I N S T A L L A T I O N
RK5000PS-3U/RK5000-3U
Rack Mount Chassis
®
For Fiber Optic Modules
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Front View (RK5000PS-3U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Back View (RK5000-3U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Mounting a Chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Installing a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Installing a Blank Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Replacing an Internal Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
C1972M (11/04)
3
Download from Www.Somanuals.com. All Manuals Search And Download.
List of Illustrations
9
RK5000-3U Back View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Power Bus Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Internal Power Supply Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4
C1972M (10/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
Important Safety Instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A
grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from
the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use
caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
15. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the
apparatus.
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
17. Installation should be done only by qualified personnel and conform to all local codes.
18. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not
be installed where exposed to rain and moisture.
19. Use only installation methods and materials capable of supporting four times the maximum specified load.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform
any servicing other that contained in the operating instructions unless you are qualified to do so.
21. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:.
WARNING: This symbol indicates that dangerous voltage constituting a risk of electric
shock is present within this unit
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
C1972M (11/04)
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Notices
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.” This
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this
equipment under Federal Communications Commission’s rules.
6
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
Description
The RK5000PS-3U rack mount chassis supports fiber optic modules. The chassis has 12 slots and an internal double-width power supply. You can
insert up to 12 single-width modules or a combination of single-width and double-width modules into the slots. For redundancy, you can use the
optional external power supply (EPS5000-120). It provides redundant power for up to two fully populated RK5000PS-3U chassis. You can mount
the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch rack.
The RK5000-3U chassis has 14 slots and requires an external power supply. You can insert up to 14 single-width modules or a combination of
single-width and double-width modules into the slots. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch
rack. You can use the optional EPS5000-120 external power supply, which consists of dual 120 watt, hot swappable power supplies, to power up
to two fully populated RK5000-3U chassis. The EPS5000-120 is 1 RU high and rack mountable.
You can fill the empty module slots on either chassis with single-width blank modules (RK5001B-3U) and double-width blank modules
(RK50002B-3U).
MODELS
RK5000PS-3U
RK5000-3U
Rack mountable chassis with power supply, 3 RU
Rack mountable chassis, 3 RU; external power supply required
C1972M (11/04)
7
Download from Www.Somanuals.com. All Manuals Search And Download.
FRONT VIEW (RK5000PS-3U)
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
ᕦ
Rack Ears (2)
Power Supply
Module Slots (12)
Alarm from Module LED
Power Fail LED
Pelco Badge
ᕡ
ᕢ
ᕦ
ᕤ
ᕥ
ᕣ
Figure 1. RK5000PS-3U Front View
BACK VIEW (RK5000PS-3U)
ᕡ
ᕢ
ᕣ
ᕤ
ᕥ
Thumbscrews for Fastening Modules (12)
External Connector for Redundant Power Supply
Relay Output Connector with Screw Terminal
Power Button
Power Cord Connector
ᕢ
ᕣᕤᕥ
ᕡ
Figure 2. RK5000PS-3U Back View
8
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
FRONT VIEW (RK5000-3U)
ᕡ
ᕢ
Rack Ears (2)
Module Slots (14)
ᕡ
ᕢ
Figure 3. RK5000-3U Front View
BACK VIEW (RK5000-3U)
ᕡ
ᕢ
External Connector for Redundant Power Supply
Thumbscrews for Fastening Modules (14)
ᕡ
ᕢ
Figure 4. RK5000-3U Back View
C1972M (11/04)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
PACKAGE CONTENTS
RK5000PS-3U
1 Rack mount chassis
4 Screws and washers for rack mounting
RK5000-3U
1 Rack mount chassis
4 Screws and washers for rack mounting
MOUNTING A CHASSIS
The procedure for mounting an RK5000PS-3U and an RK5000-3U into a rack is exactly the same. To mount a chassis, follow these steps and refer
1. Insert the chassis into the rack.
2. Secure the chassis with the supplied screws and washers.
Figure 5. Mounting an RK5000PS-3U/RK5000-3U into a Rack
10
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLING A MODULE
You can install single-width or double-width modules into the empty slots on the RK5000PS-3U chassis and RK5000-3U chassis. To install a
1. Insert the module into an empty slot of the chassis.
2. Secure the module by tightening the thumbscrew on the back of the chassis.
Figure 6. Module Installation
INSTALLING A BLANK MODULE
You can use single-width or double-width blank modules to fill the empty module slots on the chassis. To attach a blank module, follow these
1. Insert the blank module into the empty slot on the chassis.
2. Secure the blank module by tightening the thumbscrew on the back of the chassis.
Figure 7. Blank Module Installation
C1972M (11/04)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Service
REMOVING THE POWER BUS
You must remove the power bus from the RK5000PS-3U if you want to use the power supplies that are provided with the Fiber modules.
WARNING: Using the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS-3U can cause
damage to the unit.
1. Turn off the power supply.
2. Remove the power supply.
3. Unscrew the five Phillips flat head screws.
Figure 8. Power Bus Removal
12
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
REPLACING AN INTERNAL POWER SUPPLY
You can easily replace the internal power supply in the RK5000PS-3U in case of failure. The front of the power supply has two LEDs. The top LED
turns red when there is an alarm condition from one of the modules. The bottom LED turns red when the power supply fails. To replace an
internal power supply, follow these steps and refer to Figure 9.
1. Unplug the power cord.
2. Unscrew the two thumbscrews on the back of the chassis that hold the power supply.
3. Remove the power supply.
4. Insert the new power supply.
5. Secure the power supply by tightening the two thumbscrews on the back of the chassis.
6. Plug in the power cord.
7. Turn on the power supply.
Figure 9. Internal Power Supply Replacement
C1972M (11/04)
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
RK5000PS-3U
ELECTRICAL
Input Voltage
100-240 VAC
Output Voltage
Power Consumption
Fuse
12 VDC
120 watts maximum
1.6 A
Redundant Capability
Yes with optional EPS5000-120 power supply
MECHANICAL
Number of Slots
Module Orientation
Rack Units
12 for modules and 2 for power supply
Vertical
3
Construction
Finish
Aluminum
Black
GENERAL
Operating Temperature
Operating Humidity
Storage Humidity
Dimensions
32° to 122°F (0° to 50°C)
80% maximum relative humidity, noncondensing
95% maximum relative humidity, noncondensing
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Fits 19-inch, EIA-standard rack
Mounting
Unit Weight
8.01 lb (3.63 kg), with power supply
25.53 lb (11.58 kg), fully populated
RK5000-3U
MECHANICAL
Number of Slots
Module Orientation
Rack Units
14 for modules
Vertical
3
Construction
Finish
Aluminum
Black
GENERAL
Dimensions
Mounting
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)
Fits 19-inch, EIA-standard rack
Unit Weight
5.19 lb (2.35 kg), chassis only
25.63 lb (11.63 kg), fully populated
14
C1972M (11/04)
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following
information:
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment.
1. Model and serial number
Exceptions to this warranty are as noted below:
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
•
Five years on FT/FR8000 Series fiber optic products and the following fixed camera models:
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and CC3651H-2X.
If there is a dispute regarding the warranty of a product which does not fall under the
warranty conditions stated above, please include a written explanation with the product
when returned.
•
Three years on all other fixed camera models (including Camclosure® Integrated Camera
Systems) and Genex® Series (multiplexers, server, and keyboard).
Method of return shipment shall be the same or equal to the method by which the item was
received by Pelco.
•
•
Two years on all standard motorized or fixed focal length lenses.
Two years on Legacy®, CM6700/CM6800/CM8500/CM9500/CM9700 Series Matrix, DF5
and DF8 Series Fixed Dome products.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned
for credit, and RA number if returned for repair).
•
Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous
motion applications.
•
•
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing
charge.
Eighteen months on DX Series digital video recorders and NVR300 Series network video
recorders, and all Endura™ Series distributed network based video products.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA
number and freight should be prepaid. Ship to the appropriate address below.
•
•
One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
Six months on all pan and tilts, scanners or preset lenses used in continuous motion
applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are
instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from
the specific use or application made of the Products. Pelco’s liability for any claim, whether
based on breach of contract, negligence, infringement of any rights of any party or product
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for
such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused,
whether by the negligence of Pelco or otherwise.
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
Phone: 650-737-1700
Fax: 650-737-0933
REVISION HISTORY
Manual #
Date
Comments
C1972M
11/04
Original version.
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.
© Copyright 2004, Pelco. All rights reserved.
Download from Www.Somanuals.com. All Manuals Search And Download.
®
Worldwide Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
ISO9001
United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.
|