Sherwood Scuba Diving Equipment SRB3108 User Manual

®
REGULATORS  
®
MINIMUS  
SHADOW  
(SRB3108)  
(SRB3209)  
Assembly & Maintenance Guide  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
This manual is a guide for the annual servicing and maintenance of the Sherwood SR3108 Minimus and  
SR3209 Shadow+ regulators. It gives breakdowns of regulator parts, equipment specifications, servicing  
instructions, troubleshooting recommendations, and guidelines for proper care of these regulators. This manual  
is intended for use only by persons specially trained and authorized to service Sherwood Scuba equipment.  
Because of the many unique features found only in Sherwood regulators, Sherwood conducts seminars on  
a regular basis throughout North America to train technicians in proper service and repair procedures for all  
current Sherwood regulators. In addition, all Sherwood dealers and their staff members are encouraged to  
attend the seminars to gain an in-depth understanding of the construction, special features and operation of  
Sherwood regulators.  
NOTE: You must be authorized by Sherwood to work on Sherwood Scuba equipment. You can obtain  
proper authorization by attending all appropriate seminars given in your area. This is the only way you can  
become an authorized Sherwood technician.  
For information on the dates and locations of upcoming Sherwood service seminars near you, contact your  
Sherwood Distributor or Sherwood Sales Representative.  
IMPORTANT  
Anyone attempting to service or repair Sherwood Scuba regulators must have a thorough understanding  
of the principles of operation of scuba regulators and valves, as well as the appropriate mechanical ability. The  
technician must also be properly trained in the safe use of compressed air and the various tools and cleaning  
solutions involved in the procedures outlined in this manual.  
SPECIFICATIONS  
REGULATOR MODEL . . . . . . . . . . . . . . . .Sherwood SR3108 Minimus & SR3209 Shadow+  
AIR FLOW . . . . . . . . . . . . . . . . . . . . . . . . .29 cu. ft. / min. @ 1 atmosphere  
INHALATION RESISTANCE . . . . . . . . . . .1.5" w.c @ 1 atmosphere  
EXHALATION RESISTANCE . . . . . . . . . . .0.8" w.c. max. @ 1 atm.  
RECOMMENDED LUBRICANTS . . . . . . . .LTI Christo-Lube #1110, Dow Corning 111 Compound®, Parker  
Super O-Lube®, or equivalent  
TYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . .Downstream valve, diaphragm, with Variable Fulcrum  
U.S. Pat. #3,991,785  
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . .4.2 oz. (octopus w/o main hose  
8.1 oz. (Shadow+ w/o main hose)  
HOSE LENGTH . . . . . . . . . . . . . . . . . . . . .36 in.  
MATERIALS . . . . . . . . . . . . . . . . . . . . . . .Cover - Thermoplastic Triax  
Case - Thermoplastic Triax®  
Poppet Seat - Liquid Silicone Tm Rubber  
0-rings - Buna-N®  
Diaphragm - Tufel® (Blue)  
Exhaust Valve - Thermoplastic Elastomer  
Mouthpiece - C-Flex®  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
TOOLS REQUIRED FOR MINIMUS & SHADOW+ SERVICING  
# 10 Torx Screwdriver (Sherwood Tool TL117)  
Phillips screwdriver  
3/4" wrench  
5/8" wrench  
9/16" wrench  
Side cutting pliers  
Sherwood In-line Adjusting Tool ( p/n TL102)  
Sherwood Plastic Probe (p/n TL111) to push out orifice  
Sherwood Lever Height Adjusting Tool (TL123)  
Sherwood Stem Socket Tool (p/n TL124)  
DISASSEMBLY  
To view the complete parts list of the second stage, fold out the front cover of this manual.  
(1) Pull back the hose protector (Item 21) from the inlet end ferrule. Remove the hose assembly (Item 20)  
from the orifice housing (Item 16) using a 3/4" and a 5/8" wrench. Inspect the hose assembly for any cuts or  
cracks, especially on the hose at the metal ferrules. Replace the hose assembly if any cuts or cracks are  
found.  
(2) Remove the mouthpiece (Item 15) by cutting the mouthpiece tie (Item 14) with side cutting pliers.  
Discard the old mouthpiece tie. Examine the condition of the mouthpiece. Pay particular attention to the area  
on top just behind where the old tie tightened. This is a prime area for small holes to develop. If the mouthpiece  
is in good condition, it can be reused.  
(3) Pry out the exhaust grid (Item 10) with a small screwdriver.  
(4) Use a #10 Torx (or small slot) screwdriver to remove the four screws (Item 12) holding the front cover  
(Item 1) in place.  
(5) Gently remove the diaphragm (Item 2) from the cover. Hold the diaphragm up to a light source. Gently  
stretch the diaphragm and look for tears or pinholes. If any are found, replace the diaphragm. Otherwise, the  
diaphragm can be reused.  
Note: If the unit is a SR3209 Shadow+, at this point you should pull off the swivel (Item 26, Fig. 1) from  
the orifice housing (Item 23). Inspect the inner bore of the swivel for any scratches that may have caused air  
leakage. Remove and inspect the O-rings (Items 24 & 25) from the orifice housing. Replace them if any wear  
or deformation of the O-rings is found. Remove the short hose assembly (Item 27) from the swivel using a  
9/16" wrench. Inspect the hose for kinks and bulges.  
(6) Hold the case in one hand and use a 3/4" wrench to loosen and remove the orifice housing from the  
lever assembly. The case is strengthened at the lever support area to withstand the turning forces of the lever  
support when this is done.  
(7) Use the Sherwood in-line adjusting tool (p/n TL102) to, back the adjusting orifice (Item 18) out of the  
orifice housing until the threads disengage. Remove the in-line adjusting tool, and push the adjusting orifice the  
rest of the way out of the orifice housing with the Sherwood plastic probe (p/n TL111).  
(8) Remove the O-ring (Item 19) from the adjustable orifice.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
(9) Before removing the exhaust valve (Item 12) from the case, bend it over as far as it will go from the  
top, bottom, left and right sides. If it fails to snap back quickly, and does not lie perfectly flat against the case,  
the valve should be replaced. If it does snap back satisfactorily, remove it and inspect the sealing edges. If  
they appear smooth, and the locking tab on the nipple is good, the valve can be reused.  
(10) Remove the lever support from the inside of the case (Item 13).  
(11) Normally, you will simply need to change the poppet stem seat insert (Item 9) to restore the second  
stage to maximum performance. To change the stem seat insert (Item 9), leave the lever assembly together.  
With a penknife or similar object, carefully remove the old seat insert. Put the new seat insert on a clean flat  
surface and lower the poppet cavity (from which the old seat insert was removed) over the new seat insert.  
(12) If parts of the lever assembly (stem, spring, lever, etc.) need to be replaced, take apart the assembly  
with the Sherwood stem socket tool (p/n TL124). Clamp the stem socket tool in a bench vice. Insert the square  
head of the poppet stem into the tool. With a Phillips screwdriver, loosen the screw (Item 3) that holds  
the assembly together two turns only.  
(13) Re-install the orifice housing onto the lever support (without the case) turning the two parts together  
firmly by hand. This will cause the poppet (Item 8) to be pushed out farther than normal by the orifice. This in  
turn will cause the lever to go limp.  
NOTE: If only the lever (Item 5) is to be replaced, do not totally remove the screw. You can now remove  
the lever from under the washer and replace it with a new lever. If other parts such as the spring (Item 7) are  
to be replaced, remove the screw (Item 3) fully. Then remove the orifice housing from the lever assembly to  
get these parts out.  
(14) Rinse all plastic and silicone parts in clean fresh water, and then blow the parts dry with compressed  
air to remove any sand and dust particles.  
(15) If necessary, clean all metal parts of the second stage in an ultrasonic cleaner or cleaning solution.  
Remove the O-rings before cleaning any metal parts; most cleaning solutions are damaging to the O-ring  
material. See page 7 for recommendations on cleaning solutions.  
NOTE: If you use an ultrasonic cleaner to clean the adjustable orifice (Item 18), use a plastic container to  
prevent the orifice from vibrating against other metal parts which could damage the orifice seal.  
(16) Inspect the case (Item 13) for any cracks. Look particularly closely at the area where the orifice  
housing and the lever support clamp down. Replace the case if any cracks are found.  
(17) Inspect the orifice's (Item 18) sealing cone (where the poppet insert seals) for any nicks, scratches, or  
corrosion. Corrosion or minor scratches can be polished out using a fine-grit rubberized polishing stick or a  
clean new pencil eraser.  
Do not apply heavy pressure when rotating the polishing stick. Stop polishing immediately after the  
corrosion or scratch disappears. Blow all dust and debris out of the orifice housing with clean compressed air.  
NOTE: Prior to this point, you should have cleaned and inspected all parts, following proper servicing  
procedures. Do not continue until this has been done.  
ASSEMBLY  
(1) Re-install the cleaned and lubricated O-ring (Item 19) onto the adjustable orifice (Item 18). Install the  
adjustable orifice back into the orifice housing. Push it in with your finger as far as it will go.  
(2) Install the exhaust valve (Item 12) into the case by inserting the nipple into the small hole from the  
outside of the case. Reach inside the case and pull the nipple firmly with the fingers until you hear or feel it  
"click" into place. Inspect the exhaust valve to see that it is properly seated.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3) Snap the exhaust grid (Item 10) back into its slots. Make sure it is properly seated.  
(4) Install the lever assembly into the case.  
(5) Screw the orifice housing (Item 16) onto the threads of the lever assembly. Hold the case (Item 13) in  
one hand. Use a 3/4" wrench on the orifice housing. Tighten the orifice housing and the lever assembly  
together snugly (70 in. lbs.).  
Note: Do not allow lubrication (grease on fingers, or silicone over-spray) to get on the case (Item 13), the  
diaphragm (Item 2), or the exhaust valve (Item 11) as it may cause slippage or deterioration of these parts.  
Note: If the unit is a SR3209 Shadow+, the O-rings (Items 24 & 25) should now be lubricated and  
replaced onto the orifice housing (Item 23). The larger of the two O-rings goes on closest to the case (Item  
13). Install the short hose assembly onto the swivel (Item 26). Lubricate the inner bore of the swivel. Re-install  
the swivel back onto the orifice housing.  
Note: The following steps (5-8) are included here for continuity. They must be performed after the regulator  
second stage is adjusted (see "Set-Up of Second Stage," page 4).  
(6) Install the diaphragm (Item 2) into the case so that it sits evenly on the ledge.  
(7) Install the cover (Item 1) onto the case by sliding it carefully and firmly into place.  
(8) Install the four screws (Item 12) that hold the cover onto the case using a # 10 Torx screwdriver  
(Sherwood Tool TL117) or a small slotted screwdriver.  
CAUTION! DO NOT OVER-TIGHTEN. These screws are threading into plastic, which will hold well in  
service but can be stripped if over-tightened.  
(9) Install the mouthpiece (Item 15) and mouthpiece tie (Item 14).  
SET- UP  
NOTE: For the following adjustments, remove the cover and diaphragm.  
(1) Install Sherwood's in-line adjusting tool (p/n TL102) between the orifice housing (Item 16) and the hose  
assembly (Item 20). Use the tool to screw the adjustable orifice (Item 18) clockwise. Watch the end of the lever  
(Item 5) as you do this. As soon as the tip of the lever begins to drop, stop turning the tool.  
NOTE: The slight amount of friction this operation produces between the orifice and the stem seat will not  
harm the stem seat.  
(2) Attach the second stage to its accompanying overhauled and properly adjusted first stage, and mount  
on an air tank filled to between 2700 and 3500 psig.  
(3) Slowly turn on the tank valve. If you hear any leaks, determine the location of the leak, shut the air  
off, and repair the leak as necessary.  
(4) Turn on the air. Use the in-line adjusting tool to turn the adjusting orifice (Item 18) counter-clockwise  
until you hear a slight hissing. Then turn the adjusting orifice clockwise just enough to stop the hissing.  
NOTE: A slight clockwise turn past the point where the hissing just stops will reduce wear and tear on  
regulators used heavily in rental or training situations.  
(5) Depress the lever assembly in the second stage five or six times to get the internal parts seated in their  
proper positions. Listen for any hissing. Adjust if necessary.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
(6) After setting the adjusting orifice, check the relationship between the diaphragm wear plate and the tip  
of the lever assembly. If you are reusing the same major parts of the regulator, this measurement will most  
likely be correct, and no adjustment will be needed. To check this relationship, temporarily install the diaphragm  
(Item 2). With the diaphragm properly seated along its edges, use the finger to tap the wear plate against the  
tip of the lever. If a slight gap between the wear plate and the lever tip is detected, the lever is too low. If no gap  
is felt, and no air begins hissing when the cover is installed the height of the lever is OK. If air does begin to  
hiss only when the cover is installed, the lever is too high.  
(7) If no adjustment to the lever height is needed, proceed to step (8). If adjustment either up or down on  
the lever is needed, use Sherwood's lever height adjusting tool p/n TL123. Install the lever in the slot of the  
tool. Refer to Sherwood's Tools, Repair Kits and Accessories Manual, page 8, for instructions on the use of  
the TL-123 tool.  
Holding the tool in one hand, with the tip of the lever toward the fingers, bend the lever carefully. Do not  
hold on to the case when making this adjustment, as this can result in the lever bending at the wrong area  
(near the lever support instead of at the mid-point of the lever). If necessary, bend the lever upward using the  
same holding method.  
Replace the diaphragm. Continue to test the gap between the lever and the diaphragm after each bending  
until the lever is in the correct position.  
TESTING  
INHALATION EFFORT:  
Check the inhalation effort of the second stage with a pan of water about five inches deep.  
(1) Slowly immerse the second stage with the inlet hose pointed straight up. Since this is an octopus  
regulator, no air should flow before the water floods into the mouthpiece. This type of setting assures that the  
regulator will not be prone to free flowing while it is out of the mouth during the dive.  
(2) If you use a water column or water manometer to check inhalation effort, it should not be less than  
1.5" - 2" w.c. at cracking. You can alter the inhalation effort within a certain range.,  
(3) You can increase the inhalation effort by turning the adjusting orifice (Item 18) clockwise. Discontinue  
clockwise adjusting when the lever assembly (Item 5) becomes loose against the lever support (Item 6).  
(4) You can decrease the inhalation effort by turning the adjusting orifice counter-clockwise. Discontinue  
counter-clockwise adjusting when air begins to hiss past the second stage orifice.  
EXHALATION EFFORT:  
If you do not use instruments to check the exhalation effort, the flow should feel smooth and unrestricted.  
If you use a water column, it should not exceed 1/2" w.c. at one atmosphere. Brand new exhaust valves  
will sometimes adhere slightly to the case, causing a slight increase in exhalation effort. This condition will  
disappear with use.  
LEAK TEST:  
(1) Disconnect the air supply. Purge the regulator of all positive air pressure.  
(2) Slowly immerse the second stage in a pan of water with the mouthpiece pointing straight up.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
(3) Immerse the regulator until the water is 1/4" to 1/8" from the lip of the mouthpiece.  
(4) Hold the regulator in this position for one minute and then slowly raise it out of the water.  
(5) Tip the regulator mouthpiece downward and watch the inside of the mouthpiece tube. If any water  
escapes from the mouthpiece tube, check for source of leakage.  
EXTERNAL AIR LEAKS:  
(1) Attach the regulator first stage to a tank short enough to totally submerge the first and second stage in  
your filling station cooling water.  
(2) With the tank valve still turned off, flood the second stage completely with water, and then position it  
mouthpiece up.  
(3) Turn the tank air valve on slowly and then watch for any leaks in the first or second stage (except for  
the normal flow of air from the one-way bleed valve on the first stage).  
(4) Repair any leaks.  
TROUBLESHOOTING  
POSSIBLE CAUSE  
RECOMMENDED ACTION  
HIGH INHALATION EFFORT AT DEPTH:  
1. Interstage pressure too low . . . . . . . . . . . . . . . .First stage should be putting out 130 psig minimum.  
2. Second stage improperly adjusted . . . . . . . . . .Repeat Steps 1 through 4 in the section of this manual  
entitled "Set-Up".  
FREE FLOWING:  
1. Intermediate pressure too high . . . . . . . . . . . . .First stage should be putting out 150 psig maximum.  
2. Damaged or worn L.P. poppet stem seat . . . . . .Replace seat (p/n 978-9S).  
3. Nicked or corroded orifice sealing . . . . . . . . . . .Dress the orifice with a polishing stick, or replace the  
orifice ice.  
4. Demand lever bent too high . . . . . . . . . . . . . . .Adjust or replace the lever.  
5. Weak spring in second stage . . . . . . . . . . . . . .Replace the spring.  
6. Second stage improperly adjusted . . . . . . . . . .Repeat Steps 1 through 4 in the section of this  
manual entitled "Set-Up".  
7. Parts in the second stage have been . . . . . . . .Allow the second stage to warm back up to room  
severely chilled due to repeated purging  
and have shrunk, allowing air to flow.  
temperature (this chilling will not occur in normal  
diving).  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
WET BREATHING:  
1. Improper clearing, or diver diving . . . . . . . . . . . . . .Instruct the diver on proper clearing head-technique.  
in total down position.  
2. Diaphragm improperly installed . . . . . . . . . . . . . . .Check position of diaphragm visually.  
3. Hole in the mouthpiece at tie area . . . . . . . . . . . . .Replace the mouthpiece.  
4. Hole in the diaphragm . . . . . . . . . . . . . . . . . . . . . .Replace the diaphragm.  
5. Damaged exhaust valve, or edges of the . . . . . . . .Replace exhaust valve.  
exhaust valve not firmly seated on the case.  
6. Crack in case . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Replace case.  
PARTS CLEANING RECOMMENDATIONS  
Regulators which see heavy use, particularly those used in salt water, often require extra effort to remove  
dirt and corrosion from the parts of the regulator. Some suggested cleaning solutions are listed at the end of  
this section, and there are probably many others being used successfully. Here are a few general suggestions  
we can make:  
First, don't expect your cleaning solution to do all the work in a matter of seconds. If the solution cleans  
extremely rapidly, it is probably too strong and may be etching the finish on the parts. Use a wooden or plastic  
stick or a soft bristle brush to help get rid of the thickest deposits. Take special care not to damage orifice seal-  
ing areas. Dress the orifice sealing areas with a fine grit polishing stick or pencil eraser after drying the parts.  
Immerse only those parts which really need cleaning. With Sherwood's Dry Air Bleed System, the interior of  
the first stage is always clean and dry, so the piston and spring should never need cleaning. Immersing the  
clean Sherwood piston in contaminated cleaning solution can plug the flow control element in the face of the  
piston, which could slow or stop the flow through the positive air purge system.  
Many of the solutions used for cleaning metal parts can damage the nitrile compounds found in O-rings. For  
this reason, remove all O-rings before placing parts in a cleaning bath.  
SOME EXAMPLES OF COMMONLY USED CLEANING SOLUTIONS  
SOLUTION  
COMMENTS  
Soapy water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Good for plastic and silicone parts.  
Vinegar and water . . . . . . . . . . . . . . . . . . . . . . . . . . .Ingredients easily available. Approx. 15 min.  
(equal part solution) . . . . . . . . . . . . . . . . . . . . . . . . . .cleaning time.  
1000 cc water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Fast-acting solution that must be made and used  
60 gr. sulfuric acid . . . . . . . . . . . . . . . . . . . . . . . . . . . .with care. Use gloves and safety glasses.  
60 gr. potassium dichromate  
Cleaning solutions recommended . . . . . . . . . . . . . . .The preferred choice. Check with the manufacturer  
by ultrasonic cleaner manufacturers  
for strengths and recommended uses for their  
cleaners.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
CUSTOMER MAINTENANCE & HANDLING TIPS  
How your customers treat their regulators will directly influence the unit's function and durability. Here are a  
few tips that you can pass on to your customers to help ensure the durability of their new Sherwood octopus:  
PRE-DIVE CHECKS:  
(1) Check the hoses and hose connections for cuts, abrasions or other signs of damage before mounting  
the regulator on the tank valve. Slide the hose protectors back to inspect the areas of the hose normally  
covered. Be sure all hose connections are tight.  
(2) Before turning on the tank air valve, check to make sure that the yoke nut or DIN connection is tight  
and the regulator body is aligned properly, with no kinks in the hoses.  
(3) Turn the tank valve on slowly and listen for leaks. If any leaks are found, replace or repair parts as  
recommended.  
(4) Never lift the tank/BCD assembly by the regulator or hoses.  
(5) Surface-test the regulator by breathing lightly through the mouthpiece. Depressing the purge button  
above the water's surface is not an appropriate method for testing the function of the regulator.  
POST-DIVE CARE:  
(1) After the dive, blow all water out of the dust cap with clean dry air and place the cap securely on the  
regulator inlet. On multiple tank dives, keep salt water out of the regulator inlet when changing tanks. Neglecting  
these simple procedures is the greatest cause of corrosion and wear in scuba regulators. When used properly,  
Sherwood's exclusive Dry Air Bleed System keeps all other water-borne contamination out of the first stage  
body.  
NOTE: A tiny stream of air bubbles escaping from a small black valve on the first stage indicates that the  
Dry Air Bleed System is working. The amount of air used is negligible (13 - 27 cc/min.). Check the system  
periodically, particularly after servicing, to ensure that there is some air escaping from the black one-way  
bleed valve. If no air is escaping from the valve when you apply air pressure to the first stage, have the  
regulator inspected.  
(2) With the dust cap securely in place, rinse the first and second stages in clean fresh water. DO NOT  
depress the purge button before or during rinsing since this may introduce water 'into the second stage and  
the low pressure hose. Shake or blow all excess water from the second stage and allow the entire regulator  
to air-dry before storing.  
(3) Store the regulator in a clean bag or storage box, away from sunlight, excessive heat and humidity.  
SCHEDULED MAINTENANCE:  
To keep the owner warranty in effect, your customers must have their regulators inspected and serviced  
annually (within 30 days before or after the anniversary of the date of purchase) by an authorized Sherwood  
Dealer. Failure to do so invalidates the warranty. Even with infrequent use, the regulator must be serviced  
annually to ensure proper performance and satisfy warranty requirements.  
Companion instructional VHS videotapes to this and other Sherwood repair manuals are available from  
your authorized Sherwood distributor at a nominal cost. Ask your Sherwood sales representative or authorized  
Sherwood distributor for details.  
NOTE: Part numbers and specifications are subject to change without notice. Changes will be announced  
by technical bulletins. You, the repair technician, should have ready access to these bulletins. Your authorized  
Sherwood distributor is your most current source of correct part numbers and information.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
MINIMUS (SR3108) AND SHADOW+ (SR3209)  
ITEM# CATALOG#  
DESCRIPTION  
14 . . . .3786-9W . . . . . . .Mouthpiece Tie  
15 . . . .3602-3 . . . . . . . . .Mouthpiece  
16 . . . .1-3108-7 . . . . . . .Orifice Housing (for Minimus  
version  
17 . . . .G01 OA . . . . . . . .O-ring (for adjustable orifice)  
18 . . . .43-4006-20 . . . . .Adjustable Orifice (no O-ring)  
19 . . . .G01 OA . . . . . . . .O-ring (for hose outlet end)  
1 . . . . .3108R-6 . . . . . . . .Cover (right hand version)  
1 . . . . .3108L-6 . . . . . . . .Cover (left hand & Shadow+  
version)  
2 . . . . .3108-13 . . . . . . . .Diaphragm (blue Tufel®)  
3 . . . . .J12CO4045B . . . .Screw (combination Phillips/  
square drive)  
4 . . . . .19-4006-17 . . . . .Washer  
20  
3809-50-36  
Hose Assembly with hose  
protector (36")  
5 . . . . .3108-3 . . . . . . . . .Lever  
6 . . . . .9-3108R-9 . . . . . .Lever Support  
(right hand version)  
21 . . . .3602-27 . . . . . . . .Hose Protector  
22 . . . .G011B . . . . . . . . .O-ring (hose inlet end)  
6 . . . . .9-3108L-9 . . . . . .Lever Support  
(left hand version & Shadow+)  
Note: The following parts are unique to the Shadow+.  
See Fig. 1  
23 . . . .1-3209-7 . . . . . . .Orifice Housing  
(for Shadow+ version)  
24 . . . .G01 5C . . . . . . . .O-ring (larger of the two for the  
swivel)  
25 . . . .G014C . . . . . . . . .O-ring (smaller of the two for the  
swivel)  
26 . . . .. 2-3209-12 . . . . .Swivel fitting  
27 . . . .3208-30-38 . . . . .Hose assembly with quick  
disconnect  
7 . . . . .19-3602-29 . . . . .Spring  
8 . . . . .9-3108-18 . . . . . .Stem (no seat insert installed)  
9 . . . . .978-9BN . . . . . . .Seat Insert (for stem)  
10 . . . .3801-8 . . . . . . . . .Exhaust Grill  
11 . . . .4006-15 . . . . . . . .Exhaust Valve  
12 . . . .3702-5 . . . . . . . . .Screw for Cover (4 required)  
13 . . . .3108R-5 . . . . . . . .Case (right hand version)  
13 . . . .3108L-5 . . . . . . . .Case (left hand & Shadow+  
version)  
THE HOUSING AND SWIVEL PARTS IN FIGURE  
1
ARE  
UNIQUE TO THE SR3209 SHADOW+. THEY REPLACE ITEM  
16, FOUND IN THE SR3108 MINIMUS.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6204 Goodrich Road  
Clarence Ctr, New York 14032  
Sherwood Scuba, the SS symbol, Oasis, Blizzard, Magnum, Brut and Wisdom  
are trademarks of Sherwood, Harsco Corporation Gas and Fluid Control Group.  
All other names are trademarks of their respective owners.  
© 2001 The Liberty Group  
Part Number S-MAN2007  
Printed in the U.S.A on recycled paper  
ALL PRODUCTS SUBJECT TO CHANGE WITHOUT NOTICE.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Camcorder VL A110U User Manual
Shure TV Antenna UAPF X1 User Manual
Sony Camera Accessories SPK THB User Manual
Sony Personal Computer PCV RX4 User Manual
SOYO Computer Hardware SY K7VEMPRO V10 User Manual
Spalding Fitness Equipment 211999B User Manual
Sunbeam Convection Oven HG5400 User Manual
Sybase Server 1242 User Manual
Tandy Cordless Telephone ET 539 User Manual
Targus Computer Hardware USB Number Pad User Manual