Raritan Engineering Plumbing Product toilet User Guide

Marine  
Elegance  
Toilet  
Installation and Maintenance Instructions  
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND  
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.  
WARNING: RaritanEngineeringCompany,Inc.recommendsthataqualifiedpersonorelectricianinstall  
this product. Equipment damage, injury to personnel or death could result from improper  
installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for  
damagetoequipment,injuryordeathtopersonnelthatmayresultfromimproperinstallation  
or operation of this product.  
WARNING: HAZARD OF SHOCK OR FIRE  
Alwaysuserecommendedfuse, circuitbreakerandwiresize.  
Motors used with this product are “Ignition Protected”. They are not however, explosion-  
proofasdefinedin46CFR110.15-65(e),SubchapterJ-ElectricalEngineering.  
DONOTruncontinuouslyformorethan30seconds.  
Desription:  
Pressurized  
Freshwater Model  
Marine elegance toilet is available in 12V or 24V  
DC. Bowls are available in four models: standard with  
angled back, standard with straight back, tall with  
angled back and tall with straight back.Fresh water  
model utilizes onboard freshwater, the Sea water  
model utilizes a remote pump installed between raw  
water source and bowl. Sea/Fresh model can switch  
between fresh and raw water source.  
Three different control options are available:  
1. Smart flush control: provides timed operation  
and independant control of water and discharge  
2. ME toilet control: provides momentary opera-  
tion and independant momentary control of water  
and discharge  
Sea Water Model  
(Remote Pump)  
3. Push button switch: providing only the ability to  
flush with no independant control of water or  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A. Push Button Switch:  
Presspush-buttonswitchandholduntilallwaste  
is cleared from the toilet bowl.  
B. ME Toilet Control:  
1. Press and hold “Water Only” to add water  
to the bowl  
2. PressandholdEmptytoevacuatethebowl  
3. Press and hold “Flush” to bring water in  
while bowl is evacuating  
C. Multifunction Smart Switch:  
1. Empty Only:Press Empty Only button to  
evacuate the bowl. Discharge pump runs as  
long as this button is held.  
2. Water Only: Press Water Only switch to  
add water in the bowl. Inlet water solenoid/  
pump runs as long as button is pressed with  
a seven seconds limit. After limit is reached  
Water Only button is disabled to prevent  
overflowofthebowl.Toenableagain, Empty  
Only button must be pressed.  
3. Normal: Press normal button once and  
timed flushing cycle starts.  
4. Water saver: Press the button and a water  
saver cycle starts.  
NOTE: Holding tank full light will only illuminate if  
the tank sensor has been added to the control.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming of Toilet Flush Control  
NOTE: Flush control is set at factory to work in most  
key push. Note: If the button is pushed 9 times it will  
start back at zero.  
installations and no additional programming is needed.  
Use following instructions to re-program if adjustment  
on water levels and timings are needed.  
Once this is done push the “NORMAL” button to  
store this value (the unit will flash three times  
indicating the time has been set and you have left  
program mode).  
Programming timing for “NORMAL” flush cycle:  
Normal cycle has initial fill time (T1), Discharge pump  
time (T2), and water retention fill time (T3). All three  
times (T1,T2 and T3) are programmable.  
Programming the WATER ONLY Disable  
Features:  
1. Hold the WATER ONLY & EMPTY buttons  
down together for three seconds. The holding  
tank full LED will give THREE flashes indicat-  
ing you have entered program mode .  
Factory setting : T1=3 sec, T2=2 sec, T3= 3 sec,  
To change any of the above settings re-programming is  
needed  
Step 1 – Placing the unit in program mode:  
2. Push the WATER SAVER button. TheWATER  
ONLY and EMPTY buttons now can be dis-  
abled or enabled:  
Hold the WATER ONLY & EMPTY buttons down  
together for three seconds. The Holding Tank Full  
LED will give three quick flashes indicating you have  
entered program mode - release both buttons.  
3. Pushing the WATER ONLY button will disable  
both WATER ONLY and EMPTY buttons. The  
holding tank full LED will give THREE flashes  
indicating you have left program mode.  
Setting T1 initial fill time:  
After placing the unit in program mode (Step 1 above)  
push the “Normal Flush” button the number of times  
required for the Water Valve/Inlet Pump time (one  
push = 1 sec’s, two = 2 sec’s., etc.) the Tank LED  
will flash once indicating a valid key push.  
Repeat steps 1 to 3 to re-enable these buttons.  
The WATER ONLY button can be set to only  
work after the EMPTY button has been  
pushed: (prevents children from flooding the toilet)  
Note: If the button is pushed 9 times it will start back  
at 2 seconds. Once this is done, push the EMPTY  
button to store this value (the unit will flash three times  
indicating the time has been set and you have left  
program mode).  
To program this feature  
1. Repeat steps 1 and 2 above  
2. Pushing the EMPTY button will enable this  
feature. The holding tank full LED will give  
THREE flashes indicating you have left  
program mode. Repeat steps 1 and 2 to disable  
these features.  
Setting T2 Discharge Pump Time:  
After placing the unit in program mode (Step 1 above)  
push the EMPTY button the number of times required  
for the Discharge Pump time (one push = one second,  
etc.) the Tank LED will flash once indicating a valid  
key push.  
Programming the Holding Tank Full Lockout  
Disable Features:  
1. Hold the WATER ONLY & EMPTY buttons  
down together for three seconds. The holding  
tank full LED will give THREE flashes indicat-  
ing you have entered program mode .  
Note: If the button is pushed 9 times it will start back  
at 1 second. Once this is done push the NORMAL  
button to store this value (the unit will flash three times  
indicating the time has been set and you have left  
program mode).  
2. Push the WATER SAVER button. This will  
place control in disable/enable mode  
Setting T3 Water retention fill Time:  
3. Pushing the WATER SAVER button again. The  
holding tank full LED will give THREE flashes  
indicating you have left program mode.  
After placing the unit in program mode (Step 1 above)  
push the WATER ONLY button the number of times  
required for the Water Valve/Inlet Pump time (one  
push = ZERO sec’s, two = 1 sec. three = 2 sec’s.,  
Repeat steps 1 to 3 to re-enable Holding Tank Full  
Lockout feature..  
etc.) the Tank LED will flash once indicating a valid  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Integral and Remote Intake Pump Models  
Parts Required  
3/4" (19 mm.) I.D. intake hose approximately 3 feet  
(1 m.) long.  
1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose  
approximately 3 feet (1 m.) long.  
Two buckets  
Nontoxic antifreeze approximately 1 quart (1 liter)  
Steps  
1. Close the intake and discharge seacocks.  
2. Turn off power to unit.  
Winterizing:  
Improper winter lay up is a major cause of marine  
toiletfailure.  
3. Disconnect and drain intake hose and discharge  
hose .  
Use only nontoxic antifreeze.  
Flush toilet several times to clear waste from  
system.  
4. Connect short hoses to toilet’s intake and discharge.  
5. Place one bucket under hose connected to toilet’s  
discharge.  
Dispose of all antifreeze in accordance with local  
and federal regulations.  
Winterize holding tanks, plumbing, treatment  
systems (MSD’s), etc. independently following  
manufacturer’s instructions.  
6. Pour nontoxic antifreeze in other bucket.  
7. Place hose connected to intake pump into bucket  
with antifreeze.  
8. Turn on power to unit and flush toilet until  
antifreeze begins to be discharged from toilet.  
9. Disconnect power from toilet.  
Pressurized Freshwater Models  
Parts Required  
RECOMMISSIONING  
1" (25 mm.) or 1 1/2" (38 mm.) I.D.  
discharge hose, approximately 3 feet (1 m.) long  
Two buckets  
Nontoxic antifreeze approximately 1 quart  
(1 liter)  
1. Using the buckets, hoses and approximately one  
gallon (3.8 liters) of clean fresh water, flush  
antifreeze out of the toilet (see Winterizing).  
Dispose of antifreeze in accordance with local  
and federal regulations.  
2. Reconnect the intake and discharge hoses and  
open both seacocks and water source valve.  
3. Check all connections for leaks with several test  
flushes.  
Steps  
1. Close discharge seacock (if one exists).  
2. Shut off intake water at source.  
3. Turn off power to unit.  
4. Disconnect and drain discharge hose.  
5. Disconnect intake hoses from water solenoid and  
place in one of the buckets.  
6. Connect short hose to toilet’s discharge and place  
in other bucket.  
7. Pour antifreeze in bowl.  
8. Turn on power to unit and flush until antifreeze is  
removed from the bowl and water is drained from  
the solenoid and hose.  
9. Disconnect power to toilet.  
10. Reconnect intake hoses to water solenoid  
SYSTEM START-UP  
1. Open seacock(s).  
NOTE: Pressurized freshwater models; open water  
source valve.  
2. Turn on power to toilet.  
3. Flush toilet per Operation Instructions.  
4. Check for leaks.  
IMPORTANT: If toilet does not flush properly  
or if water does not enter the bowl within 10  
seconds, refer to Troubleshooting.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Plumbing  
Maximum suction of Intake pump  
CONVERSIONS  
Wire - AWG to mm2  
4 Ft. (1.2m) from Intake Pump.  
(Maximum height above waterline)  
AWG 16  
14  
12  
10  
8
6
4
2
Maximum height of discharge vented loop 10 Ft. (3 m) from base of toilet.  
mm2  
1.5  
2.5  
4.0  
6.0  
10.0 16.0 25.0 35.0  
flow rate of 3.5 gpm (13.25 liters) at  
Pressurized water source minimum  
10psi(70 K pa)  
requirements  
shutoff pressure of 5 psi (34.5 kPa).  
Feet to Meters  
Feet  
10  
15  
20  
25  
30  
40  
50  
NOTES: for Wiring  
1.  
Distances are from source to unit and back to source.  
Meter 3.1  
4.6  
6.1  
7.6  
9.2  
12.2 15.2  
Distance from power source to remote intake pump MUST be included when  
determining total distance.Same wire size MUST be used for lower base and  
remote intake pump.  
2.  
Hose Sizes  
INLET  
3.  
4.  
5.  
Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.  
1/2”(12.7 mm.) for freshwater model  
3/4” (19 mm.) for sea water model  
Discharge  
1”(25.4 mm.) or 1 1/2”(38 mm.)  
Recommended conductor sizes are based on 105oC rated insulation.  
Refer to ABYC Standards for other insulation ratings.  
For 120/240 VAC units use 24VDC specifications from transformer to unit.  
Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size  
Elegance  
Remote  
Pump  
Only  
toilet  
Circuit  
Breaker/fuse  
size (amps)  
Amp. draw  
@ nominal  
Voltage/  
Units  
Voltage  
15  
feet  
20  
feet  
30  
feet  
40  
feet  
50  
feet  
Amp. draw  
@ nominal  
voltage  
12 VDC  
24 VDC  
30  
20  
18  
10  
10  
5
10 AWG 8 AWG  
6 AWG  
6 AWG  
4 AWG  
14 AWG 14 AWG 12 AWG 10 AWG 10 AWG  
Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size  
Circuit  
Breaker/fuse  
size (amps)  
10  
feet  
15  
feet  
20  
feet  
30  
feet  
40  
feet  
50  
feet  
Amp. draw  
@ nominal  
voltage  
Units  
Voltage  
12 AWG 10 AWG 10 AWG 8 AWG  
6 AWG  
6 AWG  
6 AWG  
12 VDC  
25  
15  
18  
10  
14 AWG 12 AWG 10 AWG 10 AWG 8 AWG  
24 VDC  
A
E
SIZE  
See Table  
C
D
B
F
G
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts included with all models  
1. Toilet bowl assembly  
2. Mounting bracket kit  
Additional Parts Required  
1" (25 mm.) or 1 1/2" (38 mm.) I.D. discharge hose  
3/4" (19 mm.) I.D. reinforced intake hose  
3/4" (19 mm.) and 1" (25 mm.) or 1 1/2" (38 mm.)  
hose clamps (two for each connection below  
waterline)  
3. Seat  
4. One of the following flush controls:  
a. Push Button Control  
b. ME Toilet Control  
Wire  
Terminals  
Fuse/circuit breaker  
c. Multifunction Smart Control  
5. User guide and Installation guide with labels  
Additional Parts included with sea  
water model:  
1. Remote pump assy.  
2. Relay for remote pump  
Marine Elegance discharge Maximum recommended 1” PVC hose length  
14  
12  
NOTE:  
1. Each 90 degree Elbow is equal to 4 feet of hose  
2. Each insert coupling is equal to 2 feet of hose  
3. Each Y-valve is equal to 10 feet of hose  
Example  
: An installation has 50' of straight run with two elbow and a  
10  
Y- valve, what is maximum height of loop allowed?  
Answer: equivalent hose length = 50' +8'(two elbows)+10'(Y-valve)  
= 68'  
Vertical height (Feet)  
From chart horizontal distance of 68' gives a vertical dist. @ 7'  
Hence a maximum of 7' high loop can be installed.  
8
6
4
2
0
0
20  
40  
60  
80  
100  
120  
140  
160  
180  
Horizontal distance (Feet)  
Bowl type  
A
B
C
D
E
F
G
ME-  
angledback  
18 3/8 12 1/4  
(467)  
14  
12  
14  
8 1/2 2 1/8  
(311) (355) (305) (355) (216) (54)  
SIZE  
inch (mm.)  
ME-  
straightback  
18 3/8 12 1/4 14 12 14 8 1/2  
(467) (311) (355) (305) (355) (216)  
NA  
ME-TALL  
18 3/8 12 1/4 17 15 14 8 1/2 2 1/8  
angled back  
(467) (311) (432) (380) (355) (216) (54)  
ME-TALL  
Straight back  
18 3/8 12 1/4 17 15 14 8 1/2  
NA  
(467)  
(311) (432) (380) (355) (216)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
To install the toilet:  
A. Prepare mounting location  
B. Install plumbing  
Fig. 1  
C. Install controls and complete wiring  
D. Connect hoses and wiring to toilet  
E. Mount toilet  
A. Preparation for Mounting Toilet  
Mounting surface must be flat and solid.  
Seat must open more than 90 degrees.  
3/8”  
1. Place the toilet and mark mounting holes’  
center line, and outside of the bowl  
(see FIG 1.) Draw a center line between two  
holes. Mark front hole outside and center and  
draw a line perpendicular to first center line.  
DISCHARGE HOSE  
1 5/8” (41 mm.)  
1 3/8”  
WIRES  
3/4”(19mm)  
2”  
INLET HOSE  
7/8”(22 mm.)  
2 1/4”  
2 5/8”  
2. Mark three linesA, B, and C, 3/8” from outside  
lines.  
3. Line up outside edges of the brackets with marked  
linesA, B, and C.  
4. Secure the bracket assembly to deck using #14  
self threading bolts and flat washers.  
Note: place bolts as close to mark linesA, B,and  
C as possible  
5. Drill holes for discharge (1 5/8” (41 mm.), inlet  
hose(7/8(22mm.)andwires(3/4”(19mm.)using  
dimensions shown in Fig. 2.  
Bolt and  
washer  
Line B  
LineA  
Note: check outside diameter of the hoses and  
adjust hole sizes accordingly.  
Line C  
6. Complete plumbing and wiring before installing  
toilet  
Fig. 2  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. PLUMBING  
Pressurized Freshwater Model  
Installed Above/below Waterline  
WARNING: Hazard of Flooding  
Toilets mounted at or below the waterline must  
have a vented loop installed in the discharge  
line. The top of the vented loop must be a  
minimum of 4" (10 cm.) above the waterline  
at the boats greatest angle of heel (see vented  
loop manufacturer’s instructions).  
Discharge  
Shut off  
Waterline  
Waterline  
Holding Tank  
Valve  
Sea Water Models must also have a vented  
loop installed between the intake pump and  
the toilet bowl.  
Pressurized  
Freshwater  
Source  
Double clamp all below-waterline connections.  
IMPORTANT  
Fittings and 90° bends should be kept to a  
minimum.  
Pressurized Freshwater Model  
Installed below Waterline  
In-Line Strainer may be installed on Sea  
Water Models per Installation  
Instructions. This will prevent clogs.  
Discharging untreated sewage is forbidden  
in all U. S. waters within the three-mile  
limit.  
Thru-hull fittings and seacocks must be  
installed where they are easily accessible.  
Use only quality reinforced hoses such as  
Raritan SH.  
Secure all hoses properly.  
Discharge Lines  
Waterline  
Waterline  
Electroscan  
Discharge  
Seacock  
Remote Intake Pump Model  
Mounted below Waterline  
Discharge  
Vented  
Loop  
Intake Vented  
Loop  
1. Connect quality sanitation hose 1" (25 mm.) or  
1 1/2”(38 mm.) discharge fitting on toilet.  
2. Run hose to appropriate device (i.e.: treatment  
system, holding tank, etc.).  
Inlet lines  
Electroscan  
1. Connect 1/2”(13 mm.) hose to pressurized  
supply or 3/4”(19 mm.) hose to remote pump  
remote  
pump  
Discharge  
Seacock  
Intake  
Seacock  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Intake Lines  
Pressurized Freshwater Models  
Discharge  
port  
Install a shut off valve in intake line before water solenoid  
valve.  
Inlet  
port  
1. Connect hose from shut off valve to inlet port of  
water solenoid valve at the toilet.  
NOTE: To avoid malfunction of water solenoid due to  
debris in water, installation of Freshwater Strainer  
(190601) is recommended.  
Remote Sea Water Models  
Intake pump fittings are interchangeable to allow more  
flexibility during installation. Inlet ports are located on  
either side of intake pump. Outlet port (to toilet bowl) is  
at top of intake pump.  
NOTE: To avoid poor pump performance installation  
of strainer (163000) is recommended  
1. Slide fitting clips to open position.  
2. Select inlet port to be used.  
Closed  
3. Install appropriate fittings into inlet and outlet ports.  
NOTE: The 90° fitting can be rotated 360°.  
4. Install the plug fitting into unused inlet port.  
Open  
Outlet Port  
To Bowl  
Arrow  
IMPORTANT: Be sure not to install plug fitting  
into outlet port! Damage to pump will occur!  
5. Slide fitting clips back to closed position.  
g  
6. Connect hose from seacock to inlet port of optional  
In-Line Strainer if installed. Use hose clamp  
provided.  
From  
Seacock  
Inlet Ports  
7. Connect hose from outlet port of In-Line Strainer to  
inlet port of intake pump. Use hose clamp provided.  
IMPORTANT: Double clamp all below waterline  
hose connections!  
From  
Strainer  
8. Connect hose from outlet port of intake pump to  
bowl elbow located on back of toilet bowl.  
To Intake  
Pump  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting Remote Pump:  
1. Locate remote pump between thru hull fitting and  
toilet bowl.  
2. Locate in an area away from berth to keep noise  
level down.  
3. Use Inline Strainer (optional) to avoid clogs.  
4. Secure remote pump to the floor using four bolts  
through the pump base.  
C. Mounting controls:  
A. Push Button Switch: (see fig 11)  
Mount Push Button Switch in an accessible  
location.  
Make certain wires can be routed to Push  
Button Switch.  
Wire terminals must have clearance when  
installed.  
1/4” min clearance from terminals  
1. Drill 5/8" (16mm) hole.  
2. Attach wires to Push Button Switch terminals (see  
wiring section).  
3. Install Push Button Switch through back of  
mounting surface.  
4. Install waterproof nut on Push Button Switch.  
5. Secure in place with inner nut.  
Fig.11  
B. ME Toilet Control:  
1. Cut out a hole per Fig. 12, mark  
mounting holes using wall plate as guide.  
2. Route wire to the toilet and control.  
3. Secure control with gasket using two  
screws.  
C. Smart Flush Control:  
CUT OUT  
1. Cut out a hole per Fig. 13, mark mounting  
holes using wall plate as guide.  
2. Route wire to the toilet and control.  
3. Secure control using mounting  
screws  
Install the Warning Label (L322) where it can be  
easily seen.  
Fig. 12  
Multifunctional Manual Switch  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D. WIRING  
WARNING: Hazard of Shock and Fire  
Always use proper wire, wire connectors and  
fuse/circuit breaker. See Specification  
Chart.  
Secure wire properly.  
Do not connect appliances to toilet circuit.  
Make sure power is off before proceeding.  
Use proper wire terminals for all wire  
connections.  
CUT  
OUT  
1. Determine proper wire size by measuring distance  
from:  
Power Source to push button to toilet motor  
and back to power source.  
Remote pump units - also include distance  
from power source for remote pump to  
remote pump and back. Same wire gauge  
must be used for both lower base and remote  
pump.  
Smart Flush Control  
Fig. 13  
2. Select proper wire and fuse/circuit breaker size  
from Specifications on Installation page.  
3. Installfuse/circuitbreakerinpositivelineatsource.  
4. Wire control to the toilet and battery using one of  
the following wiring diagrams.  
ELECTROSCAN OPERATION  
To start Electroscan from toilet control, run a wire  
from “to EST “ to terminal marked “EXT TRIG”  
inside Electroscan control module (black box).  
To start Elegance equipped with Smart Switch from  
Electroscan, connect “Head1” to “FROM EST “.  
For Lectra/San MC, call Raritan Customer Service  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Solenoid valve  
To EST  
Push Button  
RED  
Fuse  
Black  
Black  
RED  
Discharge pump  
BATTERY  
Fig. 14 Wiring for Push Button Switch  
Fresh water model  
Push Button  
To EST  
RED  
Pump  
Blue  
Relay  
Fuse  
RED  
RED  
Black  
Discharge pump  
BATTERY  
Fig. 14A Wiring for Push Button  
Switch Remote pump model  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 15 WIRINGFOR SMART SWITCH FRESHWATER MODEL  
FLUSH  
CONTROL  
PANEL  
Solenoid Valve  
orange  
FUSE/BREAKER  
black  
black  
black  
red  
red  
to EST EXT TRIG  
Discharge Pump  
from EST  
holdingtankfull  
panel  
BATT  
Fig. 16 WIRING FOR SMART SWITCH REMOTE PUMPMODEL  
orange  
PUMP  
remote  
FLUSH  
CONTROL  
PANEL  
Relay  
red  
black  
FUSE/BREAKER  
black  
red  
to EST EXT TRIG  
Discharge Pump  
EST input  
tank full switch  
panel  
BATT  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 17 WIRINGFOR ME TOILET CONTROL FRESHWATER MODEL  
FLUSH  
CONTROL  
PANEL  
Solenoid Valve  
orange  
fuse/Breaker  
black  
red  
red  
black  
black  
To EST  
Discharge Pump  
Panel  
BATT  
Control Box  
Fig. 18 WIRING FOR ME TOILET CONTROL WITH REMOTE PUMP  
pump  
black  
orange  
Relay  
FLUSH  
CONTROL  
PANEL  
red  
red  
red  
black  
fuse/Breaker  
black  
RED  
To EST  
Discharge Pump  
Panel  
BATT  
Control Box  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D. Connect Hoses and wiring to toilet  
Fig. 19  
5. Route wire from control per wiring diagrams.  
6. Install seat. I nstall discharge support strap between  
seat nut and the bowl per Fig. 19A.  
7. Install toilet in place, connect hoses and wireplugs.  
(see Fig. 19)  
Caution: Do not pull on the discharge hose to avoid  
kinking  
Fig. 19A  
Discharge support strap  
Fig. 20  
E. Mount toilet  
8. Install mounting bushings, bolts. (See Fig. 20)  
9. Tighten bolts being careful to not overtighten (Do  
not exceed 30 inch lb. when tightening)  
10. Install caps over mounting bolts.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
WARNING: HAZARD OF ELECTRIC SHOCK - Before beginning any work on the toilet, be sure that all power  
totheunithasbeenturnedoff.  
WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before work-  
ingontoilet.  
NOTE:  
The following information reflects the most probable causes and solutions to problems although not  
every possible cause and solution is provided.  
Any questions regarding servicing or operation of the Marine Elegance should be directed to our Technical Support  
Department in Millville, NJ or Ft. Lauderdale, FL. Please have model and serial number available before calling.  
PROBLEM  
POSSIBLE CAUSE  
SOLUTION  
1. Poor pumpout, especially  
solids.  
1A. Cloggeddischargeline.  
1A. Besuredischargeseacockisopen. Clearline, remove  
clog.  
1B. Plumbing restrictions, bends and ells.  
1C. Clogged vents.  
1D. Mineral buildup in hoses and fittings.  
1E. Low voltage.  
1B. Replumb to eliminate bends and ells.  
1C. Clean holding tank vent and vented loop vents  
1D. Cleanorreplaceaffectedparts.Replacehoseifneeded.  
1E. Check voltage at toilet while toilet is running. If  
less than nominal voltage of toilet (12 or 24), check  
condition of batteries and wire sizes. Check terminals  
and wire connections for corrosion (heat at terminals  
andjunctionsindicatesabadorcorrodedconnection).  
2. Poorwaterflow, especially  
at front of bowl (or no wa-  
ter flow).  
2A. Toilet not level.  
2B. Restriction in intake line.  
2C. Pump sucking air.  
2A. Raise rear of toilet; check with level.  
2B. Be sure seacock is open. Clear line-remove clog.  
2C. Check all connections from intake thru-hull to intake  
pump to be sure no air leaks are present.  
2D. See1E,above.  
2D. Low voltage.  
2E. Clogged strainer.  
3A. “Marine life” lodged in rim of bowl.  
2E. Remove or Clear debris from strainer.  
3A. Removeandflushbowlwithpressurehosetoremove  
all material. Install strainer in intake line to avoid re-  
currence.  
3. Foulodorsfromtoiletarea.  
4. Bowl fills while underway.  
3B. Permeateddischargehose.  
3C. Sewage remaining in discharge line.  
3B. Replace hose with Raritan sanitation hose (#SH).  
3C. Flush toilet longer; replace hose if permeated; reroute  
hose making a shorter run if possible.  
4A. Close intake, then discharge seacock to determine  
which is causing problem. If discharge, be sure the  
vent or vented loop is clean. If intake, there is too  
muchpressureonseacock;contactRaritanTechnical  
Support.  
4A. Pressurebuildupatseacocks.  
5. Water leaking from under  
unit.  
5A. Leaking Bowl Throat adapter.  
5B. Leak at shaft seal.  
5A. Tightenadapterclamps.  
5B. Check seal and motor shaft.  
5C. Leak from bowl spud.  
5C. Checkandreseatbowlgrommet  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Marine Elegance PARTS LIST  
162135 Cone Seal  
162225 O-Ring  
162305 Lower Housing includes #162315  
221100 Toilet Bowl,standard, angled, White(1)  
221100A Toilet bowl Bone(1)  
2210012 Discharge Pump Assembly (1)  
221012 MOTOR: 12 VDC (1)  
221024 MOTOR: 24V DC (1)  
162310 Diaphragm includes #162315  
162315 Piston (4)  
162320 Piston Seat (4) includes #162315  
162325A Bearing Plate Assembly includes #162315  
162405 3/4" Hose Barb - 90° Fitting  
162410 3/4" Hose Barb - Straight Fitting (2)  
221105 O-RING (1)  
221110 Discharge Pump Seal Plate (1)  
221115 Discharge Pump Macerator Housing(1)  
221120 Bowl Throat Adapter (1)  
221125 Bowl Throat Adapter Clamp (small)(1)  
221130 Bowl Throat Adapter Clamp - Large (1)  
221135 JOKER VALVE (Custom) (2)  
221140 Discharge Hose (Custom)(1)  
221145 Discharge Adapter Fitting(1)  
221150 Uni Seal 1/2” (1)  
221155 Discharge Pump Mounting Bracket(1)  
221156 Discharge Mtg Bracket Straight Back Model  
221160 Discharge Hose Clamp - Small (1)  
221165 Discharge Hose Clamp - Large (1)  
221170 Discharge hose strap(not shown)  
221175 L bolts2(2) ( not shown)  
162415  
162420  
162425  
F005  
Plug Fitting  
Fitting Clip (3)  
Fitting O-Ring (4)  
Set Screw  
F172  
F144  
Piston Fastener (4)  
Mounting Bolt Washer (4)  
F162VT Mounting Bolt  
F199  
1108A  
Optional:  
Bushing  
Nut  
190601 Fresh water strainer  
221210 Bowl Mounting Bushing (2)  
221215 Bowl Mounting Bushing Cap (2)  
221300 Vacuum Breaker Assembly 1  
221325 Vacuum Breaker Seal Washer (1)  
221330 Vacuum Breaker O-Ring (#16)(1)  
221351 Water Solenoid Valve (12V)(1)  
221352 Water solenoid valve (24V)(1)  
221355 Water Line Adapter (1)  
163000 Raw water strainer  
NOT SHOWN;  
221101 Toilet Bowl ,Standard,Straight White  
231101 Toilet Bowl Tall Straight White  
231100 Toilet Bowl TallAngled White  
Note: add suffics “A “for bone  
1245  
1245A Seat and cover , Bone  
214** Relay  
Seat and cover, white  
221335 1/2" Hose 2.25" L (1)  
221340 1/2" Clamps (2)  
31-102 Motor Shaft Seal  
31-114 Lock Nut 10-32 W/Nylon (3)  
CH20B #10 Lock washer (not shown)  
Control parts (not shown):  
SSFC02 Smart Control Box  
SSFC 03 Smart wall panel  
SSFC04 Cable  
F321  
Fender washer (not shown)  
F186VT Bowl Mounting Screw: (2)  
F187VT Bowl Mounting Screw (1)  
31-603 Cable  
For Momentary Multifunction control after 02/10  
221549 Momentary Multifunction control box  
221524 Momentary Multifinction Bazel White  
221543 Momentary Multifinction wall panel  
221545 Cable for Momentary Multifunctin control  
F188  
Well Nut (2)  
F189 Deck Mounting (3)  
F193VT  
F195  
F196 Front mounting snap cap (1)  
M23A Lockwasher  
166000 Remote pump complete 12v  
166100 Remote pump complete 24V  
1660** Motor, raw water pump  
161115 Impeller  
Pump Mounting (1)  
Front mounting washer (1)  
Repair kits:  
DIAPUMPRK inlet pump repair kit  
162400 Fittings and O-rings for inlet pump  
166000 Diaphragm pump complete 12V  
166100 Diaphragm pump complete 24v  
MERK Discharge pump repair kit  
161123 Macerator Blade  
* Specify DC Voltage (12, 24, 32)  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
221300  
221150  
221340(2)  
221335  
221351(12V)  
221352(24V)  
221100  
221140  
221165  
221146  
221155  
F193  
221135(2)  
221145  
221160  
M23A  
1108A  
221105  
221110  
F195  
F187VT  
F196  
221215  
F199  
221115  
221210  
31-102 2210**  
161115  
221130 221125  
221120  
F186VT  
161123  
Recommended  
Seawater strainer  
freshwaterstrainer  
FIG 21  
rine Elegance Exploded Parts View  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
LIMITED WARRANTY  
RaritanEngineeringCompanywarrantstotheoriginalpurchaserthatthisproductisfreeofdefects  
inmaterialsorworkmanshipforaperiodofoneyearfromtheproduct’sdateofpurchase. Should  
this product prove defective by reason of improper workmanship and/or materials within the  
warrantyperiod,Raritanshall,atitssoleoption,repairorreplacetheproduct.  
1. TOOBTAINWARRANTYSERVICE,Consumermustdelivertheproductprepaid,togetherwith  
adetaileddescriptionoftheproblem,toRaritanat530OrangeSt.,Millville,N.J.08332,or3101SW  
2ndAve.Ft.Lauderdale,FL33315. Whenrequestingwarrantyservice,purchasermustpresenta  
salessliporotherdocumentwhichestablishesproofofpurchase.THERETURNOFTHEOWNER  
REGISTRATIONCARDISNOTACONDITIONPRECEDENTOFWARRANTYCOVERAGE.  
However,pleasecompleteandreturntheownerRegistrationCardsothatRaritancancontactyou  
shouldaquestionofsafetyarisewhichcouldaffectyou.  
2. THISWARRANTYDOESNOTCOVERdefectscausedbymodifications,alterations,repairsor  
serviceofthisproductbyanyoneotherthanRaritan;defectsinmaterialsorworkmanshipsupplied  
byothersintheprocessofinstallationofthisproduct;defectscausedbyinstallationofthisproduct  
otherthaninaccordancewiththemanufacturer’srecommendedinstallationinstructionsorstandard  
industryprocedures;physicalabuseto,ormisuseof,thisproduct. Thiswarrantyalsodoesnotcover  
damagestoequipmentcausedbyfire,flood,externalwater,excessivecorrosionorActofGod.  
3. ANYEXPRESSWARRANTYNOTPROVIDEDHEREIN,ANDANYREMEDYFORBREACH  
OFCONTRACTWHICHBUTFORTHISPROVISIONMIGHTARISEBYIMPLICATIONOR  
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED  
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A  
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES  
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A  
TERMOFONEYEAR. SOMESTATESDONOTALLOWLIMITATIONSONHOWLONGA  
LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.  
4. UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY  
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER  
ARISINGOUTOFBREACHOFWARRANTY, BREACHOFCONTRACT,OROTHERWISE.  
SOMESTATESDONOTALLOWTHEEXCLUSIONORLIMITATIONOFINCIDENTALOR  
CONSEQUENTIALDAMAGES,SOTHEABOVELIMITATIONOREXCLUSIONMAYNOT  
APPLY TO YOU.  
5. Nootherpersonorentityisauthorizedtomakeanyexpresswarranty,promiseoraffirmationoffact  
or to assume any other liability on behalf of Raritan in connection with its products except as  
specificallysetforthinthiswarranty.  
6. Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrightswhichvaryfrom  
statetostate.  
530 Orange Street, Millville, NJ 08332 USA  
Telephone: 856-825-4900 FAX: 856-825-4409  
Southern Office and Plant:  
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA  
Telephone: 954-525-0378 FAX: 954-764-4370  
L460 0610vkm  
Specifications Subject to Change Without Notice  
Printed in U.S.A.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Pyramid Car Audio DVD Player PDVD44 User Guide
Radio Shack Cordless Telephone ET 548 User Guide
RIDGID Air Compressor OL50135W User Guide
Roland Electronic Keyboard RP301 User Guide
Rosen Entertainment Systems GPS Receiver 7002 User Guide
Samson Car Speaker RSX110 User Guide
Samsung Air Conditioner SC18ZV User Guide
Sanyo Projector PLC XL51 User Guide
Savin Printer FAX3740 User Guide
Schumacher Power Supply PST 200 User Guide