Motor Connector
The motor cable from the micromanipulator has to be inserted to this 7-pin jack on the backside of the case.
Connection to Earth
On the left side of the backside of the case there is an uninsulated 4mm jack. It can be connected to earth, if
necessary.
Trigger Input
There are two BNC-jacks on the rear panel triggering the X-forward/backward movement by positive external TTL-
pulses (rear panel: left/right: forward/backward). Every pulse follows a step movement of the manipulator.
A
continuous movement results, if the frequency of the pulses exceeds 20 Hz. Settings see 'Basic Operation'.
Before opening the cover
disconnect mains.
Special Adjustments
This unit operates on 115 V ac or 230 V ac. The voltage selector is inside the case. To change the range first unplug
the power cord and than open the case (4 screws under the rubber pads on the bottom). Now switch the voltage
selector near the transformer with a screwdriver. In no case adjust the 6 trimmers inside the case.
Note: The fuse must be changed, if the line voltage is changed (see below: 'Fuses')
Fuses
This unit is protected by a slow blow fuse of 50 mA (line voltage 230 V) or by a slow blow fuse of 100 mA (line voltage
115 V), which is easily accessible from the backside of the case. Under the transformer is a thermal fuse (98 °C). This
should only be replaced by the manufacturer.
Piezo Translator
The piezo translator is adjusted very carefully to move only axially. It must be handled with extreme care: Incautious
use of force could impair the adjustment or even destroy the drive. Lateral vibrations are mainly caused by the
repulsion of the piezo translator and depend on the mass distribution of the used basic manipulator. In order to
eliminate these vibrations a second piezo translator has to be mounted in opposite direction to the back of the first
translator and has to be electrically connected to this. A second piezo translator has to be ordered separately.
Holder for Micro Capillaries
For the best operation use only the specially constructed micro- capillary holders. Holders with too much or unevenly
distributed mass cause vibrations and impair operation.
SPECIFICATIONS
POWER SUPPLY
POWER CONSUMPTION
FUSES
∼115/230 Volt 50-60 Hz
6 W
115 Volt T 0.1A / 230Volt T 0.05A (5×
20mm)
98°C
5°C to 40°C
THERMAL FUSE
OPERATING
TEMPERATURE
STORAGE TEMPERATURE
DIMENSIONS
-20°C to 60°C
19×4.7×13.8 cm (7.5×1.85×5.4 in.)
0.68 kg (1.6 lb)
WEIGHT
Download from Www.Somanuals.com. All Manuals Search And Download.
Warranty
Stoelting warrants its products against defects in materials and workmanship according to the
following schedule:
WARRANTY PERIOD
ITEM
Materials
1 YEAR
1 YEAR
Labor
ELECTRONIC CIRCUITRY (microprocessors, resistors,
transistors, integrated circuits, etc.)
1 YEAR
MECHANICAL AND ELECTROMECHANICAL PARTS
(meters, switches, etc.)
1 YEAR
ELECTRODES, CABLES AND ALL OTHER ACCESSORIES 30 DAYS
30 DAYS
Stoelting will, at its option, repair or replace defective items within the specified warranty
period. Modifying or tampering with the instrument or non-factory authorized service during the
warranty period will invalidate the warranty. Shipping costs both to and from the Stoelting
Repair Department will be borne by the customer.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR
IMPLIED.
STOELTING SHALL NOT IN ANY EVENT BE LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES, RESULTING FROM THE USE OR
MISUSE OF ITS PRODUCTS.
THIS DEVICE IS MEANT FOR ANIMAL RESEARCH USE ONLY AND IT IS NOT
INTENDED FOR USE WITH HUMANS. USE OF THIS DEVICE WITH HUMANS
INVALIDATES WARRANTY.
Download from Www.Somanuals.com. All Manuals Search And Download.
|