Mercury Home Security System SR 10K User Manual

SR-10K  
Mag-Stripe Access System  
Users Guide  
Page 1  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OVERVIEW  
Description  
The SR-10K is a complete stand-alone access controller, using either magnetic-stripe  
cards or cipher (keypad) codes for identifying valid users.  
The Card Reader with Keypad and the Interface Module are the SR-10K system's  
major components. Separating the door control and other interface connections not  
only simplifies the installation, but it greatly improves security by placing the door strike  
relay inside the protected area.  
The SR-10K offers unparalleled versatiltiy in its class. The investment an installer makes  
in learning the SR-10K is greatly rewaded by the number of different applications that  
can be solved by the SR-10K.  
And cerainly not least, unlike other strictly stand-alone access controllers, the SR-10K  
supports expansion to multiple readers at a site.  
Programming  
A Master Card places the SR-10K into programming mode. Commands are entered via  
the keypad on the SR-10K reader. In some cases the entry of user cards may also be  
required. A buzzer and two bicolor LEDs provide immediate feedback to the operator.  
Card Database Options  
The SR-10K supports three different card database modes:  
1 - RANDOM mode, supports up to 100 users (factory default):  
This mode allows the use of any magnetic stripe card with standard 'track-2' encod-  
ing, such as the 'MS-SR10CC25', pre-encoded packs of 25 cards, or cards from  
many other access systems, or even bank cards.  
Cards are added into 'user slots' by reading the card at the time of enrollment.  
Individual or a block of 'user slots' may be deactivated.  
2 - BLOCK mode, supports up to 1,600 users:  
This database mode requires that all cards are encoded as a set. (Block orders are  
typically shipped within a week of the order). Add-on orders can specify an existing  
block number and a continuation point. The activation and deactivation of block  
cards may be done without the cards and may be performed either individually or in  
blocks.  
3 - 'FACILITY CODE' mode, there is no limit to the number of users supported,  
since the SR-10K is not checking for a unique code:  
This mode is useful for low security applications where access cards are already in  
use. The number of leading card digits to check is configured from zero to 9 digits.  
Setting the number of card digits to check to 'none' causes the SR-10K to accept  
any magnetic stripe card as a valid user- also known as the ATM Mode, used to  
accept 'any bank card'.  
An additional setting allows the SR-10K to skip up to 15 card digits before assem-  
bling the facility code. This feature is used in case the facility code does not start at  
the beginning of the card.  
Page 3  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OVERVIEW, continued  
Cipher Codes  
The SR-10K supports up to 10 cipher codes. Each code is one to six digits in length -  
shorter codes are terminated with the '#' key. Cipher codes, like cards, are assigned a  
User Level, and like cards, may cause different output relay action depending on the  
direction of the code entry. See the next two sections for more details.  
User Levels  
Each card and cipher code is assigned a User Level from 1 to 3. The User Level, along  
with the selected Operating Mode, determines the result of the card or cipher entry. For  
example, Level 1 users cannot activate the door relay in some modes unless an input  
sees a closed contact.  
Operating Modes  
The versatility of the SR-10K is based on its ability to configure the function of its inputs  
and relays to suit different applications.  
The action performed on the door strike relay, for example, depends on the direction of  
the card (or cipher code) entry, on the User Level, and possibly on the state of one of the  
inputs. In addition, the color of the upper reader LED may display the status of an exter-  
nal device connected to an input, such as an alarm panel's armed/disarmed indicator.  
An Operating Mode is a collection of these functions intended for a specific application.  
The Operating Modes are described in detail later in this document.  
Multi-Reader Sites  
Up to 16 SR-10K's may be linked via a '2-wire' cable. Configuration, card, and cipher  
code database settings can all be made at just one reader and copied to other SR-  
10K's using simple keypad commands. Modifications can still be made at each reader  
in cases, for example, where the databases are not identical at every reader.  
The data link uses the RS-485 interface standard, allowing the total cable run to extend  
up to 4,000 feet. The devices must be connected in a 'daisy-chain' configuration. Install  
the RS-485 termination jumper, J4, on the first and last units only.  
This unique feature bridges the gap between complex computer-based integrated ac-  
cess systems and the simpler, individually programmed stand-alone access control-  
lers.  
Additional Information  
1. The LED's on the interface board are defined as:  
A = Heartbeat and reader status: Fast flash: normal. Slow flash: Reader  
communication lost.  
B = Flashes when there is activity on the RS-485 communication bus.  
2. Jumper J3: not used.  
Page 4  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Quick Start and Configuration Planning  
Quick Start  
The factory default setting enables the SR-10K to be used immediately, without any  
further programming, using the 10 cards shipped with the unit. The database is set to  
Random Mode, and the cards are enrolled as Level 1 users in slots 01 through 10.  
Additional cards are enrolled using Command 10, and Cipher codes may be added  
using Command 15. Command 32 sets the door strike relay pulse time.  
Configuration Planning  
The most important selections are the Card Database Mode and the Operating Mode.  
Card Database Mode Selection (Command 93)  
The 'Random' Database Mode offers great versatility because it allows the use of just  
about any magnetic stripe card. Leave the SR-10K in this mode if the number of users  
will not exceed 100.  
On the other hand, select the 'Block' Card Database Mode right away if the number of  
users may exceed 100, because changing database modes deletes all current entries.  
Operating Mode Selection (Command 95)  
Select the operating mode best suited to the particular site by evaluating the User  
Level functions, the input and auxiliary output functions of each available operating  
mode. The selected operating mode determines the installation wiring details and User  
Level assignment.  
Lost Master Card  
Follow the steps outlined below to set a new Master Card in case the current Master  
Card is lost:  
- remove power from the SR-10K  
- install the jumper in position 8  
- apply power for a few seconds, then remove it  
- remove the jumper from position 8  
- apply power to the SR-10K: the old Master Card has been erased!  
- add the Master Card using Command 91  
(With no valid Master Card, the SR-10K remains in the Programming Mode with the  
lower LED set to amber, until a Master Card is set. In fact, only Command 91 is  
accepted until the new Master Card is set.)  
Interpreting the LED and Buzzer Indicators  
Normal operation - the upper LED is ON steady red or green:  
The lower LED flashes green briefly following the entry of a valid card or ciper code. A  
red flash along with three short beeps indicate an invalid entry attempt.  
Programming mode - the lower LED is ON steady green (amber if no Master Card)  
The upper LED is OFF if the SR-10K is ready for a new command (wait for '*' key)  
The upper LED flashes red while waiting for keypad data entry, and is flashing green  
while waiting for card entry.  
A single beep echoes a key entry, a double beep indicates the completion of a 'field'  
(each line on the command spec section is a field). Three beeps indicate an error  
condition. A long beep indicates proper completion of a command.  
Page 5  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SR-10K Programming Guide  
The COMMAND ENTRY MODE is selected by passing a valid MASTER card through the reader.  
The intergral keypad allows direct data entry on the SR-10K.  
The "*" key is used to start a new command entry. The '#' key terminates field entry. For example,  
selecting user slot 3 for the the 4-digit user slot entry in Command 20 can be entered as 4 digits:  
'0','0','0','3', or it may be entered as '3', '#'.  
A single short beep indicates the acceptance of a digit, a double beep indicates the acceptance of  
a field. Three short beeps indicate that the command aborted due to an error. One long beep  
indicates succesful completion.  
RANDOM and Facility Code Database Mode Commands (Commands 10 through 13)  
Use these commands to manage the card holders if the RANDOM database mode was selected  
Command 93 set to mode "0" - this mode is the facory default.  
Command 10 - Add card(s)  
* 1 0  
1-3  
- select Command 10  
- select the user level: 1, 2, or 3  
0-9  
0-9  
- select the user number: 00 to 99  
- read the card to be added in that slot  
- additional cards will be added into successive slots )  
- any other action quits the "add loop"  
user card  
( user card  
* 0-9  
#
Command 11 - Delete a card, using the user slot  
* 1 1  
0-9 0-9  
- select Command 11  
- select the user number: 00 to 99  
Command 12 - Delete a card, using the card  
* 1 2  
- select Command 12  
user card  
- read the card to be deleted from that slot  
Command 13 - Delete a range of cards  
* 1 3  
- select Command 13  
0-9  
0-9  
0-9  
0-9  
- select the first user number to delete: 00 to 99  
- select the last user number to delete: 00 to 99  
Page 6  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CIPHER CODES Related Commands (Commands 15 through 17)  
Up to 10 cipher codes may be defined (user slots 0 through 9). Each cipher code may be from 1 to  
6 digits long. Cipher codes shorter than 6 digits are terminated with the "#" key. Just like cards can  
produce different results when read "upward", cipher codes can be entered in the "reverse" direction.  
For example, cipher code "123" entered as "3", "2", "1", "#" will produce the action specified for  
"reverse" entry of a user having the User Level assigned to cipher code "123".  
Command 15 - Add Cipher Code(s)  
* 1 5  
- select Command 15  
1-3  
- select the user level: 1, 2, or 3  
0-9  
- select the user number: 0 to 9  
0-9 ( 0-9 ) #  
- enter a 1 to 6 digit cipher code, end with '#'  
- additional codes will be added into successive slots )  
- any other action quits the 'add loop'  
( 0-9, 0-9  
#
* #  
Command 16 - Delete a cipher code  
* 1 6  
0-9  
- select Command 16  
- select the user number to delete: 0 to 9  
Command 17 - Delete a range of cipher codes  
* 1 7  
0-9  
- select Command 17  
- select the first user number to delete: 0 to 9  
- select the last user number to delete: 0 to 9  
0-9  
BLOCK Database Mode Commands (Commands 20 through 23)  
Use these commands to manage the card holders if the BLOCK database mode was selected  
(Command 93 set to mode "1"). The block number is set by Command 94.  
Command 20 - Add a card (activate a user)  
* 2 0  
1-3  
- select Command 20  
- select the user level (1, 2, or 3)  
- enter the user slot to activate (0000 through 1599)  
0-1  
0-9  
0-9  
0-9  
Command 21 - Delete a card (deactivate a user)  
* 2 1  
0-1 0-9  
- select Command 21  
0-9 0-9  
- enter the user slot to deactivate (0000 through 1599)  
Command 22 - Add a range of cards (block activate)  
* 2 2  
1-3  
- select Command 22  
- select the user level (1-3)  
0-1  
0-1  
0-9  
0-9  
0-9 0-9  
0-9 0-9  
- enter the first user slot to activate (0000 through 1599)  
- enter the last user slot to activate (0000 through 1599)  
Command 23 - Delete a range of cards (block deactivate)  
* 2 3  
- select Command 23  
0-1 0-9  
0-1 0-9  
0-9  
0-9  
0-9  
0-9  
- enter the first user slot to delete (0000 through 1599)  
- enter the last user slot to delete (0000 through 1599)  
Page 7  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Configuration Settings (Commands 31through 34)  
Command 31 - Set the Door Held Open Time  
* 3 1  
0-9 0-9  
Command 32 - Set the Door Strike Relay Pulse Time (Output K1)  
- select Command 31 (from door opening to held open alarm)  
- select the held open time: 00 to 99 seconds  
* 3 2  
0-9 0-9  
- select Command 32  
- select the strike pulse time: 00 to 99 seconds (+1/2 second)  
Command 33 - Set the Auxiliary Relay Pulse Time (Output K2)  
* 3 3  
0-9 0-9  
- select Command 33  
- select the pulse time for Output K2: 00 to 99 seconds (+1/2 second)  
Command 34 - Set the Auxiliary Relay's Pulse Time (Output K2)  
* 3 4  
1 or 2  
- select Command 34  
- select the pulse type: 1 for normal, 2 for intermittent output  
Configuration and Database Copy Commands (Commands 41through 44)  
The following commands allow the configuration and database to be copied from one SR-10K to  
another SR-10K. These commands transfer the selected database elements from the SR-10K where  
the command is being entered to the SR-10K whose address is specified in the command.  
The SR-10K addresses are set by installing the jumper pattern for the desired address on the Inter-  
face Module as shown on the installation diagram.  
The color of the upper LED is set to flashing amber for the duration of the the data transfer. Periodic  
short beeps are used by longer transfers to indicate "transfer in progress". The transfer of the entire  
"block mode" card database (1,600 users) may take up to 1 minute.  
The completion of a succesful transfer is indicated with the "long-beep". A transfer error condition is  
signalled with three short beeps along with a red flash on the upper LED. A transfer error is caused  
by either incorrect wiring, or by incorrect jumper settings. Notice: the transfer commands are not  
'broadcast'; each SR10K must be set to a unique address 0 to 15.  
Command 41 - Copy the Configuration settings only - no card or cipher databases  
* 4 1  
0-9 0-9  
- select Command 41 (copies seetings enterd with commands 31-34, and 91-95)  
- select the address of the SR-10K to copy the data to - 00 to 15  
Command 42 - Copy the Cipher Database only  
* 4 2  
0-9 0-9  
Command 43 - Copy the Card Database only  
* 4 3  
0-9 0-9  
Command 44 - Copy ALL: Configuration Settings, Card and Cipher databases  
- select Command 42 - copies cipher users 0 through 9  
- select the address of the SR-10K to copy the data to - 00 to 15  
- select Command 43 - copies users 00 through 99, or through 1599  
- select the address of the SR-10K to copy the data to - 00 to 15  
* 4 4  
- select Command 44 - combines Commands 41, 42, and 43  
- select the address of the SR-10K to copy the data to - 00 to 15  
0-9  
0-9  
Page 8  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Configuration Settings (Commands 91through 95)  
Command 91 - Set a New MASTER Card  
* 9 1  
1 or 2  
- select Command 91  
- select which Master Card to change: 1 or 2  
- read the card to set as the new Master Card  
new card  
Usage notes:  
1 - The second Master Card slot is provided for administrative convenience in cases where the  
owner does not wish to maintain the user database: The owner may retain one Master Card and  
allow the installer to enroll his card as Master Card 2, thereby letting the installer update the  
configuration without having to get the owner's Master Card.  
2 - Multiple SR-10K's may be set to the same Master Card  
Command 92 - Delete MASTER Card 2  
* 9 2  
- select Command 92: deletes Master Card 2  
Command 93 - Set the Database Mode  
* 9 3  
- select Command 93  
0, 1, 2 or 3  
- select the database mode: 0 = Random, 1 = Block, 2 = Facility Code,  
3 = Facility Code with Offset (Skip [n] digits)  
( 0 to 9  
- only if Facility Code modes: number of Facility Code digits to check  
)
(( 0-9 0-9  
- only if Facility Code with Offset: number of digits to skip - 00 to 15 ok  
))  
Usage notes:  
1 - Changing the card Database Mode clears the card database.  
2 - Commands 10 through 13 are used with the Random and Faciltiy Code Database Modes  
3 - Commands 20 through 23 are used with the Block Database Mode  
4 - The Block Number (Command 94) must be set for Block Database Mode operation.  
5 - In Facility Code Database Mode, the digit count specifies the the number of card digits to read  
and verify. For example, setting the count to '3', the SR-10K uses only the first 3 digits on the  
card. Further, setting the count to '0', the SR-10K will accept any properly encoded card,  
regardless of the actual data on the card - this configuration is also called the 'ATM Mode'.  
In the 'ATM Mode', at least one card must be enrolled in the database. Use  
command 10 to enroll a card.  
6 - In Facility Code Database Mode, one card must be enrolled for each 'facility code' that is to be  
accepted. The cards are enrolled using Command 10.  
Command 94 - Set the Block Number  
* 9 4  
- select Command 94 - required to set if Block Database Mode is used  
- enter any user card from the current block  
any user card  
Command 95 - Set the Operating Mode  
* 9 5  
- select Command 95: determines input/output and user level functions  
0-9  
0-9  
- select the Operating Mode: 01 through 06 (see manual for details)  
01 - Basic access control with door alarm monitoring  
02 - ...like mode 01, denies User Level 1 based on input contact  
03 - Access control with pulsed auxiliary output control (alarm panel)  
04 - ...like mode 03, restricts User Level 1 based on input contact  
05 - Access control with toggled auxiliary output control  
06 - Two-door control  
07 - "Door Buzzer" option: *, or #, or REX pulses Output K2  
08 - "Dual Output" toggle with restricted access of Level 1 users  
Page 9  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 01:  
Access Control with Door Monitoring  
Description  
Access Control with Door Monitoring provides for basic access control and door use  
annunciation.  
A downward read of all valid User Cards pulse Output K1, the strike control relay.  
The upward read of a Level 2 card toggles the strike control relay, in effect performing a  
lock/unlock function. The upward read of a Level 1 card will release an unlocked condi-  
tion.  
Output K2 is pulsed to annunciate improper door use, such as  
a) Forced Open condition, which occurs if the door opening was not preceded by the use  
of a valid card or an exit request, or  
b) Held Open condition, which occurs if the door is kept open longer than the preset open  
time.  
User Level Specifications  
User Level 1  
A downward read will pulse Output K1 (no effect if the door is unlocked).  
A upward read will turn off Output K1, ending an unlocked condition.  
User Level 2 (and 3)  
A downward read will pulse Output K1 (no effect if the door is unlocked).  
A upward read will toggle the state of Output K1, locking or unlocking the door.  
Configuration  
Inputassignments:  
Input I1 is connected to a door contact: closed contact signifies a closed door.  
Input I2 is connected to a “request to exit” button. Closing the contact initiates the  
request.  
Upper LED assignment:  
The upper LED follows Output K1, the strike control output. Normally RED, the LED  
turns GREEN when the door strike is energized (either the timed, or unlocked).  
Notes  
This mode is the factory set default. It represents the "classic" access controller model  
due to the implementation of the door contact and the request to exit sensors and the door  
alarm annunciator relay.  
The 10 cards included in the original shipment are enrolled as Level 1 users. Be aware,  
that if they are modified or any subsequent cards are added as Level 2 users, an up-  
ward read will unlock the door - requiring another upward read (by any user Level) to  
release the locked condition. Add Level 2 users only if the lock/unlock function is desired.  
Page 10  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 02:  
Restricted Access Control with Door Monitoring  
Description  
Restricted Access Control with Door Monitoring restricts Level 1 user access based on the  
status of Input I2 and provides door use annunciation on Output K2.  
Level1cardsareacceptedonlyiftheInputI2seesaclosedcontact. Level2or3cardsarenot  
dependentonInputI2.  
A downward read of all valid User Cards pulse Output K1, the strike control relay.  
The upward read of a Level 2 card toggles the strike control relay, K1, in effect performing a  
lock/unlock function. The upward read of a Level 1 card will release an unlocked condi-  
tion.  
Output K2 is pulsed to annunciate improper door use, such as  
a) Forced Open condition, which occurs if the door opening was not preceded by the use  
of a valid card or an exit request, or  
b) Held Open condition, which occurs if the door is kept open longer than the preset open  
time.  
User Level Specifications  
User Level 1  
A downward read will pulse Output K1 only if Input I2 is closed.  
A upward read ends an unlocked condition, regardless of the status of Input I2.  
User Level 2 (and 3)  
A downward read will pulse Output K1 (no effect if the door is unlocked).  
A upward read will toggle the state of Output K1, locking or unlocking the door.  
Configuration  
Inputassignments:  
Input I1 is connected to a door contact: closed contact signifies a closed door  
InputI2isconnectedtotheaccesscontrolcontrolcontact,suchasanexternaltimer.User  
Level 1 cards are accepted only when a closed contact is presented to this input.  
Upper LED assignment:  
The upper LED follows Input I2, the Access Control Input:  
Open Contact is displayed as RED  
Closed Contact is displayed as GREEN.  
Notes  
This mode is very similar to Operating Mode 1. The same caution should be observed  
regarding the ability to permanently unlock the door:  
The 10 cards included in the original shipment are enrolled as Level 1 users. Be aware,  
that if they are modified or any subsequent cards are added as Level 2 users, an up-  
ward read will unlock the door - requiring another upward read (by any user Level) to  
release the locked condition. Add Level 2 users only if the lock/unlock function is desired.  
Consider using Operating Mode 4 or 5 if restricted access is required, but the  
unlock function is not.  
Page 11  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 03:  
Access Control and Alarm Panel Control  
Description  
The Access Control and Alarm Panel Control configuration provides for basic access  
control and gives some users the ability to send a pulse to arm and disarm alarm panels.  
Both a downward and an upward read of all User Cards pulse Output K1, the strike control  
relay, to allow entry. In addition, the upward read of a Level 2 card pulses Output K2,  
allowing the momentary closure to simulate a key-switch input to an alarm panel.  
User Level Specifications  
User Level 1  
Both downward and upward read will pulse Output K1.  
User Level 2 (and 3)  
A downward read will pulse Output K1  
An upward read will pulse both Output K1 and Output K2.  
Configuration  
Inputassignments:  
Input I1 is connected to the armed/disarmed status output from the alarm panel.  
Input I2 is connected to a “request to exit” button. Closing the contact initiates the  
request.  
Upper LED assignment:  
The upper LED follows Input I1, displaying the status of the alarm panel:  
Open Contact is displayed as RED  
Closed Contact is displayed as GREEN  
Page 12  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 04:  
Restricted Access Control and Alarm Panel Control  
Description  
Restricted Access Control and Alarm Panel Control provides restricts Level 1 user access  
based on the status of Input I2 and it gives some users the ability to arm/disarm alarm panels.  
Level 1 users are accepted only if Input I2 sees a closed contact. Level 2 or 3 users are not  
dependentonInputI2.  
Bothadownwardandanupwardreadofallvaliduserspulsethestrikecontrolrelay.Inaddition,  
theupwardreadofaLevel2cardpulsesOutputK2,allowingthemomentaryclosuretosimulate  
a key-switch input to an alarm panel.  
User Level Specifications  
UserLevel1  
CardshavingthisUserLevelarerejectedifthecontactonInputI2isopen.IfthecontactonInput  
I2 is closed:  
Both downward and upward read will pulse Output K1.  
User Level 2 (and 3)  
A downward read will pulse Output K1, allowing entry.  
An upward read will pulse both Output K1 and Output K2.  
Configuration  
Inputassignments:  
Input I1 is connected to the armed/disarmed status output from the alarm panel.  
Input I2 is connect to an external timer and functions as the access control input. User  
Level 1 users are valid only when a closed contact is presented to this input.  
Upper LED assignment:  
The upper LED follows Input I1, displaying the status of the alarm panel:  
Open Contact is displayed as RED  
Closed Contact is displayed as GREEN  
Page 13  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 05:  
"Supervisor" Restricted Access Control  
Description  
ThismodeallowsLevel2cardstotoggleOutputK2,which,connectedbacktoInputI2,restricts  
Level 1 users. In this mode, Level 1 cards are accepted only if Input I2 sees a closed contact.  
User Level Specifications  
UserLevel1  
CardshavingthisUserLevelarerejectedifthecontactonInputI2isopen.IfthecontactonInput  
I2 is closed:  
A downward read will pulse Output K1.  
User Level 2 (and 3)  
A downward read will pulse Output K1, allowing entry.  
An upward read will toggle Output K2.  
Configuration  
Inputassignments:  
Input I1 is connected to the request to exit (REX) contact.  
Input I2 is connect to Output K2 and functions as the access control input. User Level  
1 users are valid only when a closed contact is presented to this input.  
UpperLEDassignment:  
The upper LED follows Input I2, displaying the status of the access control input:  
Open Contact is displayed as RED  
Closed Contact is displayed as GREEN  
Operating Mode 06:  
"Two-Door" Access Control  
Description  
ThismodeallowsUserLevel1cardstoactivateOutputK1,UserLevel2cardstoactivateOutput  
K2, and User Level 3 cards to activate either Output K1 or Output K2.  
User Level Specifications  
UserLevel1  
Both downward and upward read will pulse Output K1.  
UserLevel2  
Both downward and upward read will pulse Output K2.  
UserLevel3  
Downward read will pulse Output K1.  
Upward read will pulse Output K2.  
Configuration  
Inputassignments:  
The inputs are not used in this mode.  
Upper LED assignment:  
Output K1 off is displayed as RED,  
Output K1 on is displayed as GREEN  
Page 14  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Mode 07:  
Access Control with Door Buzzer Control  
Description  
Access Control with Door Bell Control operates just like Mode 1, with an additional feature  
for using Output K2 for annunciation.  
This mode was created for applications where Output K2 is configured to drive a door bell/  
buzzer. A valid Level 1 user or a Request to Exit input activation will pulse Output K2 for  
about one second, creating the "buzz-in" sound.  
Pressing the "*" or the "#" keys will act like a door bell. Pressing either "*" or "#" keys will  
cause a double pulse on Output K2, creating a sound pattern easily distinguished from the  
normal access or exit cycle.  
Access by Level 2 users does not affect Output K2 - creating a "silent" entry.  
Refer to Mode 1 description for full operational definition.  
Operating Mode 08:  
Output Toggle on Valid Access  
Description  
This mode is intended for applications where the outputs need to be toggled, instead of the  
standard momentary pulse operation. Both outputs are toggled.  
Level 1 users alter the outputs only if Input I2 sees a closed contact.  
The upper LED reflects the state of the outputs.  
User Level Specifications  
User Level 1  
A read in either direction will toggle Output K1 and Output K2 only if Input I2 is closed.  
(The outputs are not affected if Input I2 is open)  
User Level 2 (and 3)  
A read in either direction will toggle Output K1 and Output K2, regardless of the state of  
InputI2.  
Configuration  
Input assignments:  
Input I1 is not used.  
InputI2isconnectedtotheaccesscontrolcontrolcontact,suchasanexternaltimer.User  
Level 1 cards are accepted only when a closed contact is presented to this input.  
Upper LED assignment:  
The upper LED follows Output K1 (and Output K2):  
Deenergized output is displayed as RED  
Energized output is displayed as GREEN.  
Page 15  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Find a suitable location to anchor the reader mounting bracket. The mounting of the reader does not  
requireajunctionbox. However, rigidconduitisrequiredforoutdoorapplication. Asinglegangjunction  
box may used to provide transition to rigid conduit. If a single gang junction box is used, a wall plate  
(optional)maybeusedtocoverthejunctionbox.Thereaderisthensecuredtothemountingbracketusing  
a screw. Refer to figures for reader dimensions and typical junction box usage.  
Connect door hardware/power according to the configuration selected. Wires of 22AWG or larger are  
recommended for field wiring. See local electrical code.  
Coat reader connector with the silicone grease supplied to seal off moisture for outdoor mounting.  
To avoid having ESD (electrostatic discharge) interfering with the operation of the reader, the reader  
casing shall be grounded. This can be accomplished be tying the mounting bracket to earth ground  
locally (e.g. grounded conduit).  
Reader DIP switch setting:  
4
3
2
1
Factory Preset.  
OFF OFF OFF ON  
Relay Contact Protection/Noise Suppression  
Load switching can cause contact transfer, welding, and abnormal wear, which can cause premature  
contact failure. The switching of an inductive load (strike) can also cause EMI (electromagnetic  
interference). Toprolongcontactlifeandincreasetotalsystemreliability,contactprotectioncircuitmust  
be used. The following two circuits are recommended. For DC application, use a diode circuit; for AC  
application, use a MOV (metal oxide varistor) circuit. Locate the protection circuit as close to the load  
as possible, as the effectiveness of the circuit will decrease if it is located to far away. As a guideline,  
the distance should be within 12 inches (30 cm). Mag Locks may have internal noise suppression,  
please refer to the manufactures documentation. Mag Locks should be wired to Output K1 normally  
closed(NC)terminal.  
DIODE SELECTION:  
+ −  
DIODE CURRENT RATING > 1X STRIKE CURRENT  
DIODE BREAK DOWN VOLTAGE : 4X STRIKE VOLTAGE  
DIODE 1N4001 (50V/1A) TYPICAL  
AC STRIKE  
AC  
MOV SELECTION:  
VOLTAGE RATING > Vac RMS  
FOR 24Vac STRIKE, PANASONIC ERZ-C07DK470  
Page 16  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
The SR-10K readers are designed to provide continuous service with minimal routine maintenance.  
However, contaminants (such as magnetic oxides from badges and dirt) tend to accumulate on the  
read head. Without regular cleaning, these contaminants will shorten the read head life and increase  
the probability of card read error. A maintenance schedule should be developed base on the card  
reader environment (dirty or clean) and the usage frequency (light traffic or heavy traffic). Extreme  
case may require daily cleaning.  
Head cleaning may be done by using disposable, pre-saturated magnetic head cleaning card. These  
cards are readily obtainable from a number of sources (e.g. Clean Team Co. 800-888-8830,  
4452,www.systemid.com).  
The reader exterior surface is covered with high strength polymer and polyester membrane. It may be  
cleaned with a soft cloth and mild detergent if required.  
Specification:  
The reader/Interface are for use in low voltage, class 2 circuits only.  
Electrical:  
Voltage -  
Current -  
12 Vdc (10.2 to 13.8 Vdc)  
200mA  
Relay contacts- K1, 5A@30Vdc; K2, 1A@30Vdc  
Distance between reader/interface - 500' (152m) max., 22AWG  
RS-485 Comm. Cable - 4,000' (1,219m) max. 24AWG, 120 ohm.  
Mechanical:  
Reader:  
Dimension -  
Weight -  
1.95" (50mm)W x 1.30" (33mm)H x 5.50" (140mm)L  
10 oz. (284 g) nominal  
Interface:  
Dimension -  
Weight -  
3.25" (83mm)W x 2.9" (74mm)L x 1.4" (36mm)H  
4 oz. (120 g) nominal  
Environmental:  
Temperature: -55 to +85 degrees C, storage  
-40 to +75 degrees C, operating  
Humidity:  
Reader- 100% RHNC; Interface- 95% RHNC  
WARRANTY  
Mercury Security Corporation warrants that the product is free from defects in material and workmanship under  
normal use and service for two years from factory shipment. Mercury Security Corporation assumes no  
responsibility for products damaged by improper handling or installation. This warranty is limited to the repair  
or replacement of the defective unit.  
There is no expressed warranties other than set forth herein. Mercury Security Corporation does not make,  
intends, nor does it authorize any agent or representative to make any other warranties, implied warranties, and  
expressly excludes and disclaims all implied warranties of merchantability of fitness for a particular purpose.  
Returned units are repaired or replaced from a stock of reconditioned units. Returns must be accompanied  
by a return authorization number obtained form customer service, a purchase order and prepaid postage.  
LIABILITY  
The card readers should only be used to control exits from areas where an alternate method for exit is available.  
This product is not intended for, nor is rated for operation in life-critical control applications. Mercury Security  
Corporation is not liable under any circumstances for loss or damage caused by or partially caused by the  
misapplication or malfunction of the product. Mercury Security Corporation's liability does not extend beyond  
the purchase price of the product.  
Page 17  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 [36]  
1.3 [33]  
2 X Ø0.18 [4.5]  
HOLES  
2.0 [50]  
3.25 [83]  
Reader and Interface Dimensions  
Reader to Interface Connection:  
Connect the Reader to the Interface  
Module using the straight 6-conductor  
modular cable. DO NOT use cross-  
over cable. Maximum distance  
betweenreaderandinterfaceis500  
feet using 22AWG wires.  
6-COND.STRAIGHT  
J2 Jumpers  
Strike  
JUMPERSETTING  
NC  
C
NO  
NO  
Forced Open,  
NC  
Held Open  
C
Alarm Buzzer  
+
12V  
GND  
I2  
Exit Request  
Door Contact  
I2  
I1  
I1  
Typical Wiring Configuration  
Communication Wiring: Maximum total cable length - 4,000 ft [1,200 m], 24 AWG  
TO ADDITIONAL  
SR−10K  
SR−10K  
SR−10K  
PRINTER INTERFACE  
(DISCONTINUED)  
Set each interface to unique address. Install RS-485 termination jumper, J4, on the first and last units only.  
Page 18  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Addendum - Revision C  
This revision changed the door module to accommodate screw mounting instead of using snap track. The new  
module dimension is 4.25 x 2.75 inches.  
Connection to the card reader is also changed from modular jack to a screw terminals for more convenient  
termination.  
4.25 [108.0]  
0.20 [5.1]  
3.85 [97.8]  
NC  
C
GND (BLK)  
BZR (ORG)  
LED (BRN)  
CLK (WHT)  
DAT (GRN)  
GND  
BZR  
NO  
NO  
NC  
LED  
CLK/D1  
DAT/D0  
+12V  
12V (RED)  
C
+12V  
G
TR+  
TR-  
SG  
PIN 1  
I2  
I2  
I1  
I1  
J3  
B
A
Page 19  
Doc. 10107-0007 Rev 1.04  
Mercury Security Corporation, © 2005  
SR-10K  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Kustom Stereo Amplifier 16R User Manual
Lantronix Switch SLSLP400PS201 User Manual
Lenovo Computer Monitor 7065 User Manual
Linear Vacuum Cleaner V222 User Manual
Magnasonic Portable DVD Player DVD810 2 User Manual
Magnavox VCR MVR650 User Manual
Melissa Light Therapy Device 637 001 User Manual
Melissa Styling Iron 235 005 User Manual
Microsoft Video Game Controller X08 78482 User Manual
Midland Radio Two Way Radio F 10 User Manual