INSTALLATION AND OPERATION INSTRUCTIONS
SINGLE DOOR BACK BAR COOLER
MODEL NOS.
CS1DPSP
Table of Contents
IMPORTANT INFORMATION
PREPARING THE CABINET FOR USE
A Warranty card is enclosed that must be filled out
and mailed to the Perlick Corporation in order to reg-
ister the warranty. If the card is not returned to
Perlick, the warranty period will begin from the date
the equipment is shipped from the factory.
Specifications.........................................................2
List of Included Parts.............................................3
Tools Required.......................................................3
Plumbing................................................................3
Electrical ................................................................3
Uncrating ...............................................................3
Installing Casters...................................................3
Placing the Cabinet ...............................................3
Leveling the Cabinet..............................................3
Installing Base Plates ............................................3
TEMPERATURE
Refrigeration and Temperature Control.................4
Adjusting the Temperature.....................................4
CLEANING
Cleaning the Cabinet.............................................4
Cleaning the Condenser........................................4
Condenser .............................................................4
GENERAL INFORMATION
This manual has been prepared to assist you in the
installation of your Single Keg Dispenser and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer can
provide you with a list of qualified service agents. For
your own protection, never return merchandise for
credit without our approval.
We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction.
REPLACEMENT PARTS.......................................5
Wiring Diagram......................................................6
WARNING: When lifting, the full weight of the
cabinet must be supported. Lift from the cabinet
base and not from the top. Improper lifting can
result in severe damage to the cabinet.
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Form No. Z2091A
Rev. 08.03.04
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the Cabinet for Use – Single Door Back Bar Cooler
Parts List
Installing Casters (Optional)
■
(2) Shelves.
Mini-Flourescent Light.
Shelf Clips.
Attach four casters to the cabinet bottom; rigid cast-
ers at the rear and swivel casters on the front. Use
the supplied 1/4”- 20 x 3/4” hex head self-tapping
machine screws.
■
■
Tools Required
■
#2 Phillips Screwdriver.
■
10” Crescent Wrench.
Placing the Cabinet
9/16” Allen Wrench.
■
3/8” Nut driver.
power Drill or Driver (for Leg Installation).
Push the cabinet into place using rollers when
necessary. Important: Proper air flow around the
condensing unit is necessary for efficient operation.
Never obstruct the air flow in and out of the
condensing unit. A minimum of 2” clearance is
required from back.
■
■
Plumbing
Features a floor drain with a 3⁄4” female pipe thread
connection for disposal of condensate. Remove
bottom or side drain plug with Allen wrench and
attach 3⁄4” male pipe to external drain.
Leveling the Cabinet
When the cabinet is in place, check installation with
carpenter’s level. When perfectly level, accumulated
water will drain out. A slight pitch to the drain side
will not harm the cabinet. Water may accumulate if
cabinet is pitched to the opposite side.
Electrical
The cabinet must be connected to a separately
fused power source (see electrical specification
plate) and grounded in accordance with National
and Local Electrical Codes. Caution: Do not
attempt to operate the equipment on any other
power source than that listed on the Electrical
Specification plate.
Installing Base Plate (Optional)
Attach brackets to cabinet bottom in holes provided.
Use #10 self-drilling hex sheetmetal screws. (See
separate instructions, provided with kit). When
returning cabinet to upright position, be careful not
to bend brackets.
Uncrating and Inspection
Remove all crating material before operating.
Carefully inspect cabinet for hidden damage. If
damage is discovered, file your claim immediately
with the transportation company. Perlick is
not responsible for damage in transit.
WARNING!
To avoid compressor damage,after returning
cabinet to an upright position, let unit stand for
24 hours before plugging it in and running the unit.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2091A
Rev. 08.03.04
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General Information – Single Door Back Bar Cooler
Refrigeration and Temperature Control
Cleaning the Cabinet
Use a mild detergent and water to clean the inside
and outside of the cabinet. Dry thoroughly. Never
use a scouring pad or abrasive cleanser.
NOTE: An industrial strength, commercial cleaner
can be used to clean the outside of painted
cabinets.
The Back Bar cabinet is equipped with a heavy-
duty refrigeration system designed to automatically
maintain a storage temperature of 36-41 degrees F.
The control is factory set at 38 degrees F.
Cleaning the Condenser
Use a long handled, stiff brush to clean the dirt from
the front surface of the condenser. Keeping the
condenser free from dust and dirt will ensure effi-
cient operation.
CAUTION: Do not bend the fins while brushing the
front of the condenser.
Condenser
The condenser (located behind the back cover)
should be inspected every 30 days and cleaned, if
necessary. Failure to keep the condenser clean will
cause a loss in condenser unit efficiency.
Adjusting the temperature
The temperature control is inside the cabinet on
the right-hand side of the evaporator fan panel
assembly. You will need a screwdriver to turn the
adjusting screw. Make small adjustments until the
desired temperature is achieved.
■
Colder Temperatures:
Turn the adjusting screw clockwise (to the right).
Warmer Temperatures:
■
Turn the adjusting screw counterclockwise
(to the left).
In normal operation the condensing unit will run
approximately 16 hours per day. The condenser fan
motor turns off and on with the condensing unit.
The evaporator fan motor runs continuously. The
fan motors are lifetime lubricated and will require
no oiling.
NOTE:
Cabinet Temperatures lower than 34° will not allow
for proper defrosting of the evaporator coil. If
defrosting is necessary, turn the control knob to the
OFF position until coil is defrosted.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2091A
Rev. 08.03.04
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacement Parts – Single Door Back Bar Cooler
MODEL NOS.
CS1DP
Item Description
Part #’s
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Compressor for R134a
C22650
C15240A
61289-1
C6914
62209-1
62433-1
62131-1
C18634A
62132-1
C25400A1
C14649
C15239A
62212B
62439
57360
64357SRBL
64357SLBL
63407R
63407L
Condenser fan motor
Condenser fan motor bracket
Condenser fan blade
Condenser fan pan
Rear panel
Back panel partition
Condenser assembly
Condenser panel
Evaporator fan guard
Evaporator fan blade - 51⁄2”
Evaporator fan motor
Evaporator assembly - complete
Top assembly
Temperature control parts kit
Right hinged door assembly
Left hinged door assembly
Door hinge kit, right
Door hinge kit, left
17
18
19
20
Magnetic door gasket
Door sill
Door handle
62085-1
60944-1
C31409-1
Parts Not Shown on Drawing
Light, mini-flourecent
Wiring harness
57822A
61346-1
57851
Door lock with keys
Drain line hose kit
57854
14
12
13
11
9
10
15
6
7
16
8
5
4
3
2
17
1
20
19
18
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2091A
Rev. 08.03.04
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Wiring Diagram – Single Door Back Bar Cooler
EVAPORATOR FAN
BLACK
OUTLET
WHITE
THERMOSTAT
BLACK
CONDENSING UNIT
BLACK
WHITE
GREEN
POWER CONNECTION
JUNCTION BLOCK
8300 West Good Hope Road • Milwaukee, WI 53223 • Phone 414-353-7060 • Fax 414-353-7069
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice. Form No. Z2091A
Rev. 08.03.04
6
Download from Www.Somanuals.com. All Manuals Search And Download.
|