ECHNICAL INFORMATION  
T
PRODUCT  
P 1/ 8  
UB1102, UB1103  
Blower  
Model No.  
Description  
L
H
CONCEPT AND MAIN APPLICATIONS  
Models UB1102, UB1103 Blowers are successors of UB1100, UB1101.  
Their output air volume is 4.1m³/min. over the predecessors 2.8m³/min.  
The other features are as follows:  
W
Ergonomic designed handle with elastomer for more comfortable  
and controlled operation  
Dimensions: mm (")  
Self-standing design enables stationary use, easy storage and upside-down  
standing  
Length (L)  
479 (18-7/8)  
The specification difference between UB1102 and UB1103 is;  
UB1102: Single speed  
UB1103: Variable speed control by dial and trigger  
Width (W)  
Height (H)  
185 (7-1/4)  
178 (7)  
Specification  
Continuous Rating (W)  
Voltage (V)  
Current (A)  
Cycle (Hz)  
Max. Output (W)  
Input  
600  
---  
Output  
---  
---  
110  
120  
220  
230  
240  
5.7  
6.8  
2.9  
2.8  
2.7  
50/60  
50/60  
50/60  
50/60  
50/60  
---  
---  
---  
---  
---  
600  
600  
600  
---  
---  
---  
Model No.  
UB1102  
16,000  
4.1  
UB1103  
No load speed: min.ˉ¹=rpm  
Max. air volume*1: m³/min.  
Max. sealed suction: kPa  
Variable speed control  
0 - 16,000  
0 - 4.1  
0 - 5.7  
Yes  
5.7  
No  
Protection against electric shock  
Power supply cord: m (ft)  
Double insulation  
Australia: 0.5 (1.64), Others: 2.5 (8.2)  
Weight according to  
EPTA-Procedure 01/2003*2: kg (lbs)  
2.0 (4.3)  
*1 Without Nozzle, Joint  
*2 With Nozzle, Joint  
Standard equipment  
Nozzle .....................................1  
Joint .........................................1  
Dust bag (capacity of 2L) .......1 (for some countries)  
Note: The standard equipment for the tool shown above may vary by country.  
Optional accessories  
Dust bag assembly  
Nozzle assembly  
Flexible hose set  
Anchor nozzle set (for vacuum function only)  
Bending long nozzle set  
Long nozzle assembly  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 3/ 8  
Repair  
[3] DISASSEMBLY/ASSEMBLY  
[3] -2. Fan Section  
DISASSEMBLING  
Disassemble Fan 110 as drawn in Fig. 2.  
Fig. 2  
Nozzle  
1. Remove Nozzle.  
2. Remove Set plate by prying it off with  
a small slotted screwdriver.  
Set plate  
Fan cover  
4. Remove M5-8 Hex nut by turning it  
3. Unscrew five 4x18 Tapping screws  
and remove Fan cover.  
counterclockwise with an impact driver while  
holding Fan 110 firmly with a gloved hand.  
5. Remove Flat washer 5, Fan 110 and Flat washer 8.  
Fan cover  
M5-8 Hex nut  
Flat washer 5  
Fan 110  
Flat washer 8  
ASSEMBLING  
Assemble Fan Section by reversing the disassembly procedure. Refer to Fig. 2.  
Note: Align the hole on Set plate with the protrusion on Fan cover, and insert Set plate by hand, then push it  
with a small screwdriver until it stops.  
Refer to the drawing on the top right in Fig. 2.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 4/ 8  
Repair  
[3] DISASSEMBLY/ASSEMBLY  
[3] -3. Motor Section  
DISASSEMBLING  
(1) Remove Carbon brush as drawn in Fig. 3.  
Fig. 3  
Carbon brush  
(2) Disassemble Fan section as drawn in Fig. 2.  
(3) Disassemble Armature as drawn in Fig. 4.  
Fig. 4  
1. Unscrew four 4x35 Tapping  
screws and disassemble Fan  
housing complete.  
2. Remove Flat washer 8 from  
Armature shaft.  
3. Remove Armature from  
Motor housing.  
Flat washer 8  
Armature  
Fan housing  
complete  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 5/ 8  
Repair  
[3] DISASSEMBLY/ASSEMBLY  
[3] -3. Motor Section (cont.)  
DISASSEMBLING  
(4) Disassemble Field as drawn in Fig. 5.  
Fig. 5  
2. Disconnect Field lead wires from Switch.  
1. Unscrew four 4x18 Tapping screws and remove Handle  
cover.  
Switch  
Handle cover  
Field lead wire  
3. Disconnect Ring terminals from Brush holders  
with a Slotted screwdriver.  
4. Unscrew two 5x40 Tapping screws and remove  
Field from Motor housing.  
Field  
Ring terminal  
Note:  
Tapping the edge of Motor housing  
with a plastic hammer enables Field  
to be removed easily.  
Field  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 6/ 8  
Repair  
[3] DISASSEMBLY/ASSEMBLY  
[3] -3. Motor Section (cont.)  
ASSEMBLING  
(1) Assemble Field to Motor housing. Refer to the drawing on the middle right in Fig. 5.  
Also see Fig. D-2 about the wiring of Field lead wires.  
Note: Using 1R063 enables Field to be assembled easily than by hand. See Fig. 6.  
Fig. 6  
Field  
1R063  
(2) Connect Ring terminal to Brush holder using 1R370. See Fig. 7  
.
Fig. 7  
1R370  
Ring terminal  
(3) Connect field lead wires to Switch and mount Handle cover to Motor housing with four 4x18 Tapping screws.  
Refer to the drawings on the top left and right in Fig. 5.  
(4) Insert Armature into Motor housing. Refer to the drawing on the right in Fig. 4.  
(5) Mount Flat washer 8 to the drive end of Armature's shaft. Refer to the drawing on the center in Fig. 4.  
(6) Assemble Fan housing complete with four 4x35 Tapping screws. Refer to the drawing on the left in Fig. 4.  
(7) Assemble Fan 110 and Fan cover. Refer to Fig. 2.  
And then, set Carbon brush. Refer to Fig. 3.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 7/ 8  
Circuit diagram  
Fig. D-1  
Color index of lead wires' sheath  
Black  
White  
Blue  
Brown  
Lead wire (white or blue) of Power supply  
cord connected to P2 terminal  
Lead wire (black or brown) of Power supply  
cord connected to P1 terminal  
Switch  
Note: Noise suppressor and Line filter are not  
used for some countries.  
viewed from Commutator side  
Noise  
suppressor  
Line filter  
Brush  
holder A  
Field  
Power supply cord  
Brush  
holder B  
Wiring diagram  
Fig. D-2  
Wiring of Field lead wires  
1. Mount Filed to Motor housing complete as shown below.  
2. Route Field lead wires through the slit  
and Lead wire holder as shown below.  
connected to  
Switch  
Field  
connected to  
Switch  
Slit  
Lead wire  
holder  
Field lead wires  
Motor housing  
complete  
Download from Www.Somanuals.com. All Manuals Search And Download.  
P 8/ 8  
Wiring diagram  
Fig. D-3  
Switch  
Motor housing  
complete  
Noise suppressor  
(if used)  
Field  
Lead wire  
holder  
Power supply  
cord  
See the drawing  
on the right in Fig. D-2.  
Line filter (if used)  
Set Line filter with Field lead wires  
between Lead wire holders.  
1. Pass Field lead wires through Line filter  
and wind them one turn and pass them  
again as shown below.  
2. Winded Filed lead wires have to be located on  
the Motor housing complete side.  
Motor housing complete  
Line filter  
Winded Field  
lead wires  
Field lead wires  
Field side  
Handle cover  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Krown Manufacturing Answering Machine KVT100 User Manual
Leica GPS Receiver GSI16 User Manual
Life Fitness Bicycle 95RWEZ User Manual
LOREX Technology Flat Panel Television L15LD400 User Manual
Magnavox CRT Television 19PR15C User Manual
Marshall electronic Musical Instrument Amplifier MC 0105 User Manual
Maytag Clothes Dryer W10151609A User Manual
McCulloch Lawn Mower M3750SM User Manual
Mellerware Beverage Dispenser BDM001 User Manual
Midland Radio Marine Radio MO 4128 User Manual