Porter Cable Nail Gun DA250B User Manual

ESPAÑOL: PÁGINA 13  
FRANÇAISE : PAGE 25  
FINISH NAILER  
Instruction  
manual  
MODEL DA250B  
IMPORTANT  
Please make certain that the person who is  
to use this equipment carefully reads and  
understands these instructions before  
starting operations.  
To learn more about Porter-Cable  
visit our website at:  
The Model and Serial No. plate is located on the main  
housing of the tool. Record these numbers in the  
spaces below and retain for future reference.  
Model No. ______________________________________  
Type ___________________________________________  
Serial No._______________________________________  
Copyright © 2004 Porter-Cable Corporation  
Part No. 903898 - 04-01-04  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY GUIDELINES / DEFINITIONS  
This manual contains information that is important for you to know and under-  
stand. This information relates to protecting YOUR SAFETY and PREVENTING  
EQUIPMENT PROBLEMS. To help you recognize this information, we use the  
symbols below. Please read the manual and pay attention to these sections.  
indicates an imminently hazardous situation which, if not avoided,  
will result in death or serious injury.  
indicates a potentially hazardous situation which, if not avoided,  
could result in death or serious injury.  
indicates a potentially hazardous situation which, if not avoided,  
may result in minor or moderate injury.  
used without the safety alert symbol indicates potentially  
hazardous situation which, if not avoided, may result in property  
damage.  
IMPORTANT SAFETY INSTRUCTIONS  
SAVE THESE INSTRUCTIONS!  
Improper operation or maintenance of this product could  
result in serious injury and property damage. Read and understand all  
warnings and operating instructions before using this tool. When using  
pneumatic tools, basic safety precautions should always be followed to  
reduce the risk of personal injury. For additional information visit our  
Additional Information regarding the safe and proper operation of air  
nailer and fastener tools (i.e. a safety video) is available from the  
International Staple, Nail and Tool Association (ISANTA)  
operation of power tools (i.e. a safety video) is available from the Power  
Tool Institute, 1300 Sumner Avenue, Cleveland, OH 44115-2851  
from the National Safety Council, 1121 Spring Lake Drive, Itasca, IL  
60143-3201, the American National Standards Institute ANSI 01.1Safety  
Requirements for Woodworking Machines, and the U.S. Department of  
Labor regulations.  
READ AND FOLLOW ALL INSTRUCTIONS.  
There are certain applications for which this tool was  
designed. Porter-Cable strongly recommends that this tool NOT be modified  
and/or used for any application other than for which it was designed. If you  
have any questions relative to its application DO NOT use the tool until you  
have written Porter-Cable and we have advised you.  
Technical Service Manager  
Porter-Cable Corporation  
4825 Highway 45 North  
Jackson, TN 38305  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL SAFETY RULES  
1. Read and understand tool labels and  
Fig. 1  
manual. Failure to follow warnings could  
result in DEATH or SERIOUS INJURY. Fig. 1.  
2. Operator and others in work area MUST  
wear safety glasses with side shields.  
These safety glasses must conform to ANSI  
Z87.1 requirements (approved glasses have  
“Z87” printed or stamped on them). Fig. 2.  
Fig. 2  
3. Keep fingers AWAY from trigger when  
not driving fasteners to avoid accidental  
firing. Never carry tool with finger on  
trigger. In "contact actuation mode", tool  
will fire a fastener if tool is bumped.  
Fig. 3  
4. Choice of triggering method is  
important. Check manual for triggering  
options. See “Using the Tool with Different  
Triggering Options” section of this manual.  
5. Never point tool at yourself or others  
in work area. Serious injury or death may  
occur if the tool is activated. Fig. 3  
Fig. 4  
6. Never use oxygen or other bottled  
gasses. Explosion will occur. Never use  
combustible gases or any other reactive  
gas as a power source for this tool:  
explosion and serious personal injury will  
result. Fig. 4.  
Fig. 5  
7. Wear ear protection to safe-guard  
against possible hearing loss. Ear  
protection equipment must conform to ANSI  
S3.19 requirements. Fig. 5.  
Fig. 6  
8. Use clean, dry, regulated, com-  
pressed air at 70 to 120 PSI, (4.8 to 8.3  
BAR). Fig. 6.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Do not connect tool to pressure which  
potentially exceeds 200 PSI (13.7 BAR).  
10. All air line components (hoses,  
connectors, filters, regulators, etc.) must  
be rated for a maximum working pressure  
of at least 150 PSI (10.3 BAR) or 150% of  
the maximum system pressure, which ever  
is greater.  
11. Connect tool to air supply hose with a  
coupling that automatically removes all  
pressure from the tool when the coupling is  
disconnected. Fig. 7.  
Fig. 7  
Fig. 8  
12. Disconnect tool from air supply hose  
before doing tool maintenance, clearing a  
jammed fastener, leaving work area, moving  
tool to another location, or handing the tool  
to another person. Fig. 7.  
13. Never use a tool that is leaking air, has  
missing or damaged parts, or requires  
repair. Make sure all screws and caps are  
securely tightened. Fig. 8.  
Fig. 9  
14. Never use tool if safety, trigger or  
springs are inoperable, missing or  
damaged. Do not alter or remove safety,  
trigger, or springs. Make daily inspections  
for free movement of trigger and safety  
mechanism. Fig. 8.  
15. Do not use tool without safety  
warning label. If label is missing, damaged  
or unreadable, contact your Porter-Cable  
Service Center for a replacement. Fig. 9.  
16. Only use parts, fasteners and  
accessories approved by Porter-Cable.  
17. Connect tool to air supply before  
loading fasteners, to prevent a fastener  
from being fired during connection. The tool  
driving mechanism may cycle when tool is  
connected to the air supply. Fig. 10.  
Fig. 10  
Fig. 11  
18. Always assume the tool contains  
fasteners. No horseplay. Respect the tool  
as a working implement. Fig. 11.  
19. Operator and bystanders should wear  
hard hats to safeguard against possible  
injuries. Fig. 12.  
20. Do not load fasteners with trigger or  
safety depressed, to prevent unintentional  
firing of a fastener. Fig. 13  
Fig. 12  
Fig. 13  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
21. Remove finger from trigger when not  
driving fasteners. Never carry tool with finger  
on trigger. In “Contact Actuation Mode” tool  
will fire a fastener if safety is bumped while  
trigger is depressed. Fig. 14.  
Fig. 14  
22. Do not overreach. Keep proper footing  
and balance at all times when using or  
handling the tool.  
23. Fire fasteners into work surface only:  
never into materials too hard to penetrate.  
Fig. 15.  
Fig. 15  
24. Grip tool firmly to maintain control  
while allowing tool to recoil away from  
work surface as fastener is driven. In  
“Contact Actuation Mode” if safety element  
is allowed to recontact work surface before  
trigger is released an unwanted fastener will  
be fired.  
Fig. 16  
25. Do not drive fasteners on top of other  
fasteners, or with the tool at too steep an  
angle: the fasteners can ricochet causing  
personal injury. Fig. 15.  
26. Do not drive fasteners close to the  
edge of the workpiece. The workpiece is  
likely to split allowing the fastener to fly free  
or ricochet causing personal injury. Fig. 16.  
Fig. 17  
27. FOR TOOLS USED IN CONTACT  
ACTUATION MODE, Do not use on  
scaffoldings or ladders or for tasks in  
which changing location involves the use of  
scaffoldings, stairs, ladders, and the like. Do  
not use for specific tasks such as closing  
boxes or crates or fitting transportation  
safety systems on vehicles and wagons.  
Fig. 17.  
TECHNICAL SPECIFICATIONS  
Noise level . . . . . . . . . . . . . . . . . .  
Typical Mean  
A - Weighted sound impulse . . .  
power level . . . . . . 101 dBA  
P - Emission sound pressure  
pressure level . . . . . . 93 dBA  
effective Acceleration . . . . 5.4 m/s2  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
EMPLOYER’S RESPONSIBILITIES  
Employer must enforce compliance with the safety warnings and all other  
instructions contained in this manual.  
Keep this manual available for use by all people assigned to use this tool.  
For personal safety and proper operation of this tool, read and understand  
tool labels and manual. Failure to follow warnings could result in DEATH or  
SERIOUS INJURY. Read and follow all of these instructions carefully.  
FUNCTIONAL DESCRIPTION  
Porter-Cable Model DA250B is a heavy duty pneumatic finish nailer. It is  
designed to install 15 ga. finish nails of various lengths from 11/4" to 21/2"  
long.  
Use approved Porter-Cable fasteners only.  
POWER SOURCE  
This tool is designed to operate on clean, dry, compressed air at regulated  
pressures between 70 and 120 PSI (Pounds per Square Inch)(4.8 to 8.3 BAR)  
.
The preferred system would include a filter, a pressure regulator, and an  
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is  
ideal.  
All compressed air contains moisture and other contaminates that are  
detrimental to internal components of the tool. An air line filter will remove  
most of these contaminates and significantly prolong the life of the tool. If an  
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil  
into the tool’s air inlet at the beginning of each workday.  
1
3
The tool is equipped with a  
/
4" male “quick connector”. A /8" male “quick  
connector” is available from Porter-Cable and may be used in situations where  
1
a
/4" supply line is not available. The tool must always be connected to the air  
supply with a coupling such that all pressure is removed from the tool when the  
coupling is disconnected.  
PREPARING THE TOOL  
1. After reading and understanding this entire manual, connect tool to  
air supply (Fig. 18).  
2. Orient a strip of approved fasteners with points down (A) Fig. 19, align,and  
insert into the magazine “T” slot points first.  
Do not load fastener strip into magazine backwards.  
A
Fig. 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fig. 19  
7
3. Observe fastener icon (A) Fig. 19A. Insert fasteners (B) Fig. 19A with  
points down (C) Fig. 19A. Slide fasteners forward to the front of the  
magazine. The magazine will hold two full strips of fasteners.  
IMPORTANT: Fasteners must point in the same direction as they will be  
driven.  
4. Feed the strip of fasteners into the magazine (“T” slot), until they are past  
the spring (A) Fig. 20.  
5. Pull the follower (B) Fig. 21, all the way to the rear of the magazine and  
release. The follower will apply pressure to the strip of nails to feed it into the  
driving mechanism.  
6. Adjust directional exhaust deflector (A) Fig. 22, so that the exhaust air  
blast will be directed away from the operator. The exhaust deflector provides  
seven detented positions for directing the exhaust blast away from the  
operator. Grasp the deflector and rotate it to the desired position for the  
current application.  
A
A
B
C
Fig. 20  
Fig. 19A  
B
A
Fig. 21  
Fig. 22  
S
Fig. 23  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATING INSTRUCTIONS  
USING THE TOOL WITH DIFFERENT TRIGGERING OPTIONS  
Complete all steps of PREPARING THE TOOL before using the tool.  
This tool is shipped from the factory with a “single sequential actuation”  
trigger which will limit the tool to firing method number 1 only.  
A “contact actuation” trigger is available. The “contact actuation” trigger  
allows the tool to be fired in either of two methods described below;  
1. [SINGLE SEQUENTIAL ACTUATION TRIGGER]: To fire, grip tool firmly  
to maintain control, position nose of tool onto work surface, push the tool  
firmly against work surface to depress safety (S) Fig. 23, and squeeze  
trigger to fire a fastener. Allow tool to recoil away from work surface as  
fastener is driven. This “single sequential actuation” method provides the  
most accurate fastener placement.  
-OR-  
2. [CONTACT ACTUATION TRIGGER]: To fire, grip tool firmly to maintain  
control, squeeze and hold trigger, push the tool firmly against work surface.  
Allow tool to recoil away from work surface as fastener is driven. If safety  
element is allowed to recontact work surface before trigger is released an  
unwanted fastener will be fired. The tool will fire a fastener each time the  
safety is depressed. This method is known as “contact actuation” and  
allows very fast repetitive fastener placement.  
IMPORTANT: A “contact actuation” trigger is available free-of-charge by  
calling 1-800-321-9443 in the United States and Canada or 001-731-660-  
9374 outside the United States and Canada, and providing tool model and  
serial number. For identification purposes: the contact actuation trigger is  
black and the single sequential actuation trigger is red.  
Disconnect tool from air supply before performing  
maintenance, clearing a jammed fastener, leaving work  
area, moving tool to another location, or handing the tool  
to another person.  
Clean and inspect tool daily. Carefully check for proper  
operation of trigger and safety mechanism. Do Not use the tool unless  
both the trigger and the safety mechanism are functional, or if the tool is  
leaking air or needs any other repair.  
The depth to which a fastener is driven is controlled by the depth adjustment  
knob (A) Fig. 24. The depth of drive is factory adjusted to a nominal setting.  
Test fire a fastener and check depth. If a change is desired, rotate the  
adjustment knob (A) Fig. 24. The adjustment knob has detents every 1/4 turn.  
Rotate the knob (A) Fig. 24 clockwise to increase the depth of drive, rotate  
the knob counterclockwise to decrease the  
depth of drive. Test fire another fastener and  
check depth. Repeat as necessary to  
achieve desired results. The amount of air  
pressure required will vary depending on the  
size of the fastener and the material being  
fastened. Experiment with the air pressure  
setting to determine the lowest setting that  
will consistently perform the job at hand. Air  
A
pressure in excess of that required can  
cause premature wear and/or damage to the  
Fig. 24  
tool.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
A
A
Fig. 25  
Fig. 26  
A rubber nose cushion (A) Fig. 25, is provided to reduce marring of the work  
surface. The rubber cushion can be removed to provide increased depth-of-  
drive for toe-nailing applications. When not in use, a storage location is  
provided for the the rubber cushion on the magazine (A) Fig. 26.  
Disconnect tool from air supply before removing or  
re-installing rubber cushion.  
CLEARING A JAMMED FASTENER  
Disconnect tool from air supply.  
1. Remove any remaining fasteners from the nailer.  
A. Place finger in recess (A) Fig. 27, and push lever to release follower  
mechanism.  
B. Slide the follower to the end of the magazine (refer back to Fig. 21).  
C. Depress the lever (A) Fig. 28, to release follower mechanism, and slide  
all remaining fasteners out of the magazine.  
NOTE: Make sure tip (B) Fig. 28 clears nail strip.  
A
B
A
Fig. 28  
Fig. 27  
2. Open the quick release latch and hinge the fastener guide plate open (B)  
Fig. 29.  
3. Remove the jammed fastener (see Fig. 30).  
4. Close the fastener guide plate and secure with the quick release latch.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B
Fig. 30  
Fig. 29  
MAINTENANCE  
CLEAN AND INSPECT DAILY  
Disconnect tool from air supply before cleaning and  
inspection. Correct all problems before placing the tool back in use.  
Wipe tool clean and inspect for wear or damage. Use non-flammable  
cleaning solutions to wipe exterior of tool only if necessary. DO NOT SOAK  
tool with cleaning solutions. Such solutions can damage internal parts.  
Inspect trigger and safety mechanism to assure system is complete and  
functional: no loose or missing parts, no binding or sticking parts.  
Keep all screws tight. Loose screws can cause personal injury or damage  
tool.  
If tool is used without an in-line oiler: place 5 or 6 drops of Porter-Cable Air  
Tool Oil into the air inlet of the tool at the beginning of each workday.  
SERVICE AND REPAIRS  
All quality tools will eventually require servicing or replacement of parts due  
to wear from normal use. These operations should ONLY be performed by  
either an AUTHORIZED PORTER-CABLE SERVICE STATION or a PORTER-  
CABLE•DELTA FACTORY SERVICE CENTER. All repairs made by these  
agencies are fully guaranteed against defective material and workmanship.  
We cannot guarantee repairs made or attempted by anyone other than these  
agencies.  
Should you have any questions about your tool, feel free to write us at any  
time. In any communications, please give all information shown on the  
nameplate of your tool (model number, type, serial number, etc.).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Disconnect tool from air supply before performing any Service  
Procedure.  
SYMPTOM  
PROBLEMS  
SOLUTIONS  
1. Air leak near top of  
tool or in trigger area.  
Loose screws.  
Worn or damaged  
o-rings or seals.  
Tighten screws.  
Install Overhaul Kit.  
2. Tool does nothing or  
operates sluggishly.  
Inadequate air supply.  
Inadequate lubrication.  
Worn or damaged  
o-rings or seals.  
Verify adequate air supply.  
Put 5 or 6 drops of oil into air inlet.  
Install Overhaul Kit.  
3. Air leak near bottom  
of tool.  
Loose screws.  
Worn or damaged  
o-rings or bumper.  
Tighten screws.  
Install Overhaul Kit.  
4. Tool jams frequently.  
Incorrect fasteners.  
Verify approved fasteners of  
correct size.  
Damaged fasteners.  
Magazine or nose  
screws loose.  
Replace w/undamaged fasteners.  
Tighten screws.  
Magazine is dirty.  
Clean magazine.  
Driver is worn or damaged. Install “DRIVER” Maintenance Kit.  
5. Other.  
Contact a Porter-Cable  
Service Facility.  
ACCESSORIES  
A complete line of accessories is available from your Porter-Cable • Delta  
Supplier, Porter-Cable • Delta Factory Service Centers, and Porter-Cable  
Authorized Service Stations. Please visit our Web Site www.porter-cable.com  
for a catalog or for the name of your nearest supplier.  
Since accessories, other than those offered by Porter-  
Cable • Delta, have not been tested with this product, use of such  
accessories could be hazardous. For safest operation, only Porter-Cable  
• Delta recommended accessories should be used with this product.  
PORTER-CABLE LIMITED  
ONE YEAR WARRANTY  
Porter-Cable warrants its nailing and stapling tools for a period of one year from the date of original  
purchase. We will repair or replace at our option, any part or parts of the product and accessories  
covered under this warranty which, after examination, proves to be defective in workmanship or  
material during the warranty period. For repair or replacement return the complete tool or accessory,  
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.  
Proof of purchase may be required. This warranty does not apply to O-rings and Driver Blades or to  
repair or replacement required due to misuse, abuse, normal wear and tear or repairs attempted or  
made by other than our Service Centers or Authorized Service Stations.  
ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND  
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE  
OF PURCHASE.  
To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,  
4825 Highway 45 North, Jackson, Tennessee 38305; Attention: Product Service. THE FOREGOING  
OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY IMPLIED WARRANTY  
AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR ANY INCIDENTAL  
OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied  
warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above  
limitation or exclusion may not apply to you.  
This warranty gives you specific legal rights and you may also have other legal rights which vary  
from state to state.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PORTER-CABLE • DELTA SERVICE CENTERS  
(CENTROS DE SERVICIO DE PORTER-CABLE • DELTA)  
(CENTRE DE SERVICE PORTER-CABLE • DELTA)  
Parts and Repair Service for Porter-Cable  
(Obtenga Refaccion de Partes o Servicio para su Herramienta en los Siguientes Centros de Porter-Cable  
(Locations où vous trouverez les pièces de rechange nécessaires ainsi qu’un service d’entretien)  
Delta Power Tools are Available at These Locations  
Delta)  
Cleveland 44125  
8001 Sweet Valley Drive  
Unit #19  
Phone: (216) 447-9030  
Fax: (216) 447-3097  
ARIZONA  
MINNESOTA  
Minneapolis 55429  
5522 Lakeland Avenue North  
Phone: (763) 561-9080  
Fax: (763) 561-0653  
GEORGIA  
Tempe 85282 (Phoenix)  
2400 West Southern Avenue  
Suite 105  
Phone: (602) 437-1200  
Fax: (602) 437-2200  
Forest Park 30297 (Atlanta)  
5442 Frontage Road,  
Suite 112  
Phone: (404) 608-0006  
Fax: (404) 608-1123  
OREGON  
MISSOURI  
Portland 97230  
CALIFORNIA  
North Kansas City 64116  
1141 Swift Avenue  
Phone: (816) 221-2070  
Fax: (816) 221-2897  
ILLINOIS  
4916 NE 122 nd Ave.  
Phone: (503) 252-0107  
Fax: (503) 252-2123  
Ontario 91761 (Los Angeles)  
3949A East Guasti Road  
Phone: (909) 390-5555  
Fax: (909) 390-5554  
Addison 60101 (Chicago)  
400 South Rohlwing Rd.  
Phone: (630) 424-8805  
Fax: (630) 424-8895  
PENNSYLVANIA  
St. Louis 63119  
Willow Grove 19090 (Philadelphia)  
520 North York Road  
Phone: (215) 658-1430  
Fax: (215) 658-1433  
7574 Watson Road  
Phone: (314) 968-8950  
Fax: (314) 968-2790  
Woodridge 60517 (Chicago)  
2033 West 75th Street  
Phone: (630) 910-9200  
Fax: (630) 910-0360  
San Diego 92111  
7638 Clairemnot Blvd.  
Phone: (858) 277-9595  
Fax: (858) 277-9696  
NEW YORK  
TEXAS  
Flushing 11365-1595 (N.Y.C.)  
175-25 Horace Harding Expwy.  
Phone: (718) 225-2040  
Fax: (718) 423-9619  
MARYLAND  
San Leandro 94577 (Oakland)  
3039 Teagarden Street  
Phone: (510) 357-9762  
Fax: (510) 357-7939  
Carrollton 75006 (Dallas)  
1300 Interstate 35 N, Suite 112  
Phone: (972) 446-2996  
Fax: (972) 446-8157  
Elkridge 21075 (Baltimore)  
7397-102 Washington Blvd.  
Phone: (410) 799-9394  
Fax: (410) 799-9398  
NORTH CAROLINA  
Charlotte 28270  
9129 Monroe Road, Suite 115  
Phone: (704) 841-1176  
Fax: (704) 708-4625  
COLORADO  
Houston 77043  
4321 Sam Houston Parkway, West  
Suite 180  
Phone: (713) 983-9910  
Fax: (713) 983-6645  
MASSACHUSETTS  
Arvada 80003 (Denver)  
8175 Sheridan Blvd., Unit S  
Phone: (303) 487-1809  
Fax: (303) 487-1868  
Franklin 02038 (Boston)  
Franklin Industrial Park  
101E Constitution Blvd.  
Phone: (508) 520-8802  
Fax: (508) 528-8089  
OHIO  
FLORIDA  
WASHINGTON  
Columbus 43214  
4560 Indianola Avenue  
Phone: (614) 263-0929  
Fax: (614) 263-1238  
Davie 33314 (Miami)  
4343 South State Rd. 7 (441)  
Unit #107  
Phone: (954) 321-6635  
Fax: (954) 321-6638  
Auburn 98001(Seattle)  
3320 West Valley HWY, North  
Building D, Suite 111  
Phone: (253) 333-8353  
Fax: (253) 333-9613  
MICHIGAN  
Madison Heights 48071 (Detroit)  
30475 Stephenson Highway  
Phone: (248) 597-5000  
Fax: (248) 597-5004  
Tampa 33609  
4538 W. Kennedy Boulevard  
Phone: (813) 877-9585  
Fax: (813) 289-7948  
Authorized Service Stations are located in many large cities. Telephone 800-487-8665 or 731-541-6042 for assistance locating one. Parts and  
accessories for Porter-Cable Delta products should be obtained by contacting any Porter-Cable Delta Distributor, Authorized Service  
Center, or Porter-Cable Delta Factory Service Center. If you do not have access to any of these, call 888-848-5175 and you will be directed to  
the nearest Porter-Cable Delta Factory Service Center. Las Estaciones de Servicio Autorizadas están ubicadas en muchas grandes ciudades.  
Llame al 800-487-8665 ó al 731-541-6042 para obtener asistencia a fin de localizar una. Las piezas y los accesorios para los productos Porter-  
Cable Delta deben obtenerse poniéndose en contacto con cualquier distribuidor Porter-Cable Delta, Centro de Servicio Autorizado o Centro  
de Servicio de Fábrica Porter-Cable Delta. Si no tiene acceso a ninguna de estas opciones, llame al 888-848-5175 y le dirigirán al Centro de  
Servicio de Fábrica Porter-Cable Delta más cercano. Des centres de service agréés sont situés dans beaucoup de grandes villes. Appelez au  
800-487-8665 ou au 731-541-6042 pour obtenir de l’aide pour en repérer un. Pour obtenir des pièces et accessoires pour les produits Porter-  
Cable  
Delta, s’adresser à tout distributeur Porter-Cable  
Delta, centre de service agréé ou centre de service d’usine Porter-Cable  
Delta. Si  
vous n’avez accès à aucun de ces centres, appeler le 888-848-5175 et on vous dirigera vers le centre de service d’usine Porter-Cable  
Delta le  
plus proche.  
CANADIAN PORTER-CABLE DELTA SERVICE CENTERS  
QUÉBEC  
ALBERTA  
MANITOBA  
1515 Ave.  
Bay 6, 2520-23rd St. N.E.  
Calgary, Alberta  
T2E 8L2  
1699 Dublin Avenue  
Winnipeg, Manitoba  
R3H 0H2  
St-Jean Baptiste, Suite 160  
Québec, P.Q.  
G2E 5E2  
Phone: (418) 877-7112  
Fax: (418) 877-7123  
Phone: (403) 735-6166  
Fax: (403) 735-6144  
Phone: (204) 633-9259  
Fax: (204) 632-1976  
BRITISH COLUMBIA  
8520 Baxter Place  
Burnaby, B.C.  
V5A 4T8  
Phone: (604) 420-0102  
Fax: (604) 420-3522  
ONTARIO  
1447, Begin  
St-Laurent, (Mtl), P.Q.  
H4R 1V8  
Phone: (514) 336-8772  
Fax: (514) 336-3505  
505 Southgate Drive  
Guelph, Ontario  
N1H 6M7  
Phone: (519) 767-4132  
Fax: (519) 767-4131  
The following are trademarks of PORTER-CABLE  
DELTA (Las siguientes son marcas registradas de PORTER-CABLE  
DELTA S.A.) (Les  
marques suivantes sont des marques de fabriquant de la PORTER-CABLE  
DELTA): Auto-Set®, BAMMER®, B.O.S.S.®, Builder’s Saw®,  
Contractor’s Saw®, Contractor’s Saw II™, Delta®, DELTACRAFT®, DELTAGRAM™, Delta Series 2000™, DURATRONIC™, Emc²™, FLEX®, Flying  
Chips™, FRAME SAW®, Grip Vac™, Homecraft®, INNOVATION THAT WORKS®, Jet-Lock®, JETSTREAM®, ‘kickstand®, LASERLOC®, MICRO-  
SET®, Micro-Set®, MIDI LATHE®, MORTEN™, NETWORK™, OMNIJIG®, POCKET CUTTER®, PORTA-BAND®, PORTA-PLANE®, PORTER-  
CABLE®&(design), PORTER-CABLE®PROFESSIONAL POWER TOOLS, PORTER-CABLE REDEFINING PERFORMANCE™, Posi-Matic®, Q-  
3®&(design), QUICKSAND®&(design), QUICKSET™, QUICKSET II®, QUICKSET PLUS™, RIPTIDE™&(design), SAFE GUARD II®, SAFE-LOC®,  
Sanding Center®, SANDTRAP®&(design), SAW BOSS®, Sawbuck™, Sidekick®, SPEED-BLOC®, SPEEDMATIC®, SPEEDTRONIC®, STAIR EASE®,  
The American Woodshop®&(design), The Lumber Company®&(design), THE PROFESSIONAL EDGE®, THE PROFESSIONAL SELECT®, THIN-  
LINE™, TIGER®, TIGER CUB®, TIGER SAW®, TORQBUSTER®, TORQ-BUSTER®, TRU-MATCH™, TWIN-LITE®, UNIGUARD®, Unifence®,  
UNIFEEDER™, Unihead®, Uniplane™, Unirip®, Unisaw®, Univise®, Versa-Feeder®, VERSA-PLANE® , WHISPER SERIES®,  
WOODWORKER’S CHOICE™.  
Trademarks noted with ™ and ® are registered in the United States Patent and Trademark Office and may also be registered in other countries.  
Las Marcas Registradas con el signo de ™ y ® son registradas por la Oficina de Registros y Patentes de los Estados Unidos y también pueden  
estar registradas en otros países. Marques déposées, indiquées par la lettre ™ et ®, sont déposées au Bureau des brevets d’invention et  
marques déposées aux Etats-Unis et pourraient être déposées aux autres pays.  
PC-0104-151  
Download from Www.Somanuals.com. All Manuals Search A  
P
n
r
d
int  
D
edowin  
n
U
lo.S  
a
.A  
d
.
.

Peavey Speaker 415 Sub User Manual
Pelco Pacemaker C2907M QS User Manual
Perlick Beverage Dispenser BC24 Series User Manual
Philips Clock Radio AJ 3040 00P User Manual
Philips MP3 Player WAS700 User Manual
Pioneer Industrial DVD Player DV 470 User Manual
Polk Audio Speaker PSW121 User Manual
Poulan Lawn Mower PRK17H42STB User Manual
Premier Mounts TV Mount 9533 004 001 07 User Manual
Presto Electric Pressure Cooker Electric Pressure Washer User Manual