Miller Electric Welder Spectrum 1000 User Manual

OM-217  
168 808F  
October 1998  
Processes  
Air Plasma Cutting  
and Gouging  
Description  
Air Plasma Cutter  
R
Spectrum 1000 And 1250  
Visit our website at  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Plasma Arc Cutting Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .  
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 1 – CONSIGNES DE SÉCURITÉ – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .  
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-2. Dangers liés au coupage à l’arc au plasma . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
1
1
3
4
4
5
5
5
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement  
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7
7
8
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
SECTION 2 – DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-1. Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-2. Manufacturer’s Rating Label For CE Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
2-3. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
9
9
11  
12  
SECTION 3 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12  
3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-2. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-3. Cutting Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-4. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-5. Dimensions And Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-6. Tipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-7. Connecting Work Clamp And Gas/Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-8. Remote Control Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-9. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
3-10. Placing Jumper Links And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
12  
13  
13  
14  
15  
15  
16  
17  
18  
19  
SECTION 4 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
4-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
SECTION 5 – MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21  
5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-2. Overload Protection: Fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-3. Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System . . . . . . . . . .  
5-4. Adjusting Spark Gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-5. Torch And Work Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
5-6. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
21  
22  
23  
24  
25  
26  
SECTION 6 – ELECTRICAL DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28  
SECTION 7 – HF IN PLASMA CUTTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30  
7-1. High Frequency In Plasma Arc Cutting (PAC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
7-2. Sources Of High-Frequency Radiation From Incorrect Installation . . . . . . . . . . . . . . . . . . . . .  
7-3. Correct Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
30  
30  
31  
SECTION 8 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32  
WARRANTY  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Declaration of Conformity For  
European Community (CE) Products  
This information is provided for units with CE certification (see rating label on unit.)  
NOTE  
Manufacturer’s Name:  
Miller Electric Mfg. Co.  
Manufacturer’s Address:  
1635 W. Spencer Street  
Appleton, WI 54914 USA  
Declares that the product:  
Spectrum 1000 &1250  
conforms to the following Directives and Standards:  
Directives  
Low Voltage Directive: 73/23/EEC  
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC  
Electromagnetic Compatibility Directives: 89/336/EEC, 92/31/EEC  
Standards  
Arc Welding Equipment, Plasma Cutting Systems: prEN 50192: 1995  
Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1990  
Arc Welding Equipment Part 1: Welding Power Sources: IEC 974-1  
(April 1995 – Draft revision)  
Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989  
Insulation coordination for equipment within low-voltage systems:  
Part 1: Principles, requirements and tests: IEC 664-1: 1992  
Electromagnetic compatibility (EMC) Product standard for arc welding equipment:  
EN50199: August 1995  
European Contact:  
Mr. Luigi Vacchini, Managing Director  
MILLER Europe S.P.A.  
Via Privata Iseo  
20098 San Giuliano  
Milanese, Italy  
Telephone:  
Fax:  
39(02)98290-1  
39(02)98281-552  
dec_con1 10/95  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE  
USING  
pom _nd_5/97  
1-1. Symbol Usage  
Means Warning! Watch Out! There are possible hazards  
with this procedure! The possible hazards are shown in  
the adjoining symbols.  
Y
Marks a special safety message.  
This group of symbols means Warning! Watch Out! possible  
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.  
Consult symbols and related instructions below for necessary actions  
to avoid the hazards.  
. Means Note; not safety related.  
1-2. Plasma Arc Cutting Hazards  
Y
The symbols shown below are used throughout this manual to  
call attention to and identify possible hazards. When you see  
the symbol, watch out, and follow the related instructions to  
avoid the hazard. The safety information given below is only  
a summary of the more complete safety information found in  
the Safety Standards listed in Section 1-4. Read and follow all  
Safety Standards.  
ELECTRIC SHOCK can kill.  
Touching live electrical parts can cause fatal shocks  
or severe burns. The torch and work circuit are  
electrically live whenever the output is on. The input  
power circuit and machine internal circuits are also  
live when power is on. Plasma arc cutting requires  
higher voltages than welding to start and maintain the arc (200 to 400  
volts dc are common), but also uses torches designed with safety  
interlock systems which turn off the machine when the shield cup is  
loosened or if tip touches electrode inside the nozzle. Incorrectly  
installed or improperly grounded equipment is a hazard.  
Y
Y
Only qualified persons should install, operate, maintain, and  
repair this unit.  
During operation, keep everybody, especially children, away.  
D
Do not touch live electrical parts.  
CUTTING can cause fire or explosion.  
D
D
Wear dry, hole-free insulating gloves and body protection.  
Hot metal and sparks blow out from the cutting arc.  
The flying sparks and hot metal, hot workpiece, and  
hot equipment can cause fires and burns. Check  
and be sure the area is safe before doing any cutting.  
Insulate yourself from work and ground using dry insulating mats or  
covers big enough to prevent any physical contact with the work or  
ground.  
D
D
D
Do not touch torch parts if in contact with the work or ground.  
Turn off power before checking, cleaning, or changing torch parts.  
D
D
D
Protect yourself and others from flying sparks and hot metal.  
Do not cut where flying sparks can strike flammable material.  
Disconnect input power before installing or servicing this equip-  
ment. Lockout/tagout input power according to OSHA CFR  
1910.147(see Safety Standards).  
Remove all flammables within 35 ft (10.7 m) of the cutting arc. If this  
is not possible, tightly cover them with approved covers.  
D
D
Properly install and ground this equipment according to its Owners  
Manual and national, state, and local codes.  
D
Be alert that sparks and hot materials from cutting can easily go  
through small cracks and openings to adjacent areas.  
Check and be sure that input power cord ground wire is properly  
connected to ground terminal in disconnect box or that cord plug is  
connected to a properly grounded receptacle outlet always verify  
the supply ground.  
D
D
Watch for fire, and keep a fire extinguisher nearby.  
Be aware that cutting on a ceiling, floor, bulkhead, or partition can  
cause fire on the hidden side.  
D
D
Do not cut on closed containers such as tanks or drums.  
D
D
When making input connections, attach proper grounding conduc-  
tor first.  
Connect work cable to the work as close to the cutting area as prac-  
tical to prevent cutting current from traveling long, possibly  
unknown paths and causing electric shock and fire hazards.  
Frequentlyinspect input power cord for damage or bare wiring re-  
place cord immediately if damaged bare wiring can kill.  
D
Never cut containers with potentially flammable materials inside –  
they must be emptied and properly cleaned first.  
D
D
D
D
Turn off all equipment when not in use.  
Inspect and replace any worn or damaged torch cable leads.  
Do not wrap torch cable around your body.  
D
D
D
D
Do not cut in atmospheres containing explosive dust or vapors.  
Do not cut pressurized cylinders, pipes, or vessels.  
Do not cut containers that have held combustibles.  
Ground the workpiece to a good electrical (earth) ground if required  
by codes.  
Wear oil-free protective garments such as leather gloves, heavy  
shirt, cuffless trousers, high shoes, and a cap.  
D
Use only well-maintained equipment. Repair or replace damaged  
parts at once.  
D
D
Do not locate unit on or over combustible surfaces.  
D
D
Wear a safety harness if working above floor level.  
Keep all panels and covers securely in place.  
Remove any combustibles, such as a butane lighter or matches,  
from your person before doing any cutting.  
OM-217 Page 1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D
D
D
D
Do not bypass or try to defeat the safety interlock systems.  
Use only torch(es) specified in Owners Manual.  
D
D
Keep your head out of the fumes. Do not breathe the fumes.  
If inside, ventilate the area and/or use exhaust at the arc to remove  
cutting fumes and gases.  
Keep away from torch tip and pilot arc when trigger is pressed.  
D
D
If ventilation is poor, use an approved air-supplied respirator.  
Clamp work cable with good metal-to-metal contact to workpiece  
(not piece that will fall away) or worktable as near the cut as  
practical.  
Read the Material Safety Data Sheets (MSDSs) and the manufac-  
turers instruction for metals to be cut, coatings, and cleaners.  
D
Insulate work clamp when not connected to workpiece to prevent  
contact with any metal object.  
D
Work in a confined space only if it is well ventilated, or while wearing  
an air-supplied respirator. Fumes from cutting and oxygen deple-  
tion can alter air quality causing injury or death. Be sure the  
breathingair is safe.  
SIGNIFICANT DC VOLTAGE exists after removal  
of input power on inverters.  
D
D
Do not cut in locations near degreasing, cleaning, or spraying oper-  
ations. The heat and rays of the arc can react with vapors to form  
highly toxic and irritating gases.  
D
Turn OFF inverter, disconnect input power, and discharge input  
capacitors according to instructions in Maintenance Section  
before touching any parts.  
Do not cut on coated metals, such as galvanized, lead, or cadmium  
plated steel, unless the coating is removed from the cutting area,  
the area is well ventilated, and if necessary, while wearing an air-  
supplied respirator. The coatings and any metals containing these  
elements can give off toxic fumes when cut.  
FLYING SPARKS can cause injury.  
Sparks and hot metal blow out from the cutting arc.  
Chipping and grinding cause flying metal.  
D
Do not cut containers with toxic or reactive materials inside or  
containers that have held toxic or reactive materials they must be  
emptied and properly cleaned first.  
D
Wear approved face shield or safety goggles with side shields.  
Wear proper body protection to protect skin.  
D
D
PLASMA ARC can cause injury.  
Wear flame-resistant ear plugs or ear muffs to prevent sparks from  
entering ears.  
The heat from the plasma arc can cause serious  
burns. The force of the arc adds greatly to the burn  
hazard. The intensely hot and powerful arc can  
quickly cut through gloves and tissue.  
ARC RAYS can burn eyes and skin.  
D
D
D
Keep away from the torch tip.  
Arc rays from the cutting process produce intense  
visible and invisible (ultraviolet and infrared) rays  
that can burn eyes and skin.  
Do not grip material near the cutting path.  
The pilot arc can cause burns keep away from torch tip when trig-  
ger is pressed.  
D
Wear face protection (helmet or shield) with correct shade of filter to  
protect your face and eyes when cutting or watching. ANSI Z49.1  
(see Safety Standards) suggests a No. 9 shade (with No. 8 as mini-  
mum) for all cutting currents less than 300 amperes. Z49.1 adds  
that lighter filter shades may be used when the arc is hidden by the  
workpiece. As this is normally the case with low current cutting, the  
shades suggested in Table 1 are provided for the operators conve-  
nience.  
D
D
D
D
Wear proper flame-retardant clothing covering all exposed body ar-  
eas.  
Point torch away from your body and toward work when pressing  
the torch trigger pilot arc comes on immediately.  
Turn off power source and disconnect input power before disas-  
sembling torch or changing torch parts.  
Use only torch(es) specified in the Owners Manual.  
D
D
D
Wear approved safety glasses with side shields under your helmet  
or shield.  
CYLINDERS can explode if damaged.  
Use protective screens or barriers to protect others from flash and  
glare; warn others not to watch the arc.  
Gas cylinders contain gas under high pressure. If  
damaged,a cylinder can explode. Since gas cylin-  
ders are normally part of metalworking processes,  
be sure to treat them carefully.  
Wear protective clothing made from durable, flame-resistant  
material(leather and wool) and foot protection.  
D
D
Protect compressed gas cylinders from excessive heat, mechani-  
cal shocks, slag, open flame, sparks, and arcs.  
Install and secure cylinders in an upright position by chaining them  
to a stationary support or equipment cylinder rack to prevent falling  
or tipping.  
Table 1. Eye Protection For Plasma Arc Cutting  
Current Level In Amperes  
Below 20  
Minimum Shade Number  
#4  
#5  
#6  
#8  
20 40  
40 60  
D
D
Keep cylinders away from any cutting or other electrical circuits.  
Never allow electrical contact between a plasma arc torch and a  
cylinder.  
60 80  
D
D
Never cut on a pressurized cylinder explosion will result.  
Use only correct gas cylinders, regulators, hoses, and fittings de-  
signed for the specific application; maintain them and associated  
parts in good condition.  
NOISE can damage hearing.  
Prolongednoise from some cutting applications can  
damage hearing if levels exceed limits specified by  
OSHA (see Safety Standards).  
D
D
Turn face away from valve outlet when opening cylinder valve.  
Keep protective cap in place over valve except when cylinder is in  
use or connected for use.  
D
D
Use approved ear plugs or ear muffs if noise level is high.  
Warn others nearby about noise hazard.  
D
Read and follow instructions on compressed gas cylinders, asso-  
ciated equipment, and CGA publication P-1 listed in Safety  
Standards.  
FUMES AND GASES can be hazardous.  
Cutting produces fumes and gases. Breathing  
these fumes and gases can be hazardous to  
your health.  
OM-217 Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Additional Symbols for Installation, Operation, and Maintenance  
HOT PARTS can cause severe burns.  
FIRE OR EXPLOSION hazard.  
D
D
Do not touch hot parts bare handed.  
D
D
Do not locate unit on, over, or near combustible  
surfaces.  
Allow cooling period before working on torch.  
Do not install unit near flammables.  
D
Do not overload building wiring be sure power supply system is  
properly sized, rated, and protected to handle this unit.  
MOVING PARTS can cause injury.  
D
D
Keep away from moving parts such as fans.  
STATIC (ESD) can damage PC boards.  
Keep all doors, panels, covers, and guards  
closed and securely in place.  
D
Put on grounded wrist strap BEFORE handling  
boards or parts.  
D
Use proper static-proof bags and boxes to  
store, move, or ship PC boards.  
FLYING METAL can injure eyes.  
D
Wear safety glasses with side shields or face  
shield.  
H.F. RADIATION can cause interference.  
D
High frequency (H.F.) can interfere with radio  
navigation, safety services, computers, and  
communicationsequipment.  
MAGNETIC FIELDS can affect pacemakers.  
D
Have only qualified persons familiar with elec-  
tronic equipment perform this installation.  
D
D
Pacemaker wearers keep away.  
Wearers should consult their doctor before go-  
ing near plasma arc cutting operations.  
D
D
The user is responsible for having a qualified electrician promptly  
correct any interference problem resulting from the installation.  
If notified by the FCC about interference, stop using the equipment  
at once.  
OVERUSE can cause OVERHEATING.  
D
D
Have the installation regularly checked and maintained.  
D
D
Allow cooling period; follow rated duty cycle.  
Keep high-frequency source doors and panels tightly shut, keep  
spark gaps at correct setting, and use grounding and shielding to  
minimize the possibility of interference.  
Reduce amperage (thickness) or reduce duty  
cycle before starting to cut again.  
ARC CUTTING can cause interference.  
EXPLODING HYDROGEN hazard.  
D
Electromagnetic energy can interfere with  
sensitive electronic equipment such as  
computers and computer-driven equipment  
such as robots.  
D
When cutting aluminum underwater or with the  
water touching the underside of the aluminum,  
free hydrogen gas may collect under the work-  
piece.  
D
D
D
D
To reduce possible interference, keep cables as short as possible,  
close together, and down low, such as on the floor.  
D
See your cutting engineer and water table instructions for help.  
Locate cutting operation 100 meters from any sensitive electronic  
equipment.  
FALLING UNIT can cause injury.  
Be sure this cutting power source is installed and grounded  
according to this manual.  
D
D
Use lifting eye to lift unit only, NOT running  
gear, gas cylinders, or any other accessories.  
If interference still occurs, the user must take extra measures such  
as moving the machine, using shielded cables, using line filters, or  
shielding the work area.  
Use equipment of adequate capacity to lift unit.  
D
If using lift forks to move unit, be sure forks are long enough to ex-  
tend beyond opposite side of unit.  
OM-217 Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-4. Principal Safety Standards  
Safety in Welding and Cutting, ANSI Standard Z49.1, from American  
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
from Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Standards, OSHA 29 CFR 1910, from Superinten-  
dent of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Code for Safety in Welding and Cutting, CSA Standard W117.2, from  
CanadianStandards Association, Standards Sales, 178 Rexdale Bou-  
levard, Rexdale, Ontario, Canada M9W 1R3.  
RecommendedPractices for Plasma Arc Cutting, American Welding  
Society Standard AWS C5.2, from American Welding Society, 550 N.W.  
LeJeune Rd, Miami, FL 33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, ANSI Standard Z87.1, from American National Standards Institute,  
1430 Broadway, New York, NY 10018.  
RecommendedSafe Practices for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, American  
Welding Society Standard AWS F4.1, from American Welding Society,  
550 N.W. LeJeune Rd, Miami, FL 33126  
Cutting And Welding Processes, NFPA Standard 51B, from National  
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.  
NationalElectrical Code, NFPA Standard 70, from National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
1-5. EMF Information  
Considerations About Welding Or Cutting And The Effects Of Low  
Frequency Electric And Magnetic Fields  
1. Keep cables close together by twisting or taping them.  
2. Arrange cables to one side and away from the operator.  
3. Do not coil or drape cables around your body.  
Welding or cutting current, as it flows through the welding or cutting  
cables, will cause electromagnetic fields. There has been and still is  
some concern about such fields. However, after examining more than  
500 studies spanning 17 years of research, a special blue ribbon  
committeeof the National Research Council concluded that: The body  
of evidence, in the committees judgment, has not demonstrated that  
exposure to power-frequency electric and magnetic fields is a human-  
health hazard.However, studies are still going forth and evidence  
continues to be examined. Until the final conclusions of the research are  
reached, you may wish to minimize your exposure to electromagnetic  
fields when welding or cutting.  
4. Keep cutting power source and cables as far away from operator  
as practical.  
5. Connect work clamp to workpiece as close to the cut as possi-  
ble.  
About Pacemakers:  
Pacemaker wearers consult your doctor first. If cleared by your doctor,  
then following the above procedures is recommended.  
To reduce magnetic fields in the workplace, use the following proce-  
dures:  
OM-217 Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 1 CONSIGNES DE SÉCURITÉ – LIRE AVANT  
UTILISATION  
pom_fre _nd_4/97  
1-1. Signification des symboles  
SignifieMise en garde ! Soyez vigilant ! Cette procédure  
présente des risques de danger ! Ceux-ci sont identifiés  
par des symboles adjacents aux directives.  
Y
Identifie un message de sécurité particulier.  
Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des ris-  
ques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN MOUVE-  
MENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles et aux directi-  
ves ci-dessous afin de connaître les mesures à prendre pour éviter tout dan-  
ger.  
. Signifie NOTA ; nest pas relatif à la sécurité.  
1-2. Dangers liés au coupage à larc au plasma  
Y
Les symboles présentés ci-après sont utilisés tout au long du  
présent manuel pour attirer votre attention et identifier les ris-  
ques de danger. Lorsque vous voyez un symbole, soyez  
vigilant et suivez les directives mentionnées afin d’éviter tout  
danger. Les consignes de sécurité présentées ci-après ne font  
que résumer linformation contenue dans les normes de sécu-  
rité énumérées à la section 1-5. Veuillez lire et respecter toutes  
ces normes de sécurité.  
UNE DÉCHARGE ÉLECTRIQUE peut  
entraîner la mort.  
Le fait de toucher à une pièce électrique sous tension peut  
donner une décharge fatale ou entraîner des brûlures  
graves. Le chalumeau et le circuit de masse sont  
automatiquementactifs lorsque le poste est sous tension.  
Lalimentation dentrée et les circuits internes de lappareil le sont également.  
Le coupage au plasma darc exige des tensions plus élevées que le soudage  
pour amorcer et maintenir larc (souvent de 200 à 400 V CC), cest pourquoi on  
fait appel à des chalumeaux conçus avec un système de verrouillage  
sécuritaire qui met lappareil hors tension lorsque la capsule antifeu est  
desserrée ou si le tube touche l’électrode à lintérieur de la buse. Un poste  
incorrectement installé ou inadéquatement mis à la terre constitue un danger.  
Y
Y
Linstallation, lutilisation, lentretien et les réparations ne  
doivent être confiés qu’à des personnes qualifiées.  
Au cours de lutilisation, tenir toute personne à l’écart et plus  
particulièrement les enfants.  
D
D
Ne touchez pas aux pièces électriques sous tension.  
Portez des gants isolants et des vêtements de protection secs et sans  
LE COUPAGE présente un risque de  
trous.  
feu ou dexplosion.  
D
Isolezvous de la pièce à couper et du sol en utilisant des housses ou des  
tapis assez grands afin d’éviter tout contact physique avec la pièce à cou-  
per ou le sol.  
Ne touchez pas aux pièces du chalumeau si vous êtes en contact avec la  
pièce à couper ou le sol.  
Des particules de métal chaud et des étincelles peuvent  
jaillir de la pièce au moment du coupage. Les étincelles et le  
métal chaud, la pièce à couper chauffée et l’équipement  
chaud peuvcnt causer un feu ou des brûlures. Avant de  
D
D
D
Mettez lappareil hors tension avant deffectuer la vérification, le nettoyage  
ou le changement dune pièce du chalumeau.  
commencer à travailler, assurezvous que lendroit est sécuritaire.  
D
Protégezvous, ainsi que toute autre personne travaillant sur les lieux,  
contre les étincelles et le métal chaud.  
Ne coupez pas dans un endroit où des étincelles pourraient atteindre des  
matières inflammables.  
Déplacez toute matière inflammable se trouvant à lintérieur dun périmètre  
de 10,7 m (35 pi) de la pièce à couper. Si cela est impossible, vous devez  
les couvrir avec des housses approuvées et bien ajustées.  
Assurezvous quaucune étincelle ni particule de métal ne peut se glisser  
dans de petites fissures ou tomber dans dautres pièces.  
Afin d’éliminer tout risque de feu, soyez vigilant et gardez toujours un extinc-  
teur à la portée de la main.  
Si vous coupez sur un plafond, un plancher ou une cloison, soyez conscient  
que cela peut entraîner un feu de lautre côté.  
Coupez lalimentation dentrée avant dinstaller lappareil ou deffectuer  
lentretien. Verrouillez ou étiquetez la sortie dalimentation selon la norme  
OSHA 29 CFR 1910.147 (reportezvous aux Principales normes de sécu-  
rité).  
Installez le poste correctement et mettezle à la terre convenablement se-  
lon les consignes du manuel de lopérateur et les normes nationales,  
provinciales et locales.  
Assurezvous que le fil de terre du cordon dalimentation est correctement  
relié à la borne de terre dans la boîte de coupure ou que la fiche du cordon  
est branchée à une prise correctement mise à la terre vous devez tou-  
jours vérifier la mise à la terre.  
Avant deffectuer les connexions dalimentation, vous devez relier le bon fil  
de terre.  
Vérifiez fréquemment le cordon dalimentation afin de vous assurer quil  
nest pas altéré ou à nu, remplacezle immédiatement sil lest. Un fil à nu  
peut entraîner la mort.  
D
D
D
D
D
D
D
D
D
D
D
Ne coupez pas sur un contenant fermé tel quun réservoir ou un bidon.  
Fixez le câble de masse sur la pièce à couper, le plus près possible de la  
zone à couper afin de prévenir que le courant de coupage ne prenne une  
trajectoire inconnue ou longue et ne cause ainsi une décharge électrique ou  
un feu.  
D
D
L’équipement doit être hors tension lorsquil nest pas utilisé.  
Vérifiez et remplacez les cosses du câble du chalumeau si elles sont usées  
ou altérées.  
D
D
Ne coupez jamais des contenants qui peuvent contenir des matières inflam-  
mables. Vous devez en premier lieu les vider et les nettoyer  
convenablement.  
Ne coupez pas dans un endroit où latmosphère risque de contenir de la  
poussière ou des vapeurs explosives.  
D
D
D
Le câble du chalumeau ne doit pas senrouler autour de votre corps.  
Si les normes le stipulent, la pièce à couper doit être mise à la terre.  
Utilisez uniquement de l’équipement en bonne condition. Réparez ou rem-  
placez immédiatement toute pièce altérée.  
D
D
D
Ne coupez pas de bouteilles, de tuyaux ou de contenants pressurisés.  
Ne coupez pas de contenants qui ont déjà reçu des combustibles.  
Portez des vêtements de protection exempts dhuile tels que des gants en  
cuir, une veste résistante, des pantalons sans revers, des bottes et un cas-  
que.  
Ne placez pas le poste sur une surface combustible ou audessus de celle–  
ci.  
Avant le coupage, retirez tout combustible de vos poches, par exemple un  
briquet au butane ou des allumettes.  
D
D
Portez un harnais de sécurité si vous devez travailler audessus du sol.  
Assurezvous que tous les panneaux et couvercles sont correctement en  
place.  
Nessayez pas daller à lencontre des systèmes de verrrouillage de sécuri-  
té ou de les contourner.  
Utilisez uniquement le ou les chalumeaux recommandés dans le manuel  
de lopérateur.  
D
D
D
D
OM-217 Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D
D
Napprochez pas le tube du chalumeau et larc pilote lorsque la gâchette est  
enfoncée.  
Le câble de masse doit être pincé correctement sur la pièce à couper, métal  
contre métal (et non de telle sorte quil puisse se détacher), ou sur la table  
de travail le plus près possible de la ligne de coupage.  
D
D
Ne mettez pas votre tête audessus des vapeurs. Ne respirez pas ces va-  
peurs.  
Si vous êtes à lintérieur au moment du coupage, ventilez la pièce ou ayez  
recours à une ventilation aspirante installée près de larc pour évacuer les  
vapeurs et les gaz.  
D
D
Si la ventilation est médiocre, utilisez un respirateur antivapeurs  
approuvé.  
D
Isoler la pince de masse quand pas mis à la pièce pour éviter le contact  
avec tout objet métallique.  
Veuillez lire le Material Safety Data Sheets (MSDS) et les instructions du  
fabricant pour obtenir plus de renseignements sur les métaux à couper, les  
enrobages et les nettoyants.  
Travaillez dans un espace restreint uniquement sil est bien ventilé ou si  
vous portez un respirateur antivapeurs. Les vapeurs causées par le cou-  
page et l’épuisement de loxygène peuvent altérer la qualité de lair et  
entraîner des blessures ou la mort. Assurezvous que lair ambiant est sain  
pour la santé.  
Il y a DU COURANT CONTINU IMPORTANT dans  
les convertisseurs après la suppression de lali-  
mentation électrique.  
D
D
Arrêter les convertisseurs, débrancher le courant électrique, et décharger  
les condensateurs dalimentation selon les instructions indiquées dans la  
partie entretien avant de toucher les pièces.  
D
D
Ne coupez pas dans un endroit près dopérations de décapage, de net-  
toyage ou de vaporisation. La chaleur et les rayons darc peuvent réagir  
avec les vapeurs et former des gaz hautement toxiques et irritants.  
Ne coupez pas des métaux enrobés tels que des métaux galvanisés,  
contenant du plomb ou de lacier plaqué au cadmium, à moins que lenroba-  
ge ne soit ôté de la surface du métal à couper, que lendroit où vous  
travaillez ne soit bien ventilé, ou, si nécessaire, que vous ne portiez un res-  
pirateur antivapeurs. Les enrobages ou tous métaux qui contiennent ces  
éléments peuvent créer des vapeurs toxiques sils sont coupés.  
LES ÉTINCELLES VOLANTES ris-  
quent de provoquer des blessures.  
Le coupage plasma produit des étincelles et projections de  
métal à très haute température. Lorsque la pièce refroidit,  
du laitier peut se former.  
D
Portez une visière ou des lunettes de sécurité avec des écrans latéraux ap-  
prouvées.  
D
Ne coupez pas de contenants qui renferment ou ont renfermés des matiè-  
res toxiques ou réactives vous devez en premier lieu les vider et les  
nettoyer convenablement.  
D
D
Portez des vêtements de protection adéquats afin de protéger votre peau.  
Ayez recours à des protègetympans ou à un serretête ignifuges afin  
d’éviter que les étincelles nentrent dans vos oreilles.  
LE PLASMA DARC peut entraîner  
des blessures.  
LES RAYONS DARC peuvent en-  
traîner des brûlures aux yeux et à la  
peau.  
La chaleur dégagée par le plasma darc peut entraîner de  
sérieuses brûlures. La force de larc est un facteur qui  
sajoute au danger de brûlures. La chaleur intense et la  
puissance de larc peuvent rapidement passer au travers  
de gants et de tissus.  
Les rayons darc provenant du procédé de coupage  
produisent des rayons visibles et invisibles intenses  
(ultraviolets et infrarouges) qui peuvent entraîner des brûlures aux yeux et à la  
peau.  
D
D
D
Napprochez pas le tube du chalumeau.  
Ne saisissez pas la pièce à couper près de la ligne de coupage.  
Larc pilote peut causer des brûlures napprochez pas le tube du chalu-  
meau lorsque vous avez appuyé sur le gâchette.  
D
Lorsque vous coupez ou regardez quelquun couper, portez un masque ou  
un écran facial avec le filtre approprié. La norme ANSI Z49.1 (reportez–  
vous aux Principales normes de sécurité) suggère dutiliser un filtre de  
teinte nd 9 (nd 8 étant le minimum) pour tout travail de coupage faisant ap-  
pel à un courant de moins de 300 A. On mentionne également dans la  
norme Z49.1 quun filtre plus faible peut être utilisé lorsque larc est caché  
par la pièce à couper. Comme cela est habituellement le cas pour les tra-  
vaux de coupage à faible courant, les teintes énumérées au tableau 1 sont  
fournies à titre dinformation pour lopérateur.  
D
D
Portez des vêtements de protection adéquats qui recouvrent tout votre  
corps.  
Ne pointez pas le chalumeau en direction de votre corps ni de la pièce à  
couper lorsque vous appuyez sur la gâchette larc pilote sallume automa-  
tiquement.  
Mettez lalimentation hors tension et débranchez le cordon dalimentation  
avant de démonter le chalumeau ou de changer une pièce du chalumeau.  
D
D
D
D
Porter des lunettes de sécurité à coques latérales sous votre casque ou  
écran facial.  
Utilisez uniquement le ou les chalumeaux recommandés dans le manuel  
Ayez recours à des écrans protecteurs ou à des rideaux pour protéger les  
autres contre les rayonnements et les éblouissements; prévenez toute  
personne sur les lieux de ne pas regarder larc.  
de lopérateur.  
D
Portez des vêtements confectionnés avec des matières résistantes et igni-  
fuges (cuir et laine) et des bottes de protection.  
LES BOUTEILLES peuvent exploser  
si elles sont endommagées.  
Les bouteilles de gaz contiennent du gaz sous haute  
pression. Si une bouteille est endommagée, elle peut  
exploser. Puisque les bouteilles de gaz font habituellement  
partie dun processus de travail des métaux, assurezvous  
de les manipuler correctement.  
Tableau 1. Protection des yeux pour le coupage au plasma darc  
Intensité de courant en ampères  
Filtre de teinte (minimum)  
Moins de 20  
20 40  
40 60  
no. 4  
no. 5  
no. 6  
no. 8  
D
D
Protégez les bouteilles de gaz comprimé contre la chaleur excessive, les  
chocs mécaniques, le laitier, la flamme, les étincelles et larc.  
Installez et attachez les bouteilles dans la position verticale à laide dune  
chaîne, sur un support stationnaire ou un châssis portebouteille afin de  
prévenir quelles ne tombent ou ne basculent.  
60 80  
D
D
D
D
Les bouteilles ne doivent pas être près de la zone de coupage ni de tout  
autre circuit électrique.  
Un contact électrique ne doit jamais se produire entre un chalumeau de  
plasma darc et une bouteille.  
Ne coupez jamais sur une bouteille pressurisée une explosion en  
résulterait.  
Utilisez uniquement des bouteilles de gaz, des détendeurs, des boyaux et  
des raccords conçus pour lapplication déterminée. Gardezles, ainsi que  
toute autre pièce associée, en bonne condition.  
LE BRUIT peut endommager louïe.  
Certaines applications de coupage produisent un bruit  
constant, ce qui peut endommager louïe si le niveau  
sonore dépasse les limites permises par lOSHA (repor-  
tezvous aux Principales normes de sécurité).  
D
D
Utilisez des protègetympans ou un serretête antibruit si le niveau sonore  
est élevé.  
Prévenez toute personne sur les lieux du danger relié au bruit.  
D
D
D
Détournez votre visage du détendeurrégulateur lorsque vous ouvrez la  
soupape de la bouteille.  
Le couvercle du détendeur doit toujours être en place, sauf lorsque vous  
utilisez la bouteille ou quelle est reliée pour usage ultérieur.  
Lisez et suivez les instructions sur les bouteilles de gaz comprimé, l’équi-  
pement connexe et le dépliant P1 de la CGA mentionné dans les  
Principales normes de sécurité.  
LES FUMÉES ET LES GAZ peuvent  
être dangereux.  
Le coupage produit des vapeurs et des gaz. Respirer  
ces vapeurs et ces gaz peut être dangereux pour la  
santé.  
OM-217 Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-3. Dangers supplémentaires en relation avec linstallation, le fonctionnement  
et la maintenance  
DES PIECES CHAUDES peuvent pro-  
voquer des brûlures graves.  
Risque DINCENDIE OU  
DEXPLOSION.  
D
D
Ne pas toucher des parties chaudes à mains nues.  
D
D
Ne pas placer lappareil sur, au-dessus ou à proximité  
de surfaces infllammables.  
Laisser refroidir avant dintervenir sur la torche.  
Ne pas installer lappareil à proximité de produits in-  
flammables  
DES ORGANES MOBILES peuvent  
provoquer des blessures.  
D
Ne pas surcharger linstallation électrique sassurer que lalimentation est  
correctement dimensionné et protégé avant de mettre lappareil en service.  
D
D
Sabstenir de toucher des organes mobiles tels que  
des ventilateurs.  
LES CHARGES ÉLECTROSTATI-  
QUES peuvent endommager les cir-  
cuits imprimés.  
Maintenir fermés et verrouillés les portes, panneaux,  
recouvrements et dispositifs de protection.  
D
D
Etablir la connexion avec la barrette de terre avant de  
manipuler des cartes ou des pièces.  
DES PARTICULES VOLANTES  
peuvent blesser les yeux.  
Utiliser des pochettes et des boîtes antistatiques  
pour stocker, déplacer ou expédier des cartes PC.  
D
Porter des lunettes de sécurité avec protections laté-  
rales ou frontales.  
LE RAYONNEMENT HAUTE FRÉ-  
QUENCE (H.F.) risque de provoquer  
des interférences.  
LES CHAMPS MAGNÉTIQUES peuv-  
ent affecter les stimulateurs cardia-  
ques.  
D
Le Rayonnement haute frequence (H.F.) peut provo-  
quer des interférences avec les équipements de ra-  
dionavigation et de communication, les services de  
sécurité et les ordinateurs.  
D
D
Porteurs de stimulateur cardiaque, restez à distance.  
Les porteurs sont priés de consulter leur médecin  
avant dapprocher les opérations de coupage  
plasma.  
D
D
Demander seulement à des personnes qualifiées familiarisées avec des  
équipements électroniques de faire fonctionner linstallation.  
Lutilisateur est tenu de faire corriger rapidement par un électricien qualifié  
les interférences résultant de linstallation.  
Si le FCC signale des interférences, arrêter immédiatement lappareil.  
Effectuer régulièrement le contrôle et lentretien de linstallation.  
Maintenir soigneusement fermés les portes et les panneaux des sources  
de haute fréquence, maintenir les éclateurs à une distance correcte et utili-  
ser une terre et et un blindage pour réduire les interférences éventuelles.  
LEMPLOI EXCESSIF peut  
SURCHAUFFER L’ÉQUIPEMENT.  
D
D
D
D
D
Prévoir une période de refroidissement; respecter le  
cycle opératoire nominal.  
Réduire lampérage (épaisseur) avant de continuer à  
couper ou réduire le facteur de marche.  
LE COUPAGE Ã LARC peut causer  
des interférence.  
Danger  
DROGÈNE.  
DEXPLOSION  
DHY-  
D
L’énergie électromagnétique peut gêner le fonction-  
nement dappareils électroniques comme des ordi-  
nateurs et des robots.  
D
D
Lors du coupage daluminium partiellement ou totale-  
ment immergé dans leau, de lhydrogène libre peut  
saccumuler sous la pièce.  
D
Pour réduire la possibilité dinterférence, maintenir les câbles aussi courts  
que possible, les grouper, et les poser aussi bas que possible (ex. par  
terre).  
Consultez votre ingénieur de coupage et les instruc-  
D
D
D
Veiller à couper à une distance de 100 mètres de tout équipement électroni-  
tions de la table de coupage.  
que sensible.  
Sassurer que la source de coupage est correctement branchée et mise à  
LA CHUTE DE LAPPAREIL peut  
blesser.  
la terre.  
Si linterférence persiste, lutilisateur doit prendre des mesures supplémen-  
taires comme écarter la machine, utiliser des câbles blindés de des filtres,  
ou boucler la zone de travail.  
D
D
Utiliser lanneau de levage uniquement pour soulever  
lappareil, NON PAS les chariot, les bouteilles de gaz  
ou tout autre accessoire.  
Utiliser un engin dune capacité appropriée pour sou-  
lever lappareil.  
D
En utilisant des fourches de levage pour déplacer lunité, sassurer que  
les fourches sont suffisamment longues pour dépasser du côté opposé  
de lappareil.  
1-4. Principales normes de sécurité  
Safety in Welding and Cutting, norme ANSI Z49.1, de lAmerican Wel-  
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126  
Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,  
de la Compressed Gas Association, 1235 Jefferson Davis Highway,  
Suite 501, Arlington, VA 22202.  
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent  
of Documents, U.S. Government Printing Office, Washington, D.C.  
20402.  
Règles de sécurité en soudage, coupage et procédés connexes, norme  
CSA W117.2, de lAssociation canadienne de normalisation, vente de  
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.  
RecommendedSafe Practice for the Preparation for Welding and Cut-  
ting of Containers That Have Held Hazardous Substances, norme AWS  
F4.1, de lAmerican Welding Society, 550 N.W. Lejeune Rd, Miami FL  
33126  
Safe Practices For Occupation And Educational Eye And Face Protec-  
tion, norme ANSI Z87.1, de lAmerican National Standards Institute,  
1430 Broadway, New York, NY 10018.  
NationalElectrical Code, NFPA Standard 70, de la National Fire Protec-  
tion Association, Batterymarch Park, Quincy, MA 02269.  
Cutting and Welding Processes, norme NFPA 51B, de la National Fire  
Protection Association, Batterymarch Park, Quincy, MA 02269.  
OM-217 Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1-5. Information sur les champs électromagnétiques  
Données sur le soudage électrique et sur les effets, pour lorganisme,  
des champs magnétiques basse fréquence  
Afin de réduire les champs électromagnétiques dans lenvironnement  
de travail, respecter les consignes suivantes :  
1
Garder les câbles ensembles en les torsadant ou en les  
attachant avec du ruban adhésif.  
Lextrait suivant est tiré des conclusions générales du document intitulé  
Biological Effects of Power Frequency Electric & Magnetic Fields –  
Background Paper, OTABPE53 (Washington DC : U.S. Govern-  
ment Printing Office, mai 1989), publié par le Office of Technology  
Assessment du Congrès américain : «... il existe maintenant dabon-  
dantes données scientifiques compilées à la suite dexpériences sur la  
cellule ou d’études sur des animaux et des humains, qui montrent clai-  
rement que les champs électromagnétiques basse fréquence peuvent  
avoir des effets sur lorganisme et même y produire des transforma-  
tions. Même sil sagit de travaux de très grande qualité, les résultats  
sont complexes. Cette démarche scientifique ne nous permet pas  
d’établirun tableau densemble cohérent. Pire encore, elle ne nous per-  
met pas de tirer des conclusions finales concernant les risques  
éventuels, ni doffrir des conseils sur les mesures à prendre pour rédui-  
re sinon éliminer les risques éventuels». (Traduction libre)  
2
3
Mettre tous les câbles du côté opposé de lopérateur.  
Ne pas courber pas et ne pas entourer pas les câbles autour de  
vous.  
4
5
Garder le poste de soudage et les câbles le plus loin possible de  
vous.  
Relier la pince de masse le plus près possible de la zone de  
soudure.  
Consignes relatives aux stimulateurs cardiaques :  
Les consignes mentionnées précédemment font partie de celles desti-  
nées aux personnes ayant recours à un stimulateur cardiaque. Veuillez  
consulter votre médecin pour obtenir plus de détails.  
OM-217 Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 2 DEFINITIONS  
2-1. Warning Label Definitions  
Warning! Watch Out! There are  
possible hazards as shown by the  
symbols.  
1
Cutting sparks can cause  
explosion or fire.  
1.1 Keep flammables away from  
cutting. Do not cut near  
flammables.  
1.2 Cutting sparks can cause  
fires. Have a fire extinguisher  
nearby, and have a  
1
2
3
4
5
6
1.1  
2.1  
3.1  
4.1  
5.1  
1.2  
1.3  
watchperson ready to use it.  
1.3 Do not cut on drums or any  
closed containers.  
2
The plasma arc can cause  
injury and burns.  
2.1 Turn off power before  
disassembling torch.  
2.2  
2.3  
2.2 Do not grip material near  
cutting path.  
2.3 Wear complete body  
protection.  
3
Electric shock from torch or  
wiring can kill.  
3.1 Wear dry insulating gloves.  
Do not wear wet or damaged  
gloves.  
3.2  
3.3  
3.2 Protect yourself from electric  
shock by insulating yourself  
from work and ground.  
3.3 Disconnect input plug or  
power before working on  
machine.  
4.2  
4.3  
4
Breathing cutting fumes can  
be hazardous to your health.  
4.1 Keep your head out of the  
fumes.  
4.2 Use forced ventilation or local  
exhaust to remove the fumes.  
4.3 Use ventilating fan to remove  
fumes.  
5
Arc rays can burn eyes and  
injure skin.  
+
+ +  
5.1 Wear hat and safety glasses.  
Use ear protection and button  
shirt collar. Use welding  
helmet with correct shade of  
filter. Wear complete body  
protection.  
7
6
Become trained and read the  
instructions before working on  
the machine or cutting.  
+
7
Do not remove or paint over  
(cover) the label.  
S-179 219  
1/96  
OM-217 Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning! Watch Out! There are  
possible hazards as shown by the  
symbols.  
Electric shock from wiring can kill.  
Disconnect input plug or power  
before working on machine.  
Read the Owners Manual before  
working on this machine.  
1
Consult rating label for input  
power requirements, and  
check power available at the  
job site they must match.  
2
3
4
5
Read Owners Manual and  
inside labels for connection  
points and procedures.  
Move jumper links as shown  
on inside label to match  
voltage at job site.  
?
V
1
2
3
Having a loop of extra length,  
connect grounding conductor  
first.  
Connect line input conductors  
as shown on inside label –  
double-check all connections,  
jumper link positions, and  
input voltage before applying  
power.  
?
?
V
A
5
3
4
S-179 290  
1/96  
1
2
3
Input connection point for  
nitrogen gas.  
2
3
Input connection point for  
compressed air.  
Air/gas pressure adjustment  
control with recommended  
setting.  
+
N
70 psi  
4.8 bar  
( )  
483 kPa  
S-175 971  
1
1/96  
OM-217 Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-2. Manufacturers Rating Label For CE Products  
Match label to one on  
unit. See Section 3-4.  
100 Ampere Model  
70 Ampere Model  
3
3
EN 60974-1  
EN 60974-1  
30A/120V  
100A/120V  
30A/120V  
X
70A/120V  
100%  
X
80%  
100A  
120V  
100%  
80A  
I
2
I
2
70A  
U = 270V  
0
U = 270V  
0
U
2
120V  
U
2
120V  
U
1
V
I
1
U
1
V
I
1
3
3
220V  
380V  
78A  
45A  
64A  
37A  
220V  
380V  
415V  
57A  
33A  
30A  
415V  
41A  
34A  
50 Hz  
50 Hz  
IP 21S  
IP 21S  
S-174 462-A  
S-174 463-A  
OM-217 Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2-3. Symbols And Definitions  
Some symbols are found only on CE products.  
NOTE  
Plasma Arc Cutting  
(PAC)  
Amperes  
Volts  
Trigger Hold On  
Trigger Hold Off  
Pulse  
A
V
Continuous Pilot  
Arc  
Pilot/Pulse Starting  
Increase  
No Do Not Do  
Output  
Temperature  
Input  
This  
Protective Earth  
(Ground)  
Three Phase  
High Frequency  
Percent  
On  
Off  
Direct Current  
Rated No Load  
Voltage (Average)  
Conventional Load  
Voltage  
Primary Voltage  
Line Connection  
U0  
I1  
U1  
I2  
U2  
X
Three Phase  
Transformer  
Rectifier  
Rated Welding  
Current  
Primary Current  
Duty Cycle  
Degree Of  
Protection  
Torch-Tip-To  
Electrode Short  
Loose Shield Cup  
Work  
Hertz  
Hz  
IP  
Air/Gas Pressure  
Adjustment  
Low Air Pressure  
Light  
Nitrogen Gas Input  
Connection  
Adjust Air/Gas  
Pressure  
SECTION 3 INSTALLATION  
3-1. Specifications  
Plasma  
Gas  
Flow/  
Amperes Input at Rated Output,  
50 or 60 Hz, Three-Phase  
Model/  
Rated  
Output  
Plasma  
Gas  
Max  
IP  
200 V 220 V 230 V 380 V 415 V 460 V 575 V  
KVA  
KW  
Pressure  
OCV Rating  
1000 / 70  
Amperes At  
108 Volts DC  
At 100%  
57  
(4.0*)  
54  
(2.6*)  
33  
(2.5*)  
30  
(1.5*)  
27  
(1.3*)  
22  
21  
10  
– –  
(1.0*) (1.04*) (0.6*)  
7 CFM  
(198 L/min)  
At 70 PSI  
(482 kPa)  
Air Or  
Nitrogen  
Only  
270  
Volts  
DC  
Duty Cycle  
21S  
1250 / 100  
Amperes At  
120 Volts DC  
At 80% Duty  
Cycle  
85  
(3.4*)  
77  
(4.0*)  
74  
(2.9*)  
45  
(2.5*)  
41  
(1.5*)  
37  
(1.5*)  
30  
(1.0*)  
30  
(1.2*)  
16  
(0.5*)  
*While idling  
OM-217 Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-2. Duty Cycle And Overheating  
Duty Cycle is percentage of 10 min-  
utes that unit can cut at rated load  
without overheating.  
70 Ampere Models: 100% Duty Cycle At 70 Amperes  
If unit overheats, thermostat(s)  
opens, output stops, Temperature  
trouble light goes On, and cooling  
fan runs. Wait fifteen minutes for  
unit to cool or temperature light to  
go off. Reduce amperage or duty  
cycle before cutting or gouging.  
Continuous Welding  
Y
Exceeding duty cycle can  
damage unit and void  
warranty.  
100 Ampere Models: 80% Duty Cycle At 100 Amperes  
8 Minutes Welding  
2 Minutes Resting  
Overheating  
A
0
15  
OR  
Minutes  
Reduce Duty Cycle  
duty1 4/95 Ref. ST-159 463-B  
3-3. Cutting Speed  
The cutting speed curves show the  
recommended maximum cutting  
speed capabilities of the power  
source and torch for mild steel of  
various thickness.  
Cut at speeds below the lines  
shown to avoid poor cuts and torch  
wear.  
70 Ampere Model  
100 Ampere Model  
ST-171 819 / ST-171 820  
OM-217 Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-4. Selecting A Location  
1
Lift Hook  
Install lift hooks using supplied  
bolts. Tighten to 25 ft/lb (34 N·m).  
2
3
Spreader Bar (Not Supplied)  
Lifting Cable (Not Supplied)  
Movement  
If lifting unit, use spreader and  
cable.  
3
2
4
5
Lifting Eye  
Lifting Forks  
If using lifting forks, extend forks  
beyond opposite side of unit.  
1
4
6
Rating Label (Non CE Models  
Only)  
7
Rating Label (CE Models  
Only, See Section 2-2)  
Use rating label to determine input  
power needs.  
OR  
5
8
9
Plate Label (CE Models Only)  
Line Disconnect Device  
Locate unit near correct input pow-  
er supply.  
Y
Special installation may be  
required where gasoline or  
volatile liquids are present –  
see NEC Article 511 or CEC  
Section 20.  
Location And Airflow  
6
9
8
7
18 in (460  
mm)  
18 in (460  
mm)  
S-0439 / Ref. ST-800 402-B / ST-159 463-B  
OM-217 Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-5. Dimensions And Weight  
Dimensions  
Height  
37-1/4 in (946 mm)  
A
B
Width  
22-3/4 in (578 mm)  
20 in (508 mm)  
Length  
C
A
B
C
D
E
F
22-1/16 in (560 mm)  
21-1/32 in (210 mm)  
1-1/32 in (26 mm)  
18-13/16 in (478 mm)  
17-11/16 (449 mm)  
5-5/8 (143 mm)  
D
E
F
G
H
1-1/8 (29 mm)  
Bottom Front  
7/16 in (11 mm) Dia  
Weight  
H
ST-159 464-B  
G
405 lbs (184 kg)  
3-6. Tipping  
Y
Be careful when placing or  
moving unit over uneven  
surfaces.  
OM-217 Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-7. Connecting Work Clamp And Gas/Air Supply  
1
Work Cable  
Connect work cable to supplied  
clamp as shown.  
Connect work clamp to a clean lo-  
cation on workpiece, as close to  
cutting area as possible.  
. Use only clean, dry air or nitro-  
gen gas. Do not use any other  
gas or combination of gases.  
1
2
3
4
5
Air Filter/Regulator  
Gas/Air Inlet Opening  
Hose  
Teflon Tape  
Obtain hose with 5/8-18 right-hand  
thread fitting. Wrap threads with  
teflon tape, and install fitting in  
opening.  
From Gas/Air Supply  
Adjust gas/air pressure according  
to Section 4-1.  
2
4
3
5
Tools Needed:  
5/8, 1-1/8 in  
ST-800 958 / ST-800 701 / S-0818  
OM-217 Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-8. Remote Control Connections  
Y
Turn Off power before instal-  
ling remote control.  
Remove left side panel.  
1
2
Terminal Strip 1T  
Connection Label  
. Lead colors shown match  
those of Remote Pendant Con-  
trol supplied with machine-held  
torches.  
Route leads through hole below  
torch and work cable access holes.  
Refer to connection label and make  
connections as follows:  
Torch On/Off Connections:  
3
Remote On/Off Switch  
Connect switch leads to terminals 3  
and 4 as shown. Switch closure  
starts cutting arc.  
Output Control Connections:  
2
1
4
Jumper Link  
For remote output control, remove  
jumper link between terminals 9  
and 10, and reinstall between termi-  
nals 8 and 9 as shown. This dis-  
ables front panel Output Control  
and enables remote output control.  
1T  
5
Remote Output Control  
1
71  
Connect control leads to terminals  
7, 8, and 11 as shown.  
2
3
72  
84  
85  
64  
63  
65  
Output Sensor Connections:  
Black  
6
Output Sensor Terminals  
White  
Torch  
Switch  
Terminals 5 and 6 connect to inter-  
nal, normally-open contacts which  
close when cutting output is pres-  
ent. For example, use signal to start  
automatic fixture.  
4
N.O.  
Output  
Sensor  
5
6
Reinstall side panel.  
6
5
Command  
Ref.  
+10 Volts DC  
(Brown)  
4
7
Remote  
8
3
Wiper (Red)  
Jumper  
Common  
9
66  
70  
43  
10  
11  
Panel  
Signal  
Ground  
GND (Green)  
S-169 259  
Tools Needed:  
3/8 in  
Ref. ST-159 466-C / Ref. ST-150 802-A  
OM-217 Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-9. Electrical Service Guide  
60 Hertz Models  
Input Voltage  
70 Ampere Model  
100 Ampere Model  
230  
460  
27  
575  
200  
85  
230  
74  
460  
37  
575  
30  
54  
80  
6
22  
30  
10  
Input Amperes At Rated Output  
Max Recommended Standard Fuse Or Circuit  
Breaker Rating In Amperes  
40  
10  
125  
4
125  
4
60  
8
45  
10  
Min Input Conductor Size In AWG/Kcmil  
226  
(69)  
418  
(127)  
653  
(199)  
160  
(49)  
212  
(65)  
389  
(119)  
413  
(126)  
Max Recommended Input Conductor Length In  
Feet (Meters)  
8
10  
10  
6
6
10  
10  
Min Grounding Conductor Size In AWG/Kcmil  
Reference: 1993 National Electrical Code (NEC)  
S-0092-J  
50 Hertz Models  
Input Voltage  
70 Ampere Model  
100 Ampere Model  
220  
380  
33  
415  
220  
380  
45  
415  
57  
80  
6
30  
45  
10  
77  
125  
4
41  
60  
8
Input Amperes At Rated Output  
Max Recommended Standard Fuse Or Circuit Breaker  
Rating In Amperes  
50  
8
70  
8
Min Input Conductor Size In AWG/Kcmil  
187  
(57)  
375  
(114)  
304  
(93)  
190  
(58)  
260  
(79)  
310  
(94)  
Max Recommended Input Conductor Length In Feet  
(Meters)  
8
10  
10  
6
8
10  
Min Grounding Conductor Size In AWG/Kcmil  
Reference: 1993 National Electrical Code (NEC)  
S-0092-J  
OM-217 Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3-10. Placing Jumper Links And Connecting Input Power  
2
220 VOLTS  
380 VOLTS  
415 VOLTS  
L1 L2 L3  
L1 L2 L3  
L1 L2 L3  
S-151 770  
200 VOLTS  
230 VOLTS  
460 VOLTS  
L1  
L2  
L3  
L1  
L2  
L3  
L1  
L2  
L3  
S-031 770-A  
230 VOLTS  
460 VOLTS  
575 VOLTS  
L1  
L2  
L3  
L1  
L2  
L3  
L1  
L2  
L3  
S-012 242-A  
1
GND/PE  
Earth Ground  
Check input voltage available at  
site.  
1
1
Jumper Link Label  
Check label only one is on unit.  
Jumper Links  
Connect GND/PE  
Conductor First  
2
Move jumper links to match input  
voltage.  
L1 (U) L2 (V)  
Connect GND/PE  
Conductor First  
L3 (W)  
3
Input And Grounding  
Conductors  
Select size and length using Sec-  
tion 3-9.  
4
4
Line Disconnect Device  
Select type and size of overcurrent  
protection using Section 3-9.  
Reinstall side panel.  
Y
Special installation may be  
required where gasoline or  
volatile liquids are present –  
see NEC Article 511 or CEC  
Section 20.  
L3 (W)  
L2 (V)  
L1 (U)  
3
Tools Needed:  
3/8, 7/12, 1/2 in  
Ref. ST-800 718  
OM-217 Page 19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 4 OPERATION  
4-1. Controls  
8
7
6
5
4
3
2
1
Setting Gas/Air Pressure  
10  
Set To 70 psi  
(482 kPa)  
4
9
Requires  
80-150 psi  
(552-1034 kPa)  
Supply  
1
2
3
Pilot Light  
Ready light comes on when Power switch is Place switch down for pulsed pilot arc  
placed in On position, indicating that all safe- output. Use this position whenever possible  
Power Switch  
Output Control  
ty shutdown systems are okay.  
to reduce wear on torch and consumables.  
If Ready light does not come on, check  
Trouble Lights.  
Place switch up for a continuous pilot arc.  
Use this position when cutting starts are  
critical or while cutting expanded metals.  
Use control to set cutting output.  
For non-shielded cutting, use a 1/8 in (3 mm)  
standoff distance between torch tip and  
workpiece.  
6
7
Trouble Lights (See Section 5-3)  
Trigger Hold Switch  
Setting Gas/Air Pressure  
To cut without holding torch trigger, place  
switch up, and begin cutting by pressing and  
releasing torch trigger. To stop cutting, press  
and release trigger.  
9
Air Filter/Regulator  
4
Set/Run Switch  
Place switch up to safely adjust gas/air pres-  
sure. Only gas/air circuit is activated.  
10 Pressure Adjustment Knob  
Place Set/Run switch up and turn on gas/air  
supply. Lift knob and turn to adjust pressure.  
Push knob down to lock in setting.  
Place switch down to cut or gouge.  
When set in down position, trigger must be  
held closed while cutting.  
5
Ready Light  
Use light to tell if unit is ready for operation.  
8
Pilot Arc Control Switch  
Place Set/Run switch down to begin cutting.  
Ref. ST-159 465-A / ST-800 701 / S-0818  
OM-217 Page 20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 5 MAINTENANCE & TROUBLESHOOTING  
5-1. Routine Maintenance  
. Maintain more often  
Y
Disconnectpower  
before maintaining.  
during severe conditions.  
Each Use  
Check Torch  
Tip, Electrode,  
And Shield Cup  
Check Gas/Air  
Pressure  
Every Week  
Check Shield Cup  
Shutdown System  
3 Months  
Replace  
Unreadable  
Labels  
Service Air  
Filter/Regulator  
Clean And  
Tighten Weld  
Terminals  
Tape Torn Outer  
Covering  
Adjust  
Spark  
Gaps  
Replace  
Cracked  
Parts  
Gas/Air Hose  
Torch Body, Cable  
6 Months  
Blow Out Or  
Vacuum Inside  
OR  
OM-217 Page 21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-2. Overload Protection: Fuses  
Y
Turn Off power and discon-  
nect input power before  
checkingfuses.  
Remove left side panel.  
Main Fuse F1  
1
F1 protects control transformer T2  
from overload. If F1 opens, the  
power source shuts down.  
2
3
4
5
6
7
Timer/Control Board PC1  
PC1 Fuse F1  
PC1 Fuse F2  
PC1 Fuse F4  
1
Isolator/Filter Board PC5  
PC5 Fuse F1  
Fuses on PC1 and PC5 protect the  
circuit boards from overload. If any  
fuse opens, Ready light goes off,  
and the unit does not cut.  
Replace fuses as needed. See  
Parts List for fuse ratings. Use  
proper tool when removing fuses.  
Reinstall side panel.  
4
2
6
5
3
7
Tools Needed:  
3/8 in  
Ref. ST-159 466-C / Ref. ST-135 352-A / Ref. SB-137 070-D / SA-141 468-C  
OM-217 Page 22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-3. Overload Protection: Trouble Lights & Checking Shield Cup Shutdown System  
If certain problems occur, the  
Ready light goes off, a trouble light  
comes on, and output stops.  
1
Gas/Air Or Shield Cup Light  
Lights if low gas/air pressure oc-  
curs, if shield cup is loose, or if o-  
ring is defective.  
1
Turn power Off, and check shield  
cup connection (see torch Owners  
Manual). Check for proper gas/air  
pressure (see Section 4-1).  
2
3
Check shield cup shutdown system  
once a week as shown.  
2
Torch-To-Tip Short Light  
Lights if a short exists between tip  
and electrode. Check tip and elec-  
trode (see torch Owners Manual).  
3
Temperature Light  
Checking Torch Shield Cup Shutdown System  
Lights if power source overheats  
(see Section 3-2).  
4
Torch Shield Cup  
4
Turn Power On and loosen shield  
cup. If shutdown system works  
properly, Ready light goes off and  
Gas/Air Or Shield Cup light comes  
on. If not, turn power Off and check  
for proper gas/air pressure (see  
Section 4-1), blocked or leaking  
hose, or loose shield cup (see torch  
Owners Manual).  
If system works properly, retighten  
cup and turn Off power.  
Ref. ST-800 713  
OM-217 Page 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-4. Adjusting Spark Gap  
Y
Turn Off power before ad-  
justing spark gap.  
Remove left side panel.  
Tungsten End Of Point  
1
Replace point if tungsten end dis-  
appears; do not clean or dress  
tungsten.  
2
Spark Gap  
Normal spark gap is 0.030 in (0.762  
mm).  
If adjustment is needed, proceed as  
follows:  
3
AdjustmentScrew  
Loosen screw. Place gauge of  
proper thickness in spark gap.  
4
Pressure Point  
Apply slight pressure at point until  
gauge is held firmly in gap. Tighten  
screw.  
4
3
Reinstall side panel.  
2
1
Tools Needed:  
3/8 in  
5/32 in  
0.030 in (0.762 mm)  
Ref. ST-159 466-C / S-0201  
OM-217 Page 24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-5. Torch And Work Cable Connections  
Y
Turn Off power before re-  
moving side panel.  
If torch or work cable needs to be  
removed or replaced, remove left  
side panel, and proceed as follows:  
1
2
3
4
5
Work Cable  
Work (+) Output Terminal  
Torch Cable  
Pilot Cable  
Torch () And Gas/Air Output  
Connector  
6
Pilot (+) Output Terminal  
Connect cables as shown.  
7
8
9
Terminal Strip 1T  
Connection Label  
Torch Switch Leads  
For hand-held torches, refer to label  
to connect leads. Reinstall side  
panel.  
10 Nut  
11 Hose Clamp  
1T  
For machine-held torches, tighten  
nut and clamp to secure cables.  
See Section 3-8 for remote control  
connections.  
8
1
71  
2
3
4
5
6
72  
84  
85  
64  
Hand-Held Torch  
1
Torch  
Switch  
2
5
4
3
N.O.  
Output  
Sensor  
63  
Command  
7
65  
Ref.  
8
Remote  
Jumper Com-  
9
66  
70  
43  
mon  
6
Panel  
10  
11  
Signal  
Machine-Held Torch  
1
9
7
Ground  
S-169 259  
3
OR  
4
Side View  
10  
11  
Tools Needed:  
1/2 in  
3/8 in  
Ref. ST-159 466-C / ST-800 702-B  
OM-217 Page 25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5-6. Troubleshooting  
Trouble  
Remedy  
No cutting output; Power light off; Place Power switch in On position.  
Trouble lights off; Ready light off; fan mo-  
tor FM does not run.  
Place line disconnect device in On position (see Section 3-10).  
Check line fuse(s) and replace if needed or reset circuit breakers (see Section 3-10).  
Check main fuse F1 and replace if needed (see Section 5-2).  
Have Factory Authorized Service Agent check contactor W.  
No cutting output; Power light on; Ready Be sure work clamp is connected.  
light on; Trouble lights off; fan motor FM  
running.  
Check for proper torch switch lead connections (see Sections 3-8 and 5-5).  
Check for for proper position of jumper link on terminal strip 1T (see Section 3-8).  
Have Factory Authorized Service Agent check contactor W, control relay CR3, and firing board PC2.  
No cutting output; Power light on; Ready Check fuses on timer/control board PC1 and isolator/filter board PC5 (see Section 5-2).  
light off; Trouble lights off; fan motor FM  
running.  
Have Factory Authorized Service Agent check timer/control board PC1.  
No control of output.  
Check for for proper position of jumper link on terminal strip 1T (see Sections 3-8).  
Have Factory Authorized Service Agent check Output control R1, timer/control board PC1, hall device  
HD1, and firing board PC2.  
No gas/air flow; Power light on; Ready Check fuses on timer/control board PC1 and isolator/filter board PC5 (see Section 5-2).  
light on; Trouble lights off; fan motor FM  
running.  
Check for proper torch connections (see torch Owners Manual).  
No gas/air flow; Power light on; Ready Check fuses on timer/control board PC1 and isolator/filter board PC5 (see Section 5-2).  
light off; Trouble lights off; fan motor FM  
running.  
No pilot arc or high frequency; difficulty Check fuses on timer/control board PC1 and isolator/filter board PC5 (see Section 5-2).  
in establishing an arc.  
Check and adjust spark gap, if needed (see Section 5-4).  
Check for damaged torch or torch cable (see torch Owners Manual).  
Have Factory Authorized Service Agent check control relay CR1, timer/control board PC1, and firing  
board PC2.  
Erratic pilot arc, difficulty in establishing Check for excessive moisture and/or contaminants in gas/air supply.  
an arc, and lowered cutting capacity.  
Check for dirty air filter/regulator and clean, if needed (see manufacturers instructions).  
Gas/Air Or Shield Cup Trouble light Place Set/Run switch in Run position.  
on; Ready light off.  
Check for sufficient gas/air supply pressure and correct gas/air pressure adjustment (see Section 4-1).  
Check torch shield cup and o-ring (see torch Owners Manual).  
Check for dirty air filter/regulator and clean, if needed (see manufacturers instructions).  
Have Factory Authorized Service Agent check timer/control board PC1.  
Torch-To-Tip Short Trouble light on; Check to make sure torch electrode is not touching tip inside the torch (see torch Owners Manual).  
Ready light off.  
Check to make sure torch lead connections are tight on terminal strip 1T (see Sections 3-8 and 5-5).  
OM-217 Page 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble  
Remedy  
Temperature Trouble light on; Ready ThermostatTP1 and/or TP2 open (overheating). Allow fan to run; the thermostat closes when the unit has  
light off.  
cooled (see Section 3-2).  
Have Factory Authorized Service Agent check timer/control board PC1.  
No high gas/air flow (cutting air), or de- Check for sufficient gas/air supply pressure and correct gas/air pressure adjustment (see Section 4-1).  
creased cutting ability.  
Have Factory Authorized Service Agent check reed switch RS1, high air solenoid AS2, and air circuitry.  
Fan motor FM does not run; Power light Check fan motor connections.  
and Ready light both on.  
Trouble lights not working.  
Have Factory Authorized Service Agent check indicator board PC3 and timer/control board PC1.  
Power light on; Trouble lights on; cutting Have Factory Authorized Service Agent check timer/control board PC1.  
output available.  
OM-217 Page 27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 6 ELECTRICAL DIAGRAMS  
SC-183 062-A  
Figure 6-1. Circuit Diagram For 60 Hertz Power Sources  
OM-217 Page 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SC-176 919-A  
Figure 6-2. Circuit Diagram For 50 Hertz Power Sources  
OM-217 Page 29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 7 HF IN PLASMA CUTTING  
7-1. High Frequency In Plasma Arc Cutting (PAC)  
1
2
Plasma Arc Torch  
1
High-Frequency Voltage  
Used inside torch to ionize gap  
between electrode and tip to help  
start the pilot arc.  
2
3
4
5
6
Electrode  
Pilot Arc  
Tip  
6
3
5
Shield Cup  
Work  
Plasma Arc Cutting (PAC)  
4
high_freq2 4/95 S-0753  
7-2. Sources Of High-Frequency Radiation From Incorrect Installation  
Cutting Zone  
11, 12  
50 ft  
(15 m)  
10  
9
14  
8
7
3
13  
2
4
1
6
5
S-0754  
Sources Of Direct High-Frequency  
Radiation  
5
6
Workpiece  
Work Table  
Sources Of Reradiation Of High  
Frequency  
10 UngroundedMetal Objects  
11 Lighting  
1
High-FrequencySource (Plasma Arc  
Cutting Power Source)  
Sources Of Conduction Of High  
Frequency  
2
3
4
Cables  
12 Wiring  
7
8
9
Input Power Cable  
Torch  
13 Water Pipes And Fixtures  
14 External Phone And Power Lines  
Line Disconnect Device  
Input Supply Wiring  
Work Clamp  
OM-217 Page 30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7-3. Correct Installation  
A. Worksite Requirements  
7
Cutting Zone  
3
50 ft  
(15 m)  
50 ft  
(15 m)  
5
1
6
2
8
4
8
Ground All  
Metal Objects  
And All Wiring  
In Cutting Zone  
Using #12 AWG  
Wire  
Ground  
Workpiece  
If Required  
By Codes  
9
Nonmetal Building  
11  
8
8
Metal Building  
10  
Ref. S-0755  
1
Plasma Arc Cutting Source  
5
Conduit Joint Bonding And Grounding  
Metal Building Requirements  
9 Metal Building Panel Bonding Methods  
Ground metal machine case, line disconnect  
device, input supply, and workpiece (if  
required).  
Electrically join (bond) all conduit sections  
using copper straps or braided wire. Ground  
conduit every 50 ft (15 m).  
Bolt or weld building panels together, install  
copper straps or braided wire across seams,  
and ground frame.  
2
Center Point Of Cutting Zone  
6
Water Pipes And Fixtures  
Ground water pipes every 50 ft (15 m).  
External Power Or Telephone Lines  
Midpoint between high-frequency source  
and cutting torch.  
10 Windows And Doorways  
Cover all windows and doorways with  
grounded copper screen of not more than  
1/4 in (6.4 mm) mesh.  
7
3
Cutting Zone  
Locate high-frequency source at least 50 ft  
(15 m) away from power and phone lines.  
A circle 50 ft (15 m) from center point in all  
directions.  
11 Overhead Door Track  
Ground the track.  
8
Grounding Rod  
4
Torch And Work Cables  
Consult the National Electrical Code for  
specifications.  
Keep cables close together.  
OM-217 Page 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SECTION 8 PARTS LIST  
. Hardware is common and  
not available unless listed.  
ST-800 934B  
Figure 8-1. Main Assembly  
OM-217 Page 32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Replace Coils at Factory or Authorized Factory Service Station  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Figure 8-1. Main Assembly  
Quantity  
. . . 1 . . . . . . . . . . . . . . . 015 531 . . HOOK, lift . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . . . 132 940 . . PANEL, side LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . . . 168 943 . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . . . 192 404 . . PANEL, side RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . . . 126 700 . . BRACKET, mtg heatsink LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . SR1 . . . . . 170 831 . . RECTIFIER, main (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . SCR1-3 . . . 168 065 . . . . POWER BLOCK, thyristor 55A 1200PIV . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . . . . . . . . . . . . . . 112 250 . . . . FOIL, interface heat transfer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . . . . . . . . . . . . . . 173 625 . . . . HEAT SINK, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 170 830 . . . . HEAT SINK, rect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . . . . TP2 . . . . . 129 552 . . . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 126 495 . . . . BUS BAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . C7-12 . . . . 127 082 . . . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . . . . . . . . . VR1 . . . . . 105 779 . . . . VARISTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . . . 126 701 . . BRACKET, mtg heatsink RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . . . 169 882 . . HF PANEL, (Fig 8-4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . CR1 . . . . . 188 633 . . CONTACTOR, def prp 40A 3P 120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 181 014 . . LINK, connecting contactor term . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 10 . . . . . . W . . . . . . 188 634 . . CONTACTOR, def prp 60A 3P 24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . CR3 . . . . . 114 780 . . CONTACTOR, def prp 60A 3P 115V (consisting of) . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 114 787 . . . . COIL, cntor 115V 60A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 114 786 . . . . LINK, connecting contactor terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . 2T . . . . . . 072 253 . . STUD, connection single 10-32 x .500 x 1.250 . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . C20 . . . . . 031 688 . . CAPACITOR, cer disc .01uf 1000VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 010 913 . . WASHER, flat brs .218 ID x .460 OD x .031thk . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 601 835 . . NUT, brs hex 10-32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . HD1 . . . . . 177 453 . . TRANSDUCER, current 200A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG18 . . . . 115 094 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4  
. . . 15 . . . . . . . . . . . . . . . 168 850 . . FRAME, center base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . T2 . . . . . . 174 308 . . TRANSFORMER, kVA 1/3 24-24 (200/230/460) . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . T2 . . . . . . 174 304 . . TRANSFORMER, kVA 1/3 24-24 (230/460/575) . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . T2 . . . . . . 174 306 . . TRANSFORMER, kVA 1/3 24-24-18 (220/380/415) . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . . TE1 . . . . . 038 126 . . TERMINAL ASSEMBLY, pri 3ph 3V (200/230/460) (consisting of) . . . . 1  
. . . 17 . . . . . TE1 . . . . . 168 854 . . TERMINAL ASSEMBLY, pri 3ph 3V (230/460/575) (consisting of) . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 601 835 . . . . NUT, brs hex 10-32 reg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . As Reqd  
. . . . . . . . . . . . . . . . . . . . . 038 058 . . . . TERMINAL BOARD, pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 038 887 . . . . STUD, pri bd brs 10-32 x 1.375 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
. . . . . . . . . . . . . . . . . . . . . 010 913 . . . . WASHER, flat brs .218 ID x .460 OD x .031thk . . . . . . . . . . . . . . . . . . 23  
. . . . . . . . . . . . . . . . . . . . . 038 618 . . . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7  
. . . . . . . . . . . . . . . . . . . . . 601 836 . . . . NUT, brs hex .250-20 jam hvy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
. . . . . . . . . . . . . . . . . . . . . 010 915 . . . . WASHER, flat brs .250 ID x .625 OD x .031thk . . . . . . . . . . . . . . . . . . . 6  
. . . . . . . . . . . . . . . . . . . . . 038 888 . . . . STUD, pri bd brs .250-20 x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 18 . . . C21-23 . . . . 091 141 . . CAPACITOR, cer disc. .0022uf 3000VAC . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 19 . . . . . . . . . . . . . . . . Fig 8-3 . . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . T1 . . . . . . 150 311 . . TRANSFORMER, pwr main 200/230/460 (consisting of) . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . . 149 734 . . . . COIL, pri/sec 200/230/460 LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . 131 559 . . . . COIL, pri/sec 200/230/460 (center & RH) . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . T1 . . . . . . 150 310 . . TRANSFORMER, pwr main 230/460/575 (consisting of) . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . . 149 736 . . . . COIL, pri/sec 230/460/575 LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . 135 984 . . . . COIL, pri/sec 230/460/575 center & RH . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . T1 . . . . . . 176 914 . . TRANSFORMER, pwr main 220/380/415 (consisting of) . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . . . 176 915 . . . . COIL, pri/sec 220/380/415 LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . . . 176 916 . . . . COIL, pri/sec 220/380/415 center & RH . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . TP1 . . . . . 119 581 . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . . . 168 944 . . HOSE, air 36 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-217 Page 33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Figure 8-1. Main Assembly  
Quantity  
. . . 24 . . . . . . . . . . . . . . . 010 296 . . FITTING, hose brs elb M 1/4NPT x .625-18RH . . . . . . . . . . . . . . . . . . . . 1  
. . . 25 . . . . AS1-3 . . . . 003 538 . . VALVE, 115VAC 2 way 1/4 IPS port 1/8orf . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . . . . . . VR2-5,7,8 . . 186 491 . . VARISTOR, w/terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 26 . . . . . . . . . . . . . . . 010 830 . . FITTING, piped brs nipple hex 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 27 . . . . . . . . . . . . . . . 071 270 . . FITTING, pipe brs tee st 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 28 . . . . . . . . . . . . . . . 169 688 . . FITTING, brs barbed M 3/16tbg x 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 29 . . . . . . . . . . . . . . . 010 323 . . CLAMP, hose .250-.625clp dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 30 . . . . . . . . . . . . . . . 124 961 . . HOSE, air 40 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 31 . . . . . . . . . . . . . . . 602 958 . . FITTING, brs barbed M 1/4tbg x 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 32 . . . . . . . . . . . . . . . 161 860 . . HOSE, SAE .250 ID x .500 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 33 . . . . . . . . . . . . . . . 161 308 . . FITTING, brs barbed M 1/4tbg x 1/4NPT .059 ID . . . . . . . . . . . . . . . . . . . 1  
. . . 34 . . . . . . . . . . . . . . . 132 753 . . HOSE, air 27 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 35 . . . . . . . . . . . . . . . 168 851 . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 36 . . . . . Z1 . . . . . . 140 118 . . STABILIZER, (1000 models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 36 . . . . . Z1 . . . . . . 139 709 . . STABILIZER, (1250 models) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 37 . . . . . . . . . . . . . . . . Fig 8-2 . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 38 . . . . . . . . . . . . . . . 600 317 . . CABLE, weld cop strd No. 4 (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . 30ft  
. . . 39 . . . . . . . . . . . . . . . 171 001 . . CLAMP, ground 100A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 601 225 . . INSULATOR, vinyl clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 132 463 . . SLEEVE, stop guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . . 127 854 . . CLAMP, stl cush 1.312dia x .343mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . . 010 021 . . CLAMP, stl cush .562dia x .343mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OPTIONAL  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-217 Page 34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
1
2
4
5
6
7
8
9
24  
10  
11  
12  
13  
23  
22  
14  
15  
21  
20  
. Hardware is common and  
18  
17  
16  
not available unless listed.  
19  
ST-800 935-A  
Figure 8-2. Panel, Front w/Components  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 37)  
. . . 1 . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . PL2 . . . . 125 521 . . LIGHT, ind grn lens 28V snap mtg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . S4-6 . . . . 089 085 . . SWITCH, tgl SPST 20A 125VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 4 . . . . . . . . . . . . . . 115 443 . . STAND-OFF, 6-32 x .750 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 5 . . . . PC3 . . . . 165 552 . . CIRCUIT CARD, display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG8 . . . 134 859 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 125 748 . . . . CONNECTOR, rect skt 22-18ga JST SVH-21T-1.1 . . . . . . . . . . . . . . . . . 6  
. . . 6 . . . . PL1 . . . . 157 958 . . LIGHT, ind white lens 28V snap mtg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . R1 . . . . . 035 897 . . POTENTIOMETER, CP std slot 1/T 2W 1K linear . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . . S1 . . . . . . 111 997 . . SWITCH, rocker SPST 10A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . . 110 375 . . STAND-OFF SUPPORT, PC card No. 6 screw . . . . . . . . . . . . . . . . . . . . . . 16  
. . . 10 . . . . PC1 . . . . 188 870 . . CIRCUIT CARD, control (1000 models) (consisting of) . . . . . . . . . . . . . . . 1  
. . . 10 . . . . PC1 . . . . 188 871 . . CIRCUIT CARD, control (1250 models) (consisting of) . . . . . . . . . . . . . . . 1  
. . . 11 . . . . F2 . . . . . *012 633 . . . . FUSE, mintr gl 1A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . F4 . . . . . *012 663 . . . . FUSE, mintr gl slo-blo 3A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . F1 . . . . . *012 653 . . . . FUSE, mintr gl .5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG3 . . . . 115 093 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 6  
. . . . . . . . PLG4,5 . . 131 052 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 16  
. . . . . . . . . PLG6 . . . . 115 091 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 10  
. . . 14 . . . . PC2 . . . . 097 772 . . CIRCUIT CARD, SCR firing circuit (60 Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . PC2 . . . . 107 510 . . CIRCUIT CARD, SCR firing circuit (50 Hz) . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
OM-217 Page 35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-2. Panel, Front w/Components (Fig 8-1 Item 37)  
. . . . . . . . . PLG1 . . . 081 379 . . CONNECTOR, rect 12skt plug Amp 1-87159-2 . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 081 378 . . CONNECTOR, rect skt 22-18ga Amp 102100-2 . . . . . . . . . . . . . . . . . . . . . 12  
. . . . . . . . . PLG2 . . . 090 469 . . CONNECTOR, rect 10skt plug Amp 1-87159-0 . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 081 378 . . CONNECTOR, rect skt 22-18ga Amp 102100-2 . . . . . . . . . . . . . . . . . . . . . 10  
. . . 15 . . . . PC4 . . . . 162 880 . . CIRCUIT CARD, filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . PLG14 . . . . 115 092 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 8  
. . . . . . . . PLG15 . . . . 115 093 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 6  
. . . 16 . . . . PC5 . . . . 141 467 . . CIRCUIT CARD, isolator/filter (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . F1 . . . . . *012 653 . . . . FUSE, mintr gl .5A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . PLG11 . . . 131 054 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 2  
. . . . . . . . PLG12 . . . . 115 092 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 8  
. . . . . . . . PLG13 . . . . 115 093 . . CONNECTOR & SOCKETS, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . . 113 746 . . . . CONNECTOR, rect skt 24-18ga Molex 39-00-0038 . . . . . . . . . . . . . . . . 6  
. . . 18 . . . . . . . . . . . . . 126 368 . . STAND-OFF SUPPORT, PC card No. 6 screw . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 19 . . . . . . . . . . . . +180 170 . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 20 . . . . . . . . . . . . . 024 376 . . BLANK, snap-in nyl .625mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 21 . . . . . . . . . . . . . 170 647 . . BUSHING, snap-in nyl 1.312 ID x 1.500mtg hole . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . . . . . . . . . . 134 900 . . STRAIN, relief cable flexible .270-.480 cable . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . . . . . . . . . . . . 171 007 . . KNOB, pointer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . 136 156 . . LABEL, warning precautionary plasma cutting equipment . . . . . . . . . . . . . 1  
*Recommended Spare Parts.  
+When ordering a component originally displaying a precautionary label, the label should also be ordered.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-217 Page 36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
Figure 8-3. Panel, Rear w/Components (Fig 8-1 Item 19)  
. . . 1 . . . R2,3 . . . . 126 736 . . RESISTOR, WW fxd 375W 20-161 ohm dual . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . F1 . . . . . *604 259 . . FUSE, crtg 3A 600V one time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 070 404 . . HOLDER, fuse crtg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 4 . . . . . . . . . . . . . . 032 611 . . BLADE, fan 14 in 3wg 23deg .375 bore CCW . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . 192 402 . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . . . . . . . . . . 168 944 . . HOSE, air 36 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . . . . . . . . . . 192 399 . . REGULATOR/FILTER, 250PSIG in 0-150PSIG out 1/4NPT . . . . . . . . . . . 1  
. . . 8 . . . . . . . . . . . . . 168 945 . . BRACKET, mtg air filter/regulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 9 . . . . . . . . . . . . . 168 252 . . NUT, knrl .187-12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 10 . . . . . . . . . . . . . 169 260 . . GASKET, neoprene 3.000 OD x 1.250 ID x .500 . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . . 117 125 . . GAUGE, air 0-160psi 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 12 . . . . . . . . . . . . . 188 962 . . HOSE, vinyl braided .125 ID x .312 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 13 . . . . . . . . . . . . . 015 733 . . FITTING, pipe brs nipple L 1/4NPT x 2.000 . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . . . . . . . . . . . 602 963 . . FITTING, pipe brs coupling 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 15 . . . . . . . . . . . . . 044 426 . . CONNECTOR, clamp cable .690/1.070 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 16 . . . . . . . . . . . . . 131 361 . . CHAMBER, plenum 14 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 17 . . . . R4 . . . . . 181 631 . . RESISTOR, w/mtg hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 18 . . . . FM . . . . . 116 190 . . MOTOR, 1/12hp 230V 1550RPM 50/60Hz 1.5A . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 047 838 . . BLANK, snap-in nyl 1.000mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
10  
9
. Hardware is common and  
8
not available unless listed.  
7
11  
6
1
5
12  
2
3
4
13  
14  
15  
18  
16  
17  
ST-800 936-A  
Figure 8-3. Panel, Rear w/Components  
*Recommended Spare Parts.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-217 Page 37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Item  
No.  
Dia.  
Mkgs.  
Part  
No.  
Description  
Quantity  
169 882  
Figure 8-4. HF Panel (Fig 8-1 Item 8)  
. . . 1 . . . . . . . . . . . . . 125 689 . . FITTING, pipe brs adapter bhd .562-18 x .750-16 . . . . . . . . . . . . . . . . . . . . 1  
. . . 2 . . . . . . . . . . . . . 169 883 . . STRIP, mtg torch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 3 . . . . . . . . . . . . . 605 884 . . NUT, stl hex jam .750-16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 4 . . . . . . . . . . . . . 010 604 . . FITTING, hose brs bushing 1/4NPT x .625-18 RH . . . . . . . . . . . . . . . . . . . 1  
. . . 5 . . . . . . . . . . . . . 071 270 . . FITTING, pipe brs tee st 1/4NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 6 . . . . S2 . . . . . 168 773 . . SWITCH, pressure air NO-NC cont adj 45 to 65 PSI . . . . . . . . . . . . . . . . . 1  
. . . 7 . . . . RS1 . . . . 125 508 . . RELAY, reed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . VR6 . . . . 186 505 . . VARISTOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . SN1 . . . . 186 538 . . SNUBBER ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 8 . . . C4,14 . . . 142 133 . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 9 . . WORK . . . 026 947 . . STAND-OFF, insul .250-20 x 1.000 lg x .312thd . . . . . . . . . . . . . . . . . . . . . 2  
. . . . . . . . . . . . . . . . . . . 038 328 . . STUD, brs .250-20 x 1.250 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . . 601 836 . . NUT, brs hex .250-20 jam hvy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3  
. . . 10 . . . . . . . . . . . . . 175 585 . . PANEL, mtg HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 11 . . . . . . . . . . . . . 605 538 . . CABLE TIE, 0-4.500 bundle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 12 . . . . . . . . . . . . . . 113 146 . . CABLE TIE MOUNT, for lashing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 13 . . . . T4 . . . . . 162 884 . . COIL, HF coupling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 14 . . . C3,16 . . . 096 761 . . CAPACITOR, mica .002uf 10000V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 15 . . . . . . . . . . . . . 010 886 . . STRIP, conductor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 16 . . . . T3 . . . . . 074 398 . . TRANSFORMER, high voltage 115V pri 3600V sec 30mA . . . . . . . . . . . . 1  
. . . 17 . . . . . . . . . . . . . 103 947 . . TUBING, stl .312 OD x 17ga wall x .937 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 18 . . . . . . . . . . . . . . 113 000 . . STRIP, mtg spark gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 19 . . . . . . . . . . . . . 020 622 . . HOLDER, points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 20 . . . . . G . . . . . *020 603 . . POINT, spark gap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2  
. . . 21 . . . . . . . . . . . . . 010 493 . . BUSHING, snap-in nyl .625 ID x .875mtg hole . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 22 . . . . 1T . . . . 073 586 . . BLOCK, term 20A 11P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . . . . . . . . . . . . . . . . 601 219 . . LINK, jumper term blk 20A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 23 . . C18,19 . . 126 450 . . CAPACITOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1  
. . . 24 . . . . . . . . . . . . . 169 884 . . FITTING, pipe brs adapter BHD .375-24 x .750-16 . . . . . . . . . . . . . . . . . . . 1  
8
7
9
3
2
10  
1
4
11  
12  
5
6
24  
23  
13  
21  
14  
22  
20  
15  
. Hardware is common and  
18  
16  
19  
not available unless listed.  
17  
ST-800 937-A  
Figure 8-4. HF Panel  
*Recommended Spare Parts.  
Item is not part of HF Panel.  
To maintain the factory original performance of your equipment, use only Manufacturers Suggested  
Replacement Parts. Model and serial number required when ordering parts from your local distributor.  
OM-217 Page 38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-217 Page 39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-217 Page 40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-217 Page 41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
OM-217 Page 42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Effective January 1, 1998  
(Equipment with a serial number preface of KJor newer)  
This limited warranty supersedes all previous Miller warranties and is exclusive with no other  
guarantees or warranties expressed or implied.  
LIMITED WARRANTY Subject to the terms and conditions  
below, Miller Electric Mfg. Co., Appleton, Wisconsin,  
warrants to its original retail purchaser that new Miller  
equipment sold after the effective date of this limited warranty  
is free of defects in material and workmanship at the time it is  
shipped by Miller. THIS WARRANTY IS EXPRESSLY IN  
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR  
*
APT, ZIPCUT & PLAZCUT Model Plasma Cutting  
Torches  
*
*
*
*
Remote Controls  
Accessory Kits  
Replacement Parts (No labor)  
Spoolmate 185  
IMPLIED, INCLUDING  
THE  
WARRANTIES OF  
MERCHANTABILITY AND FITNESS.  
Millers True Blue Limited Warranty shall not apply to:  
Within the warranty periods listed below, Miller will repair or  
replace any warranted parts or components that fail due to  
such defects in material or workmanship. Miller must be  
notified in writing within thirty (30) days of such defect or  
failure, at which time Miller will provide instructions on the  
warranty claim procedures to be followed.  
1. Items furnished by Miller, but manufactured by others,  
such as engines or trade accessories. These items are  
covered by the manufacturers warranty, if any.  
2. Consumable components; such as contact tips, cutting  
nozzles, contactors, brushes, slip rings, relays or parts  
that fail due to normal wear.  
Miller shall honor warranty claims on warranted equipment  
listed below in the event of such a failure within the warranty  
time periods. All warranty time periods start on the date that  
the equipment was delivered to the original retail purchaser,  
or one year after the equipment is sent to a North American  
distributor or eighteen months after the equipment is sent to  
an International distributor.  
3. Equipment that has been modified by any party other  
than Miller, or equipment that has been improperly  
installed, improperly operated or misused based upon  
industry standards, or equipment which has not had  
reasonable and necessary maintenance, or equipment  
which has been used for operation outside of the  
specifications for the equipment.  
1. 5 Years Parts 3 Years Labor  
MILLER PRODUCTS ARE INTENDED FOR PURCHASE  
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND  
PERSONS TRAINED AND EXPERIENCED IN THE USE  
AND MAINTENANCE OF WELDING EQUIPMENT.  
*
*
Original main power rectifiers  
Inverters (input and output rectifiers only)  
2. 3 Years Parts and Labor  
In the event of a warranty claim covered by this warranty, the  
exclusive remedies shall be, at Millers option: (1) repair; or  
(2) replacement; or, where authorized in writing by Miller in  
appropriate cases, (3) the reasonable cost of repair or  
replacement at an authorized Miller service station; or (4)  
payment of or credit for the purchase price (less reasonable  
depreciation based upon actual use) upon return of the  
goods at customers risk and expense. Millers option of  
repair or replacement will be F.O.B., Factory at Appleton,  
Wisconsin, or F.O.B. at a Miller authorized service facility as  
determined by Miller. Therefore no compensation or  
reimbursement for transportation costs of any kind will be  
allowed.  
*
*
*
*
*
*
Transformer/Rectifier Power Sources  
Plasma Arc Cutting Power Sources  
Semi-Automatic and Automatic Wire Feeders  
Inverter Power Supplies  
Warranty Questions?  
Intellitig  
Engine Driven Welding Generators  
(NOTE: Engines are warranted separately by the  
engine manufacturer.)  
Call  
1-800-4-A-MILLER  
for your local  
Miller distributor.  
3. 1 Year Parts and Labor  
Motor Driven Guns (w/exception of Spoolmate 185)  
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES  
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE  
REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE  
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR  
CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF  
PROFIT), WHETHER BASED ON CONTRACT, TORT OR  
ANY OTHER LEGAL THEORY.  
Process Controllers  
Positioners and Controllers  
Automatic Motion Devices  
Robots  
IHPS Power Sources  
Water Coolant Systems  
HF Units  
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN  
AND ANY IMPLIED WARRANTY, GUARANTY OR  
REPRESENTATION AS TO PERFORMANCE, AND ANY  
REMEDY FOR BREACH OF CONTRACT TORT OR ANY  
OTHER LEGAL THEORY WHICH, BUT FOR THIS  
PROVISION, MIGHT ARISE BY IMPLICATION,  
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE  
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR PARTICULAR  
PURPOSE, WITH RESPECT TO ANY AND ALL  
EQUIPMENT FURNISHED BY MILLER IS EXCLUDED  
AND DISCLAIMED BY MILLER.  
Grids  
Spot Welders  
Load Banks  
SDX Transformers  
Miller Cyclomatic Equipment  
Running Gear/Trailers  
Plasma Cutting Torches (except APT, ZIPCUT &  
PLAZCUT Models)  
Some states in the U.S.A. do not allow limitations of how long  
an implied warranty lasts, or the exclusion of incidental,  
indirect, special or consequential damages, so the above  
limitation or exclusion may not apply to you. This warranty  
provides specific legal rights, and other rights may be  
available, but may vary from state to state.  
*
*
Deutz Engines (outside North America)  
Field Options  
(NOTE: Field options are covered under True Blue  
for the remaining warranty period of the product they  
are installed in, or for a minimum of one year —  
whichever is greater.)  
In Canada, legislation in some provinces provides for certain  
additional warranties or remedies other than as stated  
herein, and to the extent that they may not be waived, the  
limitations and exclusions set out above may not apply. This  
Limited Warranty provides specific legal rights, and other  
rights may be available, but may vary from province to  
province.  
4. 6 Months Batteries  
5. 90 Days Parts and Labor  
*
MIG Guns/TIG Torches  
miller_warr 1/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Owners Record  
Please complete and retain with your personal records.  
Model Name  
Purchase Date  
Distributor  
Address  
Serial/Style Number  
(Date which equipment was delivered to original customer.)  
City  
State  
Zip  
Resources Available  
Always provide Model Name and Serial/Style Number.  
Contact your Distributor for:  
Welding Supplies and Consumables  
Options and Accessories  
Personal Safety Equipment  
Service and Repair  
To locate distributor nearest you call  
1-800-4-A-Miller.  
Miller Electric Mfg. Co.  
An Illinois Tool Works Company  
1635 West Spencer Street  
Appleton, WI 54914 USA  
Replacement Parts  
Training (Schools, Videos, Books)  
International HeadquartersUSA  
USA Phone: 920-735-4505 Auto-Attended  
USA & Canada FAX: 920-735-4134  
International FAX: 920-735-4125  
Technical Manuals (Servicing Information  
and Parts)  
Circuit Diagrams  
European Headquarters –  
United Kingdom  
Phone: 44 (0) 1204-593493  
FAX: 44 (0) 1204-598066  
Welding Process Handbooks  
www.MillerWelds.com  
Contact the Delivering Carrier for:  
File a claim for loss or damage during  
shipment.  
For assistance in filing or settling claims,  
contact your distributor and/or equipment  
manufacturers Transportation Department.  
PRINTED IN USA  
1999 Miller Electric Mfg. Co. 9/98  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Multiquip Oxygen Equipment MC3P Bamp;S User Manual
Multiquip Water Pump qp 402h User Manual
Musica Speaker System ADD A ZONE SYSTEMS User Manual
Mustang Survival Life Jacket MD3085 User Manual
Newcon Optik Hunting Equipment NC 3 12X50 User Manual
Nortel Networks Switch 5625HD User Manual
Olympus Camera Accessories PPO E03 User Manual
Omega Drums OMB DAQ 2416_4AO User Manual
Onkyo Headphones IE FC300 User Manual
Patterson Kelley Water Heater P K Compact User Manual