. All Manuals Search And Download.
The following shows the setting procedure for the items of each title.
Refer to “SETTING LIST” (→P. 4-7) for details about the settings. Make the settings by also referring to the on-screen instructions.
Making network settings to each IP unit
[Network setting: Individual]
When the settings on this window have finished, update
the system from [Updating the system]. (→P. 28)
4
Make the settings for network to each IP unit connected
to the system according to your requirements.
Making network settings for the whole
system [Network setting: Common]
Click Network setting: Individual in the table of
contents.
1
Make the network settings for the whole system on the
web browser of the IP host unit.
Click Network setting: Common in the table of
contents.
1
Make the settings on the following items displayed in
the setting window.
2
[Host unit setting]:
•
Set this unit as either “Host unit” or “Client unit”. When set to
“Client unit”, also enter the IP address of the IP host unit.
[System name]:
Required
•
Make the settings on the following items displayed in
the setting window.
2
When “Host unit” is selected at [Host unit setting], it is
required to enter a name for this system.
Selecting the network setting method
Set a (static) IP address to this unit. Select the method for acquiring
a (static) IP address between [DHCP] and [Static IP Address].
[UPnP]:
•
•
If you do not use UPnP, set [UPnP] to OFF.
[Global IP address]:
[DHCP]:
•
When [UPnP] is set to OFF, enter the static global IP
address of the router for use in your site.
Check this when you will acquire an IP address with DHCP
.
*
A DHCP server (or a router) is required to acquire an
IP address with DHCP. A router may not have the setup
[Multicast address 1 – 5]:
Required
•
function depending on some models. For information about
setting a router, see the instruction manual for the router.
Enter the multicast addresses for the following:
1: For sound communication for paging between sites
2: For sound communication for paging in your site
3: (Not available)
4: For video communication in your site
5: For video communication between sites
[Static IP Address]:
•
Check this when you set the static IP address manually,
and then enter the static IP address suitable for the
network you are using, subnet mask, etc.
*
It is required to enter the static IP address and
subnet mask.
*
Do not use multicast addresses that overlap those of
other devices connected to the same network.
[Unit name]:
•
•
[Audio/video port]:
Required
•
Enter a name for this unit.
Enter the port numbers used for audio and video
communication.
* This name is used for searching for this unit in the
network. If not named, this unit is recognized only by
the unit (station) type and MAC address.
*
Do not use port numbers that overlap those of other
devices connected to the same network.
[Connection port], [Connection Password]:
Required
Enter the port number for controlling communication and
the password for security. Use the same port number
and password among the IP host unit and IP client units
within the site.
Temporarily stored
Click
to save the current setting
3
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
NOTES:
•
The IP host unit must not have an IP address identical to the IP
address of a remote site’s IP host unit.
•
The items that cannot be entered or selected are grayed out.
Temporarily stored
Click
to save the current setting
3
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the administrator ID and password
[Administrator setting]
Confirming the IP units connected to the
system [IP unit search]
We recommend that you change the administrator ID and
password from default to unique ones for security purposes.
Before configuring system wide settings, confirm the IP
units are connected to the network, and set the network
setting for each IP unit using [IP unit search].
*
*
This setting can be made to each of the IP units in your site.
“aiphone” is preset as the default for both ID and password.
Click IP unit search in the table of contents.
1
Click Administrator setting in the table of contents.
1
2
IP unit search
Click
.
2
All the IP units connected to the system are displayed in
the list.
Make the settings on the following items displayed in
the setting window.
*
If IP units are not displayed, repeat this step until
displayed.
[New administrator ID]:
•
•
•
•
Enter the new ID.
Confirm the “Station type”, “MAC address” and “Unit
name” of the IP units in the list.
3
4
[Current Password]:
Enter the current password.
[New Password]:
To make or change settings to an IP unit,
check the box for the target IP unit and click
Enter a new password.
Open the setting window
.
[New Password (Re-type)]:
Another window opens. You can make settings for the
Enter the new password again.
target IP unit individually. (→P. 16)
Temporarily stored
Click
to save the current setting
3
results temporarily.
Close the window.
5
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
*
Repeat step 3 to 5 to make settings to other IP units.
NOTE:
NOTES:
The system administrator must keep the ID and password without
fail. If you forget the ID and password, you must initialize the unit,
thus all the setting contents return to default.
•
•
This procedure cannot search for PC master stations (IS-SOFT)
and it is not a system failure. To add a PC master station (IS-SOFT)
in the system, install the application (IS-SOFT) to a PC before
connecting it to the network and see page 19.
It may be required to log in to open the setting window, and update
the system at [Updating the system] before closing the window.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Registering areas and remote sites
[System setting – Area/Site registration]
Required
Registering zones
[System setting – Zone registration]
Register zones for paging (transmitting announcements) in
your site. The number to which a name is entered is registered
as a zone number. Up to 99 zones can be registered.
Register areas (for separating stations in your site) and/
or remote sites. The number to which a name is entered is
registered as an area or site number. Up to 99 areas and/or
sites (up to 31 for sites only) can be registered.
* Zones are groups of stations designated for paging.
Click Zone registration in the table of contents.
1
Click Area/Site registration in the table of contents.
1
Enter a zone name in the cell for the target zone
number.
2
Enter an area name in the cell for the area number 01.
2
*
The figures under "Number" in the table means the zone
*
Be sure to enter an area name. A site cannot be
registered to the number 01.
number.
*
The figures under “Number” in the tables means the area
or site numbers.
Enter zone names in the cells for other numbers to
register more zones.
3
4
Enter area and/or site names in the cells for other
numbers to register more areas and/or sites.
3
Temporarily stored
Click
to save the current setting
results temporarily.
Select “Area” or “Site” from the pull-down menu of “Area/
Site”.
•
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
For a site, enter the IP address (global IP address of the
target site), port number and connection password for
the target site.
•
For a site, set “Door release” to enable (ON) or disable
(OFF) the door release action from the target site.
•
Temporarily stored
Click
to save the current setting
4
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
NOTES:
•
Be sure to register at least one area to the area number 01.
(“1” is entered in the cell for the area number 01 as default.)
•
A call number displayed on the master station monitor consists of
an area number plus a station number (when called from within
your site).
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Registering IP units [System setting – IP
unit registration]
Register IP units by selecting from the connected ones to the
system.
*
To register a PC master station, first install the application
(IS-SOFT) to a PC, then connect the PC to the network and
then start IS-SOFT.
Click IP unit registration in the table of contents.
1
IP unit search
Click
.
2
All the IP units connected to the system are displayed in
the [Search result] on the lower side of the window.
*
If IP units are not displayed, repeat this step until
displayed.
Check the boxes for the IP units you want to register,
3
4
Add to the imported IP units list
and then click
.
The checked IP units are registered and displayed in
[Imported IP units list] on the upper side of the window.
Enter data or change settings for the registered IP
units as needed.
*
For "Port number", the sequential numbers are
automatically assigned as needed. (You can also enter
port numbers manually.)
*
Do not use port numbers that overlap those of other
devices connected to the same network.
Port number auto-setting
:
•
•
Click this to assign sequential port numbers
automatically.
Port forwarding setting
:
Click this and you can confirm the port forwarding
settings to be made on the router in another window.
*
*
If [UPnP] is set to OFF at [Network setting:
Common], make the port forwarding setting on the
router with the set contents in this window manually.
Reload
Click
on this window to update the current
Close
port forward setting, and click
window.
to close this
Temporarily stored
Click
to save the current setting
5
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
NOTE:
A PC master station must be also registered as an IP unit. First
install the application (IS-SOFT) to a PC, then connect the PC to the
network and then register it.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
How to select multiple stations
Registering stations
[System setting – Registering stations]
○ Click to check the stations you will register.
Register all the stations connected in the system, and set the
area, station no. and station name to them.
Click Registering stations in the table of contents.
1
○ By clicking the button on the top of the list, you can
check or cancel all the stations on the list.
Set the area, station no. and station name to the
target stations.
2
*
*
*
Setting the station no. is required to register the
station to the system.
For a cell with the
pull-down menu.
mark, select the target one from the
Temporarily stored
Click
to save the current setting
Do not set stations with the same number in an area.
3
results temporarily.
NOTE:
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
The name of a master station displayed on its monitor in standby
mode is up to 16 alphanumeric characters.
Other buttons
Connection check
•
Click to confirm the connected units.
Connected: yellowish green
Not connected: gray
Station type error: pink
[Collective setting]:
•
The following buttons are used to make the settings to all
the checked stations at one time.
*
Pressing each button opens another window.
NOTE:
Be sure to check all the target stations before using these
buttons.
Area
•
•
Click to set the same area number to all the checked
stations.
Station number
Click to assign sequential numbers to all the checked
stations from top to bottom. The number you enter will
be set as the first number and will be assigned to the top
station of the ones checked. Other checked stations will
be numbered sequentially.
Station name
•
•
Click to assign the same station name and sequential
numbers to all the checked stations from the top down.
Enter a name only.
Station type
(Not available in a network direct system.)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Making detailed settings to stations
[System setting – Advanced station settings]
Making detailed settings to door
stations
Make detailed settings for the registered stations. The settings
can be made to a station individually, or multiple stations of the
same type at a time. The setting items differ from the station
type. First select a station (or stations), and then open the
“Advanced settings” window to make the settings.
The following setting item buttons are displayed in the
“Advanced settings” window.
A
B
Basic setting procedure
Click Advanced station settings in the table of
contents.
*
*
Click either the button A or B to open the
corresponding setting window, and then make the
settings in the displayed window(s). See the detailed
instructions for A or B below.
Close
the previous window.
Click
to close the current window and return to
Click to check the station(s) where detailed settings are
to be made.
*
*
Multiple stations of the same type can be set together.
All stations of the same type can be selected by clicking the
corresponding button under [Select all by type].
A
Settings on [Called stations] setting window
Set the master station(s) in your site and/or a remote site
that is (are) to be called from the selected station(s).
*
Advanced settings
The “Advanced settings” window for the selected station type
opens.
Up to 20 master stations in your site can be set. Or up to
19 master stations in your site and a remote site (up to 20
master stations are to be set at the remote site) can be set.
Click
.
Select the “Call priority” from the pull-down menu.
1
2
Reference
Click
to open another window, then check
Close
Make the settings in the displayed windows.
the target master stations, and then click
return to the previous window.
to
The selected master stations are added and displayed in
the list.
For door stations
The right column of this page
* Click
to open another window for
Remote sites
selecting the remote site as the target to be called from
the selected station(s).
For master stations
P.22
When you have finished making all the detailed settings:
Temporarily stored
Click
results temporarily.
to save the current setting
*
To delete a station (or stations) and/or remote site from
the list, check the targets in the list and click Delete .
*
If you wish to cancel the setting results you have made, click
a title in the table of contents or “Refresh” in the web browser
menu.
Repeat step 2 to add more master stations.
3
4
Close
Click
to close the current window and return to
the previous window.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
B
Settings on [Other] window
Making detailed settings to master
stations
[Transmit volume boost at PTT]:
•
Select whether to increase the press-to-talk sound
volume transmitted to the stations (ON) or not (OFF).
The following setting item buttons are displayed in the
“Advanced settings” window.
[Camera zoom image preset]:
•
Select the default of camera’s Zoom/Wide function at
calling from the 9 zoom positions and "0" (wide) from the
pull-down menu.
C
D
[Call acknowledge tone on/off]:
•
•
Select whether to sound the call acknowledge tone of
door station (ON) or not (OFF).
*
*
Click either the button C or D to open the
corresponding setting window, and then make the
settings in the displayed window(s). See the detailed
[Backlight adjustment]:
Select the method of adjusting the backlight in the
daytime between “Exposure +” and “Exposure –”.
instructions for
Close
or
below.
C
D
Close
•
Click
to close the current window and return to
the previous window.
Click this to close the current window and return to the
previous window.
About the priority
The order of priority for actions (communication, calling, paging,
monitoring, etc.) is as follows depending on the priority setting.
C
Settings on [Stations to be scan monitored]
window
Set the scan-monitoring target sub station(s).
Priority
1 (high)
2
Setting
Action
*
Up to 20 sub stations in your site can be set.
[Urgent], [Broadcast] Communication, calling,
paging
[Priority]
[Normal]
-
3
Reference
Click
to open another window, then select
1
4 (low)
Monitoring, scan-monitoring
Close
the target stations, and then click
the previous window.
to return to
The selected stations are added and displayed in the
list.
*
To delete a station (or stations) from the list, check the
Delete
target station(s) in the list and click
.
Repeat step 1 to register more stations.
2
3
Close
Click
to close the current window and return to
the previous window.
D
Settings on [Other] window
[Master station function: paging, chime, monitor,
door release, and remote site call]:
•
Select whether to enable the following functions of
master station (ON) or not (OFF).
Starting paging
•
•
•
•
•
Starting chime paging (Not available)
Monitoring/scan-monitoring
Releasing door
Remote site call
Close
•
Click this to close the current window and return to the
previous window.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Registering stations to zones
System setting – Zone setting]
Registering daily transfer schedule
[Transfer setting – Registering daily
transfer schedule]
[
Assign stations to the registered zones.
You can set the schedule for transferring calls to other
master stations in your site or remote sites automatically. The
schedules registered on this setting are used when making a
transfer setting on a master station.
Click Zone setting in the table of contents.
1
Up to 2 daily schedules can be registered.
Click Registering daily transfer schedule in the
table of contents.
1
Select a zone from the pull-down menu.
2
[Schedule number]:
Select the schedule number DT1 or DT2 from the
pull-down menu.
2
Reference
Click
to display all the registered stations
3
4
in your site.
Another window opens and the registered stations are
displayed in the list.
[Schedule name]:
Enter the name of daily schedule.
3
Check to select the target stations.
[Call transfer time]:
Set the [Start time (hour and minute)] and [End time
(hour and minute)] of transferring.
4
Temporarily stored
Click
to save the current setting
5
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
Select stations in the following ways.
Select stations by checking one by one.
•
•
All stations of the same type can be selected by
clicking the corresponding button under [Select all by
type].
By clicking the button on the top of the list, all the
stations are checked or canceled.
•
Close
Click
after you have finished selecting the
5
6
stations.
In the previous window, the selection results are displayed
in the list.
*
When canceling a registered station, check the station in
the list, then click Delete .
Temporarily stored
Click
to save the current setting
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
E
Settings on [Weekly schedule] setting window
Setting transfer schedule
[Transfer setting – Transfer schedule setting]
1) Select either [Every week] or [Every other week].
2) Set the schedule start and end dates.
You can set a weekly transfer schedule and individual daily
schedule.
*
The monthly calendar is displayed by clicking
Refer calendar and you can select the start and
end dates.
*
The settings can be made 1 year ahead.
Click Transfer schedule setting in the table of
contents.
*
If necessary, you can change the month by clicking
1
or
.
3) Set one of the registered daily transfer schedules or no
schedule to each day of the week. (Select one from the
pull-down menu.)
Weekly schedule
Make the settings by clicking
Individual schedule
and
corresponding window.
2
respectively to open the
F
E
F
Settings on [Individual schedule] setting window
Set an individual schedule to the target date.
*
[Individual schedule] setting window will not open if you
have not selected the target date on the calendar in the
[Transfer schedule setting] window.
Individual schedule
*
should be clicked after the target
date is clicked on the calendar.
or
1) If necessary, you can change the date by clicking
Make the settings in the displayed window(s).
repeatedly.
3
4
2) [Daily transfer schedule]:
Select either of the registered daily schedules (DT1 or
DT2) or no schedule from the pull-down menu.
E
F
See the detailed instructions for
right column of this page.
or
on the
3) [Call transfer time]:
When “DT1” or “DT2” is selected:
•
The call transfer time is automatically entered.
If necessary, change the [Start time (hour and
minute)] and [End time (hour and minute)] of
transferring manually.
After the setting is finished on the corresponding
Close
window, click
to close the window.
Calendar and setting status can be checked for the
selected month.
When no schedule is selected:
Enter the call transfer time manually.
•
The registered daily transfer schedules are
identified by colors and shown on the calendar.
*
When the time is entered or changed manually, [Daily
transfer schedule] changes to “Individual schedule”.
Temporarily stored
Click
to save the current setting
5
6
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
When the settings on this window have finished, update
the system from [Updating the system]. (→P. 28)
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the timer [Timer setting]
Set the time for each operation.
Click Timer setting in the table of contents.
1
Set the time for the following operations respectively.
2
*
The setting range is displayed on the right side of each
input box.
[Call]:
•
Set the duration of call from door stations to [Normal],
[Priority] or [Urgent].
[Communication]:
•
Set the duration of communication between stations in
the system including between remote sites [Via IP].
*
[In Local] and [Telephone]: Not available in a network
direct system.
[Paging]:
•
•
•
Set the duration of paging.
[Monitor]:
Set the duration of monitoring only one station.
[Scan monitor: Switching]:
Set the duration of monitoring each station while scan-
monitoring.
NOTE:
The actual duration slightly differs from the setting value.
[Contact output]:
•
•
(Not available)
[Door release]:
Set the duration of door release.
*
If you set the time to “0”, the door is released while
the door release button on the master station is held
down.
Temporarily stored
Click
to save the current setting
3
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
G
Settings on [Remote site master call] setting
window
You can set a station (master station or door station) that
receives a call from a master station in a remote site. One
station can be set for each priority.
Setting stations to receive calls and
zones to receive paging from remote sites
[Remote site pilot call setting]
Set the master stations and sub stations to receive calls, and
zones to receive paging from remote sites.
Reference
Click
for “Normal”.
1)
All the registered stations are displayed in the list in
another window.
*
The setting can be made for each priority individually.
2) Check the box for the target station in the list, and then
Click Remote site pilot call setting in the table of
contents.
Close
1
click
.
The current window closes and the set station is
displayed in the [Remote site master call] setting
window.
To delete a set station
Delete
Click
*
for "Normal".
Advanced settings
for
respectively to open the
Make the setting by clicking
Selecting another station also overwrites the previous
one.
2
G
H
I
the setting items
,
,
corresponding window.
Make the setting for “Priority” and “Urgent” in the same way.
Settings on [Remote site door call] setting
window
H
G
H
*1
I
You can set up to 20 master stations that receive a call
from a door station in a remote site. Up to 20 master
stations can be set for each priority.
Reference
Click
for “Normal”.
1)
All the registered master stations are displayed in the
list in another window.
*2
2) Check the boxes for the target master stations in the
Close
list, and then click
.
The current window closes and the set stations are
displayed in the [Remote site door call] setting window.
Make the setting in the displayed window(s).
3
To delete a set station
Delete
Check the box for the target station and click
.
G
H
I
See the detailed instructions for
right column of this page.
on the
,
,
*
You can also select two or more stations and delete
them at a time.
Make the setting for “Priority” and “Urgent” in the same
way.
After the setting is finished on the corresponding
4
5
Close
window, click
to close the window.
I
Settings on [Remote site paging] setting window
You can set a zone that receives paging from a remote
site. One zone can be set for each priority.
Temporarily stored
Click
results temporarily.
to save the current setting
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
1) Select the target zone from the pull-down menu for
“Normal”.
*
Make the setting for “Priority”,“Urgent”and “Broadcast”
in the same way.
*1: The settings on this item are available for a call from the
standard (IP) system in a remote site. The setting method is
H
the same as the item . (Refer to the “SETTING MANUAL”
for a standard (IP) system for details.)
*2: Not available
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Video setting
Setting time and date
[Time and date setting]
Click Video setting in the table of contents.
Set the following settings for video quality.
1
2
Set the time and date of the system, used for transfer schedule.
Click Time and date setting in the table of contents.
1
[Frame Rate]:
•
•
Set the frame rate selecting “1”, “2”, “5”, “7.5”, “10” or “15”
fps from the pull-down menu.
[Quality]:
Set the following settings.
Set the video quality selecting “Low”, “Middle”, “High” or
“Excellent” from the pull-down menu.
2
Required
[Set current time]
:
•
Temporarily stored
Click
to save the current setting
Set the current time and date in one of the following
methods.
3
results temporarily.
Input the current time and date manually, and then
•
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
Manual setting
click
.
Synchronized with PC
Click
to set the current time
•
•
and date by making it synchronized with the PC.
NOTE:
You can also set the current time and date by making it
synchronized with NTP server [Synchronized with NTP
server] as shown below.
Raising [Frame Rate] from 1 to 15 fps gives you a smoother image
quality. Also, raising [Quality] gives you a finer image. However, if
both [Frame Rate] and [Quality] are raised at the same time, a large
amount of network bandwidth will be required.
*
If there is no power supply to the system for a long
time because of power failure etc., the time and date
setting may be cleared.
[NTP (Network Time Protocol)]:
•
Set [Synchronized with NTP server] to ON to set the
current time and date by making it synchronized with
NTP server. Then set the [NTP server] and [NTP port
number].
*
[NTP server]:
Enter the IP address or domain name of the NTP
server to be used as the master clock.
[UTC time zone]:
•
Set the time differences from Coordinated Universal
Time (UTC). Set the [Hour difference] and [Minute
difference] respectively.
[Synchronize interval]:
•
•
When [Synchronized with NTP server] is set to ON, the
current time and date are set by being synchronized
with the NTP server with the entered time interval.
[Daylight savings time]:
Set whether to utilize daylight savings time (ON) or
(OFF). When set to ON, then set the start and end
times (Month, Week of the month, Day of the week,
Hour and Minute), and time differences (Hour and
Minute).
*
It is recommended to connect the system with a PC or
NTP server constantly to keep the correct time and date
setting.
Temporarily stored
Click
to save the current setting
3
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
E-mail setting
Downloading/uploading setting data
[Setting file]
You can send an e-mail when calling or send error messages
etc. by e-mail. Up to 3 mail addresses can be set.
You can download the setting data you have made into a file
and save it on the PC. On the contrary, you can upload the
setting data from the PC.
NOTES:
•
•
Prepare an e-mail account for this function beforehand.
Make sure to enter the system name at [Network setting:
Individual] – [System name] to display the title with an e-mail.
Make sure to enter primary and/or secondary DNS server
information at [Network setting: Individual] to all the IP units.
*
It is recommended to download the setting data as a backup
copy after you finish making settings or setting changes.
•
When downloading setting data onto the PC
Click Downloading setting data in the table of
contents.
■
Click E-mail setting in the table of contents.
1
1
2
Set the following settings.
[Email destination address]:
•
•
•
Enter up to 3 mail addresses (destination addresses).
[Email source address]:
Click
to download the current setting data
Download
2
Enter the source mail address.
into a file.
[SMTP authentication]:
Configure SMTP authentication as required by source
E-mail provider.
When uploading setting data
■
Click Uploading setting data in the table of contents.
1
[Language selection]:
•
Set the language you want to use for entering the system
name.
*
You can use English only for the body of the message.
[Mailing event]:
•
Click
to the system.
You can select the setting data file from another window,
and upload it.
to upload the setting data from the PC
Upload
2
3
Select mailing events by setting the target ones to [ON].
Temporarily stored
Click
to save the current setting
3
results temporarily.
*
If you wish to cancel the setting results you have made,
click a title in the table of contents or “Refresh” in the
web browser menu.
Update the system.
*
Refer to “Updating the system” below.
NOTE:
Uploading the setting data will overwrite the current data.
Updating the system
[Updating the system]
Update the system with the setting data you have entered
(currently stored temporarily).
Click Updating the system in the table of contents.
1
Click
to update the system with the setting
Update
2
data currently stored temporarily.
NOTE:
Do not turn off the system while updating the system.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
MAINTENANCE
This section describes the use of functions for the system maintenance. These functions are available on the web server.
Initializing the system [Initialization]
Updating the firmware [Firmware update]
Downloading updated firmware data
You can reset the system settings to factory default.
■
download the firmware data on the PC to update the system.
For the download procedure, see the instructions on our web
page.
Access the web browser and log in.
(→P. 14)
1
Click Initialization in the table of contents.
2
Access the web browser and log in. (→P. 14)
1
Click Firmware update in the table of contents.
2
Click
.
Initialization
3
Downloading system log [System log]
Click
.
Update
3
Another window opens.
You can acquire the system operation log.
Click
and select the target firmware.
Browse...
Access the web browser and log in.
(→P. 14)
4
5
1
When the firmware is displayed in the window, click
Upload
Click System log in the table of contents.
.
2
When “Update firmware.” is displayed, the update process
is complete.
NOTES:
•
If the power is turned off while it is writing, the product will
malfunction.
Click
to acquire the log from the system.
Download
3
4
•
The system may not operate normally while updating the
firmware.
Confirm the log, and save it as needed.
NOTE:
NOTE:
If the update fails, try again.
The log is overwritten constantly from the oldest records.
Referring to the troubleshooting guide
[Troubleshooting]
Click Troubleshooting in the table of contents.
1
The following information appears in the window.
Information about the online-help that you can refer to
when trouble occurs in setting the system
Supported characters and symbols
•
•
Registering your system [Registration]
Click Registration in the table of contents.
1
2
Register
Click
to open the registration window, and
then register your system on the window.
*
If you use an IS-SOFT in the system, enter the license
key of the IS-SOFT.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Information Memo
Record your settings information. It will need when resetting or maintenance.
Host unit
Network setting: Individual
Static IP Address
Default Gateway
Primary DNS Server
MAC address
Subnet Mask
Secondary DNS Server
Unit name
Connection port
Network setting: Common
Global IP address
Connection port: global
Multicast address 1:
3:
Connection Password
2:
4:
5:
Audio/video port
Administrator setting
ID
Password
IP Address
Client unit
Network setting: Individual / Administrator setting
#
1
Unit name
MAC address
ID
Password
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
* Download and save the setting data on the PC. Refer to [Setting file] for details.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE S.A.S., LISSES-EVRY, FRANCE
Download from Www.Somanuals.com. All Manuals Search And Download.
|