Marine
Elegance
Toilet
Installation and Maintenance Instructions
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING: RaritanEngineeringCompany,Inc.recommendsthataqualifiedpersonorelectricianinstall
this product. Equipment damage, injury to personnel or death could result from improper
installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for
damagetoequipment,injuryordeathtopersonnelthatmayresultfromimproperinstallation
or operation of this product.
WARNING: HAZARD OF SHOCK OR FIRE
Alwaysuserecommendedfuse, circuitbreakerandwiresize.
Motors used with this product are “Ignition Protected”. They are not however, explosion-
proofasdefinedin46CFR110.15-65(e),SubchapterJ-ElectricalEngineering.
DONOTruncontinuouslyformorethan30seconds.
Desription:
Pressurized
Freshwater Model
Marine elegance toilet is available in 12V or 24V
DC. Bowls are available in four models: standard with
angled back, standard with straight back, tall with
angled back and tall with straight back.Fresh water
model utilizes onboard freshwater, the Sea water
model utilizes a remote pump installed between raw
water source and bowl. Sea/Fresh model can switch
between fresh and raw water source.
Three different control options are available:
1. Smart flush control: provides timed operation
and independant control of water and discharge
2. ME toilet control: provides momentary opera-
tion and independant momentary control of water
and discharge
Sea Water Model
(Remote Pump)
3. Push button switch: providing only the ability to
flush with no independant control of water or
Download from Www.Somanuals.com. All Manuals Search And Download.
A. Push Button Switch:
Presspush-buttonswitchandholduntilallwaste
is cleared from the toilet bowl.
B. ME Toilet Control:
1. Press and hold “Water Only” to add water
to the bowl
2. Pressandhold“Empty”toevacuatethebowl
3. Press and hold “Flush” to bring water in
while bowl is evacuating
C. Multifunction Smart Switch:
1. Empty Only:Press Empty Only button to
evacuate the bowl. Discharge pump runs as
long as this button is held.
2. Water Only: Press Water Only switch to
add water in the bowl. Inlet water solenoid/
pump runs as long as button is pressed with
a seven seconds limit. After limit is reached
Water Only button is disabled to prevent
overflowofthebowl.Toenableagain, Empty
Only button must be pressed.
3. Normal: Press normal button once and
timed flushing cycle starts.
4. Water saver: Press the button and a water
saver cycle starts.
NOTE: Holding tank full light will only illuminate if
the tank sensor has been added to the control.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming of Toilet Flush Control
NOTE: Flush control is set at factory to work in most
key push. Note: If the button is pushed 9 times it will
start back at zero.
installations and no additional programming is needed.
Use following instructions to re-program if adjustment
on water levels and timings are needed.
Once this is done push the “NORMAL” button to
store this value (the unit will flash three times
indicating the time has been set and you have left
program mode).
Programming timing for “NORMAL” flush cycle:
Normal cycle has initial fill time (T1), Discharge pump
time (T2), and water retention fill time (T3). All three
times (T1,T2 and T3) are programmable.
Programming the WATER ONLY Disable
Features:
1. Hold the WATER ONLY & EMPTY buttons
down together for three seconds. The holding
tank full LED will give THREE flashes indicat-
ing you have entered program mode .
Factory setting : T1=3 sec, T2=2 sec, T3= 3 sec,
To change any of the above settings re-programming is
needed
Step 1 – Placing the unit in program mode:
2. Push the WATER SAVER button. TheWATER
ONLY and EMPTY buttons now can be dis-
abled or enabled:
Hold the WATER ONLY & EMPTY buttons down
together for three seconds. The Holding Tank Full
LED will give three quick flashes indicating you have
entered program mode - release both buttons.
3. Pushing the WATER ONLY button will disable
both WATER ONLY and EMPTY buttons. The
holding tank full LED will give THREE flashes
indicating you have left program mode.
Setting T1 initial fill time:
After placing the unit in program mode (Step 1 above)
push the “Normal Flush” button the number of times
required for the Water Valve/Inlet Pump time (one
push = 1 sec’s, two = 2 sec’s., etc.) the Tank LED
will flash once indicating a valid key push.
Repeat steps 1 to 3 to re-enable these buttons.
The WATER ONLY button can be set to only
work after the EMPTY button has been
pushed: (prevents children from flooding the toilet)
Note: If the button is pushed 9 times it will start back
at 2 seconds. Once this is done, push the EMPTY
button to store this value (the unit will flash three times
indicating the time has been set and you have left
program mode).
To program this feature
1. Repeat steps 1 and 2 above
2. Pushing the EMPTY button will enable this
feature. The holding tank full LED will give
THREE flashes indicating you have left
program mode. Repeat steps 1 and 2 to disable
these features.
Setting T2 Discharge Pump Time:
After placing the unit in program mode (Step 1 above)
push the EMPTY button the number of times required
for the Discharge Pump time (one push = one second,
etc.) the Tank LED will flash once indicating a valid
key push.
Programming the Holding Tank Full Lockout
Disable Features:
1. Hold the WATER ONLY & EMPTY buttons
down together for three seconds. The holding
tank full LED will give THREE flashes indicat-
ing you have entered program mode .
Note: If the button is pushed 9 times it will start back
at 1 second. Once this is done push the NORMAL
button to store this value (the unit will flash three times
indicating the time has been set and you have left
program mode).
2. Push the WATER SAVER button. This will
place control in disable/enable mode
Setting T3 Water retention fill Time:
3. Pushing the WATER SAVER button again. The
holding tank full LED will give THREE flashes
indicating you have left program mode.
After placing the unit in program mode (Step 1 above)
push the WATER ONLY button the number of times
required for the Water Valve/Inlet Pump time (one
push = ZERO sec’s, two = 1 sec. three = 2 sec’s.,
Repeat steps 1 to 3 to re-enable Holding Tank Full
Lockout feature..
etc.) the Tank LED will flash once indicating a valid
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Integral and Remote Intake Pump Models
Parts Required
3/4" (19 mm.) I.D. intake hose approximately 3 feet
(1 m.) long.
1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose
approximately 3 feet (1 m.) long.
Two buckets
Nontoxic antifreeze approximately 1 quart (1 liter)
Steps
1. Close the intake and discharge seacocks.
2. Turn off power to unit.
Winterizing:
•
Improper winter lay up is a major cause of marine
toiletfailure.
3. Disconnect and drain intake hose and discharge
hose .
•
•
Use only nontoxic antifreeze.
Flush toilet several times to clear waste from
system.
4. Connect short hoses to toilet’s intake and discharge.
5. Place one bucket under hose connected to toilet’s
discharge.
•
•
Dispose of all antifreeze in accordance with local
and federal regulations.
Winterize holding tanks, plumbing, treatment
systems (MSD’s), etc. independently following
manufacturer’s instructions.
6. Pour nontoxic antifreeze in other bucket.
7. Place hose connected to intake pump into bucket
with antifreeze.
8. Turn on power to unit and flush toilet until
antifreeze begins to be discharged from toilet.
9. Disconnect power from toilet.
Pressurized Freshwater Models
Parts Required
RECOMMISSIONING
•
1" (25 mm.) or 1 1/2" (38 mm.) I.D.
discharge hose, approximately 3 feet (1 m.) long
Two buckets
Nontoxic antifreeze approximately 1 quart
(1 liter)
1. Using the buckets, hoses and approximately one
gallon (3.8 liters) of clean fresh water, flush
antifreeze out of the toilet (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.
•
•
2. Reconnect the intake and discharge hoses and
open both seacocks and water source valve.
3. Check all connections for leaks with several test
flushes.
Steps
1. Close discharge seacock (if one exists).
2. Shut off intake water at source.
3. Turn off power to unit.
4. Disconnect and drain discharge hose.
5. Disconnect intake hoses from water solenoid and
place in one of the buckets.
6. Connect short hose to toilet’s discharge and place
in other bucket.
7. Pour antifreeze in bowl.
8. Turn on power to unit and flush until antifreeze is
removed from the bowl and water is drained from
the solenoid and hose.
9. Disconnect power to toilet.
10. Reconnect intake hoses to water solenoid
SYSTEM START-UP
1. Open seacock(s).
NOTE: Pressurized freshwater models; open water
source valve.
2. Turn on power to toilet.
3. Flush toilet per Operation Instructions.
4. Check for leaks.
IMPORTANT: If toilet does not flush properly
or if water does not enter the bowl within 10
seconds, refer to Troubleshooting.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Plumbing
Maximum suction of Intake pump
CONVERSIONS
Wire - AWG to mm2
4 Ft. (1.2m) from Intake Pump.
(Maximum height above waterline)
AWG 16
14
12
10
8
6
4
2
Maximum height of discharge vented loop 10 Ft. (3 m) from base of toilet.
mm2
1.5
2.5
4.0
6.0
10.0 16.0 25.0 35.0
flow rate of 3.5 gpm (13.25 liters) at
Pressurized water source minimum
10psi(70 K pa)
requirements
shutoff pressure of 5 psi (34.5 kPa).
Feet to Meters
Feet
10
15
20
25
30
40
50
NOTES: for Wiring
1.
Distances are from source to unit and back to source.
Meter 3.1
4.6
6.1
7.6
9.2
12.2 15.2
Distance from power source to remote intake pump MUST be included when
determining total distance.Same wire size MUST be used for lower base and
remote intake pump.
2.
Hose Sizes
INLET
3.
4.
5.
Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.
1/2”(12.7 mm.) for freshwater model
3/4” (19 mm.) for sea water model
Discharge
1”(25.4 mm.) or 1 1/2”(38 mm.)
Recommended conductor sizes are based on 105oC rated insulation.
Refer to ABYC Standards for other insulation ratings.
For 120/240 VAC units use 24VDC specifications from transformer to unit.
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
Elegance
Remote
Pump
Only
toilet
Circuit
Breaker/fuse
size (amps)
Amp. draw
@ nominal
Voltage/
Units
Voltage
15
feet
20
feet
30
feet
40
feet
50
feet
Amp. draw
@ nominal
voltage
12 VDC
24 VDC
30
20
18
10
10
5
10 AWG 8 AWG
6 AWG
6 AWG
4 AWG
14 AWG 14 AWG 12 AWG 10 AWG 10 AWG
Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size
Circuit
Breaker/fuse
size (amps)
10
feet
15
feet
20
feet
30
feet
40
feet
50
feet
Amp. draw
@ nominal
voltage
Units
Voltage
12 AWG 10 AWG 10 AWG 8 AWG
6 AWG
6 AWG
6 AWG
12 VDC
25
15
18
10
14 AWG 12 AWG 10 AWG 10 AWG 8 AWG
24 VDC
A
E
SIZE
See Table
C
D
B
F
G
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts included with all models
1. Toilet bowl assembly
2. Mounting bracket kit
Additional Parts Required
•
•
•
1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose
3/4" (19 mm.) I.D. reinforced intake hose
3/4" (19 mm.) and 1" (25 mm.) or 1 1/2" (38 mm.)
hose clamps (two for each connection below
waterline)
3. Seat
4. One of the following flush controls:
a. Push Button Control
b. ME Toilet Control
•
•
•
Wire
Terminals
Fuse/circuit breaker
c. Multifunction Smart Control
5. User guide and Installation guide with labels
Additional Parts included with sea
water model:
1. Remote pump assy.
2. Relay for remote pump
Marine Elegance discharge Maximum recommended 1” PVC hose length
14
12
NOTE:
1. Each 90 degree Elbow is equal to 4 feet of hose
2. Each insert coupling is equal to 2 feet of hose
3. Each Y-valve is equal to 10 feet of hose
Example
: An installation has 50' of straight run with two elbow and a
10
Y- valve, what is maximum height of loop allowed?
Answer: equivalent hose length = 50' +8'(two elbows)+10'(Y-valve)
= 68'
Vertical height (Feet)
From chart horizontal distance of 68' gives a vertical dist. @ 7'
Hence a maximum of 7' high loop can be installed.
8
6
4
2
0
0
20
40
60
80
100
120
140
160
180
Horizontal distance (Feet)
Bowl type
A
B
C
D
E
F
G
ME-
angledback
18 3/8 12 1/4
(467)
14
12
14
8 1/2 2 1/8
(311) (355) (305) (355) (216) (54)
SIZE
inch (mm.)
ME-
straightback
18 3/8 12 1/4 14 12 14 8 1/2
(467) (311) (355) (305) (355) (216)
NA
ME-TALL
18 3/8 12 1/4 17 15 14 8 1/2 2 1/8
angled back
(467) (311) (432) (380) (355) (216) (54)
ME-TALL
Straight back
18 3/8 12 1/4 17 15 14 8 1/2
NA
(467)
(311) (432) (380) (355) (216)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
To install the toilet:
A. Prepare mounting location
B. Install plumbing
Fig. 1
C. Install controls and complete wiring
D. Connect hoses and wiring to toilet
E. Mount toilet
A. Preparation for Mounting Toilet
Mounting surface must be flat and solid.
Seat must open more than 90 degrees.
3/8”
1. Place the toilet and mark mounting holes’
center line, and outside of the bowl
(see FIG 1.) Draw a center line between two
holes. Mark front hole outside and center and
draw a line perpendicular to first center line.
DISCHARGE HOSE
1 5/8” (41 mm.)
1 3/8”
WIRES
3/4”(19mm)
2”
INLET HOSE
7/8”(22 mm.)
2 1/4”
2 5/8”
2. Mark three linesA, B, and C, 3/8” from outside
lines.
3. Line up outside edges of the brackets with marked
linesA, B, and C.
4. Secure the bracket assembly to deck using #14
self threading bolts and flat washers.
Note: place bolts as close to mark linesA, B,and
C as possible
5. Drill holes for discharge (1 5/8” (41 mm.), inlet
hose(7/8”(22mm.)andwires(3/4”(19mm.)using
dimensions shown in Fig. 2.
Bolt and
washer
Line B
LineA
Note: check outside diameter of the hoses and
adjust hole sizes accordingly.
Line C
6. Complete plumbing and wiring before installing
toilet
Fig. 2
8
Download from Www.Somanuals.com. All Manuals Search And Download.
B. PLUMBING
Pressurized Freshwater Model
Installed Above/below Waterline
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline must
have a vented loop installed in the discharge
line. The top of the vented loop must be a
minimum of 4" (10 cm.) above the waterline
at the boats greatest angle of heel (see vented
loop manufacturer’s instructions).
Discharge
Shut off
Waterline
Waterline
Holding Tank
Valve
Sea Water Models must also have a vented
loop installed between the intake pump and
the toilet bowl.
Pressurized
Freshwater
Source
Double clamp all below-waterline connections.
IMPORTANT
•
Fittings and 90° bends should be kept to a
minimum.
Pressurized Freshwater Model
Installed below Waterline
•
In-Line Strainer may be installed on Sea
Water Models per Installation
Instructions. This will prevent clogs.
•
Discharging untreated sewage is forbidden
in all U. S. waters within the three-mile
limit.
•
•
•
Thru-hull fittings and seacocks must be
installed where they are easily accessible.
Use only quality reinforced hoses such as
Raritan SH.
Secure all hoses properly.
Discharge Lines
Waterline
Waterline
Electroscan
Discharge
Seacock
Remote Intake Pump Model
Mounted below Waterline
Discharge
Vented
Loop
Intake Vented
Loop
1. Connect quality sanitation hose 1" (25 mm.) or
1 1/2”(38 mm.) discharge fitting on toilet.
2. Run hose to appropriate device (i.e.: treatment
system, holding tank, etc.).
Inlet lines
Electroscan
1. Connect 1/2”(13 mm.) hose to pressurized
supply or 3/4”(19 mm.) hose to remote pump
remote
pump
Discharge
Seacock
Intake
Seacock
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Intake Lines
Pressurized Freshwater Models
Discharge
port
Install a shut off valve in intake line before water solenoid
valve.
Inlet
port
1. Connect hose from shut off valve to inlet port of
water solenoid valve at the toilet.
NOTE: To avoid malfunction of water solenoid due to
debris in water, installation of Freshwater Strainer
(190601) is recommended.
Remote Sea Water Models
Intake pump fittings are interchangeable to allow more
flexibility during installation. Inlet ports are located on
either side of intake pump. Outlet port (to toilet bowl) is
at top of intake pump.
NOTE: To avoid poor pump performance installation
of strainer (163000) is recommended
1. Slide fitting clips to open position.
2. Select inlet port to be used.
Closed
3. Install appropriate fittings into inlet and outlet ports.
NOTE: The 90° fitting can be rotated 360°.
4. Install the plug fitting into unused inlet port.
Open
Outlet Port
To Bowl
Arrow
IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage to pump will occur!
5. Slide fitting clips back to closed position.
g
6. Connect hose from seacock to inlet port of optional
In-Line Strainer if installed. Use hose clamp
provided.
From
Seacock
Inlet Ports
7. Connect hose from outlet port of In-Line Strainer to
inlet port of intake pump. Use hose clamp provided.
IMPORTANT: Double clamp all below waterline
hose connections!
From
Strainer
8. Connect hose from outlet port of intake pump to
bowl elbow located on back of toilet bowl.
To Intake
Pump
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting Remote Pump:
1. Locate remote pump between thru hull fitting and
toilet bowl.
2. Locate in an area away from berth to keep noise
level down.
3. Use Inline Strainer (optional) to avoid clogs.
4. Secure remote pump to the floor using four bolts
through the pump base.
C. Mounting controls:
A. Push Button Switch: (see fig 11)
•
•
•
Mount Push Button Switch in an accessible
location.
Make certain wires can be routed to Push
Button Switch.
Wire terminals must have clearance when
installed.
1/4” min clearance from terminals
1. Drill 5/8" (16mm) hole.
2. Attach wires to Push Button Switch terminals (see
wiring section).
3. Install Push Button Switch through back of
mounting surface.
4. Install waterproof nut on Push Button Switch.
5. Secure in place with inner nut.
Fig.11
B. ME Toilet Control:
1. Cut out a hole per Fig. 12, mark
mounting holes using wall plate as guide.
2. Route wire to the toilet and control.
3. Secure control with gasket using two
screws.
C. Smart Flush Control:
CUT OUT
1. Cut out a hole per Fig. 13, mark mounting
holes using wall plate as guide.
2. Route wire to the toilet and control.
3. Secure control using mounting
screws
Install the Warning Label (L322) where it can be
easily seen.
Fig. 12
Multifunctional Manual Switch
11
Download from Www.Somanuals.com. All Manuals Search And Download.
D. WIRING
WARNING: Hazard of Shock and Fire
•
Always use proper wire, wire connectors and
fuse/circuit breaker. See Specification
Chart.
•
•
•
•
Secure wire properly.
Do not connect appliances to toilet circuit.
Make sure power is off before proceeding.
Use proper wire terminals for all wire
connections.
CUT
OUT
1. Determine proper wire size by measuring distance
from:
•
Power Source to push button to toilet motor
and back to power source.
•
Remote pump units - also include distance
from power source for remote pump to
remote pump and back. Same wire gauge
must be used for both lower base and remote
pump.
Smart Flush Control
Fig. 13
2. Select proper wire and fuse/circuit breaker size
from Specifications on Installation page.
3. Installfuse/circuitbreakerinpositivelineatsource.
4. Wire control to the toilet and battery using one of
the following wiring diagrams.
ELECTROSCAN OPERATION
To start Electroscan from toilet control, run a wire
from “to EST “ to terminal marked “EXT TRIG”
inside Electroscan control module (black box).
To start Elegance equipped with Smart Switch from
Electroscan, connect “Head1” to “FROM EST “.
For Lectra/San MC, call Raritan Customer Service
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Solenoid valve
To EST
Push Button
RED
Fuse
Black
Black
RED
Discharge pump
BATTERY
Fig. 14 Wiring for Push Button Switch
Fresh water model
Push Button
To EST
RED
Pump
Blue
Relay
Fuse
RED
RED
Black
Discharge pump
BATTERY
Fig. 14A Wiring for Push Button
Switch Remote pump model
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 15 WIRINGFOR SMART SWITCH FRESHWATER MODEL
FLUSH
CONTROL
PANEL
Solenoid Valve
orange
FUSE/BREAKER
black
black
black
red
red
to EST EXT TRIG
Discharge Pump
from EST
holdingtankfull
panel
BATT
Fig. 16 WIRING FOR SMART SWITCH REMOTE PUMPMODEL
orange
PUMP
remote
FLUSH
CONTROL
PANEL
Relay
red
black
FUSE/BREAKER
black
red
to EST EXT TRIG
Discharge Pump
EST input
tank full switch
panel
BATT
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Fig. 17 WIRINGFOR ME TOILET CONTROL FRESHWATER MODEL
FLUSH
CONTROL
PANEL
Solenoid Valve
orange
fuse/Breaker
black
red
red
black
black
To EST
Discharge Pump
Panel
BATT
Control Box
Fig. 18 WIRING FOR ME TOILET CONTROL WITH REMOTE PUMP
pump
black
orange
Relay
FLUSH
CONTROL
PANEL
red
red
red
black
fuse/Breaker
black
RED
To EST
Discharge Pump
Panel
BATT
Control Box
15
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Connect Hoses and wiring to toilet
Fig. 19
5. Route wire from control per wiring diagrams.
6. Install seat. I nstall discharge support strap between
seat nut and the bowl per Fig. 19A.
7. Install toilet in place, connect hoses and wireplugs.
(see Fig. 19)
Caution: Do not pull on the discharge hose to avoid
kinking
Fig. 19A
Discharge support strap
Fig. 20
E. Mount toilet
8. Install mounting bushings, bolts. (See Fig. 20)
9. Tighten bolts being careful to not overtighten (Do
not exceed 30 inch lb. when tightening)
10. Install caps over mounting bolts.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the toilet, be sure that all power
totheunithasbeenturnedoff.
WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before work-
ingontoilet.
NOTE:
The following information reflects the most probable causes and solutions to problems although not
every possible cause and solution is provided.
Any questions regarding servicing or operation of the Marine Elegance should be directed to our Technical Support
Department in Millville, NJ or Ft. Lauderdale, FL. Please have model and serial number available before calling.
PROBLEM
POSSIBLE CAUSE
SOLUTION
1. Poor pumpout, especially
solids.
1A. Cloggeddischargeline.
1A. Besuredischargeseacockisopen. Clearline, remove
clog.
1B. Plumbing restrictions, bends and ells.
1C. Clogged vents.
1D. Mineral buildup in hoses and fittings.
1E. Low voltage.
1B. Replumb to eliminate bends and ells.
1C. Clean holding tank vent and vented loop vents
1D. Cleanorreplaceaffectedparts.Replacehoseifneeded.
1E. Check voltage at toilet while toilet is running. If
less than nominal voltage of toilet (12 or 24), check
condition of batteries and wire sizes. Check terminals
and wire connections for corrosion (heat at terminals
andjunctionsindicatesabadorcorrodedconnection).
2. Poorwaterflow, especially
at front of bowl (or no wa-
ter flow).
2A. Toilet not level.
2B. Restriction in intake line.
2C. Pump sucking air.
2A. Raise rear of toilet; check with level.
2B. Be sure seacock is open. Clear line-remove clog.
2C. Check all connections from intake thru-hull to intake
pump to be sure no air leaks are present.
2D. See1E,above.
2D. Low voltage.
2E. Clogged strainer.
3A. “Marine life” lodged in rim of bowl.
2E. Remove or Clear debris from strainer.
3A. Removeandflushbowlwithpressurehosetoremove
all material. Install strainer in intake line to avoid re-
currence.
3. Foulodorsfromtoiletarea.
4. Bowl fills while underway.
3B. Permeateddischargehose.
3C. Sewage remaining in discharge line.
3B. Replace hose with Raritan sanitation hose (#SH).
3C. Flush toilet longer; replace hose if permeated; reroute
hose making a shorter run if possible.
4A. Close intake, then discharge seacock to determine
which is causing problem. If discharge, be sure the
vent or vented loop is clean. If intake, there is too
muchpressureonseacock;contactRaritanTechnical
Support.
4A. Pressurebuildupatseacocks.
5. Water leaking from under
unit.
5A. Leaking Bowl Throat adapter.
5B. Leak at shaft seal.
5A. Tightenadapterclamps.
5B. Check seal and motor shaft.
5C. Leak from bowl spud.
5C. Checkandreseatbowlgrommet
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Marine Elegance PARTS LIST
162135 Cone Seal
162225 O-Ring
162305 Lower Housing includes #162315
221100 Toilet Bowl,standard, angled, White(1)
221100A Toilet bowl Bone(1)
2210012 Discharge Pump Assembly (1)
221012 MOTOR: 12 VDC (1)
221024 MOTOR: 24V DC (1)
162310 Diaphragm includes #162315
162315 Piston (4)
162320 Piston Seat (4) includes #162315
162325A Bearing Plate Assembly includes #162315
162405 3/4" Hose Barb - 90° Fitting
162410 3/4" Hose Barb - Straight Fitting (2)
221105 O-RING (1)
221110 Discharge Pump Seal Plate (1)
221115 Discharge Pump Macerator Housing(1)
221120 Bowl Throat Adapter (1)
221125 Bowl Throat Adapter Clamp (small)(1)
221130 Bowl Throat Adapter Clamp - Large (1)
221135 JOKER VALVE (Custom) (2)
221140 Discharge Hose (Custom)(1)
221145 Discharge Adapter Fitting(1)
221150 Uni Seal 1/2” (1)
221155 Discharge Pump Mounting Bracket(1)
221156 Discharge Mtg Bracket Straight Back Model
221160 Discharge Hose Clamp - Small (1)
221165 Discharge Hose Clamp - Large (1)
221170 Discharge hose strap(not shown)
221175 L bolts2(2) ( not shown)
162415
162420
162425
F005
Plug Fitting
Fitting Clip (3)
Fitting O-Ring (4)
Set Screw
F172
F144
Piston Fastener (4)
Mounting Bolt Washer (4)
F162VT Mounting Bolt
F199
1108A
Optional:
Bushing
Nut
190601 Fresh water strainer
221210 Bowl Mounting Bushing (2)
221215 Bowl Mounting Bushing Cap (2)
221300 Vacuum Breaker Assembly 1
221325 Vacuum Breaker Seal Washer (1)
221330 Vacuum Breaker O-Ring (#16)(1)
221351 Water Solenoid Valve (12V)(1)
221352 Water solenoid valve (24V)(1)
221355 Water Line Adapter (1)
163000 Raw water strainer
NOT SHOWN;
221101 Toilet Bowl ,Standard,Straight White
231101 Toilet Bowl Tall Straight White
231100 Toilet Bowl TallAngled White
Note: add suffics “A “for bone
1245
1245A Seat and cover , Bone
214** Relay
Seat and cover, white
221335 1/2" Hose 2.25" L (1)
221340 1/2" Clamps (2)
31-102 Motor Shaft Seal
31-114 Lock Nut 10-32 W/Nylon (3)
CH20B #10 Lock washer (not shown)
Control parts (not shown):
SSFC02 Smart Control Box
SSFC 03 Smart wall panel
SSFC04 Cable
F321
Fender washer (not shown)
F186VT Bowl Mounting Screw: (2)
F187VT Bowl Mounting Screw (1)
31-603 Cable
For Momentary Multifunction control after 02/10
221549 Momentary Multifunction control box
221524 Momentary Multifinction Bazel White
221543 Momentary Multifinction wall panel
221545 Cable for Momentary Multifunctin control
F188
Well Nut (2)
F189 Deck Mounting (3)
F193VT
F195
F196 Front mounting snap cap (1)
M23A Lockwasher
166000 Remote pump complete 12v
166100 Remote pump complete 24V
1660** Motor, raw water pump
161115 Impeller
Pump Mounting (1)
Front mounting washer (1)
Repair kits:
DIAPUMPRK inlet pump repair kit
162400 Fittings and O-rings for inlet pump
166000 Diaphragm pump complete 12V
166100 Diaphragm pump complete 24v
MERK Discharge pump repair kit
161123 Macerator Blade
* Specify DC Voltage (12, 24, 32)
18
Download from Www.Somanuals.com. All Manuals Search And Download.
221300
221150
221340(2)
221335
221351(12V)
221352(24V)
221100
221140
221165
221146
221155
F193
221135(2)
221145
221160
M23A
1108A
221105
221110
F195
F187VT
F196
221215
F199
221115
221210
31-102 2210**
161115
221130 221125
221120
F186VT
161123
Recommended
Seawater strainer
freshwaterstrainer
FIG 21
rine Elegance Exploded Parts View
19
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY
RaritanEngineeringCompanywarrantstotheoriginalpurchaserthatthisproductisfreeofdefects
inmaterialsorworkmanshipforaperiodofoneyearfromtheproduct’sdateofpurchase. Should
this product prove defective by reason of improper workmanship and/or materials within the
warrantyperiod,Raritanshall,atitssoleoption,repairorreplacetheproduct.
1. TOOBTAINWARRANTYSERVICE,Consumermustdelivertheproductprepaid,togetherwith
adetaileddescriptionoftheproblem,toRaritanat530OrangeSt.,Millville,N.J.08332,or3101SW
2ndAve.Ft.Lauderdale,FL33315. Whenrequestingwarrantyservice,purchasermustpresenta
salessliporotherdocumentwhichestablishesproofofpurchase.THERETURNOFTHEOWNER
REGISTRATIONCARDISNOTACONDITIONPRECEDENTOFWARRANTYCOVERAGE.
However,pleasecompleteandreturntheownerRegistrationCardsothatRaritancancontactyou
shouldaquestionofsafetyarisewhichcouldaffectyou.
2. THISWARRANTYDOESNOTCOVERdefectscausedbymodifications,alterations,repairsor
serviceofthisproductbyanyoneotherthanRaritan;defectsinmaterialsorworkmanshipsupplied
byothersintheprocessofinstallationofthisproduct;defectscausedbyinstallationofthisproduct
otherthaninaccordancewiththemanufacturer’srecommendedinstallationinstructionsorstandard
industryprocedures;physicalabuseto,ormisuseof,thisproduct. Thiswarrantyalsodoesnotcover
damagestoequipmentcausedbyfire,flood,externalwater,excessivecorrosionorActofGod.
3. ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN,ANDANYREMEDYFORBREACH
OFCONTRACTWHICHBUTFORTHISPROVISIONMIGHTARISEBYIMPLICATIONOR
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A
TERMOFONEYEAR. SOMESTATESDONOTALLOWLIMITATIONSONHOWLONGA
LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER
ARISINGOUTOFBREACHOFWARRANTY, BREACHOFCONTRACT,OROTHERWISE.
SOMESTATESDONOTALLOWTHEEXCLUSIONORLIMITATIONOFINCIDENTALOR
CONSEQUENTIALDAMAGES,SOTHEABOVELIMITATIONOREXCLUSIONMAYNOT
APPLY TO YOU.
5. Nootherpersonorentityisauthorizedtomakeanyexpresswarranty,promiseoraffirmationoffact
or to assume any other liability on behalf of Raritan in connection with its products except as
specificallysetforthinthiswarranty.
6. Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfrom
statetostate.
530 Orange Street, Millville, NJ 08332 USA
Telephone: 856-825-4900 FAX: 856-825-4409
Southern Office and Plant:
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone: 954-525-0378 FAX: 954-764-4370
L460 0610vkm
Specifications Subject to Change Without Notice
Printed in U.S.A.
20