Part No. 206208-A
August 1999
4401 Great America Parkway
Santa Clara, CA 95054
Using the Model 5625HD
EtherSpeedII Switch Module
Download from Www.Somanuals.com. All Manuals Search And Download.
EC Declaration of Conformity
This product conforms to the provisions of Council Directive 89/336/EEC and 73/23/EEC. The
Declaration of Conformity is available on the Nortel Networks World Wide Web site at
Japan/Nippon Requirements Only
Voluntary Control Council for Interference (VCCI) Statement
Taiwan Requirements
Bureau of Standards, Metrology and Inspection (BSMI) Statement
Canada Requirements Only
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Model 5625HD EtherSpeedII Switch Module) does not exceed the Class A limits for
radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian
Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (Model 5625HD EtherSpeedII Switch Module) respecte les limites de bruits radioélectriques
visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillage radioélectrique du ministère
des Communications du Canada.
Nortel Networks Software License Agreement
NOTICE: Please carefully read this license agreement before copying or using the accompanying software or
installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement).
BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF
THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS
UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept
these terms and conditions, return the product, unused and in the original shipping container, within 30 days of
purchase to obtain a credit for the full purchase price.
206208-A
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
1. License Grant. Nortel Networks NA Inc. (“Nortel Networks”) grants the end user of the Software (“Licensee”) a
personal, nonexclusive, nontransferable license: a) to use the Software either on a single computer or, if applicable, on
a single authorized device identified by host ID, for which it was originally acquired; b) to copy the Software solely
for backup purposes in support of authorized use of the Software; and c) to use and copy the associated user manual
solely in support of authorized use of the Software by Licensee. This license applies to the Software only and does not
extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent
software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel
Networks Software License Agreement that accompanies such software and upon payment by the end user of the
applicable license fees for such software.
2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
Nortel Networks and/or its licensors retain all title and ownership in both the Software and user manuals, including
any revisions made by Nortel Networks or its licensors. The copyright notice must be reproduced and included with
any copy of any portion of the Software or user manuals. Licensee may not modify, translate, decompile, disassemble,
use for any competitive analysis, reverse engineer, distribute, or create derivative works from the Software or user
manuals or any copy, in whole or in part. Except as expressly provided in this Agreement, Licensee may not copy or
transfer the Software or user manuals, in whole or in part. The Software and user manuals embody Nortel Networks’
and its licensors’ confidential and proprietary intellectual property. Licensee shall not sublicense, assign, or otherwise
disclose to any third party the Software, or any information about the operation, design, performance, or
implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors; however,
Licensee may grant permission to its consultants, subcontractors, and agents to use the Software at Licensee’s facility,
provided they have agreed to use the Software only in accordance with the terms of this license.
3. Limited warranty. Nortel Networks warrants each item of Software, as delivered by Nortel Networks and properly
installed and operated on Nortel Networks hardware or other equipment it is originally licensed for, to function
substantially as described in its accompanying user manual during its warranty period, which begins on the date
Software is first shipped to Licensee. If any item of Software fails to so function during its warranty period, as the sole
remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be
included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the
Software is provided will be free from defects in materials and workmanship under normal use for a period of 90 days
from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is
returned to Nortel Networks during the warranty period along with proof of the date of shipment. This warranty does
not apply if the media has been damaged as a result of accident, misuse, or abuse. The Licensee assumes all
responsibility for selection of the Software to achieve Licensee’s intended results and for the installation, use, and
results obtained from the Software. Nortel Networks does not warrant a) that the functions contained in the software
will meet the Licensee’s requirements, b) that the Software will operate in the hardware or software combinations that
the Licensee may select, c) that the operation of the Software will be uninterrupted or error free, or d) that all defects
in the operation of the Software will be corrected. Nortel Networks is not obligated to remedy any Software defect that
cannot be reproduced with the latest Software release. These warranties do not apply to the Software if it has been (i)
altered, except by Nortel Networks or in accordance with its instructions; (ii) used in conjunction with another
vendor’s product, resulting in the defect; or (iii) damaged by improper environment, abuse, misuse, accident, or
negligence. THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE
IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Licensee is responsible
for the security of its own data and information and for maintaining adequate procedures apart from the Software to
reconstruct lost or altered files, data, or programs.
4. Limitation of liability. IN NO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR
ANY COST OF SUBSTITUTE PROCUREMENT; SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES; OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR
PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE, EVEN
IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT
SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT
EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE.
iv
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Government Licensees. This provision applies to all Software and documentation acquired directly or indirectly
by or on behalf of the United States Government. The Software and documentation are commercial products, licensed
on the open market at market prices, and were developed entirely at private expense and without the use of any U.S.
Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or
disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial
Computer Software––Restricted Rights clause of FAR 52.227-19 and the limitations set out in this license for civilian
agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS
252.227-7013, for agencies of the Department of Defense or their successors, whichever is applicable.
6. Use of Software in the European Community. This provision applies to all Software acquired for use within the
European Community. If Licensee uses the Software within a country in the European Community, the Software
Directive enacted by the Council of European Communities Directive dated 14 May, 1991, will apply to the
examination of the Software to facilitate interoperability. Licensee agrees to notify Nortel Networks of any such
intended examination of the Software and may procure support and assistance from Nortel Networks.
7. Term and termination. This license is effective until terminated; however, all of the restrictions with respect to
Nortel Networks’ copyright in the Software and user manuals will cease being effective at the date of expiration of the
Nortel Networks copyright; those restrictions relating to use and disclosure of Nortel Networks’ confidential
information shall continue in effect. Licensee may terminate this license at any time. The license will automatically
terminate if Licensee fails to comply with any of the terms and conditions of the license. Upon termination for any
reason, Licensee will immediately destroy or return to Nortel Networks the Software, user manuals, and all copies.
Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license.
8. Export and Re-export. Licensee agrees not to export, directly or indirectly, the Software or related technical data
or information without first obtaining any required export licenses or other governmental approvals. Without limiting
the foregoing, Licensee, on behalf of itself and its subsidiaries and affiliates, agrees that it will not, without first
obtaining all export licenses and approvals required by the U.S. Government: (i) export, re-export, transfer, or divert
any such Software or technical data, or any direct product thereof, to any country to which such exports or re-exports
are restricted or embargoed under United States export control laws and regulations, or to any national or resident of
such restricted or embargoed countries; or (ii) provide the Software or related technical data or information to any
military end user or for any military end use, including the design, development, or production of any chemical,
nuclear, or biological weapons.
9. General. If any provision of this Agreement is held to be invalid or unenforceable by a court of competent
jurisdiction, the remainder of the provisions of this Agreement shall remain in full force and effect. This Agreement
will be governed by the laws of the state of California.
Should you have any questions concerning this Agreement, contact Nortel Networks, 4401 Great America Parkway,
P.O. Box 58185, Santa Clara, California 95054-8185.
LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT, UNDERSTANDS IT, AND
AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. LICENSEE FURTHER AGREES THAT THIS
AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN NORTEL NETWORKS AND
LICENSEE, WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND
COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS
AGREEMENT. NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST NORTEL
NETWORKS UNLESS NORTEL NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT, INCLUDING AN
EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT.
206208-A
v
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Preface
Before You Begin ............................................................................................................. xv
How to Get Help ............................................................................................................xviii
Chapter 1
Overview of the Model 5625HD Switch Module
Overview of the EtherSpeedII Switch Module ................................................................1-1
Features of the Model 5625HD Switch Module ..............................................................1-3
Physical Description .......................................................................................................1-5
Command Line Interface ...................................................................................1-7
SNMP MIB Support ...........................................................................................1-7
Spanning Tree Protocol 802.1d Support ..................................................................1-7
Support for Virtual LANs ..........................................................................................1-8
Filtering ....................................................................................................................1-8
Hot-Swapping Capability ..........................................................................................1-8
About the Model 500xBH/BHC Backplane .....................................................................1-9
LEDs ......................................................................................................................1-10
10/100 Mb/s UTP Autonegotiation Ports ................................................................1-10
Chapter 2
Planning a Network with the Model 5625HD
Switch Module
Physical Configuration Guidelines ..................................................................................2-1
Connecting to Ethernet Hubs and Network Devices ................................................2-2
206208-A
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Configuration Examples ...................................................................................2-3
Desktop Switch with ATM Uplinks ............................................................................2-7
Segment Switch in an Enterprise Network ...............................................................2-9
Multi-Link Trunking .................................................................................................2-11
Default Port Configuration ............................................................................................2-12
Chapter 3
Installing the Model 5625HD Switch Module
Required Tools and Equipment ......................................................................................3-5
Making 10/100 Mb/s Connections ..................................................................................3-8
Connecting Terminals and Management Stations ..........................................................3-9
Removing and Replacing the Switch Module ...............................................................3-11
Removing a Switch Module ....................................................................................3-12
Installing the Replacement Switch Module ............................................................3-13
Reconfiguring the Replacement Switch Module ....................................................3-13
Chapter 4
Troubleshooting
Preliminary Steps ...........................................................................................................4-2
Previous Module Configuration Incompatibility ...............................................................4-2
Model 5625HD Switch Module Startup Failure ...............................................................4-3
Port Connection Problems ..............................................................................................4-4
Appendix A
Technical Specifications
viii
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Cables and Connectors
UTP Cabling .................................................................................................................. B-2
10BASE-T/100BASE-TX MDI Ports and MDI-X Ports ................................................... B-2
UTP Cables and Connectors ......................................................................................... B-4
Using Category 5 Unshielded Twisted Pair Cables ....................................................... B-5
Using Shielded Twisted Pair Cables .............................................................................. B-6
Appendix C
LEDs
Index
206208-A
ix
Download from Www.Somanuals.com. All Manuals Search And Download.
x
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Figures
Figure 1-1. EtherSpeedII Switch Modules in a Network Center .................................1-2
Figure 2-1. Network Example .....................................................................................2-4
Figure 2-2. Connecting Servers to Dedicated Ports ...................................................2-5
Figure 2-3. Replacing a Bridge ..................................................................................2-6
Figure 2-4. Desktop Switch with ATM Uplinks ............................................................2-8
Figure 2-5. Segment Switch in an Enterprise Network ..............................................2-9
Figure 2-7. Multi-Link Trunking Example ..................................................................2-11
Figure 3-2. Model 5005BH Chassis Backplanes ........................................................3-4
Figure 3-3. Inserter/Extractor Levers in Vertical Position ...........................................3-6
Figure 3-4. Installing the Module ................................................................................3-7
Figure 3-5. Seating the Backplane Connectors ..........................................................3-7
Figure 3-6. Releasing the Backplane Connectors ....................................................3-12
Figure B-1. MDI-X Internal Crossover (RJ-45 Example) ........................................... B-2
Figure B-3. 10BASE-T/100BASE-TX Ethernet UTP Crossover Cable ...................... B-4
Figure B-4. Fast Ethernet Type 1 Balun Media Adapter ............................................ B-6
Figure C-1. LED Display for the Model 5625HD Switch Module ................................ C-1
Figure C-2. RJ-45 LEDs for the Model 5625HD Switch Module ................................ C-3
206208-A
xi
Download from Www.Somanuals.com. All Manuals Search And Download.
xii
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Tables
Table B-1.
Table B-2.
10BASE-T/100BASE-TX MDI-X Port Pin Assignments .......................... B-4
Pairs in an RJ-45 Crossover Cable ......................................................... B-5
Table C-1.
LEDs on the Model 5625HD Switch Module ........................................... C-2
206208-A
xiii
Download from Www.Somanuals.com. All Manuals Search And Download.
xiv
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
This guide provides an overview of the Nortel Networks™ Model 5625HD
EtherSpeedII 24-Port Autonegotiating Switch Module and information about
installing the module. This switch module introduces high-density Ethernet 10/
100 autonegotiation frame switching into the Model 500xBH/BHC ATM/Router
Backplane.
Centillion™ EtherSpeedII™ technologies and the features described in “Features of
the Model 5625HD Switch Module” on page 1-3.
Configuring the EtherSpeed switch modules is described in Using SpeedView 4.0
for Windows and Release Notes for SpeedView 4.1. For more information about
this topic, see “Related Publications” on page xvi.
Before You Begin
This guide is intended for local area network administrators who are responsible
for installing, configuring, or maintaining a network and have the following
background:
•
•
Familiarity with Ethernet network administration
Familiarity with the tools and procedures for installing and operating sensitive
electronic equipment
•
Understanding of Nortel Networks network management concepts and
terminology
206208-A
xv
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Related Publications
For information about the Centillion switches, refer to the following related
publications:
•
Using SpeedView 4.0 for Windows (Bay Networks® part number 893-891-D)
Describes this application, which is used for configuring the module.
•
Release Notes for Centillion Platform 4.1
(Bay Networks part number 203315-B)
Describes the updates to the SpeedView application for the 4.1 software
release.
•
Reference Guide for the Centillion 50/100 and Model 5000BH Switches
(Bay Networks part number 893-01006-C)
Provides reference information about switching terminology and concepts;
describes configuration examples using Centillion 50/100 and Model
500xBH/BHC switches.
•
•
•
•
Reference Guide for the Centillion Command Line Interface 4.0
(Bay Networks part number 893-00985-C)
Describes setup and configuration procedures for Centillion switches using
the command line interface.
Installing the Model 5000BH ATM/Router Backplane
(Bay Networks part number 893-00949-A)
Provides installation instructions for the Model 5000BH ATM/Router
Backplane in the Model 5000 chassis.
Installing the Model 5005BH ATM/Router Backplane
(Bay Networks part number 893-01056-A)
Provides installation instructions for the Model 5005BH ATM/Router
Backplane in the Model 5005 chassis.
Installation and Reference for the Model 5000 Chassis
(Bay Networks part number 893-598-C)
Provides installation instructions and maintenance information for the
Model 5000 Chassis.
xvi
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
•
•
Installation and Reference for the Model 5005 Chassis
(Bay Networks part number 893-696-A)
Provides installation instructions and maintenance information for the
Model 5005 Chassis.
Release Notes for the Centillion Platform Release 3.2
(Bay Networks part number 896-00189-C)
You can print selected technical manuals and release notes free, directly from the
which you need documentation. Then locate the specific category and model or
version for your hardware or software product. Using Adobe Acrobat Reader, you
can open the manuals and release notes, search for the sections you need, and print
them on most standard printers. You can download Acrobat Reader free from the
You can purchase selected documentation sets, CDs, and technical publications
through the collateral catalog. The catalog is located on the World Wide Web at
support.baynetworks.com/catalog.html and is divided into sections arranged
alphabetically:
•
•
•
The “CD ROMs” section lists available CDs.
The “Guides/Books” section lists books on technical topics.
The “Technical Manuals” section lists available printed documentation sets.
206208-A
xvii
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
How to Get Help
If you purchased a service contract for your Nortel Networks product from a
distributor or authorized reseller, contact the technical support staff for that
distributor or reseller for assistance.
If you purchased a Nortel Networks service program, contact one of the following
Nortel Networks Technical Solutions Centers:
Technical Solutions Center
Telephone Number
Billerica, MA
800-2LANWAN (800-252-6926)
800-2LANWAN (800-252-6926)
33-4-92-96-69-68
Santa Clara, CA
Valbonne, France
Sydney, Australia
Tokyo, Japan
61-2-9927-8800
81-3-5402-7041
xviii
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 1
Overview of the Model 5625HD Switch Module
•
•
•
•
•
Overview of the EtherSpeedII switch module (this page)
Features of the switch module (page 1-3)
Physical description of the switch module (page 1-5)
Switch configuration and management (page 1-6)
Model 500xBH/BHC backplane architecture (page 1-9)
Overview of the EtherSpeedII Switch Module
EtherSpeedII switch modules provide 10/100 megabits per second (Mb/s)
autonegotiation ports that support servers, routers, or dedicated connections to
users (Figure 1-1). The switch modules can also support multiple users through a
shared-media hub connection to a port.
Each EtherSpeedII switch module is installed in a single slot of a Model 500xBH/
BHC chassis. You can use SpeedView™ network management software to
configure and manage the modules.
206208-A
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Model 5625HD EtherSpeed 10/100
24-Port Autonegotiating
Switch Modules
Model 5720M ATMSpeed
MDA MCP Module
Model 5720M ATMSpeed
MDA MCP Module
BayStack Ethernet Hub
100 Mb/s
Model 5000BH
chassis
UTP 10/100 connections
to users
Router
9342EA
Figure 1-1.
EtherSpeedII Switch Modules in a Network Center
The Model 5625HD switch module provides 24 RJ-45 10/100 Mb/s
autonegotiating switched Ethernet connections for the Model 500xBH/BHC
ATM/Router Backplane for the System 500x chassis. The switch module
connectivity features of the Model 500xBH chassis.
For Ethernet connectivity, the Model 5625HD switch module RJ-45 connectors
accept Category 3 and 5 unshielded twisted pair (UTP) or shielded twisted pair
(STP) cable connections. For more information about cabling, refer to
Appendix B, “Cables and Connectors.”
Note: Category 3 UTP cable can be used only for fixed 10 Mb/s port
operation. It is not used for 100 Mb/s or 10/100 autonegotiating port operation.
1-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview of the Model 5625HD Switch Module
Features of the Model 5625HD Switch Module
The Model 5625HD switch module offers the following features:
•
•
•
•
•
•
Wire-speed, port-to-port, packet transfer
Single-slot design to fit into the System 500xBH/BHC chassis
Autonegotiation of Ethernet 10/100 Mb/s speed
Autonegotiation of half- or full-duplex mode on dedicated switch ports
Layer 2 MAC-based switching
Local frame switching, module-to-module switching, backplane switching,
and riser switching
•
•
•
•
•
200 MHz RISC processor
24 RJ-45 UTP network interface connectors
Front-panel LEDs to indicate module and port operational status
Port-based virtual LANs (VLANs)
Protocol-based VLANs
Protocol-sensitive VLANs classifies packets based on protocol types. Most
customers have multiple protocols per LAN segment, so a switch port needs
to support multiple VLANs based on different protocol types. This feature
allows you to separate data based on protocols and not on physical limitations.
•
IEEE 802.1Q Tag Recognition Support
The Model 5625HD switch module supports recognition of VLAN tagged
frames based on IEEE 802.1Q tags. Frames entering a Model 5625HD switch
module port that contain an 802.1Q tag are mapped to a corresponding
VLAN. Based on the final destination, the frame is sent as either an
Ethernet-type frame or an 802.1Q VLAN tagged frame. VLAN membership
is to be assigned by any combination of port with either tag or protocol.
•
•
•
•
•
Support for IEEE 802.1d Spanning Tree
Content-addressable memory (CAM) support for 8192 entries
Port steering/port mirroring
Input and output filtering supported by switching software
Hardware support for IP multicast
206208-A
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
•
Support for RMON Management Information Base (MIB)
–
–
–
–
Ethernet Statistics Group
Ethernet History Group
Ethernet Alarm Group
Ethernet Event Group
•
•
Ability to install, remove, and replace a module in an operational chassis
(hot-swap)
Hardware Assist Multi-Protocol over ATM (MPOA)
MPOA is the ATM Forum standard that specifies a method to efficiently
transport intersubnet unicast data in a LANE environment. MPOA uses
LANE and NHRP processes to allow direct shortcut virtual channel
connections (VCCs) to be established for intersubnet communication without
requiring passage through a router. The intrasubnet communication continues
to be supported over LANE. For IP, Nortel Networks has adopted MPOA as
the standard to implement layer 3 switching in an ATM network.
•
•
Improved performance in segmentation and reassembly (SAR) to 3.2 gigabit
Multi-Link Trunking (MLT)
1-4
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview of the Model 5625HD Switch Module
Physical Description
The Model 5625HD switch module (Figure 1-2) consists of a printed circuit board
with a metal module faceplate. The module includes captive retaining screws and
inserter/extractor levers on the top and bottom of the front panel.
Metal frame
Captive retaining
screw
Power supply
Inserter/extractor
lever
LED display
matrix
Model 5000BH
backplane connector
3.2 Gb/s SAR
MAC
(Media Access
Controller)
Phy
10/100BASE-TX
ports
Common
Management
Bus connector
Circuit board
9362FA
II
Figure 1-2.
Model 5625HD EtherSpeed 24-Port Autonegotiating Switch
Module
206208-A
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
There are 24 RJ-45 ports on the Model 5625HD switch module that automatically
detect speed and duplex mode. (For more information about cables, refer to
Appendix B, “Cables and Connectors.”)
Each Model 5625HD switch module occupies one slot in a Model 500x BH/BHC
chassis. You can install a maximum of 10 Model 5625HD switch modules, along
with two master control processor (MCP) switch modules, in a Model 5000BH/
BHC chassis or a maximum of five Model 5625HD switch modules, and one
MCP switch module, in a Model 5005BH chassis.
Switch Configuration and Management
You manage and configure a Model 5625HD switch module through access to an
installed MCP module in the Model 500xBH/BHC chassis with the following
network management features:
•
•
•
SpeedView for Windows 4.1 and greater
Command line interface (CLI)
Simple Network Management Protocol (SNMP) agent with System 5000 MIB
extensions
•
Trivial File Transfer Protocol (TFTP) support
SpeedView
SpeedView is a network management application that runs on Microsoft®
Windows® 95 or Windows 98 and Windows NT® and provides a graphical user
interface to set up your switch. SpeedView allows you to monitor and control
network traffic and to perform advanced operations such as filter configuration.
For more information about SpeedView, refer to Using SpeedView 4.0 for
Windows and Release Notes for SpeedView 4.1.
Optivity Network Management System™ (NMS) provides enterprise-wide
configuration and monitoring support for the Model 500xBH/BHC chassis
switches. Configuration support is provided using SpeedView, which is integrated
with Optivity NMS. Expanded View™, OmniView™, Network Atlas™, Threshold
Manager™, and other Optivity® applications provide comprehensive monitoring
and troubleshooting support. For more information about Optivity network
management software, refer to your Optivity documentation.
1-6
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview of the Model 5625HD Switch Module
Command Line Interface
The CLI provides an out-of-band interface for the initial setup of basic
configuration parameters such as IP address and bridging mode. For more
information about the CLI structure and commands, refer to Reference Guide for
the Centillion Command Line Interface.
SNMP MIB Support
The System 5000BH/BHC MCP modules support an SNMP-compatible agent
with private MIB extensions. Built-in SNMP agent support ensures compatibility
with existing network management tools. The MCP modules support MIB-I and
MIB-II (RFC 1213) standards that provide access to detailed management
statistics.
Using SpeedView, you can configure SNMP traps to be generated automatically
for conditions such as unauthorized access attempts or changes in operating status
on individual ports.
TFTP Support
TFTP is a supported Transmission Control Protocol/Internet Protocol (TCP/IP)
service used to download software and configuration information to the MCP
module memory. TFTP allows you to transfer an updated switch agent and
configuration files from a remote server to flash memory. You can perform a
transfer over the network or through a serial connection to the installed MCP
module.
Spanning Tree Protocol 802.1d Support
The Model 5625HD switch module software supports the Spanning Tree Protocol
as specified in the IEEE 802.1d standard. The Spanning Tree Protocol is
implemented to detect and eliminate logical loops in a bridged or switched
network. When multiple paths exist, the spanning tree algorithm configures the
network so that a bridge or switch uses only the most efficient path. If that path
fails, the protocol automatically reconfigures the network to make another path
become active, thus sustaining network operations.
206208-A
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Support for Virtual LANs
Using the Model 5625HD switch module, you can group one or more physical
ports to form a virtual LAN that constitutes a single broadcast domain.
Virtual LANs (VLANs) are formed when broadcast domains are configured
across multiple switches. Each Ethernet segment is an independent physical
segment with its own collision domain, but all segments within a VLAN appear to
the user as a broadcast domain.
Filtering
Filtering capabilities for the Model 5625HD switch module are implemented in
system hardware and controlled by system software. Refer to the appropriate
Centillion release guides for descriptions of the supported filtering capabilities,
features, and availability.
Hot-Swapping Capability
A Model 5625HD switch module can be inserted into or removed from a chassis
without interrupting service to other modules within the Model 500xBH/BHC
chassis. This feature is called “hot-swapping.”
Caution: Be sure to remove cables from all ports on the module, or disable all
the ports through the management interface, prior to hot-swapping.
1-8
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
About the Model 500xBH/BHC Backplane
The Model 500xBH/BHC ATM/Router Backplane integrates the two bus
technologies shown in Figure 1-3 and Figure 1-4.
Note: The Model 5000BH and 5000BHC backplanes are identical with the
exception of an additional shared 100 Mb/s backplane on the Model
5000BHC. The Model 5625HD switch module does not connect to these
shared backplanes. The Model 5625HD switch module can be used with the
Model 5000BH and 5000BHC backplanes without altering the module’s
performance.
PPX router bus
Centillion ATM bus
Centillion ATM bus
Slot
2
3
4
5
6
7
8
9
10 11 12 13
6750EC
Figure 1-3.
Model 5000BH/BHC ATM/Router Backplane Bus Structure
PPX router bus
Centillion ATM bus
Slot
2
3
4
5
6
7
7849EA
Figure 1-4.
Model 5005BH ATM/Router Backplane Bus Structure
206208-A
1-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
LEDs
LEDs on the module indicate port operating status and speed (Figure 1-5). The
numbers on the LEDs correspond to the port numbers. For more information
about the operation of the LEDs, refer to Appendix C, “LEDs.”
5625HD
10/100 Switch Host
Annunciator
Port Status
1
2
3
4
5
6
7
8
9
100 13 100
100 14 100
100 15 100
100 16 100
100 17 100
100 18 100
100 19 100
100 20 100
100 21 100
Port number
Port speed
Port LEDs
10 100 22 100
11 100 23 100
12 100 24 100
9341EA
Figure 1-5.
LEDs on the Model 5625HD Switch Module
A Model 5625HD switch module contains 24 10/100 Mb/s autonegotiating
Ethernet ports with shielded RJ-45 connectors. The RJ-45 connectors accept
Category 3 and 5 UTP or STP cable and are wired as MDI-X ports to connect end
stations to patch panels, without using crossover cables. See Appendix B, “Cables
and Connectors,” for information about wiring and pin assignments.
1-10
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 2
Planning a Network with the Model 5625HD
Switch Module
Installing the Model 5625HD EtherSpeedII 24-Port Autonegotiating Switch
Module in a network can significantly improve LAN performance. This chapter
chapter includes the following topics:
•
•
Physical configuration guidelines (this page)
Typical network configuration examples (page 2-3)
Physical Configuration Guidelines
Follow the basic guidelines in Appendix A, “Technical Specifications,” and
Appendix B, “Cables and Connectors,” when you plan a network using the
Model 5625HD switch module.
206208-A
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Connecting to Ethernet Hubs and Network Devices
You connect the ports of the Model 5625HD switch module to the front panel,
wired as MDI-X connections. This wiring allows you to use a straight-through
cable between the Model 5625HD switch module and the patch panel.
To connect the ports on the patch panel to another Ethernet switch or an Ethernet
hub, follow these guidelines:
•
Personal computers (PCs) and servers typically have network interface
controllers (NICs) that are configured as MDI connections. To connect these
devices, use a straight-through cable.
•
Hubs and other switches typically have connectors that are configured as
MDI-X. Some hubs and switches have ports that are set by a toggle switch for
either MDI or MDI-X operation.
port, use a crossover cable.
— To connect a port set for MDI to the Model 5625HD switch module port,
use a straight-through cable.
For connector specifications for MDI-X ports, refer to Appendix B, “Cables and
Connectors.”
2-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning a Network with the Model 5625HD Switch Module
Network Configuration Examples
The Model 5625HD switch module is an adaptable switch suitable for use in
sample network configuration.
This section describes the following Ethernet switching applications:
•
•
•
•
Replacement for a bridge port (page 2-6)
Desktop switch with ATM uplinks in a wiring closet (page 2-7)
Segment switch in a wiring closet with ATM uplinks to a network center
switch (page 2-9)
•
Desktop switch and frame-to-cell converter (page 2-10)
206208-A
2-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Model 5625HD
Switch Modules
Model 5000BH Chassis
Redundant,
load-balanced
risers to closets
Network
Center
Model 5000BH Chassis
Workgroup
servers
ATM
A
Router
B
C
ATM
10/100 Mb/s
Redundant,
network center
switches
VLAN D
Enterprise servers
9380EA
Figure 2-1.
Network Example
2-4
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning a Network with the Model 5625HD Switch Module
Giving a Server a Dedicated Port
on the Model 5625HD switch module improves server response time and
increases throughput capacity. For even higher performance, the server could
be upgraded to 100 Mb/s and the Model 5625HD switch module would
autonegotiate for 100 Mb/s.
In Figure 2-2, the “Before” example shows clients and servers sharing the same
network segment. The “After” example shows the same clients assigned to
different segments through a shared hub (either 10/100 Mb/s or directly
connected) and the original servers connected to switch ports on a Model
500xBH/BHC chassis. In addition, two servers have been added through 10/100
Mb/s connections.
Before
Servers
Clients
Clients
Segment
Model 5625HD EtherSpeed 24-Port
10/100 Autonegotiating
Switch Modules
After
Model 5720M ATMSpeed
MDA MCP Module
10 Mb/s
Servers
10 Mb/s
100 Mb/s
100 Mb/s
100 Mb/s
Segment
Segment
Servers
10 Mb/s
clients
100 Mb/s
clients
10 or 100 Mb/s
clients
9344EA
Figure 2-2.
Connecting Servers to Dedicated Ports
206208-A
2-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Replacing a Bridge
Using a switch instead of a bridge in the network can increase the aggregate
network bandwidth. The “After” example in Figure 2-3 shows one server
connected to a dedicated 10BASE-T port. It also shows the other server and
additional clients attached using dedicated 100BASE-TX connections. This
network configuration allows you to have switched 10 Mb/s Ethernet along with
segmented 10 Mb/s Ethernet to conserve ports.
Before
Servers
Clients
Clients
Segment
Segment
Bridge
Model 5625HD EtherSpeed 24-Port
10/100 Autonegotiating
Switch Modules
After
Model 5720M ATMSpeed
MDA MCP Module
10 Mb/s
10 Mb/s
Server
100 Mb/s
100 Mb/s
100 Mb/s
Server
Segment
Segment
10 Mb/s
clients
100 Mb/s
clients
10 or 100 Mb/s
clients
9345EA
Figure 2-3.
Replacing a Bridge
2-6
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning a Network with the Model 5625HD Switch Module
Desktop Switch with ATM Uplinks
In the example shown in Figure 2-4, the Model 5625HD switch module provides
up to 24 RJ-45 switched Ethernet (10/100 Mb/s) ports to connect to desktops, with
redundant high-speed ATM OC-3c and OC-12c ports to connect to an ATM
backbone. This network configuration can support small to large wiring closets.
Figure 2-4 on page 2-8 shows a sample network providing ATM uplinks to a
Model 5000BH/BHC chassis. Servers are connected to the network through the
Model 5000BH/BHC chassis, and network stations are connected to the 10/
100BASE-T ports on the Model 5625HD switch modules. The chassis are
dual-homed with ATM OC-3c and OC-12c uplinks to the Model 5000BH/BHC
chassis. Model 5000BH/BHC chassis can be interconnected with multiple ATM
links.
206208-A
2-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Data Center
Model 5000BH chassis
Model 5000BH chassis
Servers
Servers
100 Mb/s
100 Mb/s
100 Mb/s
ATM
100 Mb/s
ATM
Wiring Closet
ATM ATM ATM
ATM ATM ATM
Model 5000BH
chassis
10 Mb/s
100 Mb/s
100 Mb/s
10 Mb/s
100 Mb/s
100 Mb/s
10 or 100 Mb/s attached clients
9346EA
Figure 2-4.
Desktop Switch with ATM Uplinks
2-8
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning a Network with the Model 5625HD Switch Module
Segment Switch in an Enterprise Network
To achieve a gradual transition from shared media to switched networks, you can
use the Model 5625HD switch module to aggregate traffic from stations
connected to one or more hubs. Figure 2-5 shows such a network with switches
used to connect shared-media hubs to a backbone switch. Stations connected to
the Model 5000BH/BHC switch are associated with different segments through
the configuration switching feature.
Data Center
Model 5000BH Chassis with shared-media modules
Model 5625HD EtherSpeed 24-Port 10/100
Autonegotiating Switch Modules
ATM Router
Servers
ATM
100 Mb/s
100 Mb/s
10 Mb/s
Wiring Closet
100 Mb/s
10 Mb/s
Shared-media
Model 5000BH
Chassis
BayStack
Hubs
Clients
9347EA
Figure 2-5.
Segment Switch in an Enterprise Network
206208-A
2-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Desktop Switch and Frame-to-Cell Converter
For wiring closets with higher densities and lower bandwidth requirements, you
stackable switch products such as the BayStack 301 and BayStack 350T switches
(providing frame switching) to an ATM backbone (providing cell switching). The
stackable switches and the 24 RJ-45 10/100 Mb/s switched Ethernet ports on the
Model 5625HD switch module provide desktop connectivity.
Figure 2-7 shows a network with a Model 5625HD switch module used to connect
BayStack 301 and 350T switches to the Model 5000BH/BHC chassis in a data
center. The 10/100 Mb/s ports on the Model 5625HD switch module provide
high-speed connections to the BayStack™ switches. The Model 5625HD switch
module provides switched 10 Mb/s or 100 Mb/s capability for higher-bandwidth
desktop connectivity and can upgrade to 100 Mb/s with a client NIC upgrade.
Data Center
Model 5000BH chassis
Model 5000BH chassis
Server
Server
100 Mb/s
100 Mb/s
ATM
ATM
ATM
Wiring Closet
Model 5000BH chassis with
Model 5625HD EtherSpeed 24-Port 10/100
Autonegotiating Switch Modules
100 Mb/s
100 Mb/s
BayStack 301
switch
BayStack 350T
switches
3
5
0
F
1
0
/1
0
0
Autosense
Switch
3
5
0
F
1
0
/1
0
0
Autosense
Switch
10/100 Mb/s
clients
9348EA
Figure 2-6.
Desktop Switch and Frame-to-Cell Converter
2-10
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning a Network with the Model 5625HD Switch Module
Multi-Link Trunking
Multi-Link Trunking (MLT) allows up to four physical connections for the same
media type and speed to be grouped and treated as a single logical link. MLT
improves performance between two switches or between a switch and a server.
MLT allows data to be carried over multiple 100 Mb/s full-duplex links connected
to the same device, thus improving performance. Figure 2-7 shows that
connecting multiple BayStack 450 ports into a Model 5625HD switch module
allows the data to load share across those multiple ports, and overall performance
is improved.
Model 5005BH Chassis
BayStack 450-24T
100 Mb/s
100 Mb/s
MLT
connection
9381EA
Figure 2-7.
Multi-Link Trunking Example
206208-A
2-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Default Port Configuration
The Model 5625HD switch module is shipped preconfigured with the settings
listed in Table 2-1.
Table 2-1.
Parameter
Factory Defaults for the Model 5625HD Switch Module
Factory Default
Configurable Options
Switching mode
Spanning Tree Protocol
State
Transparent
Transparent
None, IEEE
Enable/Disable
Enable/Disable
Auto 10/100
2–32
None
Enable
Filters
Disable (none)
Port speed/display
Spanning tree group
Priority
Auto
2
128
10
0–255
Path cost
1–65535
Predefined SpeedView Configurations
SpeedView offers several predefined configurations. You may simply choose one
of these without having to configure individual ports. Predefined configurations
are available for the following applications:
•
•
All transparent switching with no Spanning Tree support
All transparent switching with IEEE 802.1d Spanning Tree support
You must enter additional configuration information if you are using any of the
following features:
•
•
•
•
ATM
VLANs
Filtering
Combinations of bridging modes and Spanning Tree Protocol not offered as
defaults
Instructions for using these features appear in Using SpeedView 4.0 for Windows
and Release Notes for SpeedView 4.1.
2-12
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 3
Installing the Model 5625HD Switch Module
This chapter describes how to install a Model 5625HD EtherSpeedII 24-Port
Autonegotiating Switch Module in the Model 500xBH/BHC chassis and includes
the following information and procedures:
•
(this page)
•
•
•
•
•
•
•
Using required tools for installation (page 3-5)
Installing a switch module (page 3-6)
Checking module LEDs (page 3-8)
Making 10/100 Mb/s connections (page 3-8)
Connecting terminals and management stations (page 3-9)
Checking the module connection to the backplane (page 3-11)
Removing and replacing a switch module (page 3-11)
206208-A
3-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Arranging Modules in a Model 500xBH/BHC Chassis
The Model 5000BH ATM/Router Backplane has two Centillion ATM buses and a
PPX bus to accommodate switch and router modules. The Centillion ATM buses
span two slot ranges in a Model 5000BH/BHC chassis: slots 2 through 7 and 8
through 13. When you install a Model 5625HD switch module in one of these slot
ranges, you must also install an MCP switch module (such as the Model 5720M
ATMSpeed™ MCP module) in the same range of slots. You can attach up to six
System 5000 switch modules (one of which must be an MCP module) to each
Centillion ATM bus in a Model 5000BH/BHC chassis.
The PPX bus spans slots 2 through 13. A router module may be installed in any of
these slots. Router modules for the Model 5000BH ATM/Router Backplane
include the Model 5380 Ethernet Router Module, the Module 5580 Token Ring
Router Module, and the Model 5782 Centillion Multiprotocol Engine Module.
Any slot designated for switch modules can also be used for a standard Ethernet,
token ring, or FDDI, or ATM module with the appropriate backplane(s) installed
in the chassis.
3-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
Figure 3-1 shows the logical relationship between the Model 5000BH ATM/
Router Backplane and shared-media backplanes in a Model 5000BH/BHC
chassis.
Slot 2
Slot 13
PPX bus (2–13)
Model
5000BH
backplane
Centillion
ATM bus (2–7, 8–13)
Fast Ethernet (1–14)
Model
5000BHC
backplane
Power
Common
management bus
Model
5000BH
backplane
Ethernet (1–14)
Token ring
(1–14 or 1–7, 8–14)
Slot 1
Slot 14
8662EA
Figure 3-1.
Model 5000BH/BHC Chassis Backplanes
Note: The Model 5000BH and Model 5000BHC backplanes are identical with
the exception of an additional shared 100 Mb/s backplane on the Model
5000BHC. The Model 5625HD switch module does not connect to this shared
backplane. The Model 5625HD switch module can be used with the Model
5000BH and Model 5000BHC backplanes without altering the module’s
performance.
206208-A
3-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
The Model 5005BH ATM/Router Backplane (see Figure 3-2) has a single
Centillion ATM bus and PPX® bus. The Centillion ATM bus spans slots 2 through
7 in the Model 5005BH chassis. When you install a System 5000 Model 5625HD
switch module in one of these slot ranges, you must also install an MCP switch
module (such as the Model 5720M ATMSpeed MCP module) in the same range of
slots. You can attach up to six System 5000 switch modules (one of which must be
an MCP module) in a Model 5005BH chassis.
The PPX bus spans slots 2 through 7. A router module may be installed in any of
these slots. Router modules for the Model 5000BH ATM/Router Backplane
include the Model 5380 Ethernet Router Module, the Module 5580 Token Ring
Any slot designated for switch modules can also be used for a standard Ethernet,
token ring, or FDDI, or ATM module with the appropriate backplane(s) installed
in the chassis. Slot 1 is reserved for the clock module.
Figure 3-2 shows the logical relationship between the Model 5005BH ATM/
Router Backplane and shared-media backplanes in a Model 5005BH chassis.
Slot 2
Slot 7
PPX bus (2–7)
Model
5005BH
backplane
Centillion
ATM bus (2–7)
Power
Common
management bus
Model
5005BH
backplane
Ethernet (1–8)
Token ring (1–8)
Slot 1
Slot 8
8749EA
Figure 3-2.
Model 5005BH Chassis Backplanes
3-4
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
Required Tools and Equipment
You need the following tools and equipment to install a Model 5625HD switch
module:
•
•
Medium flat-tip screwdriver
Grounded antistatic mat and wrist strap or discharge leash
Caution: The System 5000 equipment uses electronic components that are
sensitive to static electricity. Static discharge from your clothing or other
fixtures around you can cause damage. Take all possible precautions to prevent
static discharge damage when working with printed circuit boards.
Place each module on a grounded antistatic mat until you are ready to install
the module. If you do not have an antistatic mat, wear a wrist strap or
discharge leash to free yourself of static before touching any of the modules, or
free yourself of static by touching the metal chassis before handling the
module.
206208-A
3-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Installing the Switch Module
To install and secure the Model 5625HD switch module in the chassis:
1. Remove the filler panel from the chassis slot where you intend to install
the module.
2. Extend the switch module inserter/extractor levers to the vertical position
(Figure 3-3).
4689
Figure 3-3.
Inserter/Extractor Levers in Vertical Position
Note: These instructions illustrate installing a Model 5625HD switch module
in a Model 5000BH/BHC chassis. The instructions also apply to a Model
5005BH chassis.
3. Align the top and bottom edges of the metal printed circuit board carrier
with the slot card guides at the top and bottom of the slot.
4. Slide the switch module into the chassis until you feel it engage the
backplane (Figure 3-4).
The inserter/extractor levers should still be in the vertical position and in
contact with the front of the chassis. Do not push the switch module all the
way into the chassis.
3-6
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
3649.1
Figure 3-4.
Installing the Module
5. Rotate the inserter/extractor levers in toward the center of the switch
module front panel to seat the backplane connectors (Figure 3-5).
Model 5000
4690.2
Figure 3-5.
Seating the Backplane Connectors
6. Use the flat-tip screwdriver to tighten the captive retaining screws at both
ends of the switch module front panel.
206208-A
3-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Checking LEDs
Immediately after you have installed a Model 5625HD switch module, watch the
LEDs on the front panel. If the board is installed and functioning properly, the
following LED color sequence occurs:
•
•
The annunciator lights amber and then lights green.
or port management disabled status.
•
Each Port Speed LED lights green when you have a 100 Mb/s Ethernet
connection and is off when you have a 10 Mb/s connection.
See Appendix C, “LEDs,” for the LED definitions.
Making 10/100 Mb/s Connections
The 10/100 Mb/s jacks on the Model 5625HD switch module accept standard
UTP or STP cable connections.
To connect network devices to the 10/100 Mb/s ports on the Model 5625HD
switch module, follow these guidelines:
•
•
•
Use Category 3 or 5 UTP or STP cable with RJ-45 connectors for the ports on
the Model 5625HD switch module.
Use straight-through cables to connect the network interface card (NIC) in a
Use a crossover cable to connect to ports configured as MDI-X (such as
Ethernet hubs).
For more information about cables, connectors, and connector pin assignments,
see Appendix B, “Cables and Connectors.”
3-8
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
Connecting Terminals and Management Stations
This section provides information about connecting terminals or PCs to the
service port on the Model 500xBH/BHC chassis. For information about
connecting a management station to an MCP module, refer to the using guide
shipped with that module.
Refer to Using SpeedView 4.0 for Windows and Release Notes for SpeedView 4.1
for information about advanced configuration and monitoring of the switch.
To connect a terminal to the Model 500xBH/BHC chassis service port, you need
the following equipment:
•
A TTY-compatible terminal or a portable computer with a serial port and the
ability to emulate a TTY-compatible terminal. The terminal communication
parameters should be set for:
— 9600 baud (default)
— 8 data bits
— No parity
— 1 stop bit
— No handshaking
— Standard ASCII code
•
An RS-232 modem cable with a female DB-9 connector to connect to the
service port on the chassis front panel. The cable should use the service port
pin assignments that are specified in Installation and Reference for the
Model 5000 Chassis and Installation and Reference for the Model 5005
Chassis.
206208-A
3-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
The other end of the cable must have a connector appropriate to the serial port
on your computer or terminal. (Most terminals or computers use a male DB-9
or DB-25 connector.) See Table 3-1 for the pin assignments.
Note: RS-232 signals on other pins (such as DTR, CTS, and CD) are ignored.
Table 3-1.
Service Port Pin Assignments
To Service Port
Terminal
DB-9 Pins
DB-25 Pins
Function
DB-9 Pins
Function
2
3
5
3
2
7
Receive data
Transmit data
Signal ground
2
3
5
Transmit data
Receive data
Signal ground
To connect the terminal to the chassis service port:
1. Connect the RS-232 cable to the terminal (or a computer in terminal-
emulation mode) and to the chassis service port.
2. Set the terminal communication parameters as described earlier in this
section.
3. Turn on the terminal; adjust contrast and brightness as required.
3-10
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
Checking the Module Connection to the Backplane
Note: The Model 5625HD switch module communicates through the MCP
rather than the common management bus (CMB). Modules without the CMB
interface do not display on the Slot Selection menu, and there is no way to
verify that they are connected to the backplane using the service port menus.
Removing and Replacing the Switch Module
This section provides the following information and procedures:
•
•
•
Conditions for replacing a Model 5625HD switch module
Removing a Model 5625HD switch module
Installing the replacement Model 5625HD switch module
Conditions for Replacing a Switch Module
The following hardware conditions indicate that the switch module needs to be
replaced:
•
The annunciator on the front panel remains off. This condition indicates that a
•
The annunciator remains amber. This condition indicates that the module has
failed to boot.
For information about using LEDs to troubleshoot an EtherSpeed switch module,
see Appendix C, “LEDs.”
For information about troubleshooting other System 500x modules, refer to the
using guide for the specific module.
206208-A
3-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Removing a Switch Module
To remove a Model 5625HD switch module from the chassis:
Note: Be sure to remove cables from all ports on the module, or disable all the
ports through the management interface, prior to hot-swapping.
1. Use a flat-tip screwdriver to loosen the two captive retaining screws that
secure the module to the chassis.
the chassis. The screws are held in place on the module front panel by locking
washers.
2. Rotate the top and bottom inserter/extractor levers away from the center
of the switch front panel to release the module from the backplane
connectors (Figure 3-6).
Model 5000
Captive retaining
screw
Inserter/extractor
lever
3249.10
Figure 3-6.
Releasing the Backplane Connectors
3-12
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Installing the Model 5625HD Switch Module
3. Slide the Model 5625HD switch module out of the chassis.
Hold the front panel with one hand while you support the bottom of the switch
module with the other hand.
4. Place the Model 5625HD switch module on an antistatic mat until you are
ready to put it back into the chassis.
5. If you are not installing another Model 5625HD switch module, install a
Installing the Replacement Switch Module
To install the replacement switch module, follow the procedure described in
“Installing the Switch Module” on page 3-6.
Reconfiguring the Replacement Switch Module
The Model 5625HD switch module keeps the configuration of an identical
replacement module. If the replacement is not a Model 5625HD switch module,
the module needs to be reconfigured after it has been replaced. Follow the
procedure described in “Installing the Switch Module” on page 3-6.
206208-A
3-13
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Chapter 4
Troubleshooting
This chapter provides suggestions for troubleshooting problems with a Model
5625HD EtherSpeedII 24-Port Autonegotiating Switch Module and includes the
following topics:
•
•
Incompatibility with the configuration of a previously installed module
(page 4-2)
•
•
Startup failure in the Model 5625HD switch module (page 4-3)
Problems with the port connection (page 4-4)
To expedite support when you call Nortel Networks, please have the following
information ready:
•
•
Hardware configuration
Software configuration (including the image file version number and
SpeedView version number)
•
•
•
Network diagram
Module or switch part number and serial number for the suspected module
Brief description of the problem
206208-A
4-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Preliminary Steps
If you suspect problems with a newly installed Model 5625HD switch module,
start troubleshooting by checking the following items:
•
•
•
•
Check all power cable connections and power sources.
Check network cable connections to be sure connectors are properly seated.
Make sure the cables are the correct type, with correctly wired connectors.
Check the LEDs for indication of link status.
Previous Module Configuration Incompatibility
Symptom: A module in a powered-on chassis fails to start up.
different module type installed in it previously.
The Model 5625HD switch module keeps the configuration of an identical
replacement module. If the replacement is not a Model 5625HD switch module,
the module needs to be reconfigured after it has been replaced. Follow the
procedure described in “Installing the Switch Module” on page 3-6.
To check for possible incompatibility in module type:
1. Connect a SpeedView management station to the MCP port on the
switch, using either the direct connection or the modem connection.
This procedure is described in Using SpeedView 4.0 for Windows and Release
Notes for SpeedView 4.1.
2. Select the Map menu.
If this module is displayed with all ports disabled, the MCP module is not able
to manage this module because there is no stored configuration information
about the module. You must enable the ports and download the new
configuration to the MCP module.
After you download the new configuration, you are prompted to reset the
switch.
4-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Model 5625HD Switch Module Startup Failure
Symptom: All LEDs are off on the Model 5625HD switch module.
This condition indicates that the links on all ports are not functioning.
To resolve the problem:
1. Use the CLI, SpeedView, or other network management tool to verify
port status.
retaining screws have been tightened.
3. Remove and reinsert the failing module.
If the problem persists, contact Nortel Networks customer support. Be ready to
give the service representative the information listed on page 4-1.
206208-A
4-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Port Connection Problems
Symptom: The LED on an Ethernet port is off.
If an LED does not light when traffic is present, there may be a port connection
problem.
To resolve the problem:
1. Verify whether or not the port is enabled, using SpeedView or the CLI.
a. From the Map window in SpeedView, choose Switch and then choose
Configure.
When the configuration information has been downloaded to the
management station, check the port state. The port state should be either
enabled or disabled.
b. From the Map window, choose Statistics.
When the statistics information has been downloaded to the management
station, check the port state. If the port state is Down, the port is receiving
no link signal or it is disabled.
c. From a configuration terminal connected to the serial port on the
switch, access the CLI.
Use the show port command and specify the module number and port
number for the suspected port. When the port information is displayed,
verify that port_state is up and SPTstate is forwarding.
2. Verify that the cable is correctly connected.
Disconnect and reseat the cable at the Model 5625HD switch module port and
at the patch panel or punchdown block. Check the port LED for a change in
status.
4-4
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
3. Verify that the port is transmitting and receiving data frames.
a. Check the green RJ-45 LED, which indicates a data exchange.
Refer to Appendix C, “LEDs,” for additional information.
b. From the Map window in SpeedView, choose Statistics.
When the statistics information is displayed at the management station,
verify that the octet counts for transmit and receive are incrementing.
Also verify that the frame counts for transmit and receive unicast traffic
and for multicast traffic are incrementing.
c. From a configuration terminal connected to the serial port on the
switch, access the CLI.
Use the show port command and specify the module number and port
number for the suspected port. Verify that the following counters are
incrementing:
•
•
•
•
•
•
•
•
InOctet
OutOctet
InUcastPkt
OutUcastPkt
MulticastTransmittedOk
MulticastReceivedOk
BroadcastTransmittedOk
BroadcastReceivedOk
4. If the port still fails, try inserting it into another switch network or
shared segment.
If the port functions correctly, check the status of the first switch network
or shared segment.
If the port fails to function, contact Nortel Networks customer support. Be
ready to give the service representative the information listed on page 4-1.
206208-A
4-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Technical Specifications
This appendix provides technical specifications for the Model 5625HD
EtherSpeedII 24-Port Autonegotiating Switch Module. For connector pin
assignments and other information about cables, see Appendix B, “Cables and
Connectors.”
Industry Protocols and
Standards
ISO/IEC 8802-3 (ANSI/IEEE 802.3) Fifth Edition
1996-07-29
Clause 4: Medium Access Control and
Clause 14: Twisted-Pair Medium Attachment Unit
(MAU) and Baseband Medium Type 10BASE-T.
IEEE Std. 802.3u-1995, Media Access Control
(MAC) Parameters, Physical Layer, Medium
Attachment Units, and Repeater for 100 Mb/s
Operation, Type 100BASE-T (Clauses 21-30).
Interface Options
Data Rates
RJ-45 connectors (8-pin modular)
10 Mb/s and 100 Mb/s switched Ethernet
Autonegotiating Features
10/100 Mb/s speed autonegotiation
Half/Full Duplex autonegotiation
Microprocessor
64-bit MIPS 5000 series processor, 200 MHz per
module
Memory
Processing
8 MB
Dynamically Allocated Buffer Pool 16 MB
CAM (Content Addressable
Memory)
8,192 entries
SIMM Flash Memory
4 MB
206208-A
A-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Electrical Specifications
Power Consumption
Thermal Rating
57 W (max)
194.5 BTU/hr (max)
Physical Specifications
Dimensions
(L) 10.5 in. x (W) 12.25 in. x (H) 1.0 in.
[(L) 26.7 cm x (W) 31.7 cm x (H) 2.5 cm
Weight
Module alone: 4 lbs, 14 oz. (2.05 kg)
Packaged: 6 lbs (2.7 kg)
Environmental Specifications
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Operating Altitude
Free Fall/Drop
5° to 40° C
-25° to 70° C
85% maximum relative humidity, noncondensing
95% maximum relative humidity, noncondensing
10,000 ft (3,000 m) (max)
ISO 4180-s, NSTA 1A
IEC 68-2-6/34
Vibration
IEC 68-2-27-29
Shock/Bump
Electromagnetic Emissions
Meets requirements of
FCC Part 15, Subpart B, Class A
EN 55 022 (CISPR 22:1985), Class A
VCCI Class 1 ITE
Electromagnetic Susceptibility
Electrostatic Discharge (ESD)
Radiated Electromagnetic Field
EC 801-2, Level 2
EC 801-2, Level 2
EC 801-4, Level 2
Electrical Fast Transient/Burst
Electrical Surge
IEC 801-5, Levels 1 and 2
Complies with EN 50082-1 (European CE mark
requirements)
A-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Technical Specifications
Safety Agency Approvals
International Electrical Code of 950 (IEC 950)
Underwriters Laboratories (UL 1950)
Canadian Standards Association (C22.2 No. 950)
or Bi-national Standard (UL1950 and C22.2 No. 950)
equivalent to UL and cUL
European Union (EN60950)
Norma Oficial Mexicana (NOM-19-SCFI)
Meets UL-94-V1 (PWB) flammability requirements
Mean Time Between Failure
347,000 hours*
(MTBF)
Cabling Specifications
(Model 5625HD)
Types: Category 3 or 5 unshielded twisted pair
(UTP) or shielded twisted pair (STP)
Note: Category 3 UTP cable may be used only for
10 Mb/s port operation, not for 100 Mb/s or 10/100
Mb/s autonegotiating port operation where the
negotiated rate may be 100 Mb/s.
Maximum Length: 100 meters (cable plant and patch
cables inclusive)
Connector Types: Shielded RJ-45 connectors
*See the Disclaimer on page ii of this manual.
206208-A
A-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B
Cables and Connectors
This appendix provides general information about 10BASE-T and 100BASE-TX
cabling and connections.
UTP Cable Length Limitations
All 10BASE-T/100BASE-T ports on the Model 5625HD switch module support
the maximum lengths for twisted pair cable that are specified in the IEEE 802.3
10BASE-T/100BASE-TX Ethernet specification. This specification defines the
maximum segment length in terms of the performance characteristics of the cable
media, which can vary according to cable type. In most networks, cable runs are
less than 100 meters (m) to ensure that data is not distorted or lost.
For UTP links of #24 AWG cable between a network interface (transceiver or
10BASE-T/100BASE-TX network interface controller) and a hub or between
hubs, these performance specifications are normally met by a cable run of
100 m (330 ft) or less, including any patch cables and cross-connect cables.
The 10BASE-T/100BASE-TX standard specifies this length as a design objective.
The Model 5625HD switch module is designed to support a maximum cable
length of 100 m.
Your cable plant can contain Category 3 or 5 UTP cables, up to a maximum length
of 100 m between the end station and the Model 5625HD switch module. Use an
appropriate patch cable to connect your cable to this module. For additional
information, refer to Appendix A in Planning and Managing a System 5000
Network (see “Related Publications” in the Preface).
206208-A
B-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
UTP Cabling
A 10BASE-T/100BASE-TX connection between two ports requires two twisted
pairs. The transmit data (TD) pair carries data out from the port transmitter. The
receive data (RD) pair carries data to the port receiver.
The 10BASE-T/100BASE-TX TD and RD circuits must be connected as follows:
•
Individual conductors must provide pin-to-pin continuity (TD+ to RD+,TD-
to RD-, and so on) between the Model 5625HD switch module port and the
attached MDI port on a transceiver or other network interface.
•
•
Each signal circuit must use a single twisted pair throughout the link.
Standard Ethernet patch panels and cables provide the previous features.
10BASE-T/100BASE-TX MDI Ports and MDI-X Ports
In the 10BASE-T/100BASE-TX standard, MDI is the electrical and mechanical
interface specified for the 10BASE-T/100BASE-TX transceiver or network
interface card connector (for example, on the station at the end of a link). MDI
port pins 1 and 2 carry the transmit (TD) signal, and pins 3 and 6 carry the receive
(RD) signal as shown in Figure B-1.
1
2
1
2
Transmit
Receive
Twisted pairs
3
6
3
6
Receive
Transmit
MDI port network
interface card or
transceiver port
Host module MDI-X port
(transmit and receive
connections reversed)
2008EF
Figure B-1.
MDI-X Internal Crossover (RJ-45 Example)
B-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Cables and Connectors
The Model 5625HD switch module receives data on pins 1 and 2 and transmits its
data on pins 3 and 6. The host module ports implement this MDI standard
crossover internally and are called MDI-X (the X for crossover), as shown in
Figure B-1. All Model 5625HD switch module 10BASE-T ports are MDI-X
standard.
Two simple rules govern all usual RJ-45 connections from each Model 5625HD
switch module 10BASE-T/100BASE-TX port to the 10BASE-T/100BASE-TX
port on another device:
•
A straight-through cable (MDI to MDI-X) is customarily used for connection
to a station NIC, to a transceiver, or to a cable plant patch panel.
•
A crossover cable or adapter (MDI-X to MDI-X; as shown in Figure B-2) is
customarily used for connection to another switch or hub port.
Twisted
pairs
1
2
1
2
Receive
Receive
Transmit
3
6
3
6
Transmit
MDI-X port
2007.4
Figure B-2.
MDI-X to MDI-X External Crossover (RJ-45 Example)
Making the crossover externally with a crossover cable or adapter that exchanges
the TD and RD wire pairs (as shown in Figure B-2) is possible but has the
following disadvantages:
•
Because a crossover cable is not standard, you might have to specially order
one or make your own.
•
Having crossover cables and standard cables that resemble one another in a
network invites confusion.
Caution: Make any crossover cable you use look obviously different from
normal straight-through cables and put a tag on each end; for example, use a
distinctive color like yellow and put a tag labeled “X-over” on each end.
206208-A
B-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
UTP Cables and Connectors
Table B-1 shows the pin assignments for 10BASE-T/100BASE-TX ports in the
standard MDI-X configuration.
Table B-1.
10BASE-T/100BASE-TX MDI-X Port Pin Assignments
RJ-45 Connector Port
Pin #
MDI-X Ports
1
2
3
4
5
6
7
8
Receive data +
Receive data –
Transmit data +
Not used
1
2
3
4
5
6
7
8
Amber LED
Green LED
Not used
Transmit data –
Not used
9364EA
Not used
Figure B-3 shows a 10BASE-T/100BASE-TX Ethernet UTP crossover cable used
to connect an Ethernet hub directly to the Model 5625HD switch module.
RD+
RD-
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
RD+
RD-
TD+
TD+
Unused
Unused
TD-
Unused
Unused
TD-
Unused
Unused
Unused
Unused
6740.2
Figure B-3.
10BASE-T/100BASE-TX Ethernet UTP Crossover Cable
B-4
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Cables and Connectors
Pin 1 crosses to pin 3, and pin 2 crosses to pin 6. To build this cable, you must
cross pairs. The pairs are listed in Table B-2, with an example of the color
combinations found in two typical cables.
Table B-2.
Pairs
Pairs in an RJ-45 Crossover Cable
Example 1
Example 2
Color Combinations
Color Combinations
1 and 2
3 and 6
4 and 5
7 and 8
Orange/white and white/orange
Green/white and white/green
Blue/white and white/blue
Orange and blue
Yellow and black
Red and green
Brown and gray
Brown/white and white/brown
Using Category 5 Unshielded Twisted Pair Cables
Unshielded twisted pair (UTP) cable is the recommended wiring option for
100BASE-TX Fast Ethernet, as specified in the IEEE 802.3 standard for Ethernet.
Fast Ethernet recommended UTP cable consists of four pairs of twisted insulated
copper conductors bound in a single plastic sheath. The 100BASE-TX Fast
Ethernet transmissions are implemented through two-pair or four-pair Category 5
UTP wiring using standard shielded RJ-45 connectors. Category 5 cable is
certified to handle up to 100 MHz bandwidth. The EIA/TIA T568A standard
recommends the installation of Category 5 UTP cable for 100 Mb/s networks.
Use the following guidelines to ensure that your cables perform to specifications:
•
•
•
Certification—Make sure that your Category 5 UTP cable has completed the
Underwriters Laboratories (UL) or Electronic Testing Laboratories (ETL)
certification process.
Terminating method—To minimize crosstalk noise, maintain the twist ratio of
the cable up to the point of termination (untwist at any termination should not
exceed 0.5 in.).
Pairing options—For optimal performance from your cable plant, use the
EIA-T568A Commercial Building Wiring Standard pairing option at each end
of the cable. The terminating hardware offered by most major manufacturers
is correctly color-coded for proper wire placement according to that standard.
206208-A
B-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Using Shielded Twisted Pair Cables
Type 1 shielded twisted pair (STP) cabling also operates with 10BASE-T Ethernet
and 100BASE-TX Fast Ethernet. Type 1 STP cable consists of tinned-copper
braided shield surrounding two data-grade twisted pairs of #22 AWG solid copper
conductors that have individual or S-shaped shields of aluminum-backed
insulating tape or metallized Mylar foil.
Note: A balun media adapter is required when connecting 100-ohm RJ-45
100BASE-TX ports to a 150-ohm STP cable plant. This adapter provides
impedance matching between UTP (100-ohm) and STP (150-ohm) cabling.
patch panel to the work area wall outlet.
Type 1 cable generally is terminated with an IBM four-position (MIC) data
connector. Nortel Networks Fast Ethernet supports 100BASE-TX Fast Ethernet
over STP media through the application of a specialized balun media adapter, also
referred to as a Type 1 balun (Figure B-4). When adapting 150-ohm STP cable
plants for Fast Ethernet applications, balun media adapters are required at both the
hub and station ends of the STP cable plant. Media adapters (such as AMP part
number 558421-1) are available that plug into the RJ-45 patch cable connectors,
allowing the patch cable to connect with an IBM data connector. The media
adapter and patch cable provide impedance matching between UTP (100-ohm)
and STP (150-ohm) cabling.
6737
Figure B-4.
Fast Ethernet Type 1 Balun Media Adapter
Note: For additional information about AMP Type 1 balun media adapters
(part number 558421-1), contact your AMP reseller or distributor. The user
should verify that the combination of the STP cable plant and the impedance-
matching baluns meets the requirements of the applicable LAN standard.
B-6
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C
LEDs
This appendix describes the LED displays for the Model 5625HD switch module.
The LED display (Figure C-1) consists of two LEDs for each port. The LEDs
labeled with the port number indicate specific operating status. The LEDs labeled
100 indicate the port speed.
5625HD
10/100 Switch Host
Annunciator
Port Status
1
2
3
4
5
6
7
8
9
100 13 100
100 14 100
100 15 100
100 16 100
100 17 100
100 18 100
100 19 100
100 20 100
100 21 100
Port number
Port speed
Port LEDs
10 100 22 100
11 100 23 100
12 100 24 100
9341EA
Figure C-1.
LED Display for the Model 5625HD Switch Module
206208-A
C-1
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Model 5625HD EtherSpeed Switch Module
Table C-1 describes the operating conditions that cause the LEDs to light on the
Model 5625HD switch module.
Table C-1.
Type
LEDs on the Model 5625HD Switch Module
Label
Color/Status
Meaning
Annunciator 5625HD 10/100Mb/s Amber
Switch Host
The switch is booting.
Green
Off
The switch is running.
The switch module is not receiving
power.
Port Status Numbers 1 to 24
Flashing
Green/Amber Half-duplex/spanning tree is blocked.
Yellow/Amber Full-duplex/spanning tree is blocked.
Port is operational at full-duplex mode.
Yellow
Green
Port is operational at half-duplex
mode.
Amber
Off
Port is disabled by management.
Port is enabled, but no link exists.
Port is operating at 10 Mb/s.
Port is operating at 100 Mb/s.
Port Speed 100
Off
Green
C-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
LEDs
RJ-45 LEDs
In addition to the LEDs shown in Figure C-1, each port’s RJ-45 connector
contains two LEDS. The LEDs show Model 5625HD switch module port status.
The amber RJ-45 LED blinks if a line error is detected. The port has detected one
or more CRC errors, data alignment errors, or frames that are too long.
In half-duplex mode, this blinking may also indicate receive or transmit collisions
on the network, which can happen during normal operation. If these collisions
continuously occur, check the statistics for the port from a management interface
such as the CLI or SpeedView to identify the type of error.
The green RJ-45 LED flashes to indicate that the port is either actively receiving
or transmitting data.
Amber LED blinks if
line error is detected
Green LED blinks
if active
9363FA
Figure C-2.
RJ-45 LEDs for the Model 5625HD Switch Module
206208-A
C-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
Numbers
C
100BASE-T
connecting, 3-8
port description, 1-10
cables
10BASE-T Ethernet UTP crossover, 3-8
Category 5 UTP, B-5
connecting to EtherSpeed ports, 3-8
crossover, 2-2, B-3, B-5
length limits, B-1
10BASE-T
connecting, 3-8
port description, 1-10
802.1d standard, 1-7
802.1Q tags, 1-3
STP, B-6
A
annunciator LED, 3-11
Category 5 UTP, B-5
applications
dedicated port for server, 2-5
desktop switch, 2-7
frame-to-cell converter, 2-10
segment switch, 2-9
chassis, module placement in, 3-2
CLI, 1-7, 4-4
configuration
autonegotiation
features, 1-3
ports, 1-10
ATM uplinks, 2-7
desktop switch, 2-10
frame-to-cell converter, 2-10
guidelines, 2-1
network examples, 2-3
previous, 4-2
B
backbone switch, 2-9
segment switch, 2-9
SpeedView, 1-1
SpeedView predefined, 2-12
backplane
Centillion ATM bus, 3-2
functions, 3-3
structure, 1-9
configuration terminal
protocol setup, 3-10
BayStack switches, 2-10
bridge, replaced by switch, 2-6
congifuration
default, 2-12
connections
problem, 4-4
to servers, 2-5
206208-A
Index-1
Download from Www.Somanuals.com. All Manuals Search And Download.
connectors
10BASE-FL, 3-9
L
LEDs
10BASE-T, 3-8
RJ-45, 1-2, 1-10, B-4
annunciator, C-1
description, C-2
location, 1-10
crossover cable, 2-2
matrix illustration, C-1
RJ-45 connector, C-3
verifying installation, 3-8
crossover cables, 2-2, B-3, B-5
customer support, xviii
D
M
dedicated ports, 2-5
default configuration, 2-12
desktop switch, 2-7, 2-10
MDI connections, 2-2
MDI-X pin assignments, B-4
MIB-I, MIB-II support, 1-7
MLT, 2-11
E
EIA/TIA-T568A cable standard, B-5
mode parameter, 2-12
enterprise network, segment switch in, 2-9
modules
arranging in Model 5000BH/5005BH chassis, 3-2
installing, 3-6
removing and replacing, 3-12
F
factory default configuration, 2-12
features, 1-3
MPOA (multi-protocol over ATM), 1-4
Multi-Link Trunking, 2-11
filtering, 1-8
filters parameter, 2-12
frame-to-cell converter, 2-10
N
network devices, connecting, 2-2
H
network examples
hot-swapping, 1-8
hubs, connecting, 2-2
dedicated port for server, 2-5
desktop switch, 2-7
frame-to-cell converter, 2-10
overview, 1-2
I
segment switch, 2-9
installation
network management features, 1-6
NIC (network interface card), 3-8
modules, 3-6
modules in Model 5000BH/5005BH chassis, 3-2
switch module, 3-6
tools and equipment, 3-5
verifying, 3-8
O
Optivity, 1-6
P
path cost parameter, 2-12
physical configuration, 2-1
Index-2
206208-A
Download from Www.Somanuals.com. All Manuals Search And Download.
pin assignments
Spanning tree group
parameter, 2-12
MDI-X port, B-2, B-4
service port, 3-10
Spanning Tree Protocol
parameter, 2-12
support, 1-7
port
connection problems, 4-4
dedicated, 2-5
MDI, B-2
MDI-X, 2-2, B-2, B-4
priority, 2-12
specifications, technical, A-1
SpeedView
description, 1-6
predefined configurations, 2-12
stackable switches, 2-10
speed, 2-12
STP cable guidelines, B-6
state, 2-12
straight-through cable, 2-2, B-3
support, Nortel Networks, xviii
switching mode parameter, 2-12
product support, xviii
publications
hard copy, xvii
related, xvi
T
technical publications, xvii
technical specifications, A-1
technical support, xviii
R
replacement conditions, 3-11
rfc 1213, 1-7
terminal
RJ-45 connector LEDs, C-3
RJ-45 connectors, 1-2
RS-232 cable, 3-9
communication parameters, 3-9
service port, 3-9
tools and equipment for installation, 3-5
troubleshooting, 3-11, 4-1
S
TTY-compatible terminal, 3-9
sample networks
dedicated port for server, 2-5
desktop switch, 2-7
U
UTP (unshielded twisted pair) cables
Category 5 guidelines, B-5
frame-to-cell converter, 2-10
segment switch, 2-9
segment switch, 2-9
V
server, dedicated port, 2-5
virtual LANs, support for, 1-8
service port
VLANs
connecting a terminal, 3-9
pin assignments, 3-9
terminal attributes, 3-9
description, 1-8
protocol-based, 1-3
shared media and switches, 2-9
slots, placement of modules in, 3-2
SNMP support, 1-7
206208-A
Index-3
Download from Www.Somanuals.com. All Manuals Search And Download.