Pelco Home Security System RK5000 3U User Manual

I N S T A L L A T I O N  
RK5000PS-3U/RK5000-3U  
Rack Mount Chassis  
®
For Fiber Optic Modules  
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
C1972M (11/04)  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
List of Illustrations  
9
4
C1972M (10/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Important Safety Instructions  
1. Read these instructions.  
2. Keep these instructions.  
3. Heed all warnings.  
4. Follow all instructions.  
5. Do not use this apparatus near water.  
6. Clean only with dry cloth.  
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.  
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.  
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A  
grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided  
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.  
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from  
the apparatus.  
11. Only use attachments/accessories specified by the manufacturer.  
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use  
caution when moving the cart/apparatus combination to avoid injury from tip-over.  
13. Unplug this apparatus during lightning storms or when unused for long periods of time.  
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-  
supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or  
moisture, does not operate normally, or has been dropped.  
15. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the  
apparatus.  
16. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.  
17. Installation should be done only by qualified personnel and conform to all local codes.  
18. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not  
be installed where exposed to rain and moisture.  
19. Use only installation methods and materials capable of supporting four times the maximum specified load.  
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform  
any servicing other that contained in the operating instructions unless you are qualified to do so.  
21. Only use replacement parts recommended by Pelco.  
The product and/or manual may bear the following marks:.  
WARNING: This symbol indicates that dangerous voltage constituting a risk of electric  
shock is present within this unit  
CAUTION:  
RISK OF ELECTRIC SHOCK.  
DO NOT OPEN.  
This symbol indicates that there are important operating and maintenance instructions in  
the literature accompanying this unit.  
C1972M (11/04)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Regulatory Notices  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful  
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  
RADIO AND TELEVISION INTERFERENCE  
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits  
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can  
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio  
communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause  
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try  
to correct the interference by one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and the receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio/TV technician for help.  
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve Radio-TV Interference Problems.” This  
booklet is available from the U.S. Government Printing Office, Washington D.C. 20402.  
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this  
equipment under Federal Communications Commission’s rules.  
6
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Description  
The RK5000PS-3U rack mount chassis supports fiber optic modules. The chassis has 12 slots and an internal double-width power supply. You can  
insert up to 12 single-width modules or a combination of single-width and double-width modules into the slots. For redundancy, you can use the  
optional external power supply (EPS5000-120). It provides redundant power for up to two fully populated RK5000PS-3U chassis. You can mount  
the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch rack.  
The RK5000-3U chassis has 14 slots and requires an external power supply. You can insert up to 14 single-width modules or a combination of  
single-width and double-width modules into the slots. You can mount the chassis, which is 3 rack units (RU) high, into an EIA-standard, 19-inch  
rack. You can use the optional EPS5000-120 external power supply, which consists of dual 120 watt, hot swappable power supplies, to power up  
to two fully populated RK5000-3U chassis. The EPS5000-120 is 1 RU high and rack mountable.  
You can fill the empty module slots on either chassis with single-width blank modules (RK5001B-3U) and double-width blank modules  
(RK50002B-3U).  
MODELS  
RK5000PS-3U  
RK5000-3U  
Rack mountable chassis with power supply, 3 RU  
Rack mountable chassis, 3 RU; external power supply required  
C1972M (11/04)  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
FRONT VIEW (RK5000PS-3U)  
Rack Ears (2)  
Power Supply  
Module Slots (12)  
Alarm from Module LED  
Power Fail LED  
Pelco Badge  
Figure 1. RK5000PS-3U Front View  
BACK VIEW (RK5000PS-3U)  
Thumbscrews for Fastening Modules (12)  
External Connector for Redundant Power Supply  
Relay Output Connector with Screw Terminal  
Power Button  
Power Cord Connector  
ᕣᕤᕥ  
Figure 2. RK5000PS-3U Back View  
8
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
FRONT VIEW (RK5000-3U)  
Rack Ears (2)  
Module Slots (14)  
Figure 3. RK5000-3U Front View  
BACK VIEW (RK5000-3U)  
External Connector for Redundant Power Supply  
Thumbscrews for Fastening Modules (14)  
Figure 4. RK5000-3U Back View  
C1972M (11/04)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Installation  
PACKAGE CONTENTS  
RK5000PS-3U  
1 Rack mount chassis  
4 Screws and washers for rack mounting  
RK5000-3U  
1 Rack mount chassis  
4 Screws and washers for rack mounting  
MOUNTING A CHASSIS  
The procedure for mounting an RK5000PS-3U and an RK5000-3U into a rack is exactly the same. To mount a chassis, follow these steps and refer  
1. Insert the chassis into the rack.  
2. Secure the chassis with the supplied screws and washers.  
Figure 5. Mounting an RK5000PS-3U/RK5000-3U into a Rack  
10  
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
INSTALLING A MODULE  
You can install single-width or double-width modules into the empty slots on the RK5000PS-3U chassis and RK5000-3U chassis. To install a  
1. Insert the module into an empty slot of the chassis.  
2. Secure the module by tightening the thumbscrew on the back of the chassis.  
Figure 6. Module Installation  
INSTALLING A BLANK MODULE  
You can use single-width or double-width blank modules to fill the empty module slots on the chassis. To attach a blank module, follow these  
1. Insert the blank module into the empty slot on the chassis.  
2. Secure the blank module by tightening the thumbscrew on the back of the chassis.  
Figure 7. Blank Module Installation  
C1972M (11/04)  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
       
Service  
REMOVING THE POWER BUS  
You must remove the power bus from the RK5000PS-3U if you want to use the power supplies that are provided with the Fiber modules.  
WARNING: Using the power supplies that are provided with the Fiber modules with the power bus on the RK5000PS-3U can cause  
damage to the unit.  
1. Turn off the power supply.  
2. Remove the power supply.  
3. Unscrew the five Phillips flat head screws.  
Figure 8. Power Bus Removal  
12  
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
     
REPLACING AN INTERNAL POWER SUPPLY  
You can easily replace the internal power supply in the RK5000PS-3U in case of failure. The front of the power supply has two LEDs. The top LED  
turns red when there is an alarm condition from one of the modules. The bottom LED turns red when the power supply fails. To replace an  
1. Unplug the power cord.  
2. Unscrew the two thumbscrews on the back of the chassis that hold the power supply.  
3. Remove the power supply.  
4. Insert the new power supply.  
5. Secure the power supply by tightening the two thumbscrews on the back of the chassis.  
6. Plug in the power cord.  
7. Turn on the power supply.  
Figure 9. Internal Power Supply Replacement  
C1972M (11/04)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
Specifications  
RK5000PS-3U  
ELECTRICAL  
Input Voltage  
100-240 VAC  
Output Voltage  
Power Consumption  
Fuse  
12 VDC  
120 watts maximum  
1.6 A  
Redundant Capability  
Yes with optional EPS5000-120 power supply  
MECHANICAL  
Number of Slots  
Module Orientation  
Rack Units  
12 for modules and 2 for power supply  
Vertical  
3
Construction  
Finish  
Aluminum  
Black  
GENERAL  
Operating Temperature  
Operating Humidity  
Storage Humidity  
Dimensions  
32° to 122°F (0° to 50°C)  
80% maximum relative humidity, noncondensing  
95% maximum relative humidity, noncondensing  
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)  
Fits 19-inch, EIA-standard rack  
Mounting  
Unit Weight  
8.01 lb (3.63 kg), with power supply  
25.53 lb (11.58 kg), fully populated  
RK5000-3U  
MECHANICAL  
Number of Slots  
Module Orientation  
Rack Units  
14 for modules  
Vertical  
3
Construction  
Finish  
Aluminum  
Black  
GENERAL  
Dimensions  
Mounting  
5.22” H x 18.99” W x 8.85” D (13.26 x 48.23 x 22.48 cm)  
Fits 19-inch, EIA-standard rack  
Unit Weight  
5.19 lb (2.35 kg), chassis only  
25.63 lb (11.63 kg), fully populated  
14  
C1972M (11/04)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PRODUCT WARRANTY AND RETURN INFORMATION  
WARRANTY  
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or  
(559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following  
information:  
Pelco will repair or replace, without charge, any merchandise proved defective in material or  
workmanship for a period of one year after the date of shipment.  
1. Model and serial number  
Exceptions to this warranty are as noted below:  
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number  
3. Details of the defect or problem  
Five years on FT/FR8000 Series fiber optic products and the following fixed camera models:  
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and CC3651H-2X.  
If there is a dispute regarding the warranty of a product which does not fall under the  
warranty conditions stated above, please include a written explanation with the product  
when returned.  
Three years on all other fixed camera models (including Camclosure® Integrated Camera  
Systems) and Genex® Series (multiplexers, server, and keyboard).  
Method of return shipment shall be the same or equal to the method by which the item was  
received by Pelco.  
Two years on all standard motorized or fixed focal length lenses.  
Two years on Legacy®, CM6700/CM6800/CM8500/CM9500/CM9700 Series Matrix, DF5  
and DF8 Series Fixed Dome products.  
RETURNS  
In order to expedite parts returned to the factory for repair or credit, please call the factory at  
(800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned  
for credit, and RA number if returned for repair).  
Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous  
motion applications.  
Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).  
All merchandise returned for credit may be subject to a 20% restocking and refurbishing  
charge.  
Eighteen months on DX Series digital video recorders and NVR300 Series network video  
recorders, and all EnduraSeries distributed network based video products.  
Goods returned for repair or credit should be clearly identified with the assigned CA or RA  
number and freight should be prepaid. Ship to the appropriate address below.  
One year (except video heads) on video cassette recorders (VCRs). Video heads will be  
covered for a period of six months.  
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:  
Service Department  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699  
Six months on all pan and tilts, scanners or preset lenses used in continuous motion  
applications (that is, preset scan, tour and auto scan modes).  
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco  
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,  
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident  
are not covered under this warranty.  
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are  
instructed to return goods to the USA, you may do one of the following:  
If the goods are to be sent by a COURIER SERVICE, send the goods to:  
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from  
the specific use or application made of the Products. Pelco’s liability for any claim, whether  
based on breach of contract, negligence, infringement of any rights of any party or product  
liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for  
such Products. In no event will Pelco be liable for any special, incidental or consequential  
damages (including loss of use, loss of profit and claims of third parties) however caused,  
whether by the negligence of Pelco or otherwise.  
Pelco  
3500 Pelco Way  
Clovis, CA 93612-5699 USA  
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:  
Pelco c/o Expeditors  
473 Eccles Avenue  
South San Francisco, CA 94080 USA  
The above warranty provides the Dealer with specific legal rights. The Dealer may also have  
additional rights, which are subject to variation from state to state.  
Phone: 650-737-1700  
Fax: 650-737-0933  
REVISION HISTORY  
Manual #  
Date  
Comments  
C1972M  
11/04  
Original version.  
Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.  
© Copyright 2004, Pelco. All rights reserved.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
®
Worldwide Headquarters  
3500 Pelco Way  
Clovis, California 93612 USA  
USA & Canada  
Tel: 800/289-9100  
Fax: 800/289-9150  
International  
Tel: 1-559/292-1981  
Fax: 1-559/348-1120  
ISO9001  
United States Canada United Kingdom The Netherlands Singapore Spain Scandinavia France Middle East  
|
|
|
|
|
|
|
|
Download from Www.Somanuals.com. All Manuals Search And Download.  

Peavey Music Mixer 600 Mixer User Manual
Philips Cordless Telephone SBC SC205 User Manual
Philips Digital Photo Frame 7FF2 User Manual
Philips Video Gaming Accessories SGC5103BD User Manual
Polk Audio Speaker AMR50 User Manual
Polk Audio Speaker MM840SVC User Manual
Polycom Server 1725 36031 001 User Manual
Praktica Digital Camera D00387 User Manual
Premier Mounts Indoor Furnishings PP FCMA User Manual
PYLE Audio Car Video System PLVWR81IR User Manual