VM-94137N
Revised 09-96
Section 65
Wiring Instructions for
(00-02-0209)
®
VM-12 and VM-24 Voltmeter
■ Frank W. Murphy Manufacturer
Please read these instructions carefully
before installing.
P.O. Box 470248; Tulsa, Oklahoma 74147; USA
tel. (918) 627-3550 fax (918) 664-6146
e-mail [email protected]
Voltmeter
Light
Switch
†
(rear view )
Lamp
1. Disconnect battery ground cable.
■ Frank W. Murphy Southern Division
P.O. Box 1819; Rosenberg, Texas 77471; USA
tel. (713) 342-0297 fax (713) 341-6006
2. Connect an 18 AWG (1.0 mm2) wire, minimum, from
the ground terminal on the back of the voltmeter to
ground (see wiring diagram). For an above ground
■ Frank W. Murphy, Ltd.
ON–OFF
Switch
Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
tel. +44 1722 410055 fax +44 1722 410088 tlx 477088
e-mail [email protected]
system connect the wire from the “–”
terminal on the
No
Connection
To Electrical
System
.
voltmeter to the negative (–) terminal on the battery
3. Connect an 18 AWG (1.0 mm2) wire, minimum,
from the “IGN” terminal on the ignition switch to
the “+” terminal on back of the voltmeter.
■ Frank W. Murphy Pte., Ltd.
26 Siglap Drive; Republic of Singapore 456153
tel. +65 241-3166 fax +65 241-8382
Battery
Cable
■ Murphek Pty., Ltd.
4. Connect an 18 AWG (1.0 mm2) wire, minimum,
from the instrument panel’s lighting circuit to the
illuminating lamp on back of the voltmeter (if
applicable).
1620 Hume Highway; Campbellfield, Vic 3061; Australia
tel. +61 3 9358-5555 fax +61 3 9358-5556
Starter
Motor
■ Murphy de México, S.A. de C.V.
Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
Battery
Alternator
tel. +52-48-206264 fax +52-48-206336
†
5. Reconnect battery ground cable.
Terminal location may differ from shown.
■ Murphy Switch of California
P.O. Box 900788; Palmdale, California 93590; USA
tel. (805) 272-4700 fax (805) 947-7570
e-mail [email protected]
■ Frank W. Murphy France
tel. +33 1 30 762626 fax +33 1 30 763989
Download from Www.Somanuals.com. All Manuals Search And Download.
|