Acu Rite Automobile Accessories 516353 21 User Manual

SENC 50  
REFERENCE MANUAL  
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Table of Contents  
Page  
Page  
Checking the Installation.................................................... 10  
Electrical Shielding.............................................................. 11  
Troubleshooting ................................................................... 12  
Introduction / Supplied items ............................................... 2  
Key Points / Tolerances ......................................................... 3  
Linear Encoder Dimensions .................................................. 4  
Spar Dimensions .................................................................... 5  
Mechanical Specifications ................................................... 13  
Output Signals and Pin-Outs.............................................. 14  
Electrical Specifications ...................................................... 15  
Mounting Requirements........................................................ 6  
Typical Mounting ................................................................... 7  
Encoder Installation Procedure ............................................ 8  
The Acu-Rite Companies Inc.  
Hassle Free Warranty & Service ........................................ 16  
Adjustable front or  
rear mount  
Spar  
Front mount  
bracket  
Front mount  
bracket  
Bottom mount  
bracket  
Base mount  
• Installation brackets and kits are available.  
• Your Authorized Distributor can assist you in selecting  
brackets and tools for your installation.  
1
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction / Supplied Items  
SENC 50  
The SENC 50 Precision Glass Scale Linear Encoder provides For future ordering information or warranty service, record the  
the accuracy and reliability of an Acu-Rite Companies Inc. linear encoder catalog and serial numbers.  
measuring system in a very small cross-section with digital  
Catalog #  
Serial #  
Manufacture Code #  
output (analog output available). Features and options include:  
Axis # 1:  
Axis # 2:  
Axis # 3:  
Axis # 4:  
_____________________________________  
_____________________________________  
_____________________________________  
_____________________________________  
Resolutions of 0.5, 1.0 or 5µm.  
Accuracy grades of ± 3 or ± 5 µm / 1000mm.  
Position Trac or 50mm interval Reference Mark.  
Vinyl or Armor cables of 5, 13, & 19 ft. lengths.  
Mounting fasteners, center supports, and backup spar.  
Installation tools, brackets, and accessories.  
Date of Purchase _____________________________________  
Distributor:  
_____________________________________  
The SENC 50 is especially useful for applications with limited  
space such as X/Y stages and compact metrology equipment.  
Contact your Authorized Distributor for assistance with selection  
of product options and accessories.  
Address:  
Telephone:  
_____________________________________  
_____________________________________  
Shipping carton  
contents  
B
A
A) SENC 50 linear encoder  
B) Reference Manual  
C) Encoder and Cable  
Mounting Hardware  
C
Acu-Rite Companies Inc.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Key Points / Tolerances  
// .005 B  
// .005 A  
Use this information to plan your Linear Encoder installation.  
• Understand your mounting requirements.  
• Follow kit instructions when using an Acu-Rite Companies  
Inc. bracket kit.  
• Mount encoders close to ways to insure system accuracy.  
• Mount with lip seals down and away from the work area.  
• Brackets should be short and rigid.  
// .005 A  
Gap  
.059 ±.005”  
[1.50]  
B
-A- = Machine travel  
Center support surface  
required  
Reading head  
assembly  
Scale assembly  
• Surfaces must be in good condition, clean and free of  
dirt and paint.  
// .005 A  
Do not remove shipping brackets until instructed.  
// .005 A  
• Shipping bracket spacers can be used to insure .059” gap.  
• Mount from either side to obtain desired cable exit direction.  
Equal  
Equal  
• Tolerances of .005” TIR apply to all mounting dimensions.  
Center support surface required for all measuring  
lengths when not using a back up spar.  
Shipping bracket removal clearance  
Total head travel  
1.00  
1.00  
.037 [.9]  
Min.  
.26 [6.6]  
Min.  
Slide brackets away  
from the reading head  
Measuring length + 1”  
[25.4] over travel  
• Allow clearance for shipping bracket removal.  
• Limit equipment travel to less than measuring length.  
3
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Linear Encoder Dimensions  
SENC 50  
Measuring length + 4.65 [118]  
Measuring length + 4.09 [103.9]  
.280  
[7.11]  
Typ.  
.335  
[8.51]  
.482  
.670  
[17.00]  
[12.25]  
Scale case  
Mounting hole  
Scale assembly  
.Gap  
.059 ± .005  
[1.50]  
End cap  
1.182  
[30.00]  
Reading  
head  
Ø .16  
[4.1]  
Vinyl  
Ø .30  
[7.6]  
for M4  
Align both  
surfaces  
Strain relief  
Hex nut  
assembly  
.463  
and cable  
.140  
[3.55]  
Armor  
1.85  
[47.00]  
.170  
[4.32]  
[11.76]  
.02  
[0.5]  
2.0 [50] Approx.  
min bend radius  
of armor  
Ø .160  
[4.00] min.  
2.775  
[70.50]  
.175 [4.57]  
Typ.  
.280  
[7.11]  
.840  
[21.34]  
2.350  
[59.69]  
.213  
[5.41]  
Typ.  
1.352 [34.34]  
.150  
[3.81]  
Spar  
.170  
[4.32]  
.652  
[16.56]  
.138  
[3.50]  
.295  
[7.50]  
.159  
[4.04] Typ.  
M3 x .25 [6.31]  
deep min.  
Acu-Rite Companies Inc.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Spar Dimensions  
Backup spar  
Part Number  
680803-01  
680803-02  
680803-03  
680803-04  
680803-05  
680803-06  
680803-07  
680803-08  
680803-09  
Linear Encoder  
Measuring Length  
L
A
X No.  
Places  
B
Backup spar  
Part Number  
Linear Encoder  
Measuring Length  
L
A
X No.  
Places  
B
1
2
3
4
5
6
7
8
9
5.650  
6.650  
7.650  
8.650  
9.650  
10.650  
11.650  
12.650  
13.650  
.825  
.825  
2
2
2
2
2
2
2
2
3
4.000  
5.000  
5.000  
5.000  
5.000  
5.000  
5.000  
5.000  
5.000  
680803-10  
680803-11  
680803-12  
680803-13  
680803-14  
680803-15  
680803-16  
680803-18  
680803-20  
10  
11  
12  
13  
14  
15  
16  
18  
20  
14.650  
15.650  
16.650  
17.650  
18.650  
19.650  
20.650  
22.650  
24.650  
2.325  
2.825  
3.325  
3.825  
1.825  
2.325  
2.825  
1.325  
2.325  
3
3
3
3
4
4
4
3
3
5.000  
5.000  
5.000  
5.000  
5.000  
5.000  
5.000  
10.000  
10.000  
1.325  
1.825  
2.325  
2.825  
3.325  
3.825  
1.825  
Spar  
fastener  
Encoder  
retaining clip  
Spar leveling  
screws  
Backup spar mounting optional for all lengths  
Ø .196 Drill thru  
Ø .344 C’bore x .100 Dp.  
“X” no. of places  
Clip mounting  
screws  
.075  
.330  
Backup spar  
mounting  
.510  
“A”  
Ref.  
“A”  
± .005  
B Typ. ±.005  
Non accumulative  
±.015  
L
5
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Requirements  
SENC 50  
Mounting options can be adapted to machine mounting surfaces  
using spacers, standoffs, and leveling screws.  
Center support  
assembly  
• Measuring length and mechanical configuration of your  
equipment determines your options.  
• Length related mounting options shown.  
• When a backup spar is used, mount the backup spar following  
the same procedure as required for mounting without a backup  
spar, using the same tolerances.  
• 8” and larger: End mounting holes with center support.  
End mounting holes  
• 7” and smaller: End mounting holes with encoder mounted to  
a continuous flat surface, or with center surface on same plane  
as end mounting surfaces.  
Acu-Rite Companies Inc.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Typical mounting  
Spar mounting  
A variety of mounting conditions can be accommodated.  
• Mechanical configuration of the equipment determines  
brackets and adapters required to install the linear encoder.  
• Three typical conditions are shown for reference.  
// .030  
• Flush or offset mounting surfaces using a spar.  
• Reading head mounting bracket required (bottom mounting  
bracket example shown).  
Flush mounting surfaces  
Offset mounting surfaces  
// .030  
// .005  
• Mounting surfaces are flush within .005”.  
• Installation without a backup spar.  
• Offset mounting surfaces using a reading head bracket.  
7
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Encoder Installation Procedure  
SENC 50  
These steps apply to all mounting conditions. Although this  
may not pictorially represent your application, your installation  
procedure should follow these steps.  
Center mounting axis  
Acu-Rite Companies Inc. Bracket Kit instructions  
supercede this section.  
• General steps for small X & Y stage.  
• Adjust drill depths and fastener lengths as required.  
• Contact your Authorized Distributor if assistance is required.  
C
L
Mark center of axis  
• Center the axis.  
• Mark the axis for easy return to center.  
Underside of end caps to be  
flush with parting line of  
upper slide.  
Keep head and  
Align top of scale case to  
within .015” of axis travel  
scale case  
Scale case  
surfaces flush  
C
L
Scale case  
Strain relief  
Shipping  
brackets (2)  
Mark end mounting  
hole location  
End cap  
and  
Reading head  
cable assembly  
• Center the reading head on the scale case by sliding the head • Locate the linear encoder along the axis parting line.  
and shipping brackets together along the scale case.  
• Mark location of one end mounting hole in the scale case.  
Acu-Rite Companies Inc.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Installation Procedure  
Align to within  
.005”  
to axis travel  
Use shipping brackets  
to maintain .059  
gap between  
Drill / tap for 6-32  
(M3).  
Axis  
travel  
head and  
scale case.  
Drill / tap  
for 6-32 (M3).  
C
L
6-32 x 3/4” SHCS & M3  
flat washer (M3 x 20mm)  
6-32 x 3/4” SHCS & M3  
flat washer (M3 x 20mm)  
• Drill / tap the first end mounting hole / Attach the scale case. • Center the axis and mark the reading head mounting holes.  
• Align to within .005” TIR. and drill / tap second end hole. • Move the axis and drill / tap holes for 6-32 (M3).  
• Attach scale case & align to within .005” TIR. of the axis travel. • Attach head and align to scale case to within .005” TIR.  
Slide bracket from reading head  
and twist 45°  
6-32 x 3/4” SHCS & M3 flat washer  
(M3 x 20mm)  
Retaining clip  
Shipping bracket  
Center support  
(2)  
• Slide shipping brackets from reading head and twist to remove  
from the scale case.  
• Save the shipping brackets with the Reference Manual.  
• Use center supports when provided.  
• Place at uniform intervals along the scale case.  
9
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Checking the Installation  
SENC 50  
Connecting  
These steps will confirm proper operation of your installation.  
Counting tests check channel A and B output function and  
Reference Mark tests check Reference Mark operation.  
Provide slack  
loops  
• Configure the readout for proper counting resolution.  
• Move axis and compare the display to the movement.  
• Repeat test for mechanical integrity and repeatability.  
• Configure the readout for sensing reference mark.  
• Move the reading head approximately 20mm.  
• Locate an indicator on scale end and zero out axis and  
indicator.  
Secure excess  
cable  
• Move axis out and back over full travel and return to dial  
zero.  
• Electronics should read zero ± 1 count.  
• Route the cables with slack loops to allow for axis motion.  
• Secure excess cable by fastening with clips or ties.  
• Attach the linear encoder connectors to the readout.  
Place indicator at end of  
Counting Test  
moving component (scale case  
shown, or reading head).  
Readout  
Repeatability Test  
Readout  
• Zero the display and indicator.  
• Move axis to the end of it’s travel, then return to dial zero.  
• Readout should read zero ± 1 count.  
• Check function of the linear encoder.  
Acu-Rite Companies Inc.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Electrical Shielding  
Connect a ground wire from the terminal on the back of the  
readout to the machine or earth ground. Attach a ground wire  
from the machine to a solid earth ground.  
With the encoder attached to the machine and the cable  
connected to the readout, check shielding by measuring  
resistance between connector housing and scale unit. Desired  
value: 1 Ω max.  
11  
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble Shooting  
SENC 50  
If you experience difficulties with your installation, there are  
methods to analyze the difficulty. Operating difficulties can be  
caused by either the linear encoders or the readout.  
with other machine structures through the length of the linear  
encoder travel.  
• Check for loose fasteners. If you find loose fasteners, first  
confirm that the linear encoder is installed to the tolerances  
specified and then retighten the fasteners as required.  
• Confirm that the linear encoder is installed to the required  
tolerances by checking the alignment tolerances specified on  
Page 3 “Key Points”. If the installation does not meet the  
tolerances, reinstall the linear encoder according to the  
procedures in “Installation”.  
Checking the readout  
Follow the steps below to determine if your difficulties are  
associated with the readout:  
• Insure that the linear encoder connectors are correctly seated.  
• Swap linear encoder cables at the readout to see if the problem  
is still shown in the same display.  
• Perform a Repeatability Test as described on Page 10,  
“Checking Your Installation”. If the linear encoder is  
installed to the required tolerances, the bracketry and linear  
encoder have been checked for interferences and loose  
fasteners, and the linear encoder fails the repeatability test,  
the linear encoder is likely at fault.  
• If the problem remains in the same display, the readout is in  
error.  
• If the problem follows the connection change, the linear  
encoder may be in error.  
• Follow this procedure for any intermittent problem  
experienced.  
Do not attempt to repair the linear encoder. The units are only  
serviceable by assembly replacement. Attempted repair can  
permanently damage the unit and void the warranty.  
If the readout is at fault, refer to “What to do” to arrange for  
the parts necessary to repair your system. If the linear encoders  
appear to be the cause, perform the next step.  
Checking the Linear Encoders  
What to do  
Linear encoder difficulties can be caused by improper  
installation, loose or misaligned bracketry, or a damaged / failed  
linear encoder.  
If an Acu-Rite Companies Inc. linear encoder or readout is found  
to be at fault, prior to removing the linear encoders or readout  
contact your Authorized Distributor or OEM/OEI for repair  
instructions.  
Follow the steps below to determine the cause of your system  
difficulties:  
• Confirm that your bracketry and installation does not interfere  
Acu-Rite Companies Inc.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Mechanical Specifications  
Mechanical Specifications  
Digital  
Analog  
Resolution  
Grating pitch  
Scale medium  
0.5µm  
1µm  
5µm  
20µm  
Light transmission reflective off of chrome coated glass  
Accuracy (@ 20° C) / 1000mm  
Max. slew speed (M/s)  
± 3µm, ± 5µm  
1
Force required to move  
reading head  
< 0.5 (lbs)  
Operating Environment  
Temperature  
Relative Humidity  
0° to 50° C  
20% to 95% (non-condensing)  
Storage Environment  
Temperature  
Humidity  
- 20° to 70° C  
20% to 95% (non-condensing)  
Weight  
1.1 + 0.2 lbs/ft of measuring length [64g + 5.6g/in.]  
Connecting cable  
armored or vinyl  
Length = 5, 13, and 19 ft.  
Connector: DE-9P  
Length = 5, 13, and 19 ft.  
Connector: DE-9P  
Max. cable length (ft)  
Measuring lengths  
20  
26  
75  
75  
1” - 20”  
Reference pulse interval  
Repeatability  
50mm fixed or Position Trac  
Within one resolution count  
180  
Operating current (ma)  
Protection (IEC 529)  
220  
IP 53 when installed as per instruction  
13  
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Output Signals and Pin-Outs  
SENC 50  
Digital Differential  
Pin 1  
N/C  
Pin 2  
Green  
Pin 3  
Pin 4  
Pink  
Pin 5  
Red  
Pin 6  
White  
Pin 7  
Black  
Pin 8  
Gray  
Pin 9  
Yellow  
Brown  
N/C  
Channel Channel Channel Channel  
Ground  
Vcc, + 5.1  
± 0.1 VDC  
Channel Channel  
A+  
A-  
B+  
B-  
R+  
R-  
1
5
6
9
Analog Differential  
Pin 1  
Pin 2  
Pin 3  
Pin 4  
Pin 5  
Red  
Pin 6  
N/C  
Pin 7  
Black  
Pin 8  
Blue  
Pin 9  
Violet  
White w/Grn Stripe & Brown Green  
Yellow Orange  
Ground  
Channel  
A+  
Channel Channel Channel  
A- B+ B-  
N/C  
Vcc, + 5.0  
± 0.1 VDC  
Channel Channel  
R+ R-  
Acu-Rite Companies Inc.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SENC 50  
Electrical Specifications  
Parameter  
Digital  
Analog  
Output Signals  
IOH=(High level output current) = 20mA  
VOH=(High level output voltage) >2.5Vdc  
0°  
90°  
360°  
0°  
360°  
IA, B:7-16 µApp  
or  
1
1
Channel B  
Channel A+  
Channel A-  
Channel R+  
Channel R-  
1 Count  
1.0 Vpp  
0
1
0
0
1
Channel A  
0
90°  
IR:2-8 µApp  
or  
1
Channel B+  
Channel B-  
Channel R  
(Phased)  
0
1
0
1.2 Vpp  
I
OL=(Low level output current) = -20mA  
VOL=(Low level output voltage) < 0.6Vdc  
Similar phasing, but differential  
sinusoidal current or 1 volt peak to peak output  
Incremental signals  
Signal levels  
Square-wave voltage signals.  
Channels A and B, in 90°  
quadrature relationship  
TTL-level  
7-16µApp or 1.0 Vpp  
w/1 K Ohm load  
Square-wave signal  
TTL-level  
Reference Mark signals  
Signal level  
Differential current or 1 volt peak to peak output  
2-8µApp or 1.2 Vpp  
w/100 K Ohm load  
5.0 ± 0.1VDC @ 75 mA max.  
5.1 ± 0.1 VDC @ 220 mA max.  
Power Supply  
15  
Acu-Rite Companies Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acu-Rite Companies Inc. Warranty  
SENC 50  
ACU-RITE Companies, Inc. is proud to offer the 3-Year Hassle-Free Warranty for all readout systems, and precision glass scales.  
This warranty will cover all of the ACU-RITE repair and replacement costs for any readout or precision glass scale returned  
during the three (3) year warranty period. ACU-RITE will repair or replace the damaged components regardless of the product’s  
condition absolutely free, no questions asked. This warranty covers both materials, and factory labor. In addition, authorized  
ACU-RITE service representatives will provide service labor (field service) for a period of one (1) year at no charge. Notice of the  
claimed defect must be received by ACU-RITE within the warranty period.  
This warranty applies only to products and accessories installed and operated in accordance with this reference manual. ACU-  
RITE shall have no obligation, with respect to any defect, or other condition caused in whole or part by the customer’s incorrect  
use, improper maintenance modification of the equipment, or by the repair, or maintenance of the product by any person except  
those deemed qualified by ACU-RITE.  
Responsibility for loss of operation, or diminished performance due to conditions beyond ACU-RITE’s control cannot be accepted  
by ACU-RITE.  
The foregoing warranty obligations are in lieu of all expressed or implied warranties. ACU-RITE Companies, Inc. shall not be  
liable under any circumstances for consequential damages.  
Acu-Rite Companies Inc.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Acu-Rite Companies Inc.  
IS AN  
ISO 9001  
CERTIFIED  
MANUFACTURER  
Acu-Rite Companies Inc.  
One PrecisionWay • Jamestown, NY 14701  
516353-21 Ve01 8/2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Acer Computer Monitor S243HL User Manual
ACP EP Memory Computer Drive EPSURF20 1GBBL User Manual
ADTRAN Power Supply ATLAS 890 User Manual
Advantech Computer Hardware UNO 2173A AF User Manual
Aiphone Weather Radio NE DA User Manual
Allied Telesis Network Card AT iBG915 User Manual
Alto Shaam Air Conditioner 1000 TH III User Manual
American DJ DJ Equipment Crusader User Manual
BB Electronics Power Supply M3LDY User Manual
Beko Refrigerator CDA 664 F User Manual