Renesas Computer Hardware H8S 2214 Series User Guide

H8S/2214 Series  
TBP-112  
User System Interface Cable  
(HS2214ECB61H)  
for E6000 Emulator  
User’s Manual  
HS2214ECB61HE(C)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preface  
Thank you for purchasing this user system interface cable (HS2214ECB61H) for the Renesas’s  
original microcomputer H8S/2214series.  
The HS2214ECB61H is a user system interface cable that connects an H8S/2214 series E6000  
emulator (HS2214EPI61H; hereinafter referred to as the emulator) to the IC socket for a TBP-112  
package for the H8S/2214 series MCU on the user system.  
i
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
ii  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 1 Configuration  
CAUTION  
Use an CSPACK112A1110H01 socket (socket  
(manufactured by Tokyo Eletech Corporation) for the  
TBP-112 package IC socket on the user system.  
Figure 1 shows the configuration of the HS2214ECB61H user system interface cable for the  
TBP-112 package.  
To emulator station  
Cable body  
Screws (M1.6 x 8 mm)  
(for fastening cable head)  
Cable head  
Spacer  
IC socket  
Cover  
User system  
Figure 1 HS2214ECB61H User System Interface Cable  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Table 1 lists the HS2214ECB61H components. Please make sure you have all of these components  
when unpacking.  
Table 1  
HS2214ECB61H Components  
No. Component  
Quantity  
Remarks  
1
2
3
4
5
6
Cable body  
Cable head  
IC socket  
1
1
1
1
1
4
Includes flat cable  
For the TBP-112 package  
Spacer  
For installing an TBP-112 packaged MCU  
For installing an TBP-112 packaged MCU  
Cover  
Screws (M1.6 x 8 mm)  
For fastening cable head and for installing an  
TBP-112 packaged MCU  
7
8
Driver  
1
1
Dedicated screwdriver to fasten the screws.  
Documentation  
User’s manual for HS2214ECB61H (this manual)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 2 Connection Procedures  
2.1  
Connecting User System Interface Cable to Emulator Station  
WARNING  
Observe the precautions listed below. Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in  
PERSONAL INJURY. The USER PROGRAM will be  
LOST.  
1. Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are  
correctly aligned.  
2. The user system interface cable dedicated to the  
emulator must be used.  
To connect the cable body to the emulator station, follow the instructions below.  
1. Make sure the user system and emulator station are turned off.  
CAUTION  
When connecting or removing the user system interface  
cable, apply force only in the direction suitable for  
connection or removal, while making sure not to bend or  
twist the cable or connectors. Otherwise, the connectors  
will be damaged.  
2. After making sure the direction of the cable body connector is correct, firmly insert the cable  
body connector into the emulator station socket (figure 2).  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 2 Connecting User System Interface Cable to Emulator Station  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2  
Connecting User System Interface Cable to User System  
WARNING  
Always switch OFF the user system and the emulator  
product before the USER SYSTEM INTERFACE CABLE  
is connected to or removed from any part. Before  
connecting, make sure that pin 1 on both sides are correctly  
aligned. Failure to do so will result in a FIRE HAZARD and  
will damage the user system and the emulator product or  
will result in PERSONAL INJURY. The USER PROGRAM will  
be LOST.  
To connect the cable head to the user system, follow the instructions below.  
2.2.1 Soldering the IC Socket  
Install the socket for TBP-112-packaged ICs on the user system.  
(1) Gently apply solder to the BGA pads of the user system. Be careful to keep the thickness of  
the solder within 100 to 150 µm. Too much solder will cause short-circuiting of the pins.  
(2) The IC socket is vacuum-packed to avoid oxidization of the surfaces of the solder balls. It is  
thus recommended that the IC socket be installed on the user system if you don’s install the  
socket immediately after the package it comes in is opened. After the package’s seal has been  
broken, store the socket in a desiccator. Do not touch the solder balls. If they are touched,  
solder may not adhere to the solder surface.  
The IC socket is covered by a protective cover. Socket and cover are fastened together by  
four screws before the whole is vacuum packed to prevent bending of the IC socket’s pins.  
To avoid the scattering (dispersal) of flux from other components to the IC socket, keep the  
protective cover on the IC socket until solder reflow has been completed.  
(3) Install the provided guide pins into the holes for the guide pins on the user system. Check  
that the pads are correctly aligned with the IC socket.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
(4) Notes on soldering the IC socket  
a) The IC socket is larger than the actual IC package; therefore, refer to figure 7 for the  
installation of other components.  
b) Do not install components that occupy large volume close to the IC socket. Such  
components will prevent the convective flow of heat during reflow.  
c) Since the IC socket has a greater volume than the IC package, it is recommended that the  
temperature profile under the conditions used in installation be measured by attaching a  
temperature sensor to the back side of the IC socket.  
d) Under the reflow conditions for soldering the IC socket, specify the actual heating to  
more than 210°C for 30 to 60 seconds.  
Recommended Reflow Conditions  
Surface temperature of IC-socket connector  
Preheating: 150 to 180°C for 180 seconds  
Actual heating: To more than 210°C, for 30 to 60  
seconds  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
CAUTION  
1. Never dip the IC socket in flux or use wash to clean the IC  
socket. This is because flux may remain inside the IC  
socket due to the IC socket’s structure. When using the  
IC socket with other DIP products, never clean the other  
DIP products with flux because the flux may enter the  
connector through the guide pins of the IC socket.  
2. When an IC socket with guide pins is soldered to the  
user system, about 1.4 mm of the guide pins will stick out  
(when the user-system board is 1.6 mm thick). When a  
load is applied to the guide pins from the back of the  
user-system board, stress will be applied to the soldered  
part of the IC socket, and this may destroy the  
connectors. Do not apply any load to the guide pins after  
the IC socket has been soldered on the user system.  
3. When an IC socket with no guide pins is soldered to the  
user system, the soldered part will crack if stress is  
applied to the IC socket. Therefore, always apply  
adhesive to the connector and the user system so that  
there is a firm connection between them.  
4. When the IC socket has guide pins, it is recommended  
that epoxy resin adhesive or solder be applied to the  
guide pins at the back of the user system to make sure  
that no stress is applied to the soldered part  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.2  
Inserting Cable Head  
CAUTION  
Check the location of pin 1 before inserting.  
Align pin 1 on the IC socket for an TBP-112 package on the user system with pin 1 on the user  
system interface cable head, and insert the user system interface cable head into the IC socket on the  
user system, as shown in figure 3.  
Figure 3 Connecting User System Interface Cable to User System  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.2.3  
Fastening Cable Head  
CAUTION  
1. Use the screwdriver whose head matches the screw  
head.  
2. The tightening torque must be 0.054 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
3. If the emulator does not operate correctly, cracks might  
have occurred in the solder.  
The user system interface cable (HS2214ECB61H) head and the IC socket for the TBP-112 package  
on the user system have no pin dedicated for alignment. Use the follow procedure to fasten the  
cable head.  
1. Insert two screws (M1.6 x 8 mm) to and , and screw it a little so that holes at -' and -'  
match, respectively.  
2
3
1
4
2
3
1
4
Figure 4 Fastening Cable Head Procedure (1)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2. Next, fasten screws to and a little, so that four screw holes are aligned. Then, each screw  
should be tightened a little at a time, alternating between screws on opposing corners.  
2
4
Figure 5 Fastening Cable Head Procedure (2)  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.4  
Fastening Cable Body  
Connect the cable body to the cable head.  
Figure 6 Fastening Cable Body  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.3  
Recommended Dimensions for User System Mount Pad  
Figure 7 shows the recommended dimensions for the mount pad (footprint) for the user system with  
an IC socket for an TBP-112 package (CSPACK112A1110H01: socket (manufactured by Tokyo  
Eletech Corporation). Note that the dimensions in figure 7 are somewhat different from those of the  
actual chip's mount pad.  
Figure 7 Recommended Dimensions for Mount Pad  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.4  
Dimensions for User System Interface Cable Head  
The dimensions for the user system interface cable head are shown in figure 8.  
Figure 8 Dimensions for User System Interface Cable Head  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
2.5  
Resulting Dimensions after Connecting User System Interface Cable  
The resulting dimensions, after connecting the user system interface cable head to the user system,  
are shown in figure 9.  
Figure 9 Resulting Dimensions after Connecting User System Interface Cable  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 3 Installing the MCU to the User System  
CAUTION  
1. Check the location of pin 1 before inserting.  
2. Use a provided screwdriver.  
3. The tightening torque must be 0.054 N•m or less.  
If the applied torque cannot be accurately measured,  
stop tightening when the force required to turn the screw  
becomes significantly greater than that needed when first  
tightening. If a screw is tightened too much, the screw  
head may break or an IC socket contact error may be  
caused by a crack in the IC socket solder.  
4. If the MCU does not operate correctly, cracks might have  
occurred in the solder.  
1. Attach the spacer and cover to the IC socket.  
2. Place the spacer on the IC socket. Place the two guide pins of the spacer in the corresponding  
holes on the IC socket.  
3. Place the MCU gently in the opening of the spacer. Be sure to correctly align pin 1 of the  
MCU with the IC socket. The solder balls of the MCU will then be in the correct locations  
relative to the connection pins of the IC socket.  
4. Put the cover on the spacer. The four holes at the four corners of the spacer and of the cover  
must be aligned. Use the four screws to fasten the cover to the IC socket. Each screw in turn  
should be made a little tighter, alternating between screws on opposing corners. Use the  
screwdriver provided with the package. The torque in tightening must be 0.054 Nm or less.  
5. When removing the cover from the IC socket, hold the side of the cover so that no stress is  
applied to the soldered connections between the IC socket and user system while the screws  
on the cover are being unscrewed. Use tweezers to remove the MCU from the opening in the  
spacer,  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Figure 10 Installing MCU to User System  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 4 Verifying Operation  
1. When using the E6000 emulator for the H8S/2214 series, turn on the emulator according to the  
procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE).  
2. Verify the user system interface cable connections by accessing the external memory and ports  
to check the bus states of the pins with the MEMORY_FILL command (emulator command). If  
an error is detected, recheck the soldered IC socket and the location of pin 1.  
3. The emulator connected to this user system interface cable supports two kinds of clock sources  
as the MCU clock: an emulator internal clock and an external clock on the user system. For  
details, refer to the Emulator Supplementary Information (HS2214EPI61HE).  
To use the emulator internal clock  
Select the clock in the emulator station as the system clock (φ), by using the CLOCK  
command (emulator command).  
To use the external clock on the user system  
Supply the external clock from the user system to the emulator. Connect a crystal oscillator  
to the EXTAL and XTAL terminals for the system clock (φ). Select the external clock as the  
system clock (φ), by using the CLOCK command (emulator command). For details, refer to  
section 16, Clock Pulse Generator, in the H8S/2214 Series Hardware Manual.  
Figure 11 shows the oscillator circuit on the user system interface cable.  
R1 1 M  
HCU04  
HCU04  
HCU04  
To E6000 emulator  
R2 270  
EXTAL XTAL  
Figure 11 Oscillator Circuit  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Section 5 Notice  
1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  
head before inserting the cable head into the user system IC socket.  
2. The dimensions of the recommended mount pad for the user system IC socket are different from  
those of the MCU.  
3. This user system interface cable is specifically designed for the HS2214EPI61H emulator. Do  
not use this cable with any other emulator station.  
4. To prevent breaking of wires in the cable body, do not place heavy or sharp metal objects on the  
user system interface cable.  
5. While the emulator station is connected to the user system with the user system interface cable,  
force must not be applied to the cable head. Place the emulator station, user system interface  
cable, and user system as shown in the example in figure 12.  
Figure 12 User System Interface Cable Location Example  
6. The P1 short connector is used for testing. Do not remove the short pin that is inserted in the side  
of pin 1 and pin 2.  
Figure 13 Short Connector  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Radio Shack Cordless Telephone ET 536 User Guide
Radio Shack Cordless Telephone ET 689 User Guide
RedMax Drill AG4300 User Guide
Remington Electric Shaver NE 300 User Guide
Renesas Computer Hardware M3A HS25 User Guide
Samsung All in One Printer 4200 User Guide
Samsung Satellite TV System DTB H260F User Guide
Savin Printer SDC103 User Guide
Sears Snow Blower 24788852 User Guide
Senco Air Compressor PC2053 1 User Guide