Installation/Operation
KBD100
Universal Keyboard
C529M-D (9/03)
F
2
1
MON
F
2
SEQ
UENCE
A
C
K
F
3
PREV
1
NEXT
3
HOLD
4
MA
CR
O
5
PGM
7
6
8
CAM
9
0
CLEAR
K
B
D
200
M
A
D
E
IN
U
S
A
.
In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel +1(559) 292-1981 • FAX +1(559) 348-1120
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local
codes.
2. This unit is designed for indoor use only and must not be installed where exposed to rain and mois-
ture.
3. Use only replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement be-
tween line and exposed parts to verify the exposed parts have not been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
DESCRIPTION
The KBD100 Universal Keyboard is used to program and operate a CM6700 Matrix Switcher/Controller Unit
(SCU).
The KBD100 provides economical system control and programming capability to locations that do not re-
quire the complete camera control abilities of the KBD200 and KBD300 Series keyboards. Table A lists
the operational functions of the KBD100 keyboard.
Table A. KBD100 Operational Functions
Function
Availability
Yes
Yes
No
Select cameras
Select monitors
Control lenses
Set and call presets/patterns
Control receiver auxiliaries
Control switcher auxiliaries
Control multiplexer
No
No
Yes
No
Control CM6700 Matrix Switcher
Program CM6700 Matrix Switcher
Sequencing
Yes
Yes
Yes
No
Operate frame, auto, and random scans
LOCAL
PORT
CM6700
KBD100
REMOTE
PORT
FROM
KBD100
CAMERAS
REMOTE
KBD100
KBD100
KEYBOARDS
TO
MONITORS
Figure 1. KBD100 Application
[
]
Pelco Manual C529M-D (9/03)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
There are two keyboard ports on the CM6700 Switcher/Control Unit (SCU).
The LOCAL KEYBOARD port is for connecting a single keyboard within a distance of 25 feet (7.6 meters).
The REMOTE KEYBOARD(S) port is for connecting additional remote keyboards.
Connecting a Keyboard to the Local Keyboard Port
1
Use the data cable that is supplied with the keyboard. Plug one end of the cable into the RJ-45 con-
nector on the rear of the keyboard and the other end into the LOCAL KEYBOARD port on the SCU
(refer to Figure 2). Set the keyboard address according to Table B on page 6.
Go to step 2 to install remote keyboards, or go to step 10.
Connecting Keyboards to the Remote Keyboard(s) Port
NOTE: A KBDKIT or KBDKIT-X is required for this application. The KBDKIT consists of two RJ-45 wall
blocks and 120 VAC to 12 VAC transformers. The KBDKIT-X is for 230 VAC. Use one wall block for each
keyboard.
Refer to Figures 2 and 3 for the following steps.
2
3
Select a suitable location for each keyboard and wall block. Wall blocks must be within 6 feet (1.8 m)
of a suitable electrical outlet. Do not mount the wall block yet.
Run wall block interconnect cable (user-supplied) from the SCU to the closest keyboard location, then
to the next nearest location, and the next, etc.
Communication to the keyboards is RS-485. Maximum cable distance for RS-485 communication over
24-gauge wire is 4,000 feet (1,219 m). Pelco recommends using shielded twisted pairs cable that meets
or exceeds the basic requirements for EIA RS-485 applications.
4
5
6
Remove the wall block cover and make cable connections at each wall block according to Figure 3.
At each wall block, wire the transformer to pins 3 and 4. Polarity is unimportant.
Replace the cover on the wall block. Secure the wall block to a suitable surface. A double-sided sticky
pad is provided to mount the wall block.
7
8
9
Set the address switches for each keyboard according to the instructions on page 6.
Plug in all keyboard data cables according to Figure 2.
Plug the KBDKIT or KBDKIT-X transformers into a suitable outlet.
10 To initialize the keyboard, wait five seconds after power-up, enter the number for the monitor you are
viewing (1-4), and press MON. The LED display shows the number selected.
NOTE: You must re-initialize whenever power is cycled.
11 Go to the Programming and Operation Section and program and test for proper operation.
[
]
4
Pelco Manual C529M-D (9/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
KBD
LOCAL
KEYBOARD
LOCAL
KEYBOARD
1
25-FOOT KEYBOARD DATA CABLE
NOTE: A SEPARATE PATH MUST BE PROVIDED
FOR VIDEO TO THE MONITOR.
CM6700
USER-SUPPLIED CABLE
ADDITIONAL
KEYBOARDS
3
REPLACE
COVER
REPLACE
COVER
6
6
KBD
KBD
7
2
2
7
KBDKIT
8
8
SET SWITCHES
(PAGE 6)
25-FOOT KEYBOARD
DATA CABLE
25-FOOT KEYBOARD
DATA CABLE
REMOTE KEYBOARDS
Figure 2. Keyboard Cabling Diagram
LOCAL
RJ-45 WALL BLOCK TERMINALS
4
3
5
6
7
8
2
1
T+ T-
R- R+
4
4
TERMINAL
TERMINAL
USER-SUPPLIED CABLE
1
2
3
4
5
6
7
8
1
2
3
4
TX+
TX+
TX-
AC
AC
TX-
AC
5
5
AC
GND
GND
5
6
7
8
RX-
RX-
RX+
RX+
12 VAC
12 VAC
9
9
Figure 3. Wiring Diagram for Remote Keyboards
[
]
Pelco Manual C529M-D (9/03)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
SWITCH SETTINGS
To set the switches on the keyboard (refer to Figure 4):
1
2
Remove the two screws and the DIP switch cover plate from the rear of the keyboard.
Set the switches:
Address (Switches 1-4)
Position the switches according to Table B. Each keyboard in the sys-
tem must have a different address. To make programming easier, ad-
dress keyboards in ascending order.
NOTE: You may use a total of 8 different addresses between 1 and
16 with the CM6700 SCU.
Table B. Keyboard Addresses
Keyboard
Address
Switch Settings
1
2
3
4
1
2
0
1
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
3
2
OFF
ON
4
3
ON
5
4
OFF
ON
OFF
OFF
ON
6
5
ON
7
6
OFF
ON
ON
8
7
ON
ON
9
8
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
10
11
12
13
14
15
16
9
ON
10
11
12
13
14
15
OFF
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
3
Replace the cover plate.
[
]
6
Pelco Manual C529M-D (9/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
KEYBOARD
DATA
REMOVE DIP
1
SWITCH COVER PLATE
2
ON
1
2
3
4
KEYBOARD
DIP SWITCH
REPLACE
COVER
3
Figure 4. Keyboard Rear Panel
[
]
Pelco Manual C529M-D (9/03)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
PROGRAMMING AND OPERATION
Programming and operation of each function is explained in Tables C and D. Refer to Figure 5 for the lo-
cation of keys.
Table C. Keyboard Definitions for KBD100
Function
Procedure
Select Camera
Enter camera number (1-16) 8 and press CAM 7 to select.
NOTE: The CM6700 can be programmed to restrict some monitors from
viewing certain cameras. To display a camera’s view on your monitor, be sure
that your keyboard shows the number of the monitor you are viewing and be
sure that the CM6700 has not been programmed to restrict viewing of that
camera.
Select Monitor
Sequence
LED display 1 shows monitor number in run mode.
Enter monitor number (1-4) 8 and press MON 10 to select.
Sequence steps through all 16 cameras. Camera number, camera title, se-
quence status, and time/date are shown on the monitor.
Press PREV 2 to step back one camera. Hold for two seconds for a back-
A
ward sequence. Monitor shows B. Press during sequence to speed up. Press
during a forward sequence to reverse.
Press NEXT 2B to step forward one camera. Hold for two seconds for a for-
ward sequence. Monitor shows F. Press during sequence to speed up. Press
during a backward sequence to go forward.
Press HOLD 2C to hold a sequence. Monitor shows H. Press PREV or NEXT
to resume.
Manually select a camera or press CAM 7 to turn off a sequence. Monitor shows O.
Macro Sequence
Auxiliaries/Relays
Enter 1 or 2 8 and press MACRO 5 to start a group camera sequence. Moni-
tor shows M. Refer to the CM6700 manual for macro/sequence programming.
F1-F3 3 control only the auxiliaries built into the CM6700 SCU.
These outputs can be programmed for momentary, keyed, latched, or alarm
operation. See the CM6700 SCU manual for programming instructions.
F1: Activate/deactivate switcher auxiliary 1 relay.
F2: Activate/deactivate switcher auxiliary 2 TTL output.
F3: Activate/deactivate switcher auxiliary 3 TTL output.
Acknowledge Alarm
Program (CM6700)
Press ACK 9 to acknowledge an alarm. Refer to the CM6700 manual for fur-
ther information on alarms.
To program the CM6700 switcher, press PGM 4 . Follow the programming
procedure in the CM6700 manual. LED Display 1 shows P in program mode.
Press ACK 9 to exit.
LED
LED 1 shows monitor number or P (in program mode).
Clear
Press CLEAR 6 to cancel a number that has been entered.
[
]
8
Pelco Manual C529M-D (9/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
2B
2C
2A
3
1
4
F1
F2
F3
SEQUENCE
MON
ACK
PREV
1
NEXT
2
HOLD
MACRO
PGM
3
10
9
4
7
5
8
0
6
9
CAM
CLEAR
5
KBD100
MADE IN USA.
8
6
7
Figure 5. Keyboard Functions
Table D. KBD100 Button Functions
Reference
Description
Number
1
LED display
2A-2C
Sequence keys: Previous, Next, Hold
3
4
Function keys F1, F2, F3 control auxiliaries
Program key
5
Macro sequence key
Clear key
6
7
Camera selection key
Keypad (numbers 1 through 0)
Acknowledge key
8
9
10
Monitor selection key
[
]
Pelco Manual C529M-D (9/03)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
GENERAL
Keyboard Keypad:
Digital Display:
Electromechanical
Red LED, 7-segment, 2 cells
Ambient Operating
Temperature:
20° to 120°F (-7° to 49°C)
Humidity:
10-90% non-condensing
Dimensions:
6.00 (W) x 7.125 (D) x 2.25 (H) inches (15.24 x 18.10 x 5.72 cm)
1.9 lb (0.86 kg)
Weight:
ELECTRICAL
Input Voltage:
Power Consumption:
Connector Type:
12 VAC or ±12 VDC
5 watts
RJ-45, 8-pin modular (female)
Keyboard Communication
Interface:
Protocol:
RS-485
Pelco ASCII
9600
Baud:
Communication Parameters: 8 data bits, odd parity, 1 stop bit
(Design and product specifications subject to change without notice.)
This equipment contains electrical or electronic components that must be recycled properly to comply with
Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic
equipment (WEEE). Contact your local dealer for procedures for recycling equipment.
[
]
10
Pelco Manual C529M-D (9/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
INDEX
A
O
Acknowledge Alarm 8
Auxiliaries 8
Operation 8
Operation functions 8
C
P
Clear 8
Program CM6700 8
Programming 8
D
R
Description 3
DIP switch 6
Regulatory notices 2
Relays 8
Returns 12
I
RS-485 cable distance 4
Installation 4
S
K
Safeguards 3
KBDKIT 4
KBDKIT-X 4
Keyboard Addresses 6
Select Camera 8
Select Monitor 8
Sequence 8
Specifications 10
Switch Settings 6
L
LED 8
W
M
Wall block 4
Warranty 12
Macro Sequence 8
[
]
Pelco Manual C529M-D (9/03)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
•
•
•
Five years on FT/FR8000 Series fiber optic products.
Three years on Genex® Series products (multiplexers, server, and keyboard).
Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models, which have a five-year warranty.
•
•
•
•
•
Two years on standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura™ Series distributed network-based video
products.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this
warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
3500 Pelco Way
Clovis, CA 93612-5699 USA
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
© Copyright 2000, Pelco. All rights reserved.
REVISION HISTORY
Manual #
C529M
C529M-A
C529M-B
Date
7/97
12/97
5/98
Comments
Original version.
Revision a. Revised installation instructions.
Revised installation instructions as a result of hardware changes to the rear panel of the
CM6700 SCU. Removed references to KBD100-X because model has been replaced with
KBDKIT-X. Changed manual pagination.
6/98
10/98
8/00
9/03
Added Section 1.2, Regulatory Notices and Section 2.2, Certifications.
Revised Table A.
Revised format.
C529M-C
C529M-D
Added uL certification seal. Changed power consumption specification.
[
]
12
Pelco Manual C529M-D (9/03)
Download from Www.Somanuals.com. All Manuals Search And Download.
|