OWNER’S MANUAL
®
BATTERY CHARGER
60/20/2 Amp
Fully Automatic
275/125 AMP
ENGINE STARTER
With Battery Tester and
GFCI Outlets
Model No.
200.71234
CAUTION:
Read all Safety Rules and Operating Instructions,
and follow them with each use of this product.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
00-99-000539/0206
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
– SAVE THESE INSTRUCTIONS –
To reduce the risk of explosion, explosive gases, or injury while
using your battery charger, follow the precautions listed below:
WARNING
• Read all instructions and cautions printed on the
battery charger, battery, and vehicle or equipment
using battery.
• Do not disassemble charger. Take it to a
qualified service professional if service or repair
is required. Incorrect assembly may result in fire
or electrical shock.
• Use charger only on lead-acid type rechargeable
batteries, such as those used in cars, trucks,
tractors, airplanes, vans, RV’s, trolling motors, etc.
This charger is not intended to supply power to a
low voltage electrical system other than in an
automotive application.
• To reduce risk of electrical shock, unplug the
charger from the outlet before attempting any
maintenance or cleaning.
• Always charge battery in a well ventilated area.
• Use only attachments recommended or sold by
manufacturer. The use of attachments not recom-
mended by the manufacturer may result in fire,
electric shock, or injury.
• Wear complete eye and clothing protection when
working with lead-acid batteries.
Help us help you
Remember:
• Be sure that someone is within range of your voice
to come to your aid if needed while you work with or
are near a lead-acid battery.
• Place charger as far away from battery being
charged as the charger cables will permit.
• Do not expose charger to rain or snow.
• Have plenty of fresh water and soap nearby for
use in case battery acid contacts your eyes, skin, or
clothing. If this happens, wash immediately with
soap and water. Then get medical attention.
• Never charge a frozen battery. If battery fluid
(electrolyte) becomes frozen, bring battery into a
warm area to thaw before you begin charging.
• Never allow battery acid to drip on charger when
reading specific gravity or filling battery.
• Avoid touching your eyes while working with a
battery. Acid particles (corrosion) may get into your
eyes. If this occurs, flush eyes immediately with
running cold water for at least 10 minutes. Then
immediately get medical attention.
• Never set a battery on top of the charger.
• Never place charger directly above battery being
charged. The gases from the battery will corrode
and damage the charger.
• Remove all personal metal items from your body,
such as rings, bracelets, necklaces, and watches
while working with a lead-acid battery. A battery can
produce a short circuit current high enough to weld a
ring (or the like) to metal, causing a severe burn.
• Never use charger for charging dry-cell batteries
that are commonly used with home appliances.
These batteries may burst and cause personal
injury.
• Take care not to drop any metal tool or metal object
onto the battery. This may spark or short circuit the
battery or another electrical device that may cause
an explosion.
• Never touch the battery clamps together when the
charger is energized.
• Never operate charger if it has received a hard blow,
been dropped, or otherwise damaged. Take it to a
qualified professional for inspection and repair.
• Always operate your battery charger in an open,
well ventilated area.
• Be sure to position the charger power cord to
prevent it from being stepped on, tripped over, or
damaged.
• Never smoke or allow a spark or flame in the vicinity
of the battery or engine. Batteries generate explo-
sive gases.
• Never pull out the plug by the cord when unplugging
the charger. Pulling on the cord may cause damage
to the cord or the plug.
• Neutralize any acid spills thoroughly with baking
soda before attempting to clean up.
• WARNING: Handling the cord on this product or
cords associated with accessories sold with this
product, may expose you to lead, a chemical known
to the State of California to cause cancer and birth
defects or other reproductive harm. Wash hands
after handling.
• Do not operate the charger if it has a damaged
power cord or plug. Have the cord replaced.
Personal Safety Precautions
For your own personal safety, please follow the
following precautions:
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts
This section shows an illustration of your battery charger. Use it to become familiar with where all the parts are
located, and what they look like.
17
6
Replacement Parts List DieHard 71234
ITEM
1
PART NUMBER
3799004100
0499000050
0499000053
2299001465
0899002622
3599000262
0099000587
3999000108
3899001165
3899001164
90026177
DESCRIPTION
1
Plastic Top
2
5
2
Rocker Switch SPST
Rocker Switch DPDT
3
3
4
Control Board Assembly
5
10
Faceplate
Handle
4
7
6
7
Receptacle, GFCI, 15A
Circuit Breaker
11
8
9
Positive (RED) Cable w/clamps
9
8
10
11
12
13
14
15
16
17
18
19
20
Negative (BLACK) Cable w/clamps
Power Cord
12
13
2299001467
93026585
Power Board/Heatsink Assembly
Transformer
15
Fan Motor
0099000604
2299001078
0099000120
0399000018
1199005112
0099000066
0099000539
19
18
14
Hardware Kit
Wheel
15
Handle Grip
Mounting Foot
Axle
16
15
Owner's Manual
Wiring Diagram
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Before Using Your Battery Charger
It is important to prepare your charger for use. This section will tell you how to assemble the charger, ground
and connect the power cord, and prepare to charge a battery.
Assembling your charger
It is important to fully assemble your charger before use.
Follow these instructions for easy assembly.
PARTS:
TOOLS NEEDED:
Two, 10-32 thread cutting
screws
3/8" wrench
(for mounting foot)
Two, 1/4-20 thread cutting
screws
5/16" wrench
(for wheels)
Two wheels
Hammer
One axle
Phillips screwdriver
Two axle caps
Two axle brackets
One handle
One handle grip
One mounting foot
Attach Foot:
Remove charger from packing materials and place
charger on its side. Attach mounting foot and secure
with the two, 1/4-20 thread cutting screws provided.
Axle Assembly:
Hold axle upright on floor or work surface. Then, using
a hammer, tap one of the axle caps onto
the top end of the axle. Be sure to tap the hub on
straight. Slide both wheels onto the axle with the
hubs facing inward. Tap the other axle cap onto the
opposite end of the axle and place the axle assembly
onto the bottom of the charger.
continued on next page
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Axle Assembly (continued):
Place the charger on its side. Place one end of each
bracket into slot, then place the axle assembly under
each bracket. Fasten the other side of each bracket
using the two, 10-32 thread cutting screws provided.
Handle:
Turn the charger right side up onto its foot and wheels.
Remove the two top screws from each side of the
charger. Slide handle grip over handle tubing. Align the
handle so the screw holes are aligned with the screw
holes on each side of the wheel charger. Attach
handle using the same screws.
Plugging it in
WARNING
Electrical Shock Hazard
Be sure that power cord fits properly into outlet.
If not, have a qualified technician install a proper
outlet. Never alter the AC cord or plug provided.
Improper connection can result in electrical shock.
Your charger should be grounded to reduce the
risk of electrical shock.
A 3-Prong Grounded Wall Outlet
Your charger is equipped with an electrical cord that
has an equipment grounding conductor and a ground-
ing plug designed to be used on a 120V circuit. The
plug must be plugged into an outlet that has been
properly installed and grounded in accordance with all
local codes and ordinances.
This Battery Charger includes GFCI protected outlets.
Proper grounding is required for correct GFCI opera-
tion.
WARNING
DO NOT exceed 15 Amps on GFCI Outlets. If
using Battery Charger DO NOT exceed 3 Amps.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the GFCI Outlet
• This charger includes two – GFCI (Ground Fault
Circuit Interrupter) outlets located on its back. The
purpose of a GFCI outlet is to quickly stop the flow of
electricity in the event a ground fault occurs on the
device plugged into the battery charger’s GFCI outlet.
Ground fault circuit interrupters (GFCI) can help
prevent electrical shock or electrocution.
4. Push the “Reset” button, again. The light or other
product should go “ON” again.
NOTE: If the light or other product remains “ON” when
the “Test” button is pushed, the GFCI is not working
properly and should not be used. Call Customer
Service at 1-800-SEARS-64 (1-800-732-7764).
• The power cord must be plugged into a 3-prong
grounded 120V AC wall outlet for the GFCI opera-
tion to function. Ground fault circuit interrupters
(GFCI) can help prevent electrical shock or electro-
cution.
• The GFCI outlets provide auxiliary power to 120V
devices that require less than 15 amps.
The GFCI must be tested before each use. To test:
1. Push the “Reset” button located on the GFCI
receptacle, first to assure normal GFCI operation.
• If you are charging a battery, the GFCI outlet should
be limited to 3 amps of current draw until the charg-
ing functions are complete.
2. Plug a nightlight (with an “ON/OFF” switch) or
other product (such as a lamp) into the GFCI
receptacle and turn the
• The GFCI outlet should not be used while the
charger is in the ENGINE START mode.
GFCI OUTLET
product “ON.”
3. Push the “Test” button
located on the GFCI recep-
tacle. The nightlight or other
product should go “OFF.”
• If using both GFCI outlets at the same time, the
amperage cannot exceed 15 amps of both devices
combined.
RESET
TEST
Button
Button
Using an extension cord
The use of an extension cord is not recommended. If
you must use an extension cord, please make sure
that you follow these guidelines:
• Use the recommended minimum AWG (American
Wire Gauge) to be sure that wire size is large
enough for the rating of the charger.
• Make sure the pins on the plug of the extension cord
are the same number, size, and shape as those of
the plug on the charger.
MINIMUM RECOMMENDED EXTENSION CORD
Length of Cord, in Feet
25
50
100 150
• Use only 3-conductor (grounded) extension cord
when necessary.
AWG* Size of Cord
14
12
10
8
• Check that the extension cord is properly wired and
in good electrical condition.
*AWG=American Wire Gauge
Preparing your battery to be charged
It is important that you read and follow these guide-
lines while you are preparing to charge your battery.
cell caps while charging, and recommended rates
of charge.
• Wear safety glasses. See additional “Personal
Safety Precautions” on page 2.
• Make sure that you have a 12 volt or 6 volt lead-acid
battery. Set the volt/amp selector switch to match
the voltage rating of the battery to be charged.
• Be sure that the area around the battery is well
ventilated while it is being charged. If ventilation is
poor, any gases emitted from the battery can be
manually blown away by using a piece of cardboard
or other non-metallic material as a fan.
• Clean the battery terminals. Be careful to keep
corrosion from getting in or around your eyes or on
your hands.
• If you have a battery with removable cell caps, if
required, add distilled water to each cell until the
battery acid reaches the level recommended by the
manufacturer. This will help purge excessive gases
from the cells. Be careful not to overfill. If you have a
sealed battery without cell caps, no action is neces-
sary. Continue to the next step listed below.
• If it is necessary to remove the battery from the
vehicle to charge it, always remove the grounded
terminal from the battery first. A spark may be
caused if all accessories in the vehicle are not
completely turned off.
NOTE: A marine battery installed in a boat must be
removed and charged on shore.
• Take time to read all battery manufacturer’s specific
precautions, such as removing or not removing
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Your Battery Charger
For best results from your battery charger, learn to use it properly. This section tells how to set the controls,
charge a battery in or out of the vehicle, use the ENGINE START feature and test the battery.
Setting the controls
All the controls for your charger are located on the
front. Follow these instructions to obtain the accurate
charge level for your battery.
OFF
6V
ON
POWER
POWER ON/OFF SWITCH
Make sure your charger is OFF when connecting or
disconnecting your charger from the vehicle and power
source. Turn your charger ON only when it is con-
nected to the vehicle and plugged into a 3-prong
grounded wall outlet.
12V
BATTERY
BATTERY VOLTAGE SELECT
When charging, testing or starting 12 volt systems,
select 12 VOLT. Select 6 VOLT when charging,
testing or starting 6 volt systems.
TOUCH-PAD CONTROLS
• MANUAL: When first turned on, the charger will be
in the Manual mode - there will be no need to select
MANUAL. Select a charge rate and time. The
charger will start charging after a short delay. It will
stop charging only when the selected time or
maximum time is up. For this reason, it is IMPOR-
TANT to check the charger frequently to avoid
overcharging the battery. While charging, the
METER will show battery voltage. To see how much
of the selected charge time is remaining, touch the
TIME pad. The METER will show the time and, after
a short delay, return to showing voltage. To see the
amount of amps being drawn by the battery, touch
the VOLTS/AMPS pad.
With your charger connected to the vehicle and power
source, the battery voltage (6 or 12 volt) selected, and
the power turned ON, select either AUTOMATIC or
MANUAL charge and the rate at which you want to
charge your battery (2, 20, or 60 amp).
• AUTO (Automatic): When first turned ON, the
charger will be in the Manual mode. Touch the
AUTO pad and either the 2, 20, or 60 AMP Charge
Rate Selector pad. Charging will start after a short
delay. It will stop when the battery is fully charged.
While charging, the METER will show battery
voltage. Touch the VOLTS/AMPS pad to see the
amount of amps being drawn by the battery.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
• TIME: To select a charging time, you must be in the
MANUAL mode and have selected a charge rate.
Touch the TIME pad until the desired time shows on
the meter. The following chart shows the amount of
time available for each charge rate and the amount
of time, in hours, added for each touch of the TIME
pad.
1 HR
2 HR
3 HR
PRESS
ONE TIME
PRESS
TWO TIMES
PRESS
THREE TIMES
RATE
2 Amps
20 Amps
60 Amps
TOUCH "TIME" PAD TO ADD INCREMENTS
Maximum
Time
18 Hours
10 Hours
5 Hours
Increment
Settings
1 Hour
1 Hour
1/2 Hour
If you do not set a time, the charger will run for the
maximum time. After selecting the charge rate and
proper time, the charger will start charging after a
short delay. To see how much time remains during
the charging process, touch the TIME pad.
• RESET: To stop charging or to change settings
once charging has begun, touch the RESET pad.
Then proceed as if you’ve just turned on the
charger.
OFF
6V
ON
SWITCH
• VOLT/AMP: When the charger is turned on the
METER will display battery voltage. Touch the
VOLTS/AMPS pad to display the charge rate in
amps.
POWER
12V
SWITCH
• TESTER: To check the battery’s state-of-charge
during charging, touch the RESET pad and then the
TESTER pad. The METER will show the voltage of
the battery. Wait about 5 minutes before taking a
reading. To continue charging, proceed as if you’ve
just turned the charger ON.
BATTERY
• ENGINE START: To use the starter feature to help
crank the engine of your vehicle, touch RESET,
MANUAL, and ENGINE START - in that order. Wait
for the display to show RDY. The ENGINE START
feature will deliver 275 amps to help crank a 12-volt
system or 125 amps to help crank a 6-volt system.
Crank the engine for no more than 5 seconds. If it
does not start, wait three minutes before cranking
again. During extremely cold weather, or if the
battery is severely exhausted, charge the battery for
about 5 minutes in the 60 AMP setting before
cranking the engine.
CAUTION: DO NOT try to crank an engine
without a battery installed. You may damage the
vehicle’s electrical system.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
• METER: Besides showing amps, volts, and time, the
meter displays information:
—A—
—V—
MAN
Charge Rate in amps
Voltage
Charger is in Manual mode
Charger is in Automatic mode
AUTO
RDY
Charger is ready for cranking
(Engine Start)
WAIT
Wait until the charger is ready before
cranking again
FULL
OFF
Battery is charged (Automatic mode)
Time has expired (Manual or
Timer mode)
HR
Hour(s)
CHK BATT
There is a problem with the battery or
connections
OL
Too high a charging rate; lower rate
to continue
Charging Your Battery
NOTE: A marine (boat) boat battery must be removed
and charged on shore. To charge it on board requires
equipment specially designed for marine use.
chassis or engine block, away from the battery. Do
not connect clamp to carburetor, fuel lines or
sheet metal parts.
IMPORTANT: Wear safety glasses and face away
from the battery while making connections.
6. Twist or rock clamps back and forth to make a
solid connection. This will help make better
contact and help keep them from slipping off and
causing sparks.
7. Make sure the POWER switch is set to the OFF
position. Next plug the power cord into a 3-prong
grounded 120V AC electrical wall outlet.
Charging your battery in the vehicle:
1. Arrange the power cord and charging leads
carefully in order to avoid damage that could be
caused by the hood, door, or moving engine parts.
2. Keep hands, hair, clothing and jewelry clear of the
fan blades, belts, pulleys, and other parts that can
cause injury.
3. Check the polarity of the battery posts using the
identification marks on the battery case: POSI-
TIVE (POS, P, +) and NEGATIVE (NEG, N, -).
4. Identify which battery post is grounded or con-
nected to the chassis. THE NEGATIVE POST IS
NORMALLY THE ONE THAT IS GROUNDED.
5. To charge a negative grounded post system:
Connect the red (POSITIVE) charger clamp to the
ungrounded POSITIVE (POS, P, +) post of the
battery. Next, connect the black (NEGATIVE)
clamp to an unpainted, heavy metal part of the
chassis or engine block, away from the battery. Do
not connect clamp to carburetor, fuel lines, or
sheet metal parts.
To charge a positive grounded post system:
Connect the black (NEGATIVE) charger clamp to
the ungrounded NEGATIVE (NEG, N, -) post of
the battery. Then connect the red (POSITIVE)
clamp to an unpainted, heavy metal part of the
NEGATIVE GROUNDED SYSTEM
9
Download from Www.Somanuals.com. All Manuals Search And Download.
8. For automatic charging, touch AUTO then a
charge-rate pad 2, 20, or 60 Amps. The charging
will stop when the battery is fully charged.
9. For manual charging, touch a charge rate pad
then select a charge time up to 18 hours. If more
than 18 hours of charging time is needed, reset
the time when the original time runs out. Refer to
the Time Chart in the “Setting the Controls” on
page 8 of “Using your Battery Charger.”
10. In the MANUAL mode, at the 60-Amp charging
rate, the METER will show a charge rate of 25 to
30 amps or less when the battery is at or near full
charge. At the 20-Amp charging rate, the METER
will show a charge rate of 8 to 10 amps or less
when the battery is at or near full charge.
At the 2-Amp charging rate, the METER will
show a charge rate of .75 to 1 amp when the
battery is at or near full charge.
6. Make sure the POWER switch is set to the OFF
position. Next plug the power cord into a grounded
AC outlet.
7. For automatic charging, touch AUTO then a
charge-rate pad. The charger will quit when the
battery is fully charged.
8. For manual charging touch a charge rate pad then
select a charge time, up to 18 hours. If more than
18 hours of charging time is needed, reset the
time when the original time runs out. Refer to the
Time Chart in the “Setting the Controls” on page 8
of “Using Your Battery Charger Time Chart.”
9. In the MANUAL mode at the 60-Amp charging
rate, the METER will show a charge rate of 25 to
30 amps or less when the battery is at or near full
charge. At the 20-Amp charging rate, the METER
will show a charge rate of 8 to 10 amps or less
when the battery is at or near full charge. At the 2-
Amp charging rate, the METER will show a charge
rate of .75 to 1 amp when the battery is at or near
full charge.
11. TO AVOID OVERCHARGING in the Manual
mode, monitor the METER frequently.
12. When the battery is fully charged, turn the
POWER switch to the OFF position and unplug
the charger power cord from the wall outlet.
13. Facing away from the battery, remove the charger
clamps in this order: (1) from the chassis connec-
tion and, (2) from the battery post or terminal.
14. Clean and store the battery charger in a dry
location.
10. TO AVOID OVERCHARGING in the Manual
Mode, monitor the METER frequently.
11. When the battery is fully charged, turn the
POWER switch to the OFF position and unplug
the charger power cord from the wall outlet.
12. Stand away from battery and remove the charger
clamps from the NEGATIVE end of the cable first,
then from the POSITIVE post.
13. Clean and store the battery charger in a dry
location.
Charging your battery outside the vehicle:
NOTE: A marine (boat) battery must be removed and
charged on shore. To charge it on board requires
equipment specially designed for marine use.
1. Remove the battery from vehicle, making sure to
disconnect grounded terminal first with all
accessories and lights turned off in the vehicle.
2. Check the polarity of the battery posts as indicated
on the battery case: POSITIVE (POS, P, +) and
NEGATIVE (NEG, N, -).
NOTE: On top-post batteries, the positive battery
terminal usually has a larger diameter post than the
negative one.
3. Connect the red (POSITIVE) charger clamp to the
POSITIVE post of the battery. Be sure to rock the
clip back and forth to make a solid connection.
4. Attach at least a 6-gauge (AWG) insulated battery
cable of at least 24-inches in length to the
NEGATIVE battery post. This cable will provide a
safer connection because arcing and sparking will
occur away from the battery. (The battery cable is
not provided with the charger, but may be
purchased at most automotive accessory outlets.)
5. Standing as far away from the battery as possible,
connect the black (NEGATIVE) lead of the charger
to the free end of the cable. Rock the clamp to
make a solid connection. IMPORTANT: Wear
safety glasses and face away from the battery while
making this final connection.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Calculating charge times
The Chart Method
• Marine, or deep-cycle batteries are usually rated in
Reserve Capacity (RC).
Use the following table to more accurately determine
the time it will take to bring a battery to full charge.
First, identify where your battery fits into the chart.
• NR means that the charger setting is NOT RECOM-
MENDED.
• Small batteries — motorcycles, garden tractors, etc.
— are usually rated in Ampere Hours (AH). For
example: 6, 12, 32 AH etc.
Find your battery’s rating on the chart below and note
the charge time given for each charger setting. The
times given are for batteries with a 50-percent charge
prior to recharging. Add more time for severely dis-
charged batteries.
• Batteries in cars and smaller trucks are usually rated
in Reserve Capacity (RC), Cold-Cranking Amps
(CCA), or both.
CHARGE RATE/CHARGING TIME - HOURS
BATTERY SIZE/RATING
2 AMP
2 - 4
4 - 10
11 - 14
14 - 18
18 - 35
18
20 AMP
NR
60 AMP
NR
Motorcycle, garden
tractor, etc.
6 - 12 AH
12 - 32 AH
40 - 60 RC
60 - 85 RC
85 -190 RC
80 RC
SMALL
BATTERIES
NR
NR
200 - 315 CCA
315 - 550 CCA
550 - 1000 CCA
60 - 90 min.
90 - 120 min.
2 - 3.5 hrs.
105 min.
2 hrs., 45 min.
3.0 hrs.
20 - 30 min.
30 - 40 min.
45 - 60 min.
NR
CAR/TRUCKS
MARINE/DEEP CYCLE
140 RC
27
NR
30
NR
160 RC
33
3.5 hrs.
NR
180 RC
To calculate time needed for a charge:
The Hydrometer or Electronic Method
To find the time needed to fully charge your battery,
determine the battery’s charge level with a hydrometer
or electronic Percent-of-Charge Tester. The following
table will help you convert hydrometer readings to
percent of charge values.
• Find the percent of charge needed. (A battery at 50
percent charge that will be charged to 100 percent
needs another 50 percent (.50).
• Multiply the Amp Hour rating by the charge needed
(.50) and divide by the charger setting (2, 20 or 60
amps).
• Multiply the result by 1.25 and you’ll have the time
needed, in hours, to bring the battery to full charge.
SPECIFIC
GRAVITY OF CHARGE
PERCENT
PERCENT OF
CHARGE NEEDED
• Add one additional hour for a deep-cycle battery.
1.265
1.225
1.155
1.120
100%
75%
25%
0%
0%
25%
75%
100%
Example:
Amp Hour Rating x % of charge needed x 1.25 = hours
Charger Setting
of
charge
100 (AH Rating) x .50 (charge needed) x 1.25 = 3.125
20 (Charger Setting)
hours
When you know the percent of charge and the Amp
Hour (AH) rating of your battery, you can calculate the
approximate time needed to bring your battery to a full
charge.
100 x .50 = 2.5 x 1.25 = 3.125
20
To convert Reserve Capacity to Amp Hours, divide
Reserve Capacity by 2, and add 16:
You would need to charge your 100-Ampere Hour
Battery for a little more than 3 hours at the 20-Amp
charge rate using the above example.
Amp Hours = Reserve Capacity + 16
2
NOTE: The Reserve Capacity can be obtained from
the battery specification sheet or the owner’s manual.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the engine start feature
Your battery charger can be used to jump-start your
car if the battery is low. Follow these instructions when
using the ENGINE START feature.
1. Set the POWER switch to the OFF position. Then
follow the instructions for connecting the charger
to the battery and power source in the section
“Charging a battery in the vehicle.”
7. If the engine still does not start, charge the battery
for five more minutes before cranking it again for
five seconds.
8. After the engine starts, unplug the charger power
cord from the wall outlet. Then move the POWER
switch to the OFF position before disconnecting
from the battery.
2. Set the BATTERY switch to 6V or 12V to match
Important:
the battery’s voltage.
Do not try to start the engine without a battery in it.
You could cause damage to the electrical system.
3. Set the POWER switch to the ON position. The
METER display will show MAN (manual mode).
4. Touch RESET, MANUAL and ENGINE START
pads in that order. Wait for the display to show
RDY. The charger is now ready to have the engine
cranked.
5. Crank the engine for no more than 5 seconds. If
it does not start, wait 3 minutes. (The display will
show WAIT during this time and RDY when the
time is up.)
If the engine does turn over, but never starts up, there
is not a problem with the starting system, there is a
problem somewhere else with the vehicle.
STOP cranking the engine until the other problem has
been diagnosed and corrected.
NOTE: The GFCI outlet should not be used while the
Charger is in the Engine Start Mode.
6. During extremely cold weather, or if the battery is
severely exhausted, charge the battery for about 5
minutes in 60 amp setting before cranking the
engine.
Maintenance and care
A minimal amount of care can keep your battery
charger working properly for years.
1. Clean the clamps each time you are finished
charging. Wipe off any battery fluid that may have
come in contact with the clamps to prevent
corrosion.
2. Coil the input and output cords neatly when storing
the charger. The cords can be wrapped around
the handle of the charger. This will help prevent
accidental damage to the cords and charger.
3. Occasional cleaning of the case with a soft cloth
will keep the finish shiny and help prevent corro-
sion.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Performance problems often result from little things that you can fix yourself. Please read through this table for a
possible solution if a problem occurs.
PROBLEM
POSSIBLE CAUSE
Clamps are not making a Check for poor connections at battery and frame. Make
good connection. sure connecting points are clean.
AC cord and/or extension Check power cord and extension cord for loose fitting
SOLUTION/REASONS
No reading on the
Display.
No reading on
meter. Charger fan
not working.
or
cord is loose.
plug.
No power at receptacle.
Shorted battery clamps.
Check for open fuse or circuit breaker supplying AC outlet.
In MANUAL Mode,
circuit breaker in
charger cycles on and Shorted battery.
off with a clicking
Circuit breaker cycles when current draw is too high.
Check for shorted cables and replace if needed.
Have a Sears Service Center test the battery.
sound.
Charger leads reversed.
Correct connections.
Charger set at the START Correct touch-pad settings.
position.
Short start cycle when Drawing more than 275
Crank time varies with the amount of current drawn. If
cranking draws more than 275 amps, crank time may be
less than 5 seconds.
cranking engine.
amps. (12V)
Failure to wait for 3
minutes (180 seconds)
between cranks.
Wait until the METER displays RDY.
Meter reads less
Extension cord too long.
Use shorter or heavier gauge extension cord.
than selected charge
rate when charging
a discharged battery.
Weak cell or sulfated
plate in battery.
Sulfated battery will eventually take a normal charge if
left connected. If the battery will not take a charge, have
it tested by a Sears Service Center.
Battery is only partially
discharged.
Continue to charge battery.
Charger makes a loud Transformer laminations
Continue charging. Buzz is not abnormal.
buzz or hum.
vibrate (buzz).
METER reading stays
high.
Battery severely
discharged.
Continue charging battery for two more hours. If
problem continues, call Sears Service at 1-800-SEARS-64.
Wrong battery voltage
selected.
Make sure BATTERY Voltage Select switch is in proper
6 or 12 volt position.
A 120V device plugged The GFCI has “tripped”.
into the GFCI outlet
will not operate.
Reset the GFCI outlet by pressing the “RESET” button
on the outlet face. See complete test procedure on page
6 for details.
The charger’s AC power
Make sure the charger’s power cord or extension cord is
or extension cord is loose. connected to the AC wall outlet.
Devices exceed 15 amps
of the battery charger.
Check for open (blown) fuse or circuit breaker supplying
AC wall outlet.
If the above solutions do not eliminate the problem...
call toll-free from anywhere in the U.S.A.
1-800-SEARS-64
(1-800-732-7764)
7 AM to 4:30 PM Central Time Monday through Friday
13
Download from Www.Somanuals.com. All Manuals Search And Download.
For information about troubleshooting, call toll-free from anywhere in the
U.S.A. 7 am to 4:30 pm Central Time Monday through Friday.
1-800-SEARS-64 (1-800-732-7764).
14
Download from Www.Somanuals.com. All Manuals Search And Download.
|