INSTALLATION AND OPERATION
TM
Direct-Vent
P/N 506056-01 REV. C 03/2010
Portland
MODEL
OTL Report No. 050-S-18b-5
US
SDVI
Ce manuel d’installation est disponible en francais, simplement en faire la
demande. Numéro de la pièce 506056-02.
WARNING AVERTISSEMENT
HOT GLASS WILL
CAUSE BURNS.
UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
DO NOT TOUCH GLASS
UNTIL COOLED.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
AVERTISSEMENT: Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire
au minimum le risque d’incindie ou d’explosion ou
pour éviter tout dommage matériel, toute blessure
ou la mort.
- Donotstoreorusegasolineorotherflammablevaporsand
liquids in the vicinity of this or any other appliance.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY AND WARNING
INFORMATION
AVERTISSEMENT
On ne devrait pas placer de vêtements ni d’autres
matières inflammables sur l’appareil ni à prox-
imité.
WARNING
Youngchildrenshouldbecarefullysupervisedwhen
they are in the same room as the appliance. Tod-
dlers,youngchildrenandothersmaybesusceptible
to accidental contact burns. A physical barrier is
recommended if there are at risk individuals in the
house. To restrict access to a fireplace or stove,
install an adjustable safety gate to keep toddlers,
young children and other at risk individuals out of
the room and away from hot surfaces.
WARNING
Any safety screen or guard removed for servicing
the appliance must be replaced prior to operating
the appliance.
AVERTISSEMENT
Tout écran ou protecteur retiré pour permettre
l’entretien de l’appareil doit être remis en place
avant de mettre l’appareil en marche.
AVERTISSEMENT
Lesjeunesenfantsdevraientêtresurveillésétroite-
mentlorsqu’ilssetrouventdanslamêmepièceque
l’appareil. Les tout petits, les jeunes enfants ou les
adultespeuventsubirdesbrûluress’ilsviennenten
contact avec la surface chaude. Il est recommandé
d’installerunebarrièrephysiquesidespersonnesà
risqueshabitentlamaison. Pourempêcherl’accès
à un foyer ou à un poêle, installez une barrière de
sécurité; cette mesure empêchera les tout petits,
les jeunes enfants et toute autre personne à risque
d’avoir accès à la pièce et aux surfaces chaudes.
WARNING
Improper installation or use of this appliance can
cause serious injury or death from fire, burns,
explosion or carbon monoxide poisoning.
WARNING
Children and adults should be alerted to the hazards
of high surface temperature and should stay away to
avoid burns or clothing ignition.
WARNING
Improper installation, adjustment, alteration, ser-
vice or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency or the gas supplier.
AVERTISSEMENT
Les enfants et les adultes devraient être infor-més
des dangers que posent les températures de surface
élevéesetseteniràdistanceafind’éviterdesbrûlures
ou que leurs vêtements ne s’enflamment.
WARNING
Failure to comply with these installation instructions
will result in an improperly installed and operating
appliance, voiding its warranty. Any change to this
appliance and/or its operating controls is danger-
ous.
WARNING
DO NOT ATTEMPT TO ALTER OR MODIFY THE CON-
STRUCTION OF THE APPLIANCE OR ITS COMPO-
NENTS. ANY MODIFICATION OR ALTERATION MAY
VOIDTHEWARRANTY,CERTIFICATIONANDLISTINGS
OF THIS UNIT.
WARNING
Clothing or other flammable material should not
be placed on or near the appliance.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
These appliances are vented gas appliances. Do not burn wood
FORYOURSAFETYdonotinstalloroperatethisappliancewithout
first reading and understanding this manual. Any installation or
operation of the appliance deviating from that which is stated
in this manual WILL void the warranty and may be hazardous.
or other material in these appliances.
This appliance is only for use with the type of gas indicated on
rating plate. This appliance is not convertible for use with other
gases, unless a certified kit is used.
INSTALLATIONANDREPAIRSHOULDONLYBEDONEBY
A QUALIFIED SERVICE TECHNICIAN. DO NOT ATTEMPT
TO SERVICE THE APPLIANCE YOURSELF.
Cet appareil doit être utilisé uniquement avec les types de gaz
indiqués sur la plaque signalétique. Ne pas l'utiliser avec
d'autres gaz sauf si un kit de conversion certifié est installé.
Do not make any make-shift compromises during installation.
Any modification or alteration may result in damage to the
appliance or dwelling and will void the warranty, certification
and listings of this unit.
Hot while in operation. Do not touch. Severe Burns may result.
Keep children, clothing furniture, gasoline and other liquids
having flammable vapors away.
Failure to use manufacturer provided parts, variations in tech-
niques and construction materials or practices other than those
described in this manual may create a fire hazard and void the
limited warranty.
L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher
l’appareil. Risque de brûlures graves. Surveiller les enfants.
Garderlesvêtements,lesmeubles,l’essenceouautresliquides
produisant des vapeur inflammables loin de l’appareil.
This gas appliance must be equipped for the proper fuel type
and altitude at which it will be operated. Any operation outside
the parameters outlined in this manual may result in a hazard-
ous condition and will void the warranty. Please carefully read
the sections pertaining to these subjects and/or be sure your
appliance is properly equipped.
This appliance may be installed in an aftermarket, permanently
located, manufactured home (USA only) or mobile home, where
not prohibited by local codes.
Cet appareil peut être installé dans une maison préfabriquée
(mobile) déjà installée à demeure si les règlements locaux le
permettent.
Never use solid fuels such as wood, paper, cardboard, coal, or
any flammable liquids, etc., in this appliance.
Ensure clearances are in accordance with local installation
codes and the requirements of the gas supplier.
Any grill, panel, or glass removed for service MUST be replaced
prior to operating the appliance. Do not operate appliance with
the glass front removed, cracked or broken.
Dégagement conforme aux codes d'installation locaux et aux
exigences du foumisseunde gaz.
Gold and nickel plated surfaces must be cleaned with glass
cleaner and a clean soft cloth before firing the first time or
fingerprints will remain permanently. NEVER use brass polish
to clean gold or nickel, this will remove the plating!!!
Installation and repair should be done by a qualified service
person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent
cleaning may be required due to excessive lint from carpet-
ing, bedding material, etcetera. It is imperative that control
compartments, burners and circulating air passageways of the
appliance be kept clean.
When opening the lower door on the face while the appliance is
burning, pull at the far left or far right vent openings, because
the door is hot during operation.
L’installationetlaréparationdevraitêtreconfiéesàuntechnicien
qualifié. L’appareil devrait faire l’objet d’une inspection par un
technicien professionnel avant d’être utilisé et au moins une
fois l’an par la suite. Des nettoyages plus fréquents peuvent
être nécessaires si les tapis, la literie, et cetera produisent une
quantité importante de pous-sière. Il est essentiel que les com-
partiments abritant les commandes, les brûleurs et les conduits
de circulation d’air de l’appareil soient tenus propres.
LHP, its employees, or any of its representatives assume no
responsibility for any damages caused by an inoperable, inad-
equate,orunsafeconditionasaresultofanyimproperoperation,
service or installation procedures, whether direct or indirect.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
En raison des températures élevées, l’appareil devrait être
installé dans un endroit où il y a peu de circulation et loin du
mobilier et des tentures.
Do not use these appliances if any part has been under water.
Immediately call a qualified, professional service technician
to inspect the appliance and to replace any parts of the control
system and any gas control which have been under water.
Provide adequate clearances around air openings and adequate
accessibility clearance for service and proper operation. Never
obstruct the front openings of the appliance.
Ne pas utiliser cet appareil s’il a été plongé, même partielle-
ment, dans l’eau. Appeler un technicien qualifié pour inspecter
l’appareil et remplacer toute partie du système de commande
et toute commande qui a été plongée dans l’eau.
These appliances are designed to operate on natural or propane
gas only. The use of other fuels or combination of fuels will
degrade the performance of this system and may be danger-
ous.
Only trim kit(s) supplied by the manufacturer shall be used in
the installation of this appliance.
Theseappliancesaredesignedassupplementalheaters.There-
fore, it is advisable to have an alternate primary heat source
when installed in a dwelling.
Seuleslestroussesdegarniturefourniesparlefabricantdoivent
être utilisées pour l’installation de cet appareil.
INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE
These appliances must not be connected to a chimney or flue
HOME OWNER!
serving a separate solid fuel burning appliance.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Fireplace Requirements
ORIFICE SIZE/ALTITUDE ADJUSTMENT
These heaters are designed to be installed into an existing masonry
fireplace (built to UBC 37 or ULC S628 standards) or factory built solid
fuel, wood burning fireplace (listed to UL 127 or ULC S610) only. All
exhaust gases must be vented outside the structure. Combustion air
is drawn from outside the structure. When installing in a factory built
fireplace, the fireplace grate must be removed and the damper must be
removed or secured open.
For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice
should be de-rated by 4% for every 1,000 feet to maintain the proper ratio
of gas to air. Improper orifice sizing may result in damage and unsafe
conditions. Changingtheorificeshouldonlybedonebyaqualifiedservice
technician. Contact your LHP dealer for proper orifice sizes.
Ifthefactory-builtfireplacehasnogasaccesshole(s)provided, anaccess
hole of 1-1/2 inches (38 mm) or less may be drilled through the lower
sides or bottom of the firebox in a proper workmanship like manner. This
access hole must be plugged with a non-combustible insulation after the
gas supply line has been installed. The installer must mechanically attach
themarkingsuppliedwiththegasfireplaceinserttotheinsideofthefirebox
of the fireplace into which the gas fireplace insert is installed.
SMOKE DETECTORS
Since there are always several potential sources of fire in any home, we
recommend installing smoke detectors. If possible, install the smoke
detector in a hallway adjacent to the room (to reduce the possibility of
occasional false activation from the heat produced by the appliance). If
your local code requires a smoke detector be installed within the same
room, you must follow the requirements of your local code. Check with
your local building department for requirements in your area.
IMPORTANT: When installing these appliances into a factory
built fireplace or heat-form, the air flow within and around the
fireplace shall not be altered by the installation of the insert
(i.e. DO NOT BLOCK louvers or cooling air inlet or outlet ports,
circulating air chambers in a steel fireplace liner or metal heat
circulator).
THE SDVI FIREPLACE INSERT
• Must conform with all local, state, and national installation codes. In
theabsenceoflocalcodes, theinstallationmustconformwithNational
Fuel Gas Code ANSI Z223.1 - latest edition, also known as NFPA 54
(In Canada, the current CAN/CSA B149.1 installation code). Refer to
the National Fuel Gas Code and local zoning and code authorities for
details on installation requirements.
• Mobile home installations must conform with the Mobile Home Con-
struction and Safety Standard, Title 24 CFR, Part 3280 (in Canada
CAN/CSA Z240 MH), or, when such a standard is not applicable, the
Standard for Mobile Home Installations, ANSI A225.1 - latest edi-
tion.
WARNING
THIS FIREPLACE HAS BEEN ALTERED TO
ACCOMMODATE A FIREPLACE INSERT AND
SHOULD BE INSPECTED BY A QUALIFIED
PERSON PRIOR TO RE-USE AS A
CONVENTIONAL FIREPLACE.
• Must be vented directly to the outside in accordance with the latest
edition of the National Fuel Gas Code and must never be attached to
a chimney serving a separate solid fuel burning appliance.
• Has been certified for use with either natural gas or propane.
• Is not for use with solid fuels.
• Is approved for sitting rooms and/or bedrooms.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
CODES AND APPROVALS
Certification
COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS
(Massachusetts Approval #G3-0806-6)
These appliances are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
Gas appliances must be tested and certified by a nationally recognized
testing and certification laboratory to ANSI (American National Standard
Institute) gas appliance safety standards.
• Install this appliance in accordance with Massachusetts Rules and
Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e).
This insert has been tested and certified by OMNI -Test Laboratories to
ANSIZ21.88/CSA2.33StandardforVentedGasFireplaceHeaterandCGA
2.17-M91andUL307BGasBurningHeatingAppliancesforManufactured
(Mobile) Homes in both USA and Canada.
• Installation and repair must be done by a plumber or gas fitter licensed
in the Commonwealth of Massachusetts.
• The flexible gas line connector used shall not exceed 36 inches (92
centimeters) in length.
It has met all necessary ANSI Standards and is fully certified for installa-
tion in any community. If there are any questions or if you need further
substantiation either write to or call your LHP dealer. If you have further
questions, please contact LHP.
• The individual manual shut-off must be a T-handle type valve.
Massachusetts Horizontal Vent Requirements
Checkalllocalbuildingandsafetycodesbeforeinstallation.Theinstallation
instructions and appropriate code requirements must be followed exactly
and without compromise. In the absence of local codes the following
standards and codes must be followed.
IntheCommonwealthofMassachusetts,horizontalterminationsinstalled
less than seven (7) feet above the finished grade must comply with the
following additional requirements:
• A hard wired carbon monoxide detector with an alarm and battery
back-up must be installed on the floor level where the gas fireplace
is installed. The carbon monoxide detector must comply with NFPA
720, be ANSI/UL 2034 listed and be ISA certified.
The Installation must conform to local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest
edition (In Canada, the current CAN/CSA-B149.1 installation code).
The appliance, when installed, must be electrically grounded and wired
in accordance with local codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian
Electrical Code, CSA C22.1 - latest edition.
• A metal or plastic identification plate must be permanently mounted to
the exterior of the building at a minimum height of eight (8) feet above
grade and be directly in line with the horizontal termination. The sign
must read, in print size no less than one-half (1/2) inch in size, GAS
VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.
NEW YORK CITY, NEW YORK (MEA)
Installation of these appliances are approved for installation in New York
City in the US state of New York (MEA#: 138-07-E).
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Packaging List
PRE-INSTALLATION
To install a SDVI insert, an insert body, face, surround (flange) kit are
required.
Features
Installation Options
Insert Body Packaging List
Residential - Vented Vertical Only
Manufactured (Mobile) Home
Natural Gas Or Propane (LP)
Bedrooms
1 Insert Body with Burner Cassette
1 Log Set
1 Bag of Embers
Optional Wall-mounted Or Remote Thermostat
1 Fasteners:
6 slotted 1/4" truss screws
6 speed nuts
Electrical
9 spring clips
3 plastic adhesive wire restraints
1 Installation and Operation Manual
The blower motor requires 120 Volts AC for operation. The fireplace is not
dependent on the blower or an outside electrical supply to operate.
Millivolt Valve
Decorative Face Kits - One Required
This insert is operated with a millivolt valve and therefore burns even
during a power outage.
• Arched Black Nickel Face, Surround (27" x 39"),
and Black Trim
• Arched Brushed Nickel Face, Surround (27" x 39"),
and Black Trim
• Arched Black Face, Surround (27" x 39"),
and Black Trim
Fuel
Thisinsertcomesfromthefactoryequippedtoburnnaturalgasataspeci-
fied elevation. The insert can be converted to burn LP (liquid propane) by
installingaconversionkit.OnlyLHPconversionkitscanbeusedtoconvert
from NG to LP or LP to NG. Contact your LHP dealer for details.
Surround Components Include:
1 Top Surround
2 Side Surrounds
3 Black Extruded Trim Pieces
2 Elbowed Trim Fasteners
SDVI
NATURAL GAS
25,000/17,500
LP GAS
RATINGS
Max/Min Input BTUh 0-2,000 Feet
25,000/18,500
(0-610 M)u
Manifold Pressure (IN. WC)
Min. Inlet Pressure (IN. WC)
3.5
10.0
5.0
10.5
63.95%
67.20%
P4 Efficiency
v
Orifice (DMS) 0-2,000 Feet (0-610 M)u
#41 (.096")
#53 (.0595")
uUnit factory equipped for 0-2000 FT/0-610 M, In Canada 0-4500 FT/0-1370 M
vTested to CSA P.4.1-02 “Testing Method for Measuring Annual Fireplace Efficiency.
Electrical Rating: 120 VAC, 60 HZ, Less Than 2 Amps
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Insert Dimensions
Minimum Fireplace Cavity
31-1/4”(794mm)
16”(406mm)
Air Intake
Flue
2-1/2”
(64mm)
7-1/4”
(184mm)
A
B
14-1/2”
(368mm)
15-3/4”
(400mm)
C
D
13”
(330mm)
Top View
Figure 1
Figure 3
CAUTIONS
15-1/4”
(387mm)
• Trim panels or surrounds must not seal ventila-
tion openings in the existing fireplace that the
appliance is installed in.
• The fireplace in which this gas insert is to be
installed must be thoroughly cleaned if it has
been used to burn wood or synthetic logs. Have
the chimney and all inside surfaces of the fire-
place brushed and vacuumed so that no soot,
embers, or loose combustion deposits can be
drawnintotheheatcirculationblowerandblown
into the living area.
17-1/4”
(438mm)
7-1/2”
(191mm)
• Ifanyportionofthechimneysystemshowssigns
of structural or mechanical weaknesses, such
as: cracks, leaky joints, corroded or warped
surfaces, the faulty portion must be repaired
or replaced prior to installing this appliance.
• The factory built firebox must accept the insert
withoutmodificationotherthanremovingbolted
or screwed together pieces such as baffles /
smoke shelf / deflectors, ash lips, glass door,
screen or door tracks, log grates, refractory or
masonry lining and damper assemblies. Any
fireplacecomponent,whichisremoved,mustbe
retainedsotheycanbereinstalledtorestorethe
fireplace to its original operating condition. The
removal of any part must not alter the integrity
oftheoutershellofthepre-engineeredfireplace
cabinet in any way. Any parts removed must be
replaceable. If any components are removed
from (or altered) from the existing fireplace,
a Warning Label (see Page 5) must be affixed
inside the fireplace firebox, so that it shall be
visibleuponremovalofthefireplaceinsert. Note:
RTV high temperature silicone is an approved
adhesive to affix the label.
Figure 2
Side View
Insert Dimensions
Width of insert behind Surround Panels
Rear height
31-1/4" (794mm)
17-1/4" (438mm)
15-3/4" (400mm)
Insert depth into fireplace
Flue center line from back of surround with 45º collar 13-3/4" (349mm)
Flue collar diameter (OD)
2-15/16" (75mm)
Minimum Fireplace Opening Required
A = 31-1/4” (794mm) Front Opening
B = 17-1/4” (438mm) Height
C = 19” (483mm) Rear Width**
D = 16” (406mm) Fireplace Depth
* Top air duct will need to be removed for short ZC applications. Replace
tap tights when removed.
**This dimension is with the air duct hood removed (see Zero Clearance
Fireplace Installation on Page 11).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MINIMUM CLEARANCES TO COMBUSTIBLES
Facing and Mantel Clearances
Minimum clearances include any projections such as shelves, window
sills,mantels,spacers/standoffsorsurfacestocombustibleconstruction
etc. above the appliance. Paint or lacquer used to finish the mantel
must be heat resistant in order to avoid discoloration.
3"/76mm
3"/76mm
The letters below, E through J, correspond to Figure 5 showing minimum
clearancesrequiredfromtheappliancetocombustiblesandtheminimum
projection of the hearth extension.
3"/76mm
Facing and
Mantel
1-1/2”
38mm
Side View
E
F
= 31-1/2" (800mm) from Top Facing to Bottom of Insert
= 25-1/2” (648mm) from Center of Glass to Side Facing or Side
Wall
39-1/2”
1003mm
33-1/2”
851mm
J
= 39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert
36-1/2”
927mm
31-1/2”
800mm
HEARTH PROTECTION
G = Minimum Hearth Protection from Front of Insert*
H = Vertical Distance from Insert Bottom to Combustible Material.
G
H
13”(330mm)
0”(0mm)
10”(254mm)
2”(21mm)
0”(0mm)
Figure 4
4”(102mm)
Clearances
Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible
or equivalent, with a k factor of .84.
Mantel
MANTEL
INSERT LEVELING
Trim
TRIM
F
At each front and rear corner of the insert is an adjustable leg provided
to level the insert should the hearth of the fireplace be uneven. To adjust
the legs, loosen the two 5/32" allen head screws, move the leg to the
desired height, and then tighten the screws. Repeat these steps for each
adjusting leg.
J
E
C
L
H
G
Hearth / Floor Protection
Figure 5
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: The minimum vertical rise (exhaust vent) is 10 feet (3.1 M) and the
maximumverticalriseis35feet(10.7M).Thesedimensionsaremeasured
from the starting collars of the unit to the end of the vent pipe.
INSTALLATION
Venting Installation
The fireplace and fireplace chimney must be clean and in good working
order and constructed of non-combustible materials. Inspect chimney
cleanouts for proper fit and seal.
Your Superior™ gas insert must be vented to the outside in accordance
with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In
Canada, the current CAN/CSA B149.1 installation code). The insert
must not be connected to a chimney flue serving a separate solid fuel
burning appliance.
* Other approved vent components include; Standard Simpson Dura-
vent Co-linear Chimney Liner Kit, Direct-Vent Termination #991, Liner
Termination Kit (includes termination connector and flashing) #923GK
and 3" x 35' Alum Flex #2280
This gas insert requires a 3” diameter listed flex liner. The vent should
terminatewithalisteddirect-ventterminationcap.Thechimneyshouldbe
sealed around the cap to prevent air and rain from entering the chimney.
Adhere to the vent manufacturer's instructions for installation and vent
termination. These appliances are approved for use with the following
vent kits.
The standard cap in Termination Kit TKDVI, and in
Vent Kit DV3FK35 is a high wind cap
Theexistingfireplacechimneys
may take various contours
which the flexible liners will
Vent Kits
Cat. No.
Model
Description
accommodate. However, keep
the flexible liner as STRAIGHT
aspossible,avoidunnecessary
bending.
Vertical Cap
H0909
FKDVI
Flex Liner Kit, DVI 3” X 35’ (requires 2, one for
exhaust and one for intake)
Termination
Connector
TKDVI
TKDVI
Termination Kit, DVI (termination cap and flashing)
DV3FK35 DV3FK35 Flex Liner and Termination Kit, 3" X 35' (includes 2
flex liners, termination and gear clamps)
Liner Requirements:
Use 3" (76 mm) diameter listed gas
vent liner (UL1777 ONLY) for the
EXHAUST
Vertical Venting
The vent pipes must be connected to the proper collars on the unit and
the exhaust vent pipe must be connected to the termination cap or the
unit will not operate.
Use 3" (76 mm) diameter listed
liner (UL 181 or UL1777) for the
AIR INTAKE.
Exhaust
Intake
The combustion air intake pipe can be connected to the termination cap
(see Figure 6b) or it can terminate inside the chimney (see Figure 6a).
If combustion air intake pipe is terminated inside the chimney and not
connected to the actual termination cap the bottom opening of the chim-
ney (chimney throat) must be sealed around the vent pipes. Use a non
combustible seal-off plate (i.e. 22 gage sheet steel) or unfaced fiberglass
insulation (8 lb per square foot density minimum) to seal around the vent
pipes. Whichever “seal off” method is used must effectively seal the area
topreventroomairpassagetothechimneyofthefireplace. Theinsulation
may give off an odor during the first hour of operation.
Vertical Height Min. = 10 ft. (3.1 M)
Vertical height Max. = 35 ft. (10.7 M)
Note: Measured from flue collar on
unit to the end of the vent pipe or liner
The flexible vent pipe
must NOT be allowed to
sag behind insert or in
fireplace flue.
NOTE: Terminating the air intake liner as shown here may not be al-
lowed by some local codes. Check with the authority having jurisdiction
for your area.
The outside air inlet does not
require a full reline (if intake
liner is terminated in chimney
and a positive flue connection
is achieved as specified).
Exhaust 3" (75mm) UL
1777. A full length liner
is required from the
exhaust outlet on appli-
ance to center collar of
termination cap.
Figure 6b
Combustion Air Intake
Existing Fireplace Flue
(chimney)
Makesurethatbothlinerswillpassthroughexistingdamperarea.Remove
or lock damper to allow the passage of the flexible liners. If the damper
will not allow the passage of both liners, DO NOT PROCEED FURTHER.
(If fireplace is masonry) Consult a local mason for removal of the damper
without risk of structural damage or leakage (if the fireplace is factory
built) The appliance may NOT be installed into the fireplace.
WARNING
Positive Flue Con-
nection (sealing
fireplace throat
Direct-VentFireplaceInsertVentRequirements-Useliner
listed to UL181 (Factory-made Air Ducts And Air Connec-
tors)orUL1777(ChimneyLiners)fortheAIRINTAKE. Use
liner listed to UL1777 ONLY for the EXHAUST.
using a noncombus-
tible seal-off plate
Air Inlet Liner (for combustion air) When
terminating the air inlet liner at this point, a
positive flue connection is required (to ensure
combustion air is drawn down the chimney
only).
or insulation).
Donotsubstitutetheheat-ratedflexliner(UL1777)forthe
exhaustwithanyothertypelinerorafiremayresultcaus-
ing property damage, personal injury or loss of life.
Masonry and Factory Built Fireplaces
Figure 6a - Terminating Air Inlet in Chimney
10
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Zero Clearance Fireplace Installation
This insert may be installed in a masonry or factory built/zero clearance
(ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be
removed and the ZC damper must be removed or secured open. The ZC
doors, screen, refractory or masonry lining, baffles, and smoke shelf may
be removed if necessary to install the gas insert. However, do not cut
or alter the fireplace components. The removal of any parts to facilitate
installation must not alter the integrity of the inner or outer shells of the
fireplace cabinet. Any parts removed must be replaceable if the insert is
taken out of the fireplace or the fireplace must be clearly marked with the
metal label that states: "This fireplace has been altered and is no longer
safe to operate." The insert is designed to fit into a ZC fireplace with a
minimum firebox height of 17-1/4" (438mm). To facilitate this the hood
will need to be removed and discarded (Note: The screws should be
replaced in the insert body). Installation of the flue collar is removable
(see Flue Collar Connection).
2 Screws
If the factory-built fireplace has no gas access hole(s) provided, an ac-
cess hole of 1-1/2" (37.5 mm) or less may be drilled through the lower
sides or bottom of the firebox in a proper workmanship like manner. This
access hole must be plugged with a non-combustible insulation after the
gas supply line has been installed.
Figure 7
Si le foyer préfabriqué ne comporte pas d’orifices d’amenée du gaz, un
orifice d’au plus 37,5 mm (1,5 po) peut être pratiqué, selon les règles
de l’art, dans la partie inférieure des parois ou au fond de la chambre de
combustion. Cetorificedoitêtreobturéaumoyend’isolantincombustible
une fois la conduite de gaz en place.
Rear Log
The installer must mechanically attach the marking supplied with the gas
fireplace insert to the inside of the firebox of the fireplace into which the
gas fireplace insert is installed.
Retainer
Log Set Installation
If logs are not installed according to the log installation instruc-
tions, flame impingement and improper combustion could
occur and result in soot and/or excessive production of carbon
monoxide (CO), a colorless, odorless, toxic gas.
Figure 8
The size and position of the log set is critical to achieve a safe,
reliableandattractiveflamepattern. Anyattempttouseadiffer-
ent log set in the fireplace will void the warranty and will result
in incomplete combustion, sooting, and poor flame quality.
*Brick Panels are not offered for the SDVI Gas Insert.
1. Removelograck(2screws)andinstallrearlogonretainer.SeeFigures
7 and 8).
2. Reinstall log rack with rear log. IMPORTANT!!! SCREWS PASS
THROUGH LOG RACK AND BURNER PAN.
3. Install light layer of mineral wool directly over ports. See Figure 9.
- A light layer will give a more constant rear flame.
- A heavy layer will give more glow, but will need to be adjusted after
light up.
Figure 9
4. Install front logs on retainer slots. See Figure 10.
5. Place top log on pin. See Figure 11.
6. Place black embers around perimeter of mineral wool. Important!!!
Do not cover ports with black embers. See Figure 11.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Fasten top surround panel with the remaining two truss screws.
Tighten all six truss screws after adjusting the surround panels to
eliminate space between side and top surround panels.
5. Assemble the surround trim by inserting the elbowed retainer in the
rectangular slot in the ends of the longest piece of trim and secure by
tightening the screw in the retainer. Slide the mitred ends of the two
side trim pieces onto the elbowed retainer and secure by tightening
the retainer screw.
Install front logs
on retainer slots
6. The fastened trim pieces should now be horseshoe shaped. Slide
the trim down over the surround panels so the edge of the surround
panel fits just behind the rounded edge of the trim.
7. Install three spring clips (found in parts bag in firebox) in each piece
of trim by inserting them between the rear of the surround panel
and the channel of the trim. The spring clips will push the trim tight
to the surround panel.
Front Logs
Figure 10
A
Spring Handle Latches
B
C
Door Mounting Plates
Top Log
Figure 12
Ports
Place Top Log On Pin
Face Installation
The faces come with hooked brackets. To install the face, hang the hooked
brackets on the surround brackets per instructions provided in decorative
face kit (C in Figure 12).
Figure 11
Surround Panels Installation
The SDVI insert surround panels are made of heavy gage steel for durabil-
ity and, if desired, for the ease of making an inside fit in the fireplace.
1. Remove the speed nuts (A in Figure 12) from the parts bag and
install (with the flat surface forward) on the six holes in the surround
brackets - three on each side of the insert (B in Figure 12). A flat
bladed screwdriver may help in installing the nuts.
2. Install all surround panels and trim with the insert positioned in the
fireplace but a few inches in front of its final location.
3. Install the side surround panels by lining up the holes in the tabs
on the side surround panels in front of the holes on the surround
brackets. Next insert two slotted 1/4" truss screws for each side
surround panel and secure loosely.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Gas Line Installation
Fuel
Type
Inlet Pressure
Manifold Pressure
Desired Minimum Maximum
On Hi
Fire
On Lo
Fire
After leveling, position the insert in the fireplace - holding it about six
inches out from its final location.
Natural 7" WC
Gas
5" WC
10.5" WC 3.5" WC 1.7" WC
CAUTION: Specific hearth requirements apply (see Clearances
to Combustibles).
LP Gas 11" WC 10.5" WC 13" WC
10" WC 5.4” WC
The SDVI gas insert must be connected to the gas line in accordance with
local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada,
the current CAN/CSA B149.1 installation code). The insert comes with
an 8" nipple attached to the supply side of the gas valve. After connect-
ing the gas line, all joints in the line and connections at the valve should
be checked for leaks before final positioning of the unit. Conduct a gas
leakage test of the appliance piping and control system downstream of
the shutoff valve in the supply line to the appliance.
Robertshaw Millivolt Gas Valve
TH
TP
TP/TH
Inlet (Supply)
Pressure Tap
The Manifold
(Outlet) Tap
Gas Pressure Requirements
A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS
APPLIANCES IS IMPROPER GAS PRESSURE!
Figure 13
The most important item to check during the initial installation
and the first thing to check when operating problems occur is
gas pressure! This appliance will not function properly unless
the required gas pressure is supplied. See the table on this
page for gas pressure requirements.
LP and Natural Gas Supplies
Your SDVI gas insert is equipped from the factory for use with natural
gas only as specified on the Safety / Listing label attached to the appli-
ance. This appliance can only be operated using propane gas (LP) if a
certified fuel conversion kit provided by LHP is installed by a qualified
service technician.
Twopressuretapsareprovidedontheinsert'svalvetocheckgaspressures.
The taps are located to the right of the on/off/pilot knob (see Figure 15).
The bottom tap is the inlet (supply) pressure side. To check inlet pressure
(with the insert burning), insert a small phillips screwdriver into the tap
and turn a half turn counter-clockwise. Cover the tap with the line from
a manometer and check the pressure. Close tap gently but securely after
completing the check. The manifold (outlet) tap is above the inlet tap.
To check manifold pressure (with the insert burning at the high burn
setting) insert a small phillips screwdriver into the tap and turn a half
turn counter-clockwise. Cover the tap with the line from the manometer
and check the pressure. Again, close the tap gently but securely after
completing the check. Check the taps for gas leaks with a gas leak test
solution (retighten if necessary).
Also check the orifice size on the label on the igniter bracket. It must be
the correct size for the fuel and altitude.
Do not run propane tank dry. Running the tank dry may cause a
hazardous condition due to pressure drop in empty tank.
Solid fuel is NOT to be used with this unit.
Air Shutter Adjustment
If the pressure is not sufficient, make sure the gas supply line is large
enough, the supply regulator is properly adjusted, and the total gas load
for the residence does not exceed the amount supplied.
The SDVI gas insert has an air shutter control lever located behind the
lower door on the insert's face and to the left of the gas valve (see Figures
14 and 15). The lever is linked to the primary air shutter on the main
burner. The air shutter regulates the amount of primary air the burner
receives and therefore how clean the insert burns. The air shutter should
only be adjusted by a qualified gas technician. The insert should burn
for about 15 minutes with the logs installed before adjusting the air
shutter. More air will result in shorter flames and less color, less air will
result in bigger flames and more color. To adjust the air shutter, insert
a regular screwdriver into the slide adjustment and slide it side to side
(see Figures 14 and 15).
Propane tanks are at pressures that will cause damage to valve com-
ponents. Verify that the tanks have step down regulators to reduce the
pressure to safe levels.
These appliances must be isolated from the gas supply piping system
(by closing their individual manual shut-off valve) during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
CAUTION: The air shutter should never be set so as to make the
tips of the flames sooty or create sooting on the viewing glass,
logs, or heat exchanger. If soot begins to form after burning,
the air shutter should be opened gradually until the sooting
condition stops. Gas quality and gas pressure may vary, which
can affect the burning characteristics of the insert.
These appliances and their individual shut-off valves must be discon-
nected from the gas supply piping system during any pressure testing
of that system at pressures greater than 1/2 psig (3.5 kPa).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Moving shutter
bracket to the right
will open shutter,
to the left will close
shutter.
Shutter Adjustment Detail
See Detail Shutter Adjustment
Figure 15
Figure 14
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS
It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a
critical step in informing consumers of safe operation of this appliance.
ATTACHING SAFETY IN OPERATION WARN-
INGS
APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóNDEADVERTENCIASDESEGURIDAD
À LA SÉCURITÉ D’UTILISATION EN OPERACIóN
It is required that the safety instruction labels fur-
nished with the fireplace be affixed to the operation
andcontrolpointofthefireplace. Asafetyinstruction
label must be affixed to the wall switch plate where
the fireplace is turned on and off (See Figure A)
or wall thermostat (See Figure B) and if used on
the remote control handheld transmitter (Figure
C). To properly complete the installation of this
fireplace, locate the multi-lingual adhesive labels
provided with the Care and Operation Instructions
and proceed as follows:
Il est impératif que les étiquettes de sécurité fournies Se requiere que las etiquetas de instrucciones de
avec le foyer soient collées à côté des dispositifs seguridad incluidas con la chimenea se coloquen en
de contrôle du foyer. Une étiquette de sécurité doit el punto de operación y control de la misma. Se debe
être collée sur la plaque de l’interrupteur contrôlant colocar una etiqueta de instrucciones de seguridad
l’allumagedufoyer(voirFigureA)ousurlethermostat en la placa del interruptor de pared desde el cual se
mural (voir Figure B) et, le cas échéant, sur le boîtier enciendeyseapagalachimenea(verlaFiguraA)oenel
delatélécommande(FigureC). Pouracheverl’instal- termostatodepared(verlaFiguraB)yeneltransmisor
lationcorrectedecefoyer, procédezcommesuitavec decontrolremoto(FiguraC)siseusa. Paracompletar
lesétiquettesadhésivesenlanguesétrangèresfournies correctamente la instalación de esta chimenea,
avec les instructions d’utilisation et d’entretien :
encuentrelasetiquetasadhesivasmultilingüesincluidas
con las instrucciones de cuidado y operación y haga
lo siguiente:
1. Repérez l’interrupteur ou le thermostat mural qui
contrôle le foyer (vérifiez que l’interrupteur
1. Locate the wall switch or wall thermostat that
controlsthefireplace(verifytheswitchoperates
the fireplace by turning it on and off). Clean the
wall switch plate or wall thermostat thoroughly
to remove any dust and oils. Affix the label to
the surface of the plate of the wall switch that
controls the fireplace (Figure A) or the wall
thermostat (Figure B). Choose the language
primarily spoken in the home. If unknown, affix
the English language label.
2. Ifaremotecontrolisusedtocontrolthefireplace,
locate the transmitter and clean it thoroughly
to remove any dust and oils. Affix the label to
the surface of handheld transmitter (Figure C).
Choose the language primarily spoken in the
home. If unknown, affix the English language
label.
contrôle le fonctionnement du foyer en le faisant 1. Identifique el interruptor o el termostato de pared
basculerdeMarcheàArrêt,etvice-versa).Nettoyez
soigneusement la plaque murale de l’interrupteur
ou le thermostat mural pour éliminer la poussière
et les traces de graisse ou d’huile. Collez l’étiquette
sur la surface de la plaque de l’interrupteur mural
qui contrôle le foyer (Figure A) ou du thermostat
mural (Figure B). Choisissez la langue qui est
principalement parlée dans la résidence du
propriétaire. En cas de doute, collez l’étiquette en
anglais.
quecontrolalachimenea(verifiquequeelinterruptor
opera la chimenea encendiéndola y apagándola).
Limpie bien la placa del interruptor o el termostato
de pared para quitar el polvo y aceite. Pegue la
etiquetaenlasuperficiedelaplacadelinterruptorque
controla la chimenea (Figura A) o en el termostato
de pared (Figura B). Seleccione el idioma que
más se habla en la casa. Si no sabe cuál es, use la
etiqueta en inglés.
2. Si se usa un control remoto para controlar la
chimenea, encuentre el transmisor y límpielo bien
para quitar el polvo y aceite. Pegue la etiqueta en
la superficie del transmisor (Figura C). Seleccione
el idioma que más se habla en la casa. Si no sabe
cuál es, use la etiqueta en inglés.
2. Si une télécommande est utilisée pour contrôler
le foyer, nettoyez la soigneusement pour éliminer
la poussière et les traces de graisse ou d’huile.
Collez l’étiquette sur le boîtier de la télé-
commande (FigureC).Choisissezlalanguequiest
3. If you are unable to locate the labels, please call
LennoxHearthProductsoryournearestLennox
Hearth Products dealer to receive additional
safety instruction labels free of charge.
principalementparléedanslarésidenceduproprié- 3. Si no puede encontrar las etiquetas, sírvase llamar
taire. En cas de doute, collez l’étiquette en anglais.
3. Si vous ne trouvez pas les étiquettes, veuillez
appelerLennoxHearthProductsouvotredistribu-
teur Lennox Hearth Products local pour recevoir
gratuitement des étiquettes supplémentaires.
a Lennox Hearth Products o al distribuidor de
Lennox Hearth Products más cercano para recibir
etiquetasdeinstruccionesdeseguridadadicionales
gratuitas.
Cat. No. H8024 Replacement Label Kit
Juego de etiquetas de repuesto - Nº de cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Étiquettes de remplacement, n° cat. H8024
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
LENNOX HEARTH PRODUCTS
1-800-9-LENNOX
Note: English is red text on clear label. French and
Spanish are white text on black label.
Nota: La etiqueta en inglés es transparente con texto
rojo. Las etiquetas en francés y español son negras
con texto blanco.
Remarque : Le texte anglais est rouge sur un support
transparent. Le texte français et espagnol est blanc
sur un support noir.
DIAGRAMMES DES ÉTIQUETTES DE SÉCURITÉ / DIAGRAMAS DE ETIQUETAS DE SEGURIDAD / SAFETY LABEL DIAGRAMS
WARNING
Hot Fireplace Will Cause
Severe Burns
ADVERTENCIA
La chimenea caliente
causará quemaduras graves
Nunca permita que los niños
toquen el vidrio ni otras
partes de la chimenea
AVERTISSEMENT
Un foyer chaud peut causer
de graves brûlures
Ne laissez jamais un enfant
toucher à la vitre ou à toutes
autres parties du foyer
Never Allow Children to
Touch Glass or other Fire-
place Parts
Figure C
Figure B
Figure A
ADVERTENCIA
La chimenea caliente cau-
sará quemaduras graves
Nunca permita que los niños
toquen el vidrio ni otras
partes de la chimenea
A
VE
Un foyer Rud peut causer
TISSEMENT
de graves brûlure
Ne laissez jamais un enfant
toutes
autres parties du foyer
toucher
à
la vitre ou
à
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
WHAT TO DO IF YOU SMELL GAS:
Pre-Lighting Checklist
DO NOT try to light the appliance.
Be sure to check these items before the initial lighting of the
insert:
DO NOT touch any electric switch,
DO NOT use any phone in the building. Immediately call your
gas supplier from a neighbor's phone. Follow the gas supplier's
instructions. If you cannot reach your gas supplier, call the fire
department.
cThe insert gas label corresponds to the gas supply available
- that is "natural gas" for natural gas or "LP gas" for LP gas.
cGas pressure has been checked carefully - see Page 13.
cAll gas fittings have been checked for leaks.
cAll clearances to combustibles have been met-see Page 9.
cAll combustible materials have been removed from the area in
front of the insert.
cAll vented areas of the insert face are unobstructed.
cHouse is ventilated to clear initial paint curing odors - see Page
18.
cAll packaging materials have been removed from the firebox.
cWhile insert is cool, fingerprints or other marks have been
cleanedfromanygoldornickelsurfaceswithdenaturedalcohol
andasoftcloth.Marksleftonthesesurfacesmaybecomeetched
into the finish if not removed prior to burning the unit.
cLog set have been installed.
C. Use only your hand to push in or turn the gas control knob.
Never use any tool. If the knob will not push in or turn by hand,
don't try to repair it, call a qualified service technician. Force or
attempted repair may result in a fire or explosion.
D. DO NOT use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been under water.
OPERATING INSTRUCTIONS
CAUTION: YOUR SUPERIOR™ GAS INSERT MUST ALWAYS BE
OPERATED WITH GLASS IN PLACE.
cThe glass door is in place and is properly sealed.
Lighting Instructions
STOP!! Read the safety information above before proceeding.
1. Open the lower door. Make sure gas supply shut-off cocks are
open and ON/OFF rocker switch is "OFF." If equipped with a
thermostat, set it to the lowest setting.
The following is a copy of the operating and lighting instructions
found with each insert:
2. Turn off all electrical power to the appliance.
FOR YOUR SAFETY READ BEFORE OPERATING
3. Push in gas cock dial slightly and turn clockwise
"OFF."
to
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, INJURY, OR LOSS OF LIFE.
Note: Dial cannot be turned from "PILOT" to "OFF" unless dial
is pushed in slightly. Do not force.
4. Wait five minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Follow "B"
above. If you don't smell gas continue.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN,FURNITURE,GASOLINE,ANDOTHERLIQUIDSWITH
FLAMMABLEVAPORSAWAY.NEVEROPERATEUNITWITHGLASS
OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT.
A. This appliance is equipped with a piezo ignition device to light
the pilot. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING, smell around the appliance area for gas.
Be sure to smell next to the floor, because some gas is heavier
than air and will settle on the floor.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Locate the pilot by looking over the top of the left front log. A
blue flame will be seen when the pilot is lit.
WARNINGS
6. Turn the gas control knob counter-clockwise
"PILOT" position.
to the
• Operation of this appliance when not connected
to a properly installed and maintained venting
system can result in carbon monoxide (CO)
poisoning and possible death.
• Carbon monoxide poisoning – early signs of
carbon monoxide poisoning resemble the flu
with headaches, dizziness, or nausea. If you
havethesesigns, getfreshairatonce! Havethe
heater inspected by a qualified service techni-
cian. Some people are more affected by carbon
monoxide than others. These include pregnant
women, people with heart or lung disease or
anemia, those under the influence of alcohol,
and those at high altitudes.
7.Pushtheknoballthewayinandholdinthatposition.Immediately
light the pilot by pressing the igniter button several times until
pilot is lit. Continue to hold the knob in for about 30 seconds
after the pilot is lit. Release knob and it will pop back out. Pilot
should remain lit. If it goes out, repeat steps 4-8 holding knob
in an additional 15 seconds after pilot is lit. If knob does not
pop out when released, stop and immediately call your service
technicianorgassupplier.Ifthepilotwillnotstaylitafterseveral
tries, turn the gas control knob to "OFF" and call your service
technician or your gas supplier.
8. After pilot is lit, turn gas control knob counter-clockwise
to "ON." Knob can only be turned to "ON" if the knob
has popped out.
9. To turn burner on, turn "ON/OFF" rocker switch to "ON" or
set the thermostat to the desired temperature above room
temperature.
10. Adjust the flame height (and heat output) by turning the flame
Robertshaw Millivolt Gas Valve
height knob clockwise
for full flame and counter-
clockwise for reduced flame.
TH
TP
11. Turn on the electric power to the appliance and set the blower
to the desired air flow after it turns on when the appliance
reaches operating temperature.
TP/TH
GasControlKnob
(Pilot/On/Off)
FlameHeightControl
Knob(HI/LO)
TO TURN OFF GAS TO APPLIANCE
1. Turn off the "ON/OFF" rocker switch and/or thermostat (if
installed) to its lowest setting.
2. Turn off electric power to the appliance if service is to be
performed.
PiezoIgniter
Allumeur
ON/OFFSwitch
Interrupteur
3. Push in gas control knob slightly and turn clockwise
to "OFF." Do not force.
This appliance needs fresh air for safe operation and must be
installed so there are provisions for adequate combustion and
ventilation air.
Gas Pilot Hood
Veilleuse à gaz
Thermopile
Igniter (electrode)
Allumeur
Thermocouple
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to "OFF" or adjust
the thermostat (if installed) to a setting below room temperature.
The pilot will remain lit for future burner ignition. For complete
shutdown, see "TO TURN OFF GAS TO APPLIANCE" above.
Pilot Assembly
Figure 16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Flame Color and Behavior
Quiet Operation
YourSDVIgasinsertisdesignedformaximumheatingefficiency.Therefore,
upon lighting of the main burner the flames will be semi-transparent or
“bluish.” After 10-20 minutes of operation the logs will heat up and the
flames will become a yellow/orange color.
As the SDVI gas insert is burning, a number of normal operational
sounds may be heard. The flow of gas through the gas valve and orifice
may make a rushing or whistling noise. If this noise is objectionable,
it can be reduced by turning down the flame. Turning down the flame
can reduce total heat output by more than 30%. When the blower turns
on, the sound of rushing air may be heard. The blower sounds may be
reduced by adjusting the speed control located on the blower assembly.
Also, a slight clicking sound may be heard as the gas valve or blower
switch turn on and off.
Adjusting the insert to cause the flames to turn orange sooner may result
in poor combustion, sooting, and a hazardous situation. See the drawing
to the right showing proper flame appearance.
When testing for proper operation - If an optional thermostat is installed
adjust it to its highest temperature setting. Visually determine that main
burner gas is burning properly: i.e., no floating, lifting or flashback.
Adjust the primary air shutter(s) as required. Check for proper main
burner operation at both high and low flame.
Blower Operation
Your SDVI gas insert comes equipped with a 150 CFM blower with a
variable speed control and an automatic temperature activated On/Off
snap switch.
Burner Flame Appearance
Operation:
Soot above
Flame Tip
1. Plug the blower power cord into a grounded (three-prong) outlet. This
appliance is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into
a properly grounded three-prong receptacle. Do not cut or remove
the grounding prong from this plug.
2. After the insert warms up, the blower will turn on if the speed control
(located at the right below the firebox) is left in the "ON" position. The
blower will not operate until the insert is warm.
Soot at
No Soot at
Flame Tip
Flame Tip
Dark Orange
Flame
Semi-Transparent
Yellow Flame
Ports on Pan
Burner Assembly
No Blue Flame
Center
Blue Flame
Center
PROPERLY
BURNING FLAME
IMPROPERLY
BURNING FLAME
3. Once the blower turns on, turn the knob to the desired speed. No
further adjustment is necessary.
4. If you do not wish to have the blower on, turn the knob until it clicks
into the "OFF" position.
Figure 17
Paint Curing
Optional Wall Thermostat
This insert has been painted with a high temperature metallic stove paint.
It leaves the factory dry to the touch, but finishes curing as the insert
is used. Fire the insert four successive times for ten minutes each time
with a five minute cool down between each firing. Ventilate the house
during these first firings as the paint gives off an unpleasant odor. It is
recommended that persons sensitive to an imbalance in the indoor air
quality avoid the insert during the curing process.
If an optional wall thermostat is to be installed, install the thermostat per
the manufacturers instructions (provided with the thermostat). Failure
to follow manufacturers instructions could result in a malfunction. Pay
special attention to the thermostat location requirements. If the loca-
tion requirements are not adhered to the appliance, erratic operation or
failure may occur.
Do not mount the thermostat where it may be affected by:
• Radiant heat from this appliance, fireplaces, sun or other heat
sources.
• Drafts or dead spots behind doors or in corners.
• Hot or cold air from ducts.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Options
Thermostat Wire
Wire Size
12 Gage
14 Gage
16 Gage
18 Gage
20 Gage
Maximum Length
100 Feet
64 Feet
The rocker switch on your SDVI gas insert is used to turn the burner on
and off while the pilot is on. The rocker switch can be installed in the hole
in the right side of the top surround panel or in the hole in the panel to
the left of the igniter button. The hole in the panel is covered by a label
which must be carefully cut out before installing the rocker switch. The
switch must be disconnected from the coil of wire to which it is attached,
the plastic nut unscrewed from the back side of the switch, and then the
switch can be inserted into the hole at either location. If the switch is to
be located in the surround, route the wire behind the igniter bracket and
through the hole in the lower right side of the insert. Attach the three
plastic adhesive wire restraints (found in the bag in the firebox) to the
side surround panel. Feed the wire through these restraints and up to the
switch. Care should be taken to ensure the wire does not come in contact
with the hot surfaces of the firebox. Reconnect the wires to the switch.
40 Feet
25 Feet
16 Feet
Millivolt Control System
This fireplace operates on a millivolt control system. As such, no addi-
tional power supply is needed for the fireplace to heat. The pilot assembly
contains a thermocouple, that when heated by the pilot flame, generates
electricity (millivolts- mV=1/1000 of a volt) which opens a valve allow-
ing gas to flow to the pilot assembly. The pilot assembly also contains a
thermopile, that when heated by the pilot flame, generates electricity that
flows to terminal #1 (labeled THTP) on the gas valve. When the electricity
is conducted from terminal #1 through the on/off switch, thermostat,
or receiver of the remote control to terminal #3 (labeled TH) on the gas
valve, the main burner will ignite.
A wall-mounted switch, a millivolt wall thermostat, or a remote control,
can be used to supplement the rocker switch. The gas valve is powered
by millivolts generated by the pilot assembly. This millivolt system is very
sensitive to electrical resistance, therefore, make sure all connections are
tight, clean, and free from corrosion. Do not splice any millivolt wires.
Consult the table on this page to determine the proper gage of wire for
the thermostat or wall switch connections. This table refers to the total
length of the wire (out to the switch and back). The thermostat must
be a millivolt type. A 24-volt furnace thermostat will not work. Never
hook up household current - 120 Volts - to the millivolt system. It is not
recommended to hook up any more than two switches to the insert (for
example a rocker switch and a wall thermostat). Additional switches may
affect the system resistance and increase the chance of the burner not
igniting. Follow the instructions included with the thermostat or remote
control for wiring.
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat et
dangereux.
The thermostat, remote control, and rocker switch will turn the burner
on and off independently. Be sure to set the rocker switch to the “OFF”
position when using the thermostat or remote control and set the ther-
mostat or remote control to the lowest temperature when you wish to
use the rocker switch only, otherwise one may override the other. If a
remote thermostat is to be used with the insert, do not place the receiver
under the firebox.
Millivolt Control Schematic
Pilot Hood
Sparker
Piezo Igniter
Wiring Terminals
Thermopile
Thermocouple
TH
Pilot Assembly
TP
TH/TP
Pilot Gas Line
White
Brown
Gas Inlet
ON/OFF Rocker Switch, Thermo-
stat, or Remote Thermostat
Figure 18
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Millivolt and System Checks
MAINTENANCE AND SERVICING
Check
Test
To
Test
Connect
Meter
Leads to
Terminals
Thermostat Meter Read-
Connects
ing
Should Be
WARNING
A
B
C
Complete
System
2 & 3
1 & 2
2 & 3
Closed
Open
100 MV
or More
Turn off gas and electrical power to the fireplace
and allow it to cool before cleaning or servicing
the appliance.
Thermopile
Output
Greater Than
325 MV
System
Resistance
Closed
2.5 Ohms
CAUTION: Wear gloves and safety glasses for protection while
doing required maintenance.
Verify proper operation after servicing.
Proper Pilot Flame Appearance
S'assurer que l'appareil fonctionne adéquatement une fois
l'entretien terminé.
Maintenance Checklist
The following should only be performed by a qualified service
technician.
1. Annual inspection should be made and the following checks per-
formed:
oWhen unit is cool, remove glass and inspect burner for dirt, soot,
and lint accumulations, and remove if necessary. If excessive soot
accumulation is present on burner, have a qualified service technician
adjust the burner for proper combustion.
o Clean inside of glass with gas fireplace glass cleaner. NEVER attempt
to remove or clean the glass when the unit is hot.
o Check the hot air outlet vents for lint or other accumulations. Never
block or restrict vent openings, obstruct flow of ventilation air, or use
vents other than those approved for use with the SDVI gas insert.
Figure 19
o Check that the chimney and its outlet are open and free of soot, block-
age, or debris.
o Check gaskets once a year. Gaskets must be tight. Replace if neces-
sary.
o Inspect the pilot system for proper flame. NEVER ADJUST THE PILOT
untilafterthegaspressurehasbeencheckedandthesupplylineshave
been completely bled (this may take an hour or more when bleeding
through the pilot). All pilots are checked and burned at the factory
prior to shipment. The pilot adjustment screw is located below the
ON/OFF/PILOT control knob. Remove the pilot adjusting cover with
a flat-bladed screwdriver to access the pilot adjusting screw. Adjust
the pilot screw to properly size the flames. The flames should directly
contact the thermopile and extend across the main burner ports. Be
careful not to back the screw out of its threads. Replace the cover and
check for gas leaks using a gas leak test solution.
o Check that the area around the insert is kept clear and is free of
combustible materials, gasoline, and other flammable vapors and
liquids.
o Check the millivolt system as per the table on this page.
2. The viewing glass should be cleaned periodically (see Glass Main-
tenance).
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Glass Door
Glass Door Removal
To remove the glass door, pull forward and up on the top latches. Lift the
glass door up and off the lower spring latch. Be careful not to damage or
scratchtheglasswhilehandling.Toreinstalltheglass,reversetheremoval
steps. Do not operate the insert with the glass removed.
WARNING
• Do not attempt to substitute the materials used
on these doors, or replace cracked or broken
glass.
Glass Door Cleaning And Maintenance
• Handle this glass with extreme care! Glass is
susceptible to damage – Do not scratch or handle
roughly while reinstalling the glass door frame.
• The glass door(s) of this appliance must only be
replaced as a complete unit as provided by the
manufacturer. Do not attempt to replace broken,
cracked or chipped glass separately.
Cleaning: Do not remove or clean the glass door when hot. When cool,
the glass may be cleaned with a clean, soft cloth and a household glass
cleaner. For cleaning white condensation from the interior glass, use a
gas fireplace glass cleaner available from your dealer. Use of caustic or
abrasivecleanersmaydamagetheglass. DONOTspraycommercialglass
cleaner with ammonia on the door and glass gasket as it may dissolve
the gasket glue.
• Do not attempt to touch the front enclosure glass
with your hands while the appliance is in use.
Repair: If the glass is broken in the glass door, the entire door (metal
frame, gasket and glass) should be replaced as a unit. This replacement
glass door is available from your Lennox Hearth Products dealer. Do not
use substitute parts or materials. The glass is neo-ceramic and alterna-
tive types must not be used.
WARNING
Do not operate appliance with the glass front
removed, cracked or broken.
NOTE: BE CAREFUL NOT TO SPRAY COMMERCIAL GLASS
CLEANER WITH AMMONIA ON GASKET AREA OF DOOR. AM-
MONIA WILL DISSOLVE GASKET GLUE.
AVERTISSEMENT
Ne pas utiliser l'appareil si le panneau frontal en
verre n'est pas en place, est craqué ou brisé.
Only doors certified with the appliance shall be used.
Seules des portes certifiées pour cet appareil doivent être
utilisées.
(A) Spring Handle Latches
(B) Door Mounting Plates
CAUTION: DO NOT abuse glass door by striking or slamming
shut.
Do not remove glass door while the appliance is hot.
Figure 20
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical Requirements:
Fuel Conversion
This gas insert operates without an outside power source, however the
blower requires a 120 Volt electrical service outlet. This appliance, when
installed, must be electrically grounded in accordance with local codes,
or in the absence of local codes, the National Electrical Code ANSI/NFPA
70 - latest edition. (See Operating Options for thermostat and ON/OFF
switch information).
ConvertingyourSDVIgasinsertbetweennaturalgasandLPcanbeaccom-
plished by installing a conversion kit (valve regulator and burner orifice).
Only a qualified service technician should perform the conversion.
Conversion Kit: Please see instructions provided with conver-
sion kit.
Blower Removal
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
Unplug the power supply cord from the electrical outlet prior to remov-
ing the blower. The blower can be accessed through the back wall of
the firebox.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat
et dangereux.
Removetheinsertface,glassdoorandlogset.Alloftheseitemsarefragile
sohandlethemwithcare. Next, removethenineallenheadscrewsaround
the outside of the panel fastened to the back wall of the firebox. Rotate the
top of this panel toward the front, remove the two wires connected to the
blower, and then lift the panel with the blower attached out of the firebox.
To reinstall the blower, repeat these steps in the reverse order.
Blower Wiring Schematic
Blower Snap Switch
Green (Ground)
Speed Control
Black (Hot)
From Power Source
White (Neutral)
White
Black
Blower
Figure 21
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in
the “ON” position.
IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting
should only be accomplished by a qualified service technician.
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
Thin black coating (soot)
forms on the viewing
glass, logs, or firebox
Improper log or ember
placement
See Log Set Installation on Page 11. If there is soot in one specific location, the
rockwool below this location needs to be adjusted. This can be done by pulling embers
forward slightly. If the flames have soot tails, the shutter will need to be opened.
Improper air shutter
setting
If sooting continues open air shutter (see Air Shutter Adjustment on Pages 13 and 14).
Not enough combus-
tion air
Check for debris obstructing air flow in valve compartment under insert or in front of
lower venting.
Humming or whistling
coming from insert.
Normal operating noise See Quiet Operation on Page 18. The noise may be reduced by slightly turning down the
flame. Turning the flame down will reduce the heat output of the insert.
Obstructed orifice
opening
If noise is excessive or is “whistling” have your gas supplier check the regulator and
orifices and replace if necessary.
A change in flame appear- A change in gas pres-
ance or burner operation. sure
Have your gas supplier check for correct gas pressure (7" W.C. / po. C.E. [1.74 kPa] natu-
ral gas; 11" W.C. / po. C.E. [2.74 kPa] LP gas). NOTE: NEVER BLOCK OR OBSTRUCT AIR
INTAKE OR OUTLET VENTS.
Improper ember place-
ment
See Log Set Installation on Page 11.
Spark igniter will not light No gas supplied to unit Check gas supply. To purge, hold in gas cock on valve for 1-2 minutes and try again.
pilot after repeated tries.
or air in line
Defective igniter (no
spark at electrode)
Check for spark at electrode and pilot, if no spark and electrode wire is properly con-
nected, replace igniter and igniter wire.
Defective or misaligned Using a match, light pilot. If pilot lights, turn off pilot and trigger the igniter again. If pilot
electrode at pilot (spark lights, an intermittent gas/air supply may be the problem, if longer purge will not light
at electrode)
- check gap between electrode and pilot - should be 1/8 inch (3 mm) to have a strong
spark. If OK, replace pilot.
Pilot will not stay lit after
carefully following lighting
instructions.
Low gas inlet pressure
Defective thermopile
Check inlet pressure and adjust pilot if necessary.
Be sure wire connections from thermopile are tight at gas valve terminals.
Either rocker switch or thermostat wires may be grounded. Remove wires from valve
terminals. If pilot stays lit, trace switch wiring for a ground. May be grounded to insert or
gas supply.
Check open circuit millivolt output of thermopile. Reading should be greater than 325mV.
Also check thermopile wire for kinks that can cause loss of mV. Replace faulty thermopile
if wire is okay and reading is less than 325mV.
Defective automatic
valve operator
Turn valve knob to “ON” and thermostat (if installed) to 90º. Millivolt meter should read
greater than 100 mV. If reading is OK and burner does not turn on, replace gas valve
(qualified service technician only).
Main burner will not burn. Pilot has gone out
See Lighting Instructions.
Rocker switch, thermo- Disconnect rocker switch and thermostat wires at terminals 1 and 3 on valve. Jumper
stat, or wires defective
across from 1 to 3 with pilot lit. If burner comes on either rocker switch, thermostat, or
wiring is not functioning.
Thermopile may not be
generating sufficient
millivolts
Check thermopile with millivolt meter (see Maintenance and Servicing), recheck symp-
tom #2.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACEMENT PARTS - MODEL SDVI
ACCESSORIES
Controls
Cat. No.
Description
Remote
Control
Wall
Thermostat
H6033
Cassette Assembly, NG (if LP, also requires H5464
conversion kit)
H6010
H5922
H5938
Main Burner Assembly
Pilot Assembly, Convertible NG or LP
Cat. No.
70005
Model
RT-AC
Description
Gas Control Valve, NG (if LP, also requires H5941
regulator kit)
Remote Thermostat AC
(ref. form #775280M)
H5939
H5941
H5965
H5964
H6013
H5875
H5655
H5744
H6007
H5745
H4635
H5660
H5977
H5730
H5869
H5863
H5864
H5990
H5989
H5839
Regulator, NG
H0251
RCL-STAT
Remote Control, RCL-STAT, Deluxe
Thermostat DC (ref. form #750129M)
Regulator, LP
Orifice, Main Burner, NG #41
Orifice, Main Burner, LP #53
Blower w/Mounting Bracket
Blower Snap Switch
Blower Speed Control (rheostat)
On/Off Switch
H4635
75273
DWTK
Wall Thermostat, Digital
GASINS-RSCP-B Round Black On/Off Switch Cover Plate
Gas Conversion Kits
On/Off Switch Wires
Piezo Igniter
H5464
H5465
MED-CK-NG to LP
MED-CK-LP to NG
Conversion Kit NG to LP
(ref. form #775246M)
Wall Thermostat, Digital
Power Cord (ref. form #506033-04)
Blower Wire
Conversion Kit LP to NG
(ref. form #775237M)
Speed Control Wire (for rheostat)
Log Set
Bag of Embers (volcanic stone)
Bag of Rockwool
Touch-Up Paint Kit
I
Firebox Door w/Glass
Hardware Package
70K99
Touch-Up Paint, Metallic Black (12 oz aerosol)
TSPK-B
Log Set Support
Contact an Authorized Lennox Hearth Products dealer to obtain any of
these parts. Never use substitute materials. Use of non-approved parts
can result in poor performance and safety hazards.
Finish Panels / Front Supports
75264
MED-ZC-SPPT "ZC Lower Finish Panel/Trad Face
Support, * Requires Trim Piece below"
(ref. form #775257M)
75251
GFHKET-B
Extended Side Trim Kit, Black
(ref. form #775208M)
WARNING
Failure to position the parts in accordance with these
diagrams or failure to use only parts specifically
approved with this appliance may result in property
damage or personal injury.
AVERTISSEMENT
Risque de dommages ou de blessures si les pièces
ne sont pas installées conformément à ces schémas
et ou si des pièces autres que celles spécifiquement
approuvées avec cet appareil sont utilisées.
24
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Download from Www.Somanuals.com. All Manuals Search And Download.
Face / Surround Panel Kits
(Required) - Includes Black Face, Surround, and Black Trim
4 Gear clamps
Termination
Cap
Cat. No.
Model
Description
Arched Black Face, Surround
(27" x 39"), and Black Trim
Vent Kits
H7014
SDVI-A-B
Flashing
Arched Brushed Nickel Face, Surround
(27" x 39"), and Black Trim
H7015
H7016
SDVI-A-BRN
SDVI-A-BKN
Arched Black Nickel Face, Surround
(27" x 39"), and Black Trim
H0909
TKDVI
FKDVI
TKDVI
Flex Liner Kit, DVI 3” X 35’ (requires 2, one for
exhaust and one for intake)
Termination Kit, DVI (termination cap and
flashing)
DV3FK35
DV3FK35
Flex Liner and Termination Kit, 3" X 35'
(includes two flex liners, termination cap and
four gear clamps)
NOTE: The form numbers referenced are the part numbers of the
instruction sheets included in kits.
Arched Face
Barrier Screen Kit
(ref. form #506033-27)
d
C
oole
en
or
Scre
U
ntil
e
Fram
l
a
s
s,
M
etal
reas
u
c
h
G
t
h
e
s
e
A
ot
T
o
Do
C
hildre
N
n
to
T
ouch
u
•
e
B
o
w
ever
r
All
eve
se
Cau
S
N
Will
lace
Firep
Hot
ARNING
W
H7726
MED/SDVI-BS Barrier Screen Kit
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
SAFETY / LISTING LABEL
SERIAL
NO.
MODEL
MODÈLE
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS
UTILISER AVEC DU COMBUSTIBLE SOLIDE
SDVI
SDVI
Portland
US
TESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION
ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE
INSTALLÉ SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE
SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS
CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR.
CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ
DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE
MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES
TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.
Report No. / Número de Rapport
050-S-18b-5
AUBURN, WA., USA 98071
FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT
CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
LISTED VENTED GAS FIREPLACE HEATER - FIREPLACE INSERT - NOT FOR USE WITH SOLID FUEL
TESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI
Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED
IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING
FIREPLACES ONLY - MASONRY OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS.
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN
AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE
OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED
KIT IS USED.
DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.
SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE
CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
Model: SDVI
GAZ NATUREL
GAZ PROPANE
25000/18500
10,0
SPÉCIFICATIONS
ENTRÉE MAX/MIN BTU/HR 0-4500 pi (0-1370 M)*
PRESSION À LA SORTIE (IN. WC/C.E.)
25000/17500
DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
3,5
5,0
#41
IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY.
IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST
EDITION (CANADA).
PRESSION MINIMUM D’ENTRÉE DU GAZ (IN. WC/C.E.)
ORIFICE (DMS) 0-4500 pi (0-1370 M)*
10,5
#53
* L’APPAREIL PRÉUSINÉ EST MUNI D’ÉQUIPEMENT POUR 0-2000 PIEDS (0-610 M). AU CANADA 0-4500 PIEDS (0-1370M).
SPÉCIFICATIONS ÉLECTRIQUE 120 VCA, 60 HZ, MOINS DE 2 AMPÈRES
Model: SDVI
NATURAL GAS
LP GAS
25,000/18,500
10.0
RATINGS
MAX/MIN INPUT BTUH 0-2,000 FT (0-610 M)*
MANIFOLD PRESSURE (IN. WC)
CHEMINÉE - ÉVACUATION :INSTALLER AVEC DE L’ÉVENT À GAZ DE TYPE B-VENT OU UN CONDUIT FLEXIBLE À SIMPLE
PAROI HOMOLOGUÉ COMME TUBAGE.
CET APPAREIL DOIT ÊTRE RELIÉ À UN SYSTÈME D’ÉVACUATION TEL QUE SPÉCIFIÉ DANS LE MANUEL D’INSTALLATION DU
FABRICANT.
EN ALTITUDE, AU-DELÀ DE 2000 PI/610 M, (AU CANADA 0-4500 PI/0-1370M) LA CAPACITÉ ÉNERGÉTIQUE DE L’APPAREIL
DIMINUE DE QUATRE (4)% POUR CHAQUE 1000 PI (405 M).
25,000/17,500
3.5
5.0
MINIMUM INLET PRESSURE (IN. WC)
ORIFICE (DMS) 0-2,000 FT (0-610 M)*
10.5
#41
#53
DÉGAGEMENTS AUX COMBUSTIBLES
E
F
= Dessus du foyer à partir de la base
= Mur latéral à partir du centre du foyer
31.5” (800mm)
25.5 (648mm)
(991mm)
*UNIT FACTORY EQUIPPED FOR 0-2000 FT/0-610 M, IN CANADA 0-4500 FT/0-1370 M
ELECTRICAL RATING: 120 VAC, 60 HZ, LESS THAN 2 AMPS
”
DÉGAGEMENTS MINIMUMS
*J = 10.5” (267mm) manteau de foyer à partir de la base 39
* Voir le manuel d’entretien pour les informatinos supplémentaires reliées
aux distances à respecter pour le manteau de foyer
”
MANTEAU
DE FOYER
CHIMNEY - USE WITH B-VENT CHIMNEY OR SINGLE WALL GAS VENT FLEX CHIMNEY LINER LISTED TO UL 1777 OR ULC S635.
THIS APPLIANCE MUST BE PROPERLY CONNECTED TO A VENTING SYSTEM IN ACCORDANCE WITH THE MANUFACTURER’S
INSTALLATION INSTRUCTIONS.
FOR ALTITUDES ABOVE 2,000 FT/610M (IN CANADA 4500 FT/1370M) DE-RATE THE APPLIANCE BY FOUR (4)% FOR EVERY
1,000 FT (405 M).
F
PIÈCE DE
FINITION
J
DIMENSIONS MINIMUMS DE FOYER REQUISES
A = 29.75” (756mm) Ouverture avant
E
C
L
Note: Extension d’âtre fabriqué avec
B = 17.50” (445mm) Hauteur
3/8” (10mm) minimum de matériaux
non-combustible ou équivalent
possédant un facteur k de 0.84.
C = 19.00” (483mm) Largeur arrière
D = 16.00” (406mm) Profondeur du foyer
MINIMUM CLEARANCES TO COMBUSTIBLES
H
E = 31.5” (800mm) from Top Facing to Bottom of Insert
MINIMUM CLEARANCES
G
F = 25.5” (648mm) from Center of Glass to Side Facing or Side Wall
*J = 39” (991mm) from 10.5” (267mm) Mantel to Bottom of Insert
PROTECTION DU FOYER
G = Extension d’âtre min. devant
G = le foyer
H = Distance verticale de la base de
H = l’appareil aux combustibles
MANTEL
TRIM
* See owner’s manual for additional mantel clearances and options
G
H
13”(330mm) 10”(254mm)
0”(0mm) 2”(21mm)
0”(0mm)
4”(102mm)
MINIMUM FIREPLACE SIZES REQUIRED
A=29.75” (756mm) Front Opening
B=17.50” (445mm) Height
C=19.00” (483mm) Rear Width
D=16.00” (406mm) Fireplace Depth
HEARTH PROTECTION
G = Minimum Hearth Protection
G = from Front of Insert
H = Vertical Distance from Insert
H = Bottom to Combustible Material
F
Note: Hearth protection to be
min. 3/8” (10mm) thick non-
combustible or equivalent, with
a k factor of .84.
J
E
C
L
DANGER:
CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES
H
ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS
LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES
VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT
TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU
VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE
PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ
PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.
G
G
H
13”(330mm) 10”(254mm)
0”(0mm) 2”(21mm)
0”(0mm)
4”(102mm)
CAUTION:
HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS
AWAY. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING
INSTRUCTIONS ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS
APPLIANCE ONLY. DO NOT OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
AVERTISSEMENT: UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE
RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ.
RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN
INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED
WITH THIS APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED
INSTALLER, SERVICE AGENCY OR GAS SUPPLIER.
DATE OF MANUFACTURE / DATE DE FABRICATION
JUL AUG SEP OCT NOV DEC
JAN
FEB MAR APR MAY JUN
2010 2011 2012 2013
JANV FEVR MARS AVR MAI JUIN JUIL AOÛT SEPT OCT NOV DEC
Part No./ No. pièce #580039-01 Rev. NC, 03/2008
IGN
DO NOT REMOVE OR COVER THIS LABEL
N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
LIGHTING LABEL
FOR YOUR SAFETY READ BEFORE OPERATING
POUR VOTRE SÉCURITÉ, LIRE AVANT L’ALLUMAGE
WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, INJURY OR LOSS OF LIFE.
AVERTISSEMENT: SI VOUS NE RESPECTEZ PAS RIGOUREUSEMENT LES INSTRUCTIONS CI-DESSOUS, VOUS POURRIEZ ENCOURIR UN RISQUE D’INCENDIE ET/OU
D’EXPLOSION QUI POURRAIENT CAUSER DES DOMMANGES MATÉRIELS ET CORPORELS POUVANT ENTRAÎNER LA MORT.
CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH
FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT.
DANGER: CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES
ET RIDEAUX. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES.
A. This appliance is equipped with a piezo ignition device to light the pilot. When lighting the pilot, follow these instructions exactly.
A. Cet appareil utilise un système d’allumage par étincelle (allumeur Piézo-électrique) pour allumer la veilleuse. Assurez-vous de suivre
rigoureusement les instructions d’allumage de la veilleuse.
B. AVANT D’ALLUMER L’APPAREIL, assurez-vous qu’il n’y a pas d’odeur de gaz près de l’appareil ni près du sol car certains gaz plus
lourds que l’air auraient tendance à s’y accumuler en cas de fuite.
B. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
•
•
•
•
DO NOT try to light the appliance.
•
•
•
•
N’ALLUMEZ aucun appareil.
DO NOT touch any electric switch; do not use any phone in the building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Ne touchez aucune prise électrique; N’utilisez aucun téléphone dans votre édifice.
Sortez de la maison. À partir d’un autre endroit, appelez immédiatement votre fournisseur de gaz et suivez les directives.
S’il est impossible de joindre le distributeur du gaz, appelez les pompiers.
C. Use only your hand to push in or turn the gas control knob. Never use any tool. If the knob will not push in or turn by hand, don't try
to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.
C. N’utilisez aucun outil pour tourner ou pousser le dispositif de contrôle du gaz. Si vous ne pouvez le faire manuellement, n’essayez
pas de réparer l’appareil. Appelez un technicien de service qualifié. Si vous tentez de forcer ou réparer le dispositif de contrôle du gaz
vous pourriez encourir un risque d’incendie et/ou d’explosion.
D. N’utilisez pas cet appareil si une de ses composantes a été émergée dans l’eau. Appelez immédiatement un technicien de service
qualifié et reconnu afin qu’il inspecte et remplace au besoin toutes pièces du système qui auraient été en contact avec l’eau.
D. DO NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control which has been under water.
OPERATING INSTRUCTIONS
ALLUMAGE
DANGER: VOTRE APPAREIL AU GAZ SUPERIOR™ DOIT ÊTRE OPÉRÉ AVEC DES PORTES DE VERRE.
ATTENTION! Lisez les consignes de sécurité ci-dessous avant d’opérer votre appareil.
CAUTION: YOUR SUPERIOR™ GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE.
STOP! Read the safety information above before proceeding.
Robertshaw Millivolt Gas Valve
RobertShaw Vanne Gaz Millivolt
1. Ouvrir la porte du bas. Assurez-vous que l’alimentation en gaz est
équippé d’un thermostat, placez-le à la température la plus basse.
2. Couper le courant électrique qui alimente l’appareil.
à
la position Fermée “OFF”. Si l’appareil est
1. Open the lower door. Make sure gas supply shut-off cocks are open and ON/OFF
Rocker Switch is “OFF”. If equipped with a thermostat, set it to the lowest setting.
2. Turn off all electrical power to the appliance.
TH
TP
3. Push in Gas Control Knob slightly and turn clockwise
NOTE: Knob cannot be turned from “PILOT” to “OFF” unless Knob is pushed in
slightly. Do not force.
4. Wait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” above.
If you don’t smell gas continue.
to “OFF”.
3. Enfoncez légèrement le bouton de contrôle du gaz et tournez-le dans le sens des aiguilles d’une montre
NOTE: Le bouton de contrôle du gaz ne peut être tourné de la position “PILOT” à “OFF” sans qu’une légère pression ne soit appliquée.
4. Attendez au moins 5 minutes pour que le gaz qui se trouve dans la chambre de combustion puissse s’échapper. Si vous sentez une
odeur de gaz ARRÊTEZ! Référez-vous à la section B ci-dessus. Si vous ne sentez pas d’odeur de gaz, allez à la prochaine étape.
5. Vous pouvez localiser le pilote aussi en regardant par dessus la bûches gauche. Une flamme bleue est visible lorsque le veilleuse est
allumée.
à la position “OFF”.
TP/TH
5. Locate the pilot by looking over the top of the front left log. Blue flame will be
seen when the pilot is lit.
GasControlKnob
(Pilot/On/Off)
FlameHeightControlKnob
(HI/LO)
6. Tournez le bouton de contrôle de gaz dans le sens inverse des aiguilles d’une montre
pour le placer sur “PILOT”.
6. Turn the gas control knob counterclockwise
to the “PILOT” position.
Boutondecontrôle
(Veilleuse/Ouverte/Fermée)
-LO/HI+
7. Cet appareil de chauffage est equipé d’un système d’allumage par étincelle (allumeur Piézo-électirque), devant être utilisé pour
l’allumage de la veilleuse. Poussez complètement le bouton de contrôle du gaz et le maintenir dans cette position. Appuyez
immédiatement sur le bouton (allumeur Piézo-électrique) situé à gauche du robinet de contrôle du gaz.L’étincelle produite par
l’allumeur Piézo-électrique doit allumer la veilleuse. Continuez à maintenir le bouton de contrôle dans cette position pendant environ 30
secondes après l’allumage de la veilleuse. Relâchez le bouton de contrôle du gaz qui reviendra à la position initiale. La veilleuse doit
rester allumée. Répétez les étapes 4 à 8 pendant 15 secondes supplémentaires si la veilleuse s’éteind.
7. Push the knob all the way in and hold in that position. Immediately light the pilot by
pressing the ignitor button several times until pilot is lit. Continue to hold the knob
in for about 30 seconds after the pilot is lit. Release knob and it will pop back out.
Pilot should remain lit. If it goes out, repeat steps 4-8 holding knob in an additional 15 seconds after
pilot is lit.
(CommandeDeTailleDeFlamme)
ON/OFFSwitch
Interrupteur
PiezoIgniter
Allumeur
•
•
If knob does not pop out when released, stop and immediately call your service technician or gas
supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service
technician or your gas supplier.
•
Si le bouton de contrôle du gaz ne revient pas à la position initiale une fois relâché, appeler immédiatement un technicien qualifié ou
votre distributeur de gaz.
•
Si la veileuse ne reste pas allumée après plusieurs essais, tournez le bouton de contrôle du gaz à la position “OFF” et appelez
immédiatement un technicien qualifié ou votre distributeur de gaz.
Millivolt Pilot
8. After pilot is lit, turn gas control counterclockwise
knob has popped out.
9. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature
above room temperature.
to “ON”. Knob can only be turned “ON” if the
8. Lorsque la veilleuse est allumée, tournez le bouton de contrôle du gaz dans le sens invers des aiguilles d’une montre
placer à la position “ON”. Le bouton de contrôle peut-être tourné à la position “ON” seulement si il n’est plus enfoncé.
9. Pour allumer le brûleur, mettre l’interrupteur à la position “ON” ou ajustez le thermostat à la température souhaitée.
pour le
Gas Pilot Hood
Veilleuse à gaz
Igniter
(electrode)
Allumeur
Thermopile
10. Adjust the flame height (and heat output) by turning the flame height knob clockwise
for
10. Ajustez la flamme et la température souhaitée en tournant le bouton de réglage de la flamme dans les sens des aiguille d’une montre
reduced flame and counterclockwise
for full flame.
pour l’abaisser et dans le sens contraire
pour l’augmenter.
11. Turn on all electrical power to the appliance.
12. Set the blower to the desired air flow after it turns on when the appliance reaches operating temperature.
11. Allumez l’alimentation électrique de l’appareil.
12. Ajustez le ventilateur au volume désiré lorsque l’appareil aura atteint la température de fonctionnement.
POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL
TO TURN OFF GAS TO APPLIANCE
1. Turn off the “ON/OFF” rocker switch and/or thermostat (if installed).
1. Fermez l’interrupteur et/ou le thermostat «MARCHE/ARRÊT».
2. Coupez l’alimentation électrique de l’appareil si vous prévoyez en faire le service.
2. Turn off electric power to the appliance if service is to be performed.
3. Tournez le bouton de commande du gaz dans le sens des aiguilles d’une montre
à “OFF”. Ne le forcez pas.
3. Turn gas control knob clockwise
to "OFF". Do not force.
Cet appareil a besoin d’air frais pour opérer sécritairement et doit être installé pour qu’il y ait un apport en air suffisant. Référez-
vous aux manuels d’entretien et d’installation fournis avec l’appareil.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air. See Installation and Operation Manual accompanying appliance.
AVERTISSEMENT: Une installation inadéquate, un mauvais ajustement, une altération ou toutes autres modifications
inappropriés pourraient entraîner des blessures physiques et/ou des dommanges matériels. Référez-vous au guide
d’utilisation fourni avec ce foyer. Pour assistance ou information supplémentaires contactez un installateur qualifié,
un agent de service ou un fournisseur de gaz.
Si vous opérez cet appareil sans qu’il ne soit correctement raccordé à un conduit d’évacuation, vous pourriez risquer d’être
empoisonné au monoxyde de carbone (CO) ce qui pourrait entraîner des conséquences grave ou la mort.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. For assistance or additional information, consult a
qualified installer, service agency or your gas supplier.
Operation of this appliance when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.
SHUTDOWN PROCEDURE
1. To turn off the burner, switch the rocker switch to “OFF” or adjust the thermostat to a setting below room temperature
(if installed). The pilot will remain lit for future burner ignition.
PROCÉDURE D’ARRÊT
1. Pour arrêter le brûleur, mettre l’interrupteur
à
la position “OFF” ou ajustez le thermostat
à
une température en dessous de la
température ambiante. La veilleuse restera allumée pour permettre un alummage ultérieur.
#580039-01 Rev. NC, 03/2008
IGN
For complete shutdown: See “TO TURN OFF GAS TO APPLIANCE” above.
Pour un arrêt complet: Consultez la procédure ci-dessus «POUR COUPER L’ALIMENTATION EN GAZ DE L’APPAREIL».
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Normally, all parts should be ordered through your LHP distributor or
dealer. Parts will be shipped at prevailing prices at time of order.
WARRANTY
Yourgasinsertiscoveredbyalimitedwarranty(providedwithappliance).
Please read the warranty to be familiar with its coverage.
When ordering repair parts, always give the following information:
1. The model number of the appliance.
2. The serial number of the appliance.
3. The part number.
Retain this manual. File it with your other documents for future refer-
ence.
4. The description of the part.
5. The quantity required.
PRODUCT REFERENCE INFORMATION
6. The installation date of the appliance.
We recommend that you record the following important information
about your appliance. Please contact your LHP dealer for any questions
or concerns. For the number of your nearest LHP dealer, please call
1-800-9-LENNOX.
If you encounter any problems or have any questions concerning the
installation or application of this system, please contact your dealer.
LHP
REPLACEMENT PARTS
1508 Elm Hill Pike, Suite 108
Nashville, TN 37210
See Page 24 for a complete replacement parts list. Use only parts sup-
plied from the manufacturer.
Your Appliance's Model Number _______________________________________
Your Fireplace Insert’s Serial Number ___________________________________
The Date On Which Your Fireplace Insert Was Installed______________________
The Type of Gas Your Fireplace Insert Uses_______________________________
Your Dealer's Name _________________________________________________
Fuel Type (Check one)
c
Natural Gas
c
Propane Gas (LP)
�
LHP reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor
for fireplace code information.
Printed in U.S.A. © 2008 LHP
LHP
P/N 506056-01 REV. C 03/2010
1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210