035-04007-001_R3 V9070 OM Eng.fm Page 1 Tuesday, October 19, 2004 12:21 PM
HEPA AIR PURIFIER
Models V9070 and V9071
10. Do not expose the air purifier to rain, or use near
water, in a bathroom, laundry area or other damp
location.
11. The air purifier must be used in its upright position or
horizontal position only.
IMPORTANT
SAFETY
12. Do not allow foreign objects to enter ventilation or
exhaust opening as this may cause electric shock or
damage to the air purifier. Do not block air outlets or
intakes.
13. Locate air purifier near the outlet and avoid using an
extension cord.
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS
PRODUCT.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock, and injury to persons, including the
following:
14. This appliance has a polarized plug (one blade is
wider than the other). To reduce the risk of shock,
this plug is intended to fit only one way in a
polarized outlet. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit, contact
a qualified electrician. DO NOT attempt to defeat
this safety feature.
15. A loose fit between the AC outlet (receptacle) and
plug may cause overheating and a distortion of the
plug. Contact a qualified electrician to replace loose
or worn outlet.
1. Read all instructions before operating the air purifier.
2. Place air purifier where it is not easily knocked over
by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when not in
use.
16. Do not sit, stand or place heavy objects on the air
purifier.
17. Disconnect power supply before servicing.
4. To disconnect the air purifier, first turn controls to the
OFF position, grip the plug and pull it from the wall
outlet. Never pull by the cord.
5. Do not use any product with a damaged cord or plug
or if product malfunctions, is dropped or damaged in
any manner. Keep the cord away from heated
surfaces.
18. SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT USE THIS AIR
PURIFIER WITH ANY SOLID-STATE SPEED
CONTROL DEVICE.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully assembled.
8. Do not run power cord under carpets, and do not
cover with throw rugs. Arrange cord such that it will
not be tripped over.
9. Do not use air purifier where combustible gases or
vapors are present.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
035-04007-001_R3 V9070 OM Eng.fm Page 3 Tuesday, October 19, 2004 12:21 PM
Let the pre-filter air dry completely before
inserting back into the unit. If you need to replace
this item, please see Consumer Relations section
on the next page.
ELECTRONIC FILTER CHANGE REMINDER:
This model air purifier has an electronic filter
check to remind you when to check or replace the
Main filter based on the air purifier’s hours of use.
WHEN TO REPLACE THE MAIN FILTER?
Once a filter has reached the end of its expected
life, its light will remain on until it is RESET. You
These replacement intervals are intended as
guidelines only. Useful life expectancy of any filter
may unplug the air purifier without interrupting the media is dependent upon the concentration of
filter check memory function.
contaminates going through the system. High
concentrations of contaminates such as dust, pet
dander and pollen will reduce the useful life of
the filter.
A red LED light will illuminate when it is time to
change the filter. Please replace with Honeywell®
Main replacement filter number 16216.
NOTE: The Main Filter is not washable.
You should periodically check the filter.
Depending on operating conditions, the Filter
should be replaced every 6 months.
CLEANING AND STORAGE:
We recommend that you clean the air purifier at
least once a month and before extended storage.
Use only a dry cloth to wipe the external surfaces
of the air purifier. DO NOT USE WATER, WAX
POLISH, OR ANY CHEMICAL SOLUTION.
If your Air Purifier will not be used for more than
30 days, we recommend:
To RESET the Electronic Filter Check:
Fig 4
•
•
Remove the Main Filter from the unit.
Wrap the Main Filter in an air tight plastic bag.
Filter Monitor
Reset
When the filter monitor light remains on, it is time
to check/replace the Main filter and reset the filter
monitor, if needed. With the unit powered on,
insert the tip of a ball-point pen or paperclip next
to the LED filter check light and hold for
approximately 5 seconds until the light turns off
(Fig 4). Depending upon your individual usage
(environment and hours used), you may need to
check and replace the filter more or less
FREQUENTLY ASKED QUESTIONS:
My Air Purifier is starting to make noise and
the air output is less. What’s wrong?
The filters may be dirty. High amounts of
contaminates can block the pores in the filter
and stop the air from moving through it.
Replace the Filter.
How long should I run my Air Purifier?
For best results, you should operate your Air
Purifier 24 hours a day. This unit will be more
effective when doors and windows are closed.
Can I wash my Main filter?
frequently. If the Main filter is replaced before the
filter monitor light turns on, the filter monitor
should be reset at the same time.
MAINTAINING YOUR STAGE 1 WASHABLE
PARTICLE PRE-FILTER:
No. Washing the Main filter will destroy it.
The stage 1 particle pre-filter helps pick up large
airborne particles that enter the front grille. This
pre-filter can be periodically removed and shaken
to clean it. Alternatively, it can be rinsed by hand
under warm water.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
035-04007-001_R3 V9070 OM Eng.fm Page 4 Tuesday, October 19, 2004 12:21 PM
Some jurisdictions do not allow the exclusion
or limitation of incidental or consequential
damages or limitations on how long an implied
warranty lasts, so the above limitations or
exclusions may not apply to you. This warranty
gives you specific legal rights, and you also
may have other rights which vary from
jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this
product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in material
or workmanship. Defective product should be
returned to the place of purchase in
CONSUMER RELATIONS:
NOTE: IF YOU CONTINUE TO EXPERIENCE A
PROBLEM, PLEASE RETURN THE AIR
PURIFIER TO THE PLACE OF ORIGINAL
PURCHASE OR SEE YOUR WARRANTY. DO
NOT ATTEMPT TO OPEN THE AIR PURIFIER
YOURSELF. DOING SO MAY VOID YOUR
WARRANTY AND CAUSE DAMAGE TO THE
PRODUCT OR PERSONAL INJURY. IF YOU
HAVE ANY QUESTIONS REGARDING THE AIR
PURIFIER, PLEASE CALL OR WRITE:
accordance with store policy. Thereafter, while
within the warranty period defective product
may be returned to Kaz.
Kaz, Inc.
Consumer Relations Department
250 Turnpike Road
C. This warranty does not cover damage
resulting from any unauthorized attempts to
repair or from any use not in accordance with
the instruction manual.
Southborough, MA 01772
Toll Free: 1-800-827-6712
E-mail: [email protected]
D. Return defective product to Kaz, Inc. with a
brief description of the problem. Include proof
of purchase and a $10 check or money order
for handling, return packing and shipping
charges. Please include your name, address
and daytime phone number. You must prepay
shipping charges. Send to:
ACCESSORIES, REPLACEMENT FILTERS:
To order replacement Filter (16216), visit our
6712.
Washable Pre-Filter 16266: $5.25
Main Filter 16216: $29.99
In US:
Kaz, Inc.
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA
3 YEAR LIMITED WARRANTY
You should first read all instructions before
attempting to use this product.
A. This 3 year limited warranty applies to repair
or replacement of product found to be
defective in material or workmanship. This
warranty does not apply to damage resulting
from commercial, abusive, unreasonable use
or supplemental damage. Defects that are the
result of normal wear and tear will not be
considered manufacturing defects under this
warranty.
Patent Pending
Manufactured by KAZ, Inc. under license from The
Procter & Gamble Company, Cincinnati, Ohio USA
®
VICKS is a registered trademark of the Procter &
Gamble Company
KAZ IS NOT LIABLE FOR INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY
NATURE. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS
PRODUCT IS LIMITED IN DURATION TO
THE DURATION OF THIS WARRANTY.
© 2004 Kaz, Inc. All Rights Reserved.
P/N: 035-04007-001, Rev 3
Artwork: 043-01271-001
4
Download from Www.Somanuals.com. All Manuals Search And Download.
|