N Tron Switch 105FX POE User Manual

105TX-POE & 105FX-POE  
Unmanaged Industrial Ethernet  
POE Switches  
User Manual &  
Installation  
Guide  
Rev. 041008  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
Copyright, © N-TRON Corp., 2008  
820 S. University Blvd., Suite 4E  
Mobile, AL USA 36609  
All rights reserved. Reproduction, adaptation, or translation without prior written permission from N-TRON  
Corp. is prohibited, except as allowed under copyright laws.  
Ethernet is a registered trademark of Xerox Corporation. All other product names, company names, logos  
or other designations mentioned herein are trademarks of their respective owners.  
The information contained in this document is subject to change without notice. N-TRON Corp. makes no  
warranty of any kind with regard to this material, including, but not limited to, the implied warranties of  
merchantability or fitness for a particular purpose. In no event shall N-TRON Corp. be liable for any  
incidental, special, indirect or consequential damages whatsoever included but not limited to lost profits  
arising out of errors or omissions in this manual or the information contained herein.  
Contact Information :  
N-TRON Corp.  
820 South University Blvd.  
Suite 4E  
Mobile, AL 36609  
TEL: (251) 342-2164  
FAX: (251) 342-6353  
Rev. 041008  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
GENERAL SAFETY WARNINGS  
WARNING: Do not operate the equipment in the presence of flammable gasses or fumes. Operating  
electrical equipment in such an environment constitutes a definite safety hazard.  
WARNING: If the equipment is used in the manner not specified by N-TRON Corp., the protection provided  
by the equipment may be impaired.  
WARNING: Do not perform any services on the unit unless qualified to do so. Do not substitute  
unauthorized parts or make unauthorized modifications to the unit.  
WARNING: Do not operate the unit with the end plates removed, as this could create a shock or fire  
hazard.  
WARNING: Do not operate the equipment in a manner not specified by this manual.  
ENVIRONMENTAL SAFETY WARNINGS  
WARNING: Disconnect the power and allow to cool 5 minutes before touching.  
ELECTRICAL SAFETY WARNINGS  
WARNING: Disconnect the power cable before removing the end plates.  
WARNING: Do not operate the unit with the end plates removed.  
WARNING: Do not work on equipment or cables during periods of lightning activity.  
WARNING: Do not perform any services on the unit unless qualified to do so.  
WARNING: Observe proper DC Voltage polarity when installing power input cables. Reversing voltage  
polarity can cause permanent damage to the unit and void the warranty.  
Rev. 041008  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
HAZARDOUS LOCATION INSTALLATION REQUIREMENTS  
1. This equipment is suitable for use in Class I, Div 2, Groups A, B, C, and D, or unclassified or non-  
hazardous locations only.  
2. WARNING: Explosion Hazard - Substitution of components may impair suitability for Class I,  
Division 2.  
3. WARNING: Explosion hazard, do not disconnect while the circuit is live or unless the area is known to be  
non-hazardous.  
4. WARNING: Explosion Hazard - Do not remove or replace the device unless power has been switched off  
or the area is known to be non-hazardous.  
5. Use 60/75ºC rated Copper wire, (0.22Nm) 2 inch-lbs Tightening torque for field installed connectors.  
6. WARNING: Install only in accordance with Local & National Codes of Authorities Having Jurisdiction.  
7. Class I, Div 2 installations require that all devices connected to this product must be UL listed for the area in  
which it is installed.  
8. WARNING: Damage may occur to the RJ-45 port of the powered device (PD), if the switch is not  
powered down before disconnecting the Cat5 cable.  
Rev. 041008  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Functional Overview  
The 105TX-POE and 105FX-POE Power over Ethernet Unmanaged Industrial Ethernet Switches are  
designed to provide power over Ethernet for POE capable devices where running a power line is either not  
possible or not cost effective. This feature allows an end user to power a POE camera, wireless access  
point, or any other POE capable device without the need for running separate wires for power. This also  
allows the ability for a centralized battery backup for all these devices.  
The 105FX-POE utilizes the IEEE compliant SC or ST duplex connectors for fiber optic communication.  
All 10/100Base-TX ports utilize the RJ45 shielded connectors.  
Key Features  
Compact, space saving package  
Full IEEE 802.3 & 100Base-FX Compliance  
IEEE 802.3af Compliant  
105TX-POE - Five 10/100Base-TX RJ-45 ports (4 PSE ports and 1 uplink port)  
105FX-POE - Four 10/100Base-TX RJ-45 ports (4 PSE ports and 1 100BaseFX fiber uplink port)  
Unmanaged operation  
Extended Environmental Specifications  
-40°C to 85°C Operating Temperature  
-40°C to 85°C Storage Temperature  
Operating Humidity: 10% to 90% (Non Condensing)  
Support for Full/Half Duplex Operation  
LED Link/Activity Status Indication  
LED POE Status Indication  
Power Fault Status LEDs  
Auto-negotiation, Auto-sensing Speed, Duplex, and Flow Control  
Up to 1.0 Gb/s Maximum Throughput  
Industry Standard 35mm DIN Rail Mounted Enclosure  
Redundant power inputs (46-49 VDC)  
Supports up to 15.4Watts per channel (13 Watts at the Powered Device (PD ))  
Full wire speed communications  
Hardened metal DIN Rail Enclosure  
Rev. 041008  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
PACKAGE CONTENTS  
Please make sure the switch package contains the following items:  
1.  
2.  
105TX-POE or 105FX(E)-POE  
Instruction Sheet  
Contact your carrier if any items are damaged.  
UNPACKING  
Remove all the equipment from the packaging, and store the packaging in a safe place. File any damage  
claims with the carrier.  
CLEANING  
Clean only with a damp cloth.  
INSTALLATION  
Read the following warnings before beginning the installation:  
WARNING  
Never install or work on electrical equipment or cabling during periods of lightning activity. Never connect  
or disconnect power when hazardous gasses are present.  
LASER SAFETY (105FXE -40 and -80 Only)  
WARNING: CLASS 1 LASER PRODUCT. Do not stare into the laser.  
Rev. 041008  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIN-Rail Mounting  
Install the unit in a standard DIN rail. Recess the unit to allow at least 2” of horizontal clearance for CAT5e  
cable bend radius.  
To install the unit to 35mm industrial DIN rail,  
place the top edge of the included mounting  
bracket on the back of the unit against the DIN  
rail at a 15° angle as shown. Rotate the bottom of  
the unit to the back (away from you) until it  
snaps into place.  
To remove the unit from the 35mm industrial  
DIN rail, place a flat head screwdriver into the  
release clip found at the bottom of the unit, and  
apply downward force on the clip until it  
disengages from the bottom of the unit from the  
DIN rail. Rotate the bottom of the unit towards  
you and up at an approximate 15° upward angle  
to completely remove the unit.  
Most N-Tron™ products are  
designed to be mounted on industry  
standard 35mm DIN rail. However,  
DIN rail mounting may not be  
suitable for all applications. Our Rack  
Mount Assembly (P/N: 900-RM)  
may be used to mount the  
105TX/FX-POE  
enclosures  
to  
standard 19" racks as an option.  
Rev. 041008  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
FRONT PANEL  
From Top to Bottom:  
Power LED  
POE  
POE Status LED  
SPD  
LNK/ACT  
RJ45 Ports  
Speed LED (105TX-POE only)  
Link/Activity LED  
Auto sensing 10/100BaseT Connection  
LED MODE OF OPERATION  
Note: Redundant power inputs will not balance the power load. Only load from one power supply is used  
at a time.  
Rev. 041008  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
APPLYING POWER (Top View)  
Unscrew & Remove the DC Voltage Input Plug from the top header.  
Install the DC Power Cables into the Plug (observing polarity on unit).  
Plug the Voltage Input Plug back into the top header.  
Tightening torque for the terminal block power plug is 0.22 Nm/0.162 Pound Foot.  
Turn the power on the wire.  
Note: It is only safe to turn the power on the wires after the wires have been secured to the  
switch.  
WARNING: Inserting the input plug while the 48VDC is applied may cause arcing, and damage  
the input connector permanently.  
Note: Either V1 or V2 can be connected to power for minimal operation. For redundant power  
operation, V1 and V2 plugs must be connected to separate DC Voltage sources. Use wire sizes of 10-20  
gauge. The power cord should be limited to less than 10 meters in order to ensure optimum  
performance.  
Recommended 48V DC Power Supplies, similar to:  
100-240VAC:  
N-Tron NTPS-48-5, DC 48V/5A  
Rev. 041008  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-TRON GROUNDING TECHNIQUES FOR 105TX-POE AND 105FX-POE  
The grounding philosophy of any control system is an integral part of the design. N-Tron switches are designed  
to be grounded, but the user has been given the flexibility to float the switch when required. The best noise  
immunity and emissions (i.e. CE) are obtained when the N-Tron switch chassis is connected to earth ground via  
a drain wire. Some N-Tron switches have metal din-rail brackets that can ground the switch if the din-rail is  
grounded. In some cases, N-Tron switches with metal brackets can be supplied with optional plastic brackets if  
isolation is required.  
Users may run a drain wire & lug from the screw provided on the back face of the  
enclosure. In the event the provided grounding screw has been lost, care should  
be taken to limit the penetration of the outer skin by less than 1/4". Failure to do  
so may cause irreversible damage to the internal components of the switch.  
Note: Ensure the power supply is grounded properly before applying power to the  
grounded switch. This may be verified by using a voltmeter to determine that  
there is no voltage difference between the power supply’s negative output terminal  
and the chassis grounding point of the switch.  
As an alternative grounding method, both V- legs of the power input  
connector are connected to chassis internally on the PCB. Connecting  
a drain wire to earth ground from one of the V- terminal plugs as  
shown here will ground the switch and the chassis. The power leads  
from the power source should be limited to 3 meters or less in length.  
If the use of shielded cables is required, it is generally recommended to only connect the shield at one end to  
prevent ground loops and interfere with low level signals (i.e. thermocouples, RTD, etc.). Cat5e cables  
manufactured to EIA-568A or 568B specifications are required for use with N-Tron Switches.  
In the event all Cat5e patch cable distances are small (i.e. All Ethernet devices are located the same local  
cabinet and/or referenced to the same earth ground), it is permissible to use fully shielded cables terminated to  
chassis ground at both ends in systems void of low level analog signals.  
Rev. 041008  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RJ45 CONNECTOR CRIMP SPECIFICATIONS  
Please reference the illustration below for your Cat5 cable specifications:  
Rev. 041008  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TYPICAL APPLICATIONS  
STAR TOPOLOGY  
Rev. 041008  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RING TOPOLOGY  
Rev. 041008  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CONNECTING THE UNIT  
For the 100BaseFX Fiber Optic port (105FX-POE), remove the dust cap(s) from the fiber optic connector and  
connect the fiber optic cables. The TX port on the local unit should be connected to the RX port of the far end  
device, and the RX port should be connected to the TX port of the far end device.  
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector. For  
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the RJ45 connector. Connect the  
other end to the far end station. Verify that the LNK LED’s are ON once the connection has been  
completed. To connect any other port to another Switch or Repeater, use a standard Cat5 straight through or  
crossover cable.  
Warning: Creating a port to port connection on the same switch (i.e. loop) is an illegal operation and will  
create a broadcast storm which will crash the network!  
TROUBLESHOOTING  
1. Make sure the (Power LED) is ON.  
2. Make sure you are supplying sufficient current for the 105TX-POE or 105FX-POE and all powered  
devices plugged into it. Note: The inrush current and steady state current is dependent on the  
power requirements of the powered devices plugged into the POE switch.  
3. Verify that the POE light is on solid if a valid POE PD is connected to the port.  
4. Verify that Link LED’s are ON for both ports.  
5. Verify cabling used between stations.  
6. Verify that cabling is Category 3 or greater for 10Mbit Operation.  
Rev. 041008  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FCC STATEMENT  
This product complies with Part 15 of the FCC-A Rules.  
Operation is subject to the following conditions:  
(1) This device may not cause harmful interference  
(2) This device must accept any interference received, including interference that may cause undesired  
operation.  
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,  
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  
harmful interference in a residential installation. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful  
interference to radio communications. Operation of this device in a residential area is likely to cause  
harmful interference in which case the user will be required to correct the interference at his own expense.  
INDUSTRY CANADA  
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment  
Regulations. Operation is subject to the following two conditions; (1) this device digital apparatus meets all  
requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the  
following two conditions; (1) this device may not cause harmful interference, and (2) this device must  
accept any interference received, including interference that may cause undesired operation.  
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant  
des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne  
pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y  
compris l'interférence qui peut causer l'opération peu désirée.  
Rev. 041008  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Regulatory Approvals:  
Safety: UL Listed per ANSI/ISA-12.12.01-2000 (US and Canada)  
This apparatus is suitable for use in Class I, Div 2, Groups A, B, C, D, T4  
EMI: EN 61000-6-4, EN 55011 - Class A  
FCC Title 47, Part 15, Subpart B - Class A  
ICES-003 – Class A  
EMS: EN6 1000-6-2  
IEC 61000-4-2 (ESD)  
IEC 1000-4-3 (RS)  
IEC 61000-4-4 (EFT)  
IEC 61000-4-5 (Surge)  
IEC 61000-4-6 (Conducted Disturbances)  
Warranty: 3 years from the date of purchase.  
Rev. 041008  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
KEY SPECIFICATIONS  
Physical  
Height:  
Width:  
3.50” (8.89 cm.)  
1.50” (3.81 cm.)  
4.22” (10.72 cm)  
0.70 lbs. (0.32 kg)  
Depth Including Din-Rail Clip:  
Weight:  
Electrical  
Input Voltage:  
Input Current:  
46-49 VDC  
1.6 A @ 48 VDC (under full load)  
65 mA @ 48 VDC (no POE in use, switch in full use)  
26 Amp/1.3 ms @ 48VDC  
Less than 100 mV  
Inrush Current:  
Input Ripple:  
Input Wire Size:  
10-20 AWG  
Environmental  
Operating Temperature:  
Storage Temperature:  
Operating Humidity:  
Operating Altitude:  
-40°C to 85°C  
-40°C to 85°C  
10% to 90% (Non Condensing)  
0 to 10,000 ft.  
Network Media  
10BaseT:  
> Cat-3 Cable  
100BaseT:  
> Cat-5 Cable  
100BaseFX:  
Multimode: 50-62.5/125µm Fiber  
Singlemode: 7-10/125µm Fiber  
Fiber Transceiver Characteristics  
Fiber Length:  
2km*  
15km**  
40km**  
80km**  
TX Power Min/Max -19dBm/-14dBm -15dBm/-7dBm -5dBm/0dBm  
-5dBm/0dBm  
-34dBm  
RX Sensitivity Max: -32dBm  
Wavelength:  
1310nm  
-34dBm  
1310nm  
-34dBm  
1310nm  
1550nm  
*=Multimode ** =Singlemode  
Connectors  
10/100BaseTX:  
100BaseFX:  
RJ45 UTP Port  
SC or ST Duplex Port  
Recommended Minimum Wiring Clearance:  
Front: 2” (5.08 cm)  
Top: 1" (2.54 cm)  
Rev. 041008  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
N-TRON Limited Warranty  
N-TRON, Corp. warrants to the end user that this hardware product will be free from defects in workmanship and materials,  
under normal use and service, for the applicable warranty period from the date of purchase from N-TRON or its authorized  
reseller. If a product does not operate as warranted during the applicable warranty period, N-TRON shall, at its option and  
expense, repair the defective product or part, deliver to customer an equivalent product or part to replace the defective item, or  
refund to customer the purchase price paid for the defective product. All products that are replaced will become the property of  
N-TRON. Replacement products may be new or reconditioned. Any replaced or repaired product or part has a ninety (90) day  
warranty or the remainder of the initial warranty period, whichever is longer. N-TRON shall not be responsible for any custom  
software or firmware, configuration information, or memory data of customer contained in, stored on, or integrated with any  
products returned to N-TRON pursuant to any warranty.  
OBTAINING WARRANTY SERVICE: Customer must contact N-TRON within the applicable warranty period to obtain  
warranty service authorization. Dated proof of purchase from N-TRON or its authorized reseller may be required. Products  
returned to N-TRON must be pre-authorized by N-TRON with a Return Material Authorization (RMA) number marked on the  
outside of the package, and sent prepaid and packaged appropriately for safe shipment. Responsibility for loss or damage does not  
transfer to N-TRON until the returned item is received by N-TRON. The repaired or replaced item will be shipped to the  
customer, at N-TRON’s expense, not later than thirty (30) days after N-TRON receives the product. N-TRON shall not be  
responsible for any software, firmware, information, or memory date of customer contained in, stored on, or integrated with any  
products returned to N-TRON for repair, whether under warranty or not.  
ADVANCE REPLACEMENT OPTION: Upon registration, this product qualifies for advance replacement. A replacement  
product will be shipped within three (3) days after verification by N-TRON that the product is considered defective. The  
shipment of advance replacement products is subject to local legal requirements and may not be available in all locations. When  
an advance replacement is provided and customer fails to return the original product to N-TRON within fifteen (15) days after  
shipment of the replacement, N-TRON will charge customer for the replacement product, at list price.  
WARRANTIES EXCLUSIVE: IF AN N-TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE,  
CUSTOMER'S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR, REPLACEMENT, OR  
REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. TO THE FULL EXTENT ALLOWED BY LAW, THE  
FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES,  
TERMS, OR CONDITIONS, EXPRESS OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR  
OTHERWISE, INCLUDING WARRANTIES, TERMS, OR CONDITIONS OF MERCHANTABILITY, FITNESS FOR A  
PARTICULAR PURPOSE, SATISFACTORY QUALITY, CORRESPONDENCE WITH DESCRIPTION, AND NON-  
INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED. N-TRON NEITHER ASSUMES NOR AUTHORIZES  
ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE,  
INSTALLATION, MAINTENANCE OR USE OF ITS PRODUCTS. N-TRON SHALL NOT BE LIABLE UNDER THIS  
WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THAT THE ALLEGED DEFECT OR MALFUNCTION  
IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER'S OR ANY THIRD PERSON'S MISUSE,  
NEGLECT, IMPROPER INSTALLATION OR TESTING, UNAUTHORIZED ATTEMPTS TO OPEN, REPAIR OR MODIFY  
THE PRODUCT, OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE, OR BY ACCIDENT, FIRE,  
LIGHTNING, POWER CUTS OR OUTAGES, OTHER HAZARDS, OR ACTS OF GOD.  
LIMITATION OF LIABILITY: TO THE FULL EXTENT ALLOWED BY LAW, N-TRON ALSO EXCLUDES FOR ITSELF  
AND ITS SUPPLIERS ANY LIABILITY, WHETHER BASED IN CONTRACT OR TORT (INCLUDING NEGLIGENCE),  
FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY KIND, OR FOR  
LOSS OF REVENUE OR PROFITS, LOSS OF BUSINESS, LOSS OF INFORMATION OR DATA, OR OTHER FINANCIAL  
LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE, INSTALLATION, MAINTENANCE, USE,  
PERFORMANCE, FAILURE, OR INTERRUPTION OF ITS PRODUCTS, EVEN IF N-TRON OR ITS AUTHORIZED  
RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, AND LIMITS ITS LIABILITY TO  
REPAIR, REPLACEMENT, OR REFUND OF THE PURCHASE PRICE PAID, AT N-TRON'S OPTION. THIS DISCLAIMER  
OF LIABILITY FOR DAMAGES WILL NOT BE AFFECTED IF ANY REMEDY PROVIDED HEREIN SHALL FAIL OF  
ITS ESSENTIAL PURPOSE.  
DISCLAIMER: Some countries, states, or provinces do not allow the exclusion or limitation of implied warranties or the  
limitation of incidental or consequential damages for certain products supplied to consumers or the limitation of liability for  
personal injury, so the above limitations and exclusions may be limited in their application to you. When the implied warranties  
are not allowed to be excluded in their entirety, they will be limited to the duration of the applicable written warranty. This  
warranty gives you specific legal rights which may vary depending on local law.  
GOVERNING LAW: This Limited Warranty shall be governed by the laws of the State of Alabama, U.S.A.  
Rev. 041008  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Minox Digital Camera DC8022 User Manual
MTD Chipper 247 462B000 User Manual
Multi Tech Systems Network Card MultiModem DID User Manual
Napoleon Fireplaces Air Cleaner WF 6 9 18 User Manual
National Instruments Dryer Accessories SCC LP01 User Manual
NetComm Network Router NB6 User Manual
Norcold Refrigerator N61X User Manual
Oregon Scientific Clock Radio RM901A User Manual
Oster Blender Designer Series Push Button Blenders User Manual
Panasonic Answering Machine KX TG9391 User Manual