Perlick Beverage Dispenser BC24 Series User Manual

INSTALLATION AND OPERATION INSTRUCTIONS  
FLAT TOP BOTTLE COOLER  
MODEL NOS.  
BC24 Series  
BC36 Series  
BC48 Series  
BC60 Series  
BC72 Series  
BC96 Series  
IMPORTANT INFORMATION  
Table of Contents  
Cabinet Specifications ..........................................2  
Installing  
This manual has been prepared to assist you in the  
installation of your Bottle Cooler and to acquaint you  
with its operation and maintenance.  
Uncrating and Inspection ................................3  
Plumbing .........................................................3  
Electrical..........................................................3  
Adjusting Partitions .........................................3  
Installing Casters and Legs.............................3  
Placing the Cabinet.........................................3  
Sealing to the Floor.........................................3  
Temperature Control .............................................4  
Cleaning the Cabinet ............................................4  
Wiring Diagram .....................................................5  
Replacement Parts ............................................6/7  
We dedicate considerable time to ensure that our  
products provide the highest level of customer  
satisfaction. If service is required, call Perlick at  
1-800-777-7267 or your dealer who can provide you  
with a list of qualified service agents. For your own  
protection, never return merchandise for credit with-  
out our approval.  
We thank you for selecting a Perlick product and  
assure you of our continuing interest in your  
satisfaction.  
IMPORTANT WARRANTY INFORMATION  
A Warranty card is enclosed that must be completed  
and mailed to the Perlick Corporation to register the  
warranty. If the card is not returned to Perlick, the  
warranty period will begin from the date the  
equipment is shipped from the factory.  
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069  
Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com  
Form No. Z2219  
Rev. 4.15.06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preparing the Cabinet – Flat Top Bottle Coolers  
Uncrating and Inspection  
Placing the Cabinet  
Remove all crating material before operating.  
Carefully inspect cabinet for hidden damage.  
If damage is discovered, file your claim immediately  
with the transport company. Perlick is not  
responsible for damage in transit.  
To assure maximum performance, fresh air must  
be allowed to circulate through the machinery  
compartment. It is important to allow at least two  
inches of clearance at the back or left end of the  
cabinet. Do not place anything in front of the  
cabinet that would obstruct air flow at these grilles.  
Do not place the unit in an unventilated small room.  
Plumbing  
CAUTION:  
No plumbing connections are required. Condensate  
from the cooling coil automatically evaporated  
through a condensate pan located in the  
condensing unit section.  
Removing the factory installed back clearance  
spacers without providing proper left side grill  
clearance for compressor air flow will void  
the warranty.  
Cabinet should be leveled.  
Electrical  
For sanitation purposes, it may be necessary to  
seal the base of the cabinet to the floor. This  
can be accomplished by laying a bead of silicone  
sealant along the base of the cabinet as shown  
by the figure below.  
The cabinet must be connected to a separately  
fused power source (see Electrical Specification  
Plate) and grounded in accordance with National  
and Local Electrical Codes.  
CAUTION: Do not attempt to operate the equipment  
on any other power source than that listed on the  
Electrical Specification Plate.  
Adjustable Partitions  
Perlick Bottle Coolers are provided with adjustable  
partitions which will accommodate various bottle  
sizes.  
CABINET  
Remove bottles and cans from their cases  
before placing in cooler to ensure proper  
air flow.  
BEAD SILICON  
SEALER (RTV)  
On 2’ and 3’ models keep air intake open for  
proper circulation.  
FLOOR  
Installing Casters or Legs (optional)  
Attach casters or legs to the cabinet bottom in holes  
provided. Use the supplied 14”–20 hex head self-  
tapping machine screws. If unit is tipped on its back  
for an extended period of time, wait 24 hours after  
unit is uprighted to plug the unit in.  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
Rev. 4.15.06  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
How To Operate – Flat Top Bottle Coolers  
Temperature Control  
Cleaning the Doors:  
An adjustable temperature control is located inside  
the Bottle Cooler on the evaporator fan panel  
assembly. It is factory set at “Normal” approximately  
38° F. Make adjustments as shown to attain the  
desired temperature.  
NOTE: A temperature setting that is too low will not  
allow enough condensing unit “off” time to maintain  
a frost-free coil.  
Doors should be periodically removed from the  
cabinet and inspected for a buildup of foreign  
materials, such as syrups, beer, etc. Buildups  
on the underside of the doors, along with the  
cabinet breaker strips on which they ride, will  
cause them to bind, and therefore, not function  
as designed. If dirty, these surfaces should be  
cleaned with a mild detergent and water and  
then coated with a silicone lubricating material.  
Aerosol silicone sprays can be obtained locally  
at most department or automotive stores.  
To remove doors:  
Colder Temperatures: Turn the adjusting  
screw clockwise (to the right).  
Warmer Temperatures: Turn the adjusting  
screw counterclockwise (to the left).  
Temperature Control “OFF”: Turn the  
adjusting screw completely counterclock-  
wise to the “O” position until a “click” is  
noted.  
With door closed, lift it upward by its handle and  
slide forward until door clears the cabinet top.  
Use the reverse procedure to reinstall the doors.  
Cleaning the Cabinet:  
Use a damp cloth with a mild detergent and  
water to clean the inside and outside of the  
cabinet. Dry thoroughly. Do not allow cleaning  
agents or large amounts of water to go down  
the drain. Use an acceptable stainless steel  
polish to clean all stainless steel surfaces.  
Never use steel wool or scouring pads to clean  
stainless steel.  
The condenser fan motor turns off and on with  
the compressor. The evaporator fan motor runs  
continuously.  
Cleaning the Condenser:  
The condenser (located behind the front  
grille) should be inspected every 30 days,  
and cleaned, if necessary. Failure to keep  
the condenser clean will cause a loss in  
condensing unit efficiency, or compressor  
failure.  
Avoiding Stainless Steel Corrosion  
Corrosion can be prevented by following product cautions, cleaning instructions and avoiding use of certain  
chemicals or objects which will cause stainless steel corrosion.  
STAINLESS STEEL ENEMY  
Steel wool or steel scouring pads  
Cherry/Orange/Olive juice  
Chlorine Bleach  
Sharp Objects  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
4
Rev. 4.15.06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring Diagram – Flat Top Bottle Coolers  
EVAP.  
FAN  
WHITE  
TEMPERATURE  
CONTROL  
EVAP.  
FAN  
2ND FAN ON  
4THRU 8MODELS  
WHITE  
BLACK  
BLACK  
RED  
GREEN  
PLUG-IN-CORD  
TO CONDENSING UNIT  
INSIDE OF  
CONDENSING  
UNIT HOUSING  
INSIDE OF  
CABINET  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
Rev. 4.15.06  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacement Parts – Flat Top Bottle Coolers  
7
23  
9
5A  
14  
19  
8
17  
5
4
6
21  
18  
22  
20  
12  
13  
1
10  
11  
2
3
15  
CAUTION  
Service should be done by a qualified  
refrigeration technician.  
Disconnect all power before servicing  
the cabinet.  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
Rev. 4.15.06  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replacement Parts – Flat Top Bottle Coolers  
MODEL NOS.  
BC24  
BC36  
BC48  
BC60  
BC72  
BC96  
Item Description  
Part Numbers  
Complete condensing unit  
C22648  
C22648  
C22647  
513200314  
215315009  
219101538  
MRT20AGK5590  
213516191  
13556529  
N/A  
C22646  
C22646  
C22646  
1
2
Replacement compressor R134a  
Condensing unit fan motor assy.  
Terminal board  
Overload protector  
Relay  
Start capacitor (282-339MFD)  
Start capacitor (378-454MFD)  
Condensate pan  
513307046  
215315009  
219101538  
4TM762NFBZZ-53  
213514067  
N/A  
N/A  
64537  
63608-1  
C15239A  
65060-1  
63461  
513307046  
215315009  
219101538  
513200003  
215315009  
219101538  
MRT22AFZ5590  
213516051  
N/A  
13556539  
64626-1  
63608-4  
(2) C15239A (2) C15239A (2) C15239A  
(2) 60988-1  
(2) 57699  
C17511-2EP C17511-2EP C17511-2EP  
C15046  
61283  
64644-1  
64643-1  
66397-24L  
66397-36L  
63564  
513200003  
215315009  
219101538  
513200003  
215315009  
219101538  
213514067  
N/A  
213516051  
N/A  
13556539  
64626-1  
63608-5  
213516051  
N/A  
13556539  
64626-1  
63608-6  
N/A  
3
4
5
5A  
6
7
8
9
10  
11  
12  
64626-1  
63608-2  
C15239A  
65060-1  
63461  
64626-1  
63608-3  
Breaker strip kit  
Evaporator fan motor  
Evaporator fan motor bracket  
Evaporator fan blade  
Evaporator coil  
Light bulb (when supplied)  
Temperature control  
Back grille  
Front grille  
Door assembly  
Door assembly (multiple doors)  
Door Lock  
(2) C15239A  
(2) 60988-1  
(2) 57699  
C17511-1EP  
C15046  
61283  
64644-1  
64643-1  
(2) 60988-1  
(2) 57699  
(2) 60988-1  
(2) 57699  
64785-1EP C17511-1EP  
C15046  
61283  
C15046  
61283  
64644-1  
64643-1  
66397-36L  
N/A  
C15046  
61283  
64644-1  
64643-1  
C15046  
61283  
64644-1  
64643-1  
N/A  
64167A-1  
66397-24L  
N/A  
(2) 66397-24L  
N/A  
(2) 66397-36L (2) 66397-36L  
N/A  
63564  
66397-24L  
63564  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
63564  
63564  
63564  
Top wiper gasket  
63671-24  
64814-1  
64815-1  
N/A  
65017-24  
65016-24  
64813-1  
C6713-1  
C17332  
63671-36  
64814-1  
64815-1  
65013-36  
65017-36  
65016-36  
(2) 64719-1  
C6713-1  
C17332  
63671-48  
64814-1  
64815-1  
65013-48  
65017-48  
65016-48  
(2) 64719-1  
C6713-1  
63671-60  
64814-1  
64815-1  
65013-60  
65017-60  
65016-60  
(3) 64719-1  
C6713-1  
C17332  
63671-72  
64814-1  
64815-1  
65013-72  
65017-72  
65016-72  
(4) 64719-1  
C6713-1  
C17332  
63671-96  
64814-1  
64815-1  
65013-96  
65017-96  
65016-96  
(6) 64719-1  
(2) C6713-1  
(2) C17332  
Bottom floor rack (wide)  
Bottom floor rack (narrow)  
Top front rail  
Bottom front rail  
Back rail  
Divider rack  
Bottle cap opener  
Bottle cap holder  
C17332  
22A Bottle cap holder screws  
22B Bottle cap holder spacers  
(2) M00504-122 (2) M00504-122 (2) M00504-122 (2) M00504-122 (2) M00504-122 (4) M00504-122  
(2) C122-2  
64692-24A  
(2) C122-2  
64692-36A  
(2) C122-2  
64692-48A  
(2) C122-2  
64692-60A  
(2) C122-2  
64692-72A  
(4) C122-2  
64692-96A  
23  
Back top assembly  
Items Not Shown  
Wire harness  
65043-1  
63553-1  
63554-1  
65043-1  
63553-1  
63554-1  
65044-1  
63553-1  
63554-1  
65044-1  
63553-1  
63554-1  
65044-1  
63553-1  
63554-1  
65044-1  
63553-1  
63554-1  
Evaporator tube (114” U. bend)  
Evaporator tube (418” U. bend)  
Cap tube/suction line heat  
exchanger with dryer  
65072  
65072  
65073  
65075  
65075  
65075  
Mullion assembly  
Light kit (accessory only)  
Refrigerant charge (oz. R134a)  
63536  
6.0  
63536  
8.5  
64823R  
63536  
9.0  
64823R  
63536  
9.0  
64823R  
63536  
9.0  
(2) 64823R  
63536  
9.0  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
Rev. 4.15.06  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069  
Toll Free 800-558-5592 • E-Mail: [email protected] • www.Perlick.com  
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.  
Form No. Z2219  
Rev. 4.15.06  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer SRC 421 16 User Manual
Philips Battery Charger SCB5655NB User Manual
Philips Cookware HR1619 User Manual
Philips Indoor Furnishings 30187 User Manual
Pioneer Stereo System VSX 817 K User Manual
Polaroid DVD Player PDM 0725 User Manual
POSIFLEX Business Machines Computer Monitor TM4000 Series User Manual
Poulan Snow Blower 422073 User Manual
Poulan Trimmer RTE115 User Manual
Premier Mounts Indoor Furnishings INW AM200 User Manual