Sun Microsystems Server X6440 User Manual

Sun Blade X6440 Server Module  
Product Notes  
Version 2.0  
Sun Microsystems, Inc.  
Part No. 820-3965-15, Rev. A  
November 2009  
Submit comments about this document by clicking the Feedback[+] link at: http://docs.sun.com  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sun Blade X6440 Server Module  
Product Notes  
This document contains late-breaking information and issues for the Sun Blade™  
The following is covered in these product notes:  
“General Information” on page 2  
“Sun Blade X6440 Server Module Tools & Drivers DVD” on page 4  
“Latest Firmware Updates” on page 4  
“Newly Supported Features” on page 5  
“Hardware and BIOS Issues” on page 6  
“Sun Installation Assistant Issues” on page 9  
“Integrated Lights Out Manager Issues” on page 13  
“Diagnostics Issues” on page 18  
“Operating System Issues” on page 19  
“Solaris Issues” on page 20  
“Linux Issues” on page 21  
“Windows Issues” on page 24  
“Sun StorageTek RAID Expansion Module (REM) Issues” on page 25  
“LSI RAID Expansion Module (REM) Issues” on page 26  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Information  
Support and Patches for Sun Blade Server  
Modules  
Support information for the Sun Blade X6440 server module is available at:  
Supported Operating Systems  
The following is a list of the minimum versions of supported operating systems for  
the Sun Blade X6440 server module:  
Solaris x86 10 05/08, 64-bit  
Solaris x86 10 10/08, 64-bit  
Solaris x86 10 05/09, 64-bit  
OpenSolaris 2009.06  
Red Hat Enterprise Linux (RHEL) 4.6 and later, 32-bit/64-bit  
RHEL 5.1 and later, 64-bit  
Suse Linux Enterprise Server (SLES) 9 SP4, 64-bit (Not supported in SIA 2.3.8)  
SLES 10 SP2, 64-bit  
SLES 11 64-bit  
VMware ESX 3.5 U2 and later, and ESX 4.0  
VMware ESXi 3.5 and ESXi 4.0  
Windows Server 2003 Enterprise SP2, 32-bit/64-bit  
Windows Server 2008 Enterprise SP2, 32-bit/64-bit  
Windows Server 2008 R2 (Not supported in SIA)  
2
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Documentation  
Support documentation for the Sun Blade X6440 server module:  
Sun Blade X6440 Server Module Installation Guide (820-3961)  
Sun Blade X6440 Server Module Product Notes (820-3965)  
Sun Blade X6440 Server Module Operating Systems Installation Guide (820-3962)  
Sun Blade X6440 Server Module Windows Operating System Installation Guide  
(820-3963)  
Sun Installation Assistant for Windows and Linux User’s Guide (820-3357)  
Sun Blade X6440 Server Module Getting Started Guide (820-3960)  
Sun ILOM Supplement for Sun Blade X6440 Server Module (820-3967)  
Sun ILOM 3.0 Supplement for Sun Blade X6440 Server Module (821-0746)  
Sun ILOM 3.0 Documentation Collection:  
Sun Integrated Lights Out Manager (ILOM) 3.0 Getting Started Guide (820-5523)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Feature Updates and Release Notes  
(820-7329)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Concepts Guide (820-6410)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Web Interface Procedures Guide  
(820-6411)  
Sun Integrated Lights Out Manager (ILOM) 3.0 CLI Procedures Guide (820-6412)  
Sun Integrated Lights Out Manager (ILOM) 3.0 SMNP and IPMI Procedures Guide  
(820-6413)  
Sun Integrated Lights Out Manager 2.0 User’s Guide (820-1188)  
Sun Blade X6440 Server Module Service Manual (820-3964)  
Sun Blade X6440 Server Module Safety and Compliance Guide (820-4412)  
These and other Sun Blade server module documents are available at  
Note – As of the ILOM 3.0.6 release, the Sun Integrated Lights Out Manager (ILOM)  
3.0 SNMP and IPMI Procedures Guide has been renamed as the Sun Integrated Lights  
Out Manager (ILOM) 3.0 Management Protocols Reference Guide.  
Sun Blade X6440 Server Module Product Notes  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sun Blade X6440 Server Module  
Tools & Drivers DVD  
The Sun Blade X6440 Server Module Tools & Drivers DVD contains several software  
applications and utilities for use with your Sun Blade X6440 server module. This  
section describes the applications and utilities and refers you to the associated  
readme text files where you can find procedures for running them.  
ILOM SP update. Used to update the SP firmware; the readme text file is located  
in <dvd_drive>:\remoteflash\Firmware_Update.txt.  
SP recovery utility. Used to recover from corrupt SP firmware; the readme text  
file is located in <dvd_drive>:\recovery\readme.txt.  
Create a Windows 2003 OS Installation CD. Used to create a reburn CD (W2K3  
CD with all required drivers); the readme text file is located in  
<dvd_drive>:\utilities\reburn\readme.txt.  
Note – This utility can be performed on a Windows-based system or a  
Linux/Solaris-based system.  
Windows Autorun menu. Simply insert the Tools & Drivers DVD into the X6440  
USB CD/DVD, or mount it via ILOM remote KVMS. Then perform any of the  
following operations:  
Install Windows server drivers  
Create a Windows reburn CD  
Access links to sun.com and associated documentation  
Solaris/Linux post OS driver update. Used to update Intel Ethernet and AST2000  
drivers (if applicable); the install.sh script file is located in  
<dvd_drive>:\drivers\linux\red_hat\install.sh  
<dvd_drive>:\drivers\linux\suse\install.sh  
<dvd_drive>:\drivers\sx86\install.sh.  
Latest Firmware Updates  
latest firmware versions.  
4
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
The following new features are supported as of supplemental software release 2.0:  
Integrated Lights Out Manager 3.0  
Sun ILOM Remote Console Lock  
Sun ILOM Power Management  
Integrated Lights Out Manager 3.0  
The Sun Blade X6440 server module supports Integrated Lights Out Manager  
(ILOM) 3.0 on the service processor (SP) module. For information and instructions  
on using ILOM 3.0 with the Sun Blade X6440 server module, see the ILOM 3.0  
Documentation Collection and the associated ILOM Supplement for the Sun Blade  
X6440 server module:  
Sun Integrated Lights Out Manager (ILOM) 3.0 Getting Started Guide (820-5523)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Feature Updates and Release Notes  
(820-7329)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Concepts Guide (820-6410)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Web Interface Procedures Guide  
(820-6411)  
Sun Integrated Lights Out Manager (ILOM) 3.0 CLI Procedures Guide (820-6412)  
Sun Integrated Lights Out Manager (ILOM) 3.0 SMNP and IPMI Procedures Guide  
(820-6413)  
Sun Integrated Lights Out Manager (ILOM) 3.0 Supplement for Sun Blade X6440  
Server Module (821-0746)  
The ILOM 3.0 Documentation Collection is available at:  
Note – As of the ILOM 3.0.6 release, the Sun Integrated Lights Out Manager (ILOM)  
3.0 SNMP and IPMI Procedures Guide has been renamed as the Sun Integrated Lights  
Out Manager (ILOM) 3.0 Management Protocols Reference Guide.  
Sun Blade X6440 Server Module Product Notes  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Sun ILOM Remote Console Lock  
The Sun Blade X6440 server module supports the Sun ILOM Remote Console lock.  
The Sun ILOM Remote Console lock feature enhances your system security by  
enabling you to lock your computer when terminating a Sun ILOM Remote Console  
session. For more information and instructions for using the lock feature, see the Sun  
Integrated Lights Out Manager (ILOM) 3.0 Feature Updates and Release Notes (820-7329).  
Sun ILOM Power Management  
The Sun Blade X6440 server module supports Sun ILOM power management  
features. Sun ILOM power management features enable you to monitor and manage  
your system’s power consumption. For more information and instructions for using  
ILOM power management features, see the Sun Integrated Lights Out Manager (ILOM)  
3.0 Feature Updates and Release Notes (820-7329).  
The following issues apply to the Sun Blade X6440 server module hardware and/or  
BIOS:  
“ILOM BIOS settings issue” on page 7  
“ILOM IP address is not updated” on page 7  
“PEM fault light illuminates after hot-inserting into the server module” on page 7  
“BIOS does not accept the ipmitool persistent boot order change command” on  
page 8  
“BIOS does not accept the ipmitool clear CMOS command” on page 8  
“Certain devices’ boot option ROM fails to load” on page 9  
“NEM model X4238 requires latest BIOS firmware” on page 9  
6
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
ILOM BIOS settings issue  
If ILOM is set to use a DHCP assigned IP address, and the DHCP server is offline,  
wait until the DHCP server is online before attempting to reboot. Issuing a reboot or  
manually changing from DHCP to a static IP address will result in incorrect gateway  
and IP address settings to be recorded. Once DHCP is restored, the original IP  
address will be assigned.  
Workaround:  
Do not reboot the server until DHCP is restored, or connect a terminal to the serial  
console’s NET Management port and manually assign a static IP address if access is  
urgently required to ILOM.  
ILOM IP address is not updated  
If the ILOM IP address is changed via the LAN configuration in the BIOS, the IP  
address will not update. The old IP address is displayed. It is recommended to  
change the IP address via ILOM.  
If you choose to change the ILOM IP address via BIOS, exit and re-enter the LAN  
configuration screen to see the changes.  
PEM fault light illuminates after hot-inserting into  
the server module  
The Mellanox Infiniband PCI-E expansion module fault light may illuminate after it  
has been hot-inserted into a server module running the Solaris OS. The fault light  
will not clear itself until the system is rebooted.  
Workaround:  
Update to the latest BIOS that is included on the Tools and Driver v1.1 DVD-ROM or  
a later version.  
Power LED issue  
The green LED Power LED incorrectly stops blinking and turns solid green once  
ILOM detects that the power is good. The green Power LED should stop blinking  
and turn solid only when the operating system is ready.  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
       
Blade server module fails to link up at 1GbE  
If the Sun Blade X6440 server module is inserted into certain slots in the Sun Blade  
6048 chassis, it fails to link up at 1GbE with the X5196A-Z Sun Blade 6048 Infiniband  
Switched Network Express Module (NEM). This issue occurs primarily on the inner  
slots (BL3-BL8). These slots can only link up at 100Mb.  
Workaround:  
Use the outer slots (BL0-BL2 and BL9-BL11) to link up at 1GbE.  
This issue is under investigation.  
Power supply redundancy must be set to non  
redundant mode  
If more than eight X6440 server modules are to be inserted into the Sun Blade 6000  
chassis (which can hold a maximum of 10 server modules), power supply  
redundancy must be set to non redundant mode. This will allow all X6440 server  
modules in the chassis to be powered on simultaneously.  
BIOS does not accept the ipmitool persistent  
boot order change command  
The BIOS fails to permanently modify the boot order after sending the ipmitool  
persistent boot order change command.  
Workaround:  
This issue is fixed in the Tools & Drivers DVD 1.2 and later software release.  
BIOS does not accept the ipmitool clear CMOS  
command  
The BIOS fails to clear all setup settings and load system defaults after sending the  
ipmitool clear CMOS command.  
Workaround:  
This issue is fixed in the Tools & Drivers DVD 1.2 and later software release.  
8
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Certain devices’ boot option ROM fails to load  
A shadow ROM space issue exists when multiple bootable devices are installed in  
the system. Not all devices’ bootable option ROMs will successfully load.  
Workaround:  
This issue is fixed in the Tools & Drivers DVD 1.2 and later software release. Users  
will have the option to select which option ROM to load in the BIOS setup window.  
NEM model X4238 requires latest BIOS firmware  
Network express module (NEM) model X4238 requires the latest BIOS firmware to  
work properly. The required BIOS firmware (version 1.2) is located on the Sun Blade  
X6440 Server Module Tools & Drivers DVD.  
The following issues apply to the Sun Installation Assistant (SIA) software:  
page 10  
page 10  
“SIA will not install FEM drivers for Windows 2003” on page 11  
“RHEL installed using SIA reports a MPT Fusion ctl drivers error” on page 11  
“SIA displays ILOM version as Unknown” on page 11  
“SIA displays incorrect chassis information” on page 11  
“SIA does not display storage controllers” on page 12  
“SIA displays error when installing using PXE method” on page 12  
“SIA Update function fails” on page 12  
“SIA does not install operating systems via PXE server” on page 13  
Sun Blade X6440 Server Module Product Notes  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
LVM partitioning is not supported when  
installing SLES 10 SP2 operating system  
Change Request ID: 6780100  
If LVM disk partitioning is selected when installing the SLES 10 SP2 operating  
system using SIA, the installation will fail because the platform drivers will not  
install correctly.  
Workaround: None  
SLES 9 SP4 operating system is not supported  
using SIA  
Change Request ID: 6771799  
Do not use SIA to install the SLES 9 SP4 as SIA does not support this operating  
system.  
Workaround: None  
SIA will not install Infiniband drivers for  
Windows operating systems  
Change Request ID: 6771790 and 6771803  
Infiniband (IB) drivers for the IB passthru FEM (fabric express module) and IB NEM  
(network express module) will not install correctly when installing Windows  
2003/2008 using SIA.  
Workaround: None  
SIA will not install FEM/NEM drivers for 32-bit  
Linux operating systems  
Change Request ID: 676068  
Model x1029A fabric express module (FEM) and model x4236A network express  
module (NEM) drivers will not install correctly when installing Linux (such as  
RHEL 32-bit and SLES 10 32-bit) using SIA.  
10  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Workaround: None  
SIA will not install FEM drivers for Windows 2003  
Change Request ID: 6769562  
If SIA is used to install Windows 2003 on a system that contains the model x1029 A  
FEM, the associated device will be highlighted with a yellow question mark in the  
Windows Device Manager, indicating that the drivers are not installed correctly.  
Workaround: None  
RHEL installed using SIA reports a MPT Fusion  
ctl drivers error  
Change Request ID: 6737853  
If SIA is used to install RHEL 4.6 on a system that does not contain a Sun Blade I/O  
Expansion Module II (mptsas) controller, the following error will occur when RHEL  
boots:  
starting MPT Fusion ctl drivers FAILED  
This error is harmless and can be ignored.  
Workaround: None  
This issue will be fixed in future software release.  
SIA displays ILOM version as Unknown  
Change Request ID: 6878691  
When installing the Linux operating system using SIA version 2.3.8, the ILOM  
version is displayed as “Unknown” in the System Information screen.  
This issue will be fixed in future software release.  
SIA displays incorrect chassis information  
Change Request ID: 6878692  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
       
When installing the Linux operating system using SIA version 2.3.8, the System  
Information screen displays incorrect information for the chassis type, serial number,  
and version number.  
This issue will be fixed in future software release.  
SIA does not display storage controllers  
Change Request ID: 6878694  
When installing the Linux operating system using SIA version 2.3.8, the System  
Information screen does not display system storage controllers.  
This issue will be fixed in future software release.  
SIA displays error when installing using PXE  
method  
Change Request ID: 6879495  
When installing some operating systems using SIA version 2.3.8, SIA might display  
the following error message while SIA is determining the OS:  
“Provide a valid URL”  
This message can be ignored. The OS installation will complete successfully.  
This issue will be fixed in future software release.  
SIA Update function fails  
Change Request ID: 6875404  
When selecting the SIA Update function in SIA 2.3.8, SIA might display the  
following error message:  
“SIA update failed…”  
This issue will be fixed in future software release.  
12  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
SIA does not install operating systems via PXE  
server  
Change Request ID: 6876850  
When using SIA version 2.3.8 to install OSes via a PXE server, SIA displays the  
following error message during the OS installation:  
Error enabling swap device sda2: Invalid argument  
This error affects all OS installations that SIA supports. This error occurs after the  
disk partition phase of the OS installation and might indicate that the swap device  
has not been initialized.  
Workaround:  
Add parameter iommu=soft in PXE server.  
“Delaying BIOS Upgrade During Firmware Update Can Corrupt BIOS” on  
page 14  
on page 15  
“Solaris Remote Console session requires Java plugin” on page 15  
“Service processor might take up to 3 minutes to start” on page 16  
“Error message appears during service processor startup” on page 17  
“FRU data for the hard disk drives is not passed via ipmitool” on page 17  
“impitool session info all command fails” on page 17  
“Hard disk error message in the SP event log” on page 18  
“DIMM SPD data are reported incorrectly in the FRU data” on page 18  
For more information about the ILOM, see the online Sun Integrated Lights Out  
Manager 2.0 User’s Guide (820-1188) or the Sun Integrated Lights Out Manager 3.0  
Documentation Collection.  
Sun Blade X6440 Server Module Product Notes  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Delaying BIOS Upgrade During Firmware Update  
Can Corrupt BIOS  
The ILOM SP firmware upgrade procedure includes the Delay BIOS Update  
option, which delays the BIOS update until the host is reset. This option allows you  
to update the firmware without resetting the host.  
The following scenarios can cause your BIOS to corrupt:  
If you select the Delay BIOS Update option, then power down the host and  
remove the server module from its slot before the BIOS update is complete.  
If you select the Delay BIOS Update option, then power down the host and  
power on the server module immediately before the BIOS update is complete.  
If you start another SP firmware update before the BIOS update has been  
completed.  
Workaround:  
Do not select the Delay BIOS Update option. If you choose to use the Delay  
BIOS Update option:  
1. Do not remove the server module from its slot until after the host has been reset  
and the BIOS update is complete.  
2. If you are powering off the system for the first time after ILOM is upgraded, do  
not power on the host until the BIOS update is complete.  
3. Do not attempt to update the SP firmware until after the host has been reset and  
the BIOS update is complete.  
Note – The BIOS update after host power-off might take 3-4 minutes.  
14  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Minimum Supported Browsers  
TABLE 1 shows the minimum supported browser versions for running the Integrated  
Lights Out Manager (ILOM) web interface for the Sun Blade X6440 server module  
on Solaris and Linux operating systems.  
TABLE 1  
Version Numbers for Browsers  
Solaris x86  
1.7  
RHEL 32-bit RHEL 64-bit SLES 32-bit  
SLES 64-bit  
1.7.13  
Windows  
Mozilla  
Firefox  
1.7.12  
1.0.7  
1.7.13  
1.5.0.4  
N/A  
1.7.8  
N/A  
1.5.0.4  
6
1.5.0.4  
N/A  
1.5.0.4  
N/A  
1.5.0.4  
Internet  
Explorer  
N/A  
N/A  
No warning when password length is exceeded  
No errors or warnings are issued to the user when the user exceeds the 16-character  
limit for passwords via the web interface.  
Workaround:  
This issue is scheduled to be fixed in a future ILOM firmware release.  
KVMS authentication does not work with remote  
authentication mechanisms  
User authentication for KVMS sessions cannot be performed using any of the remote  
user-authentication mechanisms, such as RADIUS, LDAP, or ActiveDirectory.  
Workaround:  
This issue is scheduled to be fixed in a future ILOM firmware release.  
Solaris Remote Console session requires Java  
plugin  
When you launch a Remote Console session on a Solaris system, the system will  
prompt you for a decision regarding the javaRKVM.jnlp file. You have the  
following two options:  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
         
If you are logged in as root, choose to open the file with its default application.  
–or–  
If you are logged in as a user (not root), do the following:  
1. Choose the option to save the file.  
2. Download the javaRKVM.jnlp file and run it manually.  
The download manager will display the location of this file.  
3. Move the javaRKVM.jnlp file to the /tmp directory.  
% mv /location_of_javaRKVM.JNLP/javaRKVM.JNLP /tmp  
Where location_of_javaRKVM.JNLP is the directory where javaRKVM.JNLP  
resides.  
4. To find the location of the javaws application, enter the following in a  
terminal window:  
% which javaws  
5. Execute the following command from the terminal window:  
% /location_of_javaws/javaws /tmp/javaRKVM.JNLP  
Where location_of_javaws is the directory where javaws resides.  
Example:  
Assuming that the javaws application is run from the /usr/bin directory, the  
following command will open a Remote Console session:  
% /usr/bin/javaws /tmp/javaRKVM.JNLP  
Once the remote console window is closed, the /tmp/javaRKVM.jnlp is removed.  
Service processor might take up to 3 minutes to  
start  
On server blade insertion or server processor (SP) reset, the SP might take up to 3  
minutes to start. The SP will not function during this time, and the port 80 reader  
will toggle between 55 and AA.  
16  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Error message appears during service processor  
startup  
The following error message may appear during service processor (SP) startup:  
Mike driver.  
insmod: cannot insert  
‘/lib/modules/2.6.15.4/misc/mtd_mike/mike.ko’: No such device (-  
1): No such device  
modprobe: failed to load module mike  
This issue is being investigated. It is safe to ignore this message.  
FRU data for the hard disk drives is not passed  
via ipmitool  
FRU data for the hard disk drives (HDD) is not passed via ipmitool. For example,  
the following error message is received:  
FRU Device Description : HDD0 (ID 24)  
Device not present (Requested sensor, data, or record not  
found)  
FRU Device Description : HDD1 (ID 25)  
Device not present (Requested sensor, data, or record not  
found)  
Workaround:  
This issue is scheduled to be fixed in a future ILOM/BIOS release.  
impitool session info all command fails  
The impitool session info all command fails. For example, the following error  
message is received:  
impitool -H 129.148.53.83 -U root -P changeme session info all  
Get session Info command failed  
Workaround:  
This issue is scheduled to be fixed in a future ILOM/BIOS release.  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
     
Hard disk error message in the SP event log  
The following error message might appear in the SP event log when no hard disk is  
installed.  
System Firmware Error | Unrecoverable hard-disk controller  
failure | Asserted  
Workaround:  
It is safe to ignore this error message.  
DIMM SPD data are reported incorrectly in the  
FRU data  
Certain DDRII DIMMs are displayed incorrectly in the SP FRU data. For example,  
DDRII 800 MHz DIMMs are listed only as 444 MHz DIMMs in the FRU data. This is  
a FRU data discrepancy and it does not impact memory and system performance.  
Workaround:  
This issue is scheduled to be fixed in a future ILOM firmware release.  
This section contains the following:  
“Pc-Check Diagnostics Software Issues” on page 18  
“Hard disk information is unknown” on page 19  
“Serial port test fails” on page 19  
“SunVTS Diagnostics Software Issues” on page 19  
“SunVTS I/O port test fails” on page 19  
Pc-Check Diagnostics Software Issues  
The following issues apply to the Pc-Check diagnostics software.  
18  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Hard disk information is unknown  
When running the Pc-Check hard disk diagnostics, the hard disk information, hard  
disk firmware, and serial number are listed as unknown.  
Serial port test fails  
The Pc-Check serial port test fails because Pc-Check does not support the RJ-45 serial  
port connector.  
SunVTS Diagnostics Software Issues  
The following issue applies to SunVTS™ diagnostics software.  
SunVTS I/O port test fails  
The SunVTS I/O port test fails when the system is in exerciser mode. This occurs  
because the test fails to read written bytes at various baud rates when the system is  
under heavy stress.  
Workaround:  
Run the SunVTS I/O port test in standalone or in component mode.  
This section contains the following:  
“Solaris Issues” on page 20  
Warning message might appear during startup” on page 20  
“Solaris OS installation halts during the installation” on page 20  
“Linux Issues” on page 21  
“USB device errors reported in Red Hat 5.1” on page 21  
“Unable to hot plug PCI-E expansion modules (PEM)” on page 21  
“PCI BIOS error message might appear” on page 22  
“IGB error message might appear” on page 22  
“Error messages might appear in SLES 10 OS dmesg” on page 22  
Sun Blade X6440 Server Module Product Notes  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
         
“Only 8 of 16 CPU cores being reported” on page 22  
“Post OS driver update script fails to run” on page 23  
“SLES OS driver installation takes a long time to complete” on page 23  
“NIC drivers are not supported by SLES11 OS” on page 23  
“SLES 9 SP4 hangs during installation or startup” on page 23  
“USB devices are not recognized in RHEL 4.7” on page 24  
“Windows Issues” on page 24  
“Windows Autorun does not install drivers” on page 24  
Yellow question mark might appear in Windows Device Manager” on page 25  
“System does not boot from floppy drive image” on page 25  
For a list of minimum supported operating systems, see “Supported Operating  
Systems” on page 2.  
Solaris Issues  
Note – The Sun Blade X6440 is delivered with a preinstalled Solaris OS. This OS is  
set by default to be redirected through the serial console connection (ttya). To change  
this to local monitor/keyboard, use the GRUB menu at boot time, and select the  
VGA option.  
Warning message might appear during startup  
When using a compact flash device, the following warning message might appear  
during Solaris startup:  
WARNING: /pci@0,0/pci-ide@4/ide@0 unable to enable write cache  
targ=0  
It is safe to ignore this message.  
Solaris OS installation halts during the installation  
Change Request ID: 6848353  
When installing the Solaris OS in a system that contains an LSI 1068e B3 HBA, the  
installation halts at the “Configuring Devices” screen. This issue does not occur  
when using other HBA cards in the system.  
20  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
This issue is being investigated.  
Linux Issues  
The following issue applies to Sun Blade X6440 server modules running the  
supported Red Hat Enterprise Linux (RHEL) or SUSE Linux Enterprise Server  
(SLES) operating systems.  
USB device errors reported in Red Hat 5.1  
The following error is generated when a USB device is inserted in the USB ports on  
the Sun Blade X6440 server module:  
usb 1-2; device not accepting address 2, error -71  
This is a RHEL 5.1 issue.  
Workaround:  
You must manually create a new initrd.img file in your current installation:  
1. Open a terminal window.  
2. Navigate to the /boot directory.  
cd /boot  
3. Rename the initrd.img file by typing the command:  
mv initrd-<version>.img initrd-<version>.img.save  
4. Create a new initrd.img file by typing the command:  
mkinitrd initrd-<version>.img <uname - r>  
5. Reboot the server module to effect the changes.  
Unable to hot plug PCI-E expansion modules (PEM)  
The “acpiphp” module is not loaded in the kernel by default.  
Workaround:  
1. Open a terminal window.  
2. Type the command:  
modprobe acpiphp  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
     
3. Insert the PEM in either slot and press the Attn button.  
The PEM is ready to use when the OK LED turns solid green.  
PCI BIOS error message might appear  
The following error message might appear when booting or running the dmesg  
command in RHEL 5.1:  
PCI: BIOS Bug: MCFG area at e0000000 is not E820-reserved  
PCI: Not using MMCONFIG.  
It is safe to ignore this message.  
IGB error message might appear  
The following IGB error message might appear in dmesg:  
igb: 0000:84:00.1: igb_set_interrupt_capability: Failed to  
initialize MSI-X interrupts.  
Failing back to MSI interrupts.  
igb: 0000:84:00.1: igb_set_interrupt_capability: Failed to  
initialize MSI interrupts.  
Failing back to legacy interrupts.  
Both onboard Intel 82575EB network interface cards (NICs) are still functional. It is  
safe to ignore this message. This issue is being investigated.  
Error messages might appear in SLES 10 OS dmesg  
The following error messages might appear in the SLES 10 SP2 64-bit OS dmesg:  
Evaluate _OSC Set fails. Status = 0x0005 aer_init: AER service  
init fails - No ACPI_OSC support aer: probe of  
0000:00:0a.0:pcie01 failed with error 1  
Workaround:  
This issue is being investigated.  
Only 8 of 16 CPU cores being reported  
The Linux operating system only reports 8 CPU cores out of the possible 16 CPU  
cores in the server module. This issue occurs because of a Linux kernel limitation.  
22  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Workaround:  
Install and boot from the largesmp kernel version, which can be found in the  
installation media.  
Post OS driver update script fails to run  
The following error message might display when running the post OS driver  
(install.sh) update script:  
bash ./install.sh: /bin/sh: bad interpreter: Permission denied  
Workaround:  
Run the post OS driver update using the sh install.sh command, or unmount  
and remount the Tools & Drivers DVD manually.  
SLES OS driver installation takes a long time to complete  
Installing SLES OS drivers might take a long time to complete if the host firewall is  
enabled. This issue occurs when running the install.sh script from the Tools &  
Drivers DVD.  
Workaround:  
Disable the host firewall before installing SLES OS drivers.  
NIC drivers are not supported by SLES11 OS  
Change Request ID: 6871270  
The Sun Blade RAID Expansion Module (REM) and Intel 82575 Gigabit Ethernet  
Controller network interface card (NIC) drivers on the Sun Blade X6440 server  
module Tools & Drivers DVD do not work with the SLES11 operating system.  
This issue is being investigated.  
SLES 9 SP4 hangs during installation or startup  
SLES 9 SP4 hangs during installation or startup on systems with over 4 GB of RAM.  
SLES9 SP4 (kernel 2.6.5-7.308) installs correctly on a system with a quad-core AMD  
Opteron processor with over 4 GB of RAM; however, on the initial boot after  
installation, the system hangs.  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
       
Workaround:  
This issue can be resolved by following these steps:  
1. Temporarily limit the memory to less than 4 GB.  
This can be accomplished by physically removing RAM to reduce it to less than 4  
GB.  
Alternately, you can use a boot parameter to limit the memory that is used by  
SLES. The boot parameter is mem=nnnn, where nnnn is equal to a number less  
than 4000.  
2. Install the latest kernel update to version 2.6.5-7.311 or newer.  
After using the above method to limit the memory while the system is installed,  
the kernel can be updated to provide the fixes so that the full amount of memory  
can be used.  
Information about this kernel update and how to download it is available at  
USB devices are not recognized in RHEL 4.7  
The RHEL 4.7 operating system does not recognize USB 2.0 devices. This causes the  
OS installations that use a USB DVD-ROM or ILOM remote KVMS device to fail.  
More details and a fix for this issue can be found at:  
Workaround:  
Either install RHEL 4.7 over a network or install the updated kernel fix from the  
Red Hat web site. Alternatively, you can remove the ehci-hcd.ko module from the  
kernel by typing the rmmod ehci_hcd command from the system prompt.  
Windows Issues  
Windows Autorun does not install drivers  
Windows autorun does not install drivers. This occurs when Windows User Account  
Control is turned on.  
Workaround:  
1. Turn off Windows User Account Control.  
24  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
2. Reboot the system for the changes to take effect.  
3. Run Windows Autorun to install drivers.  
Yellow question mark might appear in Windows Device  
Manager  
A yellow question mark might appear in the Windows Device Manager, denoting  
that drivers are not installed for the following devices:  
Sun Blade Storage SCSI Enclosure Device  
Sun NEM Plus SCSI Enclosure Device  
Workaround:  
Run Windows Update to install the necessary drivers.  
System does not boot from floppy drive image  
The system does not boot Windows from a floppy drive image installation. This  
occurs because the BIOS sets the virtual floppy as the first (top) USB bootable device.  
Workaround:  
1. During system boot, press F2 to enter the BIOS Setup Utility.  
2. From the Boot/USB devices menu, change the device boot order to set the  
virtual CDROM as the first (top) USB bootable device.  
Sun StorageTek RAID Expansion  
Module (REM) Issues  
Use the StorageTek BIOS setup utility  
Before the operating system can use hard disk drives attached to a StorageTek SAS  
controller, the drives must first be initialized and an array created using the  
StorageTek BIOS Setup Utility. The StorageTek BIOS Setup Utility can be accessed by  
pressing the CTRL + A keystroke combination during the server blade power on  
self-test (POST).  
Sun Blade X6440 Server Module Product Notes  
Download from Www.Somanuals.com. All Manuals Search And Download.  
25  
     
This section contains the following LSI RAID REM issues:  
“Extra hard disk drive space required when upgrading to a Mirrored RAID  
configuration” on page 26  
“Upgrade path for data merging” on page 26  
Extra hard disk drive space required when  
upgrading to a Mirrored RAID configuration  
You must have 100 MB of free unpartitioned disk space at the end of the hard disk  
drive if you want to upgrade to a mirrored RAID configuration.  
Upgrade path for data merging  
The only upgrade path that supports data merging is from a single disk to a mirror.  
This is a limitation of the LSI card. If you want to upgrade from a single disk to an  
IME (Integrated Mirror Extension) or an IMS (Integrated Mirror Stripe), the data and  
OS will be lost and a reinstallation and restore will be required.  
26  
Sun Blade X6440 Server Module Product Notes • November 2009  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     

Sentry Industries Clock ATC 20 User Manual
Sharp Flat Panel Television LL H1813 User Manual
Signat Water Heater Powerstream Professional User Manual
Singer Sewing Machine 99K28 User Manual
Sony Ericsson Cell Phone Z550 User Manual
Sony Video Game Headset SBH70 User Manual
Spalding Fitness Equipment M8660411 User Manual
Sterling Plumbing Outdoor Shower 61040110 User Manual
Swann DVR SW242 DAL User Manual
T+A Elektroakustik Speaker AE 14 User Manual