Model : OS200
User Manual
Mode d’emploi
Manual de Usuario
Bedienungsanleitung
Gebruiksaanwijzing
Bruksanvisning
Manuale
manual-E.p65
1
2004/5/18, PM 12:17
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing a Contact ................................ 7
Speed Dial ............................................... 7
Accessories and Spare Parts ....................... 8
Accessory Descriptions ................................. 8
Acoustics................................................... 8
Troubleshooting........................................... 8
Technical Information ................................. 9
About Oregon Scientific .............................. 9
CONFERENCEPHONE
MODEL: OS200
USER MANUAL
TABLE OF CONTENTS
Introduction .................................................. 1
Safety and Care ........................................... 1
Key Features ................................................ 2
Getting Started ............................................ 4
Package Contents .................................... 4
Connecting for the First Time ................. 4
Selecting Language ................................ 4
Setting Time and Date ........................... 4
Programming the R Key .......................... 4
Making Phone Calls .................................... 5
Incoming Calls ......................................... 5
Outgoing Calls ......................................... 5
3-Way Calling .......................................... 5
Call Settings................................................. 5
Speaker Volume ...................................... 5
Manual Tuning ........................................ 5
Keypad Tone ........................................... 5
Ring Volume ............................................ 6
Call Functions .............................................. 6
Redial ....................................................... 6
Mute ......................................................... 6
Using the Phonebook .................................. 6
Adding Contacts to Phonebook .............. 6
Editing Contact List ................................. 7
manual-E.p65
3
2004/5/18, PM 12:17
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
INTRODUCTION
To clean the unit use a soft dry cloth, always
keep it away from moisture.
This product integrates a highly sensitive
microphone set-up and three built-in surround
sound speakers, allowing users from all around the
room to participate in conference discussions.
Some features of this product include:
•
•
•
•
•
Backlit LCD
Time, date, and language settings
Tape recorder connectivity
Contact list
Acoustic and line echo elimination
SAFTEY AND CARE
Your OS200 conference phone has been designed
to provide you with many years of reliable
service. To ensure that you use the product
safely and correctly, observe the following safety
warnings:
•
Your OS200 conference phone is dependent
on AC power source for operation, and may
not work during power and telephone outages.
•
Do not use your OS200 conference phone in
or near water, as this can cause damage to
the unit and personal injury through electric
shock.
•
•
Do not attempt to open or modify your
telephone.
The product, specifications and contents of this
user manual are subject to change without
further notice.
•
Figures and display examples in this user
manual are for reference only, and may differ
slightly from the actual product.
1
manual-E.p65
4
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
KEYFEATURES
TOP VIEW
1. Loudspeaker
2. Microphone status indicators (blue / red)
3. Microphone
4. Remote control sensor
5. Display
6. Keypad
BOTTOM VIEW
1. Output for tape recorder
2. Power supply
3. Telephone line input
4. Microphone inputs
2
manual-E.p65
5
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
LCD
KEYPAD
5, J,K,L,j,k,l
9,W,X,Y,Z,w,x,y,z
1, space, . (period)
6,M,N,O,Ö,Ø,Ñ,m,n,o,ö,ø,ñ
7,P,Q,R,S,p,q,r,s
0
*
2, A, B, C, Å, Ä, Á,À,a,b,c,å,ä,á, à
3, D,E,F,É,È,d,e,f,é,è
4, G,H,I,g,h,i
8,T,U,V,Ü,Ú,t,u,v,ü,ú
#
3
manual-E.p65
6
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTING THE TIME AND DATE
1. Press
GETTING STARTED
PACKAGE CONTENTS
2
.
Scroll to Time/Date menu by pressing
•
•
•
•
•
Conference Phone
Instruction Manual
Power and network cable
Power adaptor
Press
to confirm.
3. Press
to scroll between the DATE,
MONTH, YEAR, HOUR, and MINUTES fields.
4. Press to select a field to adjust. Use
to adjust values, then to
Intermediate plugs
CONNECTING FOR THE FIRST TIME
confirm.
When using the OS200 for the first time, you must
first connect the unit to a power supply and
analogue phone line using the supplied adaptor
and connection cables. This phone does not work if
connected to a digital line.
5. Select other fields as necessary. Press
go back to the main menu.
to
PROGRAMMING THE R KEY
Depending on what region the phone will be used
in, the R key should be programmed to make sure
R-Pulse times are compatible with most PBXs
(private telephone networks).
Power
adaptor
connects to
mains outlet
Connect to telephone line
NOTE: The default setting is R2
Connectors
underneath
OS200
Value Time (ms)
PBX / country
Ericsson MD110
Scandinavia, Europe
Reserved
R1
R2
R3
R4
R5
65
100
150
270
600
SELECT LANGUAGE
Germany, France
USA
1. Press
2. Scroll to Language menu by pressing
until you reach the icon display below. Press
to confirm.
1. Press
.
2. Scroll to Special Settings menu by press
. Press to confirm.
3. Choose the desired language by pressing
.
3. Scroll to the R-function setting by press
. Press
.
4. Press
to confirm.
4
manual-E.p65
7
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Choose the required R-pulse value with
.
4. Enter the second phone number.
5. When the second call is connected press
and then
NOTE: If your second call was not answered, press
and then to return to the first call.
to connect all parties.
5. Press
to save changes and exit.
MAKING PHONECALLS
CALL SETTINGS
SPEAKER VOLUME
INCOMING CALLS
When an incoming call is
received, a ringing tone will
be heard and the micro-
phone indicator light will
light up.
During a call, you can
press
to change
the volume.
1. Press
2. Press
to answer.
MANUAL TUNING
The OS200 will automatically modify its properties
for better quality sound in the room and over the
telephone line. However, tuning can be initiated
to end the call.
manually by pressing
noise will be heard).
simultaneously (brief
OUTGOING CALLS
To make an outgoing call:
1. Press
2. Dial the desired number.
KEY PAD TONE
.
When dialling a number, touch-tones will still be
heard even though the keypad tone function is
switched off.
3. Press
to connect.
1. Press
.
Indicates the duration of
2. Scroll to Special Settings menu
.
the call.
4. Press
to end the call.
TIP: To preview, first enter the phone number.
3. Press
.
3-WAY CALLING
4. Scroll to Keypad Tone setting
.
This feature allows you to talk with up to two other
parties simultaneously, contact your local telephone
operator for the availability of this service.
5. Press
.
1. Enter the first phone number.
2. Press
.
3. After the first call is connected, press
get a new dial tone.
to
5
manual-E.p65
8
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Select to turn keypad tone on/off:
•
USING THE PHONEBOOK
ADDING CONTACTS TO PHONE BOOK
Add numbers to your phone book to organize your
contacts and enjoy the convenience of speed dial.
•
1. Press
.
7. Press
to save changes.
2. Scroll to the Phone Book menu
.
RING VOLUME
1. Press
.
3. Press
.
2. Scroll to Ring Signal Volume menu
.
4. Scroll to “Add entry”
.
3. Press
4. Press
.
The either:
to adjust the volume or switch the
• Press
and the number last dialled will
ringer off .
appear automatically.
5. Press
to save changes
or
• Enter a telephone number using the keypad.
CALL FUNCTIONS
5. Press
.
REDIAL
You can call the last number dialled by:
1. Press UP to display the last number dialled.
6. Enter a name using the keypad:
Press the number that corresponds with the
desired letter until you find the right one, pause
and then enter the next letter.letter. For more
information about how to enter a name using
the keypad, please refer to the “Keypad”
subsectonsubsection in “Key Features”.
2. Press
3. Press
to dial the number.
to end the call.
MUTE
7. Press
to save changes.
This feature allows you to turn the microphone off
during private discussions.
TIP: • Press
• Press
to change caps.
key to delete a character/
1. Press
to activate.
number.
2. Press
to deactivate.
• Press
to cancel.
ON
LED (red)
NOTE: You can save up to 50 messages in your
OFF
LED (blue)
phonebook.
6
manual-E.p65
9
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
7. Press
to select.
EDITING CONTACT LIST
1. Press
.
2. Scroll to the Phone Book menu
.
Confirmation appears in the display
3. Press
.
•
•
Press
Press
to cancel.
to confirm the deletion.
4. Using the
key select EDIT.
SPEEDDIAL
5. Press
.
You can dial previously stored numbers in your
book by:
6. Scroll to the name you want to edit
.
1. Scroll through witht
contact .
to find the desired
7. Press
.
8. Edit number using the keypad.
2. Press
3. Press
to call contact.
to end call.
9. Press
.
10. Edit name using the keypad.
11. Press
to save changes.
TIP: • Press
key to delete a character/
to cancel.
number.
• Press
REMOVING A CONTACT
1. Press
.
2. Scroll to the Phone Book menu
.
3. Press
.
.
4. Select “Erase”
5. Press
.
6. Scroll to the name you wish to delete
.
7
manual-E.p65
10
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
ACCESSORIES AND SPAREPARTS
ACCESSORIES DESCRIPTIONS
ACOUSTICS
Please contact your local distributor for details
about the availability of accessories and spare
parts.
The OS200 delivers clear audible sound to the
user. For optimum results the unit should be
positioned accordingly as shown here:
TELE PLUGS
Item No.
Description
Denmark
Finland
France
Germany
UK
Netherlands
Norway
•
Layout for room sizes up to 30m2 (323 sq. feet).
Spain
Sweden
Switzerland
TROUBLESHOOTING
PROBLEM
CHECK THIS
Third party called
does not answer
Press
and then 1
SPARE PARTS
Item No.
to return to the first call.
Description
Audio quality is not Manually tune the
clear acoustics (
Called party cannot Check that the micro-
Power supply and analogue
POTS network cable, 7.5m
(25ft)
)
hear you
phone is active (red light /
)
Mains transformer 12V DC
(Europe)
Unit not functioning Bypass any extension
Mains transformer 12V DC
(UK)
correctly
cables and connect your
unit to the phone socket
directly
Mains transformer 12V DC
(US)
Disconnect any extra
microphnoes attached
and try again
When using the
3-way calling
Insert a pause using the
key when entering
numbers in the phone
book.
function and you
cannot get a
second dial tone
8
manual-E.p65
11
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
condensing.
Cannot save a
contact “Memory
Full” is displayed
on LCD
Phone book is full (
delete a contact to make
room ( ).
),
EMC
: EN 50 081-1:1992
EN 55 024-1:1998
EN 60950
Electrical safety
Telecom approval POTS
Keyboard
: EN 60950.
: EUROPEAN TBR21.
: 19 keys.
TECHNICAL INFORMATION
MAIN UNIT
Compatibility
: OS200 can be con-
nected to any PBX
equipped with a
POTS extension, for
example Ericsson:
MD110, Fenix.
Siemens: Hicom.
Nortel: Meridan.
Philips:Sopho.
Alcatel: 4200, 4400.
Ascom: Ascotel.
Mains transformer
(Europe)
: DC transformer240V
AC/12 V DC; 700
mA.
Mains transformer (UK)
Network interface
: DC transformer240V
AC/12 V DC; 700
mA.
: Analogue PBX or
PSTN, RJ-11.
Power supply and
network cable
: 7.5 metres, RJ-11
(line), EIAJ Class IV
(power).
ABOUT OREGON SCIENTIFIC
Recommended room
conditions
: Reverberation time:
<0.5 sec.
learn more about your voice recorder and other
Oregon Scientific products such as hand-held
organizers, alarm clocks, and weather stations.
The website also includes contact information for
our customer service department, in case you
need to reach us.
Background noise
Frequency response
Loudspeaker volume
: <45 dB(A).
: 200 – 3700 Hz.
: 85 dB SPL
(increased if extra
microphones are
used).
Room echo suppression
Line echo suppression
Automatic calibration
: 208 ms.
: 25 ms.
© 2004 Oregon Scientific. All rights reserved.
: <1 ms impulse (not
discernible).
Tape recorder output
: 3.5 mm tele jack.
Contact for con-
nection of tape
recorder may only be
connected to a SELV
voltage in accor
dance with SS-EN 60
950.
Dimensions
Weight
: Diameter 232 mm.
: 700 g.
Temperature range
Humidity
9
: 5 – 40°C in operation.
: 20 % – 80 % non-
manual-E.p65
12
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
manual-E.p65
13
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
0681
086-00XXXX-XXX
manual-E.p65
14
2004/5/18, PM 12:18
Download from Www.Somanuals.com. All Manuals Search And Download.
|