TRINITRON® COLOR VIDEO MONITOR
BVM-20F1U/20F1E
BVM-20E1U/20E1E
BVM-14F1U/14F1E
BVM-14E1U/14E1E
BVM-14F5U/14F5E
BVM-14E5U/14E5E
[English]
OPERATION MANUAL
1st Edition (Revised 7)
Serial No. 2000001 and Higher
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING: THIS WARNING IS APPLICABLE FOR USA
ONLY.
Note
Be sure to use the supplied power cord for this monitor, or
this monitor may not conform with the FCC Rules or EEC
Directive 89/336/EEC.
If used in USA, use the UL LISTED power cord specified
below.
DO NOT USE ANY OTHER POWER CORD.
Remarque
Utiliser le cordon d’alimentation fourni pour ce moniteur,
sinon il pourrait ne pas être conforme aux règles FCC ou à la
directive CEE 89/336/EEC.
Plug Cap
Parallel blade with ground pin
(NEMA 5-15P Configuration)
Type SVT, three 16 or 18 AWG wires
Less than 2.5 m (8 ft 3 in)
Cord
Length
Rating
Hinweis
Dieser Monitor darf ausschließlich mit dem mitgelieferten
Netzkabel betrieben werden, weil anderenfalls der Monitor
nicht mehr die FCC-Vorschriften oder die EG-Richtlinie 89/
336/EWG erfüllt.
Minimum 10 A, 125 V
Using this unit at a voltage other than 120V may require the
use of a different line cord or attachment plug, or both. To
reduce the risk of fire or electric shock, refer servicing to
qualified service personnel.
Nota
Utilice sin falta el cable eléctrico que viene con este monitor;
de lo contrario el monitor puede no cumplir con los
reglamentos de la FCC o de la directiva 89/336/EEC de la
Comunidad Europea.
For customers in the USA
This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own
expense.
Nota
Assicurarsi di usare il cavo di alimentazione in dotazione per
questo monitor, altrimenti il monitor può non essere
conforme alle norme FCC o alla Direttiva CEE/89/336.
For the customers in the United Kingdom
WARNING
THIS APPARATUS MUST BE EARTHED
IMPORTANT
The wires in this mains lead are coloured in accordance with
the following code:
You are cautioned that any changes or modifications not
expressly approved in this manual could void your authority
to operate this equipment.
Green-and-yellow: Earth
Blue:
Brown:
Neutral
Live
The shielded interface cable recommended in this manual
must be used with this equipment in order to comply with the
limits for a digital device pursuant to Subpart B of Part 15 of
FCC Rules.
As the colours of the wires in the mains lead of this
apparatus may not correspond with the coloured markings
identifying the terminals in your plug proceed as follows:
The wire which is coloured green-and-yellow must be
connected to the terminal in the plug which is marked by the
letter E or by the safety earth symbol Y or coloured green or
green-and-yellow.
Voor de klanten in Nederland
The wire which is coloured blue must be connected to the
terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the
terminal which is marked with the letter L or coloured red.
• Dit apparaat bevat een vast ingebouwde batterij die niet
vervangen hoeft te worden tijdens de levensduur van het
apparaat.
• Raadpleeg uw leverancier indien de batterij toch vervangen
moet worden.
Ensure that your equipment is connected correctly - if you
are in any doubt consult a qualified electrician.
De batterij mag alleen vervangen worden door
vakbekwaam servicepersoneel.
• Gooi de batterij niet weg maar lever deze in als klein
chemisch afval (KCA).
• Lever het apparaat aan het einde van de levensduur in voor
recycling, de batterij zal dan op correcte wijze verwerkt
worden.
Download from Www.Somanuals.com. All Manuals Search And Download.
For the customers in Europe
This product with the CE marking complies with both the
EMC Directive (89/336/EEC) and the Low Voltage Directive
(73/23/EEC) issued by the Commission of the European
Community.
Compliance with these directives implies conformity to the
following European standards:
• EN60950: Product Safety
• EN55103-1: Electromagnetic Interference (Emission)
• EN55103-2: Electromagnetic Susceptibility (Immunity)
This product is intended for use in the following
Electromagnetic Environment(s):
E1 (residential), E2 (commercial and light industrial), E3
(urban outdoors) and E4 (controlled EMC environment, ex.
TV studio).
Pour les clients européens
Ce produit portant la marque CE est conforme à la fois à la
Directive sur la compatibilité électromagnétique (EMC) (89/
336/CEE) et à la Directive sur les basses tensions (73/23/
CEE) émises par la Commission de la Communauté
européenne.
La conformité à ces directives implique la conformité aux
normes européennes suivantes:
• EN60950: Sécurité des produits
• EN55103-1: Interférences électromagnétiques (émission)
• EN55103-2: Sensibilité électromagnétique (immunité)
Ce produit est prévu pour être utilisé dans les
environnements électromagnétiques suivants:
E1 (résidentiel), E2 (commercial et industrie légère), E3
(urbain extérieur) et E4 (environnement EMC contrôlé ex.
studio de télévision).
Für Kunden in Europa
Dieses Produkt besitzt die CE-Kennzeichnung und erfüllt
sowohl die EMV-Direktive (89/336/EEC) als auch die
Direktive Niederspannung (73/23/EEC) der EG-Kommission.
Die Erfüllung dieser Direktiven bedeutet Konformität für die
folgenden Europäischen Normen:
• EN60950: Produktsicherheit
• EN55103-1: Elektromagnetische Interferenz (Emission)
• EN55103-2: Elektromagnetische Empfindlichkeit
(Immunität)
Dieses Produkt ist für den Einsatz unter folgenden
elektromagnetischen Bedingungen ausgelegt:
E1 (Wohnbereich), E2 (kommerzieller und in beschränktem
Maße industrieller Bereich), E3 (Stadtbereich im Freien) und
E4 (kontrollierter EMV-Bereich, z.B. Fernsehstudio).
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Precaution.................................................................................................. 3
Overview .................................................................................................... 4
Features ............................................................................................... 4
Options ................................................................................................ 5
Connector Panel Configuration ........................................................... 7
Location and Function of Parts ............................................................... 9
Front Panel .......................................................................................... 9
Rear Panel ......................................................................................... 15
Chapter 1 Overview
Menu Structure ....................................................................................... 19
Displaying Menus ............................................................................. 19
ADDRESS Menu .............................................................................. 20
Menu Directories ............................................................................... 21
Basic Menu Operations .......................................................................... 22
Menu Operation Buttons ................................................................... 22
Menu Operation................................................................................. 22
Preset Adjustment of the Picture Level Control Knobs
Chapter 2 Menus
— CONTROL PRESET ADJ Menu.............................................. 25
Overview ........................................................................................... 25
Structure of the CONTROL PRESET ADJ Menu [A]....................... 25
Constituent Menus of the CONTROL PRESET ADJ Menu ............. 25
Adjusting the Color Temperature — COLOR TEMP ADJ Menu .... 27
Overview ........................................................................................... 27
Structure of the COLOR TEMP ADJ Menu [B]................................ 28
Constituent Menus of the COLOR TEMP ADJ Menu ...................... 29
Setting the Input Configuration — INPUT CONFIGURATION
Menu ................................................................................................. 33
Overview ........................................................................................... 33
Structure of the SET UP Menu [C] / INPUT CONFIGURATION
Menu [C1] ............................................................................... 34
Constituent Menus of the SET UP / INPUT
CONFIGURATION Menu ...................................................... 35
Assigning the Remote Control Functions — REMOTE Menu .......... 38
Overview ........................................................................................... 38
Structure of the SET UP Menu [C] / REMOTE Menu [C2] .............. 38
Constituent Menus of the SET UP / REMOTE Menu ...................... 39
Setting the Password — PASSWORD Menu ....................................... 40
Overview ........................................................................................... 40
Structure of the SET UP menu [C] / PASSWORD menu [C3] .......... 40
Constituent Menus of the SET UP / PASSWORD Menu.................. 40
Setting the Channel Selection Method and Power-Up Conditions
— SYSTEM CONFIGURATION Menu ....................................... 42
Overview ........................................................................................... 42
Structure of the SET UP Menu [C] / SYSTEM CONFIGURATION
Menu [C4] ............................................................................... 42
Constituent Menus of the SET UP / SYSTEM CONFIGURATION
Menu ....................................................................................... 43
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Setting the Screen Display — ON SCREEN SET Menu..................... 44
Overview ........................................................................................... 44
Structure of the SET UP Menu [C] / ON SCREEN SET
Chapter 2
Menus (Continued)
Menu [C5] ............................................................................... 44
Constituent Menus of the SET UP / ON SCREEN SET Menu......... 44
Convergence Adjustments — ALIGNMENT Menu............................ 46
Overview ........................................................................................... 46
Structure of the SET UP Menu [C] / ALIGNMENT Menu [C6]....... 46
Constituent Menus of the SET UP / ALIGNMENT Menu ............... 46
Using Extended Functions — EXTEND MENU ................................. 48
Overview ........................................................................................... 48
Structure of the SET UP Menu [C] / EXTEND Menu [C7] .............. 48
Constituent Menus of the SET UP / EXTEND Menu ....................... 49
Monitor Memory Card Data Operations — MEMORY CARD
Menu ................................................................................................. 51
Overview ........................................................................................... 51
Structure of the MEMORY CARD Menu [D] ................................... 51
Constituent Menus of the MEMORY CARD Menu ......................... 51
Monitor-to-Monitor Data Copy — COPY Menu ................................ 52
Overview ........................................................................................... 52
Structure of the COPY Menu [E] ...................................................... 52
Constituent Menus of the COPY Menu............................................. 52
Displaying Information About the Monitor — STATUS Menu ......... 53
Overview ........................................................................................... 53
Structure of the STATUS Menu [F]................................................... 53
Constituent Menus of the STATUS Menu......................................... 53
Selecting the Monitor to Control — ADDRESS Menu ....................... 54
Overview ........................................................................................... 54
Displaying the ADDRESS Menu ...................................................... 54
Cancelling the Remote Control Mode............................................... 55
Exiting the ADDRESS Menu ............................................................ 55
Short-cut Function in the ADDRESS Menu ..................................... 55
Chapter 3
Appendix
Specifications........................................................................................... 57
Connection Cable Specifications for Color Temperature Probes ...... 60
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Precaution
On safety
On repacking
• Operate the unit only with a power source as
specified in “Specifications” section.
• The nameplate indicating operating voltage, power
consumption, etc., is located at the rear.
Do not throw away the carton and packing materials.
They make an ideal container which to transport the
unit. When shipping the unit to another location,
repack it as illustrated on the carton.
• Should any solid object or liquid fall into the cabinet,
unplug the unit and have it checked by qualified
personnel before operating it any further.
• Do not drop or place heavy objects on the power
cord. If the power cord is damaged, turn off the
power immediately. It is dangerous to use the unit
with a damaged power cord.
• Unplug the unit from the wall outlet if it is not to be
used for several days or more.
• Disconnect the power cord from the AC outlet by
grasping the plug, not by pulling the cord.
• The socket-outlet shall be installed near the
equipment and shall be easily accessible.
If you have any questions about this unit, contact your
authorized Sony dealer.
On magnetism
• Do not place the unit near any objects or pieces of
equipment which generate magnetism, such as
magnets, speakers, electric clocks, toys using
magnets, health appliances, etc. Magnetism will
cause picture bounce, oscillations or picture
discoloration.
• Also, the picture may become fuzzy or the colors
may not reproduce correctly due to earth magnetism.
This depends on direction that the unit is installed.
This is not equipment failure. In such a case, simply
degauss the unit.
On installation
• Allow adequate air circulation to prevent internal heat
build-up.
Do not place the unit on surfaces (rugs, blankets, etc.)
or near materials (curtains, draperies) that may block
the ventilation holes.
• Do not install the unit in a location near heat sources
such as radiators or air ducts, or in a place subject to
direct sunlight, excessive dust, mechanical vibration
or shock.
On the CRT
• Dust accumulates on the CRT easily. Clean the CRT
when necessary with a soft cloth.
The surface of the CRT is easily scratched; therefore,
do not rub or touch the surface of the CRT
unnecessarily since this may result in a scratched
picture tube.
On cleaning
• If you touch the surface of the CRT, you may feel a
weak electrical shock. This is simply static electricity
that is generated on the surface of the CRT. It will not
affect the human body.
To keep the unit looking brand-new, periodically clean
it with a mild detergent solution. Never use strong
solvents such as thinner or benzine, or abrasive
cleansers since they will damage the cabinet. As a
safety precaution, unplug the unit before cleaning it.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
Setup and adjustment with the monitor
memory card
The BVM-20F1U/20F1E/20E1U/20E1E, BVM-
14F1U/14F1E/14E1U/14E1E and BVM-14F5U/
14F5E/14E5U/14E5E Trinitron®1) Color Video
Monitors are high-performance 20- and 14-inch color
video monitors. They are suitable for television
stations or video production houses, where precise
image reproduction is required.
You can use an optional BKM-12Y Monitor Memory
Card to save and load monitor setup and adjustment
data. If your system includes more than one monitor,
you can use the monitor memory cards to exchange
data between monitors. This makes it easy to put all
monitors in your system into the same setup and
adjustment state.
1) Trinitron® is a registered trademark of Sony
Corporation.
Standard auto alignment system
Decoder chroma and phase adjustment, as well as
color temperature control, may be performed with the
auto alignment system. This makes it possible to
coordinate settings among multiple monitors.
Features
High resolution picture tube
The HR Trinitron picture tube produces a clear, high
resolution image.
Expandable input capability
The input connector configuration may be easily
modified by simply sliding optional decoder adaptors
or input expansion adaptors into input option slots at
the rear of the monitor. The BVM-20F1U/20F1E/
20E1U/20E1E/14F5U/14F5E/14E5U/14E5E may be
fitted with up to four adaptors, and the BVM-14F1U/
14F1E/14E1U/14E1E will accept two.
Resolution at the
center of the picture
Model
Aperture
grille pitch
BVM-20F1U/20F1E 0.30 mm
BVM-20E1U/20E1E 0.25 mm
900 TV lines
1000 TV lines
BVM-14F1U/14F1E 0.25 mm
BVM-14E1U/14E1E 0.22 mm
800 TV lines
900 TV lines
800 TV lines
900 TV lines
BVM-14F5U/14F5E
0.25 mm
4:3/16:9 dual aspect ratio design
BVM-14E5U/14E5E 0.22 mm
The monitors can be changed to either 4:3 or 16:9
aspect ratio with just a simple switching operation. The
screen can be also changed to 4:3 or 16:9 display by
the replacement of a mask (no tools required).
Separate control unit (BVM-20FIU/20FIE/
20EIU/20EIE/14FIU/14FIE/14EIU/14EIE only)
The BVM-20F1U/20F1E/20E1U/20E1E/14F1U/
14F1E/14E1U/14E1E are controlled by a separate
control unit, such as a BKM-10R/11R Monitor Control
Unit. Use of a separate control unit reduces the space
needed for the equipment. With the BVM-20F1U/
20F1E/20E1U/20E1E, it is also possible to attach the
BKM-10R with an optional BKM-32H Monitor
Control Unit Attachment Kit.
Stable color temperature
The internal beam current feedback circuit maintains a
constant color temperature over long periods of time.
Blue-only mode convenient for monitoring
noise
All three CRT cathodes can be driven with a blue
signal, producing a monochrome display. This mode
is convenient for chroma and phase adjustment, and
for monitoring VTR noise.
Controlling monitor groups
Up to 32 monitors can be controlled from this monitor.
First, the built-in menu system is used to assign a
monitor address number to each monitor, divide the
monitors into groups, and assign a group number to
each group. Then you can use this monitor to control
individual monitors or monitor groups simply by
entering monitor address or group numbers. You can
also execute the same operation on all connected
monitors, or use this monitor to put all connected
monitors into the same setup and adjustment state.
Menu operation
The monitor’s various functions and operating
conditions can be set with on-screen menus.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Other features
BKM-14L Auto Setup Probe
• Compatible with the ISR (Interactive Status
Reporting) system.
This probe allows automatic adjustment of this
monitor’s color temperature.
• Has both RS-485 serial remote and relay contact
parallel remote control connectors.
• Built-in safe area display and test signal generator for
crosshatch, 100% white signal, 20% gray signal, gray
scale, and PLUGE (Picture Line Up Generating
Equipment).
For screen
BKM-33H20 Monitor 16:9 Mask
Adapts the BVM-20F1U/20F1E/20E1U/20E1E screen
for 16:9 aspect ratio display.
• Built-in VITC (Vertical Interval Time Code) reader.
• Built-in Caption Vision.
BKM-33H14 Monitor 16:9 Mask
Adapts the BVM-14F1U/14F1E/14E1U/14E1E/
14F5U/14F5E/14E5U/14E5E screen for 16:9 aspect
ratio display.
• Pulse cross function for simultaneous checking of the
horizontal and vertical synchronization signals. VITS
(Vertical Interval Test Signal) checking is also
possible.
• Auto and manual degaussing.
• Built-in CRT protection circuit.
For installation
• The monitor may be mounted in an EIA-standard 19-
inch rack, using an optional BKM-30E20/30E14/
31E14 Rack Mount Kit.
• Controllable from the optional BKM-10R/11R
Monitor Control Unit. (For details about connection
and operation, refer to the BKM10R/11R Operation
Manual.
BKM-30E20 Rack Mount Kit
Rack mount kit for mounting the BVM-20F1U/20F1E/
20E1U/20E1E in an EIA standard 19-inch rack.
BKM-30E14 Rack Mount Kit
Rack mount kit for mounting the BVM-14F5U/14F5E/
14E5U/14E5E in an EIA standard 19-inch rack.
BKM-31E14 Rack Mount Kit
Rack mount kit for mounting the BVM-14F1U/14F1E/
14E1U/14E1E in an EIA standard 19-inch rack.
Options
For external control
BKM-32H Monitor Control Unit Attachment Kit
Assembly kit for attaching a BKM-10R Monitor
Control Unit to the BVM-20F1U/20F1E/20E1U/
20E1E monitor.
BKM-10R Monitor Control Unit
External control unit for the BVM-20F1U/20F1E/
20E1U/20E1E and BVM-14F1U/14F1E/14E1U/
14E1E.
BKM-11R Monitor Control Unit
A controller for this monitor and other BVM-series
video monitors, allowing you to control multiple
monitors from one control unit.
BKM-12Y Monitor Memory Card
Memory cards which can be read and written by the
BKM-10R/11R or BVM-14F5U/14F5E/14E5U/
14E5E.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
BKM-24N NTSC Decoder Adaptor
Decoder and input expansion adaptors
Includes a decoder for analog composite NTSC signals
and input/output connectors for six analog channels.
The input signal type for each connector is set with the
INPUT CONFIGURATION menu, in accordance with
the configuration of the connector panel.
The input connector panel is configured by sliding
optional decoder adaptors and/or input expansion
adaptors into input option slots at the rear of the
monitor. The BVM-20F1U/20F1E/20E1U/20E1E/
14F5U/14F5E/14E5U/14E5E may be fitted with up to
four adaptors, and the BVM-14F1U/14F1E/14E1U/
14E1E will accept two.
BKM-25P PAL Decoder Adaptor
Includes a decoder for analog composite PAL signals
and input/output connectors for six analog channels.
The input signal type for each connector is set with the
INPUT CONFIGURATION menu, in accordance with
the configuration of the connector panel.
Note
When installing the adaptors, be sure to perform the
necessary input signal setup with the INPUT
CONFIGURATION menu. If the setup is not
performed, the adaptors may not function correctly.
BKM-26M PAL-M Decoder Adaptor
Includes a decoder for analog composite PAL-M
signals and input/output connectors for six analog
channels. The input signal type for each connector is
set with the INPUT CONFIGURATION menu, in
accordance with the configuration of the connector
panel.
For information about the INPUT CONFIGURATION
menu, see “Setting the Input Configuration —INPUT
CONFIGURATION Menu” on page 33.
BKM-20D SDI 4:2:2 Decoder Adaptor
Includes decoders for serial digital component signals
(525/625). Input/output connectors for three serial
digital channels (component inputs only) and three
analog channels. The input signal type for each
connector is set with the INPUT CONFIGURATION
menu, in accordance with the configuration of the
connector panel.
BKM-27T Tri-Standard Decoder Adaptor
Includes decoders for analog composite NTSC, PAL,
and SECAM signals and input/output connectors for
six analog channels. The input signal type for each
connector is set with the INPUT CONFIGURATION
menu, in accordance with the configuration of the
connector panel.
BKM-21D SDI Multi Decoder Adaptor
Includes decoders for serial digital signals (525/625
component and NTSC/PAL composite) and analog
composite signals (NTSC and PAL). Input/output
connectors for three serial digital channels and three
analog channels are equipped. The input signal type
for each connector is set with the INPUT
BKM-28X Analog Input Expansion Adaptor
Used with decoder adaptors, increases the number of
input/output channels. Includes input/output
connectors for six analog channels. The input signal
type for each connector is set with the INPUT
CONFIGURATION menu, in accordance with the
configuration of the connector panel.
CONFIGURATION menu, in accordance with the
configuration of the connector panel.
BKM-48X HD Analog Input Expansion Adaptor
Increases the number of input/output channels.
Includes input/output connectors for six analog
channels. For each input/output connector, either
floating or ground can be selected by the switch inside
the board. The input signal type for each connector is
set with the INPUT CONFIGURATION menu, in
accordance with the configuration of the connector
panel.
BKM-22X SDI Input Expansion Adaptor
Used with decoder adaptors, increases the number of
input/output channels. Includes input/output
connectors for three serial digital channels and three
analog channels. The input signal type for each
connector is set with the INPUT CONFIGURATION
menu, in accordance with the configuration of the
connector panel.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Connector Panel Configuration
The monitor comes standard with connectors for one
channel of Y/R–Y/B–Y or RGB. By adding optional
decoder adaptors and/or input expansion adaptors, the
input/output connector panel can be assembled in a
wide variety of configurations.
The signals that each of the adaptors’ connectors
supports are given in the table below. The type of
signal to be applied to each input/output connector is
set with the INPUT CONFIGURATION menu.
Notes
• Only one BKM-22X board can be installed in the
monitor together with either the BKM-20D or the
BKM-21D.
• The BKM-20D, BKM-21D, and BKM-22X can not
provide proper active-through outputs if a signal
whose format is not selected in the INPUT
CONFIGURATION menu is input. (If AUTO is
selected, input a signal which has the same format
with the signal monitored last.)
For details of the INPUT CONFIGURATION menu, see
“Setting the Input Configuration —INPUT
CONFIGURATION Menu” on page 33.
Adaptor name
BKM-20D BKM-21D BKM-24N BKM-25P
BKM-26M BKM-27T
BKM-22X
SDI Input
Expansion Input
BKM-28X
Analog
BKM-48X1)
HD Analog
Input
SDI 4:2:2
Decoder
Adaptor
SDI Multi
Decoder
Adaptor
NTSC
Decoder
Adaptor
PAL
Decoder
Adaptor
PAL-M
Tri-
Decoder
Adaptor
Standard
Decoder
Adaptor
Adaptor
Expansion Expansion
Adaptor
Adaptor
Serial
digital 525/625
input
Component
O
®
®
®
O
O
O
O
O
®
®
®
®
®
®
®
®
O
O
Composite
NTSC
Composite
PAL
Analog Composite
input
O
®
®
®
O
®
®
®
O
®
O
O
®
®
O
–
O
O
®
O
O
O
O
O
®
–
®
®
®
®
®
®
NTSC
Composite
PAL
®
®
Composite
PAL-M
®
Composite
SECAM
®
®
O
O
O
®
®
–
®
®
O
O
®
®
®
–
®
O
O
®
®
®
–
O
O
Y/R–Y/B–Y
525/625
O
O
O
O
®
RGB 525/
625
Y/C
NTSC
Y/C
PAL
O
®
–
Y/C
PAL-M
Number of digital
inputs
3
3
3
3
3
3
6
6
6
6
6
6
Number of analog
input
®: Input possible when used with decoder adaptor
O: Independent input possible
1) Equipped with floating/non-floating ground mode selector
for hum reduction.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
Decoder adaptor priority
The table on the right shows which decoder adaptor
will be selected preferentially when more than one
decoder adaptor which can accept the NTSC or PAL
signal format have been installed in the monitor.
Decoder adaptor
Input signal type
and format
BKM-
24N
BKM-
25P
BKM-
27T
BKM-
21D
Composite NTSC
1
3
3
2
2
2
2
signal
PAL
1
1
For example, when a BKM-24N and a BKM-27T are
installed and an NTSC signal is selected, the NTSC
signal connected to the BKM-24N’s input connectors
and the NTSC signal connected to the BKM-27T’s
input connectors are both processed by the decoder on
the BKM-24N.
Y/C
signal
NTSC
PAL
1
Numbers in the table show priority.
Note on using the BKM-20D/21D
When installing the input adaptor in an input option
slot on the rear of the monitor, or fitting a cover plate
to an unused slot, always do such operation in order
from the rightmost slot, as shown in Figure 1. If a
BKM-20D/21D is already installed, first of all remove
it and then do the installing operation in order from the
rightmost slot.
When removing a BKM-20D/21D, always loosen all
input adaptor screws and then remove in order from
the rightmost slot, as shown in Figure 2.
Figure 1
Figure 2
When one of the input option slots on the rear of the
monitor has a BKM-20D/21D (optional) installed, if
the slot to the right has another adaptor or the analog
input connectors board, or a cover plate fitted, as
shown in Figure 3, the radiation shield of the BKM-
20D/21D may be damaged or detached (see Figure 4).
Using the BKM-20D/21D with the radiation shield
damaged or detached may result in electromagnetic
interference. Always use care about the radiation
shield.
Radiation shield
Input adaptor
Cover plate
Analog input connectors board
BKM-20D/21D
Input adator, etc.
Input option slots
Figure 3
Figure 4
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Location and Function of Parts
Front Panel
BVM-14F5U/14F5E/14E5U/14E5E
1 Tally lamp
2 POWER switch
0 SHIFT button
3 DEGAUSS button
4 Numeric keypad
!¡ Function buttons
5 MANUAL adjustment
buttons and knobs
!™ Monitor Memory
Card slot
6 Menu operation
buttons
!£ OPTION connector
7 POWER lamp
8 STANDBY lamp
9 OVER LOAD lamp
BVM-20F1U/20F1E/20E1U/20E1E/14F1U/14F1E/14E1U/14E1E
1 Tally lamp
!£ OPTION connector
7 POWER lamp
8 STANDBY lamp
9 OVER LOAD lamp
(Illustration: BVM-20F1U/20F1E/20E1U/20E1E)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Location and Function of Parts
This manual explains the location and function of parts
and controls using the control panel of the BVM-
14F5U/14F5E/14E5U/14E5E. The explanation applies
to BVM-20F1U/20F1E/20E1U/20E1E/14F1U/14F1E/
14E1U/14E1E with the BKM-10R/11R Monitor
Control Unit.
Channel number entry method:
(In the explanation below, x represents any digit
between 1 and 9, and y represents any digit between
0 and 9.)
When selecting a channel number from 1 to 9, press
the x button to display channel x. When selecting a
channel number from 10 to 99, press the 0, x, and y
buttons to display channel xy (a two-digit channel
number).
1 Tally lamp
With factory settings, the Tally lamp lights when pins
No. 8 and No. 9 of the REMOTE 2 connector on the
rear panel are shorted. By changing the setting in the
REMOTE menu, different pins on the remote
connector can be used to control the tally lamp.
5 MANUAL adjustment buttons and knobs
Each press of one of these buttons turns the button’s
green LED on or off. When the corresponding button
is on (lit), it is possible to manually adjust the contrast,
brightness, chroma and phase by turning the
corresponding knobs. They are also used to enter the
setting values with the menus. It is possible to set the
preset value for each adjusting item with the
CONTROL PRESET ADJ menu.
For details of the REMOTE menu, see “Assigning the
Remote Control Functions —REMOTE Menu” on page 38.
2 POWER switch
Press to turn on/off the monitor. By setting with the
ADDRESS menu, it is possible to turn on/off the
power of the specified monitors only, or of all
monitors at the same time.
For details of the CONTROL PRESET ADJ menu, see
“Preset Adjustment of the Picture Level Control Knobs -
CONTROL PRESET ADJ menu” on page 25.
For details of the ADDRESS menu, see “Selecting the
Monitor to Control - ADDRESS Menu” on page 54.
Notes
When using the composite SECAM, composite PAL
D, component or SDI (component or composite serial
digital interface) format, note the following.
• The signal phase cannot be adjusted.
• The phase and chroma of RGB signals cannot be
adjusted.
3 DEGAUSS button
Press to degauss the CRT (every time the monitor is
turned on, the CRT is degaussed automatically). To
degauss again, wait for more than five minutes.
4 Numeric keypad
Use to designate the channel number for the input
signal to be monitored, or to enter the setting values
with the menus.
MANUAL
CONTRAST
CONTRAST button and
knob
INPUT
BRIGHT
1
4
7
3
6
2
5
8
0
BRIGHT button and knob
CHROMA button and knob
Numeric buttons
CHROMA
9
Ent button: Confirms the
values and characters entered
(ENTER button of the menu
operation buttons 6 has the
same function).
Ent
Del
PHASE
PHASE button and knob:
Changes the items and
settings on the menus
Del button: Deletes the values
and characters entered.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
6 Menu operation buttons
MENU button: Press to display the Menus.
UP
MENU
UP/DOWN buttons: Press to select the
items and setting values.
ENTER
DOWN
ENTER button: Press to confirm the items
and values entered (Ent button on the
numeric keypad 4 has the same function).
For details of menu operation, see “Basic Menu
Operations” on page 22.
7 POWER lamp
Lights when the monitor is put into operation mode
from standby mode (see STANDBY lamp 8) by
pressing the POWER switch 2.
Note
When the STANDBY lamp 8 is blinking, the monitor
cannot be put into operation mode (internal data
initialization is taking place). Wait until the
STANDBY lamp 8 is steadily lit.
8 STANDBY lamp
Lights when the monitor is in standby mode. The
monitor will be in standby mode under the following
conditions:
• The MAIN POWER switch (on the rear panel) is
turned on (the STANDBY lamp will blink for a few
moments after the switch is turned on, then will
light).
• The monitor is changed from operation mode to
standby mode by external control.
9 OVER LOAD lamp
Lights to warn of CRT overload.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Location and Function of Parts
0 SHIFT button
Press to select one of the two functions designated to
the function buttons !¡.
Each time the SHIFT button is pressed, the LED turns
on (SHIFT ON: lit in orange) and off (SHIFT OFF: lit
in green).
SHIFT OFF: The functions indicated on the left side
of the function buttons can be used.
!¡ Function buttons
Change the operation conditions for the monitor.
Each time the button is pressed, the LED turns on and
turns off, and the operation conditions are changed.
Each button has two functions. Select one of the two
functions by pressing the SHIFT button 0. When the
SHIFT button is set to ON, the LED lights in orange,
and when the SHIFT button is set to OFF, the LED of
each button lights in green.
SHIFT ON: The functions indicated on the right side
of the function buttons can be used.
SHIFT OFF (LEDs of function buttons in green)
(Underscan) button: When this button is pushed in (ON), the picture is
underscanned by 3%, and four ends of the raster is displayed on the screen.
(H delay) button: When this button is pushed in (ON), the picture moves
horizontally, and a horizontal sync signal appears approximately one quarter in the
left edge of the screen.
• The brightness of the picture increases automatically, and it makes it easy to check
the sync part.
• If it is pressed together with the
button, a pulse cross picture is displayed.
(V delay) button: When this button is pushed in (ON), the picture moves vertically,
and a vertical sync signal appears approximately in the center of the screen.
• The brightness of the picture increases automatically, and it makes it easy to check
the sync part.
• If it is pressed together with
button, a pulse cross picture is displayed.
16 : 9
MONO button: When this button is pushed in (ON), a monochrome picture is displayed.
When the buttons is off, the monitor switches automatically between color and
monochrome mode, depending on the presence or absence of color burst signal.
SYNC
BLUE
ONLY
APT (aperture) button: When this button is pushed in (ON), the frequency response
can be modified. The degree of modification is set with the menu.
This function is available when an optional decoder adaptor such as a BKM-24N is
installed.
R
G
B
MONO
APT
COMB
F1
COMB button: Turn the comb filter on and off.
This function is available when an optional decoder adaptor such as a BKM-24N is
installed.
F3
F4
F1 button: When this button is pushed in (ON), the characters disappear from the
monitor on the MANUAL menu of the level 2 of the CONTROL PRESET ADJ menu,
the MANUAL menu of the level 2 of the COLOR TEMP ADJ menu, and the
ALIGNMENT menu of the level 2 of SETUP menu.
F2
SAFE
AREA
ADDRESS
F2 button: When this button is pushed in (ON), you can access directly the MANUAL
menu of the level 2 of the COLOR TEMP ADJ menu, if the short-cut function is
assigned to this button.
For details of short-cut functions, see “Setting the Channel Selection Method and Power-Up
Conditions – System Configuration Menu” on page 42.
ADDRESS button: When this button is pushed in (ON), the ADDRESS menu appears
on the screen. By using the ADDRESS menu, operation conditions for multiple
monitors are set.
For details of the ADDRESS menu, see “Selecting the Monitor to Control - ADDRESS
Menu” on page 54.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
SHIFT ON (LEDs of function buttons in orange)
16:9 button: When this button is pushed in (ON), the aspect ratio changes to
16:9, and when set to OFF, the aspect ratio changes to 4:3.
SYNC button: When this button is pushed in (ON), the monitor synchronizes
to the sync signal input to the SYNC connectors on the rear panel (EXT
SYNC). When set to OFF, it synchronizes to the sync signal included in
the signals being monitored (INT SYNC).
Notes
• When INT SYNC is selected, use a component or YC signals including a
sync signal on the Y signal, and use RGB signal including a sync signal
on the G signal.
16 : 9
SYNC
• To monitor serial digital signals, select INT SYNC.
BLUE ONLY button: When this button is pushed in (ON), red and green
signals are cut, and only the blue signal is displayed as a monochrome
picture. It makes it easy to adjust CHROMA and to check VTR noise.
BLUE
ONLY
R
G
MONO
R/G/B buttons: When these buttons are pushed in (ON), R(red), G(green),
and B(blue) beams are cut respectively.
APT
COMB
F1
B
F3/F4 buttons: For future expansion.
F3
F4
F2
SAFE
AREA
SAFE AREA button: When this button is pushed in (ON), a safe area is
displayed on the screen.
ADDRESS
Note
When EXT SYNC is selected, the safe area display possibly may not be
shown in the correct position.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Location and Function of Parts
!™ Monitor Memory Card slot
Insert the BKM-12Y Monitor Memory Card
(optional).
Notes
Do not eject the monitor memory card while data is
being saved or loaded.
For details of operations on monitor memory card data, see
“Monitor Memory Card Data Operations — MEMORY
CARD menu” on page 51.
Proceed as illustrated to insert and eject the BKM-12Y
Monitor Memory Card.
To insert the BKM-12Y Monitor Memory Card
Monitor memory card insertion slot
Caution
Push the monitor
memory card in
until the EJECT
button comes out.
Be careful not to let your hands touch the
connectors on the front edge of the
monitor memory card.
EJECT button
Monitor memory card
To eject the BKM-12Y Monitor Memory
the monitor
memory card.
Take out the
monitor memory
card.
Card
EJECT button
Press the EJECT button to eject
!£ OPTION connector
Used to connect the BKM-11R Monitor Control Unit
or BKM-14L Auto Setup Probe.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Rear Panel
6 Analog input/output
connectors
7 Input option slots
8 REMOTE 1 connectors
and TERMINATE
switch
9 REMOTE 2 connector
1 MAIN POWER switch
2 AC IN connector
3 Fuse
!º ISR connector
4 Deflection option slot
5 CONTROL UNIT connector
(not provided on BVM-
14F5U/14F5E/14E5U/
14E5E)
(Illustration: BVM-20F1U/20F1E/20E1U/20E1E)
3 Fuse
1 MAIN POWER switch
Use a T4AH fuse.
When turned on, the monitor enters standby mode. By
a setting in the SYSTEM CONFIGURATION menu,
the monitor can also be set to enter operation mode
when the MAIN POWER switch is turned on.
4 Deflection option slot
Slot for future expansion.
For details of the SYSTEM CONFIGURATION menu, see
“Setting the Channel Selection Method and Power-Up
Conditions —SYSTEM CONFIGURATION Menu” on page
42.
5 CONTROL UNIT connector (female, D-sub 9-
pin)(not provided on BVM-14F5U/14F5E/14E5U/
14E5E)
Connects a monitor control unit such as the BKM-10R
using a straight cable with D-sub 9-pin plugs such as
an RCC-5G (not supplied).
2 AC IN connector (3-pin)
Connects the monitor to an AC power source, via the
supplied AC power cord.
AC power cord (supplied)
Cord stopper (supplied)
Plug holder
Attach the cord stopper to the AC power cord, and connect it
to the plug holder so that the cord does not come loose.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Location and Function of Parts
6 Analog input/output connectors
8 REMOTE 1 connectors (female, D-sub 9-pin),
and TERMINATE switch
ANALOG
REMOTE 1
IN
Y/G
Y/G connectors (BNC)
OUT
IN
REMOTE 1 IN connector
TERMINATE switch
IN
B–Y/B connectors (BNC)
B-Y/B
OUT
TERMINATE
ON
OFF
IN
R-Y/R
R–Y/R connectors (BNC)
OUT
IN
SYNC
OUT
SYNC connectors (BNC)
OUT
REMOTE 1 OUT connector
RGB signals, component signals (Y, R–Y, and B–Y),
or composite sync signals can be fed in the IN
connectors. The type of signal applied to each
connector is set with the INPUT CONFIGURATION
menu. The OUT connectors are used for loop-through
output of the input signal. When not using loop-
through, connect a 75-ohm terminator (not supplied) to
the OUT connectors.
These are RS-485 serial interface connectors, used for
connecting two or more BVM/HDM-series monitors.
The IN and OUT connectors form a loop-through
connection. Set the TERMINATE switch to OFF.
Connect two monitors using a straight cable with D-
sub 9-pin plugs such as an RCC-5G (not supplied) as
shown in the figure.
For details of the INPUT CONFIGURATION menu, see
“Setting the Input Configuration—INPUT
CONFIGURATION menu” on page 33.
Monitor 2
Monitor 1
REMOTE 1
REMOTE 1
IN
IN
7 Input option slots
The BVM-20F1U/20F1E/20E1U/20E1E/14F5U/
14F5E/14E5U/14E5E may be fitted with up to four
adaptors, and the BVM-14F1U/14F1E/14E1U/14E1E
will accept two.
TERMINATE
ON
OFF
TERMINATE
ON
OFF
OUT
OUT
TERMINATE
switch: OFF
TERMINATE
switch: OFF
Straight cable with D-sub 9-pin plugs (not supplied)
16
Download from Www.Somanuals.com. All Manuals Search And Download.
9 REMOTE 2 connector (female, D-sub 9-pin)
Forms a pararell switch and controls the monitor
externally. The pin arrangement and factory setting
function assigned to each pin are given below.
5
1
9
6
Pin number Function
1
Set input signal channel 1 (numeric keypad
function)
2
Set input signal channel 2 (numeric keypad
function)
3
4
Select sync signal (SYNC button function)
Set the screen to monochrome, or set for
automatic switching based on the input signal
(MONO button function)
5
Safe area on/off (SAFE AREA button
function)
6, 7
8
Undefined
Tally lamp on/off
Ground
9
All pin function assignments can be changed with the
REMOTE menu.
For details of the REMOTE menu, see “Assigning the
Remote Control Functions —REMOTE Menu” on page 38.
To switch each function between on and off or
between enable and disable, change pin connections in
the following way.
On or enabled: Short each pin and pin 9 together.
Off or disabled: Leave each pin open.
!º ISR (Interactive Status Reporting) connector
(female, D-sub 9-pin)
Connect to the ISR system.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Structure
The various functions and operating conditions of the
monitor can be set with on-screen menus. Each menu
consists of several levels of subsidiary menus or lists
of settings. An overview of the menu system is shown
in “Menu Directories” on page 21, and the details of
the structure of each menu is shown at the top of the
explanation of the menu.
Displaying Menus
To display menus, press the MENU button.
When you select a menu from the main menu, a list of
items for the selected menu is displayed on the screen.
The display of this list is called “the level 1 display” of
the selected menu.
A list of menus, called “the main menu”, is displayed
on the monitor screen.
The adjustments and settings which can be made with
the respective menus are outlined in the table below.
M E N U
p C O N T R O L P R E S E T A D J...
C O L O R T E M P A D J...
S E T U P...
A
B
C
D
E
F
Note
M E M O R Y C A R D...
C O P Y...
On this monitor, menu settings displayed in blue
cannot be changed.
S T A T U S...
M A I N T E N A N C E...
K E Y P R O T E C T
G
H
O F F
Main menu
Functions
Display of the main menu level
A
B
C
CONTROL PRESET ADJ menu
COLOR TEMP ADJ menu
SET UP menus
Sets the preset values for the input signal contrast, brightness, chroma, and phase.
Sets the color temperature.
A menu group for performing monitor setup, consisting of the following.
• INPUT CONFIGURATION menu: Sets the input channel.
• REMOTE menu: Sets the remote control functionality.
• PASSWORD menu: Sets passwords for menus.
• SYSTEM CONFIGURATION menu: Sets the input channel selection method and
power-up conditions.
• ON SCREEN SET menu: Sets data about the screen display.
• ALIGNMENT menu: Used to adjust the screen convergence and geometry.
• EXTEND MENU:Used to back up the monitor data and re-load the factory data
from the installed board.
D
E
F
MEMORY CARD menu
COPY menu
Operates on data in the memory card.
Copies set-up data from other connected monitors.
Displays the information about the monitor or options installed in the monitor.
Menu for maintenance (typically not used).
STATUS menu
G
H
MAINTENANCE menu
KEY PROTECT
When set to ON, function buttons on the control unit (with the exception of menu
operation buttons) will be disable. When set to OFF, key protection is removed.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Structure
About menu numbers
In this manual, menu numbers are used to classify the
menus and show the route that you follow to reach any
particular menu.
A menu number consists of a letter (alphabetical
character) followed by one or more digits. The letter
identifies the menu group (see the preceding page),
and the digits indicate selections to be made on the
respective menu levels.
For example, the menu number A1321 shows that you
can reach the menu by making selections on the
respective menu levels as follows.
Select CONTROL PRESET ADJ in the
main menu.
Select the 1st item on menu level 1.
Select the 3rd item on menu level 2.
Select the 2nd item on menu level 3.
Select the 1st item on menu level 4.
e.g. A1321
Note
The menu numbers are merely for convenience of
explanation. They do not appear on the screen of your
monitor.
ADDRESS Menu
In addition to the menus listed in the table, the
ADDRESS menu is provided. This ADDRESS menu
is used to select the monitor or the monitor group, so
that when several monitors are connected together via
serial remote ports, the control panel can select which
monitor to control.
To display or exit the ADDRESS menu, press the
ADDRESS button. The method of choosing menu
items and changing settings is the same as with the
other menus.
For details of the ADDRESS menu, see “Selecting the
Monitor to Control —ADDRESS Menu” on page 54.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Directories
The menu system for the BVM-series monitors
covered by this manual is largely divided into eight
menus (or eight menu groups), which are arranged in
the main menu. Each of the eight menus consists of
many items (subsidiary menus and settings) arranged
on several menu levels.
The diagram below shows part of the structure of the
menu system from the main menu down to level 2. For
the structure of each menu, see the page whose number
is shown in ( ).
Main menu
Level 1
Level 2
MANUAL A11
AUTO A 12
COPY A 13
CONTROL PRESET ADJ A
(page 25)
PRESET
CH SET
A1
B1
MANUAL B11
PROBE B12
COPY B13
TRIM B14
COLOR TEMP ADJ B
(page 27)
STD
COL1
COL2
CH SET
FORMAT C11
SLOT NO
SET UP C
INPUT CONFIGURATION C1
(page 33)
REMOTE1 CONFIG C21
REMOTE2 CONFIG C22
REMOTE C2
(page 38)
ENTER PASSWORD C31
PASSWORD C3
(page 40)
INPUT SELECT
STANDBY MODE
DEFAULT CH
SYSTEM CONFIGURATION C4
(page 42)
VITC C51
ON SCREEN SET C5
(page 44)
CAPTION VISION C52
ANCILLARY DATA
ROTATION (1/4)
H PIN (2/4)
ALIGNMENT C6
(page 46)
V STATIC CONV (3/4)
H CV RC (4/4)
ENTER PASSWORD C71
NEW NAME
EXTEND MENU C7
(page 48)
MEMORY CARD D
SAVE D1
(page 51)
LOAD D2
DELETE D3
FORMAT D4
ALL
COPY E
MONITOR ADDRESS E1
(page 52)
CONTROL PRESET
COLOR TEMP
SET UP
CH STATUS F11
MODEL NAME
SLOT F31
STATUS F
(page 53)
STATUS (1/3) F1
STATUS (2/3) F2
STATUS (3/3) F3
MAINTENANCE G
KEY PROTECT H
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Basic Menu Operations
Menu Operation Buttons
Menu Operation
The menus are operated using the menu operation
buttons on the front panel.
This section describes how to display the desired menu
(or reach the desired menu level) and how to make
adjustments and settings you wish.
INPUT
1
4
7
3
6
2
5
8
0
To display the desired menu, proceed as follows.
1 Numeric keypad
1 Press the MENU button 5.
The main menu is displayed.
9
2 Using the UP and DOWN buttons 6 or PHASE
knob 4, move the cursor to the desired item.
(Example: select the SET UP menu by pressing the
DOWN button.)
Ent
2 Ent button
Del
3 Del button
PHASE
M E N U
C O N T R O L P R E S E T A D J...
C O L O R T E M P A D J...
p S E T U P...
4 PHASE knob
5 MENU button
M E M O R Y C A R D...
UP
MENU
ENTER
C O P Y...
S T A T U S...
M A I N T E N A N C E...
6 UP and DOWN buttons
DOWN
K E Y P R O T E C T
O F F
Cursor
7 ENTER button
Main menu
The functions of the menu operation buttons are
described below.
3 Press the ENTER button 7.
The level 1 display of the selected menu appears.
Button
Function
5MENU button
Displays the main menu or brings you
back to an upper menu level. (When
on the main menu, switches back to
the normal picture display.)
S E T U P
p I N P U T C O N F I G U R A T I O N...
R E M O T E...
P A S S W O R D...
6UP button
Moves the cursor upward. In setting
mode, increases the setting and
adjustment values.
S Y S T E M C O N F I G U R A T I O N...
O N S C R E E N S E T...
A L I G N M E N T...
6DOWN button
4PHASE knob
Moves the cursor downward. In setting
mode, decreases the setting and
adjustment values.
E X T E N D M E N U
...
By turning this knob clockwise, the
cursor moves upward. In setting mode,
increases the setting and adjustment
values (same function as UP button).
By turning this knob counterclockwise,
the cursor moves downward. In setting
mode, decreases the setting and
adjustment values (same function as
DOWN button).
2Ent button
7ENTER button
Confirms the current selection of
menu item/setting.
3Del button
Deletes the values and characters
entered.
1Numeric keypad Enters numerical values.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
4 Repeat steps 2 and 3 until the desired menu is
2 Using the UP and DOWN buttons or PHASE
displayed.
knob, change the setting.
On how to make adjustments and settings on the menu
thus displayed, see the following descriptions.
3 Press the ENTER or Ent button.
The setting is confirmed (the item is displayed in
white text again).
[ ↓ ] indicates that
the menu
continues onto
next page.
[ ↑ ] indicates that
the menu is
continued from
previous page.
I N P U T C O N F I G U R A T I O N ↑↓
Selecting from a setting list
0 1 C H
F O R M A T...
S L O T N O
N T S C - 7 .5
p
2
1
Using the UP and DOWN buttons or PHASE knob,
move the cursor to the desired item in the setting list.
I N P U T N O
Y C S E P
1
3 L I N E S C O M B
I N T
Select from
various options.
S C R E E N M O D E
S Y N C
M O D E
Indicates that
selecting this
item brings you
to a lower menu
level.
S C R E E N M O D E...
4 : 3 - N O R M
O F F
S A F E
A R E A
4 : 3 - N O R M
p
S C A L E...
8 0 %
4 : 3 - U N D R
1 6 : 9 - N O R M
1 6 : 9 - U N D R
A P E R T U R E
V A L U E
O F F
1 0 0
Enter numerical
values.
To abort menu operation
Press the MENU button. The screen display switches
back to that of the upper menu level, or to the normal
picture display.
The setting or adjustment being performed is canceled,
and data loading or saving is aborted.
2 Press the ENTER button.
The setting is confirmed, and the screen display
returns to that of the upper menu level.
If“NG”or“ERROR”appearsduringmenuoperation
Press the MENU button. This brings you back to the
initial display of the current menu.
Entering a numerical value
1 Using the UP and DOWN buttons or PHASE
knob, move the cursor to the desired item and press
the ENTER or Ent button.
Choosing one of two or more selections
Selecting in yellow text
The selected item is displayed in yellow text,
which indicates that the monitor is now in setting
mode for that item.
1 Using the UP and DOWN buttons or PHASE knob,
move the cursor to the desired item and press the
ENTER or Ent button.
I N P U T C O N F I G U R A T I O N ↑↓
0 1 C H
The selected item is displayed in yellow text,
which indicates that the monitor is now in setting
mode for that item.
F O R M A T...
S L O T N O
N T S C - 7 .5
2
I N P U T N O
Y C S E P
1
3 L I N E S C O M B
I N T
I N P U T C O N F I G U R A T I O N ↑↓
S Y N C
S C R E E N M O D E...
S A F E A R E A
S C A L ...
M O D E
0 1 C H
4 : 3 - N O R M
O F F
F O R M A T...
S L O T N O
N T S C - 7 .5
2
E
8 0 %
I N P U T N O
Y C S E P
1
3 L I N E S C O M B
I N T
A P E R T U R E
V A L U E
O F F
0 8 5
p
S Y N C
M O D E
p
S C R E E N M O D E...
4 : 3 - N O R M
O F F
(Continued)
S A F E
A R E A
S C A L E...
8 0 %
A P E R T U R E
V A L U E
O F F
1 0 0
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Basic Menu Operations
2 Set the value in one of the following three ways:
• Enter the value using the numeric keypad
• Select the value using the UP and DOWN buttons
• Select the value using the PHASE knob
3 Select the character you wish to enter using the UP
and DOWN buttons or PHASE knob. When you
press the UP button, or turn the PHASE knob
clockwise, characters and symbols appear one by
one in the order shown below.
3 Press the ENTER button.
The setting is confirmed (the item is displayed in
white text again).
A, B, .............Y, Z, 0, 1, ...............8, 9, ( , ), :, ;, .,
-, +, /, &, CH, (space), ?
If you press the DOWN button or turn the PHASE
knob counterclockwise, the characters and symbols
appear in the reverse order.
Entering characters
1 Display the setting menu and set the cursor to
NEW NAME using the UP and DOWN buttons or
PHASE knob.
4 Press the ENTER button.
The selected character is entered.
C H A N N E L N A M E
C H A N N E L N A M E
P R O G
E D I T
C A M
P R O G
E D I T
C A M
V T R
V T R
N E W N A M E
p
N E W N A M E
p
C ?
2 Press the ENTER button.
5 Repeat steps 3 and 4 until all the desired characters
are entered, then press the ENTER button.
The entered characters are confirmed, and the
screen display returns to that of the upper menu
level.
“?” is displayed in yellow. The “?” indicates the
position where character input is possible.
C H A N N E L N A M E
P R O G
E D I T
C A M
To correct the entered character
Press the Del button on the numeric keypad. The
character on the left side of the “?” (in yellow) is
deleted. Now you can enter the correct character.
V T R
N E W N A M E
p
?
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Preset Adjustment of the Picture Level Control
Knobs — CONTROL PRESET ADJ Menu
Overview
The preliminary adjustment of contrast, brightness,
chroma, and phase are carried out with the CONTROL
PRESET ADJ menu to set the preset values to the
knobs for the above-mentioned adjustments. Preset
values can be set either commonly to all channels or
separately for individual channels.
(1) Adjustment with the MANUAL knobs
(2) Automatic adjustment (An external color bar signal
is necessary.)
(3) Copying data from other channels, common data,
other BVM-series monitors that have been
connected via the serial remote connector, or from
data stored in monitor memory cards
Preset values can be set in the following ways:
(4) Restoring factory settings.
Structure of the CONTROL PRESET ADJ Menu [A]
Level 1
Level 2
Level 3
Level 4
Level 5
PRESET
CH SET
A1
PHASE
MANUAL A11
CHROMA
BRIGHT
CONTRAST
FULL FIELD CB100
FF CB 75 (WHITE 100)
SMPTE CB
AUTO A12
COPY A13
EIA CB
OTHER VALUE A131
PRESET
CH SET
OTHER MONITOR A132
PRESET
CH SET
MONITOR ADDRESS A1321
MEMORY CARD A133
PRESET
CH SET
FILE NAME A1331
Constituent Menus of the CONTROL PRESET ADJ Menu
This section describes the functions of the constituent
menus of the CONTROL PRESET ADJ menu.
[A] CONTROL PRESET ADJ menu
Select either PRESET or CH SET. ÷ [A1]
PRESET...: Set common values.
Notes
CH SET...: Set values for each individual channel.
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
[A1] PRESET/CH SET menu
Select the setting method.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
MANUAL...: Set with the MANUAL knobs. ÷
[A11]
AUTO...: Set by automatic adjustment. ÷ [A12]
COPY...: Copy data from elsewhere. ÷ [A13]
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Preset Adjustment of the Picture Level Control Knobs — CONTROL
PRESET ADJ Menu
[A11] MANUAL menu
CH SET: Copy data set for another channel. Input
the number of the channel from which the data
will be copied.
Adjust values by turning the PHASE, CHROMA,
BRIGHT, and/or CONTRAST knobs. After the
adjustment, press the ENTER button to confirm the
adjusted values.
PHASE: xxxx
CHROMA: xxxx
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
MENU button.)
BRIGHT: xxxx
CONTRAST: xxxx
When you want to erase characters from the
screen while adjusting manually
Press the [F1] button. The characters disappear. To
display the characters again, press the [F1] button
again.
[A132] OTHER MONITOR menu
Input the address of the monitor from which the data
will be copied. ÷ [A1321]
MONITOR ADDRESS: Input the address.
To reset the setting to the default
Press the corresponding MANUAL button. The
adjusted value is reset to 1000 (default).
[A1321] MONITOR ADDRESS menu
Choose either PRESET or CH SET. ÷ Copy is
carried out.
PRESET: Copy common data.
[A12] AUTO menu
CH SET: Copy data set for another channel. Input
the number of the channel from which the data
will be copied.
Select the color bar signal to be used for automatic
adjustment. ÷ Adjustment is carried out.
FULL FIELD CB 100: 100% full-field color bar
FF CB 75 (WHITE 100): 75% full-field color bar
(with 100% white signal)
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
MENU button.)
SMPTE CB: SMPTE standard color bar
EIA CB: EIA standard color bar
Note
When you execute the AUTO menu, SYNC button
should be set to OFF (INT SYNC). EXT SYNC will
cause an error abortion of auto adjustment procedure.
[A133] MEMORY CARD menu
Select the file name. ÷ [A1331]
FILE NAME: Select the file name.
[A13] COPY menu
Select the source to be copied from.
OTHER VALUE...: Copy data from another channel
or from PRESET setting. ÷ [A131]
OTHER MONITOR...: Copy data from another
monitor. ÷ [A132]
[A1331] FILE NAME menu
Choose either PRESET or CH SET.÷ Copy is
carried out.
PRESET: Copy common data.
CH SET: Copy data set for another channel. Input
the number of the channel from which the data
will be copied.
MEMORY CARD...: Copy data from a memory
card. ÷ [A133]
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
MENU button.)
[A131] OTHER VALUE menu
Choose either PRESET or CH SET. ÷ Copy is
carried out.
PRESET: Copy common data.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting the Color Temperature — COLOR TEMP
ADJ Menu
Overview
The color temperature is adjusted with the COLOR
TEMP ADJ menu. The color temperature can be set
either commonly to all channels or individually for
each channel.
The adjusted value can then be used as an original
value.
(3) Copying other data
Copying data from other channels, common data, other
BVM-series monitors that have been connected via the
serial remote connector, or from data stored in monitor
memory cards.
Color temperature adjustment can be made in the
following three ways:
(1) Knob adjustment
Adjust the color temperature with the bias and gain
knobs.
(2) Automatic adjustment using a probe
You can use the following probes for automatic
adjustment of color temperature. Except for the Sony
BKM-14L, a cable is required to connect the probe to
the monitor.
Manufacturer
SONY
Probe Model Name
BKM-14L (no cable required)
CA-100
MINOLTA
GRASEBY
PHILIPS
SLS 9400
PM 5639
THOMA
TF6
For details of the required cables, see page 60.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
Structure of the COLOR TEMP ADJ Menu [B]
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
ADJUST
MANUAL B11
STD B1
COL1
ORIGINAL VALUE
SIGNAL
INT
COL2
EXT
CH SET
PROBE B12
COPY B13
TRIM B14
START B12111
ADJUST B1211
ANALYZE B1212
SONY BKM-14L B121
SET PROBE
ON CRT
X
Y
GRASEBY SLS9400
MINOLTA CA-100
LOW LIGHT (20IRE)
HIGHLIGHT (100IRE)
PHILIPS RM5639
START
D65
D93
THOMA TF6 B122
X
Y
SET PROBE
ON THIS CRT B12121
LOW LIGHT
(20IRE)
X
Y
L
SET PROBE
ON CRT
HIGHLIGHT
(100IRE)
D65
D93
OTHER VALUE B131
STD
COL1
COL2
CH SET
D65
D93
STD
MONITOR
ADDRESS B1321
OTHER MONITOR B132
MEMORY CARD B133
COL1
COL2
CH SET
STD
FILE NAME B1331
COL1
COL2
CH SET
ADJUST
TRIM
SIGNAL
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Constituent Menus of the COLOR TEMP ADJ Menu
This section describes the functions of the constituent
menus of the COLOR TEMP ADJ menu.
[B11] MANUAL menu
Set the following data necessary to perform knob
adjustment and select ADJUST.
Notes
ADJUST...: Adjust the gain and bias. To shift
between gain adjustment and bias adjustment,
press the UP or DOWN button. Use the
appropriate knob for each adjustment as described
below. After the adjustment, press the ENTER
button to confirm the adjusted values.
RED: CONTRAST knob (Adjust the R gain or
bias with the CONTRAST knob.)
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
GREEN: BRIGHT knob (Adjust the G gain or
bias with the BRIGHT knob.)
BLUE: CHROMA knob (Adjust the B gain or
bias with the CHROMA knob.)
[B] COLOR TEMP ADJ menu
LUMINANCE: PHASE knob (Adjust luminance
with the PHASE knob.)
Select STD, COL1, COL2, or CH SET. ÷ [B1]
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D93).
COL2: Use common data (factory setting: D56/
D651)).
CH SET: Use data for each individual channel
(factory setting: D65). Use the numeric keypad to
select the desired channel.
To reset RED/GREEN/BLUE to the value
before adjustment
When you are adjusting the gain or bias using the
MANUAL adjustment knobs, you can reset the
setting to the one before adjustment by pressing the
corresponding MANUAL button.
To reset all the settings at the same time, press the
PHASE button.
[B1] STD/COL1/COL2/CH SET menu
Select the adjustment method.
Note
MANUAL...: Set with the MANUAL knob. ÷
[B11]
You cannot reset the setting after you press the
ENTER button.
PROBE...: Set using a probe. ÷ [B12]
COPY...: Copy data from elsewhere. ÷ [B13]
TRIM...: Perform fine adjustments after setting the
color temperature. ÷ [B14]
ORIGINAL VALUE...: Set the initial value.
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D93).
COL2: Use common data (factory setting: D56/
D651)).
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100 IRE
and 20 IRE signals are automatically switched.
EXT: Use an external input signal. When
adjusting the gain and bias, input the proper
signal.
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
To access the MANUAL menu directly
When the [F2] button is assigned as the short-cut
key to the MANUAL menu, you can directly
access the MANUAL menu that corresponds to the
color temperature setting set to the image on the
screen.
START: Start adjustment. ÷ [B12111]
X: Enter the x coordinate.
Y: Enter the y coordinate.
LOW LIGHT (20IRE): Enter the brightness (cd/m2)
for low light.
HIGH LIGHT (100IRE): Enter the brightness (cd/
m2) for high light.
For details of how to assign the short-cut key, see
“Setting the Power-Up Conditions - SYSTEM
CONFIGURATION Menu” on page 42.
D65: Use D65 setting.
D93: Use D93 setting.
[B12111] START menu
[B12] PROBE menu
The following message appears. Perform operation
according to the message to start adjustment.
SET PROBE ON CRT
PRESS ENTER
Adjustment starts when the probe is placed against the
center of the screen and the ENTER button is pressed.
Select the probe for color temperature adjustment.
SONY BKM-14L...: Use the BKM-14L. ÷ [B121]
GRASEBY SLS 9400...: Use the SLS 9400. ÷
[B122]
MINOLTA CA-100...: Use the CA-100. ÷ [B122]
PHILIPS PM 5639...: Use the PM 5639. ÷ [B122]
THOMA TF6...: Use the TF6. ÷ [B122]
• If you cannot execute an ADJUST or ANALYZE
menu operation when using the Sony BKM-14L
probe, try again after disconnecting and
reconnecting the probe.
[B1212] ANALYZE menu
The following message appears. Perform operation
according to the message to enable the BKM-14L to
read the color system and luminance value.
SET PROBE ON THIS CRT
PRESS ENTER
Attach the BKM-14L to the center of the monitor
screen and press Enter. ÷ [B12121]
• When using the Thoma TF6 probe, set the TF6
PRINT menu to off.
[B121] SONY BKM-14L menu
Select the BKM-14L operation.
ADJUST...: Perform automatic color temperature
adjustment. ÷ [B1211]
Once the calibration has been carried out, you can use
the probe to analyze the monitor’s performance.
[B12121] ANALYZE menu
ANALYZE: Display readout values on the screen.
Display color temperature and luminance readout
values from the BKM-14L at the bottom of the screen.
X: xxxx: Display the color temperature x coordinate
value.
Y: xxxx: Display the color temperature y coordinate
value.
÷ [B1212]
[B1211] ADJUST menu
To start adjustment, proceed as follows.
When you use the previously adjusted values for
adjustment, you can make start adjustment by selecting
START without perform operations step (1) and step
(2).
L: xxxx: Display the luminance value.
[B122] GRASEBY/MINOLTA/PHILIPS/THOMA
menu
The contents and function of this menu are the same as
those of the ADJUST menu [B1211] .
(1) Select either D65 or D93.
Rather than selecting D65 or D93, you may instead
enter the values of the CIE 1931 color system x
and y coordinates.
(2) Enter values for LOWLIGHT and HIGHLIGHT.
(3) Select START.
[B13] COPY menu
Select the source to be copied from.
OTHER VALUE...: Copy data from another channel
or from common data. ÷ [B131]
OTHER MONITOR...: Copy data from another
monitor. ÷ [B132]
MEMORY CARD...: Copy data from a memory
card. ÷ [B133]
30
Download from Www.Somanuals.com. All Manuals Search And Download.
[B131] OTHER VALUE menu:
[B133] MEMORY CARD menu
Select one of the following. ÷ Copy is carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/
D651)).
Select the file name. ÷ [B1331]
[B1331] FILE NAME menu
Select STD, COL1, COL2,or CH SET of the memory
card data. ÷ Copy is carried out.
CH SET: Copy data from a particular channel
(factory setting: D65). Enter the number of the
channel from which the data will be copied.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
MENU button.)
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/
D651)).
CH SET: Copy data from a particular channel
(factory setting: D65). Enter the number of the
channel from which the data will be copied.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP and DOWN buttons or
PHASE knob is possible without pressing the
MENU button.)
D65: Copy the color temperature of D65.
D93: Copy the color temperature of D93.
[B132] OTHER MONITOR menu
Input the address of the monitor from which the data
will be copied.
[B14] TRIM menu
MONITOR ADDRESS: Input the address of the
monitor from which the data will be copied. ÷
[B1321]
Trim the original setting by selecting ADJUST.
ADJUST: Adjust the gain and bias. To shift between
gain adjustment and bias adjustment, press UP/
DOWN buttons. Use appropriate knobs in each
adjustment as described below. After the
adjustment, press the ENTER button to confirm
the adjusted values.
[B1321] MONITOR ADDRESS menu
Select STD, COL1,COL2, or CH SET. ÷ Copy is
carried out.
STD: Copy common data (factory setting: D65).
COL1: Copy common data (factory setting: D93).
COL2: Copy common data (factory setting: D56/
D651)).
RED: CONTRAST knob (Adjust the R gain or
bias with the CONTRAST knob.)
GREEN: BRIGHT knob (Adjust the G gain or
bias with the BRIGHT knob.)
CH SET: Copy data from a particular channel
(factory setting: D65). Enter the number of the
channel from which the data will be copied.When
the input channel number is deleted with the Del
button. the number “1” appears instead. Restore
the previous setting by pressing the MENU
button, then re-enter the channel number. (Setting
with the UP and DOWN buttons or PHASE knob
is possible without pressing the MENU button.)
BLUE: CHROMA knob (Adjust the B gain or
bias with the CHROMA knob.)
LUMINANCE: PHASE knob (Adjust luminance
with the PHASE knob.)
To reset RED/GREEN/BLUE to the value
before adjustment
When you are adjusting the gain or bias using the
MANUAL adjustment knobs, you can reset the
setting to the one before adjustment by pressing
the corresponding MANUAL button.
To reset all of settings at the same time, press the
PHASE button.
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
TRIM: Select whether to add the fine adjustment to
the original setting (gain and bias set in
MANUAL menu [B1]).
APPLY: Adds the fine adjustment to the original
setting.
When APPLY is selected, “XX/TRIM”
(XX: the selected color temperature among
STD, COL1 or COL2) appears on the left
top on the COLOR TEMP ADJ menu.
NOT APPLY: Reset the setting to the original
setting (gain and bias set in MANUAL
menu [B1]).
SIGNAL: Select the white signal to be used for
adjustment.
INT: Use an internal signal. Simultaneously with
the adjustment of the gain and bias, the 100
IRE and 20 IRE signals are automatically
switched.
EXT: Use an external input signal. When
adjusting the gain and bias, input the proper
signal.
Note
Even if NOT APPLY of the TRIM item is selected,
pressing the ENTER button to confirm the adjusted
values results in that APPLY will be selected.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Input Configuration — INPUT
CONFIGURATION Menu
Overview
Data pertaining to the input signals are set with the
Assigning the Signal Type and Format
INPUT CONFIGURATION menu.
When a channel number (1 to 90) is entered with the
numeric keypad, it is then possible to set which input
connector on the rear panel will be assigned to that
channel number, and select the type of signal that will
be connected. The channel numbers from 91 to 99 are
assigned to internal signals.
091: PLUGE signal (Picture Line Up Generating
Equipment)
092: 20% gray signal
The signal type and format which can be assigned to
each channel number vary, depending on what
adaptors are installed in the rear panel.
Assigning serial digital signals
It is possible to assign serial digital signals to the serial
digital input connectors on the BKM-20D/21D/22X
adaptors. However, at least one BKM-21D which
includes the decoder for serial digital signals or BKM-
20D which includes the decoder for serial digital
component signals must be installed.
093: 100% white signal
094: five-step gray scale signal
095: cross hatch signal
096: cross hatch signal
097: dot signal
098: cross hatch signal
099: 0% black signal
Assigning analog composite signals
It is possible to assign any composite signal to the
analog signal input connectors of the BKM-20D/21D/
22X, and any of the connectors of the BKM-24N/25P/
26M/27T/28X/48X adaptors. However, at least one of
the following decoder adaptors must be installed:
To assign NTSC signals: BKM-21D/24N/27T
To assign PAL signals: BKM-21D/25P/27T
To assign PAL-M signals: BKM-26M
Assigning Slot and Connector Numbers
Set which input connector on which slot will be
assigned to the current channel. The slots are
numbered from the left, as seen when facing the rear
panel, with the REMOTE connectors slot being
number 1, the input option slots numbers 2 to 5, and
the analog input connectors slot being number 6. The
connectors are numbered 1 to 6 (from the top) for the
slot.
To assign SECAM signals: BKM-27T
Assigning Y/C signals
It is possible to assign any Y/C signals to the input
connectors of the BKM-24N/25P/26M/27T/28X/48X
adaptors. However, at least one of the following
decoder adaptors must be installed:
To assign NTSC signals: BKM-24N/27T
To assign PAL signals: BKM-25P/27T
To assign PAL-M signals: BKM-26M
Assigning analog component or RGB signals
Analog component and RGB signals can be assigned
to any input connectors except the serial digital signal
input connectors on the BKM-20D/21D/22X.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Input Configuration — INPUT CONFIGURATION Menu
Structure of the SET UP Menu [C] / INPUT CONFIGURATION Menu [C1]
Level 1
Level 2
Level 3
Level 4
Level 5
INPUT CONFIGURATION C1 (1/2)
xxCH
COMPOSITE C111
YC C111
AUTO
NTSC
PAL
FORMAT C11
SLOT NO
INPUT NO
COMPONENT C112
SDI C113
PAL-M
SECAM
TRAP/BPF
YC SEP C12
2 LINES COMB
3 LINES COMB
YUV
SMPTE/
EBU-N10
YUV
INT
SYNC MODE
BETACAM
EXT
RGB
4:3-NORM
4:3-UNDR
16:9-NORM
16:9-UNDR
SCREEN MODE C13
AUTO
NTSC
PAL
4:2:2
SAFE AREA
SCALE C14
80
90
100
16:9-80
16:9-90
16:9-100
4:3-80
4:3-90
4:3-100
APERTURE
VALUE
INPUT CONFIGURATION C1 (2/2)
xxCH
FILTER
CHANNEL NAME C15
PROG
EDIT
CAM
VTR
NEW NAME
CONTROL
PRESET
CH SET
COLOR TEMP C16
STD
COL1
COL2
CH SET
H PHASE
SAD H POSITION
COPY C17
OTHER CH
REMOTE C2
MONITOR
OTHER MONITOR C171
MEMORY CARD C172
CH NO
CH NO
ADDRESS C1711
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
FILE
NAME C1721
EXTEND MENU C7
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Constituent Menus of the SET UP / INPUT CONFIGURATION Menu
This section describes the functions of the constituent
menus of the SET UP/INPUT CONFIGURATION
menu.
[C1](2/2) INPUT CONFIGURATION menu (2/2)
Set input signal data for each channel.
xxCH: Current channel is indicated. Enter a channel
number with the numeric keypad if changing the
channel. The settings below will be stored as
information about the signal to be connected to
this channel.
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
FILTER: Switch the filter operation (OFF or ON)
when the monochrome display is selected.
CHANNEL NAME...: Give the channel a name. ÷
[C15]
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
CONTROL: Select whether to use local (“CH SET”)
or common (“PRESET”) values for contrast,
brightness, chroma, and phase.
PRESET: Use common data.
CH SET: Use values set for each channel.
COLOR TEMP...: Set the color temperature. ÷
[C16]
[C1](1/2) INPUT CONFIGURATION menu (1/2)
Set input signal data for each channel.
xxCH: Current channel is indicated. Enter a channel
number with the numeric keypad if changing the
channel. The settings below will be stored as
information about the signal to be connected to
this channel.
H PHASE: Set the horizontal picture position (–128
to +127).1)
SAD H POSITION: Adjust the horizontal display
position of the safety area (–128 to +127). 1)
COPY...: Select a method for copying data from
elsewhere. ÷ [C17]
FORMAT...: Select the input signal type. ÷ [C11]
SLOT NO: Enter the slot number.
INPUT NO: Enter the input connector number.
YC SEP...: Select a Y/C separation filter. ÷ [C12]
SYNC MODE: Select the sync signal.
INT: Use an internal sync signal.
1) The monitor will not operate correctly if values above or
below the allowable range are entered.
[C11] FORMAT menu
Select the signal format.
EXT: Use an external sync signal.
COMPOSITE...: Composite signal. ÷ [C111]
YC...: Y/C signal. ÷ [C111]
COMPONENT...: Component or RGB signal. ÷
[C112]
SCREEN MODE...: Select the scan size. ÷ [C13]
SAFE AREA: Choose whether or not to display the
safe area (OFF or ON).
SCALE...: Select the safe area size. ÷ [C14]
APERTURE: Choose whether or not to use aperture
adjustment (OFF or ON).
SDI...: Serial digital signal. ÷ [C113]
Note
VALUE: Enter the aperture adjustment value (0 to
200).
If there is no input connector or decoder corresponding
to a format, that format will not be selectable (the
cursor will skip over that item).
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Input Configuration — INPUT CONFIGURATION Menu
[C111] COMPOSITE menu
[C12] YC SEP menu
Select the format of a composite or Y/C signal.
AUTO: The format of the input signal is detected and
switched automatically.
Select a Y/C separation filter.
TRAP/BPF: Select TRAP/BPF filter.
2 LINES COMB: Select 2 LINES COMB filter.
3 LINES COMB: Select 3 LINES COMB filter.
It will take a few seconds to detect the format of
an input signal when AUTO is selected. It is
recommended that a particular format be selected
if it is determined.
[C13] SCREEN MODE menu
Select the scan size.
4:3-NORM: Overscanned 4:3 aspect ratio.
4:3-UNDR: Underscanned 4:3 aspect ratio.
16:9-NORM: Overscanned 16:9 aspect ratio.
16:9-UNDR: Underscanned 16:9 aspect ratio.
NTSC: SETUP 7.5 or 0.
PAL: S (simple) or D (delay).
PAL-M: S (simple) or D (delay).
SECAM
Notes
[C14] SCALE menu
Select the setting for each items of SAFE AREA
setting list.
• Even when selecting AUTO, also select the NTSC,
PAL, or PAL-M format.
• If there is no input connector or decoder
corresponding to a format, that format will not be
selectable (the cursor will skip over that entry).
• When the BKM-21D is attached, changing the signal
format of a channel from SDI to COMPOSITE
AUTO may prevent proper display of the picture. In
this case, set the format to NTSC or PAL first, then
change to AUTO.
• When inputting the PAL-M YC signal to a channel
with the BKM-26M attached, setting the signal
format to YC AUTO may prevent proper display of
the picture. Set the format to PAL-M (S or D).
80: Displays a 80% safe area in 4:3 screen.
90: Displays a 90% safe area in 4:3 screen.
100: Displays an 100% safe area in 4:3 screen.
16:9-80: Displays a 80% of 16:9 aspect ratio safe
area in 4:3 screen.
16:9-90: Displays a 90% s16:9 aspect ratio safe area
in 4:3 screen.
16:9-100: Displays an 100% 16:9 aspect ratio safe
area in 4:3 screen.
4:3-80: Displays a 80% 4:3 aspect ratio safe area in
16:9 screen.
4:3-90: Displays a 90% 4:3 aspect ratio safe area in
16:9 screen.
4:3-100: Displays an 100% 4:3 aspect ratio safe area
in 16:9 screen.
[C112] COMPONENT menu
Select the component signal format, or RGB.
YUV SMPTE/EBU-N10
YUV BETACAM: SETUP 7.5 or 0
RGB
[C15] CHANNEL NAME menu
Give the channel a name. Select a preset name, or
enter a new one.
PROG: Program signal.
EDIT: Signal from an editor.
CAM: Camera signal.
VTR: Signal from a VTR.
NEW NAME: Enter a new name. (Up to 20
characters can be entered and up to six characters
from the head of the name are displayed in the
INPUT CONFIGURATION menu ([C1], 2/2).)
[C113] SDI menu
Select the format of the serial digital signal.
AUTO: The format of the input signal is detected and
switched automatically.
• It will take a few seconds to detect the format of
an input signal when AUTO is selected. It is
recommended that a particular format be
selected if it is determined.
• If the serial digital signal is not properly displayed at
SDI AUTO mode, re-enter the channel number.
NTSC: SETUP 7.5 or 0
PAL: S (simpe) or D (delay)
4:2:2
36
Download from Www.Somanuals.com. All Manuals Search And Download.
[C16] COLOR TEMP menu
[C1721] MEMORY CARD menu
Select STD, COL1, COL2, or CH SET.
STD: Use common data (factory setting: D65).
COL1: Use common data (factory setting: D93).
COL2: Use common data (factory setting: D56/
D651)).
Select which channel of the chosen file from which to
copy data. ÷ Copy is carried out.
CH NO: Enter the channel number.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP/DOWN buttons or PHASE
knob is possible without pressing the MENU
button.)
CH SET: Use data for the current channel (factory
setting: D65).
[C17] COPY menu
Select the source to be copied from.
OTHER CH: Copy data from another channel.
Enter the channel number.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP/DOWN buttons or PHASE
knob is possible without pressing the MENU
button.)
OTHER MONITOR...: Copy data from another
monitor. ÷ [C171]
MEMORY CARD...: Copy data from a memory
card. ÷ [C172]
[C171] OTHER MONITOR menu
Enter the address of the monitor from which to copy
data.
MONITOR ADDRESS: Enter the address of the
monitor from which to copy data. ÷ [C1711]
[C1711] MONITOR ADDRESS menu
Select which channel of the chosen monitor from
which to copy data. ÷ Copy is carried out.
CH NO: Enter the channel number.
When the input channel number is deleted with
the Del button. the number “1” appears instead.
Restore the previous setting by pressing the
MENU button, then re-enter the channel number.
(Setting with the UP/DOWN buttons or PHASE
knob is possible without pressing the MENU
button.)
[C172] MEMORY CARD menu
Select the file name. ÷ [C1721]
...........................................................................................................................................................................................................
1) D56: BVM-20F1U/20E1U/14F1U/14E1U/14F5U/14E5U
D65: BVM-20F1E/20E1E/14F1E/14E1E/14F5E/14E5E
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Assigning the Remote Control Functions
— REMOTE Menu
Overview
The remote control functions are set with the
About monitor address and group numbers
REMOTE menu. With this monitor, both serial remote
control (REMOTE 1) and parallel remote control
(REMOTE 2) are possible. It is possible to
simultaneously use the REMOTE 1, and REMOTE 2
for control, but commands from REMOTE 2 have
priority. Therefore, it is impossible for the control
panel or REMOTE 1 to change items set by REMOTE
2.
There is no priority order between commands from
REMOTE 1 and the BKM-10R/11R control panel; it is
possible to set APERTURE to ON from REMOTE 1
and then set it to OFF with a control panel operation.
The BKM-10R/11R or HDM-14E5U, BVM-14E5U/
14E5E/14F5U/14F5E/14G5U/14G5E/14G5A are able
to control up to 32 monitors connected via serial
remote connector (using the REMOTE 1 connector).
By giving each monitor a monitor address and group
number, it is possible to control just a specific monitor
or monitor group.
With the REMOTE menu, each monitor can be set
with a monitor address and group number, between 1
and 99.
The ADDRESS menu is used to select a particular
monitor or group by entering a monitor number or
group number.
For details of the ADDRESS menu, see “Selecting the
Monitor to Control —ADDRESS Menu” on page 55.
Note
The address number must differ from one monitor to
another. If two or more monitors have the same
address number, an operation error occurs.
Structure of the SET UP Menu [C] / INPUT REMOTE Menu [C2]
Level 1
Level 2
Level 3
Level 4
INPUT CONFIGURATION C1
REMOTE C2
REMOTE 1 CONFIG C21
MONITOR ADDRESS
GROUP ADDRESS
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
REMOTE MODE C211
CH (1/2)
REMOTE 2 CONFIG C22
REMOTE 2
1 PIN C221
2 PIN
EXTEND MENU C7
BLUE ONLY (2/2)
3 PIN
4 PIN
5 PIN
6 PIN
7 PIN
8 PIN
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Constituent Menus of the SET UP / REMOTE Menu
This section describes the functions of the constituent
menus of the SET UP/REMOTE menu.
[C22] REMOTE 2 CONFIG menu
Select the REMOTE 2 connector pins for which you
want to change the function. The factory settings for
each pin are given below. ÷ [C211]
1 PIN...: CH01
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
2 PIN...: CH02
For details of menu numbers, see page 20.
3 PIN...: EXT SYNC
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
4 PIN...: MONO
5 PIN...: SAFE AREA
6 PIN...: unused
7 PIN...: unused
8 PIN...: TALLY
[C221](1/2) 1-8 PIN menu (1/2)
Assign a function to the selected pin.
CH: Select a channel number. Enter the desired
channel number with the numeric keypad.
----: Set to unused.
UNDERSCAN: Set underscan on or off.
16:9: Set a 16:9 aspect ratio on or off.
H DELAY: Set the horizontal sync display on or off.
V DELAY: Set the vertical sync display on or off.
EXT SYNC: Set the synchronization to external sync
signals enabled or disabled.
[C2] REMOTE menu
Select the type of remote control.
REMOTE 1 CONFIG...: Set the address and group
number of the monitor controlled via the
REMOTE 1 (serial remote control) connector. ÷
[C21]
REMOTE 2 CONFIG...: Set the pin assignments for
the REMOTE2 (parallel remote control)
connector. ÷ [C22]
REMOTE 2: Select whether or not parallel remote
COMB: Set the comb filter on or off.
APERTURE: Set the correction of frequency
characteristics enabled or disabled.
control will be used (ON or OFF).
[C21] REMOTE 1 CONFIG menu
Set the monitor address, group address and remote
mode of the monitor.
MONO: Set monochrome display on or off.
[C221](2/2) 1-8 PIN menu (2/2)
MONITOR ADDRESS: Enter a number.
GROUP ADDRESS: Enter a number.
REMOTE MODE: Select the remote mode. ÷
[C211]
Assign a function to the selected pin.
BLUE ONLY: Set the blue signal pictures display
(monochrome) on or off.
R OFF: Set cutting red beams enabled or disabled.
G OFF: Set cutting green beams enabled or disabled.
B OFF: Set cutting blue beams enabled or disabled.
VITC ON: Set the VITC display on or off.
SAFE AREA ON: Set the safe area display on or off.
CAPTION VISION: Set the caption vision on or off.
TALLY ON: Set tally signals on or off.
[C211] REMOTE MODE menu
Select a remote mode according to the type of
monitors connected through the REMOTE 1
connector.
When only Sony BVM-xxE/F/G or HDM-xxE
series monitors are connected: set REMOTE
MODE to 0.
DEGAUSS ON: Set degaussing on or off.
POWER OFF: Set the monitor power on or off.
When a Sony BVM-xx11/16 series monitor or a
Sony PVM monitor (with BKM-103 Serial
Remote Interface Kit installed) is connected:
set REMOTE MODE to 1 and enter a number
over 64 as the MONITOR ADDRESS for each
connected Sony BVM-xxE/F/G and HDM-xxE
series monitor.
For details of pin connections, see the description of the
REMOTE 2 connector on page 17.
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Password — PASSWORD Menu
Overview
A four-digit password can be specified and applied to
desired menu options to prohibit the menu settings
from being changed without permission. The password
is set with the PASSWORD menu.
A password is always assigned to the PASSWORD
menu (factory setting: 9999).
Use of the password
The message “ENTER PASSWORD” is displayed
when an attempt is made to select a menu item for
which the password has been applied. Then, enter the
password using numeric keypad.
A password for a service man can be created with the
MAINTENANCE menu.
If the password is not entered correctly
If an incorrect password is entered, the display returns
to the menu of the previous level.
Structure of the SET UP menu [C] / PASSWORD menu [C3]
Level 1
Level 2
Level 3
Level 4
Level 5
INPUT CONFIGURATION C1
REMOTE C2
ENTER
ENTER
PASSWORD C31
CHANGE
RE-ENTER
PASSWORD
PASSWORD C3
PASSWORD C3111
PASSWORD C311
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
APPLY
PASSWORD C312
CONTROL PRESET ADJ
COLOR TEMP ADJ
SET UP
EXTEND MENU C7
MEMORY CARD
COPY
KEY PROTECT
Constituent Menus of the SET UP / PASSWORD Menu
This section describes the functions of the constituent
menus of the SET UP/PASSWORD menu.
[C3] PASSWORD menu
Enter the password for the PASSWORD menu.
ENTER PASSWORD: Enter the password (factory
setting: 9999). ÷ [C31]
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
[C31] PASSWORD menu
For details of menu numbers, see page 20.
Choose what action to perform with the password.
CHANGE PASSWORD...: Change the password.
÷ [C311]
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
APPLY PASSWORD...: Assign the password to a
menu item. ÷ [C312]
[C311] CHANGE PASSWORD menu
Change the password.
ENTER NEW PASSWORD: Enter a password. ÷
[C3111]
40
Download from Www.Somanuals.com. All Manuals Search And Download.
[C3111] ENTER PASSWORD menu
Create a new password.
RE-ENTER PASSWORD TO CONFIRM : Enter
the new password again and press the ENTER
button. ÷ The password is recorded.
To change it, press the MENU button. ÷ Return to
[C31].
[C312] APPLY PASSWORD menu
Choose whether or not to apply the password to each
menu.
CONTROL PRESET ADJ: Select YES or NO.
CONTROL TEMP ADJ: Select YES or NO.
SET UP: Select YES or NO.
MEMORY CARD: Select YES or NO.
COPY: Select YES or NO.
KEY PROTECT: Select YES or NO.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Channel Selection Method and Power-
Up Conditions — SYSTEM CONFIGURATION Menu
Overview
The SYSTEM CONFIGURATION menu is used for
the following settings:
(5) AFC time constant
(6) Residual subcarrier detection (when using the
BKM-24N/25P)
It is possible to detect residual subcarrier signals from
phase change by setting the adaptor’s residual
subcarrier switch on.
(1) Channel number entry method
Select a method to enter channel numbers using the
ten-key pad, from two options.
(2) Power-up condition
This menu sets the condition of the monitor when the
MAIN POWER switch on the rear panel is switched
on.
(7) Auto chroma control (ACC) (when using the
BKM-27T)
(8) Holding the current contrast/brightness setting
after white balance adjustment
(3) Power-up input channel
Specify the channel to be selected automatically when
the power is turned on.
(9) Making a shortcut to a white balance
adjustment menu
(4) Time from power-up until degauss
Make the [F2] key a shortcut key to display the
COLOR TEMP ADJ MANUAL menu. This allows
you to jump directly to the MANUAL menu display
corresponding to the color temperature setting (STD/
COL 1/COL 2) for the currently displayed image.
If several monitors are turned on at the same time and
all start degaussing at the same time, there will be a
very large current draw on the power supply for a few
moments. To prevent this, the delay time between
power-up and degaussing can be set for each monitor
independently.
Structure of the SET UP Menu [C] / SYSTEM CONFIGURATION Menu [C4]
Level 1
Level 2
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
INPUT SELECT
STANDBY MODE
DEFAULT CH
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
DEGAUSS DELAY
AFC TIME
EXTEND MENU C7
RESIDUAL SC SW
ACC SW
CONT/BRT HOLD
COL TEMP SHORT-CUT
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Constituent Menus of the SET UP / SYSTEM CONFIGURATION Menu
This section describes the functions of the constituent
menus of the SET UP/SYSTEM CONFIGURATION
menu.
DEGAUSS DELAY: Set the time between power-up
and the beginning of degaussing. Enter the desired
time (in seconds).
AFC TIME: Select the AFC time constant (SLOW
or FAST).
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
RESIDUAL SC SW: Switch the residual switch
(OFF or ON).
For details of menu numbers, see page 20.
ACC SW: Switch the ACC switch (OFF or ON).
CONT/BRT HOLD: Select the contrast and
brightness settings to the center or adjusted value
after adjusting the white balance or auto
adjustment of CONTROL PRESET (OFF or ON).
ON: The contrast and brightness are set to the
value before adjusting.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
OFF: The contrast and brightness are set to the
center value (1000) after adjusting.
[C4] SYSTEM CONFIGURATION menu
Set each of the various items.
INPUT SELECT: Select the channel number entry
method (DIRECT or 10KEY).
COL TEMP SHORT-CUT: Assign the shortcut
function to the MANUAL menu of the COLOR
TEMP ADJ menu to [F2] key (OFF or ON).
ON: Assigns the shortcut to the MANUAL menu
of the COLOR TEMP ADJ menu.
(In the explanation below, x and y represent any
digit between 1 and 9.)
DIRECT mode: To select channel x, press the x
button. To select channel xy (a two-digit
channel number), press the 0, x, and y buttons
in this order.
OFF: Do not assign the shortcut to the
MANUAL menu of the COLOR TEMP ADJ
menu.
10KEY mode: To select channel x, press the x
button, then the ENTER button. To select
channel xy (a two-digit channel number), press
the x, y, and ENTER button in this order.
When multiple monitors are connected by a serial
remote connection, this setting will be common to
all the monitors. It is not possible to change the
setting for individual monitors.
STANDBY MODE: Select the power-up condition
when the MAIN POWER switch is turned on
(OFF or ON).
ON: Standby mode
OFF: Operation mode
DEFAULT CH: Select the power-up input channel
(LAST or CH xx).
LAST: Set the channel to the channel that was
selected at the time the power was last turned
off.
CH xx: Set the channel to a specific channel
number.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Screen Display — ON SCREEN SET
Menu
Overview
The ON SCREEN SET menu is used to select the type
of information that will be displayed on the screen and
how that information will be displayed. The types of
information that can be set are as follows.
(1) The VITC or user bit from the input signal
(2) Caption vision
(3) SDI signal ancillary data blanking (when using the
BKM-20D/21D)
(4) Channel number and name
Structure of the SET UP Menu [C] / ON SCREEN SET Menu [C5]
Level 1
Level 2
Level 3
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
VITC
VITC C51
USER BIT
EXTEND MENU C7
CAPTION 1
CAPTION 2
TEXT 1
CAPTION VISION C52
ANCILLARY DATA
TEXT 2
OFF
AUTO
ON
CH NO
C53
CH NAME
OFF
TL
VITC POSITION
C54
TC
TR
BL
BC
BR
CH NO POSITION
CH NAME POSITION
Constituent Menus of the SET UP / ON SCREEN SET Menu
This section describes the functions of the constituent
menus of the SET UP/ON SCREEN SET menu.
[C5] ON SCREEN SET menu
Select items to be displayed on the screen.
VITC...: Select whether or not to display the VITC
or user bit data contained in the input signal. ÷
[C51]
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
CAPTION VISION...: Select whether or not to
display the caption, and select the display mode.
÷ [C52]
ANCILLARY DATA: Select whether or not to
display the ancillary data in the serial digital
signal (OFF or ON).
CH NO...: Select the display mode of the channel
number. ÷ [C53]
44
Download from Www.Somanuals.com. All Manuals Search And Download.
CH NAME...: Select the display mode of the channel
name. ÷ [C53]
VITC POSITION...: Select the display position for
the VITC data. ÷ [C54]
CH NO POSITION...: Select the display position
for the channel number. ÷ [C54]
CH NAME POSITION...: Select the display
position for the channel name. ÷ [C54]
[C51] VITC menu
Select whether or not to display the VITC and user bit.
VITC: OFF or ON
USER BIT: OFF or ON
[C52] CAPTION VISION menu
Select the caption display mode.
OFF: Not displayed.
CAPTION 1: Displayed in Caption 1 mode.
CAPTION 2: Displayed in Caption 2 mode.
TEXT 1: Displayed in Text 1 mode.
TEXT 2: Displayed in Text 2 mode.
[C53] CH NO or CH NAME menu
Select the channel number and channel name display
mode.
AUTO: Disappear after displayed for a while.
ON: Displayed.
OFF: Not displayed.
[C54] VITC POSITION, CH NO POSITION or CH
NAME menu
Select the display position.
TL: Top left
TC: Top center
TR: Top right
BL: Bottom left
BC: Bottom center
BR: Bottom right
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Convergence Adjustments — ALIGNMENT Menu
Overview
The ALIGNMENT menu is used for adjusting
convergence and geometry.
Structure of the SET UP Menu [C] / ALIGNMENT Menu [C6]
Level 1
Level 2
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
ROTATION (1/4)
H PIN (2/4)
EXTEND MENU C7
V STATIC CON (3/4)
H CV R C (4/4)
Constituent Menus of the SET UP / ALIGNMENT Menu
This section describes the functions of the constituent
menus of the SET UP/ALIGNMENT menu.
[C6](1/4) ALIGNMENT menu (1/4)
Adjust each item with the UP and DOWN buttons or
PHASE knob.
ROTATION: Compensates for the screen rotation
which occurs when the monitor is installed facing
north or south.
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
H PHASE: Adjust the horizontal picture position.
V CENTER: Adjust the vertical picture position.
H SIZE: Adjust the width of the picture.
V SIZE: Adjust the height of the picture.
V LIN AMP: Adjust the vertical linearity of the
picture.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu
which appears or an operation which is executed
when you select that menu item or setting. If the
description of an item or setting is not followed by an
arrow, it indicates that selecting the item or setting
finishes the setting operation.
V LIN BAL: Adjust the balance of the vertical
linearity of the picture.
VITS BLK: Adjust vertical blanking so that VITS
signals are not visible in the upper part of the
screen.
SUB CONTRAST: Adjust the center value of the
contrast when the image size is changed.
This item cannot be selected when 4:3-NORM is
selected in the SCREEN MODE menu.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
[C6](2/4) ALIGNMENT menu (2/4)
Adjust each item with the UP and DOWN buttons or
PHASE knob.
[C6](4/4) ALIGNMENT menu (4/4)
Adjust each item with the UP and DOWN buttons or
PHASE knob.
H PIN: Correct side pincushion distortion.
H PIN BAL: Correct the balance of side pincushion
distortion.
H CORNER PIN: Correct pincushion distortion at
the corner of the picture.
H CENTER PIN: Correct center bow distortion.
H MID PIN: Correct pincushion distortion at the
middle of the picture.
H KEY: Correct trapezoid distortion.
H KEY BAL: Correct the balance of trapezoid
distortion.
H CV R C: Adjust horizontal convergence at the
center right of the screen.
H CV R T: Adjust horizontal convergence at the top
right of the screen.
H CV R B: Adjust horizontal convergence at the
bottom right of the screen.
H CV R M T: Adjust horizontal convergence at the
middle right between the top and the center of the
screen.
H CV R M B: Adjust horizontal convergence at the
middle right between the bottom and the center of
the screen.
H CV L C: Adjust horizontal convergence at the
center left of the screen.
H LIN: Correct horizontal linearity.
H LIN BAL: Correct the balance of horizontal
linearity.Monitor Memory Card Data Operations
H CV L T: Adjust horizontal convergence at the top
left of the screen.
H CV L B: Adjust horizontal convergence at the
bottom left of the screen.
[C6](3/4) ALIGNMENT menu (3/4)
Adjust each item with the UP and DOWN buttons or
PHASE knob.
V STATIC CONV: Adjust vertical static
convergence.
V CONV TOP: Adjust vertical convergence at the
top of the screen.
V CONV BOT: Adjust vertical convergence at the
bottom of the screen.
H CV L M T: Adjust horizontal convergence at the
middle left between the top and the center of the
screen.
H CV L M B: Adjust horizontal convergence at the
middle left between the bottom and the center of
the screen.
H STATIC CONV: Adjust horizontal static
convergence.
H CONV C T: Adjust horizontal convergence at the
top of the screen.
H CONV C B: Adjust horizontal convergence at the
bottom of the screen.
H CV C M T: Adjust horizontal convergence at the
middle between the top and the center of the
screen.
H CV C M B: Adjust horizontal convergence at the
middle between the bottom and the center of the
screen.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Extended Functions — EXTEND MENU
Overview
The following 4 functions can be executed with the
EXTEND menu.
(3)Restart the monitor.
(4)Automatically adjust the setup level and 100 IRE
level of the internal white signal which is used in
the COLOR TEMP ADJ menu [B].
(1)Restore factory default data for installed boards.
(2)Write monitor setting and adjustment data to the
BKM-12Y monitor memory card or read setting
and adjustment data from the card.
Structure of the SET UP Menu [C] / EXTEND Menu [C7]
Level 1
Level 2
Level 3
Level 4
Level 5
INPUT CONFIGURATION C1
REMOTE C2
PASSWORD C3
SYSTEM CONFIGURATION C4
ON SCREEN SET C5
ALIGNMENT C6
ENTER PASSWORD
C71
RE-LOAD FACTORY
DATA C711
SLOT1 CONTROL
SLOT2 SDI 4:2:2/4 FSC1)
SLOT6 VIDEO AMP
SLOT7 DEFLECTION
SLOT9 POWER
EXTEND MENU C7
C7111
Confirmation
message2)
SUPPLY
BACK UP SYSTEM
DATA C7121
MEMORY CARD
C712
RE-STORE SYSTEM
DATA C7122
Confirmation
message3)
RE-START MONITOR
C713
ADJ INT SIGNAL
C714
1) This is displayed when the BKM-21D is installed in the SLOT 2.
2) A message appears, requiring your confirmation. If you select
OK, data is reset and the monitor is automatically turned off and
on again. If you select CANCEL, then you will be back in the
RE-LOAD FACTORY DATA menu [C711].
3) A message appears, requiring your confirmation. If you select
OK, data is read out from the monitor memory card. If you
select CANCEL, then you will be back in the MEMORY CARD
menu [C712] .
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Constituent Menus of the SET UP / EXTEND Menu
This section describes the functions of the constituent
menus of the SET UP/EXTEND menu.
[C7111] SLOT1 to SLOT9
The following message appears, requiring your
confirmation about data reloading.
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
DATA RESET TO
ITS FACTORY SETTING
AND MONITOR WILL RESTART
ARE YOU SURE?
OK : ENTER KEY
CANCEL : MENU KEY
OK: To continue, press the ENTER button. ÷
Resets the data and automatically turn the monitor
off and on again.
CANCEL: To cancel, press the MENU button. ÷
Returns to the RE-LOAD FACTORY DATA
menu. ([C711])
[C7] EXTEND menu
Enter the password (ENTER PASSWORD [C71]).
When the correct password is entered, the following
item appears. Choose the function to execute.
RE-LOAD FACTORY DATA...: Restore factory
default data for the board installed in the selected
slot. ÷ [C711]
MEMORY CARD...: Read and write setting and
adjustment data by using the monitor memory
card. ÷ [C712]
[C712] MEMORY CARD menu
Insert the monitor memory card into the MEMORY
CARD slot and select the operation to perform.
BACK UP SYSTEM DATA...: Write the data to the
monitor memory card. ÷ [C7121]
RE-STORE SYSTEM DATA...: Read the data from
the monitor memory card. ÷ [C7122]
RE-START MONITOR: Restart the monitor. ÷
[C713]
Notes
ADJ INT SIGNAL: Automatically adjust the
SETUP level and 100 IRE level of internal
signals. ÷ [C714]
• Before a monitor memory card can be used, it must
be formatted it with the FORMAT menu ([D4]).
• System data and memory card data ([D]) cannot be
stored on the same memory card. To store memory
card data, use another memory card.
• The BKM-12Y monitor memory card has a capacity
of 256 Kbytes. It can store either system data for up
to 8 monitors or 38 files of memory card data.
[C711] RE-LOAD FACTORY DATA menu
Select a slot where a board is installed to reload factory
default data to the board. ÷ [C7111]
Note
You can only select slots 6 and 7. However, when the
optional board has been installed, you can also select
slot 2.
[C7121] BACK UP SYSTEM DATA menu
While the system is writing the data, a “–” mark blinks
at the top right of the menu. (It takes some time to save
the data.)
BACK UP SYSTEM DATA
IN PROGRESS...SYSTEM
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Extended Functions — EXTEND MENU
[C7122] RE-STORE SYSTEM DATA
The following message appears, requiring your
confirmation about data reloading.
RE-STORE SYSTEM DATA
ALL DATA WILL BE
RESTORED
ARE YOU SURE?
OK : ENTER KEY
CANCEL : MENU KEY
OK: To continue, press the ENTER button. ÷ Read
the data from the monitor memory card and
automatically turn the monitor off and on again.
CANCEL: To cancel, press the MENU button. ÷
Return to the MEMORY CARD menu ([C712]).
[C713] RE-START MONITOR
Turn the monitor off and on again automatically.
[C714] ADJ INT SIGNAL
Adjust the SETUP level and 100 IRE level of the
internal white signal which is used with the COLOR
TEMP ADJ menu [B].
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitor Memory Card Data Operations
— MEMORY CARD Menu
Overview
Operations on monitor memory card data are
performed with the MEMORY CARD menu.
Structure of the MEMORY CARD Menu [D]
Main menu
Level 1
Level 2
Level 3
MEMORY CARD D
SAVE D1
NEW NAME
FILE NAME
FILE NAME
FILE NAME
LOAD D2
DELETE D3
FORMAT D4
Confirmation
message
Confirmation
message
Constituent Menus of the MEMORY CARD Menu
This section describes the functions of the constituent
menus of the MEMORY CARD menu.
[D2] LOAD menu
Select the name of the file from which to read data.
Notes
[D3] DELETE menu
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
Select the name of the file to delete.
The following confirmation message appears.
DELETE THIS FILE?
OK: ENTER KEY
CANCEL: MENU KEY
OK: To continue, press the ENTER button. ÷ The
file is deleted.
CANCEL: To cancel, press the MENU button. ÷
Return to the MEMORY CARD menu [D]
[D] MEMORY CARD menu
[D4] FORMAT menu
Select the operation to perform. (It takes some time to
load and save the data.)
SAVE: Write data to a monitor memory card. ÷ [D1]
LOAD: Read data from a monitor memory card. ÷ [D2]
DELETE: Delete a file. ÷ [D3]
Confirm the format operation.
ALL FILES WILL BE DELETED!
ARE YOU SURE?
OK: ENTER KEY
CANCEL: MENU KEY
FORMAT: Format a monitor memory card. ÷ [D4]
OK: To continue, press the ENTER button. ÷ The
format is performed.
[D1] SAVE menu
Select the name of the file to which to write data,or
create a new file name.
CANCEL: To cancel, press the MENU button. ÷
Return to the MEMORY CARD menu [D].
NEW NAME: Enter a new name (max. 20
characters).
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitor-to-Monitor Data Copy — COPY Menu
Overview
When multiple monitors are connected via their serial
remote ports, data can be shared between the monitors
by data copy. The data copy from one monitor to
another is accomplished with the COPY menu.
Structure of the COPY Menu [E]
Main menu
Level 1
Level 2
MONITOR ADDRESS E1
ALL
COPY E
CONTROL PRESET
CONTROL TEMP
SET UP
Constituent Menus of the COPY Menu
This section describes the functions of the constituent
menus of the COPY menu.
[E1] MONITOR ADDRESS menu
Select the data to be copied. ÷ Copy is carried out.
ALL: Copy data for all menu settings.
CONTROL PRESET: Copy the data for the
CONTROL PRESET ADJ menu settings.
COLOR TEMP: Copy the data for the COLOR
TEMP ADJ menu settings.
Notes
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
SET UP: Copy the data for the SET UP menu
settings.
[E] COPY menu
Select the copy source monitor.
MONITOR ADDRESS: Enter the address number.
÷ [E1]
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Displaying Information About the Monitor
— STATUS Menu
Overview
The STATUS menu is used to view general data about
the monitor and information about signals assigned to
the slots in the rear panel.
Structure of the STATUS Menu [F]
Main menu
Level 1
Level 2
Level 3
STATUS (1/3) F1
STATUS (2/3) F2
STATUS (3/3) F3
CH STATUS F11
MODEL NAME
SLOT STATUS F31
CH
STATUS F
MODEL NAME
SERIAL NO
Constituent Menus of the STATUS Menu
This section describes the functions of the constituent
menus of the STATUS menu.
[F2] STATUS menu (2/3)
Data about the monitor is displayed.
MODEL NAME: model name
Notes
SERIAL NO: serial number
• The menu numbers (A, B1, C11 and so on) are not
displayed on the monitor screen.
OPERATION TIME: operation time (in hours)
SOFTWARE VERSION: software version
For details of menu numbers, see page 20.
• An arrow (÷) following the description of an item
or setting in each menu indicates another menu which
appears or an operation which is executed when you
select that menu item or setting. If the description of
an item or setting is not followed by an arrow, it
indicates that selecting the item or setting finishes the
setting operation.
[F3] STATUS menu (3/3)
Display the current assignments of options to slots at
the rear. (When the BKM-21D is installed in SLOT 2,
the display is as shown below. When not, “EMPTY” is
displayed as status of SLOT 2.
SLOT 1: CONTROL
SLOT 2: SDI 4:2:2/4FSC
SLOT 3: EMPTY
SLOT 4: EMPTY
SLOT 5: EMPTY
[F] STATUS menu
Select the STATUS menu. ÷ [F1]
SLOT 6: VIDEO AMP
SLOT 7: DEFLECTION
SLOT 8: EMPTY
SLOT 9: POWER SUPPLY
[F1] STATUS menu (1/3)
Specify the channel block to be detected from channel
1 to channel 99.
[F11] CH STATUS menu (1/3)
Data about the current channel is displayed.
CH: channel number
[F31] SLOT STATUS menu
Select the desired slot. Data about the optional board
installation in the selected slot is displayed.
MODEL NAME: Model name of that optional board
SERIAL NO: Serial number of that circuit board
SL: slot number
IN: input connector number
FORMAT: format of the input signal
NAME: channel name
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Selecting the Monitor to Control — ADDRESS
Menu
By pressing the ENTER button after selecting the item,
serial remote operation becomes activated.
Overview
A D D R E S S
When multiple monitors are connected by a serial
remote connection, the ADDRESS menu is used to
choose whether one particular monitor or monitor
group will be controlled, or whether operations are to
be performed on all monitors together.
S I N G L E
G R O U P
A L L
* *
* *
A L L P O W E R O N
A L L P O W E R O F F
Displaying the ADDRESS Menu
D I S P L A Y M O N I T O R A D D R E S S
D I S P L A Y G R O U P A D D R E S S
S E T U P P V M ( B K M - 1 0 3 )
Press the ADDRESS button.
The ADDRESS button lights, and the ADDRESS
menu is displayed on the screen.
ADDRESS Menu
Settings made with the menu items are as follows:
Item
Function
SINGLE
Control only a specified monitor. Enter the monitor address number.
Control only a specified monitor group. Enter the group address number.
Control all monitors.
GROUP
ALL
Turn all connected monitors on.
ALL POWER ON
ALL POWER OFF
DISPLAY MONITOR ADDRESS
Turn all connected monitors off.
When this item is selected, each connected monitor displays its monitor address on its
screen.
When this item is selected, each connected monitor displays its group address on its screen.
DISPLAY GROUP ADDRESS
SET UP PVM (BKM-103)
Transfer the INPUT CONFIG settings of a BVM monitor to a PVM monitor. The BKM-103
Serial Remote Interface Kit must be installed in the PVM monitor, and the monitor address
of the PVM monitor must be selected using the SINGLE menu item.
In case of SHIFT ON before remote control
Notes
operation: LEDs light in orange when the SHIFT
button is remotely set to ON.
• To remotely control monitors connected in serial,
MONITOR ADDRESS or GROUP ADDRESS of
monitors should be correctly set in the REMOTE
For details, see “SHIFT button” on page 12.
• In SINGLE mode, when the data is saved or load in
or from the memory card, the error message may
appear due to data communication error. In such a
case, clear the remote mode, then try again.
It is recommended to save or load data to or from the
memory card with the monitor which is free from the
remote operation.
• When Sony BVM-xxG series monitors are connected
together, select these monitors for each series in
SINGLE mode or GROUP mode to remotely control
them.
menu.
For details of the REMOTE menu, see “Assigning the
Remote Control Functions – REMOTE Menu” on page 38.
– In GROUP mode, when the KEY PROTECT
function is set to ON, the LED on the pressed
function button lights, but it is deactivated. (LED
of other monitors in the same group will not light.)
– In GROUP or ALL mode, the LEDs of the
function buttons will not light with controlled
from the menu. (LEDs light only when you press
the function button.)
– In GROUP or ALL mode, LEDs of controlled
monitor will light as follows.
In case of SHIFT OFF before remote control
operation: LEDs light in green when the SHIFT
button is remotely set to OFF.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Cancelling the Remote Control
Mode
Short-cut Function in the
ADDRESS Menu
To cancel the remote control mode, press the
ADDRESS button.
When selecting the monitor, short-cut function will
enable to select the target monitor without using the
items in the ADDRESS menu. The operation
procedure is as follows.
Exiting the ADDRESS Menu
To select the monitor in the SINGLE mode
To exit the ADDRESS menu, press the ADDRESS
button or the MENU button.
1 Press the ADDRESS button.
2 Press the address number of the target monitor.
Press one digit address number on the numeric
keypad when it is from 1 to 9.
Press three digits address number (press 0 button
and then press the address number) when it is from
10 to 99.
To select the monitors in the GROUP mode
1 Press the ADDRESS button.
2 Press the F1 button.
3 Press the group number of the target monitor.
Press one digit group address number when it is
from 1 to 9.
Press three digits group address number (press 0
button and then press the group number) when it is
from 10 to 99.
To select the all monitors in the ALL mode
1 Press the ADDRESS button.
2 Press the F2 button.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Effective picture size:
267 × 200 mm (10 5/8
7 7/8 inches) (w/h)
General
×
System
CRT
525 lines, 60 fields per second
interlaced
625 lines, 50 fields per second
interlaced
Super fine pitch Trinitron
BVM-20F1U/20F1E/20E1U/
20E1E
331 mm (13 1/8 inches) (diagonal
size)
CRT protection: EHT (extremely
high tension) protectiontype
Warm-up time: approx. 30 minutes
Anode voltage: 25 kV with no
beam current
Aperture grille pitch: 0.3 mm
(BVM-20F1U/20F1E) or
0.25 mm (BVM-20E1U/
20E1E), 90 degree deflection,
30.6 mm diameter in-line gun.
Effective picture size:
Nominal chromaticity coordinates:
SMPTE phosphor (BVM-14F1U/
14E1U)
x
y
R
G
B
0.630
0.310
0.155
0.340
0.595
0.070
387 × 291 mm (151/4 ×
111/2 inches) (w/h)
483 mm (19 1/8 inches) (diagonal
size)
EBU phosphor (BVM-14F1E/14E1E)
CRT protection: EHT (extremely
high tension) protection type
Warm-up time: approx. 30 minutes
Anode voltage: 27 kV with no
beam current
x
y
R
G
B
0.640
0.290
0.150
0.330
0.600
0.060
Nominal chromaticity coordinates:
Power requirements
Power consumption
100 to 240 V AC, 10%, 50/60 Hz
SMPTE phosphor (BVM-20F1U/
20E1U)
BVM-20F1U/20F1E/20E1U/
20E1E: 120 W
When an optional adaptor is
installed: 200 W
BVM-14F1U/14F1E/14E1U/
14E1E: 110 W
When an optional adaptor is
installed: 145 W
x
y
R
G
B
0.630
0.310
0.155
0.340
0.595
0.070
Error: less than ±0.005
EBU phosphor (BVM-20F1E/20E1E)
BVM-14F5U/14F5E/14E5U/
14E5E: 110 W
When an optional adaptor is
installed: 175 W
x
y
R
G
B
0.640
0.290
0.150
0.330
0.600
0.060
Peak inrush current
(1) Power ON, current probe method:
55A (240V) (BVM-20F1E/20E1E/14F5E/
14E5E/14F1E/14E1E)
(2) Hot switching inrush current, measured in
accordance with European standard
EN55103-1: 50A (230V) (BVM-20F1E/
20E1E), 38A (230V) (BVM-14F5E/14E5E/
14F1E/14E1E)
Error: less than ±0.005
BVM-14F1U/14F1E/14E1U/
14E1E//14F5U/14F5E/14E5U/
14E5E
Aperture grille pitch: 0.25 mm
(BVM-14F1U/14F1E/14F5U/
14F5E) or 0.22 mm (BVM-
14E1U/14E1E/14E5U/14E5E),
90-degree deflection, 29.4 mm
diameter in-line gun.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Dimensions
BVM-20F1U/20F1E/20E1U/20E1E:
BVM-14F5U/14F5E/14E5U/14E5E
Unit: mm (inches)
444 × 414 × 570 mm
(17 1/2 × 16 3/8 × 22 1/2 inches)
(w/h/d)
482 (19)
426 (167/8)
410 (161/4)
BVM-14F1U/14F1E/14E1U/14E1E:
346 × 280 × 530 mm (13 5/8 × 111/8
× 20 7/8 inches)
(w/h/d)
BVM-14F5U/14F5E/14E5U/14E5E:
482 × 280 × 573 mm (19 × 111/8
×
22 5/8 inches)
(w/h/d)
Dimensional drawing
BVM-20F1U/20F1E/20E1U/20E1E
Mass
BVM-20F1U/20F1E/20E1U/
20E1E: approx. 37 kg (81 lb
9 oz)
BVM-14F1U/14F1E/14E1U/
14E1E: approx. 22 kg (48 lb
8 oz)
Unit: mm (inches)
444 (171/2)
410 (161/4)
BVM-14F5U/14F5E/14E5U/
14E5E: approx. 25 kg (55 lb
1 oz)
Input/output Connectors
Video input
BNC type, 3 (with three loop-
through outputs)
30 (13
/
)
16
30 (13
/
)
16
R/G/B: 1 Vp-p ±6 dB, positive,
high impedance
26 (11
/
)
16
26 (11
/
)
16
BVM-14F1U/14F1E/14E1U/14E1E
Y: 1 Vp-p ±6 dB, positive, high
impedance
R–Y/B–Y: 0.7 Vp-p ±6 dB,
positive, high impedance
BNC type, 1 (with loop-through
output)
Unit: mm (inches)
346 (135/8)
330 (13)
Sync input
Composite sync: 0.3 to 8 Vp-p,
negative, high impedance
More than 46 dB (7 MHz, with
75-ohm termination)
Return loss
Remote control
OPTION
Mini-DIN 8-pin, 1
CONTROL UNIT
D-sub 9-pin, 1 (only on BVM-
20F1U/20F1E/20E1U/20E1E/
14F1U/14F1E/14E1U/14E1E)
REMOTE 1
D-sub 9-pin, 1 (with loop-
through output), RS-485 serial
interface
58
Download from Www.Somanuals.com. All Manuals Search And Download.
REMOTE 2
Convergence error
D-sub 9-pin, 1 (with loop-
through output)
ISR
Within a central area bounded by a
circle with a diameter equal to the
picture height:
D-sub 9-pin, 1
Less than 0.4 mm (BVM-20F1U/
20F1E/20E1U/20E1E)
Video Signal
Less than 0.3 mm (BVM-14F1U/
14F1E/14E1U/14E1E/14F5U/
14F5E/14E5U/14E5E)
Outer area of the above-mentioned
circle:
Less than 0.7 mm (BVM-20F1U/
20F1E/20E1U/20E1E)
Less than 0.6 mm (BVM-14F1U/
14F1E/14E1U/14E1E/14F5U/
14F5E/14E5U/14E5E)
Differential gain Less than 2% (for luminance from
0 to 100 cd/m2)
Differential phase Less than 2˚ (for luminance from 0
to 100 cd/m2)
Frequency response
50 Hz to 10 MHz, ±1 dB
Back porch type
Black level fluctuation: less than
1% for 10 to 90% APL input
signal variation.
DC restoration
Standard luminescence
100 cd/m2 (at standard 1 Vp-p
100% white signal)
Raster size stability
Scan delay
Synchronization
Less than 1% of picture height (at
100 cd/m2 peak luminescence, 10
to 90% APL)
AFC time Constant
0.5 ms (fast mode)
2 ms (normal mode)
Line pull range/line hold range
Greater than ±500 Hz (with 0.5 ms
AFC time constant)
Vertical blanking time
Normal: less than 1 ms.
Underscan: less than 0.8 ms
Horizontal blanking time
Less than 10 µs
Horizontal: Approx. 1/4 line
Vertical: Approx. 1/2 field
Resolution (at screen center, 100 cd/m2 luminescence)
BVM-20F1U/20F1E: 900 TV lines
BVM-20E1U/20E1E: 1000 TV
lines
BVM-14F1U/14F1E/14F5U/
14F5E: 800 TV lines
BVM-14E1U/14E1E/14E5U/
14E5E: 900 TV lines
Picture Performance
Operating Conditions
Normal scan
Underscan
Linearity
5% overscan of CRT effective
screen area (adjustable range
greater than ±15%)
3% underscan of CRT effective
screen area (adjustable range
greater than ±15%)
Within a central area bounded by a
circle with a diameter equal to the
picture height, less than 0.5% of
the picture height, and outside the
same area, about 1% of the
picture height
Temperature
Optimum temperature
20°C to 30°C (68°F to 86°F)
0°C to 35°C (32°C to 95°F)
Humidity
Pressure
0% to 90% (no condensation)
700 hPa to 1060 hPa
Storage and transport conditions
Temperature
Humidity
Pressure
–10 °C to +40°C (14°F to 104°F)
0% to 90%
700 hPa to 1060 hPa
Color temperature
D65, D93 (adjustable to other color
temperatures)
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Accessories Supplied
AC power cord (1)
Cord stopper (1)
Tally plate (1)
Fuse (1)
Operation manual (1)
Design and specifications are subject to change
without notice.
Connection Cable Specifications for Color Temperature Probes
Special cables are required to connect color
temperature probes other than the Sony BKM-14L to
the monitor.
The following diagrams show specifications and pin
assignments for the required cables.
Connection cable for Graseby SLS 9400 probe
Modular connector
Mini DIN 8-pin connector
(male)
1
6
1
2
5
3
6
8
Pin Number
Signal
H SYNC
V SYNC
RTS
Signal
N.C.
GND
RXD
TXD
GND
N.C.
Pin Number
1
2
3
4
5
6
1
2
3
4
5
6
7
8
GND
N.C.
TXD
+5V
RXD
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection cable for Minolta CA-100 probe
D-sub 25-pin connector
(male)
Mini DIN 8-pin connector
(male)
1
13
1
2
5
3
14
25
6
8
Pin Number
Signal
Signal
H SYNC
V SYNC
RTS
Pin Number
1
1
2
3
4
5
6
7
8
N.C.
TXD
RXD
RTS
CTS
N.C.
GND
N.C.
2
3
4
5
GND
N.C.
6
TXD
7
+5V
8–25
RXD
Connection cable for Philips PM 5639 probe (corresponds to Philips PM 5639/64 cable)
Modular connector
Mini DIN 8-pin connector
(male)
1
6
1
2
5
3
6
8
Pin Number
Signal
H SYNC
V SYNC
RTS
Signal
+5V
Pin Number
1
2
3
4
5
6
1
2
3
4
5
6
7
8
N.C.
RXD
TXD
N.C.
GND
GND
N.C.
TXD
+5V
RXD
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Connection cable for Thoma TF6 probe
D-sub 15-pin connector (female)
Mini DIN 8-pin connector (male)
1
8
1
2
5
3
9
15
6
8
Signal
H SYNC
V SYNC
RTS
Pin Number
Pin Number
Signal
N.C.
RXD
TXD
N.C.
N.C.
N.C.
GND
N.C.
1
1
2
3
4
5
6
7
8
2
3
4
5
GND
N.C.
6
TXD
7
+5V
8–15
RXD
62
Download from Www.Somanuals.com. All Manuals Search And Download.
The material contained in this manual consists of
information that is the property of Sony Corporation and is
intended solely for use by the purchasers of the equipment
described in this manual.
Sony Corporation expressly prohibits the duplication of any
portion of this manual or the use thereof for any purpose
other than the operation or maintenance of the equipment
described in this manual without the express written
permission of Sony Corporation.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation et
sont destinées exclusivement à l’usage des acquéreurs de
l’équipement décrit dans ce manuel.
Sony Corporation interdit formellement la copie de quelque
partie que ce soit de ce manuel ou son emploi pour tout
autre but que des opérations ou entretiens de l’équipement
à moins d’une permission écrite de Sony Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind,
und ausschließlich zum Gebrauch durch den Käufer der in
dieser Anleitung beschriebenen Ausrüstung bestimmt sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als die
Bedienung oder Wartung der in dieser Anleitung
beschriebenen Ausrüstung ohne ausdrückliche schriftliche
Erlaubnis der Sony Corporation.
Download from Www.Somanuals.com. All Manuals Search And Download.
BVM-20F1U/20F1E/20E1U/20E1E
BVM-14F1U/14F1E/14E1U/14E1E
BVM-14F5U/14F5E/14E5U/14E5E
Sony Corporation
B & P Company
Printed in Japan
2004.02.08
1995
(WW,
)
3-800-958-08(1)
Download from Www.Somanuals.com. All Manuals Search And Download.
|