Newcon Optik Hunting Equipment NC 3 12X50 User Manual

Operation Manual  
NC 3-12x50  
DAYTIME RIFLE SCOPE  
105 Sparks Ave., Toronto, ON M2H 2S5, Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT INFORMATION  
Read prior to activation.  
NC 3-12x50 is the sophisticated optical  
riflescope. To operate it properly, please read this  
manual carefully. Ignoring operation procedures  
described in this manual will void your warranty.  
NEVER disassemble the unit.  
NEVER reverse the polarity of a battery.  
NEVER connect the unit to external power  
sources.  
ALWAYS remove battery when the unit not in  
use for a long period.  
ALWAYS keep the objective lenses covered  
when not in use.  
ALWAYS store the unit in a warm dry place.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Precautions  
NC 3-12x50 is the sophisticated precise optical  
instrument equipped with electronics.  
It should be handled with due care:  
Unit contains fragile components. Avoid impacts,  
dust, moisture and sharp changes of temperature.  
Do not touch the optical surfaces other than for  
cleaning. Doing so may damage the anti-  
reflection coating.  
Clean optical surfaces with professional lens  
cleaning supplies.  
Use only a soft clean cloth to clean the exterior of  
the riflescope.  
Store the unit away from sources of heat, such as  
heating appliances, sunlight or central heating.  
Switch off the unit and remove the battery during  
extended periods of non-operation.  
Do not store the riflescope at temperatures higher  
than 600C (1400F).  
Do not apply excessive force or pressure to the  
lens assembly, movable parts and threaded  
connections.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE OF CONTENTS  
DEVICE APPEARANCE........................................6  
1. BRIEF DESCRIPTION.......................................8  
2. DELIVERY SET.................................................9  
3. TECHNICAL SPECIFICATIONS....................10  
4. TYPE AND SIZE OF THE RETICLE..............11  
5. INSTALLATION ON THE WEAPON ............20  
6. BATTERY INSTALLATION ..........................21  
7. RETICLE ILLUMINATION ............................21  
8. USING THE NC 3-12x50 RIFLESCOPE ........22  
9. ADJUSTMENT ON THE WEAPON...............24  
10. STORAGE AND MAINTENANCE ...............27  
11. TROUBLESHOOTING...................................28  
12. WARRANTY ..................................................29  
13. CUSTOMER SUPPORT .................................30  
14. ACCEPTANCE CERTIFICATE.....................31  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEVICE APPEARANCE  
Figure 1  
For numbering see the next page.  
The manufacturer reserves the right to implement design  
and specification improvements from time to time without  
notice.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Figure. 1  
- Body of the riflescope  
- Objective lens  
- Eyepiece  
1
2
3
4
5
6
7
8
9
- Battery compartment  
- Internal windage/elevation adjustment knobs  
- Reticle brightness adjustment switch  
- Parallax adjustment knob  
- Magnification adjustment ring  
- Objective lens cover  
10 - Zeroing setscrew  
11 - Fixation screws of the elevation adjustment  
12 - Fixation of the windage adjustment  
13 - Optional Hood  
14 - Eyepiece cover  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. BRIEF DESCRIPTION  
NC 3-12x50 is the daytime riflescope with variable  
magnification, which is designed for being used on  
various kinds of weapons.  
The Mil-dot reticle of the riflescope is positioned in  
the focal plane of the eyepiece (second focal plane),  
thus providing permanent size of the reticle  
regardless of the riflescope variable magnification.  
This creates favorable conditions for acquisition of  
small targets at long distances, due to the fact that  
the reticle covers only small portion of the target at  
large magnification.  
The riflescope is equipped with central system  
parallax adjustment, which works for ranges from 50  
meters to infinity.  
The reticle is highlighted with red LED with seven  
modes of brightness.  
The riflescope incorporates windage adjustment (the  
multi-revolving scheme) and elevation (single-  
revolving scheme), allowing to adjust shooting  
ballistics in wide range.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. DELIVERY SET  
Standard delivery set of NC 3-12х50 includes:  
- Device  
- 1 pc.  
- 1 pc.  
- 1 pc.  
- 1 pc.  
- 1 pc.  
- 1 pc.  
- 1 pc.  
- Objective lens cover  
- Eyepiece cover  
- Cleaning cloth  
- Allen key for setting zero  
- Battery CR2032  
- Manual  
Optional accessories:  
- Hood  
- 1 pc.  
- 2 pc.  
- 1 pc.  
- Rings for installation on a weapon  
- Hard transportation case  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. TECHNICAL SPECIFICATIONS  
Magnification, х  
Objective lens diameter, mm  
Field of view, º  
3 to 12  
50  
6.8 to 1.7  
(from 11.9m to  
3m @100m)  
12.5 to 4.1  
+3, -3  
Exit pupil, mm  
Diopter adjustment  
Eye relief distance, mm  
Reticle battery, V  
Battery life, h  
100  
CR 2032 (3 V)  
15 to 100  
Adjustment mechanism, step  
Elevation range  
10mm @100m  
±1.7m @100m  
± 0.6m @100m  
±0.27m @100m  
-50° … +50°  
Up to 98  
Maximum windage range  
Working windage range  
Operational temperature, оС  
Relative humidity, %  
Dimensions (without mount), mm  
Mounting ring diameter, mm  
Weight (without mount), kg  
347x77x77  
30  
0.78  
The manufacturer reserves the right to implement design  
and specification improvements from time to time without  
notice.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. TYPE AND SIZE OF THE RETICLE  
Reticle description.  
The riflescope incorporates black illuminated  
reticle as shown on the Fig. 2.  
Figure 2  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The central part of the reticle represents Mil-Dot  
grid with added additional vertical and horizontal  
markings in made with variable step. Such pattern  
corresponds to the TMR grid. The grid has  
breakdown for a finer step (of 0.2 thousands of a  
distance) on the edges. This is necessary for exact  
estimation of shooting distance for ranges from 500  
to 1000 meters and above. The additional markings  
allow distance measuring more precisely and,  
consequently, improve accuracy of shooting  
comparing with regular Mil-Dot reticles.  
Brightness of a reticle is adjusted by the switch (6).  
Consequent pressing of the switch changes  
brightness from non-illuminated reticle to maximum  
illumination with four different brightness steps.  
The reticle is located in the second focal plane, and  
its sizes do not change with change of the riflescope  
magnification, however, the size of the reticle does  
change relatively to the observation object  
depending on magnification.  
The segments of the reticle (A, B, C, D, E, F, G,  
H) can be described by two equally correct  
methods.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Method 1.  
Reticle segments are described in angular units as  
thousands of a distance or mils (1 mil).  
Note  
1 mil represents the angular measure of a  
distance and constitutes:  
1 mil = 1 t.d. (one thousands of a distance),  
or  
or  
= 10 sm at 100 m of a distance,  
= 3.438*MOA (Minute of Angle).  
The segment E on the Fig.2 = 1 mil (=1 t.d.) is the  
distance between large dots.  
The size of the segments of the reticle in the Table. 2  
are given in mils.  
TABLE 2  
A
B
C
D
E
F
G
H
Size in t.d.  
(or mil)  
10  
0.75  
0.05  
0.4  
1.0  
0.15  
0.5  
0.2  
Method 2.  
Reticle segments are described in centimeters at  
100m distance with 12x magnification.  
The segment E (Fig. 2) equals to 10 cm at 100 m  
distance for 12x magnification.  
The size of the segments of the reticle in the Table. 3  
are given in cm @100m for magnification 12x.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 3  
A
B
C
D
E
F
G
5
H
2
Size in  
cm  
100  
7.5  
0.5  
4.0  
10  
1.5  
@100m  
distance  
The segments of the reticle for other magnification  
settings are given in the Table 4 (all numbers are  
measured in cm @100m).  
TABLE 4  
Magnification, x  
A
B
C
D
E
400  
300  
200  
150  
120  
100  
28.0  
21.0  
14.0  
10.5  
8.4  
2.0  
10.0  
7.50  
5.00  
3.8  
40.0  
30.0  
20.0  
15.0  
12.0  
10.0  
3
4
1.5  
1.00  
0.75  
0.60  
0.50  
6
8
3.0  
10  
12  
7.0  
2.5  
It’s possible to determine segments size for any  
magnification with the formula:  
[specified size at 12x] х 12  
Size of the segment at 100 m = --------------------------------  
(with magnification V)  
Selected magnification V  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Example:  
Let's find size of the segment (E) of the thin cross hair at  
100 m distance with 8 x magnification.  
The specified step at 100 m distance and 12x  
magnification is10cm.  
Now we shall calculate its size at 8x magnification:  
E = (10 х 12): 8 = 15 cm at 100 m.  
The distance to the target also influences the  
corresponding sizes of the reticle.  
Size of the segment = (calculated size of reticle @100m)  
х K,  
where K- adjustment for particular distance and equals  
to:  
= 0.5 – for 50 m distance,  
= 1.0 – for 100 m distance,  
= 2.0 – for 200 m distance,  
= 3.0 – for 300 m distance (etc).  
Example:  
Let's find size of the segment (E) of the thin cross hair at  
300 m distance with 8 x magnification.  
The specified step at 100 m distance and 8x magnification  
is15cm. At 300m it is equal to:  
E=15x(300:100) = 45 cm  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Determining distance to the target (for 12х  
magnification only).  
By using the Mil-dot reticle and knowing the size of  
the target, it is possible to determine distance to the  
target with enough accuracy that is required to  
acquire the target (or make windage adjustment to  
compensate the bullet drop).  
Procedures:  
1) Make sure that the riflescope is set to 12х  
magnification;  
2) Estimate real horizontal (or vertical) size of  
the target, to which you will be determining  
distance;  
3) Look at the cross hair of the riflescope so  
that one dimension of the target is visible  
through the Mil-dot reticle (see Fig. 3),  
4) Count number of divisions in length (or  
height) of the target (the more precise is your  
knowledge of the size of the target, the more  
accurately you can determine distance to the  
target, which is very important for small targets  
located at distances of more than 450m),  
5) Distance can be determined by the following  
formula:  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
L= (H х 1000) / h,  
where  
L – distance to the target, m;  
H – real length (or height) of the target, m;  
h – number of the segments of the reticle that  
cover the chosen dimension of the target.  
Figure 3  
(see also TABLE 6)  
The Figure 3 shows an example of distance  
estimation to a boar, which is 1.5 meters in length.  
Also, it is possible to determine distances to targets  
with size of the target being from 30 cm to 2 m using  
Tables 5 and 6.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 5  
Distance to the target, m  
Real length (or height) of the target, cm  
Number  
of  
30  
40  
50  
60  
70  
80  
90  
segments  
(in mils  
or t.d.)  
1.00  
1.25  
1.50  
1.75  
2.0  
2.5  
3.0  
3.5  
4.0  
4.5  
5.0  
5.5  
6.0  
6.5  
7.0  
7.5  
8.0  
300  
240  
200  
171  
150  
120  
100  
86  
75  
67  
60  
55  
50  
46  
43  
40  
38  
35  
33  
32  
400  
320  
267  
229  
200  
160  
133  
114  
100  
89  
80  
73  
67  
62  
57  
53  
50  
47  
500  
400  
333  
286  
250  
200  
167  
143  
125  
111  
100  
91  
83  
77  
71  
67  
63  
59  
56  
53  
600  
480  
400  
343  
300  
240  
200  
171  
150  
133  
120  
109  
100  
92  
86  
80  
75  
71  
67  
63  
700  
560  
467  
400  
350  
280  
233  
200  
175  
156  
140  
127  
117  
108  
100  
93  
800  
640  
533  
457  
400  
320  
267  
229  
200  
178  
160  
145  
133  
123  
114  
107  
100  
94  
900  
720  
600  
514  
450  
360  
300  
257  
225  
200  
180  
164  
150  
138  
129  
120  
113  
106  
100  
95  
88  
82  
78  
74  
8.5  
9.0  
9.5  
44  
42  
89  
84  
10.0  
30  
40  
50  
60  
70  
80  
90  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 6  
Distance to the target, m  
Real length (or height) of the target, m  
Number  
of  
1.00  
1.25  
1.50  
1.75  
2.00  
segments  
(in mils  
or t.d.)  
2.0  
2.5  
3.0  
3.5  
4.0  
4.5  
5.0  
5.5  
6.0  
6.5  
7.0  
7.5  
8.0  
8.5  
9.0  
500  
400  
333  
286  
250  
222  
200  
182  
167  
154  
143  
133  
125  
118  
111  
105  
100  
625  
500  
417  
357  
313  
278  
250  
227  
208  
192  
179  
167  
156  
147  
139  
132  
125  
750  
600  
500 (*)  
429  
375  
333  
300  
273  
250  
231  
214  
200 (*)  
188  
176  
167  
875  
700  
583  
500  
438  
389  
350  
318  
292  
269  
250  
233  
219  
206  
194  
184  
175  
1000  
800  
667  
571  
500  
444  
400  
364  
333  
308  
286  
267  
250  
235  
222  
211  
200  
9.5  
10.0  
158  
150 (*)  
correspond to the example with the boar on the  
Figure 3  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. INSTALLATION ON THE WEAPON  
Installation of the NC 3-12x50 on the weapon  
includes mounting and gluing of the fixation rings  
(Ø30mm) in accordance with the installation manual  
of the ring manufacturer.  
The Ø30mm fixation rings must be firmly attached  
to the riflescope body with a two-componential  
epoxy glue.  
WARNING:  
Do not over tighten fixation rings. Over tightening  
can lead to deformation of the riflescope, and this  
will prevent parallax adjustment mechanism to  
work correctly.  
If screws of the front fixation rings are tightened  
with excessive force, the parallax adjustment knob  
will rotate with effort. In this case it is necessary to  
loosen screws of the fixation ring to restore the  
normal way of parallax knob rotation.  
It is recommended to allow negative inclination of  
the riflescope towards the rifle barrel in the range  
of 0-0.5 degrees to allow wider range of the  
elevation adjustment. Such precaution will provide  
longer range shooting.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The riflescope NC 3-12х50 can be supplied with  
fixation mounts for exact weapon model or without  
them depending on the particular order.  
6. BATTERY INSTALLATION  
The riflescope operates with one CR2032 battery.  
Be sure that the battery is brand new and is installed  
with correct polarity (“–“sign goes inside the battery  
compartment).  
To install the battery, unscrew the battery  
compartment cover (4, Fig 1), insert the battery  
observing polarity, and screw the cover back.  
7. RETICLE ILLUMINATION  
The reticle illumination is digitally controlled by the  
switch (6, Fig.1). A short pressing of this switch sets  
the reticle to the illumination position, which was set  
the last time when the riflescope was used.  
The reticle illumination is adjusted by pressing and  
depressing the switch. You can choose among seven  
possible illumination levels. If the battery is  
discharged, the reticle will blink being turned on.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The reticle illumination turns off automatically after  
30 minutes from the last pressing of the switch.  
Before turning off, the reticle blinks during several  
seconds. In order to turn the reticle illumination off  
manually, it is necessary to press and hold the switch  
during 2 seconds.  
8. USING THE NC 3-12x50 RIFLESCOPE  
Operating procedure:  
1) Mount the unit on the corresponding landing  
place of the weapon and install the battery;  
2) Open objective and eye protection caps;  
3) Achieve maximum sharpness of the reticle  
image by rotating the eyepiece (3, Fig.1);  
4) Check the riflescope for correct parallax  
adjustment. To do so, chose a target for aiming  
and swing your eye from side to side relatively  
to the eyepiece. If the reticle displaces from the  
aiming point, rotate the knob (7, Fig.1) and  
repeat the action. The riflescope is free from  
parallax, if the center of the reticle is not  
displaced relatively to the target with eye  
swinging;  
5) Rotate magnification adjustment ring (8,  
Fig.1) to achieve the required magnification;  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6) If necessary, turn on the switch (6, Fig.1) to  
get the reticle illuminated. You should see the  
red illuminated outline of the reticle. Switch (6,  
Fig.1) also controls the reticle brightness.  
Riflescope is ready for operation.  
After operation:  
1) Switch off the illumination – by returning  
the switch (6, Fig.1) to OFF position;  
2) Close objective and eyepiece caps;  
3) Remove the riflescope from the weapon if it  
is required by conditions for transportation.  
WARNING:  
If you are store the riflescope for long period of  
time without operation remove the battery from the  
battery compartment to prevent battery leakage.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. ADJUSTMENT ON THE WEAPON  
The riflescope is equipped with tactical multi-  
revolving reticle adjustment mechanism. Screws of  
the adjustment mechanism are terminated with  
knobs (5, Fig.1) with the horizontal and vertical  
scales, which allow precise determining of the clicks  
and turns of the knob(s).  
Adjustment is performed as follows:  
1) Mount the riflescope to the weapon;  
2) Find a target or choose a point of aim;  
3) Lock the weapon on the shooting stand;  
4) Aim the weapon at the target using iron  
sights installed on the weapon (if it is possible).  
At this stage you can use laser boresighting  
riflescope (LBS, to be purchased separately),  
which is inserted into the barrel of the weapon  
and points to the geometrical point of the barrel  
extension:  
5) By rotating the windage/elevation  
adjustment knobs, achieve overlapping of the  
cross hair with the aiming point indicated by  
the iron sight or LBS;  
6) Take the weapon from the stand and remove  
LBS;  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7) Make 3-4 single shoots, carefully and in the  
same manner aiming at the target;  
8) Determine grouping of shots and position of  
mean impact point in accordance with the  
shooting instructions (grouping of shots is  
considered normal if it falls under grouping  
standard for this type of weapon without a  
riflescope);  
Figure 4  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9) Make necessary adjustments, if required,  
according to the pictograms shown on the  
windage/elevation knobs.The step of one click  
as shown on the knobs is 10mm at 100m  
distance.  
10) Execute a control shot and make sure that the  
aiming point of the riflescope coincides with a  
hit point of the bullet (perform adjustments  
once again, if necessary);  
11) The zeroed position of the knobs must be fixed  
(this procedure is called “to set a zero”). In  
order to do so, loosen the three setscrews (11,  
Fig. 4) with the hexagon key on each knob.  
Turn the knob without clicks until the zero  
marking coincides with the marking on the  
riflescope body. Tighten the setscrews with the  
same key;  
12) The setscrew (10, Fig.4) stops rotation of the  
knob on the “-2” or “-4” clicks position  
counting from “0” position of the knob. If you  
adjustment mechanism is not mechanically  
locked at the “minus” position, rotate the  
setscrew (10) clockwise by 4-5 full cycles. If  
the screw rotates too easily, lock it with the  
locking substance or paint.  
The riflescope is ready for use.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. STORAGE AND MAINTENANCE  
Protect the riflescope from direct impacts.  
If there is dirt on optical surfaces, wipe optics with  
clean cloth.  
Do not use corrosive liquids such as Acetone for  
riflescope cleaning (wiping with Alcohol is  
allowed).  
Long-tem storage and transportation of the  
riflescope should be performed in a transportation  
case with objective and eyepiece covers closed for  
protection and without a battery.  
It is allowed to store the riflescope in the dry non-  
maintained premises. The storage temperature must  
not exceed +60 0C.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11. TROUBLESHOOTING  
Unit does not focus.  
Rotate the eyepiece as described above in this  
manual. If the riflescope cannot be focused, wipe  
optical components with a clean optical cloth.  
Illumination of the reticle is not working.  
Make sure the battery is installed correctly and not  
discharged.  
Condensation on the riflescope.  
Use special anti-fogging liquids like the ones for  
eyeglasses during cold weather conditions.  
Boresighting problems.  
Make sure that the riflescope is mounted correctly.  
Make sure that riflescope is securely glued in the  
fixation rings, and that the fixation rings are attached  
to the weapon securely without slack.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. WARRANTY  
NEWCON warrants this product against defects in  
material and workmanship for one year from the date of  
the original purchase. Should your Newcon product prove  
to be defective during this period, please deliver the  
product securely packaged in its original container or an  
equivalent, along with the proof of the original purchase  
date, to your Newcon Dealer.  
Newcon will repair (or at its option replace with the same  
or comparable model), the product or part thereof, which,  
on inspection by Newcon, is found to be defective in  
materials or workmanship.  
What This Warranty Does Not Cover:  
NEWCON is not responsible for warranty service should  
the product fail as a result of improper maintenance,  
misuse, abuse, improper installation, neglect, damage  
caused by disasters such as fire, flooding, lightning,  
improper power supply, or service other than by a  
NEWCON Authorized Service.  
Postage, insurance, and shipping costs incurred while  
presenting your NEWCON product for warranty service  
are your responsibility.  
If shipping from North America, please, include a cheque  
or money order payable to NEWCON OPTIK for the  
amount of $15.00 to cover handling and return shipping.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. CUSTOMER SUPPORT  
Should you experience any difficulties with your  
NEWCON OPTIK product, consult the enclosed manual.  
If the problem remains unresolved, contact our customer  
support department at (416) 663-6963 or toll free at 1-  
877-368-6666. Our operating hours are 9am-5pm,  
Monday - Friday, Eastern Standard Time. At no time  
should equipment be sent back to Newcon without  
following the instructions of our technical support  
department.  
NEWCON OPTIK accepts no responsibility for  
unauthorized returns.  
To locate NEWCON Authorized Dealer call:  
Tel: (416) 663-6963 Fax: (416) 663-9065  
The defective products should be shipped to:  
From the USA only:  
2498 Superior Ave. Cleveland, OH 44114  
From all other countries:  
105 Sparks Ave., Toronto, ON M2H 2S5, CANADA  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14. ACCEPTANCE CERTIFICATE  
Riflescope NC 3-12x50  
The unit meets all technical specifications and has passed  
the quality assurance inspection.  
Production date:________________________  
Unit serial number:  
_________________________________  
Quality Inspector:  
__________________________________  
Quality Assurance Seal  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NEWCON OPTIK  
Printed in Canada  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Miele Oven DG 5070 User Manual
Miele Refrigerator K1801VI User Manual
Milwaukee Power Hammer 0757 20 User Manual
MSi Computer Hardware G31M3 User Manual
MTD Blower F5 F8 User Manual
Murphy Switch L129 Series User Manual
NeumannBerlin Microphone EA 30B User Manual
NHT Speaker System 9993 User Manual
Onkyo Stereo Receiver 29400095 User Manual
Panasonic All in One Printer KX FLB756AL User Manual