S I M P L Y
A M A Z I N G
USER’S GUIDE
2005HH
2005RH
COMMERCIAL
HIGH SPEED UPRIGHT VACUUM
CLEANER WITH
®
CLEANING SYSTEM
SAVE THIS BOOKLET!
Includes:
• Safety Warnings
• Warranty
• Operating Instructions
• Trouble Diagnosis
• Accessories
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessories
Maintenance and
Customer Service
(Sold Separately)
ITEM
PART NUMBER
Your ORECK vacuum cleaner is a product of
precise engineering. The motor bearings are
permanently lubricated and should not be oiled.
If you require additional information or have
problems with your ORECK appliance, or to order
new bags or spare parts, you may call ORECK
customer service at: (0) 01279 406995.
1. Dust Bag, 9 Pack
Hypo-Allergenic
PK80009DW
PK80009
0300604
AIRTABS
Regular
2. Belts, 3 Pack
®
3. Oreck Fresh Air Tabs
Or write to:
Oreck Commercial
21 Greenway Business Centre
Harlow Business Park, Greenway
HARLOW
Essex
U.K.
CM19 5QE
Please specify the model number and serial/code
number which can be found on the data plate on the
back of the vacuum.
Save your sales or purchase slip. Should your
ORECK appliance require warranty service, present
this slip to the Authorized Service Center as your
proof of purchase date.
Warranty
ORECK MANUFACTURING COMPANY: (Oreck 21180 Johnson Road;
Long Beach, MS, USA 39560 gives you the following warranty for this
product only if it was originally purchased for residential use, not resale
from Oreck or an Oreck Authorized Retail Dealer.)
Oreck will repair or replace, free of charge, to the original purchaser, any
part that is found to be defective in material or workmanship within one
(1) year of date of purchase. This limited warranty covers the revolving
roller brush for thirty (30) days from the date of purchase.
This warranty does not cover the replacement of expendable or
consumable parts such as carbon motor brushes, edge brushes, belts,
bulbs, disposable bags and other parts subject to normal wear unless
they are defective in material or workmanship.
This warranty does not apply to any part subjected to accident, abuse,
alteration, misuse, damage caused by act of God, the use of voltages
other than indicated on the serial number displayed on this product or
service of this product by other than Oreck or a participating Factory
Authorized Service Center.
Oreck does not authorize any person or representative to assume or
grant any other warranty obligation with the sale of this product.
Oreck’s warranty is valid only if you retain proof of purchase from Oreck
or an Oreck Authorized Retail Dealer for this product. If you purchase this
product from any other source, your purchase is “AS IS,” which means
Oreck grants you no warranty, and that you, not Oreck, assume the entire
risk of the quality and performance of this product, including the entire
cost of any necessary servicing or repairs of any defects.
This warranty is in addition to your statutory and other legal rights.
**Reconditioned units carry a 6 month warranty from date of purchase.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
To Replace Filter
Dust Bag
Assembly
To assist you in assembling your
cleaner, the parts have been
10
WARNING: Unplug cord from
electrical outlet before servicing.
11
numbered as follows
:
9
1 Handle section, upper
2 Tube, lower
3 Power head
1
12
BAG INSTALLATION:
17
16
1. Hook bottom of bag collar
opening under lip “B” of
connector assembly. Pull up
on bag collar and snap over
lip “A” of connector.
4 Outer bag
A
5 Paper filter dust bag
6 Power cord
5
13
2
4
8
B
7 Retaining spring
8 Bag tension bar
9 Zip fastener
10 On/off switch
11 Cord hook
6
2. Press on edges of bag collar
to insure bag is completely
installed.
12 Plastic loop/cable clamp
13 Connector assembly
14 Fan housing
14
7
15
15 Cord assembly
3
16 Handle Brace
17 Cord Strain Relief
Before assembling appliance,
1
remove two screws from connector
assembly. Remove cardboard
insert by pulling upward.
IMPORTANT: Check to
make sure bag collar is
behind lips “A” and “B”. If it
is not, dust will leak into
outer bag. When filter bag is
in place, close outer bag
with zipper fastener.
Connector
Assembly
With On/Off switch facing the
front of the unit, slide upper
Upper
2
Handle
handle section over matching
section of the connector assembly.
Place brace against handle and
connector assembly aligning
screw holes. Insert short screw into
top hole and long screw into
bottom hole then tighten firmly
until handle is no longer loose.
Using An Oreck
®
Fresh Air Tab
Brace
Your ORECK XL vacuum
cleaner has a special
FRESH AIR tab pocket. This
pocket is located inside the
outer bag in the area
where the disposable
paper bag attaches to the
intake tube. Insert tablet in
pocket.
Connector
Assembly
Attach cord to cord clip by
pressing cord above and below
clip ensuring the cord is fully rested
in clip.
3
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Operating Instructions
To Operate
All paper dust bags are not the same. Your ORECK
disposable dust bags have been designed to be
used with the ORECK cleaner. Using bags other
than genuine ORECK disposable bags will affect
the cleaning ability of your cleaner and could
cause damage to it.
Make sure the disposable paper filter dust bag is in place.
DO NOT operate the cleaner without a paper filter dust bag.
Plug the power cord into an electrical outlet.
Press the ON(l) - OFF(O) switch on handle assembly when
ready to operate.
General Information
The Belt
The performance of your new cleaner greatly depends upon
care and maintenance. The instructions in this manual will
guide you in performing basic care and maintenance. To
obtain the most satisfying years of service, read the
instructions and keep them handy for future reference.
The belt on your vacuum cleaner controls the speed of the
revolving brush and is very important for the effective
operation of the cleaner. If the belt becomes stretched or cut,
it will cause the revolving brush to stop completely or slow
down. See instructions in the manual for replacing belt.
An extra belt is stored in the baseplate of your
cleaner. When buying replacement belts, use ONLY
ORECK genuine belts. Belts other than ORECK belts
will not operate the revolving brush correctly and
may create undue stress which will cause damage
to the motor and brush bearings. Using belts other
than ORECK belts will void the warranty.
Operating Recommendations
This new ORECK XL High-Speed Upright is one of the finest,
fastest, and strongest units in its class. You’ll love the way it
cleans, gets under things, and it’s SO lightweight and easy to
use.
The following are a few simple suggestions regarding its
operation:
1. When inserting a new disposable paper filter dust bag—
FIRST PUFF OUT and OPEN THE BAG.
Lubrication
The vacuum cleaner motor bearings are factory lubricated
and sealed. Further lubrication is not required.
2. When the disposable filter dust bag is full, REPLACE IT.
3. If at any time the machine does not pick up properly or
makes an unusual noise, STOP OPERATION and service.
4. Although your upright will pick up pins, paper clips, and
other small objects, it is recommended that these be
removed from the floor before you vacuum. Failure to do
so may result in permanent damage to the motor suction
fan and its housing.
General Cleaner Care
At least once a month, check revolving brush for excessive
lint, string or hair. Remove this material.
Wipe the inside and outside
of the outer vinyl bag and the
outside of the cleaner with a
damp cloth. Also clean the
connector deflector assembly
area, base of cleaner and fan
housing area. If there is dust
in the outer bag, vacuum it or
shake it out.
A little preventative maintenance
will keep your cleaner looking
new and will ensure continued
cleaning effectiveness.
5. WARNING: Do not use your vacuum cleaner on damp
or wet surfaces. This will cause damage to the vacuum
cleaner and is dangerous to the user. Damage caused by
use on wet or damp surfaces is not covered under
warranty.
6. REPLACE THE BELT EVERY 6 MONTHS.
7. Change the disposable filter dust bag at least once a
month—even if it is not full! The collected dust in the dust
bag can cause odor, attract moisture, act as a breeding
area and can affect the efficiency of the cleaner.
8. Do not run the vacuum cleaner over cord. The
revolving brush could damage the cord.
9. Use caution when vacuuming over area rug edges and
fringe.
Cord Strain Relief
The cord strain relief located on the upper section of the handle
is designed to reduce stress on the cord at the base of the
handle.
Disposable Paper Filter Dust Bags
Disposable paper filter dust bags play a very important role
in the efficiency of your ORECK vacuum cleaner. The purpose
of the paper bag is to trap dirt, but at the same time it must
be porous enough to allow air to pass through. If the paper
bag becomes clogged, no air can pass through the cleaner
and cleaning cannot take place, regardless of the cleaner’s
power.
Should the power cord come
loose from the cord strain
relief, it can be easily
reattached.
To attach the power cord to
the cord strain relief, grasp the
Cord Strain
power cord approximately 12
Relief
To keep your cleaner operating at maximum efficiency,
change the dust bag frequently. DO NOT FILL ABOVE THE
LINE INDICATED ON THE DUST BAG.
Be sure the disposable paper filter dust bag is in proper
position, over the lower lip and the top lip of the connector.
inches from the base of the
Clamp
handle. Pinch power cord
together and slide approxi-
mately 1-2 inches through the
bottom hole in flat side of cord
strain relief. Carefully slide
power cord loop over clamp
on cord strain relief and pull
excess until the power cord is tightly rested under clamp.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
How to Replace a Worn Belt
Operating Instructions
WARNING: Unplug cord from
electrical outlet before servicing.
CAUTION—WOOD FLOORS, SOFT (VINYL, ASPHALT TILE,
ETC.) FLOOR SURFACES AND POLISHED FLOOR FINISHES
Use floor and floor finish manufacturer’s recommended
methods of cleaning. The metal strip on the base of the
cleaner could be damaged if used on concrete or abrasive
surfaces, and, therefore, cause damage to wood floors, soft
(vinyl, asphalt tile, etc.) floor surfaces and polished floor
finishes. The roller brush may also scuff very soft finishes. Do
not operate the unit while in the upright and locked position.
Do not let the unit run while in any one stationary position for
any period of time. Keep the unit moving while in operation.
Remove the replacement
belt from the storage
channel.
Celoc® Hypo-Allergenic Filter System: 2005HH
The CELOC SMMS outer bag of your vacuum cleaner is high
filtration medical material designed to filter the smallest of
dust particles. It is important the inside of the outer bag be
cleaned. Vacuum the inside of the outer bag or hand wash,
turned inside out, with warm water, and air dry. For best
results, the CELOC SMMS outer bag should be replaced
once a year. The CELOC layered disposable inner dust bag
must be replaced once a month even if it is not full.
Change it more often if it is used in extremely dirty areas.
Increase the cleaning power of your vacuum by changing the
bag often.
Remove the door by
removing the hold down
screw located on side of
power head.
Slide the door forward
by prying open with a
screwdriver or coin.
Remove the belt from the
brush roll pulley and the
motor drive shaft.
Loop the new belt over
the motor drive shaft.
Place the opposite end of
the belt on the brush roll
pulley. Rotate the brush
roll three (3) complete
revolutions to ensure that
no part of the belt is
overhanging the end of
the motor drive shaft.
Replace the door by
sliding it into the groove
at the bottom of the
housing. Replace the
hold down screw.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
To Adjust or Replace Brush
Stuffing or Blockage
Under certain conditions it is possible to stuff or block the intake
tube and the lower tube assembly. If your vacuum cleaner does
not pick up properly, or makes unusual noise and the outer bag
does not fluff up or balloon open, follow the following steps:
WARNING: Unplug cord from
electrical outlet before servicing.
To determine if the brush is
worn, place a firm straight
edge across the nozzle
opening. If brush bristles
do not extend beyond
baseplate, brush should be
adjusted.
WARNING: Unplug cord from electrical
outlet before servicing.
1. Check for blockage at the
mouth of the intake
opening. See illustration A.
If there is blockage, remove
it with long-nose pliers, a
screwdriver or coat hanger.
If you can not reach the
blockage, remove
Remove the baseplate by
removing 5 screws. Then,
remove the belt and brush
roll from the housing.
A
Intake Opening
baseplate. See illustration B.
2. If the blockage is not at the
base, remove lower tube.
See illustration C. Unhook
retainer spring, releasing
bottom of bag. Twist lower
collar counterclockwise to
slide up. Pull tube out of
base. Check for blockage.
If blockage is in the tube,
remove with a coat hanger.
3. If tube is not blocked, look
into fan housing. See illus-
tration D. Remove debris
with long-nose pliers, a
Rotate both bearing assem-
blies at ends of brush roll
to show “OLD” and
replace in the holding
channels in the housing.
Retainer
Spring
NOTE: The bearing
assembly setting marked
“OLD” has a smooth side.
The one marked “NEW”
C
has a notch. When
rotating bearings, make
sure both bearing
Rotate and match
bearing assemblies
screwdriver or coat hanger.
4. To reassemble, check O-ring
on tube, and replace if
Fan
Housing
assembly settings are the
same and face up when
replacing the brush roll.
damaged. Vacuum will not
operate properly without the
tube O-ring. Slide O-ring to
approximately 2" from base
of tube. Replace tube by
first lining up slot at base of
tube with inner tab inside
fan housing. Then reinsert
tube and push down until
the tube is seated. Make
sure O-ring is in place
O-ring
Reassemble the belt and
the baseplate and check
bristle height above
baseplate at each end of
brush.
D
E
against fan housing
opening. Replace and
If a previous adjustment
has already been made
and bristle height does not
extend above baseplate, a
new brush assembly
tighten collar until collar
locking tabs are locked in
place. See illustration E.
Make sure collar is not cross
threaded on housing.
IMPORTANT: Unless
the brush is worn as
indicated above,
both bearings must
be in the “NEW”
position. When
should be ordered.
rotating, both
bearings must be in
the ”OLD” position.
Unmatched settings
will cause damage
to your machine.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Stuffing or Blockage
Troubleshooting Guide
5. Many times blockage occurs
due to a full dust bag
WARNING: Unplug cord from
electrical outlet before servicing.
F
causing dirt to back down
Connector
Deflector
Opening
SAVE SERVICE CALLS...CHECK THESE FIRST:
• Is the disposable filter dust bag full?
the air flow system. When
that happens, the blockage
will be at the top of the
system, starting in the area
where the dust bag connects
to the connector assembly.
See illustration F.
• Are pores of filter dust bag clogged with powder or fine dust?
• Is anything clogging the revolving brush, lower tube, intake
opening, fan housing or connector assembly opening?
• Is the belt in place and turning the brush?
• Are the brush ends in the proper location?
• Does the brush turn freely? Are hair, string or rug fibers wound
around the brush?
PROBLEM
POSSIBLE SOURCE
AREAS TO CHECK
CLEANER
Not plugged in
properly.
Be sure cleaner is
firmly plugged
WILL NOT RUN
into wall outlet.
NOTE: If the Stuffing or Blockage instructions do not correct the
problem, contact an ORECK Authorized Service Center or call
the Commercial Customer Service Center at (0) 01279 406995.
No electricity in
wall outlet.
Check electrical
source–fuse or
circuit breaker.
CLEANER
Filter bag is full.
Replace filter bag.
See “To Replace
Paper Filter Dust
Bag.”
DOES NOT PICK UP
IMPORTANT: On plush and new carpets, stuffing may occur
due to excessive fuzz and loose cuttings in the carpet.
Stuffing could occur for the first few cleanings until all the
loose material is removed. Due to the high efficiency of the
cleaner, many older carpets will cause stuffing when the
cleaner is first used on them.
Nozzle or intake
pivot clogged.
Clear obstruction.
Belt is broken or
stretched.
Replace belt.
Brush is worn.
See “To Adjust or
Replace Brush.”
Bag tube clogged. Clear obstruction.
Bag pores are
clogged with fine
dust.
Change bag.
Impeller fan is
broken.
Return to Service
Center for repair.
Revolving brush is Check brush roll
not even at both
ends.
end cards. Make
sure words “OLD”
or “NEW” match
at each end.
ALL OTHER SERVICING SHOULD BE DONE BY AN
ORECK AUTHORIZED SERVICE CENTER.
COMMERCIAL CUSTOMER SERVICE
(0) 01279 406995
Whenever calling, please be sure to have your model and
serial number from data plate.
©2005 Oreck Holdings, LLC. All rights reserved. All word marks, logos, product configurations, and registered trademarks are owned and used under the authority of Oreck Holdings,
LLC. Printed in America.
75319-10 REV A
11/05 ECN# R-8058 & 8199
Download from Www.Somanuals.com. All Manuals Search And Download.
|