MAX Computer
Operator's Guide
Copyright 2005
JMI Telescopes
Jim's Mobile, Incorporated
8550 West 14th Avenue
Lakewood, CO 80215
U.S.A.
Phone (303) 233-5353
Fax (303) 233-5359
Order Line (800) 247-0304
Web Site jmitelescopes.com
Email [email protected]
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
INTRODUCTION............................................................................................................. 4
What is Does................................................................................................... 4
What it Doesn't Do .......................................................................................... 4
GETTING STARTED ...................................................................................................... 4
Encoder Test........................................................................................................... 4
Troubleshooting ...................................................................................................... 5
USING YOUR COMPUTER............................................................................................ 7
ALIGN STAR or STAR FIX...................................................................................... 7
RA DEC................................................................................................................... 8
CATALOG............................................................................................................... 8
NEW Catalog .................................................................................................. 8
PLANETS........................................................................................................ 9
GUIDE..................................................................................................................... 9
IDENTIFY................................................................................................................ 9
ALIGN ................................................................................................................... 10
Subsequent Alignments ................................................................................ 10
TIMER................................................................................................................... 10
ENCODER ............................................................................................................ 11
POLAR.................................................................................................................. 11
SETUP or INSTALL .............................................................................................. 11
About SET DEC=0, LEVEL ME, and VERTICAL .......................................... 12
Appendices
A. Specifications ....................................................................................................... 13
B. NS/DS Catalog Abbreviations.............................................................................. 14
C. RS-232 Cable Assembly....................................................................................... 14
D. Sample BASIC Program Listing .......................................................................... 15
E. Quick-Start Guide ..................................................................................Back Cover
Download from Www.Somanuals.com. All Manuals Search And Download.
accomplish this task. (Some "Go To" telescopes can be
software controlled using the SGT-MAX system.)
INTRODUCTION
This manual covers the NGC-MAX, NGC-miniMAX and
NGC-microMAX computer units. Sections which cover
material not common to all of these units are labeled with
the models they apply to.
GETTING STARTED
The first step in preparing to use your MAX computer is to
install the optical encoders onto the axes of your telescope.
If purchased with one or more sets of encoder mountings
from JMI, will find a separate Encoder Installation sheet
which covers the installation process required for your
specific mount. Most of these installations require no
drilling or tapping and can be installed in approximately 15-
20 minutes.
The MAX family of computers are revolutionary,
computerized digital setting circle units with an internal
database of hundreds to thousands of astronomical objects.
After a simple alignment process (pointing your telescope at
any two celestial objects, such as bright stars), the
computer will operate as a high-resolution, real-time display
of the Right Ascension and Declination of your telescope.
Due to the internal database of galaxies, clusters, nebulae,
stars, quasars, black holes and planets, the computer can
quickly guide both the novice and expert viewer alike to
almost any object desired. Instead of spending the majority
of your viewing session attempting to locate objects, you
can now be guided from object to object in seconds!
After the encoders have been mounted, a test should be
performed to confirm proper installation and function of
each of the two encoders, as well as the setup information
within the MAX computer. (When purchased with a set of
encoder mountings, the MAX computer is pre-programmed
with the necessary information to work with your specific
mount, so you should not need to concern yourself with this
aspect yet. For further information on this topic, see
SETUP on page 11.)
The MAX computer utilizes an 8-character (16 on the NGC-
MAX) dot-matrix LED display with brightness control and
four large push-buttons for the user-interface. All functions,
including selection of any one of the internal objects, can be
accomplished easily in a matter of seconds with very little
practice. After a brief familiarization period, most users will
be able to perform all operations by touch.
Encoder Test
Plug the common end of the encoder cable into the MAX
computer and each of the opposite two ends into its
appropriate encoder (the Encoder Installation sheet
indicates which end is for each encoder). Place the MAX
computer unit in its holding tray or on a stable surface out of
the way of the telescope's motion. The unit should be
turned off at this time.
The NGC-MAX's serial interface allows communication with
external devices, opening the door to almost endless
possibilities. One application of this technology is our
popular SGT-MAX setup. This system allows users with a
personal computer to install a real-time link between their
telescope and desktop planetarium software, such as
THESKY™ by Software Bisque.
Point your telescope at the zenith (directly overhead). Now
turn the MAX computer on. After the version number is
briefly shown, use the brightness button (found to the right
of the ON/OFF switch) to set the display brightness as
desired.
What it Does
The MAX computer will guide the user to celestial objects
by indicating the direction and angular separation for each
axis of the telescope mount. When guiding to the Orion
Nebula, the display might show the following:
Press the DOWN button until ENCODERis displayed, then
press ENTER. The display should now show one of the
following:
M042 59→ 51↑
To break this down, M042 represents Messier catalog
number 42 (the designation for the Great Orion Nebula),
59→ indicates the object is 59° to the right, and 51↑
indicates the object is 51° up. As the telescope is moved in
the directions indicated, these numbers will decrease
toward zero, at which point the telescope is pointed at the
desired object.
NGC-MAX
NGC-miniMAX/microMAX
ER=000 ED=+000 000 +000
ER=000 ED=+090 000 +090
AZ=000 AL=+000
What it Doesn't Do
AZ=000 AL=+090
The MAX computer cannot physically move the telescope.
The user will normally need to move the telescope by hand,
although some telescopes have slewing motors which can
Note exactly where your telescope is pointed relative to
your mount (mechanical setting circles make this easier), as
Page 4
Download from Www.Somanuals.com. All Manuals Search And Download.
you will want to be able to reliably return to this same
position in a future step.
Troubleshooting Guide
Begin rotating your telescope in its Right Ascension or
Azimuth axis (left-to-right) in a clockwise direction as seen
from a vantage point directly above the telescope.
(Southern Hemisphere users should rotate in the opposite
direction.) The first set of displayed digits should increase
as the telescope is moved (you will see something similar to
000... 001... 002... 003, etc.). If the digits decrease
instead, see the troubleshooting guide for help.
Symptom
Possible Cause(s)
The unit does not come on. • Low battery (use only
alkaline batteries)
The display does not reflect • Mechanical slippage
the motion of one or both
encoders.
• Incorrect encoder setup
• Bad encoder/cable
If possible, continue rotating the telescope through a full
360° circle. Verify the accuracy of the display by comparing
it with the number of degrees you have moved in Right
Ascension or Azimuth. At 360° you will see 359 or 0.
Return the telescope to its starting point by rotating counter-
clockwise. At this point the digits should return to 000. If
instead they vary from zero by more than plus or minus 1,
see the troubleshooting guide for help.
One or both encoders
appear to run in the opposite • Incorrect encoder setup
direction.
• Reverse mounting
• "Hung" German mount
Moving telescope in one
axis changes opposite
encoder reading.
• Swapped encoder cables
• Not polar aligned
Bad warp factors, inaccurate • Incorrect encoder setup
Now rotate the telescope in Declination or Altitude (up-and -
down) from the zenith toward the Southern horizon. The
second set of digits should decrease (Note: an apparently
increasing value is actually decreasing if the sign is
negative). If the digits increase instead, then see the
troubleshooting guide for help.
operation.
• Incorrect initialization
• Not polar aligned
• Slew rate exceeded
• Bad encoder/cable
• Low battery
Display shows ENCODER
ERRORat times.
If possible, continue rotating the telescope through a full
circle. Return the telescope to its starting point by rotating
in the opposite direction. At this point the digits should
return to their original 000 or 090. If instead they vary
from the original value by more than plus or minus 1, then
see the troubleshooting guide for help.
Mechanical slippage. Verify that all appropriate
setscrews and bolts are tight. Any gears or belts should not
have slop (you should not be able to rotate the encoder
shaft without turning the telescope — a belt does not need
to be very tight to meet this criteria). You might want to
mark the encoder shaft to determine if it rotates with the
telescope as it should.
If you encountered no problems, continue on to the next
section, USING YOUR COMPUTER.
Incorrect encoder setup. Since the computer can be
used with various encoder resolutions and gearing ratios,
the software allows the definition of the resolution for both
axes. If this value is set improperly, the result can be
slightly to grossly inaccurate performance, and if set to zero,
can make an encoder appear to be non-functional.
Troubleshooting
Use the Troubleshooting Guide (below) to find possible
causes then read the sections below for possible solutions.
For a more in-depth troubleshooting guide, see the
addendum Diagnosing MAX Computer System Problems.
A separate sheet titled JMI Encoder Setup Sheet — Tics-
Per-Revolution, included with your encoder mountings, lists
the correct setup to use with your specific mount. Confirm
that the MAX computer setup matches this sheet paying
particular attention to the order and sign of each tics-per-
revolution specification (see SETUP on page 11 for
additional help).
Low battery. The MAX computer can be powered from
any 7-15 volt DC (direct current) source. When the power
supply is below about 6.5 volts, the display will flash
ENCODER ERROR.
If using an internal 9 volt battery, be sure that it is alkaline
("Alkaline" must appear on the battery casing). Due to
potentially rapid voltage and current drops in other battery
designs, they should not be used. This includes nickel-
cadmium (NiCd) rechargeable batteries as well as carbon-
zinc batteries).
Reverse mounting. If an encoder is running the
improper direction, the simplest solution is to change the
sign of that encoder's resolution as found in the setup (see
SETUP on page 11). This should only become necessary if
the encoder has been mounted in a manner contrary to that
which was intended by the Encoder Installation sheet, or if
the encoder installation is custom designed by the user.
Page 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Alternatively, the encoder can sometimes be re-mounted so
that it turns the opposite direction.
Swapped encoder cables. The Encoder Installation
sheet included with the encoder mountings should detail
exactly which encoder cable is for each axis. As a general
rule, on equatorial mounts the Declination encoder cable is
the longer of the two, and on Altitude/Azimuth mounts the
Azimuth cable is longer.
Bad encoder/cable. While the probability of an
encoder or cable being bad is extremely small, it is a
possibility. If the problem is isolated to either the cable or
encoder, there are a few simple tests which can quickly
determine the exact culprit. Follow each point as outlined
below, checking the operation of the encoders after each
until the problem disappears.
Not polar aligned. This is not a true problem as the
MAX computer works very well even if the mount is 90°
from polar aligned. However, there are symptoms of which
the user should be aware.
1. Confirm that all three ends of the encoder cable are
securely connected. If visible, inspect each of the four wires
at the encoder pins to check for a loose or intermittent
connection (it is normal for one of the second-to-outside
pins to have no connection).
First, do not use the EP or GP mount setting unless your
mount is accurately polar aligned, or you intend to use the
POLARmode to assist in polar alignment. Please note that
the EP/GP settings assume a perfectly polar aligned mount
— most pointing errors when using these settings are due
to an inaccurate polar alignment.
2. Swap the two encoder ends of the encoder cable so that
the Right Ascension/Azimuth cable is plugged into the
Declination/Altitude encoder and vice-versa.
Second, a clock drive (Right Ascension motor) cannot
properly track the stars if the telescope mount is not polar
aligned — stars and other objects will appear to drift out of
the eyepiece, requiring regular re-positioning. In other
words, the closer your mount is to polar alignment the
longer an object will stay in view without manual
adjustments.
3. If the symptom is still present on the same displayed axis
after step 2, then the problem is in the encoder cable.
Remove the cable from the problem axis and check the wire
for damage and the cable's plug to see that all four golden
metal plates have been pressed down evenly. If necessary,
compare it with the other encoder plug. If one or more of
these plates is high, you may try to press it down carefully
with a small flat-head screwdriver or similar tool. If this
cannot be done, the cable should be replaced.
Third (and the cause of misplaced concern among some
new users of units such as the MAX computer), is the
simultaneous change of both Right Ascension and
Declination as seen under the RA DEC display when
moving only one axis of the telescope. This is not an error
as the MAX computer is simply reporting the telescope's
true Right Ascension and Declination. What is commonly
overlooked is the fact that a non-polar aligned mount is
always moving through both Right Ascension and
Declination when either of its two axes is rotated.
4. If the symptom switches axes after step 2, then the
problem is at the encoder. Remove the encoder cable
connector and visually inspect the jack on the encoder. The
four golden wires inside should be roughly even, although
they might be staggered high-low-high-low. If any of the
wires appears to be bent at an odd angle or pressed down
too much, this could be the problem. The jack may need to
be replaced.
Incorrect initialization. A common problem is that of
ignoring or misunderstanding the initial pointing instruction
from the MAX computer at power up (e.g. SET DEC=0,
LEVEL ME, and VERTICAL). If you have set up the
MAX computer for a polar aligned telescope (EP or GP),
then you do not need to concern yourself with this aspect,
although it might be a good idea to be familiar with it. See
SETUP on page 11 for more information.
"Hung" German mount. (German equatorial mount
users only). Because of the design of these mounts, it is
possible to point the telescope at the same location from
two quite different positions. To visualize this, point the
telescope at 0° Declination. Now rotate the telescope 180°
in each axis, avoiding the base as necessary. The
telescope is on the opposite side of the mount head, yet
pointing in the same direction.
Slew rate exceeded. The MAX computer has a
maximum rate at which the encoders can be rotated. Due
to the frequency at which the computer samples the
encoders, they can be rotated faster than the computer can
accept the data. The maximum speed depends on the
number of tics per telescope axis rotation and the sampling
rate. While it is unlikely that you will spin your telescope
through a large arc fast enough to exceed this speed, it can
be jolted a small amount in a very short interval causing a
loss of alignment. With smaller telescopes and higher total
encoder resolutions you will be more susceptible, but under
normal operation you should never exceed the limit.
This feature of the German mount is nice when an object is
located in a normally hard-to-view position, but it has the
added affect of changing the polarity of the Declination
encoder. For this reason, a unique stipulation is placed on
users of German mounts — when performing the encoder
test or an initial star alignment, the telescope tube must be
on the West side of the mount. (Southern Hemisphere
users should place the tube on the East side of their
mount.) Refer to the addendum titled Star Alignments with
a German Equatorial Mount for a complete description.
Page 6
Download from Www.Somanuals.com. All Manuals Search And Download.
alignment stars (chosen with the UP/DOWN buttons) and
then center that star in your telescope's eyepiece.
USING YOUR COMPUTER
If you wish to start using your MAX computer immediately
without reading through the manual, or you just want a
quick refresher course, please refer to the Quick-Start
Guide found in Appendix E.
With the chosen star centered as well as possible in your
telescope's eyepiece (not the finder scope), press the
ENTER button to align the MAX computer on that star.
Never use Polaris as an alignment star for an Equatorial
mount and never use a star near Zenith for an Alt/Az mount.
Any delay in pressing the ENTER button might allow the
star to drift slightly from center, thereby decreasing the
accuracy of your alignment — try to keep this delay as small
as possible, with five seconds or less being about right. For
increased accuracy during the alignment process, it is
recommended that a short focal length (high power)
eyepiece be used.
The MAX computer has several modes, or applications to
enhance your observing time. Below is a list of the modes
available:
NGC-MAX, NGC-miniMAX and NGC-microMAX
ALIGN STARor STAR FIX
RA DEC
CATALOG
GUIDE
ALIGN
ENCODER
If you should accidentally press the ENTER button and align
the MAX computer before you had the star centered in your
eyepiece, you will need to reset the unit by turning it off,
waiting five seconds, and then turning it back on.
SETUPor Install
When you press ENTER for the first alignment, the MAX
computer will briefly report a "warp" factor such as the
following:
NGC-MAX and NGC-miniMAX
TIMER
POLAR
WARP=- 0.2
NGC-MAX
If you are using either of the EP or GP mount settings,
which assume that the mount is perfectly polar aligned, the
warp value will show zero and you will be ready to begin
using the other features of the unit. If you are not using EP
or GP (see SETUP on page 11) then you should finish this
section before continuing.
IDENTIFY
Upon turning the unit on, you will see a brief message,
followed by ALIGN STAR or STAR FIX. (If instead
you see a message to point the telescope a particular
direction, you should do so if you plan to align the computer
with the sky.
See SETUP on page 11 for further
Since the telescope is not perfectly polar aligned (i.e. you
are not using the EP or GP mode), you will need to align on
one more star to complete the alignment procedure. For
best results, the second star should be between 60° and
120° distance from the first star. Simply repeat the initial
procedure of selecting a star name, pointing the scope to
that star, then pressing ENTER. (Note: for simplicity, the
method of aligning on two stars is presented here. In
reality, the user may choose to align on any two objects in
the MAX computer database, including the user definable
objects, via the ALIGNmode.)
information. When operating the unit apart from the
telescope, you may simply press ENTER at this point.)
Use the UP and DOWN buttons to scroll through the various
modes. Notice that either of these buttons pressed for more
than an instant will cause the options to scroll faster until the
button is released. Following is a detailed description of
each of these modes and how to use them. For reference,
the UP and DOWN buttons scroll through options (whether
choosing a mode, star name, catalog number or other
option), and the ENTER button selects the currently
displayed option. The MODE button is solely for returning
to the mode level to permit selection of a new mode.
Once again you will see a warp factor displayed. This
message is reporting how many degrees the telescope is
from where the MAX computer expected it to be when
pointing at your selected alignment object. This number
should be within plus or minus one-half degree of zero
(±0.5). Any value greater than this should be considered an
error indication. (It is possible to have a perfect warp factor
and still have very poor pointing accuracy if one or both of
the encoders is appearing to run the opposite direction. If
this is experienced, see the Troubleshooting Guide on page
5.)
It is recommended that the new user study each of the
following mode descriptions with the MAX computer in
hand.
ALIGN STAR or STAR FIX
Upon entering this mode, the display will read ALIGN
ACHERNAR or similar.
When connected to your
telescope's encoders, you would need to select one of the
If the warp factor is considerable, you should confirm that
Page 7
Download from Www.Somanuals.com. All Manuals Search And Download.
the star you are pointing at is indeed the one selected in the
MAX computer.
ST
Unique compilation of most of the brighter and
interesting stars (including many doubles)
Messier catalog (deep-sky)
M
For indoor familiarization, the alignment process may be
simulated to allow access to additional modes (attempting
to select some modes before the alignment process has
been completed will result in a STAR SIGHTINGS ARE
NGC
IC
Revised New General Catalog (deep-sky)
Index Catalog (deep-sky)
Planets Eight major planets and the Sun (alias "DATE")
NEW User-definable list of object coordinates
NS/DS Unique compilation of non-stellar, deep-sky
REQUIREDmessage).
objects.
The user definable list contains the coordinates of any
objects you wish, and can only be changed by writing new
information over the old. In other words, even without a
battery, the list is retained within the MAX computer until
you want to change it.
RA DEC
This mode displays the Right Ascension and Declination
(coordinates) of the direction the telescope is currently
pointed. By use of an internal sidereal clock, the MAX
computer will work properly with or without a clock drive
running. This means that users not using a clock drive will
be able to watch the Right Ascension slowly increase with
time as the Earth rotates.
Upon entering the CATALOG mode, use the UP/DOWN
buttons to select which catalog you wish to use, and then
press ENTER. You will now be permitted to define the
specific catalog number (2-4 digits, depending on the
catalog) one digit at a time, or planet name. This is
accomplished through a process similar to setting a digital
watch. Use the UP/DOWN buttons to define each digit,
then ENTER to continue on to the next. If your desired
number is of fewer digits than requested, you will need to
use preceding zeros (e.g. - for M1 you would enter M001).
After ENTERing the last digit, the coordinates for that object
will be displayed, similar to the following:
The Right Ascension is displayed in the format HHMM
(hours and minutes) and the Declination is in the format
±DDTT (plus or minus degrees and tens of arc minutes).
Please note that the Declination is to tens of minutes, not
tenths of a degree (thus the digits 6-9 never appear in the
last column). With the telescope pointed at R.A. (Right
Ascension) 12 hours 36 minutes and Dec. (Declination) +26
degrees 42 minutes, the display would read:
M001 0534+220
NGC-MAX:
R=12h36 D=+26°42
With the exception of the planets and user defined (NEW)
objects, you may now press ENTER once more to see a
description of the object scroll across the screen. For our
above example, this would appear as follows:
miniMAX / microMAX: 1236+264
The MAX computer uses epoch 2000.0 coordinates.
Because the computer "sees" all stars and objects relative
to each other, rather than to an Earth-based coordinate
system, the Earth's precession is not a factor in the pointing
accuracy of the MAX computer. Only the reported R.A. and
Dec. are affected by precession, therefore any user defined
objects should be entered with epoch 2000.0 coordinates.
M001 MAG= 8.4 SIZE=5.8 CRAB
NEBULA SUPERNOVA REMNANT TAURUS
NEBULA SA=05
The descriptions fit a common format which is normally self-
explanatory. This format is: object catalog and number;
magnitude; size (in minutes unless followed by "); common
name (if applicable); constellation; object type; and Sky
Atlas 2000.0 or Uranometria chart number. The smaller
NGC-microMAX database does not include size,
constellation or type information.
The ENTER button can be pressed any time during the RA
DECmode to display a star chart number for that region of
sky. The NGC-MAX can display information for either the
Sky Atlas 2000.0 or Uranometria charts. The NGC-
miniMAX and NGC-microMAX units only display Sky Atlas
2000.0 chart numbers.
NEW Catalog
The coordinates for up to 28 user defined objects may be
entered into the MAX computer for later reference. This can
be used to store the positions of objects not found in the
other MAX computer catalogs (such as comets, asteroids
and variable stars). While it is possible to plan an evening's
viewing ahead of time and put the coordinates of each
object in the NEW catalog, it is recommended that the built-
in catalogs (M, NGC, etc.) be used whenever possible. This
is because the built-in catalogs store coordinates more
precisely than is allowable under the NEW catalog.
CATALOG
The MAX computers have several catalogs in memory:
Model
ST M NGC
IC P NEW NS/DS
NGC-microMAX 90 110
NGC-miniMAX
NGC-MAX
28
28
28
17
86
386
80 110 2745 960 9
928 110 7840 2852 9
Page 8
Download from Www.Somanuals.com. All Manuals Search And Download.
than ten degrees, that angle will be displayed to tenths of a
degree. If the telescope in our example had been moved
down 21.7 degrees, the display would now read:
To add an object to the NEW catalog, enter the CATALOG
mode and use the UP/DOWN buttons until NEW01 is
displayed. After pressing ENTER, select the object number
you wish to modify (01-28). Once you have ENTERed the
number, the current coordinates are displayed (if defining
for the first time, 2400-000will appear). Press ENTER
once more and the first digit of the Right Ascension will
begin flashing. Define the new coordinates one digit at a
time, until the last is entered (if the Declination is three
digits, the last is tens of arc minutes, not tenths of a
degree). The display will stop flashing, and at this point you
should review your coordinates to be sure they are correct.
If you need to change them, simply press ENTER and
repeat the process. When the coordinates are correct,
press the MODE button to have the MAX computer store
them in its memory.
NGC4565 171← 6↓3
Notice that the direction-indicating arrow (↓) has moved
between the 6 and 3 to double as a decimal point.
While entirely up to the user, it is probably easiest to move
one axis of the telescope mount at a time, rather than both
simultaneously. When the telescope is at the correct
position, the display will show the following:
NGC4565 0♦0 0♦0
If the initial star sighting(s) were done properly, the object
should now appear in your telescope's eyepiece.
A
PLANETS (NGC-miniMAX and NGC-MAX)
moderate power eyepiece is recommended when using the
GUIDEmode, as the object is more likely to be within its
field of view than in that of a high power eyepiece.
Eyepieces yielding 1/4° to 1/2° field of view work best. (If
you don't know the field of view of your eyepieces, try
finding one which just fits the full moon into the field.)
Upon ENTERing the PLANETS catalog, DATEwill flash on
the display. Before selecting a planet for the first time in a
viewing session, the current date should be set. For the
most accurate guiding, use the current date for Greenwich,
England (i.e. set the date based on Universal Time).
To set the date, press ENTER while DATE is flashing.
(The coordinates shown are those of the Sun for the last
defined date. This may be useful for daytime alignments,
however, you should take proper precautions when pointing
your telescope near the Sun!) Press ENTER again, and
you will see a display similar to the following:
IDENTIFY (NGC-MAX only)
If you are looking at an object you cannot identify, this mode
will let the NGC-MAX try to identify it for you. Additionally,
you might simply wish to point your telescope to an
unfamiliar part of the sky and have the computer find nearby
objects of interest.
DATE 12-31-2000
You may use the UP/DOWN and ENTER buttons to define
the current date in the format MM-DD-YYYY. This setting is
stored in non-volatile RAM, so if the unit is turned off the
date will not be lost. The MAX computer does not update
this setting with the passage of time (whether on or off), so
it will be necessary to update it if the unit is used to locate
planets at a later date.
In either case, the NGC-MAX will search its databases for
the object nearest the telescope's current position. The
search can be performed regardless of object type, or
limited to a specific type, such as planetary nebulae.
A
limiting magnitude is also entered to eliminate objects from
the search which might be too faint for the observer's
circumstances.
Once the date is defined, use the UP and DOWN buttons to
select a desired planet.
Upon entering the IDENTIFYmode, you are allowed to
specify which type of object you wish to find. This type can
be any of the following:
GUIDE
R (red star)
2 (double star)
NB(nebula)
PN(planetary nebula) QSR(quasar)
GX(galaxy)
GC(globular cluster)
ST(star)
BK(black hole candidate)
After selecting a desired object under CATALOG, entering
GUIDEmode will show you how far to move the telescope
in each axis to find that object. Following is an example
display:
NS(any non-stellar)*
ANY(any of above)
OC(open cluster)
NGC4565 171← 29↓
* The NS type is used to find a non-stellar object from any
catalog, and should not be confused with the NS catalog.
This indicates that the telescope should be moved to the left
171° and down 29° to locate NGC4565. As the telescope is
moved, the display updates the angles and changes
directions if the object is passed. When an angle is less
After the type is ENTERed, use the UP/DOWN buttons to
set the limiting magnitude as desired. If you enter a value
Page 9
Download from Www.Somanuals.com. All Manuals Search And Download.
of eight, then only objects of magnitude 8.0 or brighter will
be found. The limiting magnitude range is from one (bright)
to 17 (faint). Those objects which do not have a magnitude
defined are only found with a limit of 17.
the angular separation of the alignment positions is
essentially equal to the separation of the objects. Note the
distinction between alignments and objects. Relative to the
Earth, an object's position is changing with time, however
the alignment positions remain fixed.
When both search parameters have been defined, press
ENTER and the computer will display the name of the
nearest object meeting your search criteria. Because the
display is updated every few seconds to indicate the
nearest object at that instant, you may move the telescope
until an object you wish to observe is shown. Pressing
ENTER will scroll the information available on the object.
Any time a subsequent alignment is made, pointing
accuracy in the neighboring region should be improved.
However, it is possible for such an alignment to decrease
pointing accuracy elsewhere, even to an extent worse than
that observed prior to the new alignment.
When a new alignment is made, one of the previous two
alignment positions — that which is least desirable relative
to the new — is discarded. Therefore, the angle of
separation between the remaining previous alignment
position and that of the new alignment becomes the critical
factor. If this angle is too small or too great, the overall
pointing accuracy will degrade.
When no object fits the search parameters, the first item in
the catalog is displayed (e.g. FOUND NGC0001).
ALIGN
This is similar to the ALIGN STARmode, except that an
alignment may be done on any object in the MAX computer
catalogs. This includes the planets and user defined
objects.
For the average user, this should not be a noticeable
problem, but if you should experience degraded accuracy, it
can probably be eliminated by following these steps in
selecting subsequent alignment objects:
1. Recall the positions of your last two alignment objects,
relative to the Earth (these are not their current positions).
The object used for the ALIGNmode is that last displayed
in the ALIGN STAR, CATALOGor IDENTIFYmodes.
Use one of these modes if you wish to select a different
object.
2. Try to make your subsequent alignment on an object
which is as close to 90° (±30°) from either one of your last
two alignment positions as possible.
The ALIGN mode can be used in place of, or in
conjunction with the ALIGN STAR mode to meet the
initial alignment requirements, as well as for subsequent
alignments, as outlined below.
This process will maintain maximum pointing accuracy and
should be followed with each subsequent alignment.
Subsequent Alignments
TIMER (NGC-miniMAX and NGC-MAX)
If, in the course of an evening's viewing, you find that the
accuracy of guiding has decreased, you may re-align the
telescope on an additional object to restore this accuracy.
Such a situation is normally caused by inaccuracies in the
manufacture of the telescope's mount, affecting its
orthogonality (meaning all axes are perpendicular). This
introduces a pointing error when moving the telescope from
one side of the sky to the other. The MAX computer
assumes a perfectly orthogonal mount for its calculations.
This is a 24 hour event timer which displays to the second.
Possible uses for this mode include recording elapsed time
between occultation contacts or other astronomical
phenomena, and exposure times for astrophotography.
Upon entering this mode, the display will read:
00 00 00.0
If your mount is very close to being orthogonal, you will
probably never see such an error, and should not need to
make additional alignments. If, however, you do wish to
make an alignment subsequent to the initial two required,
you should keep the following in mind. (This does not apply
to users of the EP or GP settings.)
(Tenths of a second are not displayed on the NGC-
miniMAX.)
While in this mode, use the MODE and ENTER buttons as
follows:
MODE
This will exit the timer mode, permitting another
mode to be chosen. The timer will continue in
the background, so that returning to this mode
will accurately show the current elapsed time.
When making alignments, the MAX computer "sees" all
such locations in terms of an Earth-based reference. In
other words, the altitude and azimuth of an object, at the
time of its alignment, determines its angular separation from
another alignment object.
ENTER
This button cycles through a series of three
functions: START, STOP, and RESET.
Of course, if alignments are done near to each other in time,
Page 10
Download from Www.Somanuals.com. All Manuals Search And Download.
This indicates the direction and distance to Polaris. You
should now move your telescope to the indicated position
just like under GUIDE mode. When you have zeroed both
angles, your display should look like this:
The timer is started by pressing the ENTER button, which
will temporarily cause the display to show the following:
START
POLARIS 0♦0 0♦0
The elapsed time from the moment you pressed the ENTER
button will then be displayed until you press ENTER to stop
the timer or MODE to exit the timer mode.
If your mount is polar aligned, Polaris will appear near the
center of a moderately powered eyepiece. (Don't worry
about the offset of Polaris from the actual pole — the MAX
computer is accounting for this.*) If Polaris is not near the
center of your eyepiece, you will need to adjust the altitude
and azimuth adjustments of your mount until Polaris is
centered in your eyepiece. Be sure not to move your
telescope relative to your mount — the computer's display
should remain as shown above. If you should accidentally
move the telescope itself, you can zero the angles again so
that the display does match that above.
ENCODER
This mode is primarily used for verifying proper operation of
the encoders. The encoder angles (in whole degrees)
relative to their startup positions is shown. For equatorial
mounts, the first axis is Right Ascension and the second
Declination; for Alt/Az mounts, the first axis is Azimuth, the
second Altitude.
Now press the ENTER button, and you will briefly see a
reminder to adjust your altitude and azimuth, then a display
similar to this:
For more information on using this mode to test the
performance of your encoders, see the Encoder Test
section beginning on page 4.
SIGHT PROCYON
You should now point your telescope back at your reference
star and center it in the eyepiece. Press ENTER and you
will be instructed to guide back to Polaris. Repeat the
above process from this point as many times as desired.
With each iteration of the process, your telescope's polar
alignment should become more and more accurate. Two or
three iterations should be sufficient for most visual work,
while up to five or six iterations may be required for long-
exposure photographic work.
POLAR (NGC-miniMAX and NGC-MAX)
Although the MAX computer can be used without it, having
your telescope polar aligned is desirable in many cases.
The accuracy of a clock drive depends upon this alignment
for visual and especially photographic purposes. The
POLAR mode is used to achieve a highly accurate polar
alignment.
Users installing a mount permanently will find this procedure
helpful for obtaining an accurate polar alignment, however
one of the more time-consuming methods (star drift or
photographic) should be used for fine tuning.
Before using this mode, you must change your setup to
reflect either an EP (Equatorial - Polar aligned), or GP
(German - Polar aligned) mount. See SETUP, below, for
help on doing this. If you do not do so, upon attempting to
enter this mode nothing will happen or you will see:
* While your telescope's optical tube is being aligned on
Polaris, the mount's polar axis is actually being aligned on
the pole, not Polaris.
ONLY FOR EP GP
Once you have ENTERed the POLAR ALIGNmode, use
the UP and DOWN buttons to choose a reference star by
name from the list of 30 to 40. The star you choose should
be between 60º and 120º from the pole — with those near
the celestial equator being best. Do not press any more
buttons yet.
SETUP or INSTALL
This mode is used to tell the MAX computer some
characteristics of your mount. The meaning of each of the
setup parameters is defined here.
The first display,
showing the selected mount type, will be similar to the
following:
With your mount at least roughly on the pole (the closer you
are to begin with, the faster the process), point the
telescope at your chosen star and press ENTER once it is
in the center of your eyepiece. A bright asterisk (*) may
momentarily appear, followed by a display similar to the
following:
SCOPE EQ
Mount. This setting informs the MAX computer of the
type of mount your telescope is on. The six types to choose
from are AZ, AV, EQ, EP, GQ, and GP (the NGC-
POLARIS 77← 83↓
Page 11
Download from Www.Somanuals.com. All Manuals Search And Download.
microMAX does not have the EP or GP settings). These
represent the following:
correct values to use for your telescope mount. If you
purchased your encoders with the MAX computer, the
resolutions are already defined for your mount.
AV Alt/az Vertical. For use with altitude/azimuth mounts
initialized to a vertical* position.
Under this setup, the first value is that of the Right
Ascension, or Azimuth encoder. The second value is that of
the Declination, or Altitude encoder. The correct resolution
is that of the encoder multiplied by the number of turns it
makes each time the telescope axis is rotated. For
example, an encoder with a resolution of 5000 tics, when
geared 2:1, yields an effective resolution of 10000.
AZ Alt/az Zero. For use with altitude/azimuth mounts
initialized to a level* (or 0°) position.
EQ EQuatorial. For equatorial mounts using a two-star
alignment. This must be used if you have a non-polar
aligned, non-German, equatorial mount.
SET DEC=0, LEVEL ME, and VERTICAL
For non-polar aligned telescopes, or polar aligned
telescopes using the two-star alignment method, the only
case in which you can ignore the initial pointing instruction
is when the MAX computer will not be used for actual
viewing (such as when conducting the Encoder Test). At all
other times, this step is vital to proper performance, and can
greatly affect the accuracy of the unit (either beneficially or
detrimentally). None of the above messages will appear if
the MAX computer is set for use with a polar aligned
telescope.
EP Equatorial Perfect. Only for use with a non-German,
equatorial mount which will be used in a perfectly
polar aligned configuration.
ET Equatorial Table. For use with a mount whose
tracking motion is not apparent to the encoders (such
as an altitude/azimuth mount utilizing a tracking
platform). In this mode, the MAX computer assumes
that the telescope is being driven at exactly sidereal
rate, however it does not require that the mount be
polar aligned.
When the initial pointing instruction is displayed
(immediately after the power-up version message), no
button on the MAX computer should be pressed until that
positional requirement has been met. This initial position
tells the computer where your two encoder axes are
perpendicular (or parallel) to each other. This point is not
affected by polar aligning or leveling, so it does not matter
how your mount is oriented relative to the Earth or sky.
GQ German EQuatorial.
Used with non-fork type
equatorial mounts. If the telescope can be pointed in
the same direction from two unique positions (as with
German mounts), the computer assumes one of
these positions.
Refer to the addendum "Star Alignments with a
German Equatorial Mount" for further information.
The meaning of each of the three possible messages is
outlined here:
GP German Perfect. Used with non-fork type equatorial
mounts which will be used in a perfectly polar aligned
configuration.
SET DEC=0or LEVEL ME
The telescope should be pointed with the tube
Refer to the addendum Star Alignments with a
German Equatorial Mount for further information.
perpendicular to the polar/azimuth axis.
A
Declination setting circle, if set properly, may be
used to find this point.
* See the separate addendum The Importance of the Initial
NGC Alignment for details.
VERTICAL
The telescope should be pointed with the tube
parallel to the polar/azimuth axis. A Declination
setting circle, if set properly, may be used to
find this point.
Scroll Rate. This determines how fast the information on
objects is scrolled across the MAX computer display. The
default value (that set prior to shipment) is 5, with the range
being 0 (slowest) to 9 (fastest).
It should be noted that improving this initial alignment can
greatly increase the guiding accuracy without showing an
improvement in the warp factor (which only measures the
accuracy of the distance between the two alignment stars).
Since factory marks are often off by a significant amount,
you may wish to do the following test. First, adjust the initial
position in one direction a few thousandths of an inch, finish
the alignment, then test the guiding accuracy. If it is worse,
try adjusting the initial alignment in the other direction. Do
several more adjustments in the direction that showed
improvement until you see the most accurate guiding. This
process is time consuming but well worth the effort.
Chart Reference. Whenever information on an object
is scrolled across the display, the last item shown is the
chart number on which that object can be found. With the
NGC-MAX you may select between two popular star
atlases: Sky Atlas 2000 or Uranometria. The appropriate
chart number will appear after "SA=" or "UA=" respectively.
Encoder Resolution. These values tell the MAX
computer what the final output resolutions of the encoders
are. A separate sheet, JMI Encoder Setup Specifications,
which was included with your encoders, specifies the
Page 12
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A — Specifications
NGC-MAX
NGC-miniMAX*
NGC-microMAX
Size:
14.6cm x 9.1cm x 3.7cm (5.75"
x 3.60" x 1.44")
7.0cm x 11.7cm x 3.0cm
(2.75" x 4.60" x 1.18")
6.1cm x 9.9cm x 3.0cm
(2.40" x 3.88" x 1.18")
Weight:
233g (8.2 oz.)
155g (5.4 oz.)
122g (4.3 oz.)
Temperature:
Display:
-10°C to +50°C (14°F to 122°F)
-10°C to +50°C (14°F to 122°F)
-10°C to +50°C (14°F to 122°F)
16 character, 5x5 dot matrix red
LED (four brightness levels)
8 character, 5x5 dot matrix red
LED (four brightness levels)
8 character, 5x5 dot matrix red
LED (four brightness levels)
Coordinates:
Sensors:
Epoch AD 2000.0
Epoch AD 2000.0
Epoch AD 2000.0
Two high-resolution, shaft- type,
incremental optical encoders
Two high-resolution, shaft- type,
incremental optical encoders
Two high-resolution, shaft- type,
incremental optical encoders
Sampling rate:
Database:
2.5KHz (2500 samples/sec)
1.95KHz (1950 samples/sec)
2.5KHz (2500 samples/sec)
9 Planets (including Sun)
28 User definable
110 Messier
9 Planets (including Sun)
28 User definable
80 Stars
17 Non-stellar/deep-sky
28 User definable
90 Stars
386 Non-stellar/deep-sky
928 Stars
86 Non-stellar/deep-sky
110 Messier
110 Messier
2852 IC
960 IC
7840 NGC
2745 NGC
12153 Total object count
12047 Non-duplicated
4018 Total object count
3912 Non-duplicated
245 Total object count
245 Non-duplicated
Modes:
ALIGN STAR
RA DEC
CATALOG
GUIDE
STAR FIX (ALIGN STAR)
RA DEC
CATALOG
GUIDE
STAR FIX (ALIGN STAR)
RA DEC
CATALOG
GUIDE
ALIGN
ALIGN
ALIGN
ENCODER
SETUP
ENCODER
SETUP
ENCODER
INSTALL (SETUP)
TIMER
TIMER
POLAR
POLAR
IDENTIFY
Power:
6.5 to 15 volts DC
6.5 to 15 volts DC
6.5 to 15 volts DC
17mA, display fully dim
60mA, display fully bright
(reverse polarity protected)
17mA, display fully dim
45mA, display fully bright
(reverse polarity protected)
14mA, display fully dim
44mA, display fully bright
(reverse polarity protected)
Battery:
9 volt alkaline
9 volt alkaline
9 volt alkaline
(25 hour life with display fully
dimmed)
(25 hour life with display fully
dimmed)
(30 hour life with display fully
dimmed)
* Discontinued Product
Page 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B — NS/DS Catalog Abbreviations
AB Abell
AN Antalova
CZ Czernik
DD Dolidze-Dzimselejsvili
DO Dolidze
FR Frolov
GU Gum
MA Markarian
ME Melotte
MF Maffei
MK Minkowski
MR Merrill
SP Stephenson
ST Stock
TO Tombaugh
TR Trumpler
TZ Terzian
B
Barnard
BA Basel
BD Baade
BI
Biur
H
Harvard
NE New
U
Upsala
BK Berkley
BL Blanco
BO Bochum
CE Cederblad
CR Colinder
HA Haffner
HB Hubble
HU Humason
PA Palomar
VB Van Den Burgh
PI
Pismis
RO Roslund
RU Ruprecht
SH2 Sharpless
KI
King
LY Lynza
Appendix C — RS-232 Cable Assembly
The NGC-MAX computer unit has an RS-232 serial port which may be used to provide encoder position information to a
personal computer (PC). This can be used with the sample BASIC program provided in Appendix D, or with a commercial
software program which supports the NGC-MAX protocol (such as Software Bisque's THESKY™).
A special cable is required between the NGC-MAX and your PC. You may use the information here to assemble your own
cable, or you may purchase one from JMI. While a 12 foot (3.6m) cable is standard, a custom length may be special
ordered.
The connector at the NGC-MAX side of the cable is an RJ11 or RJ12 phone-type plug using the center four contacts.
Reference the following diagram when inserting the wires from a flat 4-conductor cable:
YEL GRN RED BLK
Wire insertion end of RJ11 or RJ12 male connector
The connector at the PC can be one of three varieties, depending upon your PC. Check the size of the PC's serial, or COM
port connector which you plan to use with the NGC-MAX. On IBM-compatible systems, it should be a 9 or 25 pin male
connector with two rows of pins. On Macintosh systems, it will be a round 8 pin female connector.
Once you have determined the proper connector, use the appropriate pinout below to complete the cable.
9-socket D-subminiature (female)
25-socket D-subminiature (female)
8-pin mini-DIN (male)
2
3
5
YEL
GRN
RED
TX
RX
GND
2
3
7
GRN
YEL
RED
RX
TX
GND
3
4
5
8
GRN
RED
YEL
RX
GRN
TX
RED
GND
1
2
1 2 3 4 5
1 2 3 4 5 6 7 8 9 10 11 12 13
6 7 8 9
14 15 16 17 18 29 20 21 22 23 24 25
3
4
5
6
7
8
Solder side of connectors
Page 14
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix D — Sample BASIC Program Listing
The following program listing has been tested on numerous MS-DOS compatible computers using both GW-BASIC and Q-
BASIC. While all efforts have been made to ensure error-free code, the user is solely responsible for the accurate entry
and operation of this program.
100 '***************************************************************************
110 '** This BASIC program reads and displays encoder positions directly
120 '** from the RS-232C serial port of the JMI NGC-MAX v3.50 or later
130 '** Copyright 1996-2005 by Jim's Mobile Inc.
**
**
**
140 '***************************************************************************
150 ENC(1)=4096: 'Defines telescope Azm/RA encoder resolution
160 ENC(0)=4000: 'Defines telescope Alt/DEC encoder resolution
170 PORT$="COM1": 'Defines which serial port is connected to the NGC-MAX
180 CLS:PRINT "Make sure the NGC-MAX is on - then press the SPACE bar."
190 K$=INKEY$:IF K$="" THEN GOTO 190: 'Waits for user to press a key
200 IF K$=CHR$(27) THEN GOTO 370: 'If ESC is pressed, jumps to line 370
210 OPEN PORT$+":9600,N,8,1,RS,CS,DS" AS #3: 'Opens serial port
220 DEFP$="+00000"+CHR$(9)+"+00000": 'Defines the default position response
230 P$="":PRINT #3,"Q";: 'Asks NGC-MAX for encoder positions
240 K$=INKEY$:INPUT #3,P$: 'Reads keyboard/serial port
250 IF K$ = CHR$(27) THEN GOTO 370: 'If ESC is pressed, jumps to line 370
260 IF P$="" THEN GOTO 230: 'Waits for input from keyboard or serial port
270 IF LEN(P$)<8 THEN P$=DEFP$: 'If input not complete, sets to default
280 AZM$=LEFT$(P$,6): 'Extracts the Azimuth/R.A. encoder position
290 ALT$=MID$(P$,8,6): 'Extracts the Altitude/Dec. encoder position
300 A=-VAL(AZM$):GOSUB 400: 'Jumps to line 400 to interpret Azimuth angle
310 RA$=A$: 'Sets variable RA$ equal to the Azimuth angle
320 A=VAL(ALT$):GOSUB 400: 'Jumps to line 400 to interpret Altitude angle
330 DEC$=A$: 'Sets variable DEC$ equal to the Altitude angle
340 LOCATE 10,19:PRINT "Azm/R.A.= ";RA$: 'Displays the Azimuth/R.A. angle
350 LOCATE 10,46:PRINT "Alt/DEC.= ";DEC$: 'Displays the Altitude/Dec. angle
360 GOTO 230: 'Goes back to line 230 to check positions again
370 CLOSE #3:LOCATE 20:PRINT "Exiting program.": 'Closes the serial port
380 SYSTEM: 'and EXITS the program
390 '*** This subroutine changes the raw encoder data into angular form. ***
400 AX=(AX=0): 'Toggles variable AX to indicate which axis
410 A=A*360/ENC(-AX): 'Changes raw encoder tic value to an angle
420 IF A>359 THEN A=A-360:GOTO 420: 'Makes sure angle is less than 360
430 IF A<-359 THEN A=A+360:GOTO 430: 'Makes sure angle is greater than -360
440 IF NOT AX AND A>180 THEN A=A-360: 'Makes sure Altitude is within -180 to 180
450 IF A<0 AND AX THEN A=360+A: 'Makes sure Azimuth is greater than zero
460 A=A+.0051:A=INT(A*10000)/10000: 'Puts angle in a 2 decimal place format
470 S=SGN(A):A$="000"+MID$(STR$(A),2): 'Temporarily adds leading zeros
480 A=0:FOR X=1 TO LEN(A$): 'Starts looking for decimal place in angle
490 IF MID$(A$,X,1)="." THEN A=X: 'When decimal found, marks with variable A
500 NEXT X:IF A=0 THEN A$=A$+".0":A=LEN(A$)-2: 'Adds decimal value if absent
510 A$=MID$(A$,A-3,6): 'Extracts the angle in proper format
520 IF LEN(A$)<6 THEN A$=A$+"0": 'Makes sure second decimal place is present
530 S$="+":IF S<0 THEN S$="-": 'Sets the sign as plus or minus for angle
540 IF NOT AX THEN A$ = S$ + A$: 'Adds sign to the Altitude angle only
550 RETURN: 'Returns the program to line 310 or 330
Page 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix E — MAX Quick-Start Guide
NOTE: For best results, the following steps should be followed while using the telescope under actual observing conditions.
Simulated star alignments may be used for the purpose of familiarizing yourself with the operation of the computer, however, the
user should be aware that under these conditions the coordinate display and GUIDEmode will behave unpredictably.
1. Turn unit ON. A message will appear briefly.
2. Use the DIM button to set the brightness of the LED display as desired. If at any time during these steps a single, bright
asterisk (*) is shown on your display, it is an indication of an encoder error. It can also be indicated by the display showing
ENCODER ERROR. This can be caused by turning the telescope too rapidly or a bad electrical connection (including not
having the encoders plugged in).
3. If display shows:
Then do this:
DEC=0
Point your telescope such that the Declination setting circle is at the zero degree mark*.
Press the ENTER button and proceed to step 4.
MODE ALIGN STAR
The computer is set up for polar alignment. If the telescope is not polar aligned,
the POLAR ALIGNmode may be used as an aid to this end. Proceed to step 4.
or STAR FIX
VERTICAL
(Used with Altitude/Azimuth mounts)
Position the telescope tube such that it is pointed directly perpendicular to the bottom of
the rocker box*. Press the ENTER button and proceed to step 4.
LEVEL ME
(Used with Altitude/Azimuth mounts)
Position the telescope tube such that it is pointed exactly parallel with the bottom of the
rocker box*. Press the ENTER button and proceed to step 4.
* This initial setting needs to be as accurate as possible. The maximum tolerable error is one half of a degree. Any error larger
than this will result in poor pointing accuracy. Please see the addendum The Importance of the Initial NGC Alignment for
additional help on this setting.
4. Choose a bright star to use as an initial alignment. (Do not use Polaris with an Equatorial mount or a star at Zenith with an
Alt/Az mount.) After entering ALIGN STARor STAR FIXmode (by pressing ENTER when this is shown on the LED
display), use the UP and DOWN buttons to scroll through the star list until your chosen star's name is displayed.
5. With the star from step 4 centered in your telescope's eyepiece, press the ENTER button to align on the star. If a Wor WARP
value is shown, it may be ignored at this point (only the warps on alignments after the first have real meaning).
6. Repeat steps 4 and 5 using a second star which is at least 60 degrees from the first to complete the alignment procedure
(Polaris may be used for this alignment). At this point the warp value should be ±0.50 or less for accurate alignment.
7. To view an object, press the MODE button to enter the mode selection, and use the UP and DOWN buttons to locate the
CATALOGmode (this is two presses of the UP button from ALIGN STARor STAR FIX).
8. Press the ENTER button to select CATALOGmode. If you followed the above steps properly, the display will now show a
flashing STnext to a three digit number. This is indicating that you are currently working with the STar catalog, the number
being that of the alignment star from step 5.
9. To select an object, you must first define which catalog it is in. Use the UP and DOWN buttons to set the catalog
(ST=STARS, M=Messier, NGC=New General Catalog, IC=Index Catalog, NEW=User definable objects), then press ENTER.
10. You will now see the first digit of a 2-4 digit number flashing. Use the UP and DOWN buttons to select the first digit of the
catalog number you wish to observe. (If your catalog number is of fewer digits than that displayed, you must use preceding
zeros. For example, to enter M-42, your display would look like this: M042.)
11. With the first digit set, press ENTER and the second digit will be flashing. Continue this process until you have all digits set
as needed. Pressing ENTER once more will display the Right Ascension and Declination for that object.
12. If you would like to see the information which the MAX has on this object, press ENTER again. The display will scroll the
catalog number, magnitude, (size, common name, constellation), type of object, and Sky Atlas (SA) or Uranometria (UA) chart
reference.
13. Press the MODE button to return to mode selection. Press the UP button then ENTER to select GUIDEmode.
14. Displayed is the angular distance and direction to that object from the telescope's current location. The first angle is that of
Right Ascension/Azimuth, and has a left or right facing arrow to indicate direction. The second angle is that of
Declination/Altitude, and has an up or down facing arrow to indicate direction.
15. Moving the telescope in the direction indicated (one axis at a time if desired), the angles will decrease toward zero.
Whenever an angle is less than ten degrees, that angle is shown to tenths of a degree with the arrow doubling as a decimal
point. Zeroing both angles results in pointing the telescope at the selected object.
JMI Telescopes
Jim's Mobile, Inc. y 8550 W 14th Ave y Lakewood, CO 80215 y USA y 303-233-5353 y Fax 303-233-5359 y jmitelescopes.com
Download from Www.Somanuals.com. All Manuals Search And Download.
|