OPTI UPS Power Supply SP2L User Manual

* SP8L  
* SP4L  
* SP8H  
* SP2L  
Smart Power Series - SP2L / SP4L / SP8H / SP8L  
Remote Control Surveillance Management System  
Features  
* Control Power Switch of Remote Equipment via network or phone voice to replace the presence of the personnel  
* LED face board to inspect current equipment ID, Main Current and each Router Current directly  
* Execute Power On / Off Reboot via console to manage its performance  
* Detect whether two sets of power circuit are normal automatically  
* It can be linked with 16 sets monitors at maximum to control up to 128 sets of connected devices  
* It can be attached temperature detector to control the power switch according to environment change  
* It is equipped with overloading electric breaking protector to avoid overloading to cause device damage  
* Support nearby Manual Power Switch  
* Support Wake on Ring function. ATX equipment can be started normally  
* Provide 20 sets of accounts and passwords for your own setting to manage different power switches  
* Record the user’s operating message and abnormal message to provide the user to check the case afterwards  
* Support Power Start sequence setting to prevent all of switches from starting simultaneously to cause sudden  
overloading and effect equipment working  
* Provide API interface. The manager can develop the control software by himself  
* Support Windows, Linux to execute the safety shutdown and avoid system damage  
* Pre-set Switch Start Time and arrange the working schedule for power supply  
* Each rout can detect UPS low power signal to provide safety shutdown management for the equipment  
* Detect whether the power current of all routes are normal or not to avoid current overloading to damage the device  
* By brief message and email warning to practice the instant surveillance and warning to important equipment  
* Provide remote net firmware to renew the function  
* Provide the function of IP and MAC address filter that prevent unauthorized user from access the device  
Digital Monitor PDU for the cabinet of Datacenter  
Features  
* The Master or Slave that setup in the cabinet can connect up to 6 unit PDU  
* The Master/Slave RJ45 socket in the back end can connect 6 PDU  
* The Master/Slave has 6 button that sign 1-6 separately. It can check all connected PDU’s current.  
The scan button can show every connected PDU’s current alternately  
* The Master/Slave build-in the sensor of temperature/humidity and show it on LCD panel.  
Administrator can learned about temperature/humidity of cabinet from LCD panel  
* Every Slave can daisy-chain to Master by the RJ11 PORT(UP&DOWN) in the front end.  
Any of Slave breakdown don’t affect other Slave’s data transmitter, all Slave’s data will bypass to the Master  
Master1......Master8  
Central monitor software  
62.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Washer 09 848 440 User Manual
Miele Washer W 2809i User Manual
Milwaukee Cordless Sander 6117 30 User Manual
Network Appliance Network Card Reseller Partner Program User Manual
NHT Speaker iW3 User Manual
Oreck Vacuum Cleaner U3760HH User Manual
Palsonic Flat Panel Television 76WSHDA User Manual
Panasonic Electric Shaver ES2045 User Manual
Panasonic Projector ET DFD75 User Manual
Panasonic Switch AB5 User Manual