Supports the 9000 Series
PN 720-0104-00
April, 2004
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Note: 3DM 2 includes software developed by the OpenSSL Project
for use in the OpenSSL Toolkit (http://www.openssl.org/).
3ware Disk Manager 2 (3DM 2), allows you to view the status of and manage
3ware RAID controllers and associated drives. 3DM runs as a service under
Microsoft Windows, and as a daemon under Linux. When it is running, you
can use your browser to view status and perform administrative tasks locally
or remotely.
3DM 2 can display information about 3ware RAID 7000-, 8000- and 9000-
series RAID controllers. However, some version 2 features are only available
for 9000-series controllers.
Two levels of access are provided: user and administrator. Users have view-
only access—they can check the status of drives and units—while
Administrators can view and make changes, using 3DM to configure RAID
units and designate hot spares, and to perform maintenance tasks on RAID
units.
In this section, information about 3DM is organized into the following topics:
27
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
“3DM 2 Reference”contains information about the fields and settings on each
page in 3DM. For additional information about doing particular tasks in 3DM,
see the remaining sections in this guide.
Browser Requirements for 3DM
3DM runs in most current web browsers. Tested and supported browsers
include:
■ Mozilla 1.2 and above
■ Internet Explorer 5.5 and above
Additional requirements:
■ JavaScript must be enabled
■ Cookies must be enabled
■ For best viewing, use a screen resolution of 1024 X 768 or greater, and set
colors to 16 bit color or greater.
Note: Because 3DM may be viewed in different browsers, the
format and style of the 3DM browser windows illustrated in this
chapter are examples only. (Screenshots were taken in Internet
Explorer.) The actual “look” of the windows will depend on the
browser, 3DM version and operating system in use.
Setting up Mozilla
Details about accessing all ports, including port 888, by adding a list of ports
to /Mozilla/default/all.js
Note: For security reasons, some web browsers do not allow
connections to certain ports including port-1080 and 888. To
override this on a per-port basis, the Mozilla release notes
recommend to add a comma-separated list of ports to default/all.js
(in your Mozilla installation directory). For example, to unblock
port 888, use the following line:
pref(“network.security.ports.banned.override”, “888”)
This file is located at:
/usr/lib/mozilla/defaults/pref/all.js
28
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing 3DM
Installing 3DM
3DM 2 can be installed from the main 3ware CD that came with your 3ware
RAID controller. You can also download the current version from the website
3DM must be installed on the system in which the controller is installed. 3DM
does not have to be installed on remote systems in order to remotely manage a
3ware controller.
During installation, you will be asked to enter the following preferences for
3DM use. (Each of these preferences can be changed later, from within 3DM.)
■ The HTTP port to be used as the listening port
■ Whether remote access will be allowed
■ Whether you want email alerts to be sent when errors occur, and who
should receive them
Installing 3DM on a Windows system
The 3ware RAID controller works with Windows 2000, Windows XP, and
Windows Server 2003. The latest service packs should be installed for any
Windows release.
To install 3DM on a Windows system
1
Insert the 3DM CD-ROM and click Install 3DM 2 when the menu
appears.
Or, if you downloaded 3DM from the website, find the file
3DM2_x86.exe or 3DM2_AMD64.exe and double-click it to launch the
setup.
2
3
If a command window opens, press any key to begin the installation
process.
When the License Agreement screen appears, read and agree to the
license information; then let the InstallShield Wizard guide you through
the installation process.
4
On the 3DM Remote Monitoring and Security Configuration screen
(see Figure 10), use the settings to specify these things:
■ To change the HTTP port that 3DM will use as a listening port, check
the first box.
If you do not know which port to use, leave the box unchecked and
use the default port.
■ To allow remote administration, uncheck the second checkbox.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
When the second checkbox is checked, only localhost connections are
allowed. Internet and Intranet connections are not allowed.
(You can change this setting later in 3DM.)
Figure 10. 3DM Remote Monitoring and Security Configuration
Display
5
6
If the 3DM HTTP listening port setup screen appears, enter the HTTP
port you want to use.
This screen only appears when you check the first box on the 3DM
Remote Monitoring and Security Configuration screen.
(You can change this setting later within 3DM.)
On the E-mail Notification Preferences screen (see Figure 11) use the
fields to specify initial email settings.
Note: If you do not want email alerts to be sent to anyone,
leave “None”in these fields and click Next to go on to the next
screen.
■ In the Server field, enter the name of your email server.
If you do not know your server name, ask your system administrator
or check the e-mail preferences or setup options on your e-mail client.
■ In the Recipients field, enter the e-mail address of the user who
should receive the 3DM e-mail status messages.
You may enter multiple e-mail addresses, separating each entry with a
comma (,).
30
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing 3DM
■ In the Sender field, enter the email address from which the email
notifications will be sent. This is typically the local host name.
(You can change these settings later within 3DM.)
SCSI
Figure 11. 3DM E-mail Notification Preferences
7
8
Continue with the installation as prompted, clicking Next to move to the
next screen, and Finish when you reach the last screen.
3DM Installation gives you the option of starting 3DM and opening the
browser window.
If you elect to launch the web interface, a Security Alert may appear, as
shown in Figure 12. Click Yes continue.
You may install the certificate if you do not want to see this alert in the
future. To do so, click View Certificate and then click Install Certificate.
Figure 12. Security Alert dialog box
9
When the first 3DM screen appears in your browser, log in as
Administrator and use the default password, 3ware.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Notes:
You can start 3DM later by choosing 3DM from the Start menu.
If you change, add, or remove an IP address, or change the
machine name of the machine on which you have installed 3DM 2,
you will need to recreate the security certificate. You can do so by
re-installing 3DM 2, or by deleting the file 3dm2.pem and
restarting the 3DM 2 service. Under Windows, this file is located
in the same directory in which you installed 3DM 2. Under Linux,
the file resides in /etc/3dm2. You may also want to delete the
installed/cached security certificate from your browser.
Uninstalling 3DM under Microsoft Windows
Use the Add or Remove Programs control panel to uninstall 3DM.
■ From the Startup menu, choose Control Panels > Add or Remove
Programs.
■ In the Add or Remove Programs control panel, select 3DM and click
Change/Remove.
Installing 3DM for Linux or FreeBSD
You can install 3DM from the command line, or from a GUI. The steps below
describe how to install 3DM from the command line. If you are using a GUI,
you can access the CD-ROM and folders from the windows in the GUI.
Note: If you downloaded 3DM_Linux.zip from the website, unzip
the file to root (or to any other working directory) and change
Directory (CD) to that directory (for example: /root). Then start
the following procedure at step 3, substituting /mnt with /rootor
your installation directory.
To start the installation
1
2
3
Insert the 3ware software installation CD-ROM for Linux into the CD-
ROM drive.
Mount the CD-ROM disk:
mount /dev/cdrom /mnt
Change the directory and run the install script:
For Linux:
cd /mnt/packages/3dm2/linux/x86
./install.3dm
For FreeBSD:
cd /mnt/packages/3dm2/freebsd/x86
./install.3dm
32
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing 3DM
To specify initial setup for 3DM 2
During installation, you will be prompted with a series of questions that
determine initial 3DM settings. You can change these later, from within 3DM.
(The first question appears for Linux, but not for FreeBSD.)
1 Was RPM used to install the Escalade driver and/or 3DM?
The default answer is no.
2 Please enter the location of the help documentation (default
is /usr/local/doc/3dm)
Press Enter to accept the default location and display the next question, or
enter the path at which you want the documentation to be installed.
3 Would you like to have e-mail notification enabled (Y/N)?
E-mail notification sends an email message when an event occurs.
The default answer to this question is “yes”.
If you enable e-mail notification you will be asked to provide additional
information: the name of the mail server, the user name for the person
who will send the E-mail notification (typically the local host name) and
the user name for the person who will receive the e-mail notification
(typically the system administrator).
Please enter the name of your mail server: (default is local
host name)
Please enter the name of the user you want sending e-mail
notification: (default is root)
Please enter the name of the user you want receiving e-mail
notification: (default is 3ware_admin)
To enter multiple e-mail addresses, separate them by a comma or a
semicolon:
4 Please enter the port number you would like to use for web
monitoring (default is 888)
If you do not know what port to use, select the default:
5 Would you like 3DM connection security to limit connections
to localhost only? (default is yes)
If you want to be able to use 3DM for remote administration, change this
to No.
6
Change the directory and then eject the CD-ROM disk when finished:
cd /home
eject cdrom
33
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Uninstalling 3DM under Linux or FreeBSD
To uninstall 3DM for Linux or FreeBSD
1
2
Insert the 3ware software installation CD-ROM into the CD-ROM drive.
Mount the CD-ROM disk:
mount /dev/cdrom /mnt
3
Change the directory and run the uninstall script:
(For FreeBSD, replace “linux” with “freebsd” in the path shown in this
step.)
cd /mnt/packages/3dm2/linux/x86
./install.3dm --u
Note that if you downloaded 3DM from the web, replace “/mnt/” in the
previous command with “/root/”
4
Eject the CD-ROM disk when finished:
cd /home
eject cdrom
Note: If 3DM Linux is reinstalled or restarted, close any open
web browsers before starting 3DM again to close the server
socket.
34
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Starting 3DM and Logging In
Starting 3DM and Logging In
3DM runs as a service under Windows, and as a daemon under Linux.
It is a good idea to leave 3DM running on the system that contains your 3ware
RAID controller. That way email alerts can be sent by 3DM, and
administrators can manage the controller remotely, if remote administration is
enabled.
You can access the 3DM screens to check status information and manage your
3ware RAID controller by logging in to the 3DM screens in your browser.
Starting 3DM under Linux
3DM should start automatically after installation and upon bootup.
To start 3DM manually
1
1
Login as root.
Afterwards, type:
For Red Hat Linux:
/etc/rc.d/init.d/3dm start
For SuSE Linux:
/etc/rc.d/3dm start
2
Open your browser and enter the URL for your system.
You can also replace “localhost” with the IP address of the computer that
The 3DM login screen appears.
Starting 3DM under Windows
■ From the Start menu, choose Programs > 3ware > 3DM 2.
Your default browser opens and displays the URL for your local
controller.
You can also replace “localhost” with the IP address of the computer that
contains the 3ware controller. For example:
35
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Note: If you close your browser, 3DM continues to run in the
background on the system.
Viewing 3DM Remotely via a Standard Web Browser
When remote administration is enabled, you can use 3DM to check status and
administer your 3ware RAID controller from a browser on any computer, over
an internet connection.
You do not need to install the 3DM software on the remote computer.
Remote connections can be enabled or disabled from the 3DM Settings page.
■ In the address line of your browser, enter the URL or IP of the system
containing the 3ware RAID controller.
If you don’t know the URL or IP for the system, you can contact your
network administrator or from a Windows command prompt, type
ipconfig. From a Linux command prompt, type ifconfig.
Logging In
When you first view 3DM in a browser, you must log in before you can view
or change any information.
Two levels of access are provided:
■ Users can check the status of the controller, units, and drives attached to
it.
■ Administrators can check status, configure, and maintain the equipment.
(Administrator and User status in 3DM is not related to Administrator/User
settings in the operating system.)
To log in to 3DM
1
On the 3DM logon screen, select whether you are a User or
Administrator.
2
Enter your password and click Login.
If you are logging in for the first time after installing 3DM, the default
password for both User and Administrator is 3ware.
Note: If you forget the passwords, uninstalling and reinstalling
3DM resets the passwords to 3ware.
36
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Working with the 3DM Screens
Working with the 3DM Screens
3DM’s features are organized on a series of pages you view in your browser.
After you log in to 3DM, the Summary page shows a list of controllers
installed in the computer at the URL you specified.
Note: If you expect to see a controller that is not listed, it may not
be compatible with the driver that is loaded; a firmware flash
upgrade may be required.
Figure 13. 3DM Main Screen
The menu bar across the top of the screen gives you access to other pages in
3DM. You can move between pages by using the menu bar, or by clicking a
link on the page.
The main area of the page provides summary or detail information about your
3ware RAID controller and the resources connected to it.
As you work in 3DM, the Messages area just below the menu bar displays
information about the results of commands you have selected.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
3DM Menus
The 3DM menu bar groups access to a number of 3DM pages on menus, and
provides direct link access to others.
Figure 14. 3DM Menu Bar
Status information is available from the Information menu. You can view
controller, unit, and drive information for a particular controller.
The Management menu gives you access to tasks used for managing
controller-level settings (background task rate, enabling of unit write cache,
and policies that affect all units managed by the controller), tasks that can be
scheduled (rebuild, verify, and self-test), and maintenance of individual units.
Unit configuration can also be done through the Management > Maintenance
page.
The Alarms page shows a list of alarms, including the specific alarm
message, and the exact date and time it occurred.
The 3DM Settings page lets you set preferences, including email notification
for alarms, passwords, page refresh frequency, whether remote access is
permitted, and the incoming port which 3DM will use for listening.
Help lets you access information about using 3DM, and provides access to an
electronic copy of this User Guide.
38
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Working with the 3DM Screens
Viewing Information About Different Controllers in
3DM
If you have more than one controller in the system, you select the one you
want to see details about from the drop-down list at the right of the menu bar.
This drop-down is available on all pages that provide controller-specific
features.
Note: Throughout these instructions, current controller is used to
refer to the controller which is currently selected in this drop-down
list.
Refreshing the Screen
You can refresh the data on the screen at any time by clicking Refresh Page
in the menu bar. This causes 3DM to update the information shown with
current information from the controller and associated drives.
Automatic refreshes can also be set. For details, see “Setting the Frequency of
Note: If you click Refresh on the browser window, you will be
taken back to the Summary page.
3DM Screens and What They're Used For
Table 5 shows a list of the pages you work with in 3DM and describes what
they are used for. Details about each page and the fields and features on it are
Table 5 provide links to details about that page.
Table 5: List of 3DM Pages
3DM Page
Description
Provides basic information about each 3ware RAID
controller in your system.
To see this page, click Summary in the menu bar.
Provides detailed information about the current
controller.
To see this page, choose Information > Controller
Details from the menu bar.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Table 5: List of 3DM Pages
3DM Page
Description
provides summary information about each unit.
To see this page, choose Information > Unit
Information from the menu bar or click an ID number
on the Controller Summary.
Shows details about a particular unit.
To see this page, click an ID number on the Unit
Information page.
Shows a list of drives on the current controller and
provides summary information about each drive.
To see this page, choose Information > Drive
Information from the menu bar.
SMART Details About
Drive at Particular
Shows the SMART data for a specific drive.
To see this page, click the Port # for a drive on the Drive
Information page.
Lets you view and change settings that affect the units
on the current controller.
To see this page, choose Management > Controller
Settings from the menu bar.
Lets you view and change the schedule for tasks that
affect all units on the current controller.
To see this page, choose Management >
Scheduling from the menu bar.
Lets you configure new units and make changes to
existing units.
To view this page, choose Management >
Maintenance from the menu bar.
Shows a list of alarms, including the specific alarm
message, and the exact date and time it occurred.
To view this page, click Alarms on the menu bar.
Lets you set preferences, including email notification for
alarms, passwords, page refresh frequency, whether
remote access is permitted, and the incoming port which
3DM will use for listening.
To view this page, click 3DM Settings on the menu
bar.
40
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Up 3DM Preferences
Setting Up 3DM Preferences
The 3DM Settings page lets you define preference settings that affect the
overall operation of 3DM. Most of these settings are specified initially during
installation of 3DM.
On the 3DM Settings page you can perform the following tasks:
Setting and Changing 3DM Passwords
3DM provides different access levels for users and administrators.
The Administrator access level allows the user to fully configure 3DM. The
User access level allows the user to view pages within 3DM. These passwords
work independently of each other.
The default password for both the User and Administrator is “3ware”.
Passwords are case sensitive.
You can only change passwords if you are logged in as Administrator. If you
change the Administrator password, you will be automatically logged out, and
must log back in with the new password.
To set or change the password
1
2
Click 3DM Settings on the 3DM menu bar.
On the 3DM Settings page, in the Password section, select the type of
password you want to change: User or Administrator.
3
Type the current password in the Current Password field.
If you are changing the password for the first time, the factory-set default
password is 3ware.
4
5
Enter the new password in the New Password field and again in the
Confirm New Password field.
Click the Change Password button to enact the change.
Note: If you forget your password, you can uninstall 3DM and then
reinstall it. This will reset the password to the default password,
3ware.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Managing E-mail Event Notification
3DM can notify you when the 3ware RAID controller requires attention, such
as when a disk unit becomes degraded and is no longer fault tolerant.
Event notification can only occur while 3DM is running, so it is
recommended that 3DM be left running on the system that contains the 3ware
RAID controller.
When events occur, notification can be e-mailed to one or more recipients.
You can specify the type of events for which notifications will be sent by
selecting the severity:
■ Information will send e-mails for all alarms
■ Warning will send e-mail for alarms with severity of Warning and Error
only.
■ Error will send e-mail for alarms with severity of Error only.
For more information about events and alarms, see “Viewing Alarms” on
Event notification is initially set up during 3DM installation, but can be
changed on the 3DM Settings page.
To set up event notification
1
2
Click 3DM Settings on the menu bar.
In the E-mail Notification section of the 3DM Settings page, enter or
change the settings you want.
■ Enable or Disable all notifications.
■ Set the severity level of events for which e-mail notifications are sent.
■ Specify the email address of the sender. This will appear in the
“From” field of the e-mail.
■ Enter the e-mail address(es) to which notifications are sent. (Separate
multiple addresses with a comma (,) or a semicolon (;).
■ Enter the SMTP server name or IP of your mail server.
Click Save E-mail Settings.
3
To send a test message
You can send a test message to make sure you’ve entered the e-mail
notification settings correctly.
■ Click Send Test Message.
42
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Up 3DM Preferences
Enabling and Disabling Remote Access
When remote access is enabled, a user can connect to 3DM over the internet
or an intranet, to check status or administer the controller and associated
drives.
If remote access is disabled and a user attempts to connect to 3DM remotely,
they will see the following error message: “Remote Access to 3DM has been
disabled. Please connect using the local machine by entering “localhost” in
the URL bar.”
Remote access can be enabled or disabled on the 3DM Settings page.
To enable or disable remote access
1
2
Click 3DM Settings on the menu bar.
In the Remote Access section of the 3DM Settings page, select either
Enabled or Disabled in the Allow Remote Connections field.
The page refreshes, and a message at the top of the screen confirms that
remote access has been enabled or disabled.
Setting the Incoming Port #
You can set the port which 3DM uses to listen for incoming messages. If you
are not sure which port would be the best to use, leave this set to the default
port of 888.
To set the incoming port
1
2
Click 3DM Settings on the menu bar.
In the Incoming Port # section of the 3DM Settings page, enter the port
number in the Listening Port field.
The page refreshes, and a message at the top of the screen confirms that
the listening port has been changed.
Setting the Frequency of Page Refreshes
Since the status of the drives attached to your 3ware RAID controller can
change while you are viewing information about them in 3DM, it’s important
to refresh the page information regularly. That way you can be assured that
the information you see in 3DM is current.
You can manually refresh the information on a page by clicking Refresh Page
in the menu bar. But you can also have 3DM refresh the information on a
regular basis.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
To set the frequency of page refreshes
1
2
Click 3DM Settings on the menu bar.
In the Page Refresh section of the 3DM Settings page, select how often
you want the page to be refreshed in the Minutes Between Refresh field.
Note: If you don’t want 3DM to refresh the screen automatically,
select Never in the Minutes Between Refresh field. You can then
refresh manually by clicking Refresh on your web browser.
Running Two Versions of 3DM
Although you can view information about 7000- and 8000-series controllers
in 3DM 2, some features of version 2 are only available for the 9000-series,
because they require that the firmware contain associated capabilities. When
this is the case, a message appears in the 3DM page indicating that the feature
is not available for the current controller.
The scheduling feature is one that works differently in 9000-series controllers
and earlier controllers. If you want to set the schedule for background tasks
for a 7000- or 8000-series controller, you must do so by using 3DM version
1.x.
If you have multiple controllers in the same system, and the controllers are
from different series, it is possible to install and run both 3DM 2 and 3DM
version 1.x on the same system.
Note: If two different versions of 3DM are both running, they have
to be listening on different ports.
In addition, alarms cannot be captured by both versions.
44
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
3DM 2 Reference
This section includes details about the fields and features available on the
pages you work with throughout 3DM 2. It is organized by page, as the pages
are organized on the 3DM menu bar.
Controller Summary Page
Figure 15. Controller Summary Page
Note: The software version shown in the screenshots in this
manual are preliminary examples only. For the current released and
tested version number, refer to the 9000 release notes.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
The Summary page appears after you first logon to 3DM, and when you click
the Summary link in the menu bar.
The Summary page provides basic information about each 3ware RAID
controller in your system. To see details about the units in a controller, click
the link in the ID column.
ID. The ID that the operating system assigns to the controller.
Note: The controller ID you see in 3DM 2 may not match the
number that you see for the same controller in 3DM version 1.x.
Model. The model name of the controller. (The model number is also printed
on a sticker on the outside bracket of the controller.)
Serial #. The serial number of the controller. (The serial number is also
printed on a sticker on the outside bracket of the controller.)
Firmware. The firmware version running on the controller.
Driver. The driver version being used to interact with the controller.
Status. The overall status of the controller. Possible statuses include OK,
Warning, Error, and No Units. Warning indicates that a background task is
currently being performed (rebuilding, verifying, or initializing). Error
indicates that a unit is degraded or inoperable. If both Error and Warning
conditions exist, the status will appear as Error.
46
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Controller Details Page
Figure 16. Controller Details Page
The Controller Details page appears when you choose Information >
Controller Details from the menu bar.
The Controller Details page provides detailed information about the controller
specified in the drop-down list on the menu bar.
You can also open or download an error log from this screen.
Model. The model name of the controller.
Serial #. The serial number of the controller.
Firmware. The firmware version running on the controller.
Driver. The driver version being used to interact with the controller.
BIOS. The BIOS version on the controller.
Monitor. The Monitor version on the controller.This field appears only for
7000- and 8000-series controllers.)
Boot Loader. Boot Loader version on the controller. This field appears only
for 9000-series controllers.
# of Units. The number of units on the controller.
# of Ports. The number of total ports on the controller, regardless of whether
each currently has a drive connected.
Error Log. Provides access to the firmware’s error log. When you click this
link, a dialog box gives you the option to save the log to your computer, or
open it.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Unit Information Page
Figure 17. Unit Information Page
The Unit Information page appears when you choose Information > Unit
Information from the menu bar, and when you click an ID number on the
Controller Summary page.
The Unit Information page shows a list of the units on the controller specified
in the drop-down list on the menu bar and provides summary information
about each unit.
To see details about a particular unit, click the link in the Unit # column.
Unit #. The unit number assigned to the unit by the firmware. For 9000-series
controllers, unit numbers are in sequential order. For 7/8000-series
controllers, unit numbers begin with the lowest port number.
Type. The type of unit, specified during configuration: RAID 0, RAID 1,
RAID 5, RAID 10, RAID 50, Single Disk, JBOD, or Spare. For details about
each of the RAID levels, see “Understanding RAID Concepts and Levels” on
Capacity. The logical capacity (size) of the unit.
48
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Note: 3DM 2 displays the capacity (in MBytes or GBytes) the
same way that Microsoft Windows and Linux operating systems
do: as 1KB = 1024 bytes. Previous versions of 3DM 1.x used the
1KB = 1000 bytes definition. Consequently capacities of units
listed under 3DM v 1.x may appear to be larger than they do under
3DM 2.
Status. The operational status of the unit: OK, Rebuilding, Initializing,
Verifying, Degraded, or Inoperable (missing drives). When a unit is
Rebuilding, Initializing, or Verifying, the percentage (%) complete is also
shown.
Unit Details Page
Figure 18. Unit Details Page
The Unit Details page appears when you click an ID number on the Unit
Information page. Because it is a sub-page of Unit Information, the page title
in the menu bar continues to display “Unit Information” even when you view
details of a unit. To return to the list of units, click Unit Information in the
menu bar.
The Unit Details page shows details about a particular unit. The specific
information shown depends on what type of unit it is. For example, details
about a RAID 10 unit made up of two subunits, each of which contains two
drives, will include details about the unit and each subunit, as shown in
49
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Figure 18. However, if the unit was a Single Disk, only information about one
disk would be shown.
Details on this page may include all or some of the following information
described below.
To see details about a particular drive, click the Port #. You’ll see a list of all
drives, with the drive you selected highlighted.
Status. The operational status of the unit or subunit: OK, Rebuilding,
Initializing, Verifying, Degraded, or Inoperable (missing drives). When a unit
is Rebuilding, Initializing, or Verifying, the percentage (%) complete is also
shown.
Capacity. The total capacity of the unit (capacities of subunits are not shown).
Type. The type of unit or subunit it is. RAID 0, RAID 1, RAID 5, RAID 10,
RAID 50, Single Disk, Spare, JBOD, or Disk
Stripe. The stripe size of the unit, if applicable.
Subunits. If the unit has subunits, details of the subunits are shown.
Port #. If the Type is Disk, Single Disk, JBOD, or Spare, the port to which the
drive is connected is shown. For multiple drive units, the port numbers are
shown in the subunits section. The port number is a link to the Drive
Information page.
50
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Drive Information Page
Figure 19. Drive Information Page
The Drive Information page appears when you choose Information > Drive
Information from the menu bar, or when you click a port # on the Unit
Details page. If you arrive at this page from the port # hyperlink on the Unit
Information page, the line showing the port # you clicked on is highlighted.
The Drive Information page shows a list of drives on the controller specified
in the drop-down list on the menu bar, and a summary of each one.
To see the SMART data for a drive, click the link in the Port # column.
Port #. The port to which the drive is connected.
Model. The model of the drive.
Capacity. The physical capacity of the drive. (Note that the capacity as shown
on 3DM screen is calculated as 1KB = 1024. This amount may differ from the
capacity that is printed on the disk drive, where it typically has been
calculated as 1K = 1000. Consequently, the capacity of the drive may appear
smaller in the 3DM screens. No storage capacity is actually lost; the size has
simply been calculated differently for consistency.
Serial #. The serial number of the drive.
Firmware. The firmware version of the drive.
Unit. The unit the drive belongs to, if applicable.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Status. The status of the drive: OK, Not Supported, Read Timeout, Read
Failure, Orphan, DCB Data Check, Unsupp DCB, Unconv DCB, Offline
JBOD, or Not Present. (In the event of a problem, the status shown for the
drive can be useful to customer support.)
Note: In most cases, the status of the drive will not correspond to
the status of the unit, shown on the Unit Information page.
SMART Details About Drive at Particular Port Page
Figure 20. S.M.A.R.T Data Page
The SMART Details page appears when you click a Port # on the Drive
Information page.
SMART data is displayed as hex values.
Consult your disk drive manufacturer for information on how to interpret the
SMART data. The SMART data meaning varies by disk drive manufacturer
and model.
52
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Controller Settings Page
Figure 21. Controller Settings Page
The Controller Settings page appears when you choose Management >
Controller Settings from the menu bar.
The Controller Settings page lets you view and change settings that affect the
units on the controller specified in the drop-down list on the menu bar.
Background Task Rate
The Background Task Rate fields let you change the balance of background
tasks (rebuild and verify) and I/O performed by the controller.
9000-series controllers show separate settings for Rebuild Rate and Verify
Rate, as shown in Figure 21. 7000- and 8000-series controllers show only one
setting for Task Rate; it applies to both rebuild and verify rates.This rate is not
persistent following a reboot for 7/8000.
The 5 radio buttons let you set the ratio at which rebuilds and verifies are
performed. The furthest left buttons set the firmware to the fastest rebuild and
verify settings. This means, maximum processing time will be given to
rebuilds or verifies rather than I/O. The furthest right buttons set the firmware
to the slowest rebuild and verify settings, giving maximum processing time to
I/O.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
For additional information, see“Setting Background Task Rate” on page 113.
Unit Write Cache
You can enable or disable write cache for each unit.3DM lists each unit on the
controller specified in the drop-down list on the menu bar, and shows you
whether the write cache is currently enabled or disabled for it.
Write cache is a combination of the physical hard drives’ write cache as well
as the controller’s memory, depending on what type of unit you are using.
For 9000-series controllers, a Disable Write Cache on Unit Degrade setting
can be set in 3ware BIOS Manager (3BM). You can see if this setting is
enabled in the Other Controller Settings field at the bottom of this
Controller Settings page. If Disable Write Cache on Unit Degrade is
enabled, upon degrade of a unit, the write cache will automatically be
disabled, even if you enable write cache in the Unit Write Cache field.
For additional information, see “Enabling and Disabling the Unit Write
Unit Policies
For units on 9000-series controllers, you can enable or disable two policies:
Auto-verify and Continue on Source Error During Rebuild. 3DM lists
each unit on the controller specified in the drop-down list on the menu bar,
and shows you whether the policies are currently enabled or disabled for each
unit.
This section does not appear for 7000- and 8000- series controllers.
Auto-verify. The Auto-verify policy causes verify tasks to be performed
repeatedly during a scheduled verify window. When Auto-verify is disabled,
verify is not initiated automatically by the controller. Verify can still be started
manually with 3DM, 3BM, or CLI. Once a manually-started verification is
complete, no further verify tasks for the unit is performed.
Continue on Source Error During Rebuild. This policy applies only to units
which are redundant. (For units which are not redundant, a check box is not
available.) When this policy is set, ECC errors are ignored when they are
encountered during a rebuild. When this policy is not set, a rebuild will abort
upon encountering an ECC error and the unit will be set back to Degraded.
Since this option could result in the loss of some source data in the event of
source errors, select this option only if you want to ensure that a rebuild will
complete successfully without manually intervention. If the rebuild fails and
Continue on Source Error During Rebuild is not selected, then you have
the option to start a rebuild manually. It is recommended that a file system
check be executed when the rebuild completes.
54
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Note: The policy Continue on Source Error During Rebuild is
equivalent to the “Force continue on source errors” option in 3DM
v 1.x and the “ignoreEcc” option in the CLI.
Other Controller Settings
For 9000-series controllers, the Other Controller settings displays information
about additional settings that can only be changed in the BIOS (3BM). For
more information see “Setting Policies for a Controller through 3BM” on
This section does not appear for 7000- and 8000- series controllers.
Number of Drives Per Spin-up. Number of drives that will spin up at the
same time when the controller is powered up. (This setting only applies when
the feature is supported by the disk drives and has been enabled in 3BM.)
Delay between Spin-ups. The delay between drive groups that spin up at one
time on this particular controller.
Export JBOD (Unconfigured) Disks. Indicates whether unconfigured disks
(JBODs) should be exported to the operating system. By default, this setting
is disabled. For more information about this feature, see “Exporting JBOD
Disable Write Cache on Unit Degrade. Indicates whether write cache will
be automatically disabled on a unit if it becomes degraded. After the unit is
rebuilt, the write cache will be re-enabled automatically.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Scheduling Page
Figure 22. Scheduling Page
For 9000-series controllers, the Scheduling page appears when you choose
Management > Scheduling from the menu bar.
The Scheduling page is not available for 7000- and 8000- series controllers. If
you want to schedule tasks for one of those controllers, use 3DM Version 1.x.
56
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
The Scheduling page lets you view and change the schedule for tasks that
affect all units on the controller specified in the drop-down list on the menu
bar, including:
■ Rebuild tasks (also applies to initialization tasks)
■ Verify tasks (also applies to media scans)
■ Self-tests
You can also enable or disable use of the schedule for Rebuild and Verify
tasks by selecting either Follow Schedule or Ignore Schedule. When these
schedules are set to be ignored, these tasks can be performed at any time, and
are not restricted to the scheduled times.
Note: Scheduling of these tasks is only available on the 9000-
series controllers.
For details about the different background tasks, see “About Background
About Task Schedules
Each type of task may be scheduled for up to 7 times per week. This limits
active initializing, rebuilding, verifying, and testing of a unit to the times you
specify, so that the task does not interfere with peak I/O times.
If all 7 schedule slots are filled, you must first remove one or more schedule
times before you can add another.
You may set schedule times whether scheduling is set to be followed or
ignored. This is useful if you want to temporarily disable the schedule.
If you remove all the schedule times for a particular background task,
initializations and rebuilds will run anytime, as they are needed. Verify will
only run if started by the CLI or if the Verify Unit button is clicked.
For information about adding and removing schedules, and setting schedules
to be followed or ignored, see “Scheduling Background Tasks” on page 114
About Self-tests
Unlike scheduling of rebuilds and verifies, scheduling of self-tests is always
followed. To disable self-tests you either remove all schedule times, or
uncheck the tests listed in the Tasks column.
Note: Only the checked tasks will be run during the scheduled
times. If none of the tasks are checked, self-tests will never run,
even if you have scheduled time slots set.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Two self-tests can be scheduled:
Upgrade UDMA mode. This test checks the speed at which data transfer to
drives is occurring, to see if the UDMA mode can be increased. (If you are
already running at the fastest UDMA mode, then this self-test has no effect.)
The UDMA mode can become downgraded in the event that cable CRC errors
are encountered, requiring multiple retries to read sectors. In severe cases, the
UDMA mode may be downgraded from ATA 150 to ATA 133, to ATA 100, to
66, to 33.
This check is also done every time the system is booted.
UDMA mode does not apply to SATA.
Check SMART Thresholds. This test checks to see whether SMART
thresholds have been exceeded.
The SMART thresholds indicate when a drive is likely to fail, based on the
number of errors that have been recorded through SMART (Self-Monitoring,
Analysis and Reporting Technology).
If any of the disk drives have detected a “threshold exceeded” condition, then
an AEN is logged to the 3DM Alarms page. Moreover, if anything unusual is
found during any self-test, it will be logged as an Alarm.
58
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Maintenance Page
Figure 23. Maintenance Page
The Maintenance page appears when you choose Management >
Maintenance from the menu bar.
The Maintenance page lets you perform maintenance tasks on existing units
on the current controller (shown in the drop-down list on the menu bar), and
lets you create new units by configuring available drives.
Rescan Controller
Use the Rescan Controller button to have 3DM scan the available drives in
the controller and update the list of available drives shown. This is useful in
variety of maintenance tasks. For example, if you physically plug in a drive
and want the controller to recognize the newly plugged in drive.
Note: If you unplug a drive without first removing it through 3DM,
Rescan will not recognize it as gone unless the drive was in use or
until it is required by the system. Always use the Remove link to
remove a drive before unplugging it.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Warning: Removing or adding drives which are not in hotswap
carriers can result in a system hang or may even damage the system
and the drive.
In 9000-series controllers, rescan checks empty ports for newly plugged in
drives. If those drives were previously part of a 3ware RAID configuration
and they still have valid DCB (Disk Configuration Block) information on
them, the controller tries to piece them back together into a working unit. If a
working unit can be formed, it will appear in the Unit Maintenance list when
the scan is complete, and the operating system will be notified of the unit. In
Linux or FreeBSD, a device node will be associated with each unit created. In
Windows the device manager will reflect the changes under the disk drives
icon. This process is known as importing drives.
If new drives do not have any data indicating they were previously part of a
3ware RAID configuration, they will appear in the Available Drives list.
In addition, if there is a unit with the status Inoperable before a rescan (for
example, a RAID 5 unit missing 2 or more drives), and a rescan finds drives
that complete the unit, the inoperable unit will become a valid unit.
Note: In 8000-series controllers, only JBOD units can be removed
and rescanned while keeping the data intact. Clicking Rescan
Controller after removing units other than a JBOD unit (e.g.
RAID 5) will cause the drives that make up the unit to be
seen as individual available drives; they will not be pieced
together to form a unit. This is unlike the 9000 series
controllers, which will piece together the unit for you and
display the drives as a unit. If you still want to use the drives
together as a unit, restart the computer before creating a new
unit with those drives. Creating a new unit with those drives
will destroy any existing data on them. After you restart, the
8000 will again see the drives as a valid unit.
Unit Maintenance
The Unit Maintenance section of the page lists all existing units on the current
controller, and displays summary information about them.
The top row shows information about the unit, while subsequent rows show
summary information about each drive in the unit.
Unit Information
Unit Number. The unit number assigned to the unit by the firmware. Unit
numbers for 9000 series are in sequential order. Unit numbers for the 7/8000
series will begin with the lowest port number of the unit. Use the checkbox
next to the unit to select a unit before clicking one of the task buttons.
60
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
# Drives. Number of drives in the unit.
Type of Unit. Type of unit specified during configuration: RAID 0, RAID 1,
RAID 5, RAID 10, RAID 50, Single Disk, Spare, or JBOD.
Capacity. The usable capacity (size) of the unit.
Status. Operational status of the unit: Ok, Rebuilding, Initializing, Verifying,
Degraded, or Inoperable (missing drives). When Rebuilding, Initializing, or
Verifying, the percentage (%) complete is also shown. The % complete can be
active or paused. To see whether this task is currently active or paused, click
on the unit number to display the Unit Information page, which has that
information.
Drive Information
Port. The port to which the drive is connected.
Model. The model of the drive.
Capacity. The capacity (size) of the drive.
Status. The status of the drive: OK, Not Supported, Not Present, and so forth.
If you need help regarding a status displayed here, please contact Technical
Support.
Remove Drive. The Remove Drive link removes a drive from the controller
so that you can safely unplug it. In the Unit Maintenance section, this link is
only provided for drives that can be safely removed without creating an
inoperable unit. (For example, a RAID 5 missing 2 or more drives or a RAID
0 missing 1 or more drives would become inoperable.) If you remove a drive
from a redundant unit, the unit will become degraded. Once a unit has become
degraded, additional drives cannot be removed without making it inoperable,
so no Remove Drive link will display.
Warning: Physically removing drives which are not in hotswap
carriers can result in a system hang or may even damage the system
and the drive.
Maintenance Task Buttons
Below the list of units, a row of task buttons lets you preform maintenance
and configuration tasks related to the unit. Before clicking one of these
buttons, select the appropriate unit.
Verify Unit. Puts the selected unit in verifying mode. If verify scheduling is
enabled on the Scheduling page, the unit will not start actively verifying until
the scheduled time, and the status will indicate “Verify-Paused.” (The Unit
Details page will indicate whether a unit is actively verifying.) If verify
scheduling is not enabled, clicking Verify Unit begins the verification
process.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
If the unit you selected to verify is a redundant unit, the redundancy of the unit
will be verified. For example it will check parity for a RAID 5 or check data
consistency for a RAID 1. If the unit you checked is not a redundant unit,
verify will do a surface scan of the media. During verification, I/O continues
normally. For RAID 0, single disks, JBODs, and spares, there is only a slight
performance loss. For redundant units, you can set the background task rate
on the Controller Settings page to specify whether more processing time
should be given to verifying or to I/O.
While a unit is verifying, the status changes to Verifying and a Stop Verify
link appears in the right-most column of the Unit Maintenance table.
Note: If the unit has not previously been initialized and you click
Verify Unit, the initialization process starts. Initialization cannot
be halted, so no Stop Verify link appears. (Initialization can be
paused, however, through Scheduling. Initialization follows the
Rebuild schedule, so turning on scheduling for Rebuild will pause
initialization, as well.) For more information about initialization,
Rebuild Unit. Replaces a degraded drive in a degraded unit with an available
drive and begins rebuilding the RAID. When you select a degraded unit and
click Rebuild Unit, a dialog box listing available drives appears, so that you
can select the drive you want to use. If the degraded unit has more than one
degraded drives (for example, a RAID 10 where both mirrored pairs each
have a degraded drive), you will repeat this process a second time.
If rebuild scheduling is enabled on the Scheduling page, the unit will not start
actively rebuilding until the scheduled time, and the status will change to say
“Rebuild-Paused.” (The Unit Details page indicates whether a unit is actively
rebuilding.) If rebuild scheduling is not enabled, the rebuild process will
begin right away.
Remove Unit. Removes a selected unit and allows you to unplug the drives
and move the unit to another controller. the data on the unit remain intact.
62
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Caution: Before you click Remove Unit, make sure the unit you
are removing is unmounted and no I/Os are being issued. (For
example, make sure you are not copying files to the unit, and make
sure that there are no applications with open files on that unit.)
If a unit is not unmounted and you remove it, it is the equivalent of
physically yanking a hard drive out from under the operating sys-
tem. Resulting behavior depends on which operating system you
are using and what kind of I/O is being done, however you will
typically see really bad results, bad errors, and most likely a reset
of the controller or a system hang.
To unmount a unit under windows, use Administrative Tools >
Computer Management > Disk Management. In the Computer
Management window, right-click on the partition and Remove the
logical drive letter associated with the unit.
To unmount a unit under Linux, unmount the mount point to where
the RAID unit is mounted. For example, if you want to remove unit
0 and you know that 0 corresponds to /dev/sdb, you should
unmount all partitions for sdbx (where x is the number of the parti-
tion).
umount /dev/sdbx
For FreeBSD, the command would be
umount /dev/twedx
When you click Remove Unit, you will be asked to confirm that you want to
proceed. When you confirm the removal, the unit number and information
will be removed from 3DM. (Units created in the future can reclaim this unit
number.)
The operating system is notified that the unit was removed. In Linux the
device node associated with this unit is removed. In Windows the Device
Manager will reflect the changes under the disk drives icon.
Information about the unit remains intact on the drives. This allows the drive
or drives to be reassembled into a unit again on this controller, or if moved to
another controller.
Warning: Physically removing drives which are not in hotswap
carriers can result in a system hang or may even damage the system
and the drive.
Delete Unit. Deletes the selected unit and allows you to use the drives to
create another unit. The drives appear in the list of Available Drives.
63
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Caution: Before you click Delete Unit, make sure the unit you are
removing is unmounted and no I/Os are being issued. If a unit is
not unmounted and you delete it, it is the equivalent of physically
yanking a hard drive out from under the operating system.
Resulting behavior depends on which operating system you are
using and what kind of I/O is being done, however you will
typically see really bad results, bad errors, and most likely a reset
of the controller or a system hang.
Devices can be unmounted through the operating system. For
details, see the discussion under Remove Unit, above.
Warning: When a unit is deleted, the data will be permanently
deleted: the drives cannot be reassembled into the same unit. If you
want to reassemble the drives on another controller and access the
existing data, use Remove Unit instead of Delete Unit.
After deletion, the operating system is notified that the unit was deleted. In
Linux the device node associated with this unit is removed. In Windows the
Device Manager will reflect the changes under the disk drives icon.
Available Drives (to Create Units)
This section lists the drives on the controller which are not currently
configured as part of a unit. The Port number, model, capacity, and status are
all displayed, as they are for drives in existing units.
Remove Drive. The Remove Drive link removes a drive from the controller
so that you can safely unplug it. Any drive in the Available Drives list can be
removed.
Warning: Physically removing drives which are not in hotswap
carriers can result in a system hang or may even damage the system
and the drive.
Create Unit
Use the Create Unit button to create a unit for use on the current controller.
Begin by selecting the drives you want to use in the list of Available Drives,
and then click Create Unit. You will be prompted to select the unit Type,
Stripe size (if applicable), Write Cache, and Auto Verify settings.
A window like the one in Figure 24 shows the drives you selected, and lets
you specify configuration settings.
64
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Figure 24. Configuring a Unit in 3DM
For more detailed instructions, see “Creating a Unit through 3DM” on
Type. The drop-down list lists the possible RAID configurations for the drives
selected in the list of Available Drives. Available configurations may include
RAID 0, RAID 1, RAID 5, RAID 10, RAID 50, Single Disk, and Spare Disk.
For information about these configurations, see “Available RAID
When you are configuring a RAID 50 with twelve drives, an additional field
appears, in which you select the number of drives per subunit—3, 4, or 6.
Figure 25. Configuring a RAID 50 with 12 Drives
Stripe. The drop-down list of stripe sizes lists the possible stripe sizes for the
configuration you selected in the RAID level drop-down.
The default stripe size of 64KB will give the best performance with
applications that have many sequential reads and writes. A larger stripe size
will give better performance with applications that have a lot of random reads
65
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
and writes. In general, the smaller the stripe size, the better the sequential I/O
and the worse the random I/O. The larger the stripe size, the worse the
sequential I/O and the better the random I/O.
Write Cache, Auto-Verify, and Continue on Source Error during Rebuild.
These check boxes let you set the policies for the unit. These policies can also
be set and changed on the Controller Settings page. For details about these
Note: If the configuration window disappears while you are
selecting drives, 3DM 2 may have refreshed. Click Create Unit
again. If desired, you can reduce the frequency with which
information refreshes in 3DM 2, or disable refresh temporarily, on
the 3DM Settings page.
Alarms Page
Figure 26. Alarms Page
The Alarms page appears when you click Alarms on the menu bar.
66
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
This page displays a list of AENs (asynchronous event notifications) received
from the controller displayed in the drop-down list in the menu bar.
Up to 1000 alarms can be listed. After the 1000-limit is reached, the oldest
alarms are deleted, as new ones occur.
You can sort the alarms by severity or time. To do so, just click the column
header.
For 8000 and 9000-series controllers, alarms can be used by either 3DM or
CLI, but not both. Whichever issues an alarms command first determines
which can see alarm data.
Clear Alarms. The Clear Alarms button removes all alarms shown in the list.
Sev. Shows the severity of the event. Three levels are provided:
■ Errors are shown next to a red box
■ Warnings are shown next to a yellow box
■ Information is shown next to a blue box
Time. The time shown for alarms generated by 7000- and 8000- series
controllers is the time retrieved from the driver by 3DM. The time shown for
alarms generated by 9000-series controllers is the time received by the driver
from firmware.
Message. The specific text relating to the alarm condition.
67
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
3DM Settings Page
Figure 27. 3DM Settings Page
The 3DM Settings page appears when you click 3DM Settings on the menu
bar. Use this page to set preferences, including email notification for alarms,
passwords, page refresh frequency, whether remote access is permitted, and
the incoming port for 3DM to listen for requests.
The initial settings for most of these preferences are specified during
installation of 3DM.
E-mail Notification
Use the fields in this section to set up and manage notifications of events by e-
mail.
Send E-mail. This field determines whether e-mail notification is Enabled or
Disabled.
68
3ware 9000 Series Serial ATA RAID Controller User Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3DM 2 Reference
Send Severity and Above. Specifies the type of events for which
notifications should be sent. A severity of Information will send e-mails for
all alarms, a severity of Warning will send e-mail for alarms with severity of
Warning and Error. A severity of Error will send e-mail for alarms with
severity of Error.
Sender. Enter the email address which will appear in the “From” field.
Recipient. The e-mail address to which notifications should be sent. You can
enter multiple addresses, separated by commas (,).
Server (name or IP). If the machine on which you are running 3DM has
access to a nameserver, you may enter the machine name of the mail server in
the Server field. Otherwise, use the IP address.
Save E-mail Settings button. Saves the e-mail notification settings.
Send Test Message button. Sends a test message using the saved e-mail
settings.
Password
Use the fields in this section to set the passwords for the User and
Administrator. When 3DM is first installed, the default password for both is
3ware.
Change Password For. Select the access level for which you are setting the
password: User or Administrator. Users can only view status information in
3DM, while Administrators can make changes and administer the controller
and associated drives.
Current Password. Enter the current password.
New Password. Enter the new password.
Confirm New Password. Enter the new password a second time, to be sure
you have entered it correctly.
Change Password button. Saves password changes.
Page Refresh
Minutes Between Refresh. Displays how frequently pages in 3DM will be
refreshed with new data from the controller. To change this setting, select
another option from the drop-down. If you prefer 3DM to only refresh when
you click Refresh Page, select Never.
The Login, Help and Drive SMART data pages do not automatically refresh.
All other 3DM pages do.
69
Download from Www.Somanuals.com. All Manuals Search And Download.
3ware Disk Manager (3DM 2)
Remote Access
Allow Remote Connections. This field enables or disables the ability for
users and administrators to access 3DM from a remote computer.
Incoming Port #
Listening Port. This field specifies the HTTP: port to be used by 3DM when
listening for communications. The default port setting is 888.
If you change this port, make sure the port you specify is not being used.
Failure to do so will cause 3DM to stop responding and you will have to
restart it by hand.
Change Port button. Saves a new port number.
70
3ware 9000 Series Serial ATA RAID Controller User Guide